Wacker Neuson PS32200 Manuel utilisateur

Taper
Manuel utilisateur

Ce manuel convient également à

www.wackergroup.com
Pump
PS 3 1500
PS 3 2200
OPERATOR’S MANUAL
0154622en 002
0603
0154622EN
PS 3 1500/ PS 3 2200 Table of Contents
wc_bo0154622002enTOC.fm 1
1. Foreword 3
2. Safety Information 4
2.1 Operating and Electrical Safety ............................................................ 5
2.2 Information Labels ................................................................................ 5
3. Technical Data 6
3.1 Standard Specifications ........................................................................ 6
3.2 Operating Specifications (60 Hz) .......................................................... 7
4. Operation 8
4.1 Names of Parts ..................................................................................... 8
4.2 Prior to Operation ................................................................................. 9
4.3 Installation ............................................................................................ 9
4.4 Electrical Wiring .................................................................................. 12
4.5 Electrical Circuit Diagrams ................................................................. 14
4.6 Operation ............................................................................................ 16
5. Maintenance 19
5.1 Periodic Maintenance Schedule ......................................................... 19
5.2 Maintenance and Inspection .............................................................. 20
5.3 Disassembly and Reassembly ........................................................... 22
5.4 Disassembly ....................................................................................... 23
5.5 Reassembly Procedure ...................................................................... 23
5.6 Troubleshooting .................................................................................. 25
Table of Contents PS 3 1500/ PS 3 2200
wc_bo0154622002enTOC.fm 2
Foreword
wc_tx000001gb electric.fm 3
1. Foreword
This manual provides information and procedures to safely operate
and maintain this Wacker model. For your own safety and protection
from injury, carefully read, understand and observe the safety
instructions described in this manual.
Keep this manual or a copy of it with the machine. If you lose this
manual or need an additional copy, please contact Wacker
Corporation. This machine is built with user safety in mind; however,
it can present hazards if improperly operated and serviced. Follow
operating instructions carefully! If you have questions about operating
or servicing this equipment, please contact Wacker Corporation.
The information contained in this manual was based on machines in
production at the time of publication. Wacker Corporation reserves the
right to change any portion of this information without notice.
All rights, especially copying and distribution rights, are reserved.
Copyright 2003 by Wacker Corporation.
No part of this publication may be reproduced in any form or by any
means, electronic or mechanical, including photocopying, without
express written permission from Wacker Corporation.
Any type of reproduction or distribution not authorized by Wacker
Corporation represents an infringement of valid copyrights and will be
prosecuted. We expressly reserve the right to make technical
modifications, even without due notice, which aim at improving our
machines or their safety standards.
Safety Information PS 3 1500 / PS 3 2200
wc_si000036gb.fm 4
2. Safety Information
This manual contains DANGER, WARNING, CAUTION, and NOTE
callouts which must be followed to reduce the possibility of personal
injury, damage to the equipment, or improper service.
This is the safety alert symbol. It is used to alert you to potential
personal injury hazards. Obey all safety messages that follow this
symbol to avoid possible injury or death.
DANGER indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury.
CAUTION: Used without the safety alert symbol, CAUTION indicates
a potentially hazardous situation which, if not avoided, may result in
property damage.
Note:
Contains additional information important to a procedure.
DANGER
WARNING
CAUTION
PS 3 1500 / PS 3 2200 Safety Information
wc_si000036gb.fm 5
2.1 Operating and Electrical Safety
To reduce risk of electric shock, connect only to a properly grounded,
grounding-type receptacle.
Risk of electric shock - This pump has not been investigated for use in
swimming pool areas.
An acceptable motor-control switch shall be provided at the time of
installation according to local codes and regulations.
To reduce risk of electric shock, see instruction manual for proper
installation.
CAUTION: This pump may automatically restart. Prior to working on
the pump or control panel all supply circuits must be disconnected.
CAUTION: Risk of shock - Do not remove cord and strain relief.
2.2 Information Labels
Label Meaning
A nameplate listing the Model Number, Item
Number, Revision, and Serial Number is
attached to each unit. Please record the informa-
tion found on this plate so it will be available
should the nameplate become lost or damaged.
When ordering parts or requesting service infor-
mation, you will always be asked to specify the
model, item number, revision number, and serial
number of the unit.
WARNING
Technical Data PS 3 1500 / PS 3 2200
wc_td000036gb.fm 6
3. Technical Data
3.1 Standard Specifications
Applicable Liquids,
Consistency and
Temperature
Rain Water, Fountain Water, Ground Water,
Sand-Carrying Water
0–40°C (32–104°F)
Pump Impeller Semi-Vortex Type
Shaft Seal Double Mechanical Seal
Bearing Shielded Ball Bearing
Motor Specification Dry Submersible Induction Motor (2-Pole)
Insulation Class B
Protection System Circle Thermal Protector
Lubricant SAE 10W/20W
Such as:
–Turbine Oil ISO VG #32
–Shell Victrolia Oil #27
–British Pet Energol THB #32
–Gulf Paramount #32
–Tellus #T22 Shell Oil
–Shell Turbo T32
Connection Coupling (NPT 3”)
PS 3 1500 / PS 3 2200 Technical Data
wc_td000036gb.fm 7
3.2 Operating Specifications (60 Hz)
*The weight (mass) given above is the operating weight of the pump itself, not including the cable
assembly.
Part No.
PS 3 1500 PS 3 2200
0009119
0009117 0009118
Pump
Bore
mm (in.)
80 (3)
Phase 1
Starting Method Capacitor-Run Capacitor-Start
Capacitor-Run
Output
kW (Hp)
1.5 (2) 2.2 (2)
Rated Current
A
(V)
23.0
110
11.5
220
13.0
220
Maximum Head
m (ft.)
21 (69) 26 (85)
Maximum Capacity
L/min
(GPM)
420
(111)
493
(130)
Maximum Pressure
kg/cm
2
(psi)
2.1
(30)
2.6
(37)
Solid Size Capacity
mm (in.)
8.5 (0.3)
Weight*
Kg (lbs.)
28.8 (63.5) 29.0 (64)
Operation PS 3 1500 / PS 2 2200
wc_tx000115gb.fm 8
4. Operation
4.1 Names of Parts
See Graphic: wc_gr000321
Ref. Description Ref. Description
1. Coupling 9. Dust Seal
2. Mechanical Seal 10. Wear Ring
3. Gasket 11. Oil Housing
4. Sleeve 12. Impeller
5. Cable Assembly 13. Volute
6. Lifting Handle 14. Strainer
7. Lubricant 15. Retainer Plate
8. Oil Plug
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
wc_gr000321
PS 3 1500 / PS 2 2200 Operation
wc_tx000115gb.fm 9
4.2 Prior to Operation
When the pump is delivered, first perform the following checks:
Inspection
While unpacking, inspect the product for damage during shipment, and
make sure all bolts and nuts are tightened properly.
Specification check
Check the model number to make sure it is the product that was
ordered. Be certain it is the correct voltage and frequency.
Note:
If there is any problem with the product as shipped, contact your
nearest dealer or Wacker representative at once.
Product specifications
Do not operate this product under any conditions other than those for
which it is specified. Failure to observe this precaution can lead to
electrical shock, current leakage, fire, water leakage or other
problems.
4.3 Installation
If the pump is used to drain a swimming pool, the pump must be
connected to a Ground Fault Interrupter (GFI).
If the pump is used in fountains, the pump must be connected to a
Ground Fault Interrupter (GFI).
The pump must not be used when people are in the water.
Leakage of pump lubricants may cause pollution of water.
Proper plug must be provided according to local codes and standards.
Refer to wiring diagram.
DO NOT use this pump in liquids other than water, such as oil, salt
water, or organic solvents.
Use with a power supply voltage within ±5% of the rated voltage.
DO NOT use in water temperatures outside the range of 32–104°F (0–
40°C) which can lead to failure, current leakage or shock.
DO NOT use in the vicinity of explosive or flammable materials.
Use only in fully assembled state.
Note:
Consult your local dealer or Wacker representative before using
with any liquids other than those indicated in this document.
Maximum Allowable Water Pressure
CAUTION
WARNING
Operation PS 3 1500 / PS 2 2200
wc_tx000115gb.fm 10
CAUTION: Do not use at greater than the water pressure shown,
which can damage the pump resulting in electrical leakage and
electrical shock.
Preparing for Installation
Before installing the pump at a work site, you will need to have the
following tools and instruments ready:
Insulation resistance tester (megohmmeter)
AC voltmeter
AC ammeter (clamp-on type)
Bolt and nut tighteners
Power supply connection tools (screwdriver or box wrench)
Note:
Please also read the instructions that come with each of the test
instruments.
Checks to Make Before Installation
With the megohmmeter, measure the insulation resistance between
each of the power wires and grounding wire to verify the insulation
resistance of the motor.
Reference insulation resistance: 20MW or greater
Note:
The reference insulation resistance (20M
W
or greater) is the
value when the pump is new or has been repaired. For the reference
value after installation, see Maintenance and Inspection.
Precautions in Installation
When installing the pump, pay close attention to its center of gravity
and weight. If it is not lowered into place correctly, it may fall and be
damaged or cause injury.
When transporting the pump by hand, be sure to employ manpower
commensurate with the weight of the pump. To avoid back injury when
lifting the pump, bend the knees to pick it up rather than bending your
back only.
Do not under any circumstances install or move the pump by
suspending it from the cable assembly. The cable may be damaged,
causing electrical leakage, shock, or fire.
Model Maximum Allowable Water Pressure
PS 3 1500/2200 0.3 MPa (43 PSI)
WARNING
CAUTION
PS 3 1500 / PS 2 2200 Operation
wc_tx000115gb.fm 11
4.3.1 The pump is supplied with a threaded discharge fitting. Tighten hose
coupling or discharge pipe securely and with proper gaskets.
4.3.2 Avoid dropping the pump or other strong impact. Lift the pump by
holding it firmly with the hands or by attaching a rope or chain to the
lifting handle.
Note:
On cable assembly handling, see Electrical Wiring.
4.3.3 Install the pump in a location with sufficient water level, where water
collects readily.
Note:
See Operation (“Operating Water Level”) for the water level
necessary for operation. The discharge end of the hose should be
located higher than the water surface. If the end of the hose is
submerged, water may flow back to the pump when the pump is
stopped; and if the hose end is lower than the water surface, water may
overflow when the pump is turned off.
4.3.4 The hose should be run as straight as possible, since excessive
bending will hinder the water flow, preventing sufficient lift, and can
even cause the hose to become clogged with earth. If the hose is
crimped near the pump, air can become trapped in the pump and
cause idle running.
If large quantities of earth are sucked up, damage resulting from
friction in the pump can lead to electrical leakage and shock.
CAUTION: When the pump is installed at a work site, make sure the
hose is connected in such a way as to ensure proper drainage.
Otherwise water may leak out and cause damage to surrounding walls
or flooring, or to equipment.
4.3.5 Use the pump in the upright position. To prevent the strainer from
becoming submerged in mud, causing it to suck in sand or debris,
mount it on a block or other firm base.
4.3.6 If used in a permanent installation, where the pump is not readily
accessible after installation, please contact Wacker for a duplicate
nameplate to be installed at the wellhead or on the control box so that
it will be readily visible.
4.3.7 Do not operate the pump dry. Doing so will prevent the pump from
attaining its full potential and may also damage the pump and lead to
a short and electrical shock.
CAUTION
CAUTION
Operation PS 3 1500 / PS 2 2200
wc_tx000115gb.fm 12
4.4 Electrical Wiring
Performing electrical wiring
Electrical wiring should be performed by a qualified person in accord
with all applicable regulations. Failure to observe this precaution not
only risks breaking the law but is extremely dangerous.
Incorrect wiring can lead to current leakage, electrical shock or fire.
ALWAYS make sure the pump is equipped with the specified overload
protectors and fuses or breakers, so as to prevent electrical shock from
a current leak or pump malfunction.
Operate within the capacity of the power supply and wiring.
Grounding
DO NOT use the pump without first grounding it properly. Failure to
ground it can lead to electrical shock from a current leak or pump
malfunction.
DO NOT attach the grounding wire to a gas pipe, water pipe, lightning
arrestor or telephone grounding wire. Improper grounding can result in
electrical shock.
Connecting the power supply
Before connecting leads to the terminal strip, make certain the power
supply is turned off (circuit breaker, etc.), to avoid electrical shock,
shorting, or unexpected starting of the pump, leading to injury.
Do not use the pump if the cable assembly is worn or damaged, which
can result in electric shock, shorting, or fire.
Connect the leads to the control panel terminals as shown in the
diagram, making sure they do not become twisted together.
See Graphic: wc_gr000260
WARNING
WARNING
CAUTION
WARNING
CAUTION
R
W
G
wc_gr000260
PS 3 1500 / PS 2 2200 Operation
wc_tx000115gb.fm 13
Cable Assembly
If it is necessary to extend the cable assembly, use a core size equal
to or larger than the original. This is necessary not only for avoiding a
performance drop, but to prevent cable overheating which can result in
fire, electrical leakage or electrical shock.
If a cable with cut insulation or other damage is submerged in the
water, there is a danger of damage to the pump, electrical leakage,
electrical shock, or fire.
Be careful not to let the cable assembly be cut or become twisted. This
may result in damage to the pump, electrical leakage, electrical shock,
or fire.
If it is necessary to submerge the connection wires of the cable
assembly in water, first seal the wires completely in a molded
protective sleeve, to prevent electrical leakage, electrical shock, or fire.
DO NOT allow the cable assembly wires or power supply plug to
become wet.
Make sure the cable does not become excessively bent or twisted, and
does not rub against a structure in a way that might damage it.
If used in a deep-well installation, the cable assembly should be
secured every twenty feet.
CAUTION
Operation PS 3 1500 / PS 2 2200
wc_tx000115gb.fm 14
4.5 Electrical Circuit Diagrams
See Graphic: wc_gr000322 and wc_gr000323
PS 3 1500 CAPACITOR-START MODELS, SINGLE PHASE MOTOR
Ref. Description Ref. Description
A Protector E Main Coil
B Heater F Aux. Coil
C Bi-metal G Centrifugal Switch
D To Power Supply H Capacitor
Wire Colors
B Black R Red Y Yellow Or Orange
G Green T Tan Br Brown Pr Purple
L Blue V Violet Cl Clear Sh Shield
P Pink W White Gr Gray LL Light Blue
A
B
E
H
C
2
3
1
F
G
D
wc_gr000322
wc_gr000322
PS 3 1500 / PS 2 2200 Operation
wc_tx000115gb.fm 15
PS 3 2200 CAPACITOR-START AND -RUN MODELS, SINGLE PHASE MOTOR
If connected to a circuit protected by a fuse, use a time-delay fuse with
this pump.
Ref. Description Ref. Description
A Protector E Main Coil
B Heater F Aux. Coil
C Bi-metal G Centrifugal Switch
D To Power Supply H Starting Capacitor
J Running Capactor
Wire Colors
B Black R Red Y Yellow Or Orange
G Green T Tan Br Brown Pr Purple
L Blue V Violet Cl Clear Sh Shield
P Pink W White Gr Gray LL Light Blue
A
B
E
H
C
2
3
1
F
G
D
wc_gr000323
wc_gr000323
J
CAUTION
Operation PS 3 1500 / PS 2 2200
wc_tx000115gb.fm 16
4.6 Operation
Before starting
4.6.1 Make sure once again that the product is of the correct voltage and
frequency rating.
CAUTION: Using the product at other than rated voltage and
frequency will not only lower its performance but may damage the
product.
Note:
Confirm the rated voltage and frequency on the model
nameplate.
4.6.2 Confirm the wiring, supply voltage, circuit breaker capacity, and motor
insulation resistance.
Reference insulation resistance = 20 M or greater.
Note:
The reference insulation resistance (20 M
or greater) is the
value when the pump is new or has been repaired. For the reference
value after installation see Maintenance and Inspection.
4.6.3 The setting on the circuit breaker or other overload protector should be
made in accord with the rated current of the pump.
Note:
See Standard Specifications for the rated current of the pump.
4.6.4 When powering the pump with a generator, be certain the generator is
sized to supply the required power for the pump and any other
equipment powered by the generator.
Test Operation
NEVER operate the pump while it is suspended in the air. The recoil
may result in injury or other major accident.
NEVER start the pump when people are standing next to it. A current
leak can result in electrical shock.
Run the pump for a short time (3–10 minutes) and confirm the
following:
Using an ammeter (clamp-on type), measure the operating cur-
rent at the L1 and L2 phase wires on the terminal.
COUNTERMEASURE: If the operating current exceeds the rated
value, pump motor overload may be a cause. Make sure the pump has
been installed under proper conditions as described in
Installation
.
Using an AC voltmeter (tester), measure voltage at the terminals.
Supply voltage tolerance: within ±5% of rated voltage.
WARNING
WARNING
PS 3 1500 / PS 2 2200 Operation
wc_tx000115gb.fm 17
COUNTERMEASURE: If the supply voltage is outside the tolerance,
possible causes are the power supply capacity or an inadequate
extension cable. Look again at
Electrical Wiring
and make sure the
conditions are proper.
In case of very excessive vibration, unusual noise or odor, turn off the
power immediately and consult with your nearest dealer or Wacker
representative. Continuing to operate the pump under abnormal
conditions may result in electrical shock, fire, or current leakage.
Operation
Make sure no extraneous objects such as pins, nails or other metal
objects are sucked into the pump. These can damage the pump or
cause it to malfunction, and can result in electrical shock or electrical
leakage.
When the pump is not used for an extended period, be sure to turn off
the power (circuit breaker, etc.). Deterioration of the insulation may
lead to electrical leakage, electrical shock, or fire.
In case of a power outage, turn off the power to the pump to avoid
having it start unexpectedly when the power is restored, presenting
serious danger to people in the vicinity.
The pump may become hot during operation. Do not touch an
operating pump. Allow the pump to cool before handling.
Pay careful attention to the water level while the pump is operating. Dry
operation may cause the pump to malfunction.
Note:
See section Operating water level, for the water level necessary
for operation.
If the protection system operates due to an overload or malfunction,
causing the pump to stop, first investigate and remove the cause
before restarting.
CAUTION
WARNING
CAUTION
Operation PS 3 1500 / PS 2 2200
wc_tx000115gb.fm 18
Operating water level
Do not operate the pump below the C.W.L. (Continuous running Water
Level) indicated below. Failure to observe this condition may result in
damage to the pump, current leakage or electrical shock.
See Graphic: wc_gr000324
Operating Water Level
Motor Protection System
(Circle thermal protector)
The pump has a built-in motor protection system (circle thermal
protector). If an excessive current is detected or the motor overheats,
for reasons such as the following, the pump will automatically stop
operating regardless of the water level, to protect the motor:
Change in supply voltage polarity
Overload
Open-phase operation or operation under constraint
Note:
Always determine the cause of the problem and resolve it before
resuming operation. Simply repeating cycles of stopping and restarting
will end up damaging the pump. Do not continue operation at very low
lift, low water level, or while the strainer stand is clogged with debris.
Not only will performance suffer, but also such conditions may cause
noise, heavy vibration, and malfunctioning.
Pump Model C.W.L.
PS 3 1500 80 mm (3-1/8")
PS 3 2200 80 mm (3-1/8")
CAUTION
CWL
wc_gr000324
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56

Wacker Neuson PS32200 Manuel utilisateur

Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues