DRAKE DQT1000 Manuel utilisateur

Taper
Manuel utilisateur

Ce manuel convient également à

Instruction Manual
TM is a trademark of R.L. Drake LLC
is a registered trademark of R.L. Drake LLC
© Copyright 2010 R.L. Drake LLC P/N: 3852511_D-03-2010 Printed in U.S.A.
MEQ1000 Hybrid QAM Modulator
DTD1000 Digital Tuner and Demodulator Module
SDE24 Encoder module
ASII ASI Input Module
ENTER
0.000 Mbits/S
QAM OUTPUT
MEQ1000 Multiplexing Edge QAM Modulator
SELECT
2 Caution Statements
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT
TO RAIN OR MOISTURE.
DO NOT OPEN THE CABINET, REFER SERVICING TO QUALIFIED PERSONNEL ONLY.
TO PREVENT ELECTRIC SHOCK, DO NOT USE THIS (POLARIZED) PLUG WITH AN EXTENSION
CORD RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY INSERTED TO
PREVENT BLADE EXPOSURE.
POUR PREVENIR LES CHOCS ELECTRIQUES, NE PAS UTILISER CETTE FICHE POLARISEE
AVEC UN PROLONGATEUR, UNE PRISE DE COURANT OU UNE AUTRE SORTIE DE COUR-
ANT, SAUF SI LES LAMES PEUVENT ETRE INSEREES A FOND SANS EN LAISSER AUCUNE
PARTIE A DECOUVERT.
WARNING:
CAUTION:
ATTENTION:
A product and cart combination should be moved
with care. Quick stops, excessive force and uneven
surfaces may cause the product and cart combina-
tion to overturn.
The lightning flash with arrow head symbol, within
an equilateral triangle, is intended to alert the user
to the presence of uninsulated "dangerous voltage"
within the product's enclosure that may be of
sufficient magnitude to constitute a risk of electric
shock to persons.
The exclamation point within an equilateral triangle
is intended to alert the user to the presence of
important operating and maintenance (servicing)
instructions in the literature accompanying
the product.
CAUTION
WARNING: TO PREVENT FIRE OR
ELECTRICAL SHOCK DO NOT
EXPOSE TO RAIN OR MOISTURE
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC
SHOCK,
DO NOT REMOVE COVER
NO USER-SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED PERSONNEL
The MEQ1000 and its associated input modules have been designed to comply with, and tested to
confirm compliance to, the following satety regulations:
ANSI/UL 60065, 7th Edition, dated 06/30/2004, rev. 11/20/2006.
CAN/CSA - C22.2 No. 60065:03 (2006).
Important Safety Instructions 3
Consignes importantes de sécurité 3
1. Read Instructions—All the safety and operating Instructions should be read
before the product is operated.
1a. Lire les directives -Toutes les directives de sécurité et d’utilisation
devraient être lues avant de mettre l’appareil en opération.
2. Retain Instructions—The safety and operating instructions should be
retained for future reference.
2a. Conserver les directives – Les directives de sécurité et d’utilisation
devraient être conservées pour consultation future.
3. Heed Warnings—All warnings on the product and in the operating
instructions should be adhered to.
3a. Tenir compte des avertissements –Tous les avertissements apparaissant
sur l’appareil et dans les consignes d'utilisation devraient être respectés.
4. Follow instructions - All operating and use instructions should be followed.
4a. Suivre les directives - Toutes les directives d’opération et d'utilisation
devraient être suivies.
5. Cleaning—Unplug this product from the wall outlet before cleaning. Do not
use liquid cleaners or aerosol cleansers. Use a damp cloth for cleaning.
5a. Nettoyage – Débrancher l’appareil de la prise électrique murale avant le
nettoyage. Ne pas utiliser de nettoyants liquides ou aérosols. Employer un linge
humide pour le nettoyage.
6. Attachments—Do not use attachments that are not recommended by the
product manufacturer as they may cause hazards.
6a. Fixation – Ne pas utiliser d’autres fixations que celles recommandées par le
manufacturier; elles pourraient être source de dangers.
7. Water and Moisture—Do not use this product near water—for example,
near a bathtub, wash bowl, kitchen sink or laundry tub; in a wet basement; or
near a swimming pool; and the like.
7a. Eau et humidité – Ne pas utiliser cet appareil près de l’eau. Par exemple,
près d'une baignoire, d’un bac de lavage, d'un évier de cuisine ou d'une cuvette
de lessivage; dans un sous-sol humide; ou à proximité d'une piscine; et autres
environnements similaires.
8. Accessories—Do not place this product on an unstable cart, stand, tripod,
bracket, or table. The product may fall, causing serious injury to a child or adult
and serious damage to the product. Use only with a cart, stand, tripod, bracket,
or table recommended by the manufacturer, or sold with the product. Any
mounting of the product should follow the manufacturer's instructions, and
should use a mounting accessory recommended by the manufacturer.
8a. Accessoires – Ne pas installer cet appareil sur un chariot, un socle, un
trépied, un support ou une table instables. L’appareil pourrait tomber, entraînant
des blessures graves à un enfant ou à un adulte, et des dommages importants à
l’appareil. Employer seulement avec un chariot, un socle, un trépied, un support,
ou une table recommandés par le fabricant ou vendu avec l’appareil. Toute
installation de l’appareil devrait être conforme aux directives du manufacturier et
devrait utiliser des accessoires d’installation recommandés par celui-ci.
9. A product and cart combination should be moved with care. Quick stops,
excessive force, and uneven surfaces may cause the product and cart
combination to overturn.
9a. Un chariot supportant l’appareil devrait être déplacé avec précaution. Les
arrêts brusques, la force excessive et les surfaces inégales peuvent renverser le
chariot.
10. Ventilation—Slots and openings in the cabinet are provided for ventilation
and to ensure reliable operation of the product and to protect it from
overheating, and these openings must not be blocked or covered. The
openings should never be blocked by placing the product on a bed, sofa, rug,
or similar surface. This product should not be placed in a built-in installation
such as bookcase or rack unless proper ventilation is provided or the
manufacturer's instructions have been adhered to.
10a. Ventilation – Des fentes et ouvertures dans le châssis sont prévues pour
la ventilation de l’appareil, pour en assurer la fiabilité d’opération et le protéger
contre la surchauffe. Ces ouvertures ne doivent pas être bloquées ou
recouvertes. Ces ouvertures ne devraient jamais être bloquées en plaçant
l’appareil sur un lit, un sofa, une couverture, ou une surface semblable. Cet
appareil ne devrait pas être installé dans un meuble encastré comme une
bibliothèque ou une étagère à moins de lui fournir une ventilation adéquate ou
que l’installation soit conforme aux directives du manufacturier.
11. Power Sources—This product should be operated only from the type of
power source indicated on the marking label. If you are not sure of the type of
power supplied to your home, consult your product dealer or local power
company. For products intended to operate from battery power, or other
sources, refer to the operating instructions.
11a. Sources d’alimentation électrique - Cet appareil devrait être utilisé
seulement avec le type d’alimentation électrique inscrite sur l’étiquette. Si vous
n'êtes pas certain du type d’alimentation électrique fourni à votre maison,
consultez le vendeur de l’appareil ou l’entreprises d'énergie locale. Pour des
appareils alimentés par une batterie ou d'autres sources, se référer aux
consignes d'utilisation.
12. Grounding or Polarization—This product may be equipped with a
polarized alternating-current line plug (a plug having one blade wider than the
other) This plug will fit into the power outlet only one way. This is a safety
feature. If you are unable to insert the plug fully into the outlet, try reversing the
plug. If the plug should still fail to fit, contact your electrician to replace your
obsolete outlet. Do not defeat the safety purpose of the polarized plug.
Alternate Warnings—If this product is equipped with a three-wire grounding-type
plug, a plug having a third (grounding) pin, the plug will only fit into a grounding-
type power outlet. This is a safety feature. If you are unable to insert the plug into
the outlet, contact your electrician to replace your obsolete outlet. Do not defeat
the safety purpose of the grounding-type plug.
12a. Mise à la terre ou polarisation - Cet appareil peut être équipé d'une fiche
électrique de courant alternatif polarisée (une fiche ayant une lame plus large
que l'autre). Cette fiche ne s’insérera correctement dans la prise de courant que
d’une seule façon; c'est un dispositif de sécurité. S’il est impossible d’insérer la
fiche entièrement dans la prise de courant, essayer de renverser la fiche. Si la
fiche ne s’insère toujours pas, contacter un électricien pour remplacer la prise
de courant désuète. Ne pas altérer le dispositif de sécurité de la fiche polarisée.
Mise en garde supplémentaire - Si cet appareil est équipé d'une fiche électrique
à trois broches (une fiche ayant une broche de mise à la terre), la fiche
s'insérera seulement dans une prise de courant équipée d’une mise à la terre;
c'est un dispositif de sécurité. S’il est impossible d’insérer la fiche dans la prise
de courant, contacter un électricien pour remplacer la prise de courant désuète.
Ne pas altérer le dispositif de sécurité de la fiche avec mise à la terre.
13. Power-Cord Protection—Power-supply cords should be routed so that they
are not likely to be walked on or pinched by items placed upon or against them,
paying particular attention to cords at plugs, convenience receptacles, and the
point where they exit from the product.
13a. Protection du cordon d’alimentation - Les cordons d’alimentation
devraient être disposés de façon à ce qu’on ne puisse marcher dessus ou qu’ils
soient susceptibles d’être coincés par des articles placés sur ou contre eux. Une
attention particulière doit être portée aux fiches, prises de courant, et aux points
où ils sortent de l’appareil.
14. Outdoor Antenna Grounding—If an outside antenna or cable system Is
connected to the product, be sure the antenna or cable system is grounded so
as to provide some protection against voltage surges and built-up static
charges. Article 810 of the National Electrical Code, ANSI/NFPA 70, provides
information with regard to proper grounding of the mast and supporting
structure, grounding of the lead-in wire to an antenna discharge unit, size of
grounding conductors, location of antenna-discharge unit, connection to
grounding electrodes, and requirements for the grounding electrode.
See Figure A.
14a. Mise à la terre de l’antenne extérieure - Si un système extérieur
d'antenne ou de câble est relié à l’appareil, s’assurer que le système d'antenne
ou de câble est muni d’une mise à la terre afin de fournir une certaine protection
contre les surtensions et les charges d’électricité statique. L'article 810 du code
électrique national, ANSI/NFPA 70, fournit l'information nécessaire en ce qui
concerne la mise à la terre appropriée du mât et de la structure porteuse, la
mise à la terre du câble de connexion à une unité de décharge d’antenne, le
calibre des conducteurs de mise à la terre, la location de l’unité de décharge
d’antenne, le raccordement aux électrodes de mise à la terre et les
spécifications pour les électrodes de mise à la terre.
Voir la figure A.
15. Lightning—For added protection for this product during a lightning storm,
or when it is left unattended and unused for long periods of time, unplug It from
the wall outlet and disconnect the antenna or cable system. This will prevent
damage to the product due to lightning and power-line surges.
15a. Foudre - Pour une protection supplémentaire de cet appareil pendant un
orage électrique, ou quand il est laissé sans surveillance et inutilisé pendant de
longues périodes, le débrancher de la prise électrique murale et déconnecter le
système d'antenne ou de câble. Ceci préviendra les dommages à l’appareil dus
à la foudre et aux surtensions.
16. Power Lines—An outside antenna system should not be located in the
vicinity of overhead power lines, other electric light or power circuits, where it
can fall into such power lines or circuits. When installing an outside antenna
system, extreme care should be taken to keep from touching such power lines
or circuits as contact with them may be fatal.
16a. Lignes électriques - Un système d'antenne extérieur ne devrait pas être
situé à proximité de lignes électriques aériennes ou de tout autre circuit
électrique, où il pourrait tomber sur de tels circuits ou lignes électriques. Lors de
l’installation d’un système d’antenne extérieur, d’extrêmes précautions devraient
être prises afin de prévenir tout contact avec des lignes ou circuits électriques.
Entrer en contact avec de tels circuits ou lignes électriques pourrait être fatal.
17. Overloading—Do not overload wall outlets, extension cords, or integral
convenience receptacles as this can result in a risk of fire or electric shock.
17a. Surcharge – Ne pas surcharger les prises de courant murales, les
rallonges électriques ou les prises de courant intégrées. Un risque d’incendie ou
de choc électrique pourrait résulter d’une telle surcharge.
4 Important Safety Instructions (cont.)
4 Consignes importantes de sécurité
18. Object and Liquid Entry—Never push objects of any kind into this product
through openings as they may touch dangerous voltage points or short-out parts
that could result in a fire or electric shock. Never spill liquid of any kind on the
product.
18a. Insertion d’objet ou de liquide – Ne jamais insérer d’objet par les
ouvertures de cet appareil. Il pourrait toucher des points de voltage dangereux
ou court-circuiter des pièces, ce qui pourrait résulter en incendie ou en choc
électrique. Ne jamais verser de liquide sur l’appareil.
19. Servicing—Do not attempt to service this product yourself as opening or
removing covers may expose you to dangerous voltage or other hazards. Refer
all servicing to qualified service personnel.
19a. Entretien –Ne pas essayer de faire soi-même l’entretien de cet appareil.
En ouvrir ou en retirer les couvercles pourrait vous exposer à des voltages
dangereux ou à d’autres dangers. Confier tout entretien à un personnel de
service qualifié.
20. Damage Requiring Service—Unplug this product from the wall outlet and
refer servicing to qualified service personnel under the following conditions:
a. When the power-supply cord or plug is damaged,
b. If liquid has been spilled, or objects have fallen into the product,
c. If the product has been exposed to rain or water,
d. If the product does not operate normally by following the operating instruc-
tions. Adjust only those controls that are covered by the operating
instructions as an improper adjustment of other controls may result in damage
and will often require extensive work by a qualified technician to restore the
product to its normal operation,
e. If the product has been dropped or damaged in anyway, and
f. When the product exhibits a distinct change in performance—this indicates a
need for service.
20a. Dommage exigeant un entretien - Débrancher cet appareil de la prise de
courant électrique et confier l'entretien au personnel de service qualifié dans les
éventualités suivantes:
a. Quand le cordon d’alimentation ou sa fiche sont endommagés,
b. Si des objets sont tombés dans l’appareil, ou si du liquide y a été renversé,
c. Si l’appareil a été exposé à la pluie ou à l'eau,
d. Si l’appareil ne fonctionne pas normalement en suivant les consignes
d'utilisation.
Ajuster seulement les commandes qui sont mentionnées dans le guide
d'opération. Un mauvais ajustement des autres commandes pourrait causer des
dommages à l’appareil et souvent exiger un travail supplémentaire de la part
d’un technicien qualifié pour remettre l’appareil en état normal d’opération.
e. Si l’appareil a été échappé ou endommagé de n’importe quelle façon, et
f. Quand l’appareil montre un changement notable de performance – ceci
indique qu’un entretien est nécessaire.
21. Replacement Parts—When replacement parts are required, be sure the
service technician has used replacement parts specified by the manufacturer
or have the same characteristics as the original part. Unauthorized substitutes
may result in fire, electric shock or other hazards.
21a. Pièces de rechange - Si des pièces de rechange sont nécessaires,
s’assurer que le technicien de service a employé des pièces de rechange
spécifiques du manufacturier ou ayant les mêmes caractéristiques que les
pièces originales. L’utilisation de pièces de rechange non autorisées pourrait
résulter en incendie, choc électrique ou autres dangers.
22. Safety Check—Upon completion of any service or repairs to this product,
ask the service technician to perform safety checks to determine that the
product is in proper operating condition.
22a. Vérification de sécurité – À la suite de toute réparation ou entretien de
cet appareil, demander au technicien de service d'exécuter des vérifications de
sécurité afin de s’assurer que l’appareil est en condition normale de
fonctionnement.
23. Wall or Ceiling Mounting—The product should be mounted to a wall or
ceiling only as recommended by the manufacturer.
23a. Montage au mur ou au plafond - L’appareil ne devrait être monté au mur
ou au plafond qu’uniquement de la façon recommandée par le manufacturier.
24. Heat—The product should be situated away from heat sources such as
radiators, heat registers, stoves, or other products (including amplifiers) that
produce heat.
24a. Chaleur – L’appareil devrait être situé loin de sources de chaleur telles que
des radiateurs, des registres de chaleur, des fourneaux, ou d'autres appareils (y
compris amplificateurs) produisant de la chaleur.
GROUND CLAMPS
ATTACHES DE MISE À LA
TERRE
GROUNDING CONDUCTORS
(NEC SECTION 810-21)
CONDUCTEURS DE MISE À LA
TERRE
ANTENNA DISCHARGE UNIT
(NEC SECTION 810-20)
UNITÉ DE DÉCHARCHE
D’ANTENNE
ANTENNA LEAD IN WIRE
CÂBLE DE CONNEXION DE
L’ANTENNE
ELECTRIC
SERVICE
EQUIPMENT
GROUND CLAMP
NEC - NATIONAL ELECTRIC CODE
NEC – CODE ÉLECTRIQUE NATIONAL
Figure A
Example of antenna grounding as per National Electrical Code, ANSI/NFPA 70
Exemple de mise à la terre d’antenne selon le code électrique national, ANSI/NFPA 70
NOTE TO CATV SYSTEM INSTALLERS:
THIS REMINDER IS PROVIDEO TO CALL THE
CATV SYSTEM INSTALLER'S ATTENTION TO
ARTICLE 820 - 40 OF THE NEC THAT PROVIDES
GUIDELINES FOR PROPER GROUNDING AND,
IN PARTICULAR, SPECIFIES THAT THE CABLE
GROUND SHALL BE C0NNECTED TO THE
GROUNDING SYSTEM OF THE BUILDING, AS
CLOSE TO THE POINT OF CABLE ENTRY AS
PRACTICAL.
NOTE AUX INSTALLATEURS DE SYSTÈME DE
CATV :
CE RAPPEL EST FOURNI POUR PORTER À
L’ATTENTION DES INSTALLATEURS DE
SYSTÈME DE CATV, L'ARTICLE 820 - 40 DU NEC
QUI DONNE DES DIRECTIVES POUR UNE MISE
À LA TERRE APPROPRIÉE ET, EN
PARTICULIER, SPÉCIFIE QUE LE CÂBLE DE
MISE À LA TERRE DEVRAIT ÊTRE RACCORDÉ
AU SYSTÈME DE MISE À LA TERRE DU
BÂTIMENT LE PLUS PRÈS POSSIBLE DE
L’ENTRÉE DU CÂBLE.
POWER SERVICE GROUNDING
ELECTRODE SYSTEM (NEC
ART 250. PART H)
SYSTÈME DE MISE À LA TERRE
DU BÂTIMENT
Table of Contents / Specifications 5
Specifications subject to change without notice or obligation.
TABLE OF CONTENTS
Input Module
54 to 1000 MHz.
Std. CATV, HRC, IRC, or
Broadcast
6 MHz.
-33 dBmV to +35 dBmV,
8VSB
-22 dBmV to +35 dBmV, 64
QAM
-17 dBmV to +35 dBmV, 256
QAM
75 Ohms
> 6 dB, Broadcast mode; >
12 dB, CATV mode.
80 dB.
40 dB
< 9 dB, Broadcast mode; <
12 dB, CATV mode.
8VSB - ATSC
64QAM, 256QAM, - ITUB,
CATV mode.
10.76 MS/s, 8VSB; 5.057
MS/s, 64QAM; 5.3606MS/s,
256 QAM
SPECIFICATIONS
2 Caution Statements
3 Important Safety Instructions
5 Table of Contents / Specifications
6 General Description
7 Installation and Mounting / Front Panel Controls
8 Rear Panel Controls and Connections
9 Setup and Programming / Software Flow Chart
12 Setup and Programing (Continued) / Operation
13 Operating Instructions for Drake Digital Headend Program
14 Additional Information
15 CATV Channel Frequencies
16 Broadcast TV Channel Frequencies
17 Service / If You Need To Call For Help
18 Warranty
DTD1000 DEMODULATOR (S)
Input Frequency Range:
Channel Plans (Menu selectable)
:
Input Channel Bandwidth:
Input RF Level Range:
Input Impedance:
Input Return Loss:
Image rejection:
Adjacent Channel Rejection:
Noise Figure:
Demodulation Modes:
Symbol Rates:
SDE24 DUAL PROGRAM ENCODER MODULE
Analog Interface
Composite video Inputs
Composite Video Input Level
S Video Inputs
Composite or S Video select
Audio Inputs, for 2 programs
Audio Input Level
MPEG Encoder
Encode Format - #1 input
Encode Format - #2 input
2 composite inputs, one for
each program
1 Volt p-p ± 3 dB
2 S Video connectors, one
for each program
User selectable for each
program input
RCA type for L and R audio
channels, 2 sets
1 Vrms or 2 Vrms user
selectable and user
adjustable audio gain ± 15dB
MPEG2 or MPEG4 H.264,
selectable
MPEG2 only
Encoding Bitrate
Video Adjustments
Audio Encoder
Selectable types
AC3 Encoder
Output bitrate
Output
Constant Bitrate: 1 Mbps to
8 Mbps
Brightness, Contrast,
Saturation, Hue
AC3 - Dolby digital Stereo
OR
MP2 - MPEG1, Layer 2
Manufactured under license
from Dolby Laboratories.
320 kbps
The output of each SDE24
module is connected
internally to the multiplexers
that are included in the
MEQ1000 chassis.
ASII ASI INPUT
ASI Input Clock:
ASI Input Data Rate:
MEQ1000
Modulation Modes:
Symbol Rate:
FEC:
I/Q Phase Error:
Carrier Suppression:
Channel Amplitude Error:
MER:
MEQ1000
Output Frequency Range:
Channel Plan:
Frequency Stability:
Maximum Output Level:
Minimum Output Level:
Output Level Accuracy:
Output Impedance:
Spurious Outputs:
Broadband Noise:
Phase Noise:
MEQ1000
Data Link:
RS232 Input:
RS232 Output:
MEQ1000
GENERAL
Power:
Weight:
Size:
Operating Temperature:
SPECIFICATIONS (Continued)
Input Module
270 MHz
Maximum of 80 Mbps per ASII module.
QAM Modulator
16QAM, 32QAM, 64QAM, 128QAM,
256QAM, 512QAM or 1024QAM.
1 Ms/s to 7 Ms/s.
ITUA (DVB) or ITUB (DigiCipher).
Less than 1 degree.
45 dB.
Less than 1 dB.
Greater than 38 dB with blind equalizer.
Upconverter RF Output
54 MHz to 1002 MHz.
Std. CATV, HRC, IRC, or Broadcast
± 5 ppm.
+ 61 dBmV minimum, adjustable
downward.
+ 45 dBmV.
± 1 dB.
75 Ohms with return loss better than 14
dB (within output filter passband).
-60 dBc from 40 MHz to 1000 MHz.
Less than -12 dBmV (6 MHz BW @ ±12
MHz).
-101 dBc @ 10 kHz offset
RS232 Control
2400, 4800, 9600, or 19,200 baud
interface via serial cable.
DB-9 connector for connection to
modem or PC.
DB-9 connector for connection to
addtional transcoders.
ASI OUTPUT
The ASI output provides a copy of the
transport stream that is input to the QAM
modulator.
90 - 132 VAC/ 60 Hz, 35 W maximum.
9.5 pounds
19” W x 1.75” H x 14.5” D.
0 degrees C to + 50 degrees C
6 General Description
GENERAL DESCRIPTION
The R.L. Drake model MEQ1000 is a commercial grade hybrid
QAM modulator. The MEQ1000 features plug in input modules
that include an ATSC/QAM tuner, an ASI input, an IP input, and
analog NTSC inputs; thus the description 'hybrid' is used to
describe it. A multiplexer is built in to combine the transport
streams and input the filtered and groomed transport stream to
the QAM modulator. This manual includes the SDE24 Dual
Program Encoder Module, the DTD1000 input module and ASII.
Other input modules will have instructions provided with them.
Each commercial quality SDE24 module contains two encoders
and if MPEG2 encoding is desired for two programs, two MPEG2
transport streams can be generated. If MPEG4, H.264 encoding
is desired, each SDE24 module can encode one program to an
H.264 output stream. Another option is to encode one program in
MPEG2 and another program in H.264
Each SDE24 module provides two sets of input connectors for
NTSC composite or S-video with stereo audio. Audio is encoded
using Dolby AC-3 encoding.The SDE24 encoder modules provide
standard definition encoding. The SDE24 encoders accept
analog NTSC video input from either composite or S video
sources and provide commercial quality MPEG2 or H.264, 480i
video outputs in both DVB-ASI and RF QAM.
The MEQ1000 has two input module slots and the outputs
interface to the MEQ1000 multiplexer, internally, where they are
MPEG program filtered, multiplexed, and groomed. Programs,
among the total group from input module A and input module B,
may be selected or not selected by the operator to be sent to the
QAM modulator. Each input must contain no more than 20
programs and a maximum of 20 programs per input may be
selected. Also, the total bitrate of the selected programs must not
exceed that of the output QAM channel capacity.
Some common applications include: drop/add, cherry picking
programs from ASI or IP MPTS inputs, digital channel processing,
or local origination additions.
The MEQ1000 contains a high performance QAM modulator that
can operate in most ITU-A or ITU-B modes up through 1024
QAM. The very low noise, high output, upconverter provides
coverage from 54 MHz to 1002 MHz while maintaining exception-
ally low phase noise and broadband noise. Output level can be
selected at a value between + 45 and + 61 dBmV.
The MEQ1000 operates in a fixed output clock mode and
processes null packets when required to maintain the set fixed
clock rate. PCR correction is included.
DIGITAL CHANNEL PROCESSING (One input module)
The DTD1000 input module tunes any 8VSB or QAM channel
between 54 and 1002 MHz. It is ideal for digital 'channel process-
ing' applications where a single digital video signal is received,
error corrected, clocked at a user determined fixed rate and
remodulated on the same or another RF channel. Applications
include cleaning up a low MER QAM signal received from a
CATV source or fiber link receiver, or shifting the RF frequency of
a QAM modulated signal. It may be used to convert one off-air
ATSC 8VSB signal to a QAM output with rate adjustment. Used in
the processor mode with only one input, the DQT1000 can
process ATSC or CATV QAM inputs. No multiplexing or altering
of any MPEG tables is performed in this mode.
Used in the non multiplexing mode, the data rate of the incoming
signal can be any rate that falls within the specification range.
The output rate can be set to any fixed output rate (equal to or
faster than the input rate).
MULTIPLEXING TWO ATSC TRANSPORT STREAMS
Utilizing two DTD1000 input modules, two off-air 19.4 Mbps ATSC
signals (QAM modulated CATV delivered signals could also be
used) can be received and multiplexed to obtain a 38.8 Mbps
256QAM output. Thus two ATSC inputs can be output on a single
6 MHz bandwidth 256 QAM channel.
Another way of combining two ATSC 19.4 Mbps streams is to
receive the first stream using the 8VSB input (DTD1000) and
input the second stream, if available in ASI format, through the
ASII module in the second input slot. Again the two combined
ATSC signals will be modulated at 256QAM in a 6 MHz wide
channel.
If it is desired to provide both ATSC signals from two ASI sources,
two ASII modules can be used.
When the MEQ1000 is used as described above, no loss of
picture or sound packets occurs. There is no added compression
of the video or audio streams. Only the necessary control
packets are rewritten to prevent duplication of MPEG2 program
numbers and major and minor channel number assignments in
the tables.
Using a PC interface, the operator can select the major and minor
program numbers that he desires for each program in the output
multiplex.
PROGRAM FILTERING
A 'Select Program' function is provided to allow the operator to
select which of the MPEG programs present on the A and B input
streams are to be included in the output multiplex.
PSIP OPTIONS
When operating in the multiplex mode, the MEQ1000 can be set
to process PSIP information from both sources and rewrite tables
containing combined PSIP information, or in cases where the off-
air broadcast channels may not be transmitting some or all of the
tables, it can be set to ignore and discard the PSIP tables
completely, or it can be set to generate MGT and VCT tables
without EIT tables. Null packet processing is applied as neces-
sary to keep the output data rate at the desired setting. PCR
correction is provided. The operator can program desired major
and minor channel numbers for each program in the output
stream.
OUTPUTS - RF and ASI
The 54 to 1000 MHz RF output is always QAM regardless of
whether the input is VSB or QAM. This same filtered stream is
also output via the rear panel ASI output jack.
ENTER
0.000 Mbits/S
QAM OUTPUT
MEQ1000 Multiplexing Edge QAM Modulator
SELECT
ENTER
0.000 Mbits/S
QAM OUTPUT
MEQ1000 Multiplexing Edge QAM Modulator
SELECT
Installation & Mounting / Front Panel Controls 7
F1 F2 F5 F6 F7 F8
F3 F4
F1, LCD DisplayThis display presents the selected
menu screen and the parameter settings. The backlight in
the display is on when power is applied.
During operation, the S/N (signal to noise ratios) of the
demodulator input signals are displayed. For 8VSB inputs,
the threshold is about 15 dB. For QAM inputs, the thresh-
old is about 23 dB for 64QAM and 27 dB for 256QAM. You
should maintain a S/N several dB above these thresholds
for reliable operation.
F2, ENTER button – Use the ENTER button to enter the
adjust mode or to save and load a new setting or settings
after adjustment. Hold for 2 seconds until the bottom line of
the display starts to flash to enter the adjust mode. After
entering the adjust mode, momentarily pressing the
ENTER button again will load and save any settings that
may have been changed using the F5 & F6 buttons.
F3 & F4, Left and Right Buttons – Use the left
and right arrow buttons to navigate from screen to screen
to view a parameter setting. These buttons are operational
in the view mode or the adjust mode. Using only these
buttons will not change any parameter settings. After a
short period of button inactivity, the default display will
be returned.
F5 & F6, Up and Down Buttons – Use the down
and up arrow buttons to change the value of a viewed
parameter setting. The unit must be in the adjust mode with
the display flashing in order for these buttons to become
active for changing a parameter setting. If the unit is not in
the adjust mode, pressing the up button will display the
firmware version number or pressing the down button will
display the output QAM symbol rate.
F7 & F8, Select Buttons - Use the left or right
Select arrow buttons to select which section of the unit to
control. Select one of the input modules or the QAM
modulator / up converter section.
INSTALLATION AND MOUNTING NOTES
This equipment is designed to be installed in a standard 19” rack. A built in fan provides air movement through
the unit.
When connecting an incoming RF signal source to two DTD1000 modules, note that the antenna or CATV
source must be connected to both the A and B input connectors. These inputs are kept separate in case the
inputs need to come from different antennas or one antenna and one CATV source.
Connect the AC line cord to an appropriate source of 120 volt, 50/60 Hz AC power. The MEQ1000 is
always on once the AC power cord is connected to its power source.
RF OUTPUT
120 VAC 60 Hz
35 WATTS
AC POWER
RS232
ASI OUTPUT
R
F
I
N
P
U
T
D
T
D
1
0
0
0
IN
OUT
D
T
D
1
0
0
0
R
F
I
N
P
U
T
MEQ1000 - The top illustration is shown above with
ASII ASI Input and DTD1000 Digital Tuner and
Demodulator Modules installed. The ASI connectors
are type BNC female. The ASI input is used to input the
ATSC transport stream in ASI format instead of RF.
The lower illustration shows the MEQ1000 with SDE24 and
ASII modules installed.
R1, RF OUTPUT This is the high level (61 dBmV), 54 to
1002 MHz, output from the MEQ1000 upconverter section.
R2, Ventillation slots. - Do not block air entering these
slots.
R3, Input Module Slot A
R4, Input Module Slot B.
R5, ASI Output - This output delivers the same multi
program transport stream in ASI as is sent to the QAM
modulator.
R6, RS232 in - Connection to a PC or modem for use with
remote control / monitoring program or for firmload
download.
R7, RS232 OUT - Loop to another MEQ1000.
R8, AC Line Cord – For connection to the nominal
120 VAC power source. This unit is designed for use in
R1 R2 R3 R4 R5 R6 R7 R8
countries with 120 VAC power standards but the power
supply will accept an input voltage range of 90 VAC
minimum to 260 VAC maximum with a power line fre-
quency of either 50 or 60 Hz.
R9, ASI Input type BNC connector - Applies to ASII
module, if present. This input is for a 270 MHz clocked
SPTS or MPTS serial input. The maximum data rate is 80
Mbps for a given ASII module.
R10, ASI Loop type BNC connector - Applies to ASII
module, if present. Provides a looped out transport stream
identical to what is input to jack R9.
R11, RF Input type F connector - Applies to DTD1000
module, if present. This is the antenna or CATV source
input.
R12, AUDIO 1 & 2 - These four color coded RCA type
connectors provide audio Left (white) and Right (red) inputs
to the SDE24 Encoder.
R13, VIDEO 1 & 2 - These two RCA type connectors color
coded yellow provide two separate video inputs to the
SDE24 Encoder.
R14, S-VIDEO 1 & 2 - These S-Video type connectors
provide two separate S-Video inputs to the SDE24 En-
coder.
8 Rear Panel Connections
R11
RF OUTPUT
120 VAC 60 Hz
35 WATTS
AC POWER
RS232
ASI OUTPUT
A
S
I
I
N
P
U
T
A
S
I
L
O
O
P
A
S
I
I
IN
OUT
S
D
E
2
4
2
1
A
U
D
I
O
R
L
2
1
2
1
V
I
D
E
O
S
-
V
I
D
E
O
2
1
With Two DTD1000 Modules
With One SDE24 Module and one ASII Module
R12 R13 R14 R10 R9
Setup and Programming / Software Flow Chart 9
Programming and viewing of the various setup and
operating parameters is accomplished using the front panel
back lit, two line, sixteen character wide LCD along with the
two LEFT and RIGHT SELECT buttons and the five LEFT,
RIGHT, UP, DOWN and ENTER buttons. The name of the
parameter is on the top line of the display and the setting
value is on the bottom line.
To observe a certain parameter setting without intending to
change its value, just use the LEFT and RIGHT SELECT
buttons and the LEFT and RIGHT arrow buttons to navi-
gate through the menus shown in the software flow chart
below. The current setting for each parameter is shown on
the bottom line of the display. Note that depending upon
certain settings, some screens are not needed and will be
skipped.
To make a change in the displayed parameter and its setting and
if this is the initial setup, you will want to enter the ‘adjust’ mode.
To do this, press the ENTER button that is located in the center
of the four arrow buttons and hold in for several seconds until
the display begins to flash. After you are in the adjust mode
(bottom line of screen flashing) use the left and right arrows to
navigate among screens and use the up and down arrows to
change the parameter setting. When ENTER is pressed, the
new settings will be loaded and stored and the unit will exit the
‘adjust’ mode. You may wish to not press ENTER until you have
gone through all screens and settings and then press ENTER to
save and load all changes in one step OR you can store just one
or several parameters at a time and reenter adjust mode to set
the next. Either method is acceptable.
SETUP:
UNIT ID
RS-232
BAUDRATE
NORMAL MODE
MEQ1000
MULTIPLEX
SETUP INPUT A:
DTD1000
SETUP INPUT B:
DTD1000
CHANMAP
DTD1000
CHANNEL
DTD1000
MODE
Tuner
AGC
DTD1000
Lock Status
NORMAL MODE
MODE:
DTD1000
CHANNEL:
DTD1000
CHANMAP:
DTD1000
Demodulator
BROADCAST
CATV
IRC
HRC
1 - 158
VSB-8
QAM-64B
QAM-256B
ADJUST MODE
ASII MODULE
MAJOR
TABLE
VCT
PROGRAMS
MPEGINPUT B
BAUDRATE
RS232
UNIT ID
Select
0 - 63
19200
9600
4800
2400
OFFSET
SELECT ALL PROGS
SELECT PROGRAMS
PSIP
OUTPUT CHANNEL
CHANNEL
ADJUST MODE
MULTIPLEX
USE A INPUT ONLY
USE B INPUT ONLY
ENABLED
0 - 90
ENABLED
BASIC MGT/VCT
DISABLED
CVCT
TVCT
USER DEFINED
ORIGINAL CHANNEL
QAM
MODE
QAM-16A
QAM-32A
QAM-64A
QAM-128A
QAM-256A
QAM-512A
ITU-A
QAM-1024A
QAM-64B
QAM-256B
QAM-1024B
ITU-B
SYMRATE
QAM
1.000 -
7.000
CHANNEL
OUTPUT
OUTPUT
CHANMAP
INTERLEAVER
OUTPUT
FORMAT
NORMAL
PRBS15
PRBS15M
PRBS23
PRBS 23M
CW
BROADCAST
CATV
IRC
HRC
1 - 158
RF
LEVEL
45 - 62 dBmV
QAM
PRESET
MANUAL
SYMRATE
GRAY
ENCODING
selected.)
appears only
(This screen
if ITU-A is
DAVIC
DVB
CHANNEL
PSIP
OFFSET
INPUT B MPEG
PROGRAMS
VCT
TABLE
MAJOR
QAM
MODE
ENCODING
GRAY
QAM
SYMRATE
PRESET
QAM
SYMRATE
Mbits/S
INTERLEAVER
LEVEL
RF
FORMAT
OUTPUT
CHANMAP
OUTPUT
OUTPUT
CHANNEL
ENTER
SELECT
if ITU-A is
(This screen
appears only
selected.)
(These screens only appear if MULTIPLEX is ENABLED.)
(These screens only appear if MULTIPLEX is ENABLED.)
Indicates that ASII module is installed.
ASII module has no adjustments.
This chart assumes a
DTD1000 module or a
SDE24 module in
Input - A and an ASII
module is in Input - B.
This could be different.
FORMAT
BITRATE:
RESOLUTIONVIDEO
NORMAL MODE
BITRATE:
FORMAT
VIDEO
S-VIDEO
COMPOSITE
MPEG2
MPEG4 H.264
1 - 8 Mbits/S
PROGRAM MODE
RESOLUTION
720 x 480
704 x 480
528 x 480
480 x 480
352 x 480
353 x 240
BRIGHTNESS
BRIGHTNESS
0 - 255
CONTRAST
0 - 255
CONTRAST SATURATION
HUE
MAX AUDIO IN
AUDIO GAIN
AUDIO GAIN
MAX AUDIO IN
HUE
SATURATION
0 - 255
0 - 2551 Vrms
2 Vrms
MUTE
+ 15 dB to
-15 dB in
1 dB steps
(This screen only appears
for Encoder 1 in a given
SDE24 module. Encoder 2
in that module is always
forced to MPEG2.)
SETUP INPUT A:
SDE24
I128, J1
I128, J2
I64, J2
I128, J3
I132, J4
I128, J4
I16, J8
I128, J5
I8, J16
I128, J6
I4, J32
I128, J7
I2, J64
I128, J8
I1, J128
(This screen
appears only
if ITU-B
is selected.)
AUDIO
ENCODE:Exx
AUDIO
ENCODE:Exx
AC3
MP2
10 Setup and Programming, continued
Choose the SELECT PROGRAMS setting to allow the
operator to pick which programs from the A and B inputs are
to be included in the output multiplex.
NOTE: At this point you may proceed through the remaining
menus, below, before pressing the ENTER button to load the
selected data OR you may press ENTER now and then come
back to the rest of the menus. In any case, when the ENTER
button is pressed, one of the following two actions will occur:
A) If SELECT ALL PROGS has been selected, the MEQ1000
will now read PAT tables from the two input streams and
discover which MPEG programs are defined. If you wish to
view the MPEG program numbers of programs that were
found, follow the procedure below:
VIEWING MPEG PROGRAM NUMBERS
In order to see the MPEG program numbers of incoming
streams, the following procedure can be followed:
1) Press the ENTER button for 2 seconds to enter program
mode. Release button. Display will be flashing.
2) Press the ENTER key again and hold. By continuing to
hold in the ENTER button, the following display will be
slowed down so that program numbers can be read as they
scroll by.
3) A screen will be displayed that indicates:
PMT PROG A xxxx or PMT PROG B xxxx.
4) The xxxx field will be a number that corresponds to the
MPEG program number of a program found in the PMT table
for the indicated (A or B) input. As the button is held, all
entries for input A will scroll past and then entries for input B
will scroll past.
5) Release button and if necessary repeat steps 1 - 4.
B) If SELECT PROGRAMS was chosen, the unit will read
the PAT tables from both inputs and then display:
MPEG PROG XXXXX: (XXXXX is a number from 00001 to
65535) on the top line of the display. Using the right and
left arrow keys, you can scroll through all 65535 possible
program numbers.
Don't be alarmed by the large number of possibilities
because if the arrow key is held down, the scrolling will
speed up so all 65535 possible numbers can be scanned in a
short time - any time an entry is found at a given program
number, the scrolling will slow down to give the operator time
to see it and stop scrolling, if desired. Usually, all programs
are known to be numbered between 01 and 20.
For each MPEG program number, displayed on the top line,
the bottom line, on the right, will indicate A, B, AB, or nothing.
This will indicate that the program number on the top line was
found in input A or B or AB for both or not in either one if
blank.
To select programs to be included in the output multiplex,
use the up and down arrow keys to select NOT SELECTED,
INPUT A, INPUT B, or INPUT A+B. If NOT SELECTED is
used, then this program number will not be present in the
output and any programs with this program number that are
present in the A or B inputs will be filtered out. If INPUT A is
selected, the A input program only is used.
This section provides additional details regarding the
selectable items shown in the ‘adjust’ mode on the
Software Flow Chart on page 8.
SETUP: MEQ1000
UNIT ID: Select the desired unit identification number when
connecting the 'RS232 IN' connector to a PC or modem for
remote control using 'Drake Remote Control Software'.
Numbers 1 thru 63 may be used. If zero (0) is selected, the
PC will ignore the unit.
RS232 BAUD RATE: This setting determines the baud
rate at which the MEQ1000 communicates with the remote
PC. Settings available are 2400, 4800, 9600 and 19,200.
All units 'daisy chained' to the remote PC or modem must
be set to the same baud rate.
MULTIPLEX: This setting determines whether the Input
Module Slot A input is to be multiplexed with a second
input (if installed). Select Input Module Slot A to activate the
A Input Module only. Select Input Module Slot B to activate
the B input module only. To turn on the multiplex function
select ENABLED. If either A or B Input module is selected,
the next menu will be the QAM MODE menu. You may skip
to that paragraph, below.
INPUT B OFFSET: When the Input Module Slot B or ASI
input has been installed and selected in the MULTIPLEX
menu, this menu will be present. Because the two incoming
transport streams are likely to have overlapping use of
MPEG program numbers, the MEQ1000 will pass the
program numbers from input A unchanged and an offset,
equal to the value chosen in this menu, will be added to the
program number of programs from the second input. This
same offset value will also be added to the minor channel
number in the VCT table for programs from the second
input source. Usually an offset of 10 will be adequate but if
you know there are programs in the signal input to input A
using program numbers above 10, a higher offset may be
required. Values between 10 and 90, in increments of 10,
are available for selection. When it is known that there is
no overlap between input A and input B stream program
numbers, a 0 offset setting can be used. Be cautious if this
is the selection that is chosen.
MPEG PROGRAMS: This menu provides selections to
determine which programs are multiplexed to form the new
multiprogram transport stream output that will be supplied
to the QAM modulator section. Choose the SELECT ALL
PROGS setting to multiplex all programs from inputs A
and B up to 20 programs maximum. If more than 20 exist,
you must use SELECT PROGRAMS and only select 20
maximum.
It is the operator's responsibility to be sure that the total
data rate of these programs does not exceed the maxi-
mum data rate for the output QAM mode that will be used,
typically 26.98 Mbps for 64QAM or 38.8 Mbps for 256QAM
in ITUB modes. If the sum of input bitrates would exceed
this amount, or if more than 20 programs are present,
some programs will have to be dropped from the list of
selected programs.
Setup and Programming, continued 11
If INPUT B is selected, the B program is used and A filtered
out. If INPUT A+B is chosen, then both are accepted if
present.
Note: It is OK to use this menu to set up desired program
selections 'off line'. That is, with no actual input at the
present time. Programs may be selected that may not
currently be in the input stream but are desired at some
future time.
Note: It is possible to select both programs with the same
program number - one from A and one from B as long as
the INPUT B offset is set so that the B program number plus
the offset amount does not duplicate a program number
from the A input. The offset is not included in the MPEG
program number display being discussed above but the
offset will be added to all MPEG program numbers from the
B input when they are added to the output multiplex.
PSIP: This menu provides a choice of how the unit
organizes the PSIP information from two ATSC streams that
are being multiplexed.
In the ENABLED setting, information from the MGT and
VCT tables from both signals will be used to build a new
table for the combined output signal. Both input streams
must have these tables present in order for the unit to be
able to perform this operation. EIT tables will be processed
so as to provide program information, if present, for the next
12 hours. This selection is the only one that passes EIT
table program information to the multiplexed output signal.
RRT and STT tables from Demod A are passed through.
If the broadcast station is not transmitting complete MGT
and VCT tables, the ENABLED selection cannot be used. In
this situation, DISABLED may be selected. In DISABLED
mode, the unit does not process or output any MGT, VCT, or
EIT tables. This can be a fine solution for cable systems
that use set top boxes which operate from their own system
channel map and have no need for these tables. MPEG
program information is still processed. Some retail con-
sumer QAM set tops operate perfectly in this mode and
others may not.
The third option is the BASIC MGT, VCT choice. When this
selection is made, the DQT1000 or MQM1000 will build its
own MGT and VCT tables from the incoming streams even
if one or both of the streams do not contain these tables.
This solution should satisfy all types of set top boxes but
will not provide any EIT table program guide information.
The STT and RRT tables from the source are passed
through unchanged in the ENABLED mode and filtered out
in the other modes.
VCT TABLE: This menu is only available when ENABLED
or BASIC MGT, VCT has been selected in the previous
PSIP menu. You may select the TVCT - TV channel table or
CVCT table for CATV. Usually the TVCT choice must be
selected for ATSC input signals.
MAJOR CHANNEL: This menu is not available if PSIP is
disabled. This setting will determine how a channel number
is displayed on a consumer TV if the TV is tuning the output
of the MEQ1000 without a cable box.
When ORIGINAL is selected, the major channel number
indicated in the output tables will be that sent by the original
broadcaster. If OUTPUT CHANNEL is selected, the major
channel number will be set to the channel number of the
MEQ1000 RF output channel. When a cable box is used, it
usually does not require or use this information.
Minor channel numbers are the same as those input via
module A and as input via module B with the offset added to
the B side programs.
When USER DEFINED is selected and the remote control
software is used to allow programming via a PC, then the
MPEG program number and the major and minor virtual
channel numbers may be set to whatever number the
operator chooses providing total flexibility. These numbers
cannot be programmed with the front panel buttons but only
via a PC and the RS232 interface of the MEQ1000.
It is up to the operator to insure that no duplications are
made when using this mode.
QAM MODE: This menu allows the user to set the modula-
tion type for the output. Choices range from 16-QAM
through 256-QAM. 'A' suffixes indicate DVB compliant FEC
and the 'B' suffixes indicate DigiCipher II FEC encoding.
Note that when using the MEQ1000 in the multiplex mode,
the output QAM mode usually must be 256-QAM. For CATV
systems using DigiCipher II, select the QAM-256B mode.
For DISH Network QAM distribution or other DVB systems
using DVB set tops, choose the QAM-256A mode.
When used for a single input processing function, choose
the output mode accordingly from any of the available
options that will provide a high enough data rate.
GRAY ENCODING: This menu is only available when QAM
modes QAM-16A through QAM-1024A, are selected. The
choices are DVB and DAVIC. Gray Encoding is normally not
used for video data.
QAM SYMRATE: Preset or Manual: If PRESET is
selected, the symbol rate will be automatically set to the
‘normal’ rate based on the QAM mode that is selected and
assuming a 6 MHz wide QAM channel. If MANUAL is
selected, pressing the right or left arrow buttons will allow
selection of symrates from 1.000 thru 7.000 MSym/Sec
using the up and down arrow buttons.
QAM SYMRATE: This menu allows selection of the output
QAM baudrate or symbol rate. Set as required by the set
top box. When multiplexing two ATSC input signals, in
DigiCipher II, 256-QAM CATV systems, this is usually
5.3606 Ms/s. In DVB systems, the rate would be 5.264
Ms/s. In any case, the rate must be high enough to provide
a data bitrate of at least 38.81 Mbps (do not confuse this
with the symbol rate). If the set top box requires a fixed
higher rate, this may be manually set.
12 Setup and Programming, continued / Operation
INTERLEAVER: Sets the QAM modulator interleaver. Choose
among the available selections based upon your system / set top
box requirements. For typical 256-QAM. DigiCipher II CATV
systems, I128, J1 is the most commonly used interleave setting but
many other choices are available. This menu does not appear in
the adjust mode if the QAM mode is A (DVB) as there is only one
choice in the DVB standard. When not in adjust mode, this screen
will display the setting in QAM - A modes as well.
OUTPUT FORMAT: For normal operation, select NORMAL. For
system level set up, choose CW to provide a CW carrier at the
center frequency of the output channel for use in leveling a system
when a QAM power meter is not available. To disable all RF output,
select STANDBY. In the CW mode, the CW carrier can be
measured on a spectrum analyzer without a need to apply a
bandwidth correction or it can be measured with an analog meter
tuned to channel center. The CW power measured will equal the
channel QAM power when the modulator is returned to NORMAL
output mode. Usually QAM signals are set 5 dB to 10 dB
below analog NTSC channels when balancing a system. The
PRBS modes provide a pseudo random binary sequence output
test signal for use in laboratory testing.
OUTPUT CHANMAP, OUTPUT CHANNEL: Select the desired EIA
CATV channel output using these two menus.
RF OUT: Select the desired RF output signal level. The available
range is between 45 dBmV and 62 dBmV, selectable in 0.5 dB
steps. The output accuracy is ± 1 dB.
SETUP: SDE24
SELECT: The LEFT and RIGHT buttons allow the user to scroll
through the encoder numbers for each encoder installed in the
MEQ1000 as well as the MEQ1000 itself. Use the LEFT and RIGHT
buttons to select the encoder to be programmed.
OPERATION - MULTIPLEXING TWO ATSC INPUTS
To use the DTD1000, SDE24 and/or the ASII modules to multiplex
two ATSC inputs, proceed as follows:
1) Connect the off-air antenna, CATV feed, or audio and video
(SDE24) or ASI feed, to the INPUT A and INPUT B inputs of the
MEQ1000. If using two RF inputs the two input connectors are
available in case the two RF signals must come from different
antennas or if one signal is coming from a cable system, etc. If
using a common antenna, use a good quality two way splitter to
split the antenna and feed each input.
2) Plug the power cord from the unit into the power source.
3) Follow the instructions in the programming section above to
set the channel map and channel number for both INPUT
MODULE A and INPUT MODULE B.
4) Set the QAM SYMRATE to PRESET.
5) Set the MULTIPLEX setting ENABLED
6) Set the INPUT B OFFSET to 10. Read details in program-
ming section to determine if you need another value.
7) Select the desired MPEG programs. (See the previous
section for details.)
8) In the PSIP menu, select BASIC MGT VCT for now, this may
be changed later. See programming section for detail.
9) In the VCT TABLE menu, select TVCT.
10) In the MAJOR CHANNEL menu, select OUTPUT CHAN-
NEL. This may be changed later.
11) From the QAM MODE menu, set the QAM modulator to
QAM-256B for use in a DigiCipher II environment. If DVB, use
QAM-256A instead.
12) In the QAM SYMRATE menu, select PRESET.
13) Set the INTERLEAVER to I128,J1 if in a DigiCipher II
environment. There is no interleaver menu when the QAM
mode is set to A (DVB).
14) Set the OUTPUT FORMAT to NORMAL.
15) Set the OUTPUT CHANMAP and OUTPUT CHANNEL to
the desired EIA CATV output channel.
If the second program is being input to a ASII Module via the ASI
input instead of a DTD1000, the same steps apply except that
there will be no parameters to set for the ASII MODULE.
SET TOP BOX MAPPING
When setting up a program map for your set top boxes to include
off-air channels that are multiplexed by the MEQ1000 be sure to
inform the programmer that the MPEG program numbers for the
programs coming in through INPUT MODULE B or ASI B have
been offset by the amount selected in the INPUT B OFFSET
menu. As an example: If input A is providing a channel with
MPEG programs 1 and 2 in the stream and input B is providing a
channel with MPEG programs 1, 2, 3, 4, and 5 in the stream, and
the INPUT B OFFSET is set to 10, then the new output signal will
contain MPEG programs with program numbers of 1, 2, 11, 12,
13, 14, and 15. If the set top is not looking for the right program
number, you will not receive any video!
VIDEO: This menu entry allows the user to select between S-
VIDEO and COMPOSITE video input for each selected encoder.
FORMAT: Either MPEG2 or MPEG4 H.264 may be selected as the
output format for the selected encoder using this menu item.
Encoder 2 on a given SDE24 has no option. It is forced to MPEG2.
RESOLUTION: The resolution of the video output of each encoder
may be selected from this menu item. The choices range from 720
x 480 thru 353 x 240 as shown on the software flow chart on page
9.
BRIGHTNESS, CONTRAST, SATURATION and HUE: These
menu items allow the user to assign each of these parameters of
the output video values from 0 to 255.
MAX AUDIO IN: This menu entry allows the user to set the
maximum audio input which may be input to the selected encoder.
The choices are 1 Vrms or 2 V rms.
AUDIO GAIN: The audio output level can be chosen from this
menu item by selection of the appropriate gain. The values range
from + 15 dB to - 15 dB. Audio output can also be completely
eliminated using the ‘MUTE’ selection.
AUDIO ENCODER: The SDE24 includes audio encoders for Dolby
Digital Stereo commercial encoding (AC3) or MPEG1 Layer 2 audio
encoding (MP2). In the USA, the majority of applications will use
AC3 but if your network is using Annex A (DVB) set top boxes, they
may require the MPEG audio selection. Some TVs and set top
boxes will decode either mode but be sure to set the encoder to the
mode used by other programming on your system to insure
complete compatibility. The AUDIO ENCODE(R) menu allows you
to select either AC3 or MP2. Use the up/dn arrow keys to toggle
between the two settings.
Operating Instructions (From Drake 13
Digital Headend Control Program)
Operating Instructions - From Drake Digital Headend
Control Program
1) Confirm that all connections to the MEQ1000 and its
installed encoder modules have been made as described
previously. Connect a serial cable from the RS232 IN
connector on the MEQ1000 to the serial port on the PC. (This
discussion assumes that the Headend Control Program has
already been installed on the PC as per the instructions
supplied with the software.)
2) Activate the software. You
should see a screen similar to
FIGURE 1 at right.
3) Click on the ‘Setup New
Headend’ button. This will
bring up the screen shown in
FIGURE 2. Type in the name
of the headend in the
‘HeadEnd Name’ field. In this
case we have typed in
MEQ1000. Then select the
‘PC Baudrate’ and ‘Using
Port’. If you intend to use a
modem instead of a direct
connection, make that
selection using the ‘Connect
via:’ radio buttons, and type in
the phone number of the
desired modem in the ‘Number
to dial’ window. Then click
‘OK’.
4) You will be presented with
a screen similar to the one
shown on FIGURE 3. Click on
FIGURE 1
FIGURE 2
Select MEQ1000 Unit ID MEQ1000 Tab
View/Edit Button FIGURE 3
This will bring up the screen shown in FIGURE 4. Click on
the Transcoder box and select the transcoder number you
wish to program. In this case we have selected Transcoder
1. Then select 'Input A' and select the number of the encoder
you choose to
program. In this
case, 'Input A'
contains an SDE24
which contains two
encoders. Select
radio button '1' and
program each
parameter to the
desired value.
Select radio button
2 and set each
FIGURE 4
FIGURE 5
7) This screen allows
the user to reasign
MPEG numbers as
well as new major and
minor channel
numbers.
8) Once the selec-
tions have been
made, click on the
‘Download to
MEQ1000’ button.
This will transfer all
selections on this
screen as well as all
selections made on
the previous screens
to the MEQ1000 and
its installed modules.
the MEQ1000 tab, and click on the box representing the
MEQ1000 unit ID of the unit you are programming. In this
example we selected Unit ID #1. Then click on the ‘View Edit’
button.
parameter to the desired value. Select in turn, 'Input B', 'Mux
Setup' and 'Output' and set each parameter as described
previously. Note that if the value of the parameter selected in
the left column differs from the value of that parameter in the
right column, that value will appear in red.
6) Click on the ‘Set Major/Minor Channel Numbers’ button.
You will be presented with a screen shown in FIGURE 5.
Close this screen by clicking on the ‘X’ in the upper right
hand corner of the screen.
9) You will note that all of the items in the right hand columns
in the 'Input A', 'Input B', 'Mux Setup' and 'Output Encoders',
screens are now black and agree with the selections made in
the left hand columns.
10) Additional information on the operation of the Drake
Digital Headend Control Program can be found in the
instructions included on the program CD.
14 Additional Information
ADDITIONAL INFORMATION
STANDBY MODE
The MEQ1000 has a standby output mode which turns off
the RF output. This can be used when it is desirable to
temporarily disable the output without unplugging the AC
line cord. Select STANDBY in the OUTPUT FORMAT
menu.
OVER TEMPERATURE SENSOR
Temperature monitoring is built into these products. If the
ventilation slots or fan output opening are blocked or the
fan should stop, overheating can occur. If this condition is
detected, the default LCD message will change to OVER
TEMP. If this occurs, the problem should be corrected as
soon as possible. The unit will remain operational but the
ventilation must be restored to prevent premature part
failures due to overheating.
STATUS DISPLAYS
When the units are not in the adjust/program mode, status
displays are shown. These vary by input module: DTD1000
- shows DEMOD SNRs. ASII module shows ASI data
presence.
Pushing the UP arrow button will cause the firmware
version number to display. Pressing the DOWN arrow will
cause the percentage of buffer capacity that is currently in
use on the left side of the display and the maximum
percentage of buffer capacity that has occurred since the
unit was last programmed on the right side, for the QAM
output selected.
REMOTE CONTROL AND MONITORING
The MEQ1000 may be used with the 'Drake Digital
Headend Remote Control Software' program to allow
remote monitoring or control. Only version 2.10.0 or newer
is compatible with the MEQ1000. If an SDE24 module is
installed the Drake Digital Headend Remote Control
Software version must be version 3.1.2 or above.
Connect the RS232 cable coming from the PC or modem
to the RS232 IN DB9 rear panel connector.
Assign a UNIT ID (1 to 63) to use the remote program.
Leave at, or set to, 0 if no remote access is desired.
Set the RS232 BAUD RATE to match the PC setting.
If you are familiar with the program, operation will be clear.
If not familiar with it, see further instructions in the insert
provided with the CDROM or stored on the CDROM.
The MEQ1000 may also be used with the SCTeci to
provide webpage control over a network using an Ethernet
connection to the SCTeci. For control of the MEQ1000, the
SCTeci must have version 5.0 or newer firmware.
EIA/NCTA
Numeric
Equivalent
86
87
88
89
90
91
92
93
94
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
Frequency
in MHz
597
603
609
615
621
627
633
639
645
651
657
663
669
675
681
687
693
699
705
711
717
723
729
735
741
747
753
759
765
771
777
783
789
795
801
807
813
819
825
831
837
843
849
855
861
CATV Channel Frequencies 15
TABLE 1: CATV
Channel
Number
CABLE TV CHANNELS
Center of
Channel
EIA/NCTA
Numeric
Equivalent
2
3
4
5
6
95
96
97
98
99
14
15
16
17
18
19
20
21
22
7
8
9
10
11
12
13
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
Frequency
in MHz
57
63
69
79
85
93
99
105
111
117
123
129
135
141
147
153
159
165
171
177
183
189
195
201
207
213
219
225
231
237
243
249
255
261
267
273
279
285
291
297
303
309
315
321
Channel
Number
CABLE TV CHANNELS
Center of
Channel
Channel
Number
CABLE TV CHANNELS
Center of
Channel
EIA/NCTA
Numeric
Equivalent
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
Frequency
in MHz
327
333
339
345
351
357
363
369
375
381
387
393
399
405
411
417
423
429
435
441
447
453
459
465
471
477
483
489
495
501
507
513
519
525
531
537
543
549
555
561
567
573
579
585
591
Channel
Number
CABLE TV CHANNELS
Center of
Channel
EIA/NCTA
Numeric
Equivalent
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
Frequency
in MHz
867
873
879
885
891
897
903
909
915
921
927
933
939
945
951
957
963
969
975
981
987
993
999
16 Broadcast TV Channel Frequencies
TABLE 2: BC TV
Center of Channel
Frequency (MHz)
57
63
69
79
85
177
183
189
195
201
207
213
2
3
4
5
6
7
8
9
10
11
12
13
VHF BROADCAST CHANNELS
Channel
Number
473
479
485
491
497
503
509
515
521
527
533
539
545
551
557
563
569
575
581
587
593
599
605
611
617
623
629
635
641
647
653
659
665
671
677
683
689
695
701
707
713
719
725
731
737
743
749
755
761
767
773
779
785
791
797
803
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
Center of Channel
Frequency (MHz)
UHF BROADCAST CHANNELS
Channel
Number
Service / If You Need To Call For Help 17
SERVICE INFORMATION
You may contact the R.L. DRAKE Service Department for
additional information or assistance by calling
+1 (937) 746-6990, Monday through Friday, between
8:00 A.M. and 4:00 P.M. Eastern Time, except on holidays.
You may also contact the R.L. DRAKE Service Department by
E-mail at the following address:
or by Telefax:
+1 (937) 806-1576.
Should you want to return your unit for service, package
the unit carefully using the original carton or other suitable
container.
Write your return address clearly on the shipping carton
and on an enclosed cover letter describing the service
required, symptoms or problems. Also include your
daytime telephone number and a copy of your proof of
purchase.
The unit will be serviced under the terms of the
R.L. DRAKE LLC Limited Warranty and returned
to you.
Red is an overnight service. Send the unit in a way that it
can be traced if we can’t verify receipt of shipment. We
suggest UPS or insured postal shipment.
If the unit is still under the original owners warranty,
R.L. DRAKE will pay the cost of the return shipment to
you. Our return shipping policy is that we will return it UPS
Brown if received Brown or by US Mail, it will be returned
Blue if received Blue or Red—or it will be returned
however you prefer if you furnish the return cost for the
method you select.
If the unit is out of warranty, use one of the following
methods for return shipment:
1) You designate billing to American Express, VISA,
MasterCard or Discover card;
2) You prepay the service charges with a personal check,
or
3) You specify some other method of return and payment.
When calling, the technician can estimate the repair
charges for you over the phone. This is another good
reason to call before sending a unit in for repair.
Typically, equipment is repaired in five to ten working days
after it arrives at R.L. DRAKE if we have all the facts. If we
must call you, it may take longer. R.L. DRAKE is not
responsible for damage caused by lightning, nonprofes-
sional alterations, “acts of God, shipping damage, poor
storage/handling, etc. R.L. DRAKE will make note of any
shipping damage upon receipt.
You will need to send proof of purchase to receive
warranty service. Typically, a copy of the invoice from an
R.L. DRAKE dealer will suffice. The warranty is for the
original owner only and is not transferable.
IF YOU NEED TO CALL FOR HELP
Call our Customer Service/Technical Support line at
+1 (937) 746-6990 between 8:00 A.M. and 4:00 P.M.
Eastern Time, weekdays. Please have the unit’s serial
number available. We will also need to know the specifics
of any other equipment connected to the unit.
When calling, please have the unit up and running, near
the phone if possible. Our technician(s) will likely ask
certain questions to aid in diagnosis of the problem. Also,
have a voltmeter handy, if possible.
R.L. DRAKE also provides technical assistance by
or by Telefax: +1 (937) 806-1576.
Many of the products that are sent to us for repair are in
perfect working order when we receive them. For these
units, there is a standard checkout fee that you will be
charged. Please perform whatever steps are applicable
from the installation sections of the Owner's Manual
before calling or writing—this could save unnecessary
phone charges. Please do not return the unit without
contacting R.L. DRAKE first: it is preferred to help
troubleshoot the problem over the phone (or by mail) first,
saving you both time and money.
Inside the carton, enclose a note with your name, ad-
dress, daytime phone number, and a description of the
unit’s problem.
The unit must be sent to the following address:
Service Department
R.L. DRAKE LLC
230 Industrial Drive
Franklin, Ohio 45005 U.S.A.
Be sure to include your street address which will be
needed for UPS return. UPS Surface (Brown Label) takes
7-10 days to reach us depending on your location, Blue
takes 2-3 days.
18 Warranty
Three Year Limited Warranty
R.L. DRAKE LLC warrants to the original purchaser this product shall be free from defects in material or workmanship
for three (3) years from the date of original purchase.
During the warranty period the R.L. DRAKE LLC or an authorized Drake service facility will provide, free of charge,
both parts and labor necessary to correct defects in material and workmanship. At its option,
R.L. DRAKE LLC may replace a defective unit.
To obtain such a warranty service, the original purchaser must:
(1) Retain invoice or original proof of purchase to establish the start of the warranty period.
(2) Notify the R.L. DRAKE LLC or the nearest authorized service facility, as soon as possible after discovery of a
possible defect, of:
(a) the model and serial number,
(b) the identity of the seller and the approximate date of purchase; and
(c) A detailed description of the problem, including details on the electrical connection to associated equipment and
the list of such equipment.
(3) Deliver the product to the R.L. DRAKE LLC or the nearest authorized service facility, or ship the same in its original
container or equivalent, fully insured and shipping charges prepaid.
Correct maintenance, repair, and use are important to obtain proper performance from this product. Therefore
carefully read the Instruction Manual. This warranty does not apply to any defect that R.L. DRAKE LLC determines
is due to:
(1) Improper maintenance or repair, including the installation of parts or accessories that do not conform to the quality
and specifications of the original parts.
(2) Misuse, abuse, neglect or improper installation.
(3) Accidental or intentional damage.
All implied warranties, if any, including warranties of merchantability and fitness for a particular purpose, terminate
three (3) years from the date of the original purchase.
The foregoing constitutes R.L. DRAKE LLC’S entire obligation with respect to this product, and the original purchaser
shall have no other remedy and no claim for incidental or consequential damages, losses or expenses. Some states
do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitation of incidental
or consequential damages, so the above limitation and exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
This warranty shall be construed under the laws of Ohio.
For Service, contact:
R.L. DRAKE LLC
230 Industrial Drive
Franklin, Ohio 45005 U.S.A.
Customer Service and Parts Telephone: +1 (937) 746-6990
Telefax: +1 (937) 806-1576
World Wide Web Site: http://www.rldrake.com
R.L. Drake LLC
230 Industrial Drive
Franklin, Ohio 45005 U.S.A.
Customer Service and Parts Telephone: +1 (937) 746-6990
Telefax: +1 (937) 806-1576
World Wide Web Site: http://www.rldrake.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19

DRAKE DQT1000 Manuel utilisateur

Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues