Zephyr ZGE-E30AS Manuel utilisateur

Catégorie
Hottes
Taper
Manuel utilisateur
Use, Care, and Installation Guide
www.zephyronline.com
Model number:
Serial Number:
APR19.0501 © Zephyr Ventilation LLC.
Genova
ZGE-E30AS
ZGE-E36AS
ZGE-E30AS290
ZGE-E36AS290
www.zephyronline.com
1
SAFETY NOTICE ................................................................. 2-3
LIST OF MATERIALS ....................................................... 4
INSTALLATION
Ducting Calculation Sheet
....................................... 5
Mounting Height & Clearance
................................ 6
Ducting Options
........................................................... 7
+RRG6SHFL¿FDWLRQV
................................................... 8
Preparing the Cabinet
............................................... 9
Installing the Hood
...................................................... 10 - 12
Ductless Recirculation
.............................................. 13
FEATURES & CONTROLS
Touch Controls
.............................................................. 14-15
Remote Control (Optional)
....................................... 16
MAINTENANCE
Hood and Filter Cleaning
......................................... 17
Lights
................................................................................ 18
Wiring Diagram
............................................................ 19
TROUBLESHOOTING
................................................................ 20
LIST OF PARTS AND ACCESSORIES
.............................. 21
WARRANTY
.................................................................................... 22
PRODUCT REGISTRATION
.................................................... 23
Table of Contents
Important Safety Notice
READ AND SAVE THESE INSTRUCTIONS
2
www.zephyronline.com
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE.
WARNING
TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer.
E %HIRUHVHUYLFLQJRUFOHDQLQJXQLWVZLWFKSRZHURႇDWVHUYLFHSDQHODQGORFNSDQHOWRSUHYHQWSRZHUIURPEHLQJVZLWFKHGRQDFFLGHQWDOO\
:KHQWKHVHUYLFHGLVFRQQHFWLQJPHDQVFDQQRWEHORFNHGVHFXUHO\IDVWHQDSURPLQHQWZDUQLQJGHYLFHVXFKDVDWDJWRWKHVHUYLFH
panel.
CAUTION
)RUJHQHUDOYHQWLODWLQJXVHRQO\'RQRWXVHWRH[KDXVWKD]DUGRXVRUH[SORVLYHPDWHULDOVDQGYDSRUV7DNHFDUHZKHQXVLQJFOHDQLQJ
DJHQWVRUGHWHUJHQWV6XLWDEOHIRUXVHLQKRXVHKROGFRRNLQJDUHD
WARNING
TO REDUCE THE RISK OF RANGE TOP GREASE FIRE:
D 1HYHUOHDYHVXUIDFHXQLWVXQDWWHQGHGDWKLJKVHWWLQJV%RLORYHUVFDXVHVPRNLQJDQGJUHDV\VSLOORYHUVWKDWPD\LJQLWH+HDWRLOVVORZO\
on low or medium settings.
E $OZD\VWXUQKRRG21ZKHQFRRNLQJDWKLJKKHDWRUZKHQÀDPLQJIRRG
F &OHDQYHQWLODWLQJIDQVIUHTXHQWO\*UHDVHVKRXOGQRWEHDOORZHGWRDFFXPXODWHRQIDQRU¿OWHU
G 8VHSURSHUSDQVL]H$OZD\VXVHFRRNZDUHDSSURSULDWHIRUWKHVL]HRIWKHVXUIDFHHOHPHQW
H .HHSIDQ¿OWHUVDQGJUHDVHODGHQVXUIDFHVFOHDQ
f. Use high setting on hood only when necessary.
J 'RQ¶WOHDYHKRRGXQDWWHQGHGZKHQFRRNLQJ
K $OZD\VXVHFRRNZDUHDQGXWHQVLOVDSSURSULDWHIRUWKHW\SHRIDQGDPRXQWRIIRRGEHLQJSUHSDUHG
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE, OBSERVE THE FOLLOWING:
D 6027+(5)/$0(6ZLWKDFORVH¿WWLQJOLGFRRNLHVKHHWRUPHWDOWUD\WKHQWXUQRႇWKHEXUQHU%(&$5()8/7235(9(17%8516
,IWKHÀDPHVGRQRWJRRXWLPPHGLDWHO\(9$&8$7($1'&$//7+(),5('(3$570(17
b. NEVER PICK UP A FLAMING PAN – You may be burned.
c. DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.
d. Use an extinguisher ONLY if:
 <RXNQRZ\RXKDYHD&ODVV$%&H[WLQJXLVKHUDQG\RXDOUHDG\NQRZKRZWRRSHUDWHLW
 7KH¿UHLVVPDOODQGFRQWDLQHGLQWKHDUHDZKHUHLWVWDUWHG
 7KH¿UHGHSDUWPHQWLVEHLQJFDOOHG
 <RXFDQ¿JKWWKH¿UHZLWK\RXUEDFNWRDQH[LW
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
D ,QVWDOODWLRQZRUNDQGHOHFWULFDOZLULQJPXVWEHGRQHE\TXDOL¿HGSHUVRQVLQDFFRUGDQFHZLWKDOODSSOLFDEOHFRGHVDQGVWDQGDUGV
,QFOXGLQJ¿UHUDWHGFRQVWUXFWLRQ
E 6XႈFLHQWDLULVQHHGHGIRUSRZHUFRPEXVWLRQDQGH[KDXVWLQJRIJDVHVWKURXJKWKHÀXHFKLPQH\RIIXHOEXUQLQJHTXLSPHQWWRSUHYHQW
EDFNGUDIWLQJ)ROORZWKHKHDWLQJHTXLSPHQWPDQXIDFWXUHU¶VJXLGHOLQHDQGVDIHW\VWDQGDUGVVXFKDVWKRVHSXEOLVKHGE\WKH1DWLRQDO
Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and
the local code authorities.
c. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
d. Ducted fans must always vent to the outdoors.
e. NEVER place a switch where it can be reached from a tub or shower.
I 0DNHVXUHWKHSRZHULVRႇEHIRUHLQVWDOOLQJZLULQJRUPDLQWHQDQFLQJ
Important Safety Notice
3
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
CAUTION
7RUHGXFHULVNRI¿UHDQGWRSURSHUO\H[KDXVWDLURXWVLGH'RQRWYHQWH[KDXVWDLULQWRVSDFHVZLWKLQZDOOVFHLOLQJV
attics, crawl spaces or garages. Hood not intended for installation over an outdoor grill.
OPERATION
$OZD\VOHDYHVDIHW\JULOOHVDQG¿OWHUVLQSODFH:LWKRXWWKHVHFRPSRQHQWVRSHUDWLQJEORZHUVFRXOGFDWFKRQWRKDLU¿QJHUV
and loose clothing.
The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation,
maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to
negligence and the warranty of the unit automatically expires due to improper maintenance.
*NOTE: Please check www.zephyronline.com for revisions before doing any custom work.
ELECTRICAL REQUIREMENTS
Important:
Observe all governing codes and ordinances.
It is the customer’s responsibility:
 7RFRQWDFWDTXDOL¿HGHOHFWULFDOLQVWDOOHU
- To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70
latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and
all local codes and ordinances.
,IFRGHVSHUPLWDQGDVHSDUDWHJURXQGZLUHLVXVHGLWLVUHFRPPHQGHGWKDWDTXDOL¿HGHOHFWULFLDQGHWHUPLQHWKDWWKH
ground path is adequate.
Do not ground to a gas pipe.
&KHFNZLWKDTXDOL¿HGHOHFWULFLDQLI\RXDUHQRWVXUHWKHUDQJHKRRGLVSURSHUO\JURXQGHG
Do not have a fuse in the neutral or ground circuit.
1DWLRQDO)LUH3URWHFWLRQ$VVRFLDWLRQ%DWWHU\PDUFK3DUN4XLQF\0DVVDFKXVHWWV
** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575
This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit
SURWHFWHGE\DRUDPSHUHFLUFXLWEUHDNHURUWLPHGHOD\IXVH:LULQJPXVWEHZLUHZLWKJURXQG3OHDVHDOVRUHIHUWR
Electrical Diagram on product.
$FDEOHORFNLQJFRQQHFWRUQRWVXSSOLHGPLJKWDOVREHUHTXLUHGE\ORFDOFRGHV&KHFNZLWKORFDOUHTXLUHPHQWVSXUFKDVH
and install appropriate connector if necessary.
ZGE-E30AS, ZGE-E36AS - 370 Watts, 3.5 Amps
ZGE-E30AS290, ZGE-E36AS290 - 167 Watts, 3.5 Amps
Cancer and Reproductive Harm - www.P65Warnings.ca.gov
WARNING:
Prop. 65 Warning for California Residents
List of Materials
4
www.zephyronline.com
(3) Wire Nuts
(1) Suction Cup
(1) 6” round damper (pre-installed)
(1) hood body with sliding glass
(2) upper installation brackets
(2) lower installation brackets
(1) filler panel (pre-installed)
(1) hardware package
MODELS: ZGE-E30AS, ZGE-E30AS290, ZGE-E36AS, ZGE-E36AS290
PARTS SUPPLIED
HARDWARE PACKAGE CONTENTS
PARTS NOT SUPPLIED
- Ducting, conduit and all installation tools
- Cable connector (if required by local codes)
- Recirculating kit accessory - ZRC-00GE
- Remote control accessory - 14000005
(2) halogen lights, GU-10 50W
(1) decorative mesh filter
(2) M4 x 8 (2) M4 x 1”
(4) 3/16 x 3/8”
(4) 3/16 x 1”
5
Duct pieces
Tot a l
Equivalent number
length x used =
3- 1/ 4” x 10”
Rect.,
straight
1 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect. to
6” round
transition
5 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect. to
6” round
transition
90
0
elbow
20 Ft. x ( ) =
Ft.
6”, 7”, 8”, 10”
Round,
90
0
15 Ft.
x ( ) =
Ft.
6”, 7”, 8”, 10”
Round,
45
0
9 Ft. x ( ) =
Ft.
Ft.
6”, 7”, 8”, 10”
Round,
straight
1 Ft. x ( ) =
Ft.
Subtotal column 1 =
Duct pieces
Tot a l
Equivalent number
length x used =
6”, 7”, 8”, 10”
Round, wall
cap with
damper
30 Ft. x ( ) =
Ft.
Ft.
Ft.
Ft.
6”, 7”, 8”, 10”
Round
roof cap
30 Ft. x ( ) =
Ft.
Subtotal column 2 =
Subtotal column 1 =
Total ductwork =
Maximum Duct Length: For satisfactory air movement,
the total duct length
should not exceed 100 equivalent feet.
6” round to
3- 1/ 4” x 10”
rect.
transition
1 Ft. x ( ) =
Ft.
6” round to
3- 1/ 4” x 10”
rect.
transition
90
0
elbow
16 Ft. x ( ) =
Ft.
7” round to
3 1/4” x 10”
rect.
transition
8 Ft. x ( ) =
Ft.
7” round to
3- 1/ 4” x 10”
rect.
transition
90
0
elbow
23 Ft. x ( ) =
Ft.
elbow
elbow
7” to 6” or
8” to 7” Round
tapered
reducer
25 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect. 90
0
elbow
15 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect. 45
0
elbow
9 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect. 90
0
flat elbow
24 Ft. x ( ) =
Ft.
3- 1/ 4” x 10”
Rect.
wall cap
with damper
30 Ft. x ( ) =
Ft.
Ft. x ( ) =
Ft.
15
6”, 7“, 8”
Round
in-line
damper
Installation – Ducting Calculation Sheet
Installation – Installing the Hood
6
www.zephyronline.com
DUCTING
A minimum of 6” round ducting must be used to
PDLQWDLQPD[LPXPDLUÀRZHႈFLHQF\
Always use rigid type metal ducts only. Flexible
GXFWVFRXOGUHVWULFWDLUÀRZE\XSWR
8VHFDOFXODWLRQZRUNVKHHWWRFRPSXWHWRWDOGXFW
ZRUN
ALWAYS, when possible, reduce the number of
transitions and turns. If a long duct run is required,
increase duct size from 6” to 7” or 8”.
If turns or transitions are required: Install as far
away from opening and as far apart, between 2,
as possible.
36”
24” min.
32” max.
0RXQWLQJKHLJKWIURPWRSRIFRRNLQJVXUIDFHWR
bottom of hood should be no less than 24” and no
more than 32”.
It is important to install the hood at the proper
mounting height. Hoods mounted too low could
UHVXOWLQKHDWGDPDJHDQG¿UHKD]DUGZKLOHKRRGV
mounted too high will be hard to reach and will
ORVHSHUIRUPDQFHDQGHႈFLHQF\
If available, also refer to range manufacturer’s
height clearance requirements and recommended
KRRGPRXQWLQJKHLJKWDERYHUDQJH$OZD\VFKHFN
\RXUORFDOFRGHVIRUDQ\GLႇHUHQFHV
DAMAGE-SHIPMENT / INSTALLATION:
Please fully inspect unit for damage before
installation.
If the unit is damaged in shipment, return the
unit to the store in which it was bought for
repair or replacement.
If the unit is damaged by the customer, repair
or replacement is the responsibility of the
customer.
If the unit is damaged by the installer (if other
than the customer), repair of replacement must
be made by arrangement between customer
and installer.
7
WARNING FIRE HAZARD
1(9(5H[KDXVWDLURUWHUPLQDWHGXFWZRUNLQWRVSDFHVEHWZHHQZDOOVFUDZOVSDFHVFHLOLQJDWWLFVRUJDUDJHV
All exhaust must be ducted to the outside, unless using the recirculating option.
8VHVLQJOHZDOOULJLG0HWDOGXFWZRUNRQO\
)DVWHQDOOFRQQHFWLRQVZLWKVKHHWPHWDOVFUHZVDQGWDSHDOOMRLQWVZFHUWL¿HG6LOYHU7DSHRU'XFW7DSH
Ducting Options Example
Installation – Ducting Options
soffit or crawl space
roof pitch w/
flashing & cap
ductless
recirculating
w/ gravity damper
side wall cap
ductless
recirculating
soffit
8
www.zephyronline.com
Installation – +RRG6SHFL¿FDWLRQV
front of hood
side of hood
top of hood
500mm
19
11
16
"
76mm
3"
280mm
11"
912mm
35
7
8
"
760mm
29
15
16
"
242mm
9
1
2
"
153mm
6
"
197mm
7
3
4
"
180mm
7
1
16
"
16mm
5
8
"
445mm
17
1
2
"
473mm
to
18
5
8
"
286mm
11
1
4
"
6mm
1
to
4
"
1
3
8
"
35mm
153mm
6
"
41mm
5
8
"
1
28mm
1
8
"
1
junction box
blower outlet
9
7
3/4
7”
9-
7/8”
19-7/8”
C/L
1
-
9/16”
Installation – Preparing the Cabinet
Fig.1
front edge
glass handle
Fig.2
1. 'HWHUPLQHDQGPDUNFHQWHUOLQHRQZDOODQGFDELQHWERWWRPZLWKDSHQFLO
,IWKHFDELQHWERWWRPLVUHFHVVHGZRRGEORFNLQJPXVWEHLQVWDOOHGWRHQVXUHSURSHU 
DOLJQPHQWRIWKHKRRGZLWKWKHFDELQHWERWWRP:RRGEORFNLQJVKRXOGEHÀXVK 
within cabinet bottom.
3. Follow the dimensions in Fig.1 and cut-out the bottom of your cabinet to create an opening
IRUWKHKRRGWR¿WWKURXJK,I\RXKDYHDIUDPHOHVVFDELQHWEHJLQWKH´PHDVXUHPHQW
(referenced in Fig.1) from front of the cabinet door. This way the front edge of the hood will
EHÀXVKZLWKWKHFDELQHWGRRUVZKHQFORVHGVHH)LJ
10
www.zephyronline.com
Installation – Installing the Hood
WARNING: Electrical wiring must be done by a qualified person(s) in
accordance with all applicable codes and standards. This range hood must be
properly grounded. Turn off electrical power at service entrance before wiring.
!
1) Prepare electrical wiring and ducting in cabinet. Location of junction box and blower outlet can be found on page 8.
2) Unscrew the (10) screws from front panel and place
the panel aside, Fig.3. You will now have access to the
interrior of the range hood.
Fig.3 Fig.4
3) Open cabinet doors. Lift range hood and slide it through
the opening located in the bottom of the cabinet, Fig.4.
0DNHVXUHRSHQLQJPDWFKHVWKHGLPHQVLRQVRQSDJH
Fig.1.
4) There are spring clips located on the left and right sides
of the hood body which will temporarily hold the hood in
place, Fig.5.
Fig.5 Fig.6
6HFXUHXSSHUEUDFNHWVWROHIWDQGULJKWVLGHVRIKRRG
ERG\E\XVLQJ[´VFUHZVIRUHDFKEUDFNHW
)LJ0DNHVXUHWKHFDSWLYHQXWVFUHZKROHVRQ
WKHEUDFNHWDUHIDFLQJGRZQZDUG1RWH'XHWROLPLWHG
ZRUNVSDFHLQ´FDELQHWV\RXZLOOQHHGWRXVHDULJKW
angle or 2” long Philips head screwdriver.
1
2
Installation – Installing the Hood
11
3ODFHORZHULQVWDOODWLRQEUDFNHWVXQGHUXSSHULQVWDOODWLRQ
EUDFNHWVORFDWHGRQOHIWDQGULJKWVLGHVRIKRRGERG\
Fig.7. Note: The wider portion of the lower installation
EUDFNHWVKRXOGEHDWWKHERWWRP
Fig.7 Fig.8
7) From inside the hood, secure (1) M4x8 screw into
HDFKORZHULQVWDOODWLRQEUDFNHW7KHSRVLWLRQRIWKLV
screw is adjustable to accomodate various cabinet
ERWWRPWKLFNQHVVHV)LJ'RQRWIXOO\WLJKWHQVFUHZ\HW
8) Install (2) 3/16x1” screws into the captive nuts of each
XSSHULQVWDOODWLRQEUDFNHW7LJKWHQVFUHZVWRDGMXVWWKH
height of range hood until there is no gap between the
cabinet bottom and front edge of hood, Fig.9. After hood
LVSRVLWLRQHGIXOO\WLJKWHQWKHORZHULQVWDOODWLRQEUDFNHW
screw from step 7, Fig.8-1.
Fig.9 Fig.10
$¿OOHUSDQHOLVLQFOXGHGWRDFFRPRGDWHPXOWLSOHFDELQHW
depths. Inside the hood are (2) thumb screws located
RQWKHOHIWDQGULJKWVLGHVDWWKHEDFNRIWKHKRRG 
)LJ$7XUQHDFKWKXPEVFUHZFORFNZLVHWRSXVK
WKH¿OOHUSDQHOWRZDUGVWKHZDOO)LJ%7LJKWHQWKXPE
VFUHZVXQWLO¿OOHUSDQHOPHHWVWKHZDOODQGLVVHFXUHGLQ
SODFH6HHKRRGVSHFL¿FDWLRQVRQSDJHIRUVXSSRUWHG
cabinet depths.
A
B
1
2
1
Installation – Installing the Hood
12
www.zephyronline.com
A
10) Place 6” round ducting over blower collar and secure
with aluminum duct tape. If using hood in ductless
recirculating mode turn to page 13.
,QVWDOOHOHFWULFDOZLULQJ1RWH$FDEOHORFNQRW 
LQFOXGHGPD\EHUHTXLUHGE\ORFDOFRGHV&KHFN
with local requirements and codes, purchase and install
appropriate connector if necessary.
0DNHVXUHQRSDFNLQJPDWHULDOLVLQVLGHKRRG3RZHU
XSKRRGFKHFNIRUOHDNVDURXQGGXFWWDSHDQGYHULI\DOO
functions.
Fig.11 Fig.12A
11) Secure (2) 1” wood screws (A) into the screw holes on
WKHOHIWDQGULJKWVLGHVRIWKH¿OWHURSHQLQJ7KLVZLOOVHFXUH
the hood body to the cabinet base and prevent the hood
from shifting after installation.
Fig.12B
3ODFHIURQWSDQHOEDFNRQKRRGERG\DQGVHFXUHLQ
place by using the (10) screws previously removed from
step 2.
13
'XFWOHVVUHFLUFXODWLRQLVLQWHQGHGIRUDSSOLFDWLRQVZKHUHDQH[KDXVWGXFWZRUNLVQRWSRVVLEOHWREHLQVWDOOHG
When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust
IURPFRRNLQJDUHGUDZQDQG¿OWHUHGE\DQRSWLRQDOFKDUFRDO¿OWHU7KHDLULVWKHQSXUL¿HGDQGUHFLUFXODWHGEDFN
within the home.
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct
ZRUNLISRVVLEOH7KHKRRGLVPRVWHႇHFWLYHDQGHႈFLHQWDVDQH[KDXVWKRRG2QO\ZKHQWKHH[KDXVWRSWLRQ
is not possible should you recourse to converting the hood into a recirculating hood.
:KHQFRQYHUWHGWREHDUHFLUFXODWLQJKRRGDFKDUFRDO¿OWHULVUHTXLUHGRQWRSRIWKHGHFRUDWLYHPHVK¿OWHU
2UGHUDFFRUGLQJWRLWVSDUWQXPEHUEHORZ7KHGHFRUDWLYHPHVK¿OWHULVLQWHQGHGWRFDSWXUHUHVLGXHIURP
FRRNLQJDQGWKHRSWLRQDOFKDUFRDO¿OWHUKHOSVWRSXULI\IXPHVH[KDXVWHGIURPFRRNLQJIRUUHFLUFXODWLRQ
RECIRCULATING KIT (REQUIRED IF NOT DUCTED OUTSIDE THE HOME)
.LWLQFOXGHVFKDUFRDO¿OWHUEUDFNHWVDQGUHWXUQDLUYHQW
Hood Model Part No. Filters in Pkg.
ZGE (all models) ZRC-00GE 1
 3XUFKDVHUHFLUFXODWLQJNLWSHUWKHSDUWQXPEHUDERYH
 5HPRYHGHFRUDWLYHPHVK¿OWHUIURPKRRGDQGSODFHFKDUFRDO¿OWHURQWRSRI
PHVK¿OWHU6HFXUHFKDUFRDO¿OWHUWRPHVK¿OWHUE\XVLQJWKHVXSSOLHGZLUH
EUDFNHWVDVVKRZQLQ)LJ
5HLQVWDOOGHFRUDWLYHPHVK¿OWHU
Charcoal Filter Replacement
Hood Model Part No. Qty to Order
ZGE (all models Z0F-C0GE 1
Installation – Ductless Recirculation
4. In order to recirculate the air properly, a return air vent must be installed to
DOORZUHF\FOHGDLUWREHUHWXUQHGWRWKHNLWFKHQ)LJ'XFWLQJPXVWEHUXQ
from the blower to the return air vent. The return air vent can be positioned
RQWRSRIWKHFDELQHWRULQDVRႈWFHLOLQJ
5. Enable Charcoal Filter Change indicator on control panel. See page 15.
 &KDUFRDO¿OWHUPXVWEHUHSODFHGDIWHUHYHU\KRXUVRIXVHRUDSSUR[LPDWHO\
HYHU\WRPRQWKVEDVHGRQDQDYHUDJHGDLO\XVHRIKRXURIFRRNLQJWLPH
The microprocessor in the controls, when set, will elapse and count usage
WLPHDQGLQGLFDWHZKHQFKDUFRDO¿OWHUUHSODFHPHQWLVUHTXLUHGHYHU\KUV
Fig.13
Fig.14
14
www.zephyronline.com
Blower On/Off
By pressing , the blower is switched On and Off. When switched On, the blower will
operate at the last setting before it was switched Off. When switched Off the entire hood
powers Off, including the lights.
Speed Selection
The 3 speed levels are selected by pressing to decrease and to increase speed
level. The display indicates speed level selected. Pressing when the hood is Off will
also switch the blower On.
Delay Off
Delay Off is used for programmed shut down of blower and lights 5 minutes after the function
is activated. Press once and a dot will appear in the lower right side of the Display
indicating the function is on. The hood will change to Speed 1 and shut down after 5 minutes.
Lights Normal/Dim/Off
Switch lights on to Normal by pressing once, again to Dim and again to switch Off.
1
2
3
4
Display
Displays blower speed level, delay off status, mesh filter clean and charcoal filter replace notification.
5
Lights Normal/Dim/Off
5 Min Delay Off
Display (speed level, delay of
f, filter clean/replace)
Speed Selection
Blower On/Off
NOTE: Blower and lights will automatically shut off when the glass is closed. The hood
also has a built in memory function that will automatically turn the blower and
lights on at the last setting when the glass is pulled open.
Blower will not operate while the glass is closed but the lights will still function.
The decorative mesh filter is required to be cleaned frequently and as recommended in
order to maintain blower efficiency. If improperly maintained, residue from cooking will
sift through filter and cause damage to hood blower and other sensitive components by
possibly clogging duct work and creating a fire hazard.
Features & Controls – Touch Controls
15
Decorative Mesh Filter Clean Reminder (metal mesh filter)
Whether your hood is installed as an exhaust or purifying unit, a decorative mesh filter is fitted by the factory. This
mesh filter is intended to filter out residue from cooking. It need not be replaced on a regular basis but is required to
be kept clean. After every 30 hours of use the Filter Clean Reminder function in the microprocessor will automati-
cally remind you by a flashing when the mesh filter needs to be cleaned. The filter can be cleaned by hand
with non-abrasive soap or in a dishwasher. A heavily soiled filter should also be soaked in grease cutting
detergent prior to cleaning.
Decorative Mesh Filter Clean Indicator
When flashes on display, the mesh filter installed is
required to be cleaned. This will occur after every 30
hours of use.
Re-setting Function
Reset the filter clean reminder timer when filter is cleaned
and re-installed. With hood off, press and hold for
approximately 5 seconds until on display disappears
. . The filter clean reminder function is now reset
and a new 30 hours elapse cycle is initiated.
F
Clean Filters
display < F > flashes
F
hold 5 sec. display from < F > to < >
To Reset
F
F
F
Charcoal Filter Replace Reminder (charcoal filter, if installed)
When your hood is installed as a recirculating unit it must be fitted with a charcoal filter to purify exhaust and fumes
from cooking and then recirculate the air within the home. This charcoal filter must be replaced after every 120 hours
of use. The charcoal filter should never be cleaned or placed in a dish washer.
The charcoal filter replace reminder function in the microprocessor needs to be switched on. When switched on, the
microprocessor will elapse and count usage time. When charcoal filter replacement is needed a flashing will
appear on the display.
C
Setting the Charcoal Filter Replace Reminder
With hood off, hold for approximately 5 seconds.
The display will change from (exhaust mode) to
(recirculating mode). This indicates that the elapse
timer function is switched on and charcoal filter is being
used.
Charcoal Filter Replace Indicator
When the display starts flashing, the charcoal filter
needs to be replaced. Purchase replacement charcoal
filters from Zephyr.
Re-setting Function
After charcoal filter is replaced, with hood off, press and
hold for apprimately 5 seconds until on the
display disappears . The filter change reminder is
now re-set and a new 120 hour elapse cycle is initiated.
C
C
C
C
hold 5 sec. display from < - > to < C >
Set Mode
Set Mode
display < C > flashes
Change FIlter
C
hold 5 sec. display from < C > to < >
To Reset
C
Features & Controls – Filter Clean and Replace Reminder
16
www.zephyronline.com
Features & Controls – Remote Control (Optional)
FCC Caution:7RDVVXUHFRQWLQXHGFRPSOLDQFHDQ\FKDQJHVRUPRGL¿FDWLRQVQRWH[SUHVVO\DSSURYHGE\WKHSDUW\
responsible for compliance could void the user’s authority to operate this equipment. This device complies with Part
15 of the FCC Rules. Operation is subject to the following two conditions. (1) This device may not cause harmful
interference, and (2) This device must accept any interference received, including interference that may cause
undesired operation.
Remote control is sold as an optional accessory. Purchase Zephyr part number: 14000005
This remote control may operate in humid environments, but not when placed on a wet surface.
Blower On / Speed Selection
Press to power on blower and cycle through all six blower speeds.
Blower On / Power Off
By pressing , the blowers will power on at the last speed setting. Press
again and the entire hood will power off, including lights.
Delay Off
Lights On / Dim / Off
Switch lights On by pressing once, again to dim and again to switch Off.
Blower On/
Speed Selection
1
1
2
3
4
Blower On/
Power Off
2
5 Min Delay Off
3
Lights On/Dim/Off
4
By pressing , the blower and lights will enter Delay Off mode. A dot will
appear in the lower right corner of the hood display indicating the function
is on. The blower will change to speed 1 and shut down after 5 minutes.
A
-
+
SYNCHRONIZATION: 7RFUHDWHDXQLTXHOLQNEHWZHHQ\RXUUDQJHKRRGDQGUHPRWHFRQWUROSOHDVHIROORZWKHEHORZVWHSV
:LWKUDQJHKRRGRႇSUHVVDQGKROGWKH³OLJKWV´EXWWRQRQWKHUDQJHKRRGXQWLOWKHOHWWHU³)´VKRZVRQWKHGLVSOD\VFUHHQ 
3UHVVWKH³OLJKWV´EXWWRQRQWKHUHPRWHWKHOLJKWVRQWKHKRRGZLOOWXUQRQ7KHV\QFKURQL]DWLRQLVFRPSOHWH
REMOTE CONTROL FEATURES:
The RF remote control is equipped with a magnet for easy storage. The remote may be placed on any magnetic surface such
DVDUHIULJHUDWRURUWKH=HSK\UUHPRWHKROGHU0D[LPXPUHPRWHFRQWUROFRPPXQLFDWLRQGLVWDQFHIURPSRZHUSDFNLVIHHW
REMOTE CONTROL MAINTENANCE:
Clean the remote control using non abrasive detergents
Follow instructions below for replacing battery.
8VLQJDVPDOOÀDWKHDGVFUHZGULYHUUDLVHWKHFRYHURIWKHEDWWHU\GRRUA)
in order to access the battery compartment.
Remove the battery and replace with Type A23 12V.
Negative end of battery should face the spring inside the remote.
Replace battery door and recycle old battery.
17
SURFACE MAINTENANCE:
Do not use corrosive detergents, abrasive detergents or oven cleaners.
Do not use any product containing chlorine bleach or any product containing chloride.
Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface.
Cleaning Stainless Steel
&OHDQSHULRGLFDOO\ZLWKZDUPVRDS\ZDWHUDQGFOHDQFRWWRQFORWKRUPLFUR¿EHUFORWK$OZD\VUXELQWKH
direction of the stainless steel grain. To remove heavier grease build up use a liquid degreaser detergent.
$IWHUFOHDQLQJXVHDQRQDEUDVLYHVWDLQOHVVVWHHOSROLVKFOHDQHUVWRSROLVKDQGEXႇRXWWKHVWDLQOHVVOXVWHU
DQGJUDLQ$OZD\VVFUXEOLJKWO\ZLWKFOHDQFRWWRQFORWKRUPLFUR¿EHUFORWKDQGEXႇLQWKHGLUHFWLRQRIWKH
stainless steel grain.
Aluminum Mesh Filters
7KHDOXPLQXPPHVK¿OWHUVLQVWDOOHGE\WKHIDFWRU\DUHLQWHQGHGWR¿OWHURXWUHVLGXHDQGJUHDVHIURPFRRNLQJ
7KH\QHHGQRWEHUHSODFHGRQDUHJXODUEDVLVEXWDUHUHTXLUHGWREHNHSWFOHDQ
5HPRYHDQGFOHDQE\KDQGRULQGLVKZDVKHUXVLQJDQRQSKRVSKDWHGHWHUJHQW'LVFRORUDWLRQRIWKH¿OWHU
PD\RFFXULIXVLQJSKRVSKDWHGHWHUJHQWVRUDVDUHVXOWRIORFDOZDWHUFRQGLWLRQVEXWWKLVZLOOQRWDႇHFW¿OWHU
performance. This discoloration is not covered by the warranty. Spray degreasing detergent and leave to
VRDNLIKHDYLO\VRLOHG
'U\¿OWHUVDQGUHLQVWDOOEHIRUHXVLQJKRRG
Replacing Mesh Filter
6KRXOG¿OWHUZHDURXWGXHWRDJHDQG
prolonged use, replace with the following part
number:
Hood Model: Part No. Qty. to Order.
All ZGE Models 50200036 1
5HSODFHDQ\GDPDJHG¿OWHUWKDWKDVSXQFWXUHG
RUEURNHQPHVKRUGDPDJHGIUDPH
7RUHPRYHGHFRUDWLYHPHVK¿OWHU
1. Pull down on handle.
7LOW¿OWHUGRZQDQGUHPRYHIURPKRRG
2
1
Maintenance – Hood and Filter Cleaning
18
www.zephyronline.com
REPLACING LIGHT BULBS
CAUTION: Light bulb becomes extremely hot when turned on.
'2127WRXFKEXOEXQWLOVZLWFKHGRႇDQGFRROHG7RXFKLQJKRWEXOEVFRXOGFDXVHVHULRXVEXUQV
0DNHVXUHDOOSRZHULVWXUQHGRႇDQGEXOEVDUHQRWKRW
5HPRYHE\WXUQLQJEXOEFRXQWHUFORFNZLVH1RWH%XOEGRHVQRWXQVFUHZLWWXUQVGHJUHHV
stops and falls out.
,IEXOEVDUHGLႈFXOWWRWXUQGXHWRSURORQJHGXVH¿UPO\DWWDFKDJODVVVXFWLRQFXSDSSUR[LPDWHO\WKHGLDPHWHURI
WKHEXOERUXVHDUXEEHUODWH[JORYHWRJULSWKHEXOEDQGWXUQFRXQWHUFORFNZLVH
Replacement bulbs are available the Zephyr parts store. Turn to page 21 for ordering information.
Maintenance – Lights
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51

Zephyr ZGE-E30AS Manuel utilisateur

Catégorie
Hottes
Taper
Manuel utilisateur

dans d''autres langues