Kathrein MSK 25 Manuel utilisateur

Catégorie
Haut-parleurs de la barre de son
Taper
Manuel utilisateur
Instruction Manual
MSK 25
Satellite/TV/FM
Test Receiver
analogue/digital
Preface
2
Preface
Dear customer,
The KATHREIN-Werke KG has done its utmost to guarantee the
correctness and completeness of this manual. However, no liability can
be assumed for any potential errors in this manual and any damages
thereby resulting.
This manual may not be copied or else be duplicated, neither as a whole,
nor in extracts, without the written consent of the KATHREIN-Werke KG.
This manual is subject to modifications and amendments without prior
notice. This in particular applies to modifications which suit the technical
progress.
All product names and trademarks in this manual are the property of the
respective firms.
All rights reserved.
Validity: This manual applies for the MSK 25. Date of issue: Sept. 2005
.
Contents
3
Contents
Preface.............................................................................................................................................................. 2
Contents ........................................................................................................................................................... 3
General Information......................................................................................................................................... 5
Signs and Symbols ........................................................................................................................................ 5
Safety Rules................................................................................................................................................... 5
Functionality .................................................................................................................................................... 6
Overview of Functions .................................................................................................................................... 7
Technical Data ................................................................................................................................................. 9
Control Elements and Indicators ................................................................................................................. 11
Control Elements.......................................................................................................................................... 11
TFT Colour Screen................................................................................................................................... 11
Connections (right hand side) ...................................................................................................................... 11
Short Cut Overview ....................................................................................................................................... 12
Connections ................................................................................................................................................... 13
RF Input Socket ........................................................................................................................................... 13
External DC Voltage Supply ........................................................................................................................ 13
Scart Output ................................................................................................................................................. 13
RS 232 Interface .......................................................................................................................................... 13
Commissioning.............................................................................................................................................. 14
Switching-Up ................................................................................................................................................ 14
Switching-Off................................................................................................................................................ 14
Setup-Menu.................................................................................................................................................. 15
Factory Setting on Delivery ...................................................................................................................... 15
Setup Menu Setting.................................................................................................................................. 15
Setup Menu Call-Up ............................................................................................................................. 15
Mains Operation and Battery Operation ...................................................................................................... 16
Mains Operation ....................................................................................................................................... 16
Battery Operation ..................................................................................................................................... 16
SAT measurement ......................................................................................................................................... 17
Standard Change-Over................................................................................................................................ 17
Frequency Display and Frequency Entry..................................................................................................... 18
SAT Menu Frequency Entry ..................................................................................................................... 18
SAT Analogue Level Measurement ............................................................................................................. 19
Level Overflow and Level Underflow........................................................................................................ 19
SAT DVB-S Level Measurement ................................................................................................................. 19
Locating Satellites ........................................................................................................................................ 20
Bearing for Individual Reception Frequencies ............................................................................................. 21
SAT Analogue Sound Carrier Frequency .................................................................................................... 22
DVB-S MER, BER and Offset Measurement............................................................................................... 23
MPEG Picture Representation (option) in DVB-S........................................................................................ 23
LNB Voltage and 22 kHz/60 Hz Change-Over ............................................................................................ 24
DiSEqC™ (Digital Satellite Equipment Control) .......................................................................................... 26
Framing Byte Menu .................................................................................................................................. 27
Address Byte Menu .................................................................................................................................. 28
Command Byte Menu............................................................................................................................... 29
Data Byte Menu........................................................................................................................................ 31
Simple Tone Burst DiSEqC™ ...................................................................................................................... 31
TV measurement............................................................................................................................................ 32
Standard Change-Over................................................................................................................................ 32
DVB-C/DVB-T Change-Over ....................................................................................................................... 33
Channel display and channel entry.............................................................................................................. 34
Frequency Display and Frequency Entry..................................................................................................... 35
Level Measurement TV Analogue................................................................................................................ 36
Level Overflow and Level Underflow........................................................................................................ 36
TV/DVB-C/DVB-T Level Measurement........................................................................................................ 36
Bearing for Individual Reception Frequencies ............................................................................................. 37
Sound Carrier Distance and Sound Carrier Level ....................................................................................... 38
NICAM Sound Bit Error Rate Measurement ................................................................................................ 39
DVB-C/DVB-T (option), MER, BER and Offset Measurement..................................................................... 40
Contents
4
MPEG Picture Representation (option) in DVB-C or DVB-T (option) .......................................................... 40
FM measurement ........................................................................................................................................... 41
Frequency Indication and Frequency Entry ................................................................................................. 41
Level Measurement...................................................................................................................................... 42
Level Overflow and Level Underflow........................................................................................................ 42
Bearing for Individual Reception Frequencies ............................................................................................. 43
Spectrum Measurement................................................................................................................................ 44
SAT Spectrum.............................................................................................................................................. 44
TV Spectrum ................................................................................................................................................ 44
FM Spectrum................................................................................................................................................ 45
Maintenance ................................................................................................................................................... 46
Changing the Battery ................................................................................................................................... 46
Customer Service ..................................................................................................................................... 46
Technical Appendix....................................................................................................................................... 47
Signal-to-Noise-Ratio................................................................................................................................... 47
DiSEqC™ Commands for Kathrein Matrices............................................................................................... 48
Instruction Set for 9xx Kathrein Matrix Production Run ........................................................................... 48
Instruction Set for EXR 20 Kathrein Matrix .............................................................................................. 48
Instruction Set for EXR 22 Kathrein Matrix .............................................................................................. 48
Channel Tables ............................................................................................................................................ 49
Channel Table and Frequency Table B/G Standard (frequencies in MHz).............................................. 49
Channel Table and Frequency Table L Standard (frequencies in MHz).................................................. 50
Channel Table and Frequency Table D/K Standard (frequencies in MHz).............................................. 51
Channel Table and Frequency Table I Standard (frequencies in MHz)................................................... 52
Channel Table and Frequency Table M1 Standard (Japan) (frequencies in MHz) ................................. 53
Channel Table and Frequency Table M/N Standard (frequencies in MHz) ............................................. 54
Channel Table and Frequency Table M/N Standard (frequencies in MHz) ............................................. 55
General Information
5
General Information
This user manual has been compiled for persons with some electrical
engineering ability and knowledge. Users who have already operated
similar measuring instruments can obtain the necessary commands for
each operating step from the overview. In addition, the following
examples will help you understand each operating step.
Signs and Symbols
Always adhere to the instructions classified with the warning signal
carefully, as otherwise the MSK 25 test receiver may be damaged or
even be destroyed.
This symbol provides information on measuring functions and refers to
chapters containing further particulars on a subject.
This symbol is followed by an example of the measuring function
explained.
Find an overview of the commands for the germane short cut for the
particular measuring function.
Key on the instrument to be pressed.
Safety Rules
Careful observance of the VDE safety instructions is essential!
Only fuses with the same power-down characteristics are to be used!
On feeding in signals, heed the allowable peak levels!
• HF input: max. 120 dBµV (60 dBmV)!
• Do not connect direct-current (DC) voltage to the RF socket!
Do not connect low frequency alternating-current (AC) voltage to the RF
socket!
The instrument is also energised when disconnected!
Use only the power supply unit provided for voltage feed!
Depending on the programming, between 5 V and 20 V may be
connected to the RF input socket. From 10 V to 20 V, up to 500 mA can
be obtained from the source, and up to 100 mA can be obtained from 5 V
to 9.9 V.
Additionally included in Delivery
1 Wall power supply
1 BNC measuring cable
1 Adapter BNC socket – F socket
1 Adapter BNC socket – F plug
1 Adapter BNC socket – IEC socket
1 Adapter BNC socket – IEC plug
1 20 dB attenuation plug with d.c. voltage passage
(Find indications on the frequency response of the enclosed attenuation
plug on the last page)
Electronic equipment is not household waste - in accordance with
directive 2002/96/EC OF THE EUROPEAN PARLIAMENT AND THE
COUNCIL of 27th January 2003 on used electrical and electronic
equipment, it must be disposed of properly.
At the end of its service life, take this unit for disposal at a relevant
of. cial collection point.
À
[
ke
y
]
Functionality
The MSK 25 has been conceived as a portable test receiver for TV, SAT
and FM radio measurements, as well as for DVB-C, DVB-S and DVB-T in
both, battery operation and mains operation. The built-in lead battery (3.4
Ah) and a wall power supply with a built-in charger, suitable for 230 VAC,
are included in delivery.
Controlling and scanning of the console and the display of frequency and
level on the LCD are carried out by a microcontroller. The receiving
frequency is indicated in MHz. Levels are measured with a peak value
detector or with an average value detector and indicated digitally in dBµV
or dBmV. Correction values are determined when the levels are
calibrated for the MSK 25 and stored in EEPROM. Thus, precise level
measurement readings can be recorded.
A bargraph display is provided to help locate transmitters. In addition, a
level-dependent acoustic signal facilitates the antenna alignment. The
display need not be observed.
The audio part with its built-in loudspeaker can process and reproduce
the various Sat and TV-NF signals complying with the B/G, D/K, I, M1
(JAPAN) and M/N standards, as well as with the FM audio signals and
the DVB-C-, DVB-T- and DVB-S signals (if the intrument provides MPEG
or DVB-T respectively). NICAM and AM sound reproduction (L standard)
is also possible.
The LNB supply voltage of 20 V /, max. 500 mA, with a graduation of 0.1
V, as well as the superimposition of 22 kHz / 60 Hz and the option to
send DiSEqC™ commands or Simple-DiSEqC™commands, cover all
currently known specifications. In DVB-T mode, you can obtain antenna
feed voltage between 5 V and 9.9 V, max. 100 mA, from the RF socket.
The built-in TFT colour screen allows the screening and evaluation of
analogue TV and SAT signals on the spot. If MPEG option is provided,
also digital signals can be displayed.
Overview of Functions
7
Overview of Functions
Function
Analogue
SAT mode
Analogue
TV mode
Analogue
FM mode
DVB-S mode
DVB-C mode
Option DVB-T
mode
Mains operation and battery operation
*
*
*
*
*
*
Level measurement by frequency setting
*
*
*
*
*
*
Level measurement by channel setting
*
*
*
Level-dependent acoustic signal
*
*
*
*
*
*
Spectrum display
*
*
*
*
*
*
Loudspeaker for acoustics control
*
*
*
Option MPEG
Option MPEG
Option MPEG
Multiple standards reception (B/G, D/K, I, L, Nicam,
M/N, M1)
Nicam audio reception and L standard
*
*
*
QPSK
QAM 64,
QAM 128
COFDM
2k, 8k
Sound storage medium setting
*
*
Sound storage medium measurement
*
LNB external feeding power supply tunable
LNB external feeding current measurement
*
*
*
*
*
*
22 kHz / 60 Hz change-over
*
*
*
*
DiSEqC™, Simple DiSEqC™
*
*
*
*
*
*
DVB level measurement
*
*
*
DVB-MER-BER measurement
*
*
*
DVB displaying
Option MPEG
Option MPEG
Option MPEG
Scart output (video and audio)
*
*
* (audio )
Option MPEG
Option MPEG
Option MPEG
Nicam tone, reception and bit error rate measurement
*
8
LNB
0/5 - 20 V
Technical Data
9
Technical Data
Power supply
Mains operation 230 VAC, 50/60 Hz
Battery operation Lead Battery 12 V/3.4 Ah
Dimensions Width 260 mm, Height 90 (120) mm, Depth 165 mm
incl. accessories (plus case)
Weight ca. 4.5 kg (incl. case)
Safety standards CE mark
Protection class II
VDE EN 61010
Display TFT screen, LCD alpha numeric, 2x16 characters, Bargraph
display, backlit
Temperature range +5 C to +45 C
Frequency range SAT 920 MHz...2150 MHz
TV 48 MHz...858 MHz
FM 88 MHz...108 MHz (48 MHz...858 MHz)
Channel configuration TV B standard 7 MHz
D/G/I/K standard 8 MHz
M/N/M1 standard 6 MHz
Frequency tuning SAT 0.125 MHz graduations
TV 50 kHz graduations
FM 50 kHz graduations
Measurement error SAT Max. ±2 dB
TV/FM Max. ±2 dB
RF input BNC 75 coaxial socket
RF input reducer 0 – 60 dB in 4 dB graduations
Level measurement range 30–120 dBµV
Measurement bandwidth SAT 6 MHz
SAT DVB 6 MHz
TV 250 kHz TV/DVB 6 MHz
FM 250 kHz
Measuring detector SAT Average value display
TV Maximum value display
FM Average value display
Voltage standing wave ratio > 6 dB
FM threshold SAT < 9 dB
Audio-IF bandwidth SAT 230 kHz/150 kHz
TV 230 kHz
FM 230 kHz
Audio Deemphasis SAT 50 µs
TV/FM 50 µs
Audio processing SAT FM audio processing 5.0 MHz…8.99 MHz in 10-kHz graduations
TV FM and Nicam in quasi-parallel audio mode
AM in parallel audio mode (L standard only)
Technical Data
10
TV B/G standard TT1 = 5.5 MHz, TT2 = 5.74 MHz
D/K standard TT1 = 6.5 MHz, TT2 = 6.26 MHz
I standard TT1 = 6.0 MHz
M/N standard TT1 = 4.5 MHz, TT2 = 4.72 MHz
M1 standard TT1 = 4.5 MHz
L standard AM 6.5 MHz, Nicam = 5.85 MHz
B/G standard Nicam = 5.85 MHz
I standard Nicam = 6.552 MHz
FM FM audio processing 48 MHz...858 MHz
Sound carrier measurement TV Standard B/G 5.5 MHz, 5.74 MHz,
5.85 MHz
D/K standard 6.5 MHz, 6.26 MHz
I standard 6.0 MHz, 6.552 MHz
L standard 6.5 MHz, 5.85 MHz
M/N standard 4.5 MHz, 4.72 MHz
M1 standard 4.5 MHz
Nicam decoder
Sound carrier distance TV 5.58 MHz with B/G, D/K, L standards
6.552 MHz with I standard
Nicam BER TV 0-4 x 10
-2
DVB-S modulation method
1)
QPSK
DVB-C modulation method
1)
64 QAM, 128 QAM, DOCSIS 64 QAM (MER and Offset only)
DVB-T modulation method
1)
OFDM, 2k, 8k, QPSK, 16 QAM, 64 QAM (Option)
DVB-S-MER
1)
-20 dB
DVB-C-MER
1)
-32 dB
DVB-T-MER
1)
-32 dB (Option)
DVB-S-BER pre-Viterbi
1)
0 – 2.8 x 10
-2
DVB-C-BER pre-Reed Solomon
1)
0 – 2.8 x 10
-2
DVB-T-BER pre-Viterbi
1)
0 – 2.8 x 10
-2
(Option)
DVB-S carrier-offset-measurement
1)
DVB-C carrier-offset-measurement
1)
DVB-T carrier-offset-measurement
1)
(Option)
LNB supply voltage SAT 0, 10 V...20 V, max. 500 mA
External feeding voltage TV 0, 5 V...9.9 V, max. 100 mA
LNB control SAT 22 kHz, 60 Hz, DiSEqC™, Simple DiSEqC™
SCART output 1 V
pp
/75 Ohm
1) For measuremts exceeding 100 dBµV please use the enclosed attenuation plug, as otherwise no video representation and no MER
and BER measurements are possible.
Control Elements and Indicators
11
Control Elements and Indicators
Control Elements
The following is displayed on the two-row 16 digit LC display, depending
on the mode:
the channel set,
the frequency set,
the function called up,
the mode,
the measured level
the measured value
TFT Colour Screen
The colour screen has a diagonal of 4“, a resolution of 238 x 480 pixel,
and a luminance of 250 cd/m².
Connections (right hand side)
(AV) Scart connections without inputs, RS 232 interface,,
supply voltage DC – for the power supply unit delivered only
FR: 954.0 MHz SAT
LEV: 40.0 dBuV D
TFT colour screen LC display HF input socket LED volume control Keyboard
Short Cut Overview
12
Short Cut Overview
Key Brief description of the various functions
SAT/DVB-S TV/DVB-C/*DVB-T FM
SAT/TV
Change-over to
TV reception
Change-over
SAT reception
Change-over to
TV reception
- Diminish current values
+ Elevate current values
0-9 Numeric character entry
./S Decimal point for
numeric character entry
Decimal point for
numeric character input
Special channel call up
Decimal point for
numeric character input
ENTER Confirm numeric character entry
2ndF + key Call-up of the second command level
FM Change-over to FM
Sat-Ctrl Call-up of DiSEqC™ menu /
LNB
Menu / Remote feeding Call-up of DiSEqC™
menu / remote feeding
LNB LNB voltage menu and
current measurement
Remote feeding voltage and
current measurement
Remote feeding voltage
and current
measurement
Ch-Freq
No function
Call-up of frequency
menu
Change-over from
channel display to
frequency display and
reverse
No function
Std DVB-S/analogue change--
over
DVB-C/*DVB-T/analogue-
change-over
standard-change-over
No function
DVB
DVB-S measurement
MER, BER, OFFSET
*MPEG programme
selection
DVB-C-/*DVB-T
measurement
MER, BER, OFFSET
*MPEG programme
selection
No
SC (Subcarrier) sound carrier menu, sound carrier measurement No function
Scan Frequency-independent
satellite search
No function No function
Level Switch-on level-dependent acoustic signal with bargraph display
Spect Spectrum analysis
Setup Adjustment of instrument settings
* only if option is provided
Connections
13
Connections
RF Input Socket
The received signal of the antenna or of the cable network is fed in here
(BNC coaxial socket).
The remote feeding voltage (for LNB) is adjustable from 5 V
DC
to 20 V
DC
and can be switched off. When the LNB voltage is switched on, the LED
next to the RF input socket flashes.
Make sure that there are
no voltage level over 120 dBµV,
no positive DC voltage over 22 V
DC
,
no negative DC voltage and
no AC voltage
adjacent to the RF input socket.
Non-compliance with these warning notices may destroy the input circuit.
External DC Voltage Supply
The MSK 25 may either be mains operated or battery operated (batteries
built-in). The external voltage supply is carried out via the DC socket at
the right side of the MSK 25 box, with the wall power supply and the
charger, both included in delivery. Sustained continuous operation (incl.
MPEG option) is possible in case of an LNB power consumption of no
more than max. 300 mA. Additional current will be drained from the
battery built-in if the power consumption is higher than that.
Make sure that
only the wall power supply included in delivery is used.
the wall power supply is not connected to the instrument but for
voltage feed. Otherwise the battery of the MSK 25 will be discharged!
Scart Output
The video and audio signals are emitted on the Scart socket on the right
hand side of the MSK 25, for rating purposes on an external monitor.
There are no inputs!
Misallocations of the connections may cause damage or destruction
of the instrument!
RS 232 Interface
Software updates are possible via RS 232 interface.
Commissioning
14
Commissioning
Switching-Up
Connect the instrument to the mains with the wall power supply.
Turn the on/off switch to the right.
Adjust the desired volume.
The LC display will then indicate the particular software version for appr.
1 second.
Thereafter the LC display will indicate the loading capacity of the battery
for appr. 3 seconds.
One segment comes up to appr. 20% of the overall capacity (3.4 Ah).
Now, feed in the reception signal of the receiving installation in the RF
input socket.
LC display:
channel
mode
level (A = analogue level measurement; D = digital level
measurement)
Select the desired mode by pressing [TV/SAT]
Switching-Off
Turn the on/off switch counter-clockwise.
Software V2.0
SN: 000222
ACCU [−−−−−]
CH: .02. TV
LEV: 48.5dBuV A
Commissioning
15
Setup-Menu
The basic setting (status of the MSK 25 after switching it on) can be set in
the Setup menu.
Factory Setting on Delivery
Parameter Setting
POWER ON TV
LNB DC OFF
LEVEL dBµV
Low Level Mute ON
Setup Menu Setting
Setup Menu Call-Up
Press [2ndF] and [SETUP].
The particular mode (TV, SAT, FM) is selected and taken-over by
pressing either [1], [2] or [3]. The current setting is retained by pressing
[ENTER.]
1. Setup menu
The following requests appear:
Press either [1] or [2] to switch on/off the LNB voltage supply.
Press [ENTER] to retain the current setting.
2. Setup menu
Press either [1] or [2] to determine the measurement unit the level is to
be displayed with.
Press [ENTER] to retain the current setting.
3. Setup menu
Set or offset the mute function by pressing either [1] or [2]. Select „ON“ to
mute the MSK 25 until the input signal on the RF input exceeds
30 dBµV.
4. Setup menu
Press [ENTER] to retain the desired setting.
Unless the factory settings have been changed, the indication opposite is
displayed.
Basic setting
After setting the Low Level Mute, the 4th Setup menu will be exitted
automatically and the basic setting will be displayed.
POWER ON
1=TV 2=SAT 3=FM
LNB DC
1=OFF 2=ON
Level
1=dBµV 2=dBmV
LOW LEVEL MUTE
1=OFF 2=ON
CH: .07. TV
LEV:____.__dBµV
Commissioning
16
Mains Operation and Battery Operation
The MSK 25 may either be mains operated or be battery operated
(battery built-in).
Mains Operation
Only the wall power supply delivered may be used for power supply.
Connect it to the voltage supply socket on the right hand side of the
instrument.
Sustained continuous operation (incl. MPEG option) is possible in case of
an LNB power consumption of no more than max. 300 mA. Additional
current will be drained from the battery built-in if the power consumption
is higher than that.
In case of any longer-lasting placing-out-of-operation, connect the MSK
25 to the mains supply occasionally (trickle charge).
Make sure that the wall power supply is not connected to the instrument
but for voltage feed. Otherwise the battery of the MSK 25 will be
discharged!
Battery Operation
Battery operation is only possible if the battery is sufficiently charged.
Otherwise the MSK 25 cannot be switched on.
When completely discharged, the battery must immediately be
recharged, since otherwise it may be damaged or destroyed.
Charging begins automatically as soon as the instrument has been
connected to the mains supply. Battery supercharge is avoided with a
protective circuit.
When switching on the MSK 25, the loading capacity of the battery is
indicated for appr. 3 seconds.
The maximum operating time with a fully charged battery is appr. 2.5 hrs,
in case of an LNB supply current of 150 mA.
SAT measurement
17
SAT measurement
Standard Change-Over
In SAT mode, the MSK 25 receives
analogue signals and
DVB-S signals.
SAT Menu Standard Change-Over
[2ndF] [STD] calling up menu standard change-over:
[1] to [2] select standard
1 = analogue
2 = digital (DVB-S)
Examples
Calling up DVB-S standard
Press [2ndF] [STD]
The LC display indicates the following options:
1 = analogue standard
2 = digital (DVB-S) standard
When selecting ‚2‘ you will get to the symbol-rate-selection
The LC display indicates the following options:
Under the position 4=USER you can enter sample rates from 1,500 up to
32,000 ks and close with ENTER.
Standard menu
When you have selected an option, you will leave the standard menu and
the instrument will be set to DVB measurement.
The display indicates ‘D’.
Display for DVB-S measurement
1=ANALOGUE
2=DVBS
FR:1288.0MHz SAT
LEV: 66.5dBuV D
À
1=27500 2=24500
3=22000 4= USER
SAT measurement
18
Frequency Display and Frequency Entry
To measure the level of a received signal, you must first enter the
frequency required. The LC display indicates the frequency and the level
measured. Frequency entry is possible from 920 MHz to 2150 MHz in
100 kHz steps.
SAT Menu Frequency Entry
[SAT/TV] Changing over to SAT reception
[0] to [9] Entering frequency
[+] [-] Varying frequency in 100 kHz steps
[ENTER] Confirming your entry
LC display:
Frequency: 1288 MHz
Mode: SAT
Level: 66.5 dBµV A (A = analogue)
Example
Enter the frequency 1508 MHz by pressing [1] [5] [0] [8] [ENTER]
LC display:
frequency: 1508 MHz
mode: SAT
level: 86.5 dBµV (A = analogue)
The indicaton „+“ or „–“ on the display means that the MSK 25 has not
been exactly tuned to the carrier required. Bei pressing either [+] or [-],
the frequency can be finetuned for optimum reception. This has been
achieved when a vertical line appears on the display.
Note
Press [ENTER] to complete the frequency entry.
The last frequency entry will be retained even after you have switched off
the MSK25, provided that the entry was carried out via numeric character
input ending with ‚MHz‘
FR:1288.0MHz SAT
LEV: 66.5dBuV A
FR:1508.0MHz SAT
LEV: 86.5dBuV A
À
SAT measurement
19
SAT Analogue Level Measurement
Once you have entered a frequency, the level is measured automatically
and displayed either in dBµV or dBmV (depending on the basic
configuration) on the LC display. The input level can be measured in the
range of 30 dBµV to 120 dBµV (-30 dBmV to 60 dBmV).
LC display:
Frequency: 1508 MHz
Mode: SAT
Level measured: 86.5 dBµV A
Level Overflow and Level Underflow
The LC display indicates underflow at a level of < 30 dBµV.
The following indications appear on the display:
frequency: 1508 MHz
mode: SAT
level: underflow
The LC display indicates overflow at a level of > 120 dBµV.
The following indications appear on the display:
frequency: 1508 MHz
mode: SAT
level: overflow
Note
DVB-S signal levels can only be measured when the digital reception is
set.
SAT DVB-S Level Measurement
LC display when the DVB-S level is measured:
The change-over from the analogue measurement to the digital level
measurement is described in chapter ‚standard change-over‘
Frequency 1236 MHz
Mode: SAT DVB-S
Level measured: 86.5 dBµV D
FR:1508.0MHz SAT
LEV: 86.5dBuV A
FR:1508.0MHz SAT
LEV: __._dBuV A
FR:1508.0MHz SAT
LEV: ¯¯˙¯dBuV A
FR:1236.0MHz SAT
LEV: 86.5dBuV D
SAT measurement
20
Locating Satellites
With the SCAN function, satellites, the exact transponder frequencies of
which are unknown, can be located. In doing so, the frequency range
from 1000 MHz to 2100 MHz is continuously scanned for received
signals. If signals are received, the reception level is displayed as a bar
graph. The measurement range may be adjusted to three different
sensitivity levels.
The level can be monitored with an acoustic signal, the pitch of which is
proportional to the received-signal level. The volume of the acoustic
signal can be adjusted with the volume regulator.
SCAN Menu
[2ndF] [SCAN] Changing over to SCAN mode
[-] [+] Change-over of the bar graph measurement range.
Level range 1: high input levels
Levelrange 2: medium input levels
Level range 3: low input levels
[2ndF] [2ndF] Exit
LC display:
Level range 2: medium input level
SAT mode
Bargraph display
Example
Calling up SCAN mode:
Press [2ndF] [SCAN].
Move the antenna until there is a level tendency visible on the bargraph
display.
Move the antenna until the maximum amplitude on the bargraph display
is reached.
If necessary, diminish or elevate the sensitivity by pressing either [-] or
[+].
Exit:
Press [2ndF] twice.
LEV-Range:2 SAT
> ■■■■
À
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56

Kathrein MSK 25 Manuel utilisateur

Catégorie
Haut-parleurs de la barre de son
Taper
Manuel utilisateur

dans d''autres langues