Titan Impact 440 Manuel utilisateur

Catégorie
Pulvérisateur de peinture
Taper
Manuel utilisateur

Ce manuel convient également à

IMPACT®
440
0523 • Form No. 2417772B
AIRLESS, HIGH-PRESSURE
SPRAYING UNIT
GROUPE DE PROJECTION À
HAUTE PRESSION
AIRLESS EQUIPO DE ALTA
PRESIÓN PARA PULVERIZAR
SERVICE MANUAL
Model 805-000
Model 805-019
Model 805-016
- EN - SERIVCE MANUAL 2
- F - MANUEL D’ENTRETIEN 10
- ES - MANUAL DE MANTENIMIENTO 18
English English
2 © Titan Tool Inc. All rights reserved.
Important Safety Information
Read all safety information before operating the
equipment. Save these instructions.
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury.
To reduce the risks of re or explosion, electrical shock
and the injury to persons, read and understand all
instructions included in this manual. Be familiar with the
controls and proper usage of the equipment.
Grounding Instructions
This product must be grounded. In the event of an electrical short circuit,
grounding reduces the risk of electric shock by providing an escape wire
for the electric current. This product is equipped with a cord having a
grounding wire with an appropriate grounding plug. The plug must
be plugged into an outlet that is properly installed and grounded in
accordance with all local codes and ordinances.
WARNING - Improper installation of the grounding plug
can result in a risk of electric shock.
If repair or replacement of the cord or plug is necessary, do not connect
the green grounding wire to either at blade terminal. The wire with
insulation having a green outer surface with or without yellow stripes is
the grounding wire and must be connected to the grounding pin.
Check with a qualied electrician or serviceman if the grounding
instructions are not completely understood, or if you are in doubt as
to whether the product is properly grounded. Do not modify the plug
provided. If the plug will not t the outlet, have the proper outlet
installed by a qualied electrician.
This product is for use on a nominal 120 volt circuit and has a grounding
plug that looks like the plug illustrated below. Make sure that the product
is connected to an outlet having the same conguration as the plug. No
adapter should be used with this product.
Grounded Outlet
Grounding Pin
Cover for grounded outlet box
IMPORTANT: When the sprayer is used with a generator
or uncontrolled line voltage, the use of Titan’s “Line Surge
Protector” (P/N 800-935) is recommended.
WARNING: EXPLOSION OR FIRE
Solvent and paint fumes can explode or ignite. Property
damage and/or severe injury can occur.
PREVENTION:
Do not spray ammable or combustible materials near an open
ame, pilot lights or sources of ignition such as hot objects,
cigarettes, motors, electrical equipment and electrical appliances.
Avoid creating sparks from connecting and disconnecting power
cords.
Use extreme caution when using materials with a ashpoint
below 100ºF (38ºC). Flashpoint is the temperature that a uid can
produce enough vapors to ignite.
Paint or solvent owing through the equipment is able to result
in static electricity. Static electricity creates a risk of re or
explosion in the presence of paint or solvent fumes. All parts
of the spray system, including the pump, hose assembly, spray
gun and objects in and around the spray area shall be properly
grounded to protect against static discharge and sparks. Use only
conductive or grounded high-pressure airless paint sprayer hoses
specied by the manufacturer.
Verify that all containers and collection systems are grounded to
prevent static discharge.
Connect to a grounded outlet and use grounded extension cords
(electric models only). Do not use a 3 to 2 adapter.
Do not use a paint or solvent containing halogenated
hydrocarbons. Such as chlorine, bleach mildewcide, methylene
chloride and trichloroethane. They are not compatible with
aluminum. Contact the coating supplier about compatibility of
material with aluminum.
Keep spray area well ventilated. Keep a good supply of fresh air
moving through the area to keep the air within the spray area free
from accumulation of ammable vapors. Keep pump assembly in
well ventilated area. Do not spray pump assembly.
Do not smoke in the spray area.
Do not operate light switches, engines, or similar spark producing
products in the spray area.
Keep area clean and free of paint or solvent containers, rags, and
other ammable materials.
Know the contents of the paint and solvents being sprayed.
Read all Material Safety Data Sheets (SDS) and container labels
provided with the paints and solvents. Follow the paint and
solvent manufacture’s safety instructions.
Place pump at least 25 feet (7.62 meters) from the spray object in
a well ventilated area (add more hose if necessary). Flammable
vapors are often heavier than air. Floor area must be extremely
well ventilated. The pump contains arcing parts that emit sparks
and can ignite vapors.
Plastic can cause static sparks. Never hang plastic to enclose spray
area. Do not use plastic drop cloths when spraying ammable
material.
Fire extinguisher equipment shall be present and working.
WARNING: INJECTION INJURY
A high pressure paint stream produced by this equipment
can pierce the skin and underlying tissues, leading to
serious injury and possible amputation. See a physician
immediately.
PREVENTION:
Do not aim the gun at, or spray any person or animal.
Keep hands and other body parts away from the discharge. For
example, do not try to stop leaks with any part of the body.
NEVER put your hand in front of the gun. Gloves will not provide
protection against an injection injury.
ALWAYS keep the tip guard in place while spraying. The tip guard
provides some protection but is mainly a warning device.
Only use a nozzle tip specied by the manufacturer.
Use caution when cleaning and changing nozzle tips. In the
case where the nozzle tip clogs while spraying, ALWAYS lock
gun trigger, shut pump o, and release all pressure before
servicing, cleaning tip or guard, or changing tip. Pressure will
not be released by turning o the motor. The PRIME/SPRAY
valve or pressure bleed valve must be turned to their appropriate
positions to relieve system pressure. Refer to PRESSURE RELIEF
PROCEDURE described in the pump manual.
Do not leave the unit energized or under pressure while
unattended. When the unit is not in use, turn o the unit and
relieve the pressure in accordance with the manufacturer’s
instructions.
High-pressure spray is able to inject toxins into the body and
cause serious bodily injury. In the event that injection occurs,
seek medical attention immediately.
Check hoses and parts for signs of damage, a leak can inject
material into the skin. Inspect hose before each use. Replace any
damaged hoses or parts. Only use TITAN original-high-pressure
hoses in order to ensure functionality, safety and durability.
English English
© Titan Tool Inc. All rights reserved. 3
Important Safety Information
This system is capable of producing 3300 PSI / 228 Bar. Only
use replacement parts or accessories that are specied by the
manufacturer and that are rated a minimum of 3300 PSI. This
includes spray tips, nozzle guards, guns, extensions, ttings, and
hose.
Always engage the trigger lock when not spraying. Verify the
trigger lock is functioning properly.
Verify that all connections are secure before operating the unit.
Know how to stop the unit and bleed pressure quickly. Be
thoroughly familiar with the controls. Pressure will not be
released by turning o the motor. The PRIME/SPRAY valve
or pressure bleed valve must be turned to their appropriate
positions to relieve system pressure. Refer to PRESSURE RELIEF
PROCEDURE described in the pump manual.
Always remove the spray tip before ushing or cleaning the
system.
NOTE TO PHYSICIAN:
Injection into the skin is a traumatic injury which can lead to
possible amputation. It is important to treat the injury as soon as
possible. DO NOT delay treatment to research toxicity. Toxicity
is a concern with some coatings injected directly into the blood
stream. Consultation with a plastic surgeon or reconstructive hand
surgeon may be advisable.
WARNING: HAZARDOUS VAPORS
Paints, solvents, insecticides, and other materials can
be harmful if inhaled or come in contact with the body.
Vapors can cause severe nausea, fainting, or poisoning.
PREVENTION:
Use a respirator or mask if vapors can be inhaled. Read all
instructions supplied with the mask to be sure it will provide the
necessary protection.
Wear protective eyewear.
Wear protective clothing as required by coating manufacturer.
WARNING: GENERAL
Can cause severe injury or property damage.
PREVENTION:
Always wear appropriate gloves, eye protection, clothing and a
respirator or mask when painting.
Do not operate or spray near children. Keep children away from
equipment at all times.
Do not overreach or stand on an unstable support. Keep eective
footing and balance at all times.
Stay alert and watch what you are doing.
Do not operate the unit when fatigued or under the inuence of
drugs or alcohol.
Do not kink or over-bend the hose. Airless hose can develop leaks
from wear, kinking and abuse. A leak can inject material into the
skin.
Do not expose the hose to temperatures or pressures in excess of
those specied by manufacturer.
Do not use the hose as a strength member to pull or lift the
equipment.
Use lowest possible pressure to ush equipment.
Follow all appropriate local, state and national codes governing
ventilation, re prevention and operation.
The United States Government Safety Standards have been
adopted under the Occupational Safety and Health Act (OSHA).
These standards, particularly part 1910 of the General Standards
and part 1926 of the Construction Standards should be consulted.
Before each use, check all hoses for cuts, leaks, abrasion or
bulging of cover. Check for damage or movement of couplings.
Immediately replace hose if any of those conditions exist. Never
repair a paint hose. Replace with a conductive high-pressure
hose.
Do not spray outdoors on windy days.
Always unplug cord from outlet before working on equipment
(electric models only).
Specications
Gallons per minute (GPM) 0.54 (2.2 LPM)
Maximum tip sizes 0.023”
Maximum pressure 3300 PSI (22.8 MPa)
Power 0.87 HP DC motor, 120 V, 60 Hz, 9.0 A
Weight, skid 36 lbs. (16.3 kg)
Weight, high rider 62 lbs (28.1 kg)
Weight, low rider 57 lbs. (25.8 kg)
Spray hose 50’ (15 m) P/N 316-505
Spray lter 60 mesh, P/N 730-067
Maximum hose length 300’ (91.4 m)
Generator requirement 5000 Watt (disable idle-down feature)
Conforms to
UL STD 1450
Certified to CAN/CSA
STD C22.2 No 68
Intertek
Conforms to UL STD 1450
Certied to CAN/CSA STD C22.2 No. 68
Table of Contents
Safety Precautions ........................................................................... 2
Specications ................................................................................... 3
Pressure Relief Procedure ............................................................... 4
Maintenance .................................................................................... 4
General Repair and Service Notes ..........................................................4
Replacing the Motor ....................................................................................4
Replacing the Gears .....................................................................................5
Replacing the Transducer ..........................................................................5
Replacing the PRIME/SPRAY Valve ......................................................... 6
Servicing the Fluid Section ........................................................................6
Replacing the Filters .................................................................................... 8
Troubleshooting .............................................................................. 9
Parts Listings .................................................................................. 26
Main Assembly ............................................................................................26
Siphon Assembly (skid model) ..............................................................28
Skid Assembly ..............................................................................................28
Drive Assembly ............................................................................................29
Fluid Section Assembly ............................................................................30
Low Boy Assembly .....................................................................................32
Cart Assembly ..............................................................................................33
Labels ..............................................................................................................33
Product Registration ..................................................................................34
Electrical Schematic ...................................................................................34
Accessories ....................................................................................................35
Warranty ........................................................................................ 36
English English
4 © Titan Tool Inc. All rights reserved.
