XO M30GC Wall Mount Chimney Range Hood Manuel utilisateur

Catégorie
Hottes
Taper
Manuel utilisateur

Ce manuel convient également à

I worked really hard
on this manual - so
please read it...
XOM WALL MOUNT
MODELS XOM30GC - XOM36GC
- 3 -
When buying any XO appliance
you can be confident you have chosen a
high quality, innovative and stylish product
from a company that cares about you!
If you require service or have questions,
there are 2 ways to contact our ventilation experts;
Online @ https://xoappliance.com/priority-service-for-your-xo-product/
Or by phone 973-403-8900
CONGRATULATIONS
on purchasing your XO.
Before you proceed, take just a
moment to register your XO at:
www.xoappliance.com/register-your-product/
REGISTRATION HELPS YOU BY -
Ensuring warranty coverage should you need service
Providing ownership verification for insurance purposes
Let’s XO notify you in the event of product changes or recalls.
- 4 -
It’s for your
own good...
Honest.
please read and follow
all safety instructions
where things are
GETTING READY
Safety and Precautions
Planning Ductwork
Install Examples
Dimensions
THE INSTALL
Mounting Height
Installing
Electrical Connections
MAINTENANCE
Filters
Cleaning
Recirculation
Light Replacement
OPERATING
The Push Button Controls
CCC Make Up Air Conversion
PARTS & WARRANTY
17 - 18
19 - 20
5 - 11
12 - 14
15 - 16
- 5 -
safety first
IMPORTANT SAFETY INSTRUCTIONS
FOR RESIDENTIAL USE ONLY
READ AND SAVE THESE INSTRUCTIONS
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
IMPORTANT: Save these Instructions for the Local Electrical Inspectors use.
INSTALLER: Please leave these Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
Take care when using cleaning agents or detergents.
Suitable for use in household cooking area.
WARNING - To reduce the risk of fire or electric shock, do not use this fan with any
Solid-State Speed Control Device.
CAUTION - To reduce risk of fire and to properly exhaust air, be sure to duct air out-
side – Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl
spaces, or garages.
CAUTION - For Residential Kitchen ventilating use only. Do not use to exhaust haz-
ardous or explosive materials and vapors.
CAUTION - To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
CAUTION - Please read specification label on product for further information and
requirements.
WARNINGTO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the manufacturer. If you have questions,
contact the manufacturer.
B. Before servicing or cleaning unit, switch power off at service panel and lock the ser-
vice disconnecting means to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked, securely fasten a promi-
nent warning device, such as a tag, to the service panel.
WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
A. Never leave surface units unattended at high settings. Boilovers cause smoking and
- 6 -
greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
B. Always turn hood ON when cooking with high heat.
C. Clean ventilating fans frequently. Grease should not be allowed to accumulate on
fan or filter.
D. Use proper pan size. Always use cookware appropriate for the size of the surface
element.
E. Keep fan, filters and grease laden surface clean.
F. Use high range setting on range only when necessary. Heat oil slowly on low to me-
dium setting.
G. Don’ t leave range unattended when cooking.
H. Always use cookware and utensils appropriate for the type and amount off food be-
ing prepared.
WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE
TOP GREASE FIRE, OBSERVE THE FOLLOWING:
A. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off
the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately,
EVACUATE AND CALL THE FIRE DEPARTMENT.
B. NEVER PICK UP A FLAMING PAN – You may be burned.
C. DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion
will result.
D. Use an extinguisher ONLY if:
1. You know you have a Class ABC extinguisher, and you already know how to operate it.
2. The fire is small and contained in the area where it started.
3. The fire department is being called.
4. You can fight the fire with your back to an exit.
aBased on “kitchen firesafety tips” published by NFPA.
Proper maintenance of the Range Hood will assure proper performance of the unit.
INSTALLATION INSTRUCTIONS
WARNINGTO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by qualified person(s) in accord-
ance with all applicable codes and standards, including fire-rated construction.
B. Sufficient air is needed for proper combustion and exhausting of gases through the
flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heat-
ing equipment manufacturers guideline and safety standards such as those pub-
lished by the National Fire Protection Association (NFPA), and the American Society
for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local
- 7 -
code authorities.
C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and
other hidden utilities.
D. Ducted fans must always be vented to the outdoors.
E. This unit must be grounded.
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
WARNING - UNDER CERTAIN CIRCUMSTANCES DOMESTIC APPLIANCES MAY BE
DANGEROUS.
A. Do not check filters with hood working.
B. Do not touch the lamps after a prolonged use of the appliance.
C. No food must be cooked flambè underneath the hood.
D. The use of an unprotected flame is dangerous for the filters and could cause fires.
E. Watch constantly while frying food in order to avoid cooking oil flare ups.
F. Before performing any maintenance operation, disconnect the hood from the
electrical service.
The manufacturers will not accept any responsibility for possible damages, because
of failure to observe the above instructions.
- 8 -
THIS HOOD IS DESIGNED TO USE A 6” ROUND DUCT -
IT MAY BE TRANSITIONED TO A 3-1/4” X 10” RECTANGULAR DUCT
NEVER REDUCE DUCT SIZE. UNDERSIZED DUCTING SEVERELY RESTRICTS AIR
FLOW AND HARMS PERFORMANCE.
(Example: the area of a 6” Duct is more than TWICE that of a 4” Duct)
KEEP DUCT RUNS AS SHORT AND STRAIGHT AS POSSIBLE.
AVOID USING FLEXIBLE METAL DUCTING IF RUN IS LONGER THAN 6’.
NEVER USE PLASTIC DUCTING.
USE SMOOTH BORE METAL DUCTING.
MINIMIZE THE NUMBER OF FITTINGS (see chart).
WHEN YOU MUST USE FITTINGS, TRY TO SEPARATE THEM WITH SECTIONS OF
3’ OR MORE OF STRAIGHT DUCT.
ALWAYS FOLLOW THE MANUFACTURER’S GUIDELINES FOR THE COOKING
EQUIPMENT YOU ARE VENTING.
IF MAKE UP AIR CONTROL DAMPERS ARE REQUIRED, POSITION THE SENSOR
IN A STRAIGHT RUN OF DUCT IDEALLY WITH 3’ OF STRAIGHT DUCT BETWEEN
EACH SIDE OF THE SENSOR AND A DUCT FITTING. REMEMBER TO INCLUDE
POWER AND CONTROL WIRING FOR THIS IN YOUR PLANS.
ADHERE TO ALL LOCAL BUILDING CODES AND ORDINANCES.
USE THE WORKSHEET THAT FOLLOWS TO HELP CALCULATE THE
TOTAL EQUIVILENT FEET OF YOUR DUCT RUN.
TOTAL EQUIVILENT FEET SHOULD BE LESS THAN 100’.
a few simple rules to plan your
ductwork
1
1
12
7
14
8
33
2
4
24
24
33
- 9 -
1
1
12
7
14
8
33
2
4
24
24
33
CAUSING AIR TO CHANGE DIRECTION CAUSES TURBULENCE AND RESTRICTS FLOW IN
A SYSTEM.
IF USING FLEXIBLE METAL DUCT - INCREASE ALL MULTIPLIERS BY 50% (12 BECOMES
18 - ETC.)
THIS EASY TO USE WORKSHEET IS FOR 600 CFM OR LESS.
UNDER “QTY USED” ENTER HOW OF EACH SECTION YOU WILL BE USING.
IN THE FIRST TWO ROWS - ENTER HOW MANY FEET OF EACH TYPE OF STRAIGHT DUCT
YOU WILL BE USING (I.E. FOR 20 FT ENTER 20, FOR 30FT ENTER 30).
ENTER THE NUMBER OF EACH TYPE OF TURN YOU ARE USING AND THE TYPE OF END CAP.
MULTIPLY ACROSS EACH ROW THE “MULTIPLIER” x “QTY USED” TO GET THE EQUIVALENT
FEET FOR THOSE COMPONENTS.
ADD UP ALL THE VALUES IN THE “EQUIVALENT FEET” COLUMN.
DUCT PIECE DESCRIPTION MULTIPLIER QTY USED EQUIVALENT
FEET
1’ of 6” Round Duct
1’ of 3 1/4“ x 10” Rect. Duct
6” 90 Degree Elbow
6” 45 Degree Elbow
3 1/4” x 10” 90 Degree
3 1/4” x 10” 45 Degree
3 1/4” x 10” Side 90 Degree
3 1/4” x 10” x 6” Round
3 1/4” x 10” x 6” 90 Degree
6” Round Wall Cap w Damper
3 1/4” x 10” Wall Cap w Damper
6” Round Roof Cap
TOTAL EQUIVALENT FEET SHOULD BE LESS THAN 100
estimating total equivalent feet in
a duct
- 10 -
VENTEDRECIRCULATION
WALL EXHAUST ROOF EXHAUST
GRID EXHAUST
RECIRCULATION
EXHAUST MUST BE RE-
TURNED TO THE SPACE
typical installation examples
11-1/4"
2-3/16"
24-3/4"
A
Max 1117.6 - Min. Extractor 730 - Min Filtering 812.5
Max 44 - Min. Extractor 28-3/4" - Min Filtering 32"
11-1/4"
19-5/16"
- 11 -
11-1/4"
2-3/16"
24-3/4"
A
Max 1117.6 - Min. Extractor 730 - Min Filtering 812.5
Max 44 - Min. Extractor 28-3/4" - Min Filtering 32"
11-1/4"
19-5/16"
 Front of hood  Side of hood
Top of hood
dimensions
MODEL A
XOM30GC 30”
XOM36GC 36”
Duct cover removed
- 12 -
27”to32”
RECOMMENDED
MOUNTING HEIGHT
ABOVE GAS AND
ELECTRIC COOKTOPS
highs and lows
All range hoods have a recommended range of installation height over the cooking
surface.
It is important to install the hood at the proper mounting height. Hoods mounted too
low could result in heat damage and fire hazard; while hoods mounted too high will
be hard to reach and will lose its performance and efficiency.
- 13 -
27”to32”
installation
A
B
MOUNT TO THE WALL:
Drill the holes A respecting the distances
indicated (Fig.1). Fix the appliance to
the wall and align it in horizontal posi-
tion to the wall units. When the appli-
ance has been adjusted, definitely fix
the hood using the screws A (Fig.3). For
the various installations use screws and
screw anchors suited to the type of wall
(e.g. reinforced concrete, plasterboard,
etc.). If the screws and screw anchors are
provided with the product, check that
they are suitable for the type of wall on
which the hood is to be fixed.
INSTALL THE DUCT COVER:
Adjust the width of the support bracket of the upper flue (Fig.2). Then fix it to the ceiling
using the screws A (Fig.3) in such a way that it is in line with your hood and respecting
the distance from the ceiling indicated in Fig.1. Connect the flange C to the air exhaust
hole using a connection pipe (Fig. 3). Insert the upper flue into the lower flue. Fix the
lower flue to the hood using the screws B provided (Fig.3), extract the upper flue up to
the bracket and fix it with the screws B (Fig.2).
IMPORTANT - The range hood must be secured to wall studs or use drywall
anchors capable of supporting 75 lbs.
- 14 -
1. Route the power cord to the junction box.
2. Using listed conduit fittings and connectors, connect the power supply to the box and
each line to the appropriate wire following this color convention:
BLACK = HOT LEG
WHITE = NEUTRAL
GREEN/YELLOW = GROUND
Polarity must be observed.
Unit must be properly grounded.
Use a double throw disconnect switch.
3. Replace the box cover
Replace the Anti-grease flters.
All wiring must be in compliance with national electrical code, ANSI/NFPA 70-1999
and all local codes and regulations.
electrical connection
A Remove the central screw and lift the electrical plant box.
B Remove the 3 fixed screws. Then position the electrical box so it is in line with the holes
of the previously removed screws and tighten.
C Pay attention that the tear tape of the electrical box is inside the slot and then tighten screw.
A B
C D
D
- 15 -
maintenance
Regular cleaning and maintenance is the key to long life and peak performance of any
equipment.
•Theanti-greaselter is used to trap any grease particles suspended in the air, therefore
is subject to saturation (the time it takes for the lter to become saturated depends on the
way in which the appliance is used). The greaseltersshould be cleaned frequently. Use a
warm detergent solution. Grease lters are a dishwasher safe.
- To prevent potential re hazards, the anti-
grease lters should be washed a minimum
of every 2 months (it is possible to use the
dishwasher for this task).
- After a few washes, the colour of the lters
may change. This does not mean they have to
be replaced. If the replacement and washing
instructions are not followed, the anti-grease
lters may present a re hazard.
CLEANING STAINLESS STEEL:
Do not use corrosive detergents, abrasive detergents or oven cleaners.
Do not use any product containing chlorine bleach or any product containing chloride.
Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface.
Cleaning Stainless Steel Clean periodically with warm soapy water and clean cotton cloth or
micro fiber cloth. Always rub in the direction of the stainless steel grain. To remove heavier
grease build up use a liquid degreaser detergent. After cleaning use a non-abrasive stainless
steel polish/cleaners, to polish and buff out the stainless luster and grain. Always rub lightly, with
a clean cotton cloth or a micro fiber cloth and buff in the direction of the stainless steel grain.
Any painted surfaces should be cleaned with warm water and detergent only.
- 16 -
LED LIGHT REPLACEMENT
The LED light modules are held in place by
spring clips which must be squeezed in be-
fore the lamp can be pushed down through
the fascia.
Unplug the plastic molex connector.
Plug in the new fixture and snap back into
place.
XOPSPK6602
maintenance continued
XORFSQR
FOR UNITS USED IN RECIRCULATION MODE ONLY:
This refers to hoods which are not ducted outside but rely instead on carbon filter elements
to help purify the air before it is exhausted back into the room.
The carbon element filters gradually lose efficiency and cannot be cleaned or regenerated.
These must be replaced at least 4 times a year, more frequently if needed based on the
amount of use and style of cooking.
CHANGING THE CARBON FILTERS:
Changing the filters is easy.
To Reduce the Risk of Fire and Shock use only
conversion Kit Model XORFSQR(ACK00083) Filters.
The XORFSQR filters are sold in pairs.
To replace the filters, unlatch and remove the
Anti-Grease filters.
This will expose the blower.
Remove the old filter as shown in the figure and
install the new filter simply align and push into
place to lock.
(UL REFERENCE ACK00083)
- 17 -
BUTTON : LIGHT
BUTTON 0: OFF
BUTTON 1: SPEED I
BUTTON 2: SPEED II
BUTTON 3: SPEED III
BUTTON T:
AUTOMATIC STOP TIMER - 15 minutes (*)
The appliance has the Power Boost speed function: press
BUTTON 3
for two seconds and
it will be activated for 10 minutes after which it will return to the previously set speed. When
the function is active the LED ashes. To interrupt it before the 10 minutes have expired press
BUTTON 3
again.
By pressing
BUTTON T
for two seconds (with the hood switched o) the cleanair” func-
tion is activated. This function switches the appliance on for ten minutes every hour at the
rst speed. As soon as this function is activated the motor starts up at the rst speed for ten
minutes. During this time
BUTTON T
and
BUTTON 1
must ash at the same time.
After ten minutes the motor switches o and the LED of
BUTTON T
remains switched on with
a xed light until the motor starts up again at the rst speed after fty minutes and
BUTTON
T
and
BUTTON 1
start to ash again for ten minutes and so on.
By pressing any key for the exclusion of the hood light the hood will return immediately to its
normal functioning (e.g. if
BUTTON 2
is pressed the cleanair” function is deactivated and
the motor moves to the 2nd speed straight away. By pressing the
BUTTON 0
the function is
deactivated).
(*) The automatic stop timer” delays stopping of the hood, which will continue functioning for
15 minutes at the operating speed set at the time this
function is activated.
•Activecarbon/greaseltersaturation:
- When button ashes at a frequency of 2 seconds, the grease lters must be cleaned.
- When button ashes at a frequency of 0.5 seconds, the carbon lters must be replaced.
After the clean lter has been replaced, the electronic memory must be reset by pressing
button for approximately 5 seconds, until the light on the button stops ashing.
Your XO range hood is controlled by these
electronic push buttons which illuminate when
activated.
easy to operate
- 18 -
Code Compliance Control
New!
Some local codes limit the maximum exhaust airflow of range hoods to 400 CFM
before a Make Up Air System is required.
The XOM30GC and XOM36GC models are supplied with 600 CFM capacity.
The CCC system allows you to limit the hood from 600 CFM to 395 CFM.
Tosetupfor395CFMOperation-followtheprocedurebelow:
1. After the hood has been powered up initially, disconnect the power supply by shutting
off the circuit breaker.
2. VERY IMPORTANT, after turning power back on to the unit, you must press and hold
both the and “0” buttons simultaneously within 5 seconds of re-powering the unit.
NOTE: If you do not press the buttons within the first 5 seconds after turning power back
on to the hood - the CCC function will not engage and you must repeat from Step 1.
3. The control blinks 3 times
4. The hood is now configured at 395 CFM - the POWER BOOST function is also
disabled.
5. Affix the sticker supplied to indicate the unit has been reconfigured to a maximum
air flow of 395 CFM.
6. Once reconfigured for 395 CFM, the unit cannot be reset to 600 CFM.
make up air conversion
- 19 -
Code Compliance Control
RECIRCULATION KITS
FILTERS
REPLACEMENT LIGHTS
REMOTE CONTROLS
DUCT COVERS
REPLACEMENT SWITCHES
BLOWER MOTORS
FAN WHEELS
ALL OF THESE PARTS AND MORE ARE AVAILABLE, SIMPLY
VISITWWW.XOAPPLIANCE.COMandclickonPARTSSTORE
OR CALL US AT 973-403-8900
access parts & accessories
- 20 -
YEAR
WARRANTY
2
PARTS + LABOR
90 DAY LOVE IT or LEAVE IT. For 90 Days all our products are backed by our unique Love it or Leave it Guarantee.
TWO-YEAR PARTS & LABOR LIMITED WARRANTY. XO warrants to the original purchaser of every new XO ventilation
unit, the cabinet and all parts thereof, to be free from defects in material or workmanship under normal and proper use and
maintenance as specified by XO and upon proper installation and start-up in accordance with the instruction packet supplied
with each XO unit. XO’s obligation under this warranty is limited to a period of two (2) years from the date of original purchase.
WARRANTY CLAIMS. All claims for labor or parts must be made directly through XO. All claims should include: model number
and serial number of cabinet, proof of purchase, and date of installation. In case of warranted compressor, the compressor
model tag must be returned to XO along with the above listed information.
WHAT IS NOT COVERED BY THIS WARRANTY. XO’s sole obligation under this warranty is limited to either repair
or replacement of parts, subject to the additional limitations below. This warranty neither assumes nor authorizes any person
to assume obligations other than those expressly covered by this warranty. Open box, factory seconds, scratch and dent, floor
models and commercial applications are excluded from these warranties.
WARRANTY IS NOT TRANSFERABLE. This warranty is not assignable and applies only in favor of the original purchaser/
user at the original installation location. Any such assignment or transfer shall void the warranties herein made and shall void
all warranties, express or implied, including any warranty or merchantability or fitness for a particular purpose.
IMPROPER USAGE. XO assumes no liability for parts or labor coverage for component failure or other damages resulting from
improper usage or installation or failure to clean and/or maintain product as set forth in the warranty packet provided with the unit.
ALTERATION OR NEGLECT. XO is not responsible for the repair or replacement of any parts that XO determines have been
subjected after the date of manufacture to alteration, neglect, abuse, misuse, accident, damage during transit or installation,
fire, flood, or act of God.
IMPROPER ELECTRICAL CONNECTIONS. XO is not responsible for the repair or replacement of failed or damaged
components resulting from electrical power failure, high or low voltage, use of extension cords, or improper grounding of the unit.
YOUR RIGHTS UNDER STATE LAW. This warranty gives you specific legal rights and you may have other rights that
vary from state to state. Some states do not allow the exclusion or limitation of consequential damages or a limitation on how
long an implied warranty lasts, so the above exclusion or limitation may not apply to you.
OUTSIDE U.S. This warranty does not apply to, and XO is not responsible for, any warranty claims made on products sold
or used outside the 48 continental United States.
To obtain service:
Call 973-403-8900 |email ser[email protected] | or submit a request on our website
www.xoappliance.com
we’ve got your back
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

XO M30GC Wall Mount Chimney Range Hood Manuel utilisateur

Catégorie
Hottes
Taper
Manuel utilisateur
Ce manuel convient également à