Vulcan VHP848 Le manuel du propriétaire

Catégorie
Cuisinières
Taper
Le manuel du propriétaire

Ce manuel convient également à

©ITW Food Equipment Group, LLC
3600 North Point Blvd.
Baltimore, MA 21222
RETAIN THIS MANUAL FOR FUTURE USE
FORM F-38334 (09-15)
INSTALLATION & OPERATION MANUAL FOR
GAS HOTPLATES
MODELS
VHP212
VHP424
VHP636
VHP848
AHP212
AHP424
AHP636
AHP848
VHP636
AHP636
For additional information on Vulcan or to locate an authorized parts and
service provider in your area, visit our website at www.vulcanequipment.com
- 2 -
IMPORTANT FOR YOUR SAFETY
THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO
INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD
START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS
MANUAL.
POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN
THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE
OBTAINED FROM THE LOCAL GAS SUPPLIER.
IMPORTANT
IN THE EVENT A GAS ODOR IS DETECTED, SHUT
DOWN UNITS AT MAIN SHUTOFF VALVE AND
CONTACT THE LOCAL GAS COMPANY OR GAS
SUPPLIER FOR SERVICE.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER APPLIANCE.
IN THE EVENT OF A POWER FAILURE, DO NOT
ATTEMPT TO OPERATE THIS DEVICE.
- 3 -
INSTALLATION, OPERATION AND CARE OF
GAS HOTPLATES
GENERAL
Gas Countertop Hotplates are designed for commercial use only and feature fast, efficient
gas heat. Each burner is controlled by an adjustable gas valve. Cast grates and burners
are easily removed for cleaning when cool.
Model
Number Of Burners
BTU/hr Input Rating
Natural Gas
Propane
VHP212/AHP212
2
60,000
55,000
VHP424/AHP424
4
120,000
110,000
VHP636/AHP212
6
180,000
165,000
VHP848/AHP848
8
240,000
220,000
INSTALLATION
UNPACKING
This hotplate was inspected before leaving the factory. The carrier assumes full responsibility for the
safe delivery upon acceptance of the shipment. Check for possible shipping damage immediately after
receipt.
If the hotplate is found to be damaged, complete the following steps:
1. Carrier must be notified within 5 business days of receipt.
2. Carrier’s local terminal must be notified immediately upon discovery (note time, date, and
who was spoken to), and follow up and confirm with written or electronic communication.
3. All original packing materials must be kept for inspection purposes.
4. The hotplate cannot have been moved, installed, or modified.
5. Notify Vulcan Customer Service immediately at 800-814-2028.
LOCATION
The installation location must be kept free and clear of combustibles. Do not obstruct the
flow of combustion and ventilation air. DO NOT install the hotplate adjacent to fryers.
Sufficient air should be allowed to enter the room to compensate for the amount of air
removed by any ventilating system and for combustion of the gas burners. Do not
obstruct the air flow into and around the hotplate. Position the hotplate in its final
location. Check that there are sufficient clearances to service the hotplate and to make
the required gas supply connection(s). Provide 24" clearance at the front for cleaning,
maintenance, service and proper operation.
- 4 -
MINIMUM CLEARENCES
NON-COMBUSTIBLES
COMBUSTIBLES
SIDES
BACK
SIDES
BACK
STANDARD
0”
0”
13”
6”
STEP-UP
0”
0”
13”
9”
INSTALLATION CODES AND STANDARDS
The hotplate must be installed in accordance with:
In the United States of America:
1. State and local codes.
2. National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). This shall include but
not be limited to: NFPA #54 Section 10.3.5.2 for Venting. Copies may be obtained
from The American Gas Association Accredited Standards Committee Z223, @ 400
N. Capital St. NW, Washington, DC 20001 or the Secretary Standards Council, NFPA,
1 Batterymarch Park Quincy, MA 02169-7471
NOTE: In the Commonwealth of Massachusetts
All gas appliances vented through a ventilation hood or exhaust system equipped with
a damper or with a power means of exhaust shall comply with 248 CMR.
3. NFPA Standard # 96 Vapor Removal from Cooking Equipment, latest edition, available
from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
In Canada:
1. Local codes.
2. CAN/CSA-B149.1 Natural Gas Installation (latest edition)
3. CAN/CSA-B149.2 Propane Installation Code (latest edition), available from the
Canadian Gas Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3
CASTER EQUIPPED APPLIANCES
Hotplates mounted on stands with casters must use a flexible connector (not supplied)
that complies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69
CSA 6.16 and a quick-disconnect device that complies with the Standard for Quick-
Disconnect Devices for use With Gas Fuel, ANSI-Z21.41 CSA 6.9. In addition, adequate
means must be provided to limit movement of the hotplate without depending on the
connector and the quick-disconnect device or its associated piping to limit hotplate
movement. Attach the restraining device at the rear of the hotplate. If disconnection of
the restraint is necessary, turn off the gas supply before disconnection. Reconnect the
restraint prior to turning the gas supply on and return the hotplate to its installation
position.
If the Hotplate is installed on casters and is moved for any reason, it is recommended
that it be re-leveled (see LEVELING).
LEVELING
If the hotplate is equipped with legs or is mounted on the optional stand equipped with
legs, turn the feet at the bottom of the legs in or out to level the hotplate in the final
installed location. If the hotplate is mounted on the optional stand equipped with casters,
position the hotplate on a level floor.
- 5 -
VENTILATION HOOD
The hotplate should be installed under a suitable ventilation hood. For safe operation and
proper ventilation, keep the space between the hotplate and vent hood free from any
obstructions.
GAS CONNECTIONS
Gas supply connections and any pipe joint compound must be resistant to the
action of propane gases.
Purge the supply line to clean out any dust, dirt, or any foreign matter before connecting
the line to the unit.
Codes require that a gas shut-off valve be installed in the gas line ahead of the
appliance. The gas supply line must be at least the equivalent of ¾ iron pipe.
An adequate gas supply is necessary. Undersized or low pressure lines will restrict the
volume of gas required for satisfactory performance. A minimum supply pressure of 7"
W.C. for natural gas and 11" W.C. for propane gas is recommended. With all units
operating simultaneously, the manifold pressure on all units should not show any
appreciable drop.
When testing the gas supply piping system, if test pressures exceed ½ psig (3.45 kPa),
the appliance and its individual shutoff valve must be disconnected from the gas supply
piping system. When test pressures are ½ psig (3.45 kPa) or less, the appliance must be
isolated from the gas supply piping system by closing its individual manual shut-off valve
during any pressure testing of the system.
Prior to lighting, check all joints in the gas supply line for leaks.
Use soap and water solution. Do not use an open flame.
GAS PRESSURE REGULATOR INSTALLATION
Gas regulator pressure is preset at 5 W ater Column (W .C.) for natural gas, and 10 W.C.
for propane gas. Minor adjustments may be required based on site specific gas pressure.
Install the regulator as close to the hotplate on the gas supply line as possible. Make sure
that the arrow on the underside of the regulator is oriented in the direction of gas flow to
the hotplate (Fig. 1) and the regulator is positioned with the vent plug and adjustment
screw upright(Fig. 2).
Fig. 1
Fig. 2
- 6 -
The minimum supply pressure (upstream of the regulator) should be 7-9 W.C. for natural
gas and 11-12 W.C. for propane gas. At no time should the hotplate be connected to
supply pressure greater than ½ psig (3.45 kPa) or 14 W.C.
Prior to lighting, check all joints in the gas supply line for leaks.
Use soap and water solution. Do not use an open flame.
OPERATION
The hotplate and its parts are hot. Use care when operating,
cleaning or servicing the hotplate.
CONTROLS
There is one pilot for every two burners. The hotplate is equipped with standing,
unmonitored pilots. Gas will flow from the pilots as soon as the main gas supply to the
unit is turned on. See pilot lighting procedure below.
Each burner is independently controlled by an infinite heat control valve. Once the pilots
are lit, turning the control knob to the ON position will light each burner. The burners will
be in the full ON position when the control knobs are turned all the way to the left. The
burners will be in the full OFF position when the control knobs are turned all the way to
the right.
LIGHTING INSTRUCTIONS
1. See Fig 5. Turn main gas shut-off valve
and all burner control knobs to the OFF
position and wait 5 minutes to allow
any accumulated gas to escape.
2. Remove grates.
3. Turn main gas shut-off valve ON.
Light the pilots. Adjust the pilot valve
screw(See Fig.6) until the pilot flame
has a slight yellow tip.
4. To light burners, turn individual burner
valves to the ON position.
5. If burners fail to light, turn all valves
and the main gas shut-off to the OFF
position and contact an authorized
service contractor.
PILOTS
Fig. 5
- 7 -
PILOT ADJUSTMENT
Using a flathead screwdriver, turn the slotted hex-head pilot adjustment screw clockwise
to decrease the flame, and counterclockwise to increase the flame. See Fig. 6.
CLEANING
The hotplate and its parts are hot. Use care when operating,
cleaning or servicing the hotplate.
Grates may be immersed in commercial cleaning compound overnight. In the morning,
rinse with hot water to remove any residues of cleaning compound. Thoroughly dry and
apply a cooking oil to prevent rusting.
Burner ports and burner rest should be thoroughly cleaned. Venturi must be free from
grease and lint. When cleaning, do not insert a pick into the burner port holes soap and
water will normally do the job. Heavy spattering or spill-over may require cleaning with a
mild oven cleaner. After cleaning, rinse with clean water and dry with a dry cloth. Be sure
to apply a thin coat of cooking oil for protection after cleaning.
Stainless steel surfaces may be cleaned using damp cloth with mild detergent and water
solution.
Places where fat, grease, or food can accumulate must be cleaned regularly.
PILOT ADJUSTMENT SCREWS
Fig. 6
- 8 -
MAINTENANCE
The hotplate and its parts are hot. Use care when operating,
cleaning or servicing the hotplate.
LUBRICATION
All valves must be checked and lubricated periodically. Check with your service agency
for details.
VENT SYSTEM
At least twice a year the exhaust hood (venting system) should be examined and cleaned.
SERVICE
Contact your local Service Contractor for any repairs or adjustments needed on this
equipment. For a complete listing of Service and Parts depots refer to
www.vulcanequipment.com .
When calling for service, the following information should be available from the appliance
identification plate: Model Number and Serial Number.
- 9 -
TROUBLESHOOTING
Burner does not come on A. Problem with gas valve. (Call for service).
when the control knob is B. Pilot burner not lit.
turned on C. Low gas pressure. (Call for service)
Too much heat A. Burner valves adjusted too high
B. Faulty ventilation
C. Overrated gas pressure
D. Improperly adjusted burner
Uneven heat side to side A. Burner valves improperly adjusted
B. Appliance is not level side to side
C. Improperly adjusted burner
Uneven heat front to back A. Appliance is not level front to back
B. Faulty ventilation
C. Improperly adjusted burner
Pilot burner will not stay lit A. Pilot flame is set too low. Adjust pilot to allow for gas flow.
B.Obstruction in pilot orifice
C. Low gas pressure. (Call for Service).
Yellow burner flames A. Open burner shutters until flames are blue
Lifting burner flames A. Close burner shutters until flames touch burner
Fluctuating gas pressure A. Check for clogged vent on regulator
- 10 -
ACCESSORY INSTALLATION
The hotplate and its parts are hot. Use care when operating,
cleaning or servicing the hotplate.
1
2
- 11 -
3
4
5
- 12 -
NOTES
- 12 -
REMARQUES
- 11 -
3
4
5
- 10 -
INSTALLATION DE COMPLICE
La plaque de cuisson et ses pièces sont chaudes. Faites
attention lorsque vous employez, nettoyez ou entretenez la plaque de cuisson.
1
2
- 9 -
DÉPANNAGE
Le brûleur ne s’ouvre pas lorsque
le bouton de De commande est
ouvert
A. Cest un problème avec la soupape à gaz (Contactez le
service à la clientèle).
B. La veilleuse du brûleur nest pas allumée
C. La pression du gaz est basse.(Contactez le service à la
clientèle).
Trop de chaleur
A. Les soupapes des brûleurs sont réglées trop haut
B. La ventilation est défectueuse
C. La pression du gaz est surestimée
D. Le brûleur est mal réglé
Chaleur inégale d’un côté à
l’autre
A. Les soupapes des brûleurs sont mal réglées
B. Lappareil nest pas au niveau dun côté à lautre
C. Le brûleur est mal réglé
Chaleur inégale de l’avant ver
l’arrière
A. Lappareil nest pas au niveau de lavant vers larrière
B. La ventilation est défectueuse
C. Le brûleur est mal réglé
La veilleuse d’allumage ne reste
pas allumée
A. La veilleuse dallumage est réglée trop bas. Réglez la
veilleuse dallumage pour permettre la circulation du gaz.
B. Obstruction de lorifice de la veilleuse dallumage
C. La pression du gaz est basse. (Contactez le service à la
clientèle).
Les flammes des brûleurs sont
jaunes
A. Ouvrez les obturateurs des brûleurs jusqu’à ce que les flammes
redeviennent bleues.
Les flammes des brûleurs sont
trop élévées
A. Fermez les obturateurs des sont trop élévées brûleurs jusqu’à ce
que les flammes touchent le brûleur.
La pression du gaz varie
A. Vérifiez si la prise d'air du régulateur est bouchée
- 8 -
ENTRETIEN
La plaque de cuisson et ses pièces sont chaudes. Faites
attention lorsque vous employez, nettoyez ou entretenez la plaque de cuisson.
LUBRIFICATION
On doit vérifier et lubrifier toutes les soupapes régulièrement. Contactez votre service à la
clientèle pour de plus amples détails.
SYSTÈME DE VENTILATION
La hotte à évacuation (système de ventilation) devrait être examinée et nettoyée au moins deux
fois par année.
SERVICE
Contactez votre service à la clientèle local pour toute réparation ou tout réglage nécessaire sur
cet équipement. Pour une liste des bureaux des services et des pièces, consultez
www.vulcanequipment.com.
Lorsque vous appelez pour du service, les renseignements suivants devraient être disponibles
sur la plaque d'identification de l'appareil : le numéro du modèle et le numéro de série.
- 7 -
RÉGLAGE DE LA VEILLEUSE DALLUMAGE
À laide dun tournevis à tête plate, tournez la vis à tête hexagonale fendue de réglage de la
veilleuse dallumage dans le sens des aiguilles d'une montre pour diminuer la flamme et dans le
sens contraire des aiguilles d'une montre pour augmenter la flamme. Voir Fig. 6.
NETTOYAGE
Les grilles peuvent tremper dans un détersif commercial toute la nuit. Au matin, rincez-les avec
de l'eau chaude pour enlever tout résidu du détersif. Rincez à fond et mettez de lhuile de
cuisson afin de prévenir la rouille.
Les orifices de combustion et le support des brûleurs devraient être nettoyés à fond. Le venturi
doit être libre de graisse et de poussière. Lors du nettoyage, ne pas insérer de pic dans les trous
des orifices de combustion le savon et leau sen chargeront normalement. Des éclaboussures
ou des débordements abondants nécessitent un nettoyage à laide dun produit pour nettoyer les
fours. Après le nettoyage, rincez avec leau propre et essuyez avec un linge sec. Assurez -vous
d'appliquer une mince couche dhuile de cuisson afin de protéger après le nettoyage.
Les surfaces en acier inoxydable peuvent être nettoyées à laide dun linge humide et dune
solution deau et dun savon doux.
Les endroits où la graisse ou la nourriture peuvent saccumuler doivent être régulièrement
nettoyés.
Fig. 6
Vis de réglage de la veilleuse d’allumage
- 6 -
moment être connectée à une pression dalimentation supérieure à ½ psi (3,45 kPa) ou 36 cm
CE.
Avant lallumage, vérifiez tous les joints dans la conduite
dalimentation en gaz pour les fuites. Utilisez une solution deau et savon. Ne pas
utiliser une flamme nue.
EMPLOI
La plaque de cuisson et ses pièces sont chaudes. Faites
attention lorsque vous employez, nettoyez ou entretenez la plaque de cuisson.
COMMANDES
Il y a une veilleuse dallumage pour deux brûleurs. La plaque de cuisson est munie de veilleuses
dallumage permanentes non contrôlées. Le gaz circulera à partir des veilleuses dès que
lalimentation principale en gaz de lappareil est ouverte. Voir la procédure dallumage de la
veilleuse ci-dessous.
Chaque brûleur est contrôlé indépendamment par une soupape de réglage infini de la chaleur.
Une fois que les veilleuses sont allumées, tourner le bouton de commande à la position OUVERT
allumera chaque brûleur. Les brûleurs seront complètement à la position OUVERT lorsque les
boutons de commande seront tournés jusquau bout vers la gauche. Les brûleurs seront
complètement à la position FERMÉ lorsque les boutons de commande seront tournés jusquau
bout vers
INSTRUCTIONS D'ALLUMAGE
1. Voir Fig. 5. Fermez le robinet d'arrêt principal
et tous les boutons de commande
et attendez 5 minutes pour permettre
à tout gaz accumulé de s’échapper.
2. Retirez les grilles.
3. Ouvrez le robinet d’arrêt principal du gaz.
Allumez la veilleuses d’allumage.
Réglez la vis de la soupape de la veilleuse
(voir Fig. 6) jusqu’à ce que laflamme de la
veilleuse ait une légère pointe jaune.
4. Pour allumer les brûleurs, ouvrez les
soupapes individuelles des brûleurs.
5. Si les brûleurs ne s’allument pas, fermez toutes
les soupapes ainsi que le robinet d’arrêt
principal du gaz et contactez un service à la
clientèle autorisé.
Veilleuses
d’allumage
Fig. 5
- 5 -
HOTTE DE VENTILATION
La plaque de cuisson devrait être installée sous une hotte de ventilation appropriée. Pour un
emploi sécuritaire et une ventilation adéquate, laissez un espace entre la plaque de cuisson et la
hotte à évacuation libre de toute obstruction.
CONNEXIONS DU GAZ
Toutes les connexions et toute pâte à joints doivent résister à laction du gaz propane.
Vider la conduite dalimentation pour la nettoyer de toute poussière, saleté ou tout autre corps
étranger avant de la connecter à lappareil.
Les codes exigent quun robinet darrêt du gaz soit installé dans la conduite de gaz à lavant de
lappareil. La conduite dalimentation en gaz doit être au moins léquivalent dun tuyau en fer de
2 cm.
Une alimentation adéquate en gaz est requise. Des conduites de dimension insuffisante ou à
basse pression limiteront le volume de gaz nécessaire pour une performance satisfaisante. On
recommande une pression d'alimentation minimum de 18 cm CE pour le gaz naturel et de 28 cm
CE pour le gaz propane. Avec tous les éléments fonctionnant en même temps, la pression
dadmission sur tous les éléments ne devrait pas démontrer une baisse not able.
Lorsque vous évaluez la tuyauterie de lalimentation en gaz, si les pressions dessai excèdent ½
psi (3,45 kPa), lappareil et son robinet darrêt individuel doivent être déconnectés de la
tuyauterie de lalimentation en gaz. Lorsque les pressions dessai sont de ½ psi (3,45 kPa) ou
moins, lappareil doit être isolé de la tuyauterie de lalimentation en gaz en fermant son robinet
darrêt individuel durant tout essai de la pression de la tuyauterie.
Avant lallumage, vérifiez tous les joints dans la conduite
dalimentation en gaz pour les fuites. Utilisez une solution deau et savon. Ne pas utiliser
une flamme nue.
INSTALLATION DU RÉGULATEUR DE PRESSION DU GAZ
Le régulateur de pression de gaz est réglé en usine à une pression de sortie de 13 cm de colonne
d’eau pour le gaz naturel et de 25 cm pour le gaz propane. Des réglages mineurs peuvent être requis
selon la pression de gaz spécifique au site.
Installez le régulateur aussi près que possible de la plaque de cuisson sur la conduite
dalimentation en gaz. Assurez-vous que la flèche au-dessous du régulateur est orientée dans la
direction de la circulation du gaz à la plaque de cuisson (Fig.1) et que le régulateur est placé
avec le bouchon daération ainsi que le couvercle de la prise de conversion (Fig. 2)
Fig. 1
Fig. 2
La pression d'alimentation minimum (en amont du régulateur) devrait être de 18 à 23 cm CE pour
le gaz naturel et de 28 à 30 cm CE pour le gaz propane. La plaque de cuisson ne devrait à aucun
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Vulcan VHP848 Le manuel du propriétaire

Catégorie
Cuisinières
Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues