Heat & Glo fb-grand Install Manual

Catégorie
Cheminées
Taper
Install Manual

Ce manuel convient également à

Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 1
HOT! DO NOT TOUCH.
SEVERE BURNS MAY RESULT.
CLOTHING IGNITION MAY RESULT.
Model(s):
FB-GRAND
FB-IN
Do not store or use gasoline or other À am-
mable vapors and liquids in the vicinity of
this or any other appliance.
What to do if you smell gas
- Do not try to light any appliance
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from a
neighbor’s phone. Follow the gas suppli-
er’s instructions.
- If you cannot reach your gas supplier, call
the ¿ re department.
Installation and service must be performed
by a quali¿ ed installer, service agency, or the
gas supplier.
WARNING: If the information in these
instructions is not followed exactly, a ¿ re
or explosion may result causing property
damage, personal injury, or death.
Owners Manual
Installation and Operation
DO NOT DISCARD THIS MANUAL
CAUTION
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer’s instructions and
the manufactured home construction and safety standard, Title
24 CFR, Part 3280 or Standard for Installation in Mobile Homes,
CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
Leave this manual with
party responsible for use
and operation.
DO NOT
DISCARD
WARNING
• Important operating
and maintenance
instructions included.
Read, understand and follow
these instructions for safe
installation and operation.
In the Commonwealth of Massachusetts:
installation must be performed by a licensed plumber
or gas ¿ tter;
a CO detector shall be installed in the room where the
appliance is installed.
Installation and service of this appliance should be
performed by quali¿ ed personnel. Hearth & Home
Technologies suggests NFI certi¿ ed or factory trained
professionals, or technicians supervised by an NFI
certi¿ ed professional.
This appliance has been supplied with an integral barrier
to prevent direct contact with the ¿ xed glass panel. Do
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
CAREFULLY SUPERVISE children in same room as
appliance.
Alert children and adults to hazards of high temperatures.
Do NOT operate with protective barriers open or
removed.
Keep clothing, furniture, draperies and other
combustibles away.
Glass and other surfaces are hot during
operation and cool down.
• Keep children away.
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07
2
Congratulations
Listing Label Information/Location
Model Name: ___________________________________________ Date purchased/installed: __________________
Serial Number: __________________________________________ Location on appliance: ____________________
Dealership purchased from: _______________________________ Dealer Phone: __________________________
Notes: _______________________________________________________________________________________
_____________________________________________________________________________________________
Congratulations on selecting a Heat & Glo gas appliance
—an elegant and clean alternative to wood burning
appliances. The Heat & Glo gas appliance you have
selected is designed to provide the utmost in safety,
reliability, and ef¿ ciency.
As the owner of a new appliance, you’ll want to read and
carefully follow all of the instructions contained in this
Owners Manual. Pay special attention to all Cautions and
Warnings.
This Owners Manual should be retained for future
reference. We suggest that you keep it with your other
important documents and product manuals.
The information contained in this Owner’s Manual, unless
noted otherwise, applies to all models and gas control
systems.
Your new Heat & Glo gas appliance will give you years of
durable use and trouble-free enjoyment. Welcome to the
Heat & Glo family of appliance products!
Read this manual before installing or operating this appliance.
Please retain this owner’s manual for future reference.
We recommend that you record the following pertinent
information about your appliance.
Gas and Electric
Information
Serial Number
Type of Gas
The model information regarding your speci¿ c appliance can be found on
the rating plate usually located in the control area of the appliance.
Homeowner Reference Information
Heat & Glo, a of Hearth & Home Technologies, Inc.
20802 Kensington Boulevard, Lakeville, MN 55044
brand
Heat & Glo, a of Hearth & Home Technologies, Inc.
20802 Kensington Boulevard, Lakeville, MN 55044
brand
Not
Not
for
for
use
use
with
with
solid
solid
fuel.
fuel.
(
Ne
Ne
doit
doit
pas
pas
entre
entre
utilise
utilise
avec
avec
un
un
combustible
combustible
solide).
solide).
This
This
appliance
appliance
must
must
be
be
installed
installed
in
in
accordance
accordance
with
with
local
local
codes,
codes,
if
if
any;
any;
if
if
not,
not,
follow
follow
ANSI
ANSI
Z223.1
Z223.1
in
in
the
the
USA
USA
or
or
CAN/CGA
CAN/CGA
B149
B149
installation
installation
codes.
codes.
(Installer
(Installer
l’appareil
l’appareil
selon
selon
les
les
codes
codes
ou
ou
reglements
reglements
locaux
locaux
ou,
ou,
en
en
l’absence
l’absence
de
de tels
reglements,
reglements,
selon
selon
les
les
codes
codes
d’installation
d’installation
CAN/CGA-B149.)
CAN/CGA-B149.)
Type
Type
of
of
Gas
Gas
(Sorte
(Sorte
De
De
Gaz)
Gaz):
NA
TURAL
TURAL
GAS
GAS
MADE
MADE
IN
IN
USA
USA
Minimum
Minimum
Permissible
Permissible
Gas
Gas
Supply
Supply
for
for
Purposes
Purposes
of
of
Input
Input
Adjustment.
Adjustment.
Approved
Approved
Minimum
Minimum
(De
(De
Gaz)
Gaz)
Acceptable
Acceptable
0.0
0.0
in
in
w.c.
w.c.
(Po.
(Po.
Col.
Col.
d’eau)
d’eau)
Maximum
Maximum
Pressure
Pressure
(Pression)
(Pression)
0.0
0.0
in
in
w.c.
w.c.
(Po.
(Po.
Col.
Col.
d’eau)
d’eau)
Maximum
Maximum
Manifold
Manifold
Pressure
Pressure
(Pression)
(Pression)
0.0
0.0
in
in
w.c.
w.c.
(Po.
(Po.
Col.
Col.
d’eau)
d’eau)
Minimum
Minimum
Manifold
Manifold
Pressure
Pressure
(Pression)
(Pression)
0.0
0.0
in
in
w.c.
w.c.
(Po.
(Po.
Col.
Col.
d’eau)
d’eau)
Model:
Model:
(Modele):
(Modele):
Serial
Serial
(Serie):
(Serie):
ANSI
ANSI
Z21XX-XXXX
Z21XX-XXXX
·
·
CSA
CSA
2.XX-MXX
2.XX-MXX
·
·
UL307B
UL307B
XXXXXXXX
XXXXXXXX
IN
IN
CANADA
CANADA
ALTITUDE:
ALTITUDE:
0-0000
0-0000
FT.
FT.
0000-0000FT.
0000-0000FT.
MAX.
MAX.
INPUT
INPUT
BTUH:
BTUH:
00,000
00,000
00,000
00,000
MIN.
MIN.
INPUT
INPUT
BTUH:
BTUH:
00,000
00,000
00,000
00,000
ORIFICE
ORIFICE
SIZE:
SIZE:
#XXXXX
#XXXXX
#XXXXX
#XXXXX
XXXXXXXX
XXXXXXXX
Total
Total
Electrical
Electrical
Requirements:
Requirements:
000Vac,
000Vac,
00Hz.,
00Hz.,
less
less
than
than
00
00
Amperes
Amperes
This product may be covered by one or more of the following patents: (Nos produits sont couverts par un ou plusieurs des brevets suivants): (United States)
4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471, 5328356, 5341794, 5347983, 5429495,
5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195,
6053165, 6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2,
6729551, 6736133, 6748940, 6748942, D320652, D445174, D462436; (Canada)1297749, 2195264, 2225408; or other U.S. and foreign patents pending (ou
autres brevets americains et etrangers en attente).
Model Number
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 3
Table of Contents
1 Listing and Code Approvals
A. Appliance Certi¿ cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
B. BTU Speci¿ cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
C. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . . 4
D. Non-Combustible Materials Speci¿ cation. . . . . . . . . . . . . . 4
E. Combustible Materials Speci¿ cation . . . . . . . . . . . . . . . . . 4
2 Getting Started
A. Design and Installation Considerations . . . . . . . . . . . . . . . 5
B. Tools and Supplies Needed . . . . . . . . . . . . . . . . . . . . . . . . 5
C. Inspect Appliance and Components . . . . . . . . . . . . . . . . . . 5
3 Fireplace Size Requirements
A. Minimum Fireplace Opening . . . . . . . . . . . . . . . . . . . . . . . 6
B. Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4 Termination Locations
A. Vent Termination Minimum Clearances . . . . . . . . . . . . . . . 8
5 Vent Information and Diagrams
A. Vent Table Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
B. Horizontal Venting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
C. Measuring Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
6 Installation Preparation
A. Flue Damper. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
B. Chimney . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
C. Gas Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
D. Hearth or Hearth Extension . . . . . . . . . . . . . . . . . . . . . . . 10
E. Fireplace Conversion Notice . . . . . . . . . . . . . . . . . . . . . . 10
F. Remote Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
7 Installing Vent Pipe and Appliance
A. Venting Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
B. Connecting Vent Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
C. Placing, Securing and Leveling the Appliance . . . . . . . . . 12
D. Installing Adaptor and Termination Cap . . . . . . . . . . . . . . 13
8 Gas Information
A. Fuel Conversions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
B. Gas Pressures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
C. Gas Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
9 Electrical Information
A. Wiring the Appliance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
B. Junction Box Installation. . . . . . . . . . . . . . . . . . . . . . . . . . 17
C. Installation for Fan (Optional) . . . . . . . . . . . . . . . . . . . . . . 17
10 Finishing
A. Mantel Projections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
B. Installing Trim Surrounds . . . . . . . . . . . . . . . . . . . . . . . . . 19
11 Appliance Setup
A. Remove Shipping Materials . . . . . . . . . . . . . . . . . . . . . . . 20
B. Clean the Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
C. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
D. Ember Placement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
E. Positioning the Logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
F. Glass Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
G. Air Shutter Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
12 Operating Instructions
A. Before Lighting Appliance. . . . . . . . . . . . . . . . . . . . . . . . . 26
B. Lighting Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
C. Check Pilot Flame Appearance . . . . . . . . . . . . . . . . . . . . 28
D. After Appliance is Lit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
E. Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . 29
13 Troubleshooting
A. Standing Pilot Ignition System . . . . . . . . . . . . . . . . . . . . . 30
14 Maintaining and Servicing Appliance
A. Maintenance Tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
15 Reference Materials
A. Appliance Dimension Diagram . . . . . . . . . . . . . . . . . . . . . 34
B. Vent Kits Components . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
D. Limited Lifetime Warranty . . . . . . . . . . . . . . . . . . . . . . . . . 40
E. Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Î = Contains updated information.
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07
4
Note: To assure top performance, safety and ef¿ ciency,
inserts must be installed with an approved À ue liner as per
CAN/CGA B-149 or National Fuel Gas Code ANSI Z223 and
these instructions.
Note: This installation must conform with local codes. In the
absence of local codes you must comply with the National
Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and
the CAN/CGA B149 Installation Codes in Canada.
1
1 Listing and Code Approvals
C. High Altitude Installations
U.L. Listed gas appliances are tested and approved with-
out requiring changes for elevations from 0 to 2000 feet
in the U.S.A. and Canada.
When installing this appliance at an elevation above
2000 feet, it may be necessary to decrease the input rat-
ing by changing the existing burner ori¿ ce to a smaller
size. Input rate should be reduced by 4% for each 1000
feet above a 2000 foot elevation in the U.S.A., or 10% for
elevations between 2000 and 4500 feet in Canada. If the
heating value of the gas has been reduced, these rules
do not apply. To identify the proper ori¿ ce size, check with
the local gas utility.
If installing this appliance at an elevation above 4500 feet
(in Canada), check with local authorities.
B. BTU Speci¿ cations
MODELS: FB-GRAND, FB-IN
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Vented Gas Appliance Heaters
STANDARD: ANSI Z21.88-2002 • CSA2.33-M2003 • UL307B
Do NOT use this appliance if any part has been under water.
Immediately call a quali¿ ed service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
This product is listed to ANSI standards for “Vented Gas
Appliance Heaters” and applicable sections of “Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles”, and “Gas Fired Appliances for
Use at High Altitudes”.
Models
U.S. (0-2000 ft.) or Canada (2000-4500 ft.)
Maximum
Input
BTU/h
Minimum
Input
BTU/h
Ori¿ ce
Size (DMS)
FB-GRAND (NG) US 40,000 27,000 0.125 mm
CANADA 36,000 24,300 31
FB-IN (NG) US 38,000 27,000 31
CANADA 34,200 24,300 32
FB-GRAND, FB-IN (LP) US 36,000 32,400 49
CANADA 22,000 19,800 50
A. Appliance Certi¿ cation
D. Non-Combustible Materials Speci¿ cation
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750º C, shall be considered
non-combustible materials.
E. Combustible Materials Speci¿ cation
Materials made of or surfaced with wood, compressed
paper, plant ¿ bers, plastics, or other material that can ig-
nite and burn, whether À ame proofed or not, or whether
plastered or unplastered shall be considered combustible
materials.
WARNING
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 5
Heat & Glo gas inserts are designed for recessed installa-
tions into solid fuel masonry or factory built non-combustible
¿ replaces that have been installed in accordance with the
National, Provincial, State and local building codes.
Prior to installing the gas insert:
• Have the chimney and adjacent structure inspected
and cleaned by quali¿ ed professionals. Hearth & Home
Technologies recommends that NFI or CSIA certi¿ ed
professionals, or technicians under the direction of certi-
¿ ed professionals, conduct a minimum of a NFPA 211
Level 2 inspection of the chimney.
Replace component parts of the chimney and ¿ replace
as speci¿ ed by the professionals.
Ensure all joints are properly engaged and the chimney
is properly secured.
When planning an appliance installation, it’s necessary to
determine the following information before installing:
• Minimum ¿ replace size. See Section 3.A.
Gas supply piping.
• Electrical wiring.
• Finishing details.
Existing mantel, mantel legs and wall projection loca-
tions. See Section 3.C.
Whether optional accessories—devices such as a fan,
wall switch, or remote control—are desired.
B. Tools and Supplies Needed
Before beginning the installation be sure that the following
tools and building supplies are available.
Pliers Hi temp caulking material
Hammer Flat blade screwdriver
Voltmeter Framing square
Gloves Variable speed drill
1/4 Hex drive Safety glasses
Manometer Phillips screwdriver
Tape measure Non-corrosive leak check solution
1/2 - 3/4 inch length, #6 or #8 Self-drilling screws
Check building codes prior to installation.
Installation MUST comply with local, regional, state and
national codes and regulations.
Consult insurance carrier, local building, ¿ re of¿ cials or
authorities having jurisdiction about restrictions, installation
inspection, and permits.
A. Design and Installation Considerations
Heat & Glo direct vent gas appliances are designed to
operate with all combustion air siphoned from outside of
the building and all exhaust gases expelled to the outside.
No additional outside air source is required.
2
2 Getting Started
C. Inspect Appliance and Components
Carefully remove the appliance and components from
the packaging.
The vent system components, surrounds and fronts are
shipped in separate packages.
• The ¿ ber logs may be packaged separately and must
be ¿ eld installed.
Report to your dealer any parts damaged in shipment,
particularly the condition of the glass.
Read all of the instructions before starting the insta-
llation. Follow these instructions carefully during the
installation to ensure maximum safety and bene¿ t.
CAUTION
Keep appliance dry.
Mold or rust may cause odors.
Water may damage controls.
Inspect appliance and components for damage.
Damaged parts may impair safe operation.
Do NOT install damaged components.
Do NOT install incomplete components.
Do NOT install substitute components.
Report damaged parts to dealer.
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be voided
by, the following actions:
Installation and use of any damaged appliance or vent
system component.
• Modi¿ cation of the appliance or vent system.
Installation other than as instructed by Hearth & Home
Technologies.
Improper positioning of the gas logs or the glass door.
Installation and/or use of any component part not approved
by Hearth & Home Technologies.
Any such action may cause a ¿ re hazard.
WARNING
WARNING
WARNING
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07
6
3
3 Fireplace Size Requirements
A. Minimum Fireplace Opening
Minimum ¿ replace opening requirements are shown in
Figure 3.1.
• The ¿ rebrick (refractory), glass doors, screen rails,
screen mesh and log grates can be removed from a
factory built ¿ rebox in order to gain minimum gas insert
opening requirements.
Any smoke shelves, shields and bafÀ es may be removed
from a factory built ¿ rebox if attached with mechanical
fasteners.
The metal floor of the factory built firebox may be
removed to facilitate the installation of the insert only
when a 1/4 inch airspace is provided between the insert
and the À oor of outer wrap.
Figure 3.1 Fireplace Opening
NOTE: For actual appliance dimensions refer to Section 16.
B
2 in.
50.8 mm
A
C
TOP VIEW
D
FRONT VIEW
Fire Risk
Provide adequate clearance:
Around air openings
• To combustibles
For service access
Locate appliance away from traf¿ c areas.
WARNING
MINIMUM FIREPLACE SIZE
Location FB-GRAND FB-IN
Inches Millimeters Inches Millimeters
A Front Width 35 889 30-1/4 768.4
B Rear Width 22-5/8 574.7 19 482.6
C Depth 14-1/8 358.8 14-1/8 358.8
D Height 25-3/4 654 22-1/2 571.5
* NOTE: If exhaust collar on insert and ¿ replace damper do not line up, add 4 inches (102 mm) to minimum
¿ replace height for bends in vent pipe.
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 7
B. Clearances
Figure 3.2 Clearances to Mantels or other Combustibles
above Appliance
Fire Risk.
Locate and install appliance to all clearance
speci¿ cations in manual.
Fire Risk.
Odor Risk.
Clearance to combustible material under the
insert is 1/4 inch (0.6 cm).
Use leveling legs to raise insert minimum
1/4 inch above combustible material or outer
wrap of factory built ¿ rebox.
WARNING
WARNING
MEASUREMENTS FROM
TOP EDGE OF UNIT
12 in. MIN.
12 in. MAX.
MANTEL
EXHAUST
VENT PIPE
INLET AIR
VENT PIPE
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07
8
Fire Risk.
Asphyxiation Risk.
Terminations MUST meet minimum clearances.
Exhaust gases are hot.
Nearby vents may draw fumes into house.
A. Vent Termination Minimum Clearances
Figure 4.1 speci¿ es minimum vent heights for various
pitched roofs.
Roof Pitch H (Min.) Ft.
Flat to 6/12...........................................................1.0*
Over 6/12 to 7/12 .................................................1.25*
Over 7/12 to 8/12 .................................................1.5*
Over 8/12 to 9/12 .................................................2.0*
Over 9/12 to 10/12 ...............................................2.5*
Over 10/12 to 11/12 .............................................3.25
Over 11/12 to 12/12 .............................................4.0
Over 12/12 to 14/12 .............................................5.0
Over 14/12 to 16/12 .............................................6.0
Over 16/12 to 18/12 .............................................7.0
Over 18/12 to 20/12 .............................................7.5
Over 20/12 to 21/12 .............................................8.0
Figure 4.1 Minimum height from roof to lowest discharge
opening
4
4 Termination Locations
* 3 foot minimum in snow regions
Figure 4.2 Multiple Vertical Termination
Gas Termination Wood & Fuel Oil Termination
A6 in. 20 in.
18 IN.
A
2 FEET
(MINIMUM) TO
PERPENDICULAR
WALL (GAS ONLY)
GAS OR WOOD
TERMINATION
GAS
TERMINATION
WARNING
HORIZONTAL
OVERHANG
VERTICAL
WALL
GAS DIRECT VENT
TERMINATION CAP
12
X
ROOF PITCH
IS X/ 12
LOWEST
DISCHARGE
OPENING
2 FT.
MIN.
20 INCHES MIN.
H (MIN.) - MINIMUM HEIGHT FROM ROOF
TO LOWEST DISCHARGE OPENING
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 9
CAUTION
ALL vent speci¿ cations MUST be followed.
This product is tested and listed to these speci¿ cations.
Appliance performance will suffer if speci¿ cations are not
followed.
Figure 5.1
C. Measuring Standards
Vertical measurements listed in the vent diagram (Figure
5.1) were made using the following standard:
• Vertical terminations are measured to top of chimney.
Fire Hazard.
Explosion Risk.
Asphyxiation Risk.
Do NOT connect this gas appliance to a
chimney À ue serving a separate solid fuel or
gas burning appliance.
May impair safe operation of this appliance
or other appliances connected to the À ue.
Vent this appliance directly outside.
Use separate vent system for this appliance.
B. Horizontal Venting
Horizontal venting is NOT allowed.
5
5 Vent Information and Diagrams
A. Vent Table Key
The abbreviations listed in this vent table key are used in
the vent diagrams.
Symbol Description
VMIN Minimum Vertical Run Length 14 ft.
VMIN Maximum Vertical Run Length 50 ft.
WARNING
TERMINATION
CAP
ADAPTOR
EXHAUST
VENT PIPE
V= 14 FT. MINIMUM
50 FT. MAXIMUM
3 INCH COLLAR
(Factory installed to
stainless steel section)
WARNING: DO NOT
BLOCK PIPE END WITH
INSULATION OR ANY OTHER
SEALING MATERIAL
STAINLESS STEEL
PIPE - 3 FT. MIN.
REQUIRED (INCLUDED)
INLET AIR
VENT PIPE
COLLAR ATTACHMENT
BRACKET
EXHAUST COLLAR
INLET AIR COLLAR
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07
10
6
6 Installation Preparation
Fire Risk.
A hearth or hearth extension (if present) must
comply with either of the following:
The solid fuel burning ¿ replace manufacturer’s
speci¿ cation.
• Local building codes required by authority
having jurisdiction.
• NFPA 211
Prepare the existing solid fuel masonry or factory built
non-combustible ¿ rebox for installation.
A. Flue Damper
Fully lock the solid fuel ¿ replace’s À ue damper in the open
position, OR completely remove it.
B. Chimney
Ensure chimney is constructed of non-combustible
materials.
• Ensure chimney is clean and in good working order.
Ensure that all chimney cleanouts ¿ t properly to prevent
air leakage into chimney.
C. Gas Line
D. Hearth or Hearth Extension
E. Fireplace Conversion Notice
Permanently attach the label with the following warning
to the inside lower back of the ¿ replace ¿ rebox into which
the insert is being installed. Silicone may be required to
properly secure the label.
Fire Risk.
This ¿ replace has been converted for use with
a gas ¿ replace insert only and cannot be used
for burning wood or solid fuels unless all original
parts have been replaced, and the ¿ replace re-
approved by the authority having jurisdiction.
F. Remote Control
The receiver for the remotes must be installed BETWEEN
the base pan of the insert and the ¿ rebox of the wood-
burning ¿ replace (see photo below).
Note: If the factory built ¿ replace has no gas access hole
provided, an access hole of 1 inch (25 mm) diameter or
less may be drilled through the lower sides or bottom of the
¿ rebox in a proper workmanship - like manner. This access
hole must be plugged with non-combustible insulation after
the gas supply line has been installed.
• Install gas line into ¿ rebox cavity.
Check local codes and gas line sizing requirements
following NFPA51. See Section 8.
Prior to installing the gas insert:
• Have the chimney and adjacent structure inspected
and cleaned by quali¿ ed professionals. Hearth & Home
Technologies recommends that NFI or CSIA certi¿ ed
professionals, or technicians under the direction of certi-
¿ ed professionals, conduct a minimum of a NFPA 211
Level 2 inspection of the chimney.
Replace component parts of the chimney and ¿ replace
as speci¿ ed by the professionals.
Ensure all joints are properly engaged and the chimney
is properly secured.
EXISTING BOTTOM OF
FIREPLACE
REMOTE
RECEIVER
UNIT
EXISTING SIDE
REFRACTORY
WARNING
WARNING
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 11
A. Venting Components
7
7 Installing Vent Pipe and Appliance
The vertical vent termination system installed on this model
includes:
One 3-foot section stainless steel À exible pipe (included
with insert).
One length of 3-inch À exible vent pipe for combustion air
(included with vent kit).
• Flexible vent pipe for exhaust air (included with vent kit).
• One pipe-to-cap adaptor (included with vent kit).
• One vertical termination cap (included with vent kit).
Figure 7.1
B. Connecting Vent Pipe
Reference instructions in the termination kit.
• Install the 3-inch À exible vent pipe(s) down through the
chimney.
Secure the exhaust À exible vent pipe to the 3 foot section
stainless steel flexible vent pipe using the factory-
installed 3-inch collar in the stainless steel section of
pipe (see Figure 7.1).
• Use 3 screws to attach either a 4 foot or 30 foot section
of inlet air vent to the inlet collar on the collar slide plate
(see Figure 7.1). NOTE: The collar slide plate may be
removed from appliance to aid installation.
Seal opening between À ex vent and chimney just above
insert. Unfaced ¿ berglass insulation may be used for this
purpose.
CAUTION
Sharp Edges
Wear protective gloves and safety
glasses during installation.
TERMINATION
CAP
ADAPTOR
EXHAUST
VENT PIPE
V= 14 FT. MINIMUM
50 FT. MAXIMUM
3 INCH COLLAR
(Factory installed to
stainless steel section)
WARNING: DO NOT
BLOCK PIPE END WITH
INSULATION OR ANY OTHER
SEALING MATERIAL
STAINLESS STEEL
PIPE - 3 FT. MIN.
REQUIRED (INCLUDED)
INLET AIR
VENT PIPE
COLLAR ATTACHMENT
BRACKET
EXHAUST COLLAR
INLET AIR COLLAR
Note: To achieve optimum
performance of insert, minimize
or avoid bends in exhaust vent
pipe.
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07
12
Figure 7.2
CUT AND BEND
FLASHING AS NEEDED
TO FIT CHIMNEY
SEALANT
ADHESIVE
Trim chimney top plate to minimize excess overhang or
bend over À ue tile (see Figure 7.2).
• Place 3/8 inch bead of 300º F silicone on À ue tile top.
C. Placing, Securing and Leveling the
Appliance
Install insert (without surround attached) into existing
¿ replace while pulling collar slide plate forward.
• Install gas line into hole provided on insert side.
If applicable install remote control wires into insert side
(see Section 6, F.).
Secure collar slide plate to appliance by placing locking
handle into position with locking tabs (see Figure 7.1)
and secure with #8 screw.
Level the appliance from side to side and front to back. If
necessary, use the leveling legs included with the insert
to set each corner of the base.
Position any excess À exible vent pipe back up into
chimney without sagging. Twist and push flex vent
together to shorten.
Install fiberglass insulation pieces to back face of
surround.
Attach surround. Follow instructions accompanying
surround.
Push insert so that surround becomes tight against face
of ¿ replace.
Fire Risk.
Only an approved Hearth & Home Technologies
surround may be used to cover integral grills on
solid fuel burning ¿ replaces.
No other components such as shrouds, sheet-
metal plates, etc., may be used to seal off vents.
Failure to position the parts in accordance with these diagrams
or failure to use only parts speci¿ cally approved with this
appliance may result in property damage or personal injury.
Explosion Risk.
Combustion Fume Risk.
WARNING
WARNING
WARNING
Connect vent sections per installation instructions.
• The 3 foot section of stainless steel À exible pipe MUST
be attached directly to the exhaust collar on the collar
slide plate.
Connect exhaust vent pipe ONLY to exhaust starting collar
and termination cap center collar.
Connect inlet air vent ONLY to inlet air collar on appliance
and either the termination cap inlet air collar OR terminate
within chimney.
Do NOT allow vent to sag below connection point to
appliance.
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 13
D. Installing Adaptor and Termination Cap
For installation of termination cap see minimum vent
heights for various pitched roofs (see Figure 7.2) .
To install adaptor see Figure 7.3.
Roof Pitch H (Min.) Ft.
Flat to 6/12....................1.0*
Over 6/12 to 7/12 ........1.25*
Over 7/12 to 8/12 ..........1.5*
Over 8/12 to 9/12 ..........2.0*
Over 9/12 to 10/12 ........2.5*
Over 10/12 to 11/12 .....3.25
Figure 7.2 Minimum Height from Roof to Lowest Discharge
Opening
* 3 foot minimum in snow regions
Roof Pitch H (Min.) Ft.
Over 11/12 to 12/12 .......4.0
Over 12/12 to 14/12 .......5.0
Over 14/12 to 16/12 .......6.0
Over 16/12 to 18/12 .......7.0
Over 18/12 to 20/12 .......7.5
Over 20/12 to 21/12 .......8.0
CLASS A PIPE
Figure 7.3
Damper Flashing Kit (Optional)
For use with LINK-DV4-30B Liner Kit.
Note: Damper may have to be removed to use this kit.
• Run À ex liners through 3” holes in damper À ashing.
• Attach damper À ashing to ¿ rebox roof with self tapping
screws included in kit.
Figure 7.4
To help eliminate cold air drafts, it may be necessary to place non-
combustible insulation around the À ues as they go though the damper. Note: The LINK-DV4-30B
system REQUIRES this insulation.
Masonry Factory Built
Wood Burning
EXHAUST
AIR
VENT PIPE
TERMINATION
CAP
LINK-DV30B
Installation LINK-DV4-30B
Installation
INLET AIR
VENT PIPE
WARNING:
DO NOT BLOCK
THIS PIPE END!
INLET AIR
VENT PIPE
EXHAUST
AIR
VENT PIPE
Note: Untwist
the pipe while
extending it, to
achieve full 30’
length.
Remove 18 inch x 18 inch À ashing on cap by removing
3 screws. Connect both the LINK-ZC-ADPB to Class
A Pipe and the termination cap to the LINK-ZC-ADPB
with the self tapping screws provided.
OPTIONAL LINK-ZC-ADPB
FOR USE WITH CLASS A
WOODBURNING PIPE
ÍORÎ
CAUTION
Sharp Edges
Wear protective gloves and safety
glasses during installation.
HORIZONTAL
OVERHANG
VERTICAL
WALL
GAS DIRECT VENT
TERMINATION CAP
12
X
ROOF PITCH
IS X/ 12
LOWEST
DISCHARGE
OPENING
2 FT.
MIN.
20 INCHES MIN.
H (MIN.) - MINIMUM HEIGHT FROM ROOF
TO LOWEST DISCHARGE OPENING
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07
14
Ensure that gas line does not come in contact with outer
wrap of appliance. Follow local codes.
Incoming gas line should be piped into the valve
compartment and connected to the 1/2 inch connection
on the manual shutoff valve.
• Check all ¿ ttings and connections of appliance which
may have loosened during shipping.
8
8 Gas Information
Note: Have the gas supply line installed in accordance
with local building codes, if any. If not, follow ANSI
223.1. Installation should be done by a quali¿ ed installer
approved and/or licensed as required by the locality. (In
the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas ¿ tter).
A. Fuel Conversions
Before making gas connections ensure that appliance be-
ing installed is compatible with the available gas type.
Any natural or propane gas conversions necessary to
meet the appliance and locality needs must be made by
a quali¿ ed technician using Hearth & Home Technologies
speci¿ ed and approved parts.
B. Gas Pressures
Proper input pressures are required for optimum appli-
ance performance. Gas line sizing requirements need to
be made following NFPA51.
Fire Risk.
Explosion Hazard.
High pressure will damage valve.
Disconnect gas supply piping BEFORE
pressure testing gas line at test pressures
above 1/2 psig.
Close the manual shutoff valve BEFORE
pressure testing gas line at test pressures
equal to or less than 1/2 psig.
Verify inlet pressures.
High pressure may cause over¿ re condition.
Low pressure may cause explosion.
Verify minimum pressures when other
household gas appliances are operating.
Install regulator upstream of valve if line
pressure is greater than 1/2 psig.
NOTE: Gas line may be run from either side of the appliance
provided the hole in the outer wrap does NOT exceed 2-1/2
inches in diameter and does not penetrate the ¿ rebox.
NOTE: A listed (and Commonwealth of Massachusetts ap-
proved) 1/2 inch (13 mm) T-handle manual shut-off valve and
À exible gas connector are connected to the 1/2 inch (13 mm)
control valve inlet.
If substituting for these components, please consult
local codes for compliance.
Pressure requirements for appliance are shown in the
table below. Minimum pressures must be met when other
household gas appliances are operating.
Refer to Reference Section 16 for location of gas line
access in appliance.
Gas Leak Risk
Support control when attaching pipe to
prevent bending gas line.
NOTE: The gap between supply piping and gas access
hole may be caulked with high temperature caulk or stuffed
with non-combustible, unfaced insulation to prevent cold air
in¿ ltration.
WARNING
WARNING
Pressure Natural Gas Propane
Minimum inlet pressure 5.0 inches
w.c. 11.0 inches
w.c.
Maximum inlet gas pressure 14.0 inches
w.c. 14.0 inches
w.c.
Manifold pressure 3.5 inches
w.c. 10.0 inches
w.c.
WARNING
C. Gas Connection
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 15
Fire hazard.
Do NOT change the valve settings.
This valve has been preset at the factory.
Changing valve settings may result in ¿ re
hazard or bodily injury.
HIGH ALTITUDE INSTALLATIONS
U.L. Listed gas appliances are tested and approved without
requiring changes for elevations from 0 to 2000 feet in the
U.S.A. and Canada.
When installing this appliance at an elevation above 2000 feet,
it may be necessary to decrease the input rating by changing
the existing burner ori¿ ce to a smaller size. Input rate should
be reduced by 4% for each 1000 feet above a 2000 foot
elevation in the U.S.A., or 10% for elevations between 2000
and 4500 feet in Canada. If the heating value of the gas has
been reduced, these rules do not apply. To identify the proper
ori¿ ce size, check with the local gas utility.
If installing this appliance at an elevation above 4500 feet (in
Canada), check with local authorities.
CHECK FOR GAS LEAKS
Explosion Risk
Fire Risk
Asphyxiation Risk
• Check all ¿ ttings and connections.
Do not use open À ame.
After the gas line installation is complete, all
connections must be tightened and checked
for leaks with a commercially-available,
non-corrosive leak check solution. Be sure
to rinse off all leak check solution following
testing.
Fittings and connections may have loosened
during shipping and handling.
Fire or Explosion Hazard
Gas buildup during line purge may ignite.
Purge should be performed by quali¿ ed technician.
Ensure adequate ventilation.
Ensure there are no ignition sources such as
sparks or open À ames.
A small amount of air will be in the gas supply lines.
When ¿ rst lighting appliance it will take a short time for
air to purge from lines. When purging is complete the
appliance will light and operate normally.
WARNING
WARNING
WARNING
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07
16
A. Wiring the Appliance
9
9 Electrical Information
Note: This appliance must be electrically wired and grounded
in accordance with local codes or, in the absence of local
codes, with National Electric Code ANSI/NFPA 70-latest
edition or the Canadian Electric Code, CSA C221.1.
ON/OFF Switch
An ON/OFF switch is included with appliance and should
attached to surround/facing. (See Installation instructions
for remote control).
If desired an additional wall switch or thermostat may
be added to system as shown in Figure 9.1).
Appliance Requirements
This appliance DOES NOT require 110-120 VAC to
operate.
It is recommended that a 110 VAC junction box be
connected for use with fan or remote control. (See Figure
9.2 for junction box wiring).
Prevent accidental appliance operation when not attended.
Unplug or remove batteries from remote control if absent or
if appliance will not be used for an extended period of time.
Property damage possible from elevated temperatures.
CAUTION
ON
OFF
ON/OFF
SWITCH
REMOTE SWITCH
PIGTAIL
OPTIONAL WALL SWITCH,
THERMOSTAT OR REMOTE
STANDING
PILOT
WHT
RED
VALVE
Note: Electrical wiring must be installed by a licensed
electrician.
Figure 9.1 Standing Pilot Ignition Wiring Diagram
Wire 110V to electrical junction box.
Do NOT wire 110V to valve.
Do NOT wire 110V to wall switch.
Incorrect wiring will damage millivolt valves.
Incorrect wiring will override IPI safety lockout
and may cause explosion.
WARNING
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 17
B. Junction Box Installation
Figure 9.2 Junction box installation
JUNCTION
BOX
SIDEWALL
FEED PLUG
THROUGH HOLE
INSERT STRAIN RELIEF
AROUND CORD IN THIS END
FROM OUTSIDE OF UNIT
SCREW
PROVIDED
Optional Accessories
Connecting the electrical junction box is required if using
a blower or remote.
• Plug the cord into a convenient outlet.
An electrician may install an outlet box inside the
¿ replace. Place the outlet in the lower, back corner of
the ¿ replace.
• Must use cord supplied.
C. Installation for Fan (Optional)
On units already installed removal of decorative front,
surround and gas insert is required.
• Detach À exible liner from back of unit if insert is installed.
Remove the four screws on the cover plate (see Figure 9.3).
Figure 9.3
FAN COVER
PLATE
POWER
CORD
GROUND
WIRE
• Bend up the tabs on the base pan (see Figure 9.4).
• Place the blower in between the bend up tabs.
Install and wire the blower per instruction shipped with
the fan.
The ground wire of the fan can clip on the side of the
base pan.
Reinstall the cover plate back on the unit. Make sure the
fan does not make contact with the back wall to prevent
noise from vibration.
CAUTION
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
Shock hazard.
Replace damaged wire with type 105º C rated
wire.
Wire must have high temperature insulation.
WARNING
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07
18
Figure 9.4 Fan Wiring Diagram
NOTE: IF ANY OF THE ORIGINAL
WIRE AS SUPPLIED WITH THE
APPLIANCE MUST BE REPLACED,
IT MUST BE REPLACED WITH TYPE
1050 C RATED WIRE.
JUNCTION BOX
VARIABLE SPEED CONTROL
TEMPERATURE
SENSOR SWITCH
WHT
GRN
BLK
BLK
110-120 VAC
BLOWER
BLOWER RECEPTACLE
BLK
BLK
BLK
BLK
WHT
GROUND
WHT
BLK
BLK
BLK
FAN
TEMPERATURE
SENSOR SWITCH
SPEED CONTROL
(RHEOSTAT)
JUNCTION
BOX
GROUND WIRE
(ATTACH TO ANY
METAL SURFACE)
BEND
UP TABS
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 19
A. Mantel Projections
Figure 10.1 shows the minimum vertical and corresponding
maximum horizontal dimensions of appliance mantels or
other combustible projections above the top front edge of
the appliance, not the surround.
10
10 Finishing
Figure 10.1 Clearances to Mantels or other Combustibles
above Appliance
MEASUREMENTS FROM
TOP EDGE OF UNIT
12 in. MIN.
12 in. MAX.
MANTEL
EXHAUST
VENT PIPE
INLET AIR
VENT PIPE
B. Installing Trim Surrounds
Combustible materials MUST NEVER overlap onto the
front face.
1. Find the coiled low voltage wires and ON/OFF switch at-
tached to outer right side of the insert (see Figure 10.2).
2. Disconnect the ON/OFF switch from the low voltage wire
leads, and insert the ON/OFF switch through the hole at
the upper right corner of the surround - it will be retained
in the hole.
3. Reconnect the low voltage wires to the ON/OFF
switch.
4. Attach surround assembly by hooking the support
bracket on the locating tabs on top of the gas insert
¿ replace (see Figure 10.2.) Once the surround assem-
bly is on the locating tabs, ensure the bottom hooks
are resting on the locating pins at the base. Reposition
the ¿ replace if necessary. Refer to surround instruc-
tions provided with the decorative surround.
Figure 10.2 Trim Surround Installation
FIREBOX
LOCATING SLOTS
LOCATING TABS
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07
20
Figure 11.1 Placement of Embers
EMBER MATERIAL
(TOP SURFACE,
AND FRONT)
BURNER PAN
AIR
SHUTTER
11
11 Appliance Setup
A. Remove Shipping Materials
Remove shipping materials from inside or underneath the
¿ rebox.
B. Clean the Appliance
Clean/vacuum any sawdust that may have accumulated
inside the ¿ rebox or underneath in the control cavity.
C. Accessories
Install approved accessories per instructions included
with accessories. See Service Parts List for appropriate
accessories. Refer to Section 16.
Shock or ¿ re risk.
Use ONLY optional accessories approved for
this appliance.
Using non-listed accessories voids warranty.
Using non-listed accessories may result in a
safety hazard.
• Only Hearth & Home Technologies approved
accessories may be used safely.
D. Ember Placement
Explosion Risk.
Follow ember placement instructions in manual.
Do NOT place embers directly over burner ports.
Replace ember material annually.
Improperly placed embers interferes with proper burner
operation.
Placing the Ember Material
Ember material is shipped with this gas appliance. To place
the ember material:
• Embers CANNOT be placed directly over ports.
When placing Glowing Embers® onto the burner care
should be taken so that the ports are not covered. Place
the dime-size ember pieces near port holes in burner
top, sides and front (see Figure 11.1). Failure to follow
this procedure will likely cause lighting and sooting
problems.
Place Mystic Ember over burner surface and around
base of burner. Do not cover any burner port holes. Use
this material to give the appliance a realistic ash bed.
Save the remaining ember materials for use during
appliance servicing. The embers provided should be
enough for 3 to 5 applications.
WARNING
WARNING
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37

Heat & Glo fb-grand Install Manual

Catégorie
Cheminées
Taper
Install Manual
Ce manuel convient également à

dans d''autres langues