Pressure Relief Procedure
Be sure to follow the Pressure Relief Procedure when
shutting down the sprayer for any purpose, including
servicing or adjusting any part of the spray system,
changing or cleaning spray tips, or preparing for
cleanup.
1. Lock the gun by pushing the gun trigger lock to the locked
position.
2. Turn o the sprayer by moving the ON/OFF switch to the OFF
position.
3. Turn the pressure control knob counterclockwise to its OFF
position in the black zone.
4. Unlock the gun by pushing the gun trigger lock to the
unlocked position.
5. Hold the metal part of the gun
rmly to the side of a metal
container to ground the gun and
avoid a build up of static electricity.
6. Trigger the gun to remove any
pressure that may still be in the
hose.
7. Lock the gun by pushing the gun
trigger lock to the locked position.
8. Move the PRIME/SPRAY valve
down to the PRIME position.
Maintenance
Before proceeding, follow the “Pressure Relief
Procedure” outlined previously in this manual.
Additionally, follow all other warnings to reduce the
risk of an injection injury, injury from moving parts
or electric shock. Always unplug the sprayer before
servicing!
General Repair and Service Notes
The following tools are needed when repairing this sprayer:
Phillips Screwdriver 3/8” Hex Wrench
Needle Nose Pliers 5/16” Hex Wrench
Adjustable Wrench 1/4” Hex Wrench
Rubber Mallet 3/16” Hex Wrench
Flat-blade Screwdriver 5/32” Hex Wrench
5/64” Hex Wrench
1. Before repairing any part of the sprayer, read the instructions
carefully, including all warnings.
IMPORTANT: Never pull on a wire to disconnect it. Pulling on a
wire could loosen the connector from the wire.
2. Test your repair before regular operation of the sprayer to be
sure that the problem is corrected. If the sprayer does not
operate properly, review the repair procedure to determine if
everything was done correctly. Refer to the Troubleshooting
Charts to help identify other possible problems.
3. Make certain that the service area is well ventilated in case
solvents are used during cleaning. Always wear protective
eyewear while servicing. Additional protective equipment
may be required depending on the type of cleaning solvent.
Always contact the supplier of solvents for recommendations.
4. If you have any further questions concerning your Titan Airless
Sprayer, call Titan:
Customer Service (U.S.) ..................................... 1-800-526-5362
Replacing the Motor
1. Perform the Pressure Relief Procedure and unplug the sprayer.
2. Loosen and remove the two motor cover screws. Remove the
motor cover.
3. Loosen and remove the three belly pan screws. Remove the
belly pan.
4. On the back of the motor, disconnect the wire coming from
the potentiometer and the wire coming from the transducer.
Also, disconnect the two wires coming from the control panel
board (refer to the electrical schematic in the Parts List section
of this manual).
5. Remove the four control panel mounting screws. Pull back
the control panel for access to the control panel board.
6. At the the control panel board, disconnect the two wires
coming from the motor (refer to the electrical schematic in the
Parts List section of this manual).
7. Loosen and remove the four motor mounting screws.
8. Pull the motor out of the pump housing.
NOTE: If the motor will not dislodge from the pump
housing:
• Remove the front cover plate.
• Using a rubber mallet, carefully tap on the front
of the motor crankshaft that extends through the
slider assembly.
9. With the motor removed, inspect the gears in the pump
housing for damage or excessive wear. Replace the gears, if
necessary.
10. Install the new motor into the pump housing.
11. Secure the motor with the four motor mounting screws.
12. Reconnect the wires (refer to the electrical schematic in the
Parts List section of this manual).
13. Position the control panel on the pump housing and secure in
position using the four control panel mounting screws.
14. Replace the belly pan. Secure with the three belly pan screws.
15. Slide the motor cover over the motor. Secure the motor cover
with the two motor cover screws.
Motor
Motor
mounting
screw
Motor
cover
screw
Belly pan
Belly pan
screw
Front cover screw
Front cover
Motor cover
Control panel
Control panel
mounting screw
English English
© Titan Tool Inc. All rights reserved. 5
Replacing the Gears
1. Perform the Pressure Relief Procedure and unplug the sprayer.
2. Loosen and remove the two motor cover screws. Remove the
motor cover.
3. Loosen and remove the three belly pan screws. Remove the
belly pan.
4. On the back of the motor, disconnect the wire coming from
the potentiometer and the wire coming from the transducer.
Also, disconnect the two wires coming from the control panel
board (refer to the electrical schematic in the Parts List section
of this manual).
5. Remove the four control panel mounting screws. Pull back
the control panel for access to the control panel board.
6. At the the control panel board, disconnect the two wires
coming from the motor (refer to the electrical schematic in the
Parts List section of this manual).
7. Loosen and remove the four motor mounting screws.
8. Pull the motor out of the pump housing.
NOTE: If the motor will not dislodge from the pump
housing:
• Remove the front cover plate.
• Using a rubber mallet, carefully tap on the front
of the motor crankshaft that extends through the
slider assembly.
9. Inspect the armature gear on the end of the motor for
damage or excessive wear. If this gear is completely worn out,
replace the entire motor.
10. Remove and inspect the 2nd stage gear for damage or
excessive wear. Replace if necessary.
11. Remove and inspect the gear and crank assembly for damage
or excessive wear. Replace if necessary.
12. Reassemble the pump by reversing the above steps. During
reassembly, make sure the thrust washer is in place.
NOTE: Rell the gear box in the pump housing with ve
ounces of Lubriplate (P/N 314-171).
Moto
r
Motor
mounting
screw
Motor
cover
screw
Belly pan
Thrust
washer
Gear and
crankshaft
2nd stage
gear
Belly pan
screw
Front cover screw
Front cover
Motor cover
Control panel
Control panel
mounting screw
Replacing the Transducer
1. Loosen and remove the four front cover screws. Remove the
front cover.
2. Stop the sprayer at the bottom of its stroke so that the piston
is in its lowest position.
3. Perform the Pressure Relief Procedure and unplug the sprayer.
Before proceeding, follow the Pressure Relief
Procedure outlined previously in this manual.
Additionally, follow all other warnings to reduce the
risk of an injection injury, injury from moving parts
or electric shock. Always unplug the sprayer before
servicing!
4. Tilt the pump back for easy access to the uid section.
5. Using a 3/8” hex wrench, loosen and remove the two pump
block mounting screws.
6. Pull the pump block down approximately 1/2” from the pump
housing to clear the transducer.
7. Slide the pump block and piston rod forward until the piston
rod is out of the T-slot on the slider assembly.
8. Carefully pull the transducer wire out of the pump housing
until the connection to the transducer jumper is exposed.
Unplug the wire from the transducer jumper (refer to the
electrical schematic in the Parts List section of this manual).
9. Using a wrench, remove the transducer assembly from the
pump block.
10. Thread the new transducer assembly into the pump block.
Tighten securely with a wrench.
11. Plug the new transducer wire into the transducer jumper
(refer to the electrical schematic in the Parts List section of this
manual).
12. Reassemble the pump by reversing steps 1–7.
T-slot
Pump
housing
Pump
block
Pump
block
mounting
screw
Front
cover
Front
cover
screw
Transducer
assembly
English English
6 © Titan Tool Inc. All rights reserved.
Replacing the PRIME/SPRAY Valve
Perform the following procedure using PRIME/SPRAY valve
replacement kit P/N 700-258
1. Push the groove pin out of the valve handle.
2. Remove the valve handle and the cam base.
3. Using a wrench, loosen and remove the valve housing
assembly.
4. Make sure the gasket is in place and thread the new valve
housing assembly into the pump block. Tighten securely with
wrench.
5. Place the cam base over the valve housing assembly.
Lubricate the cam base with grease and line up the cam with
the pump block.
6. Line up the hole on the valve stem with the hole in the valve
handle.
7. Insert the groove pin into the valve handle and through the
valve stem to secure the valve handle in position.
Gasket
Cam base
Valve stem
Pump block
Valve housing
assembly
Valve
handle
Groove pin
Servicing the Fluid Section
Use the following procedures to service the valves and repack the
uid section. Perform the following steps before performing any
maintenance on the uid section.
1. Loosen and remove the four front cover screws. Remove the
front cover.
2. Stop the sprayer at the bottom of its stroke so that the piston
is in its lowest position.
3. Perform the Pressure Relief Procedure and unplug the sprayer.
Before proceeding, follow the Pressure Relief
Procedure outlined previously in this manual.
Additionally, follow all other warnings to reduce the
risk of an injection injury, injury from moving parts
or electric shock. Always unplug the sprayer before
servicing!
4. Unscrew the return hose assembly from the pump block.
Remove the retaining clip from the bottom of the foot valve
housing. Remove the siphon assembly.
5. Tilt the sprayer back for easy access to the uid section.
Pump
block
Bushing
Foot valv
e
ball
Foot valv
e
seat
PTFE
O-ring
Foot valv
e
O-ring
Foot valv
e
seal
Inlet cage
Pusher
stem
housing
Servicing the Valves
The design of the uid section allows
access to the foot valve and seat as well
as the outlet valve and seat without
completely disassembling the uid
section. It is possible that the valves
may not seat properly because of
debris stuck in the foot valve seat or
outlet valve seat. Use the following
instructions to clean the valves and
reverse or replace the seats.
1. Remove the pusher stem clip
and slide the pusher stem
housing from the foot valve
housing.
2. Using a wrench, loosen and
remove the foot valve housing
from the pump block.
3. Clean out any debris in the foot
valve housing and examine
the valve housing and seat. If
the seat is damaged, reverse or
replace the seat.
Outlet valve
retainer
Outlet valve
seat
Outlet valve
ball
Outlet cage
Crush
washer
Piston rod
4. Using a 5/16” hex wrench, loosen and
remove the outlet valve retainer from
the piston rod.
NOTE: Always service the outlet valve
with the piston rod attached to
the pump. This will prevent the
piston rod from rotating during
disassembly of the outlet valve.
5. Clean out any debris and examine the
outlet valve housing and seat. If the
seat is damaged, reverse or replace the
seat.
6. Remove, clean, and inspect the outlet cage, crush washer, and
outlet valve ball. Replace if they are worn or damaged.
NOTE: The outlet cage always must be used with the
crush washer. They are included together in the
repacking kit as assembly P/N 704-642.
7. Reassemble the valves by reversing the steps above.
NOTE: During reassembly of the outlet valve, apply one
drop of Loctite (included in the repacking kit) to
the threads of the outlet valve retainer before
threading it into the piston rod. Then, torque the
retainer to 144 in./lbs. (12 ft./lbs.).
English English
© Titan Tool Inc. All rights reserved. 7
Repacking the Fluid Section
1. Remove the foot valve assembly using the steps in the
“Servicing the Valves” procedure above.
NOTE: The outlet valve does not need to be disassembled
from the piston rod for this procedure.
Slider
assembly
Retainer
nut
Piston
guide
Upper
packing
Pump
block
Lower
packing
Pump bloc
k
mounting
screw
Piston rod
T
-Slot
2. Using 3/8” a hex wrench,
loosen and remove the
two pump block mounting
screws.
3. Pull the pump block down
approximately 1/2” from
the pump housing.
4. Slide the pump block and
piston rod forward until
the piston rod is out of
the T-slot on the slider
assembly.
5. Slide the piston rod out
through the bottom of the
pump block.
6. Loosen and remove the
retainer nut and piston
guide from the pump
block.
7. Remove the upper and
lower packings from the
pump block.
8. Clean the pump block and
install the new upper and
lower packings. Refer to
the illustration below for
proper packing orientation.
Install upper packing
with raised lip and O-ring
facing down.
O-Ring
Raised Lip
Beveled Edge
Install lower packing
with the beveled
edge facing up.
9. Inspect the piston rod for wear and replace if necessary.
10. Reassemble the outlet valve assembly into the piston rod.
Tighten the outlet valve retainer with a wrench until secure.
NOTE: Use the T-slot on the slider assembly to hold the
piston rod in position while securing the outlet
valve retainer.
IMPORTANT: Never use a wrench on the piston itself. This could
cause damage to the piston and cause leakage.
11. Insert the piston guide into the retainer nut. Thread the
retainer nut into the pump block until it is hand tight.
12. Slide the piston guide tool (included in the repacking kit) over
the top of the piston rod and insert the piston rod through
the bottom of the pump block. Using a rubber mallet, tap
the bottom of the piston rod lightly until the piston rod is in
position in the pump block.
NOTE: Coat the piston guide tool and the piston rod with
grease before inserting them into the pump block.
13. Using a wrench, tighten the retainer nut securely.
14. Slide the top of the piston rod into the T-slot on the slider
assembly.
15. Position the pump block underneath the pump housing and
push up until it rests against the pump housing.
16. Thread the pump block mounting screws through the pump
block and into the pump housing. Tighten securely.
17. Reassemble the foot valve assembly into the pump block.
18. For High Rider cart units, thread the siphon tube into the foot
valve and tighten securely. Make sure to wrap the threads on
the siphon tube with PTFE tape before assembly. Replace the
return hose into the hose clip on the siphon tube.
19. For Skid and Low Rider units, insert the elbow on the siphon
assembly into the bottom of the foot valve housing. Push the
retaining clip up into the groove inside the foot valve housing
to secure the siphon assembly in position. Thread the return
hose into the pump block and tighten securely.
20. Place the front cover on the pump housing and secure in
position using the four front cover screws.
21. Turn on the sprayer by following the procedure in the
“Operation” section of this manual and check for leaks.
NOTE: Repacking kit P/N 704-586 is available. For best
results use all parts supplied in this kit.
English English
8 © Titan Tool Inc. All rights reserved.
Replacing the Filters
Pump Filter
1. Loosen and remove the lter housing by hand.
2. Slip the lter o of the lter support spring.
3. Inspect the lter. Based on inspection, clean or replace the
lter.
4. Inspect the seal. Based on inspection, clean or replace the
seal.
5. Slide the new or cleaned lter over the lter support spring
with the adapter in place over the pin on the spring. Push the
lter into the center of the pump block.
6. Slide the lter housing over the lter and thread it into the
pump block until secure.
NOTE: The lter housing should be hand-tightened, but
make sure the lter housing is seated fully into the
pump block.
P
ump
block
Filter
spring
Filter housing
Seal
Filter support
spring
Filter
Adapter
Gun Filter
1. Unclip the top of the trigger guard from the gun body.
2. Using the bottom of the trigger guard as a wrench, loosen and
remove the handle assembly from the gun head.
3. Pull the old lter out of the gun body. Clean or replace.
4. Slide the new lter, tapered end rst, into the gun head.
5. Thread the handle assembly into the gun head. Tighten with
the trigger wrench.
6. Snap the trigger guard back onto the gun body.
Filter
Gun
Body
NOTE: For more detail, part number information, and
complete assembly drawings, please see the RX-80
Airless Gun Owner’s Manual.
English English
© Titan Tool Inc. All rights reserved. 9
Problem
A. The unit will not run.
B. The unit will not prime.
C. The unit will not build or
maintain pressure.
D. Fluid leakage at the upper end
of the uid section.
E. Excessive surge at the spray
gun.
F. Poor spray pattern.
G. The unit lacks power.
Cause
1. The unit is not plugged in.
2. Tripped breaker.
3. The pressure is set too low (pressure control
knob set at minimum setting does not supply
power to unit).
4. Faulty or loose wiring.
5. Excessive motor temperature.
6. ON/OFF switch is defective.
1. The PRIME/SPRAY valve is in the SPRAY
position.
2. Air leak in the siphon tube/suction set.
3. The pump lter and/or inlet screen is clogged.
4. The siphon tube/suction set is clogged.
1. The spray tip is worn.
2. The spray tip is too large.
3. The pressure control knob is not set properly.
4. The pump lter, gun lter, or inlet screen is
clogged.
5. Material ows from the return hose when the
PRIME/SPRAY valve is in the SPRAY position.
6. Air leak in the siphon tube/suction set.
7. There is external uid leak.
8. There is an internal uid section leak
(packings are worn and/or dirty, valve balls
are worn).
9. Worn valve seats
10. Motor powers but fails to rotate
1. The upper packing is worn.
2. The piston rod is worn.
1. Wrong type of airless spray hose.
2. The spray tip worn or too large.
3. Excessive pressure.
1. The spray tip is too large for the material
being used.
2. Incorrect pressure setting.
3. Insucient uid delivery.
4. The material being sprayed is too viscous.
1. The pressure adjustment is too low.
2. Improper voltage supply.
Solution
1. Plug the unit in.
2. Reset the breaker.
3. Turn the pressure control knob clockwise to supply
power to the unit and increase the pressure setting.
4. Inspect or take to a Titan authorized service center.
5. Allow motor to cool.
6. Replace the ON/OFF switch.
1. Rotate the PRIME/SPRAY valve clockwise to the PRIME
position.
2. Check the siphon tube/suction set connection and
tighten or re-tape the connection with PTFE tape.
3. Remove the pump lter element and clean. Remove the
inlet screen and clean.
4. Remove the siphon tube/suction set and clean.
1. Replace the spray tip following the instructions that
came with the spray gun.
2. Replace the spray tip with a tip that has a smaller orice
following the instructions that came with the spray gun.
3. Turn the pressure control knob clockwise to increase the
pressure setting.
4. Remove the pump lter element and clean. Remove the
gun lter and clean. Remove the inlet screen and clean.
5. Clean or replace the PRIME/SPRAY valve.
6. Check the siphon tube/suction set connection and
tighten or re-tape the connection with PTFE tape.
7. Check for external leaks at all connections. Tighten
connections, if necessary.
8. Clean the valves and service the uid section following
the “Servicing the Fluid Section” procedure in the
Maintenance section of this manual.
9. Reverse or replace the valve seats following the
“Servicing the Fluid Section” procedure in the
Maintenance section of this manual.
10. Take unit to a Titan authorized service center.
1. Repack the pump following the “Servicing the Fluid
Section” procedure in the Maintenance section of this
manual.
2. Replace the piston rod following the “Servicing the Fluid
Section” procedure in the Maintenance section of this
manual.
1. Replace hose with a minimum of 50’ of 1/4” grounded
textile braid airless paint spray hose.
2. Replace the spray tip following the instructions that
came with the spray gun.
3. Rotate the pressure control knob counterclockwise to
decrease spray pressure.
1. Replace the spray tip with a new or smaller spray tip
following the instructions that came with the spray gun.
2. Rotate the pressure control knob to adjust the pressure
for a proper spray pattern.
3. Clean all screens and lters.
4. Add solvent to the material according to the
manufacturer’s recommendations.
1. Rotate the pressure control knob clockwise to increase
the pressure setting.
2. Reconnect the input voltage for 120V AC.
Troubleshooting
Français
10 © Titan Tool Inc. Tous droits réservés.
Consignes de sécurite important
Lire toutes ces consignes avant d’utiliser l’appareil.
Garder ces consignes.
Indique une situation à risque, laquelle, si elle n’est pas
évitée, peut entraîner des blessures graves, voire la mort.
Pour réduire les risques d’incendie ou d’explosion,
de choc électrique et de blessure, vous devez lire et
comprendre les directives gurant dans ce manuel.
Familiarisez-vous avec les commandes et l’utilisation
adéquate de l’équipement.
Directives de mise à la terre
Cet appareil doit être mis à la terre. En cas de court-circuit, cette précaution
réduit les risques de choc en procurant un parcours au courant électrique. Le
cordon de l’appareil est doté d’un l de terre relié à la troisième broche de sa
che. Cette dernière doit être branchée dans une prise correctement câblée et
mise à la terre conformément aux codes et règlements locaux.
MISE EN GARDE - Le fait de ne pas brancher correctement la
che trilaire de l’appareil peut entraîner des risques de choc
électrique.
Si on doit réparer ou remplacer le cordon ou la che, ne pas raccorder le
l de terre à la borne des broches plates (lames) de cette dernière. Ce l,
normalement vert (avec ou sans rayures jaunes), doit être relié à la broche de
terre.
Consulter un technicien ou un électricien qualié à défaut de comprendre
l’ensemble des présentes directives ou en cas d’incertitude quant à la mise à
terre de l’appareil. Ne pas modier la che de l’appareil; si elle ne s’adapte pas
dans la prise voulue, la faire remplacer par un électricien qualié.
Conçu pour les circuits de 120 V, cet appareil est doté d’une che ressemblant
à celle illustrée ci-dessous. S’assurer que le produit est connecté à une prise
électrique ayant la même conguration que la che mâle. Ne pas utiliser
d’adaptateur avec ce produit.
Prise trilaire
Broche de mise à la terre
Plaque murale de la prise
IMPORTANT: Quand le pulvérisateur est utilisé avec un générateur de
tension de la ligne ou non, l’utilisation de Titan “Line Surge Protector” (P
/ N 800-935) est recommandé.
MISE EN GARDE : EXPLOSION OU INCENDIE
Les émanations de certains produits peuvent exploser
ou s’enammer, et risquent d’entraîner des dommages
matériels ou de graves blessures.
MESURES PRÉVENTIVES :
Ne pulvérisez pas de matières inammables ou combustibles près
d’une amme nue, de voyants lumineux ou de sources d’ignition
telles que des objets chauds, cigarettes, moteurs, matériel et appareils
électriques. Évitez de produire des étincelles en connectant et en
déconnectant les cordons électriques.
S’entourer de toutes les précautions possibles lorsqu’on utilise
des produits ayant un point d’éclair inférieur à 38°C (100°F). Le
point d’éclair est la température à laquelle le liquide peut créer
susamment de vapeurs et s’enammer.
L’écoulement de peinture ou de solvant dans l’équipement peut
produire de l’électricité statique. L’électricité statique crée un risque
d’incendie ou d’explosion en présence de fumées de peinture ou de
solvant. Toutes les pièces du système du pulvérisateur, y compris la
pompe, l’ensemble du tuyau, le pistolet de pulvérisation et les objets
dans et autour de la zone de pulvérisation doivent être correctement
reliés à la terre pour protéger contre les décharges d’électricité
statique et les étincelles. N’utilisez que des tuyaux conducteurs ou
reliés à la terre pour pulvérisateurs de peinture sous vide à haute
pression, spéciés par le fabricant.
Vériez que tous les conteneurs ou systèmes de stockage sont reliés à
la terre pour éviter les décharges d’électricité statique.
Connectez à une prise électrique avec prise de terre et utilisez des
rallonges électriques reliées à la terre. N’utilisez pas d’adaptateur 3 à 2.
N’utilisez pas de peinture ou de solvant contenant du halon,
par exemple, le chlore, les agents antimoisissure à l’eau de
Javel, le chlorure de méthylène et le trichloroéthane. Ils ne sont
pas compatibles avec l’aluminium. Contactez le fournisseur de
revêtements pour connaître la compatibilité du matériau avec
l’aluminium.
La zone de pulvérisation doit toujours être bien aérée. Une
bonne quantité d’air frais doit constamment traverser la zone de
pulvérisation pour éviter les accumulations de vapeurs inammables.
Le système de pompage doit être placé dans une zone bien aérée. Ne
pulvérisez pas le système de pompage.
Ne fumez pas dans la zone de pulvérisation.
N’actionnez pas d’interrupteurs électriques, de moteurs ou autres
dispositifs produisant des étincelles dans la zone de pulvérisation.
Maintenez la propreté de la zone et veillez à ce qu’elle ne contienne
pas de conteneurs de peinture ou de solvant, de chions et autres
matières inammables.
Sachez ce que contiennent la peinture et les solvants pulvérisés. Lisez
les ches de sécurité du matériel (MSDS) et les étiquettes apposées sur
les conteneurs de peintures et de solvants. Respectez les consignes de
sécurité du fabricant de peinture et de solvant.
Placez la pompe à une distance minimum de 7,62 mètres (25 pieds) de
l’objet à pulvériser, dans une zone bien aérée (ajoutez de la longueur
de tuyau si besoin est). Les vapeurs inammables sont souvent plus
lourdes que l’air. La zone près du sol doit être très bien aérée. La
pompe contient des pièces qui produisent des arcs et émettent des
étincelles pouvant enammer les vapeurs.
Le plastique peut causer des étincelles d’électricité statique.
N’accrochez aucun plastique dans une zone de pulvérisation fermée.
N’utilisez pas de toiles de protection en plastique quand vous
pulvérisez une matière inammable.
Ayez un extincteur en bon état de fonctionnement à portée de main.
MISE EN GARDE : INJECTION CUTANÉE
Le jet de haute pression produit par cet appareil peut
transpercer la peau et les tissus sous-jacents, causant des
blessures graves pouvant entraîner l’amputation.
MESURES PRÉVENTIVES :
Ne dirigez pas le pistolet sur et ne pulvérisez pas les personnes ou les
animaux.
N’approchez pas les mains ni d’autres parties du corps de la sortie du
produit. Par exemple, ne tentez pas d’arrêter une fuite avec une partie
du corps.
NE JAMAIS mettre la main, même gantée, devant le pistolet (les gants
n’orent aucune protection contre les blessures par injection).
TOUJOURS s’assurer que le protège-embout est en place avant
de pulvériser. Il est cependant à noter que, s’il assure une certaine
protection, ce dispositif joue surtout un rôle préventif.
Utilisez exclusivement un embout de buse spécié par le fabricant.
Prenez garde quand vous nettoyez ou que vous changez les embouts
de buse. Si l’embout se bouche pendant que vous pulvérisez,
verrouillez TOUJOURS la détente du pistolet, arrêtez la pompe et
libérez toute la pression avant de réparer ou de nettoyer l’embout
ou le protecteur ou avant de changer d’embout. La pression n’est
pas libérée par l’arrêt du moteur. La poignée du robinet-valve PRIME/
SPRAY doit être placée sur PRIME pour libérer la pression. Consultez
la PROCÉDURE DE DÉCOMPRESSION décrite dans le manuel de la
pompe.
Ne laissez pas l’appareil sous tension ou sous pression quand vous
vous en éloignez. Quand vous n’utilisez pas l’appareil, éteignez-le et
libérez la pression conformément aux instructions du fabricant.
La pulvérisation à haute pression peut injecter des toxines dans le
corps et causer de graves blessures corporelles. Si une telle injection se
produisait, consultez immédiatement un médecin.
Vériez les tuyaux et les pièces pour détecter des signes
d’endommagement : une fuite peut injecter le produit dans la peau.
Inspectez le tuyau avant chaque emploi. Changez tous les tuyaux ou
pièces endommagés. Pour des raisons de fonctionnement, de sécurité
Français
© Titan Tool Inc. Tous droits réservés. 11
Consignes de sécurite important
et de durée de vie, utiliser exclusivement des tuyaux exibles à haute
pression d‘origine de TITAN.
Ce système peut produire une pression de 3 300 PSI / 228 Bar.
N’utilisez que les pièces de rechange ou les accessoires spéciés par le
fabricant et ayant une pression nominale minimum de 3 300 PSI. Ceci
est valable pour les embouts de pulvérisation, les protecteurs de buse,
les pistolets, les rallonges, les raccords et le tuyau.
Verrouillez toujours la détente quand vous ne pulvérisez pas. Vériez
que le verrou de la détente fonctionne correctement.
Vériez que toutes les connexions sont bien serrées avant d’utiliser
l’appareil.
Sachez comment arrêter l’appareil et le dépressuriser rapidement.
Soyez bien familiarisé avec les commandes. La pression n’est pas
libérée lorsque le moteur est arrêté. La poignée du robinet-valve
PRIME/SPRAY doit être placée sur PRIME pour libérer la pression.
Consultez la PROCÉDURE DE DÉCOMPRESSION décrite dans le
manuel de la pompe.
Retirez toujours l’embout de pulvérisation avant de rincer ou de
nettoyer le système.
REMARQUE À L’INTENTION DES MÉDECINS : Les injections cutanées
sont des lésions traumatiques; il importe donc de les traiter sans délai.
On NE DOIT PAS retarder ce traitement sous prétexte de vérier la
toxicité du produit en cause, celle-ci n’étant conséquente que dans le
cas d’injection directe de certains produits dans le système sanguin.
Il pourrait s’avérer nécessaire de consulter un plasticien ou un
spécialiste en chirurgie reconstructive de la main.
MISE EN GARDE : ÉMANATIONS DANGEREUSES
Certains produits (peintures, solvants, insecticides ou
autres) peuvent être nocifs s’ils sont inhalés ou entrent en
contact avec l’organisme. Les émanations de ces produits
peuvent provoquer de graves nausées, évanouissements
ou empoisonnements.
MESURES PRÉVENTIVES :
Se servir d’un masque ou d’un respirateur s’il y a risque d’inhalation
(lire toutes les directives concernant ces dispositifs an de s’assurer
qu’ils orent la protection requise).
Porter des lunettes de protection.
Porter les vêtements de protection prescrits par le fabricant du
produit utilisé.
MISE EN GARDE : GÉNÉRALITÉS
D’autres dangers peuvent entraîner des dommages
matériels ou des blessures graves.
MESURES PRÉVENTIVES :
Portez toujours les gants, la protection oculaire, les vêtements et un
respirateur ou masque appropriés quand vous peignez.
Ne travaillez pas et ne pulvérisez pas près d’enfants. Éloignez toujours
les enfants de l’équipement.
Ne travaillez pas avec les bras au-dessus de la tête ni sur un support
instable. Appuyez-vous bien sur les deux pieds pour toujours
conserver l’équilibre.
Soyez attentif et regardez ce que vous faites.
N’utilisez pas l’appareil quand vous êtes fatigué ou sous l’inuence de
drogues ou d’alcool.
Ne faites pas de nœuds avec le tuyau et ne le tordez pas trop. Le
tuyau à vide peut présenter des fuites suite à l’usure, les nœuds ou
les mauvais traitements. Une fuite risque d’injecter du produit dans la
peau.
N’exposez pas le tuyau à des températures ou des pressions
supérieures à celles spéciées par le fabricant.
N’utilisez pas le tuyau pour tirer ou soulever l’équipement.
Utilisez la plus basse pression possible pour rincer l’équipement.
Respectez tous les codes locaux, étatiques et nationaux qui régulent
la ventilation, la prévention d’incendies et le fonctionnement.
Les normes de sécurité du gouvernement des États-Unis ont été
adoptées dans la loi Occupational safety and Health Act (OSHA). Ces
normes, en particulier la partie 1910 des Normes générales et la partie
1926 des Normes de construction, doivent être consultées.
Avant chaque emploi, vériez tous les tuyaux pour détecter
d’éventuelles coupures, fuites, abrasion ou couvercle bombé. Vériez
l’état ou le mouvement des accouplements. Changez immédiatement
le tuyau si l’une de ces conditions est vériée. Ne réparez jamais un
tuyau de peinture. Remplacez-le par un tuyau conducteur à haute
pression.
Ne pulvérisez pas à l’extérieur par temps venteux.
Débranchez toujours le cordon électrique de la prise avant de
travailler sur l’équipement.
Spécications
Débit (GPM) 0,54 (2,2 LPM)
Embout, dimension
maximale 0.023”
Pression maximale 3 300 PSI (22,8 MPa)
Source de puissance 0,87 HP DC motor, 120 V, 60 Hz, 9,0 A
Poids, support 36 lbs. (16,3 kg)
Poids, chariot 62 lbs. (28,1 kg)
Poids, bas chariot 57 lbs. (25,8 kg)
Flexible de vaporisation
15 m P/N 316-505
Filtre de vaporisation
60 mailles
Cordon d’alimentation
dimension maximale 300’ (91,4 m)
Génératrice 5000 W (désactiver la mort en fonction)
Conforms to
UL STD 1450
Certified to CAN/CSA
STD C22.2 No 68
Intertek
Se conforme à UL STD 1450.
Certié au NON 68 de CSA C 22,2 Nº 68
Table des matières
Consignes de sécurité ................................................................... 10
Specications ................................................................................. 11
Procédure de décompression ....................................................... 12
Maintenance .................................................................................. 12
Généralités concernant la maintenance ............................................12
Remplacement du moteur ......................................................................12
Remplacement des engrenages ...........................................................13
Remplacement du transducteur ...........................................................13
Remplacement de la soupape PRIME/SPRAY ..................................14
Maintenance de la section des liquides .............................................14
Remplacement des ltres ........................................................................16
Dépannage ..................................................................................... 17
Listes de pièces .............................................................................. 26
Vue d’ensemble ...........................................................................................26
Ensemble d’aspiration (support) ...........................................................28
Ensemble de support ................................................................................28
Boîte d’engrenages ....................................................................................29
Section des liquides ...................................................................................30
Ensemble de bas chariot ..........................................................................32
Ensemble de chariot ..................................................................................33
Étiquettes ......................................................................................................33
Enregistrement du produit .....................................................................34
Schéma de raccordement électrique ..................................................34
Accessoires ....................................................................................................35
Garantie .......................................................................................... 36
Français
12 © Titan Tool Inc. Tous droits réservés.
Procédure de décompression
On doit effectuer la procédure de décompression chaque
fois qu’on arrête l’appareil pour en faire la maintenance,
en changer les réglages de vaporisation, en remplacer/
nettoyer les embouts ou en effectuer la préparation en
vue d’un nettoyage.
1. Verrouiller le pistolet en mettant le verrou de détente à la
position appropriée.
2. Arrêter l’appareil en mettant le commutateur à la position
OFF.
3. Tourner le bouton de régulation de la pression vers la gauche,
jusqu’à la position OFF, dans la zone noire.
4. Déverrouiller le pistolet en mettant le verrou de détente à la
position appropriée.
5. Tenir fermement la partie métallique
du pistolet contre le bord d’un
contenant métallique an d’éviter une
accumulation d’électricité statique.
6. Appuyer sur la détente du pistolet
an de purger tout l’air restant dans le
exible.
7. Verrouiller le pistolet en mettant
le verrou de détente à la position
appropriée.
8. Abaisser la soupape PRIME/SPRAY à la
position PRIME.
Maintenance
Avant de procéder, on doit suivre les directives de la
section “Procédure de décompression” du présent
manuel. On doit également respecter tous les autres
avertissements si on veut éviter les blessures par
injection, par contact avec une pièce mobile ou par choc
électrique. Le vaporisateur doit toujours être débranché
avant d’être entretenu ou réparé.
Généralités concernant la maintenance
Pour réparer ou entretenir le vaporisateur, on pourrait avoir à recourir
aux outils suivants :
Tournevis étoile Clé hexagonale de 1,0 cm (3/8 po)
Pince à bec pointu Clé hexagonale de 0,8 cm (5/16 po)
Clé à ouverture variable Clé hexagonale de 0,6 cm (1/4 po)
Maillet en caoutchouc Clé hexagonale de 0,5 cm (3/16 po)
Tournevis plat Clé hexagonale de 0,4 cm (5/32 po)
Clé hexagonale de 0,3 cm (5/64 po)
1. Avant de procéder à la maintenance de n’importe quel
composant du vaporisateur, il faut lire attentivement
les directives ainsi que tous les avertissements qu’elles
contiennent.
IMPORTANT : Ne jamais tirer sur le cordon pour le débrancher,
ce qui pourrait détacher le connecteur des fils.
2. Vérier les résultats de la maintenance eectuée avant
d’utiliser le vaporisateur en conditions normales an de
s’assurer que le problème ait bel et bien été corrigé. Si le
vaporisateur ne fonctionne toujours pas comme il faut,
repasser la procédure pour s’assurer qu’elle ait été bien suivie.
Se reporter ensuite à la section Dépannage pour cerner la
source potentielle du problème.
3. S’assurer que l’endroit choisi soit bien ventilé si des solvants
sont utilisés pour le nettoyage. Toujours porter des lunettes
de protection lorsqu’on procède à la maintenance. D’autres
dispositifs protecteurs pourraient être requis selon le type de
solvant utilisé; on doit toujours communiquer avec le fabricant
de ce dernier pour obtenir ses recommandations à cet eet.
4. Pour toute autre question relative à ce vaporisateur à
dépression, il sut de communiquer avec Titan :
Service à la clientèle (É.-U.) .............................. 1-800-526-5362
Remplacement du moteur
1. Suivre la Procédure de décompression et débrancher
l’appareil.
2. Desserrer et retirer les deux vis du carter de moteur et retirer
ce premier.
3. Desserrer et retirer les trois vis du ventre pan. Retirer le ventre
pan.
4. À l’arrière du moteur, débranchez le l venant du
potentiomètre et le l venant du transducteur. Débranchez
les deux ls venant du panneau de bord. (se reporter au
schéma de raccordement électrique de la section Listes de
pièces du présent manuel).
5. Retirez les quatre vis de montage panneau de contrôle. Tirez
le panneau de contrôle d’accès au panneau de bord.
6. Sur le panneau de bord, débrancher les deux ls venant du
moteur (se reporter au schéma de raccordement électrique de
la section Listes de pièces du présent manuel).
7. Desserrer et retirer les quatre vis de montage du moteur.
8. Retirer le moteur du logement de la pompe.
NOTA : Si le moteur refuse de sortir du logement de la
pompe :
• Retirer le couvercle avant.
• Au moyen d’un maillet en caoutchouc, donner de
petits coups à l’avant du vilebrequin (qui ressort de
la bielle).
9. Une fois le moteur retiré, inspecter les engrenages dans
le logement de la pompe pour y détecter d’éventuels
dommages ou une usure excessive. Les remplacer, le cas
échéant.
10. Installer le nouveau moteur dans le logement de la pompe.
11. Fixer le moteur au moyen des quatre vis de montage.
12. Reconnecter les ls (se reporter au schéma de raccordement
électrique de la section Listes de pièces du présent manuel).
13. Positionnez le panneau de contrôle sur le logement de pompe
et sécuriser en position à l’aide des quatre vis de montage
panneau de contrôle.
14. Remplacer le ventre pan. Glisser le ventre pan en le xant au
moyen des trois is prévues.
15. Glisser le carter sur le moteur en le xant au moyen des deux
vis prévues.
Moteur
Vis de
montage
du moteur
Vis du
carter du
moteur
Ventre pan
Vis de
ventre pan
Vis de couvercle
Couvercle
Carter du moteur
Panneau de
contrôle
Vis de panneau
de contrôle
Français
© Titan Tool Inc. Tous droits réservés. 13 English
Remplacement des engrenages
1. Suivre la Procédure de décompression et débrancher
l’appareil.
2. Desserrer et retirer les deux vis du carter de moteur et retirer
ce premier.
3. Desserrer et retirer les trois vis du ventre pan. Retirer le ventre
pan.
4. À l’arrière du moteur, débranchez le l venant du
potentiomètre et le l venant du transducteur. Débranchez
les deux ls venant du panneau de bord. (se reporter au
schéma de raccordement électrique de la section Listes de
pièces du présent manuel).
5. Retirez les quatre vis de montage panneau de contrôle. Tirez
le panneau de contrôle d’accès au panneau de bord.
6. Sur le panneau de bord, débrancher les deux ls venant du
moteur (se reporter au schéma de raccordement électrique de
la section Listes de pièces du présent manuel).
7. Desserrer et retirer les quatre vis de montage du moteur.
8. Retirer le moteur du logement de la pompe.
NOTA : Si le moteur refuse de sortir du logement de la
pompe :
• Retirer le couvercle avant.
• Au moyen d’un maillet en caoutchouc, donner de
petits coups à l’avant du vilebrequin (qui ressort de
la bielle).
9. Inspecter l’engrenage d’armature à l’extrémité du moteur
pour y détecter d’éventuels dommages ou une usure
excessive. Si cet engrenage est complètement usé, remplacer
tout le moteur.
10. Retirer et inspecter le second engrenage pour y détecter
d’éventuels dommages ou une usure excessive. Le remplacer,
le cas échéant.
11. Retirer et inspecter l’assemblage engrenages/vilebrequin pour
y détecter d’éventuels dommages ou une usure excessive. Le
remplacer, le cas échéant.
11. Remonter la pompe en reprenant les étapes ci-dessus à
l’envers, en s’assurant que les rondelles de butée restent bien
en place.
NOTA : Verser environ 150 ml (5 oz) de Lubriplate (no 314-
171) dans la boîte d’engrenages.
Engrenages/
vilebrequin
Second
engrenage
Mot
eur
Vis de
montage
du moteur
Vis du
carter du
moteur
Ventre pan
Vis de
ventre pan
Vis de couvercle
Couvercle
Carter du moteur
Panneau de
contrôle
Vis de panneau
de contrôle
Rondelle
de butée
Remplacement du transducteur
1. Desserrer et retirer les quatre vis du couvercle avant et retirer
ce dernier.
2. Arrêter le vaporisateur en le bas de course an que le piston
soit à sa position la plus basse.
3. Suivre la Procédure de décompression et débrancher
l’appareil.
Avant de procéder, on doit suivre les directives de
la section Procédure de décompression du présent
manuel. On doit également respecter tous les autres
avertissements si on veut éviter les blessures par
injection, par contact avec une pièce mobile ou par choc
électrique. Le vaporisateur doit toujours être débranché
avant d’être entretenu ou réparé.
4. Incliner la pompe vers l’arrière pour accéder plus facilement à
la section des liquides.
5. Au moyen d’une clé hexagonale de 1,0 cm, desserrer et retirer
les deux vis de montage du bloc pompe.
6. Tirer sur le bloc pompe an de le faire ressortir d’environ
1,5 cm (1/2 po) de son logement, de manière à dégager le
transducteur.
7. Glisser le bloc pompe et la tige du piston vers l’avant jusqu’à
ce que cette dernière sorte de la rainure en T de la bielle.
8. Tirer doucement le l à capteur de la pompe de logement
jusqu’à ce que la connexion avec le transducteur de cavalier
est exposée. Débranchez le l du capteur de cavaliers. (se
reporter au schéma de raccordement électrique de la section
Listes de pièces du présent manuel).
9. Retirez le transducteur de la bloc pompe avec une clé.
10. Installer le nouveau transducteur dans le logement de la
pompe. Serrez avec une clé.
11. Branchez le nouveau transducteur l dans le transducteur de
cavaliers (se reporter au schéma de raccordement électrique
de la section Listes de pièces du présent manuel).
12. Remonter la pompe en reprenant les étapes 1 à 7 à l’envers.
Rainure en T
Logement
de la
pompe
Bloc
pompe
Vis de
montage
du bloc
pompe
C
ouvercle
Vis du
couvercle
Transducteur
Français
14 © Titan Tool Inc. Tous droits réservés.
Remplacement de la soupape PRIME/SPRAY
Pour eectuer cette procédure, on doit se procurer une trousse de
remplacement de soupape PRIME/SPRAY (no 700-258).
1. Pousser la goupille hors de la manette de la soupape
2. Retirer la manette et la base à came.
3. Au moyen d’une clé, desserrer et retirer le logement de la
soupape.
4. S’assurer que le joint d’étanchéité soit à sa place, et visser le
nouveau logement dans le bloc pompe; serrer fermement à
l’aide d’une clé.
5. Mettre la base à came par dessus le logement de la soupape;
la lubrier au moyen de graisse et aligner la came avec le bloc
pompe.
6. Aligner le trou dans la tige de soupape avec celui de la
manette.
7. Insérer la goupille à travers ces deux trous an de xer la
manette en place.
Joint d’étanchéité
Base à came
Tige de la soupape
Bloc pompe
Logement
de la soupape
Manette
de la
soupape
Goupille
Maintenance de la section des liquides
On doit suivre les procédures suivantes pour eectuer la maintenance
des soupapes et remplacer les tampons graisseurs de la section des
liquides. Au préalable, il est cependant important de procéder aux
étapes ci-dessous.
1. Desserrer et retirer les quatre vis du couvercle avant et retirer
ce dernier.
2. Arrêter le vaporisateur en le bas de course an que le piston
soit à sa position la plus basse.
3. Suivre la Procédure de décompression et débrancher
l’appareil.
Avant de procéder, on doit suivre les directives de
la section Procédure de décompression du présent
manuel. On doit également respecter tous les autres
avertissements si on veut éviter les blessures par
injection, par contact avec une pièce mobile ou par choc
électrique. Le vaporisateur doit toujours être débranché
avant d’être entretenu ou réparé.
4. Dévisser le exible de retour du bloc pompe. Retirer l’agrafe
qui xe le bloc d’aspiration à la soupape de retenue; disjoindre
ces éléments.
5. Incliner la pompe vers l’arrière pour accéder plus facilement à
la section des liquides.
Maintenance des soupapes
Bloc
pompe
Manchon
Clapet de
la soupape
de retenue
Siège de
la soupape
de retenue
Joint torique
de PTFE
Logement de
la soupape
de retenue
Joint torique
Joint inférieur
Cage inférieure
Logement de
tige de poussoir
La conception de la section des
liquides du vaporisateur fait en
sorte qu’on peut accéder aux
soupapes de retenue et de sortie,
de même qu’à leur siège respectif,
sans avoir à démonter toute la
section. Il arrive que ces soupapes
soient mal assises à cause de débris
accumulés; en suivant les directives
ci-dessous, on peut les nettoyer et
inverser ou remplacer leur siège.
1. Retirez la agrafe de tige
poussoir faites glisser la tige
poussoir de la logement de
la soupape de retenue
2. Au moyen d’une clé,
desserrer et retirer le
logement de la soupape de
retenue du bloc pompe.
3. Enlever tous les débris dans
le logement et examiner les
composants; si le siège est
endommagé, l’inverser ou le remplacer.
Soupape de
retenue
Siège de
la soupape
de sortie
Clapet de
la soupape
de sortie
Sor
tie de cage
Rondelle
d'écrasement
Tige du piston
4. À l’aide d’une clé hexagonale de 0,8
cm (5/16 po), dévisser et retirer le
logement de la soupape de retenue
de la tige du piston.
NOTA : La tige du piston doit
toujours être raccordée à la
pompe quand on eectue
l’entretien de la soupape de
sortie; ce faisant, on évitera
que la tige pivote lorsqu’on
démonte la soupape.
5. Enlever tous les débris dans le logement et examiner les
composants; si le siège est endommagé, l’inverser ou le
remplacer.
6. Retirer, nettoyer et inspecter la cage et le clapet supérieurs; les
remplacer s’ils sont usés ou endommagés.
NOTA : La sortie de cage doit toujours être utilisé avec
la rondelle d’écrasement. Ils sont inclus dans
l’assemblage P/N 704-642.
Français
© Titan Tool Inc. Tous droits réservés. 15 English
6. Remonter les soupapes en reprenant les étapes ci-dessus à
l’envers.
NOTA : Pendant le remontage de la soupape, appliquer une
goutte de Loctite (inclus dans le kit de remballage)
pour les ls de la sortie soupape de retenue avant
de les assembler dans la tige de piston. Couple de la
retenue à 144 in./lbs. (12 ft./lbs.).
Remplacement des tampons graisseurs
1. Retirer les soupape de retenue en suivant les directives de la
section Maintenance des soupapes ci-dessus.
NOTA : La valve de sortie n’a pas besoin d’être démonté à
partir de la tige de piston pour cette procédure.
Bielle
Écrou de
retenue
Guide-
piston
Tampon
supérieur
Bloc
pompe
Tampons
inf
érieurs
Vis de
montage
du bloc
pompe
Tige du
piston
R
ainure
en T
2. Au moyen d’une clé
hexagonale de 1,0 cm,
desserrer et retirer les deux
vis de montage du bloc
pompe.
3. Tirer sur le bloc pompe
an de le faire ressortir
d’environ 1,5 cm de son
logement.
4. Glisser le bloc pompe
et la tige du piston vers
l’avant jusqu’à ce que cette
dernière sorte de la rainure
en T de la bielle.
5. Glisser la tige du piston hors
de la partie inférieure du
bloc pompe.
6. Desserrer et retirer l’écrou
de retenue et le guide-
piston du bloc pompe.
7. Retirer les tampons
supérieur et inférieurs du
bloc pompe.
8. Nettoyer le bloc pompe
et installer les nouveaux
tampons supérieur et
inférieurs (se reporter à l’illustration ci-dessous pour bien les
orienter).
La bord biseauté
doivent être vers le haut.
La partie surélevée et le
joint torique du tampon
supérieur doivent être
vers le bas.
Joint torique
Partie surélevée
Bord biseauté
9. Inspecter la tige du piston pour y déceler toute trace d’usure
et la remplacer au besoin.
10. Remonter la soupape de sortie dans la tige du piston; serrer
fermement le logement au moyen d’une clé.
NOTA : Se servir de la rainure en T de la bielle pour retenir
la tige du piston quand on serre le logement de la
soupape.
IMPORTANT : On ne doit jamais se servir d’une clé pour serrer le
piston lui-même, ce qui pourrait l’endommager et entraîner des
fuites.
11. Insérer le guide-piston dans l’écrou de retenue et visser
fermement ce dernier à la main dans le bloc pompe.
12. Glisser l’outil guide-piston (inclus dans la trousse de
remplacement des tampons) sur le dessus de la tige du piston,
puis insérer cette dernière dans la partie inférieure du bloc
pompe. À l’aide d’un maillet en caoutchouc, donner de petits
coups au bas de la tige jusqu’à ce qu’elle reprenne sa place
dans le bloc pompe.
NOTA : Enduire de graisse l’outil guide-piston et la tige du
piston avant de les insérer dans le bloc pompe.
13. Au moyen d’une clé, serrer fermement l’écrou de retenue.
14. Glisser le haut de la tige du piston dans la rainure en T de la
bielle.
15. Positionner le bloc pompe sous son logement et l’y insérer
jusqu’au fond.
16. Insérer les vis de montage du bloc pompe à travers ce dernier
et son logement; serrer fermement.
17. Remonter la soupape de retenue dans le bloc pompe.
18. Chariot - Vissez le tube-siphon dans le clapet de pied et vissez
jusqu’à ce qu’il soit solidement xé. Assurez vous de recouvrir
les lets de l’adaptateur du tube intérieur/tube-siphon à l’aide
de ruban de PTFE avant le montage. Remettez le tuyau de
retour dans la bride de serrage du tube-siphon.
19. Support et bas chariot - Insérer le coude du bloc d’aspiration
dans la partie inférieure de la soupape de retenue. Positionner
l’agrafe de retenue dans cette dernière de manière à xer
le bloc d’aspiration. Visser le exible de retour dans le bloc
pompe et serrer fermement.
20. Mettre le couvercle avant sur le logement de la pompe et le
xer au moyen des quatre vis prévues.
21. Mettre le vaporisateur en marche en suivant la procédure
indiquée dans la section Fonctionnement du présent manuel
pour s’assurer de l’absence de fuites.
NOTA : On peut se procurer une trousse de remplacement
des tampons graisseurs (no 704-586), laquelle
contient les éléments qui garantiront les meilleurs
résultats pour cette procédure.
Français
16 © Titan Tool Inc. Tous droits réservés.
Remplacement des ltres
Filtre de pompe
1. Dégager et retirer le logement du ltre.
2. Retirer le lter du ressort du support de ltre.
3. Inspecter le ltre; le nettoyer ou le remplacer au besoin.
4. Inspecter le joint; le nettoyer ou le remplacer au besoin.
5. Faites glisser le nouveau ltre ou nettoyer le ltre au cours du
support avec le soutien de l’adaptateur en place. oussez le
ltre dans le centre de la bloc pompe.
6. Glisser le logement sur le ltre et le visser solidement sur le
bloc pompe.
NOTA : Le ltre de logement devraient être serrés la main,
mais assurez-vous que le logement du ltre est assise
pleinement dans le bloc pompe.
Bloc pompe
Ressort
du ltre
Logement
du ltre
Joint torique
Ressort du
support de ltre
Filtre
Adaptateur
Filtre de pistolet
1. Détachez le dessus du pontet de la corps du pistolet.
2. En se servant de la partie inférieure du pontet comme clé,
desserrez et enlevez l’ensemble de la poignée de la tête du
pistolet.
3. Extrayez le ltre usagé de la corps du pistolet. Nettoyez ou
remplacez.
4. Faites glisser le nouveau ltre, la partie letée en premier,
dans la corps du pistolet.
5. Placez le joint de la poignée dans la corps du pistolet avec la
partie plate du joint vers la tête du pistolet. Serrez à l’aide de
la clé de la détente.
6. Enclenchez à nouveau le pontet sur la corps du pistolet.
Poignée
Filtre
Co
rps du
pistolet
NOTA : Pour obtenir plus de détails, se renseigner sur les
numéros de pièce ou voir des dessins d’assemblage
à plus grande échelle, se reporter au manuel de
l’utilisateur du pistolet à dépression professionnel
RX-80.
Français
© Titan Tool Inc. Tous droits réservés. 17
Problème
A. L’appareil ne fonctionne pas.
B. L’appareil ne s’amorce pas.
C. La pression ne se fait pas dans
l’appareil ou la pression n’est
pas uniforme.
D. Fuite de liquide dans la partie
supérieure de la section des
liquides.
E. Trop grand aux au pistolet
vaporisateur.
F. Forme de vaporisation
incorrecte.
G. L’outil n’est pas alimenté
électriquement.
Cause
1. L’appareil n’est pas branché.
2. Disjoncteur déclenché.
3. Le réglage de pression est trop bas (le bouton
de commande de la pression au réglage
minimum n’envoie pas de puissance au
vaporisateur).
4. Câblage défectueux ou débranché.
5. Température excessive du moteur.
6. Commutateur MARCHE/ARRÊT défectueux.
1. La soupape de PRIME/SPRAY est en position
SPRAY.
2. Fuite d’air dans le exible du siphon/
d’aspiration.
3. Le ltre de la pompe et/ou le ltre d’entrée
sont bouchés.
4. Le exible de siphon/d’aspiration est bouché.
1. L’embout d’aspiration est usé.
2. L’embout d’aspiration est trop grand.
3. Le bouton de commande de la pression n’est
pas correctement xé.
4. Le ltre de la pompe, le ltre du pistolet ou le
ltre d’entrée sont bouchés.
5. Du produit s’échappe du exible de retour
lorsque la soupape de PRIME/SPRAY est en
position SPRAY.
6. Fuite d’air dans le exible du siphon/le
exible d’aspiration.
7. Il y a une fuite de liquide externe.
8. Il y a une fuite interne dans la section des
liquides (les tampons graisseurs sont usés et/
ou sales, les clapets sont usés).
9. Sièges de soupape usés.
10. Le moteur démarre mais ne tourne pas.
1. Les tampons graisseurs supérieurs sont usés.
2. La tige du piston est usée.
1. Mauvais type de exible de vaporisation sans
air.
2. L’embout d’aspiration est usé ou trop grand.
3. Pression excessive.
1. L’embout d’aspiration est trop grand pour le
produit utilisé.
2. Mauvais réglage de pression.
3. Sortie de liquide insusante.
4. Le produit vaporisé est trop visqueux.
1. Le réglage de la pression est trop faible.
2. Mauvaise tension d’alimentation.
Solution
1. Brancher l’appareil.
2. Réenclencher le disjoncteur.
3. Faire tourner le bouton de commande de la pression
pour alimenter l’appareil et accroître la pression.
4. Vérier ou le faire réparer dans un centre d’entretien
agrée par Titan.
5. Laisser le moteur refroidir.
6. Replacer le commutateur MARCHE/ARRÊT.
1. Faire tourner la soupape PRIME/SPRAY dans le sens des
aiguilles d’une montre en position PRIME.
2. Vérier le branchement du exible du siphon/
d’aspiration et serrer ou recoller le raccord avec du
ruban en PTFE.
3. Démonter le ltre de la pompe et le nettoyer. Démonter
le ltre d’entrée et le nettoyer.
4. Démonter le exible du siphon/d’aspiration et le nettoyer.
1. Remplacer l’embout d’aspiration selon les consignes qui
accompagnent le pistolet de vaporisation.
2. Remplacer l’embout d’aspiration par un embout à moins
large selon les consignes qui accompagnent le pistolet
de vaporisation.
3. Tourner le bouton dans le sens des aiguilles d’une
montre pour augmenter la pression.
4. Démonter le ltre de la pompe et le nettoyer. Retirer
le ltre du pistolet et le nettoyer. Démonter le ltre
d’entrée et le nettoyer.
5. Nettoyer ou remplacer la soupape de PRIME/SPRAY.
6. Vérier le branchement du exible du siphon/
d’aspiration et serrer ou recoller le raccord avec du
ruban en PTFE.
7. Vérier qu’il n’y a pas de fuites externes dans tous les
raccords. Resserrer les raccords au besoin.
8. Nettoyer les soupapes et la section des liquides selon
la procédure “Maintenance de la Section des Liquides”
décrite au chapitre Maintenance de ce manuel.
9. Inverser ou remplacer les sièges de soupape selon la
procédure “Maintenance de la Section des Liquides”
décrite au chapitre Maintenance de ce manuel.
10. Faire réparer dans un centre d’entretien agrée par Titan.
1. Regarnir selon la procédure “Maintenance de la Section
des Liquides” décrite au chapitre Maintenance de ce
manuel.
2. Remplacer la tige du piston selon la procédure
“Maintenance de la Section des Liquides” décrite au
chapitre Maintenance de ce manuel.
1. Remplacer le exible par un exible de vaporisation de
peinture sans air en tresse de textile de 1/4” et de 15m
de longueur.
2. Remplacer l’embout d’aspiration selon les consignes qui
accompagnent le pistolet de vaporisation.
3. Faire tourner le bouton de commande de la pression
dans le sens inverse des aiguilles d’une montre pour
réduire la pression d’évaporation.
1. Remplacer l’embout d’aspiration par un embout neuf
ou plus petit selon les consignes qui accompagnent le
pistolet de vaporisation.
2. Faire tourner le bouton de commande de la pression
pour régler la pression sur une forme de vaporisation
plus adapter.
3. Nettoyer toutes les crépines et tous les ltres.
4. Ajouter du solvant au produit selon les
recommandations du fabricant.
1. Faire tourner le bouton de commande de la pression
dans le sens des aiguilles d’une montre pour augmenter
la pression.
2. Rebrancher sur 120 V AC.
Dépannage
Español
18 © Titan Tool Inc. Todos los derechos reservados.
Información de seguridad importante
Lea toda la información de seguridad antes de
operar el equipo. Guarde estas insturcciones.
Indica una situación peligrosa que, de no evitarse,
puede causar la muerte o lesiones graves.
Para reducir los riesgos de incendios, explosiones,
descargas eléctricas o lesiones a las personas, lea y
entienda todas las instrucciones incluidas en este
manual. Familiarícese con los controles y el uso
adecuado del equipo.
Instrucciones para la conexión a tierra
Este producto debe conectarse a tierra. En caso de un cortocircuito eléctrico,
la conexión a tierra reduce el riesgo de choque eléctrico al aportar un alambre
de escape para la corriente eléctrica. Este producto está equipado con un
cable que tiene alambre a tierra con un enchufe a tierra adecuado. Debe
usarse el enchufe para conectar a un receptáculo que esté debidamente
instalado y conectado a tierra en conformidad con los códigos y las
ordenanzas locales.
ADVERTENCIA - La instalación incorrecta del enchufe a tierra
puede ocasionar un riesgo de choque eléctrico.
Si es necesario reparar o cambiar el cable o el enchufe, no conecte el cable
verde a tierra a ninguno de las terminales de espiga plana. El cable con
aislamiento de color verde por fuera con o sin rayas amarillas es el alambre a
tierra y debe conectarse a la espiga a tierra.
Consulte a un electricista o técnico de servicio capacitado si las instrucciones
para la conexión a tierra no se entienden claramente o si tiene dudas en
cuanto a que el producto esté debidamente conectado a tierra. No modique
el enchufe que se incluye. Si el enchufe no encaja en el receptáculo, pida a un
electricistas capacitado que instale un receptáculo adecuado.
Este producto es para utilizarse en un circuito de 120 voltios nominales y
tiene un enchufe a tierra que tiene un aspecto similar al ilustrado más abajo.
Asegúrese que el producto esté conectado a un tomacorriente que tenga la
misma conguración que el enchufe. No deben utilizarse adaptadores para
este producto.
Receptáculo conectado a tierra
Pata a tierra
Tapa de la caja de receptáculo conectada a tierra
IMPORTANTE: Cuando se usa el rociador con un generador o línea o sin
control, uncontrolled line voltage, se recomienda que Titan’s “Line Surge
Protector” (P/N 800-935) se utiliza.
ADVERTENCIA: EXPLOSIÓN O INCENDIO
Los vapores de solventes y pinturas pueden explotar o
inamarse. Pueden producirse daños materiales, lesiones
graves o ambos.
PREVENCIÓN:
No pulverice materiales inamables ni combustibles cerca de llamas
desnudas, pilotos o fuentes de ignición como objetos calientes,
cigarrillos, motores, equipos eléctricos o electrodomésticos. Evite
producir chispas al conectar y desconectar los cables de alimentación.
Tenga muchísmo cuidado al usar materiales cuyo punto de ignición
sea inferior a 38 ºC (100 °F). El punto de inamación es la temperatura
a la que un uido puede producir vapor suciente como para
incendiarse.
La pintura o disolvente que pase por el equipo puede producir
electricidad estática. La electricidad estática supone un riesgo de
incendio o explosión en presencia de emanaciones de pintura o
disolvente. Todas las piezas del sistema pulverizador, incluyendo
la bomba, el conjunto de mangueras, la pistola pulverizadora y los
objetos dentro y alrededor de la zona de pulverización se conectarán
a tierra para protegerlos frente a descargas estáticas y chispas. Utilice
solamente mangueras para pulverizadores de pintura airless (sin aire)
de alta presión conductoras o con toma a tierra especicadas por el
fabricante.
Compruebe que todos los recipientes y sistemas de recogida están
conectados a tierra para evitar descargas eléctricas.
Conecte a una salida con toma a tierra y utilice cables alargadores
puestos a tierra. No utilice un adaptador de 3 a 2.
No utilice pintura o disolvente que contenga hidrocarburos
halogenados, como cloro, fungicida blanqueador, cloruro de
metileno y tricloroetano. No son compatibles con el aluminio.
Póngase en contacto con el proveedor del material para conocer su
compatibilidad con el aluminio.
Mantenga la zona de pulverización bien ventilada. Asegúrese de que
circula aire fresco por la zona para evitar que se acumulen vapores
inamables en el aire de la zona de pulverización. Ponga el conjunto
de la bomba en una zona bien ventilada. No pulverice el conjunto de
la bomba.
No fume en la zona de pulverización.
No encienda interruptores de luces, motores ni productos similares
que puedan producir chispas en la zona de pulverización.
Mantenga la zona limpia y despejada de botes de pintura y
disolventes, trapos y otros materiales inamables.
Infórmese del contenido de la pintura y de los disolventes que
pulverice. Lea las hojas de datos sobre seguridad de los materiales
(MSDS) y las etiquetas en los botes de pintura y disolvente. Siga
las instrucciones de seguridad del fabricante de la pintura y del
disolvente.
Coloque la bomba al menos a 7,62 metros (25 pies) del objeto que se
va a pulverizar en una zona bien ventilada (añada más manguera si
fuera necesario). Los vapores inamables suelen ser más pesados que
el aire. La zona del suelo debe estar muy bien ventilada. La bomba
contiene piezas que forman arcos que producen chispas y pueden
inamar los vapores.
El plástico puede producir chispas estáticas. Nunca utilice plástico
para cercar la zona de pulverización. No utilice cortinas de plástico
mientras pulveriza material inamable.
Deberá contar con equipos extintores de incendios que funcionen
correctamente.
ADVERTENCIA: LESIÓN POR INYECCIÓN
El ujo de pintura a alta presión que produce este
equipo puede perforar la piel y los tejidos subyacentes,
ocasionando lesiones graves y posible amputación.
CONSULTE A UN MÉDICO INMEDIATAMENTE.
PREVENCIÓN:
No apunte con la pistola ni pulverice sobre ninguna persona ni animal.
Mantenga las manos y el resto del cuerpo lejos de la descarga. Por
ejemplo, no trate de detener fugas con ninguna parte de su cuerpo.
NUNCA ponga la mano frente a la pistola. Los guantes no protegen
contra una lesión por inyección.
SIEMPRE mantenga la protección de la boquilla en su sitio al rociar.
La protección de la boquilla sirve principalmente de dispositivo de
advertencia.
Utilice solamente la boquilla especicada por el fabricante.
Tenga cuidado al limpiar y cambiar las boquillas. Si la boquilla se
atasca durante la pulverización, ponga SIEMPRE el seguro del gatillo
de la pistola, apague la bomba y libere toda la presión antes de
reparar, limpiar el protector o la boquilla o cambiar la boquilla. La
presión no se libera apagando el motor. Para liberar la presión hay
que poner la manija de la válvula PRIME/SPRAY en PRIME. Consulte el
Procedimiento de Alivio de Presión que se describe en el manual de la
bomba.
No deje el aparato con corriente ni con presión cuando nadie esté
pendiente de ella. Cuando no utilice el aparato, apáguelo y libere la
presión siguiendo las instrucciones del fabricante.
La pulverización a alta presión puede inyectar toxinas en el cuerpo y
producir daños graves en el mismo. En caso de que esto ocurra, visite
a un médico inmediatamente.
Compruebe las mangueras y las piezas en busca de daños; una fuga
puede inyectar material en la piel. Inspeccione la manguera antes de
cada uso. Sustituya las mangueras o las piezas dañadas. Por razones
Español
© Titan Tool Inc. Todos los derechos reservados. 19
Información de seguridad importante
de funcionamiento, seguridad y duración, emplear únicamente
mangueras de alta presión originales de TITAN.
Este sistema es capaz de producir 3300 PSI / 228 Bar. Utilice solamente
piezas de repuesto o accesorios especicados por el fabricante y
con una capacidad nominal de 3300 PSI como mínimo. Entre ellos
se incluyen boquillas pulverizadoras, protectores para las boquillas,
pistolas, alargadores, racores y mangueras.
Ponga siempre el seguro del gatillo cuando no esté pulverizando.
Verique que el seguro del gatillo funciona correctamente.
Antes de utilizar el aparato, verique que todas las conexiones son
seguras.
Aprenda a detener el aparato y a liberar la presión rápidamente.
Familiarícese a conciencia con los controles. La presión no se libera
apagando el motor. Para liberar la presión hay que poner la manija
de la válvula PRIME/SPRAY en PRIME. Consulte el Procedimiento de
Alivio de Presión que se describe en el manual de la bomba.
Quite siempre la boquilla pulverizadora antes de enjuagar o limpiar el
sistema.
NOTA PARA EL MÉDICO: La inyección a través de la piel es una lesión
traumática. Es importante tratar la lesión tan pronto sea posible. NO
retrase el tratamiento para investigar la toxicidad. La toxicidad es un
factor a considerar con ciertos revestimientos inyectados directamente
en la corriente sanguínea. Puede ser aconsejable consultar con un
cirujano plástico o un cirujano especialista en reconstrucción de las
manos.
ADVERTENCIA: VAPORES PELIGROSOS
Las pinturas, solventes, insecticidas y demás materiales
pueden ser nocivos si se inhalan o toman contacto con
el cuerpo. Los vapores pueden causar náuseas graves,
desmayos o envenamiento.
PREVENCIÓN:
Use un respirador o mascarilla si pueden inhalarse los vapores. Lea
todas las instrucciones suministradas con la mascarilla para revisar
que brinde la protección necesaria.
Use lentes protectores.
Use ropa protectora según lo indique el fabricante del revestimiento.
ADVERTENCIA: GENERAL
Puede causar daños materiales o lesiones graves.
PREVENCIÓN:
Cuando pinte, lleve siempre guantes, protección para los ojos, ropa y
un respirador o máscara adecuados.
Nunca utilice el aparato ni pulverice cerca de niños. Mantenga el
equipo alejado de los niños en todo momento.
No se estire demasiado ni se apoye sobre un soporte inestable.
Mantenga los pies bien apoyados y el equilibrio en todo momento.
No se distraiga y tenga cuidado con lo que hace.
No utilice el aparato si está fatigado o se encuentra bajo la inuencia
del alcohol o de las drogas.
No retuerza ni doble la manguera en exceso. En la manguera airless
pueden aparecer fugas a causa del desgaste, de retorcimientos o de
un mal uso. Una fuga puede inyectar material en la piel.
No exponga la manguera a temperaturas o presiones que superen las
especicadas por el fabricante.
No utilice la manguera como elemento de fuerza para tirar del equipo
o levantarlo.
Utilice la presión más baja posible para enjuagar el equipo.
Cumpla todos los reglamentos locales, estatales y nacionales
pertinentes relativos a ventilación, prevención de incendios y
funcionamiento.
Las normas sobre seguridad del gobierno de los Estados Unidos se
han adoptado al amparo de la Ley de salud y seguridad ocupacional
(OSHA). Deben consultarse tres normas, particularmente la sección
1910 de las Normas generales y la sección 1926 de las Normas sobre
construcción.
Cada vez que vaya a utilizar el equipo, compruebe antes todas las
mangueras en busca de cortes, fugas, abrasión o bultos en la cubierta.
Compruebe el movimiento de los acoplamientos y si están dañados.
Sustituya inmediatamente una manguera si descubre alguna de estas
anomalías. No repare nunca una manguera de pintura. Sustitúyala por
una manguera conductora a alta presión.
No pulverice al aire libre si hace viento.
Desenchufe siempre el cable antes de trabajar en el equipo.
Especicaciones
Capacidad (GPM) 0.54 (2.2 LPM)
Tamaño max. de soportes 0.023”
Max presión de pulverización 3300 PSI (22.8 MPa)
Suminstro eléctrico 0.87 HP DC motor, 120 V, 60 Hz,
9.0 A
Peso, soporte 36 lbs. (16.3 kg)
Peso, carro 62 lbs (28.1 kg)
Peso, bajo carro 57 lbs. (25.8 kg)
Manguera rociadora 15 m, P/N 316-505
Filtro rociadora 60 malla, P/N 730-067
Cable de alimentación,
dimensión máxima 91.4 m
Requistos eléctricos de
generado 5000 W (desactivar característica
de hacia abajo)
Conforms to
UL STD 1450
Certified to CAN/CSA
STD C22.2 No 68
Intertek
Se conforma con UL STD 1450.
Certicadas para CAN/CSAC 22.2
NO 68.
Contenido
Precauciones de seguridad ........................................................... 18
Especicaciones ............................................................................. 19
Procedimiento para aliviar la presión.......................................... 20
Mantenimiento .............................................................................. 20
Notas generales de reparación y servicio .................................... 20
Reemplazo del motor ................................................................................20
Reemplazo de los engranajes ................................................................21
Reemplazo del transductor .....................................................................21
Reemplazo de la válvula de PRIME/SPRAY .......................................22
Servicio a la sección de líquidos ............................................................22
Reemplazo de los ltros ...........................................................................24
Solución de problemas ................................................................. 25
Listados de piezas ......................................................................... 26
Ensamblaje principal .................................................................................26
Ensamblaje del juego de succión (soporte) ......................................28
Ensamblaje de la soporte ........................................................................28
Ensamblaje de la caja de engranajes ...................................................29
Ensamblaje de la sección de líquidos ..................................................30
Ensamblaje de bajo carro ........................................................................32
Ensamblaje de la carro ..............................................................................33
Etiquetas ........................................................................................................33
Registro del producto ...............................................................................34
Esquema eléctrico ......................................................................................34
Accesorios .....................................................................................................35
Garantía .......................................................................................... 36
Español
20 © Titan Tool Inc. Todos los derechos reservados.
Procedimiento para aliviar la presión
No deje de seguir el procedimiento para aliviar la
presión cuando apague la unidad por cualquier motivo,
incluso el servicio o ajuste de alguna pieza del sistema
de rociado, cambio o limpieza de las puntas rociadoras
o la preparación para la limpieza.
1. Bloquee la pistola mueva el seguro del gatillo de la pistola a la
posición bloqueada.
2. Apague la unidad moviendo el interruptor de ON/OFF a la
posición OFF.
3. Gire la perilla de control de presión en sentido antihorario a su
posición OFF en la zona negra.
4. Desbloquee la pistola girando el seguro del gatillo de la
pistola a la posición liberada.
5. Sostenga rmemente la parte metálica
de la pistola contra el lado de un
recipiente metálico para conectar a
tierra la pistola y evitar la acumulación
de electricidad estática.
6. Accione el gatillo para aliviar toda
presión que haya quedado en la manguera.
7. Bloquee la pistola mueva el seguro
del gatillo de la pistola a la posición
bloqueada.
8. Mueva hacia abajo la válvula PRIME/
SPRAY a la posición PRIME.
Mantenimiento
Antes de proceder, siga el Procedimiento de alivio de
presión presentado anteriormente en este manual.
Además, siga todas las otras advertencias para reducir
el riesgo de una lesión por inyección, lesiones por
piezas en movimiento o choque eléctrico. ¡Siempre
desenchufe el rociador antes de darle servicio!
Notas generales de reparación y servicio
Se necesitan las herramientas siguientes para reparar el rociador:
Destornillador Phillips Llave hexagonal de 3/8 de pulgada
Alicates de punta Llave hexagonal de 5/16 de pulgada
Llave ajustable Llave hexagonal de 1/4 de pulgada
Mazo de goma Llave hexagonal de 3/16 de pulgada
Destornillador de paleta Llave hexagonal de 5/32 de pulgada
Llave hexagonal de 5/64 de pulgada
1. Antes de reparar alguna parte del rociador, lea
minuciosamente las instrucciones, incluidas todas las
advertencias.
IMPORTANTE: Nunca tire del cable para desconectarlo. Al
hacerlo podría soltarse el conector del cable.
2. Pruebe su reparación antes de usar rociador normalmente
para vericar que se haya resuelto el problema. Si el rociador
no funciona bien, revise el procedimiento de reparación para
determinar si todo se ha realizado en forma correcta. Consulte
los cuadros de Solución de problemas para ayudar a identicar
otros problemas posibles.
3. Compruebe que el área de servicio esté bien ventilada
en caso de que se estén utilizando solventes durante la
limpieza. Al hacer el mantenimiento siempre use gafas de
protección. Puede que se necesite equipo protector adicional
dependiendo del tipo de solvente de limpieza. Siempre pida
recomendaciones al proveedor de solventes.
4. Si tiene otras preguntas referentes al rociador Titan, llame a
Titan:
Servicio al cliente (EE.UU.) ................................ 1-800-526-5362
Reemplazo del motor
1. Siga el “¨Procedimiento de alivio de presión” y desenchufe la
unidad.
2. Suelte y retire los dos tornillos de la cubierta del motor. Quite
la cubierta del motor.
3. Suelte y retire los tres tornillos de la vientre pan. Quite la
vientre pan.
4. En la parte posterior del motor, desconecte el alambre
proveniente del potenciómetro el alambre procedente de los
transductores. Desconecte los dos alambres procedentes de
la placa del panel de control. (consulte el esquema eléctrico
en la sección de la Lista de piezas de este manual).
5. Retire los cuatro tornillos de montaje del panel de control.
Retire el panel de control para el acceso al panel de control
bordo.
6. En el panel de control bordo, desconecte los dos alambres
procedentes del motor. (consulte el esquema eléctrico en la
sección de la Lista de piezas de este manual).
7. Suelte y retire los cuatro tornillos de montaje del motor..
8. Extraiga el motor de la caja de la bomba.
NOTA: Si el motor no se libera de la caja de la bomba:
• Retire la placa de cubierta frontal.
• Usando un mazo de goma, golpee cuidadosamente
en la parte frontal del cigüeñal del motor que se
extiende a través de la vara conectora.
9. Una vez retirado el motor, inspeccione para ver si hay daños o
desgaste excesivo de los engranajes en la caja de la bomba. Si
es necesario reemplace los engranajes.
10. Instale el motor nuevo en la caja de la bomba.
11. Asegure el motor con sus cuatro tornillos de montaje.
12. Vuelva a conectar los alambres (consulte el esquema eléctrico en
la sección de la Lista de piezas de este manual).
13. Coloque el panel de control de la bomba de vivienda y seguro
en la posición con los cuatro tornillos de montaje del panel de
control.
14. Instale la vientre pan. Asegure la vientre pan con los tres
tornillos correspondientes.
15. Coloque la cubierta del motor. Asegure la cubierta del motor
con los dos tornillos correspondientes.
Motor
Tornillo de
montaje
del motor
Tornillo de
cubier
ta del
motor
Vientre pan
Tornillo de
vientre pan
Tornillo de la
cubierta frontal
Cubierta frontal
Cubierta del motor
Panel de
control
Torillo de montaje
del panel de control
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Titan Impact 440 Manuel utilisateur

Catégorie
Pulvérisateur de peinture
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues