Zhejiang Jiecang Linear Motion Technology JCHR35H6E1 Manuel utilisateur

Taper
Manuel utilisateur
JCHR35H6E1 Remote control User manual
1Remote control Effect Picture
2Remote control function description
2.1 Pairing:
Remote control pair code:
1) put the battery into the remote control.
2) power the control box (supporting our control box).
3) at the same time, hold down the head up button on the remote control and the foot up button.
When the LED on the control box to be matched stops flashing and the buzzer makes a sound, the
pairing operation is completed. To test whether or not the pairing is successful, head up/down, foot
up and down keys, buttons and so on related to drive, if you can hear the "tick" sound emitted by
the relay, specification matching success. Otherwise, repeat all the above steps.
Note: after successful code alignment, operate any two buttons at the same time during use, and
the remote control will not send signals.
3Function description
3.1 Learning function:
After the controller is powered on or long press the learning button, it enters the learning state.
The green light of the controller keeps flashing. In the learning state, press the "head up" and "foot
up" buttons of the remote control at the same time until the controller will emit a "tick". At the
same time, the blue backlight of the remote control flashes twice to indicate that the learning is
completed, and the green light of the controller stops flashing.
3.2 Buttons function:
There are fifteen keys on the hand controller, “head up”, “head down”, “foot up”,foot down”,
neck up”, “neck down”, “M1 /M2”, “Flat”, “ZG”, “Anti snore”, “Under-bed lighting”, head
massage”, “foot massage” andStop” .
“Head up”, “head down”, “foot up”, “foot down”, “neck up” and neck down”: press the button to
press the corresponding push rod action, release the key, and the push rod stops action;
M1/M2 button: Press M1 or M2 button (less than 3s) and release, actuator will move to
programmed position. During this process, press any button that related to the actuator, the
moving action will be stopped. If press any button that not related to the actuator (such as
Under-bed lighting, massage), actuator will stop moving and begin to perform the button’s
function.
The way to set the programmed position: Adjust M1, M2 and M3, M4 to the position you liked,
press and hold the M1/M2 button in 3s, you will hear a beep sounds from control box, the remote
backlit flashes twice, programmed position is set successfully.
P.S. When the actuators are moving to programmed positions such as FLAT/ZG/ANTI
SNORE/M1/M2, if there are more than 2 actuators, the head actuators will move to the
programmed position first, then M3/M4 actuator begin to move. It means, when actuators are
moving to the programmed position, at most 2 actuators can move at the same time.
FLAT button: Press FLAT, actuator begin to lower, until the actuators arrive in the lowest position.
During this process, press any button (such as under-bed lighting, massage., etc.) the actuator will
stop moving, and begin to perform the button’s function.
ZG/ANTI SONRE Buttons Press ZG or ANTI-SNORE button, actuator will move to
corresponding position. During this process, press any button that related to the actuator, the
moving action will be stopped. If press any button that not related to the actuator (such as
Under-bed lighting, massage), actuator will stop moving and begin to perform the buttons
function.
Under-bed lighting Buttons: Press the button to turn on/turn off the under-bed light. When the
light is in turn on state, if user didnt press the button in 10 min, the light will turn off
automatically.
Massage Button: When the head/foot massage motors are turned off, press head or foot massage
button, the head or foot massage will begin to vibrate at the first vibration level. Once press the
massage button, the vibration level will increase one gear. When the vibration strength reaches the
third gear, the massage will turn off. It means, the massage operates with the round cycle
0-1-2-3-0.
Stop Button: Press the button to turn off the massage.
3.3 Dial switch:
The dial switch has three gears in total: left (gear A) - middle (gear AB) - right (gear B). When
learning, dial A or B to learn bed A or bed B respectively. When controlling, dial A to control bed
A, dial B to control bed B, and dial AB to control bed A and bed B at the same time.
3.4 Low power consumption function: when the button is pressed, the remote control starts to
work, and the backlight lights up. If the button is not pressed for more than ten seconds, the
remote control enters into low power consumption, and the backlight goes out.
4Key value to code table
Remote control
pictures
Button icon
key definitions
key value
Remarks
M1
push rod up
0X01
M1
push rod down
0X04
M2
push rod up
0X02
M2
push rod down
0X05
M3
push rod up
0X14
M3
push rod down
0X15
FLAT location
0X08
ZG location
0X07
Memory location A
0X0A
Memory location B
0X0C
Under-bed lighting
0X13
Antisnore location
0X09
Foot massage
0X0F
Head massage
0X0D
Massage stop
0X0E
5Others
5.1. The operating frequency range 2404MHZ~2479MHZ;
5.2. Maximum RF output power of the product:
The overall power of the remote control is 83.88 dBμV/m.
5.3. Number of working channels of remote control is 52404,2419,2454,2469,2479.
And 2479 is the code channel.
6Remark
AFCC 15.21 Information to user
Please note that changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
BFCC 15.19 Information to user
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
CRSS-Gen 8.4 User Manual Notice for Licence-Exempt Radio Apparatus
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation,
Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the
following two conditions:
(1) This device may not cause interference; and (2) This device must accept any interference,
including interference that may cause undesired operation of the device.
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR
d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio
exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :
(1)L’appareil ne doit pas produire de brouillage;
(2)L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Zhejiang Jiecang Linear Motion Technology JCHR35H6E1 Manuel utilisateur

Taper
Manuel utilisateur