W415-1739 / C / 08.03.17
EN
16
finish framing - after appliance installation
7.0 rough framing - before appliance installation
single-sided
see-thru
Before framing your appliance, determine vent requirements before deciding the final location of the appliance.
After rough framing, place the appliance in its final position. Also, see appliance manual for vent shield installation,
nailing tabs installation,electrical installation, gas installation, etc.
Ref LV38-1 LV50-2 LV62 LV74
E
16 3/16” (41.1cm) 16 3/16” (41.1cm) 16 3/16” (41.1cm) 16 3/16” (41.1cm)
F
53 13/16” (136.7cm) 65 13/16” (167.2cm) 77 13/16” (197.6cm) 89 13/16” (228.1cm)
J
Optional - Appliance does not need to be elevated above floor
L
73” (185.4cm) 73” (185.4cm) 91” (231.1cm) 91” (231.1cm)
Ref LV38-1 LV50-2 LV62 LV74
E
20 1/8” (51.1cm) 20 1/8” (51.1cm) 20 1/8” (51.1cm) 20 1/8” (51.1cm)
F
53 13/16” (136.7cm) 65 13/16” (167.2cm) 77 13/16” (197.6cm) 89 13/16” (228.1cm)
J
Optional - Appliance does not need to be elevated above floor
L
73” (185.4cm) 73” (185.4cm) 91” (231.1cm) 91” (231.1cm)
E
J
F
E
F
J
L
L
Before framing the appliance, ensure to install
the firestop first as it will not fit between the
studs if installed after framing.
Before framing the appliance, ensure to install
the firestop first as it will not fit between the
studs if installed after framing.
Although the minimum enclosure
height for the LV series is 73”,
some venting configurations
that require more vertical rise
will require a larger enclosure to
provide minimum vertical clear-
ance between vent pipes and
combustibles.
note:
Although the minimum enclo-
sure height for the LV series is
73”, some venting configurations
that require more vertical rise will
require a larger enclosure to pro-
vide minimum vertical clearance
between vent pipes and combus-
tibles.
note: