Electrolux EFA90540X Manuel utilisateur

Catégorie
Hottes
Taper
Manuel utilisateur
EFA 90540 X
EFA 12540 X
Instructions Manual
Manuel d’Instructions
Bedienungsanleitung
Gebruiksaanwijzing
Kullanim Kilavuku
EN
2
2
Instructions Manual
INDEX
RECOMMENDATIONS AND SUGGESTIONS......................................................................................................................7
CHARACTERISTICS..............................................................................................................................................................8
INSTALLATION....................................................................................................................................................................10
USE.......................................................................................................................................................................................14
MAINTENANCE....................................................................................................................................................................16
FR
3
3
Manuel d’Instructions
SOMMAIRE
CONSEILS ET SUGGESTIONS ..........................................................................................................................................18
CARACTERISTIQUES.........................................................................................................................................................19
INSTALLATION....................................................................................................................................................................21
UTILISATION........................................................................................................................................................................25
ENTRETIEN..........................................................................................................................................................................27
DE
4
4
Bedienungsanleitung
INHALTSVERZEICHNIS
EMPFEHLUNGEN UND HINWEISE....................................................................................................................................29
CHARAKTERISTIKEN..........................................................................................................................................................30
MONTAGE............................................................................................................................................................................32
BEDIENUNG.........................................................................................................................................................................36
WARTUNG............................................................................................................................................................................38
NL
5
5
Gebruiksaanwijzing
INHOUDSOPGAVE
ADVIEZEN EN SUGGESTIES.............................................................................................................................................40
EIGENSCHAPPEN...............................................................................................................................................................41
INSTALLATIE .......................................................................................................................................................................43
GEBRUIK..............................................................................................................................................................................47
ONDERHOUD ......................................................................................................................................................................49
TR
6
6
Kullanim Kilavuku
IÇERIKLER
TAVSIYELER VE ÖNERILER..............................................................................................................................................51
ÖZELLIKLER........................................................................................................................................................................52
MONTAJ...............................................................................................................................................................................54
KULLANIM............................................................................................................................................................................58
BAKIM...................................................................................................................................................................................60
EN
7
7
RECOMMENDATIONS AND SUGGESTIONS
The Instructions for Use apply to several versions of this appliance. Ac-
cordingly, you may find descriptions of individual features that do not ap-
ply to your specific appliance.
INSTALLATION
The manufacturer will not be held liable for any damages resulting from
incorrect or improper installation.
The minimum safety distance between the cooker top and the extractor
hood is 650 mm.
Check that the mains voltage corresponds to that indicated on the rating
plate fixed to the inside of the hood.
For Class I appliances, check that the domestic power supply guarantees
adequate earthing.
Connect the extractor to the exhaust flue through a pipe of minimum di-
ameter 120 mm. The route of the flue must be as short as possible.
Do not connect the extractor hood to exhaust ducts carrying combustion
fumes (boilers, fireplaces, etc.).
If the extractor is used in conjunction with non-electrical appliances (e.g.
gas burning appliances), a sufficient degree of aeration must be guaran-
teed in the room in order to prevent the backflow of exhaust gas. The
kitchen must have an opening communicating directly with the open air in
order to guarantee the entry of clean air.
USE
The extractor hood has been designed exclusively for domestic use to
eliminate kitchen smells.
Never use the hood for purposes other than for which it has ben designed.
Never leave high naked flames under the hood when it is in operation.
Adjust the flame intensity to direct it onto the bottom of the pan only, mak-
ing sure that it does not engulf the sides.
Deep fat fryers must be continuously monitored during use: overheated oil
can burst into flames.
Do not flambè under the range hood; risk of fire
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience
and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play with the
appliance
MAINTENANCE
Switch off or unplug the appliance from the mains supply before carrying
out any maintenance work.
Clean and/or replace the Filters after the specified time period.
Clean the hood using a damp cloth and a neutral liquid detergent.
650 mm min.
EN
8
8
CHARACTERISTICS
Dimensions
650 min.
EN
9
9
Components
Ref. Q.ty Product Components
1 1 Hood Body, complete with: Controls, Light, Blower,
Filters
2 1 Telescopic Chimney comprising:
2.1 1 Upper Section
2.2 1 Lower Section
7.1 1 Telescopic frame complete with extractor, consisting of:
7.1a 1 Upper frame
7.1b 1 Lower frame
9 1 Reducer Flange ø 150-120 mm
10 1 Flange ø 150
10a 1 Dumper ø 150mm
15 1 Air Outlet Connection
24 1 Junction box
25 2 Pipe clamps
Ref. Q.ty Installation Components
11 4 Wall Plugs ø 10
12c 6 Screws 2,9 x 6,5
12e 2 Screws 2,9 x 9,5
12f 4 Screws M6 x 10
12g 4 Screws M6 x 80
12h 4 Screws 5,2 x 70
21 1 Drilling template
22 4 6.4 mm int. dia washers
23 4 M6 nuts
Q.ty Documentation
1 Instruction Manual
12c
7.1a
7.1
22
23
12h
7.1b
2
2.1
2.2
12c
11
21
12g
1
12f
24
12e
15
12c
25
10
9
10a
EN
1
0
10
INSTALLATION
Drilling the Ceiling/shelf and fixing the frame
DRILLING THE CEILING/SHELF
Use a plumb line to mark the centre of the hob on the ceiling/support shelf.
Place the drilling template 21 provided on the ceiling/support shelf, making sure that the
template is in the correct position by lining up the axes of the template with those of the hob.
Mark the centres of the holes in the template.
Drill the holes at the points marked:
• For concrete ceilings, drill for plugs appropriate to the screw size.
• For hollow brick ceilings with wall thickness of 20 mm: drill ø 10 mm(immediately insert
the Dowels 11 supplied).
• For wooden beam ceilings, drill according to the wood screws used.
• For wooden shelf, drill ø 7 mm.
• For the power supply cable feed, drill ø 10 mm.
• For the air outlet (Ducted Version), drill according to the diameter of the external air ex-
haust duct connection.
Insert two screws of the following type, crossing them and leaving 4-5 mm from the ceiling:
• For concrete ceilings, use the appropriate plugs for the screw size (not provided).
• for Cavity ceiling with inner space, with wall thickness of approx. 20 mm, Screws 12h,
supplied.
• For wooden beam ceilings, use 4 wood screws (not provided).
• For wooden shelf, use 4 screws 12g with washers 22 and nuts 23, provided.
EN
1
1
11
Fixing the frame
Loosen the two screws fastening the lower chimney and re-
move this from the lower frame.
Loosen the two screws fastening the upper chimney and re-
move this from the upper frame.
If you wish to adjust the height of the frame, proceed as follows:
Unfasten the eight metric screws joining the two columns, lo-
cated at the sides of the frame.
Adjust the frame to the height required, then replace all the
screws removed as above.
Insert the upper chimney stack from above, and leave it run-
ning free on the frame.
• Lift up the frame, fit the frame slots onto the screws up to the
slot end positions.
Tighten the two screws and fasten the other two screws pro-
vided with the hood.
Before tightening the screws completely it is possible to adjust
the frame by turning it. Make sure that the screws do not come
out of their seats in the slotted holes.
The frame mountings must be secure to withstand the weight
of the hood and any stresses caused by the occasional side
thrust applied to the device.
On completion, check that the base is stable, even if the frame
is subjected to bending.
In all cases where the ceiling is not strong enough at the sus-
pension point, the installer must provide strengthening using
suitable plates and backing pieces anchored to the structurally
sound parts.
2
2
1
1
EN
1
2
12
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 120mm, the
choice of which is left to the installer.
To install a ø 150
To install the dumper 10a.
Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
To install a ø 120
To install a ø 120 mm air exhaust connection, insert the re-
ducer flange 9 on the dumper 10a.
Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
Remove any activated charcoal filters.
ø 120
25
9
10a
10a
ø 150
25
Recirculation version air outlet
Fix the connection 15 to the frame using the 4 screws pro-
vided.
Fix the flange 10 to the lower opening of the connection 15.
Connect the hood air outlet to the flange in the lower part of
the junction using a rigid or flexible ø 150 tube (by installer’s
choice).
15
10
EN
1
3
13
Flue assembly - Mounting the hood body
Position the upper chimney section and fix the upper part to the
frame using the 2 screws 12c (2,9 x 6,5) provided.
Similarly, position the lower chimney section and fix the
lower part to the frame using the 2 screws 12c (2,9 x 6,5) pro-
vided.
Before fixing the hood body to the frame:
Remove the grease filters from the hood body.
Remove any activated charcoal filters.
From below, use the 4 screws 12f (M6 x 10)provided to fix the
hood body to the frame.
12f
12c
12c
ELECTRICAL CONNECTION
• Connect the hood to the mains through a two-pole switch hav-
ing a contact gap of at least 3 mm.
Remove the grease filters (see paragraph Maintenance) being
sure that the connector of the feeding cable is correctly inserted
in the socket placed on the side of the fan.
Connect the control connector Cmd.
Connect the lights connector Lux.
Place the connectors in the junction box 24 and close it using
the 2 screws 12e (2,9 x 9,5) provided.
Fix the junction box to the hood body using the 2 screws 12c
(2,9 x 6,5) provided.
• For the recirculation version, fit the activated carbon odour fil-
ter.
Replace the grease filters.
24
12e
Cmd
12c
Lux
EN
1
4
14
USE
L T1 T2 T3 T4 T5 F
The hood can be switched on pushing directly onto the requested speed without firstly hav-
ing to select 0/1 button .
Basic functions
Touch
control
Dual Function
Indicator lights
When briefly pressed it switches the lighting system
on and off.
Touch control unlit Lights off
Touch control lit Lights on
L
When pressed for 2 seconds it starts the lighting
system in “courtesy light” mode. The lamps are
fed at a reduced power of approximately 5W.
Such function can be stopped by pressing the
touch control for 2 seconds or just by pressing it
shortly in order to return to the normal lighting
mode. In courtesy light mode the touch control is
not lit.
Touch control unlit
Courtesy light on
Touch control lit Motor on
T1
When pressed the motor is stopped, regardless of the
speed it is set to.
Touch control unlit Motor off
T2
When pressed the motor is set to the first speed
Touch control lit
By a brief pressing the motor is set to the second
speed.
Touch control lit Second speed on
T3
By pressing the touch control for approximately 2
seconds the Delay function is enabled, i.e dela-
yed shutdown of the appliance ensuring a com-
plete elimination of the residual odours. This fun-
ction can be activated at OFF-position and at 1°,
and 3°speeds. It can be stopped in advance
by pressing any of the touch controls (T) with the
exception of T3. The Delay function works accor-
ding to the following scheme:
speed / OFF = 20 minuets
speed = 15 minutes
speed = 5 minutes
Flashing touch
control
Delay function on
T4
When pressed the motor is set to the third speed
Touch control lit
EN
1
5
15
Touch
control
Basic functions Indicator lights
T5
When pressed the motor is set to the intensive speed
timed to 5 minutes. At the end of 5 minutes of intensi-
ve speed the hood starts again at the speed it was set
to previously. In case the hood is set to the intensive
speed directly from OFF-state it will then start from
the first speed after 5 minutes of intensive speed.
Touch control lit
Touch control lit
Metal grease filters satu-
ration alarm. Metal grease
filters need to be washed.
The alarm starts up after
100 working hours.
F
When pressed for 4 seconds it resets the filter alarm
signal indicated by flashing of the touch control T1.
This procedure can be carried out only when the
motor is stopped.
Flashing touch
control
Charcoal odour filter satu-
ration alarm. Charcoal
filter has to be replaced
and metal grease filters
washed. The alarm starts
up after 200 working
hours. (Activation; check
the paragraph “Odour
filter”)
EN
1
6
16
MAINTENANCE
REMOTE CONTROL (OPTIONAL)
The appliance can be controlled using a remote control powered
by a 1.5 V carbon-zinc alkaline batteries of the standard LR03-
AAA type.
Do not place the remote control near to heat sources.
Used batteries must be disposed of in the proper manner.
Grease filters
CLEANING OF THE METAL CASSETTE FILTERS
Alarm reset
Stop the motor.
• Press the F -touch control for at least 4 seconds until the T1 -
touch control flashes.
Cleaning the filters
Filters can be washed in the dish machine. They need to be
washed every 2 months or even more frequently in case of par-
ticularly intensive use of the hood.
Remove the filters one by one pushing them towards the back
side of the unit and simultaneously pulling downwards.
Any kind of bending of the filters has to be avoided when
washing them. Before fitting them again into the hood make
sure that they are completely dry.
When fitting the filters into the hood pay attention that they are
mounted in correct position and that the handle faces outwards.
EN
1
7
17
Odour filter (Recirculation Version)
This filter cannot be washed or regenerated, and must be replaced when the F touch control starts
to flash, or at least once every 4 months. The alarm is only triggered when the motor is on.
Enabling/Disabling the alarm signal
In Recirculation Version Hoods, the Filter saturation Alarm must be enabled at the time of
installation or later.
Switch off the lights and the motor.
Disconnect the mains power supply to the hood by removing the motor unit power supply
cable connector, switching off the power supply at the Mains or turning the Main switch off.
Restore the connection, pressing and holding T2.
Release the touch control, touch controls L, T2 and F will light up normally.
Within 3 seconds press the touch control F until the key itself flashes to confirm as follows:
2 flashes – Charcoal odour Filter saturation Alarm ENABLED
1 flash - Charcoal odour Filter saturation Alarm DISABLED
REPLACING THE CHARCOAL ODOUR FILTER
Reset the alarm signal
Stop the motor.
• Press the touch control F for at least 4 seconds, until the touch
control T1 flashes.
Replace the Filter
Remove the metal grease filters.
• Remove the saturated charcoal filter, turning the fasteners pro-
vided.
Fit the new filter and fasten it its correct position.
Put the metal grease filters in their seats.
Lighting
LIGHT REPLACEMENT
20 W halogen light.
Remove the 2 screws fixing the Lighting support, and pull it
out of from the Hood.
Extract the lamp from the Support.
Replace with another of the same type, making sure that the
two pins are properly inserted in the lamp holder socket holes.
• Replace the Support, fixing it in place with the two screws re-
moved as above.
FR
1
8
18
CONSEILS ET SUGGESTIONS
La présente notice d'emploi vaut pour plusieurs versions de l'appareil. Elle
peut contenir des descriptions d'accessoires ne figurant pas dans votre appa-
reil.
INSTALLATION
Le fabricant décline toute responsabilité en cas de dommage dû à une installa-
tion non correcte ou non conforme aux règles de l’art.
La distance minimale de sécurité entre le plan de cuisson et la hotte doit être
de 650 mm au moins.
Vérifier que la tension du secteur correspond à la valeur qui figure sur la pla-
quette apposée à l’intérieur de la hotte.
Pour les Appareils appartenant à la I
ère
Classe, veiller à ce que la
mise à la terre de l’installation électrique domestique ait été effectuée confor-
mément aux normes en vigueur.
Connecter la hotte à la sortie d’air aspiré à l’aide d’une tuyauterie
d’un diamètre égal ou supérieur à 120 mm. Le parcours de la
tuyauterie doit être le plus court possible.
Eviter de connecter la hotte à des conduites d’évacuation de fumées
issues d’une combustion tel que (Chaudière, cheminée, etc…).
Si vous utilisez des appareils qui ne fonctionnent pas à l’électricité
dans la pièce ou est installée la hotte (par exemple: des appareils
fonctionnant au gaz), vous devez prévoir une aération suffisante du milieu. Si
la cuisine en est dépourvue, pratiquez une ouverture qui communique avec
l’extérieur pour garantir l’infiltration de l’air pur.
UTILISATION
• La hotte a été conçue exclusivement pour l’usage domestique, dans le but
d’éliminer les odeurs de la cuisine.
Ne jamais utiliser abusivement la hotte.
Ne pas laisser les flammes libres à forte intensité quand la hotte est en ser-
vice.
Toujours régler les flammes de manière à éviter toute sortie latérale
de ces dernières par rapport au fond des marmites.
Contrôler les friteuses lors de l’utilisation car l’huile surchauffée
pourrait s’enflammer.
Ne pas préparer d’aliments flambés sous la hotte de cuisine : risque d’incendie
Cet appareil ne doit pas être utilisé par des personnes (y compris les enfants)
ayant des capacités psychiques, sensorielles ou mentales réduites, ni par des
personnes n’ayant pas l’expérience et la connaissance de ce type d’appareils,
à moins d'être sous le contrôle et la formation de personnes responsables de
leur sécurité.
• Les enfants doivent être surveillés pour s'assurer qu'ils ne jouent pas avec
l'appareil.
ENTRETIEN
Avant de procéder à toute opération d’entretien, retirer la hotte en retirant la
fiche ou en actionnant l’interrupteur général.
• Effectuer un entretien scrupuleux et en temps dû des Filtres, à la cadence
conseillée.
Pour le nettoyage des surfaces de la hotte, il suffit d’utiliser un chiffon humide
et détersif liquide neutre.
650 mm min.
FR
1
9
19
CARACTERISTIQUES
Encombrement
650 min.
FR
2
0
20
Composants
Réf. Q.té Composants de Produit
1 1 Corps Hotte équipé de: Comandes, Lumière, Filtres
2 1 Cheminée Télescopique formée de :
2.1 1 Cheminée Supérieure
2.2 1 Cheminée Inférieure
7.1 1 Treillis télescopique avec Aspirateur, formé par:
7.1a 1 Treillis supérieur
7.1b 1 Treillis inférieur
9 1 Flasque de Réduction ø 150-120 mm
10 1 Flasque ø 150
10a 1 Buse avec clapet ø 150
15 1 Raccord Sortie Air
24 1 Boîte connexions
25 2 Colliers de serrage serre-tube
Réf. Q.té Composants pour l’installation
11 4 Chevilles ø 10
12c 6 Vis 2,9 x 6,5
12e 2 Vis 2,9 x 9,5
12f 4 Vis M6 x 10
12g 4 Vis M6 x 80
12h 4 Vis 5,2 x 70
21 1 Gabarit de perçage
22 4 Rondelles øi 6,4
23 4 Écrous M6
Q.té Documentation
1 Manuel d’instructions
12c
7.1a
7.1
22
23
12h
7.1b
2
2.1
2.2
12c
11
21
12g
1
12f
24
12e
15
12c
25
10
9
10a
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64

Electrolux EFA90540X Manuel utilisateur

Catégorie
Hottes
Taper
Manuel utilisateur