2. Sécurité
Agréments ATEX et IECEx
Gaz et brouillard : Installation en zone 0 (EPL Ga/Gb) ; installation en zone 0 (EPL Ga) et zone 2 (EPL Gc)
Poussières : Installation en zone 20 (EPL Da/Db) ; installation en zone 20 (EPL Da) et zone 22 (EPL Dc)
Industrie minière : EPL Ma
Agréments CSA et FM
Transmetteur de pression homologué pour un usage en zone explosive, en conformité avec les certicats respectifs
(voir dessin de contrôle N° 14137236). Dessin de contrôle, voir annexe 2 “Dessin de contrôle FM, CSA”.
Certicat CSA : 70033893
Certicat FM : FM17US0003
Agréments CSA
PROCESS CONTROL EQUIPMENT - intrinsically safe, entity - for hazardous locations
IS: Class I, division 1, groups A, B, C and D; class II, groups E, F and G; class III
Canadian zone designation: Class I, zone 0; Ex ia; IIC; IP65; DIP A20
US zone designation: Class I, zone 0; AEx ia; IIC; IP65
PROCESS CONTROL EQUIPMENT - intrinsically safe and non-incendive equipment - for hazardous locations
NI: Class I, division 2, groups A, B, C and D; class II, division 2, groups F and G; class III
Canadian zone designation: Class I, zone 2; Ex nL; IIC; IP65; DIP A22
US zone designation: Class I, zone 2; AEx nL; IIC; IP65
PROCESS CONTROL EQUIPMENT - for hazardous locations
Class I, division 2, groups A, B, C and D
Canadian zone designation: Class I, zone 2; Ex nA; IIC; IP65; DIP A22
US zone designation: Class I, zone 2; AEx nA; IIC; IP65
Agréments FM
Intrinsically safe for class I, II, III division 1, groups A, B, C, D, E, F, and G hazardous (classied) locations, entity;
Intrinsically safe AEx ia for class I, zone 0, group IIC hazardous (classied) locations, entity;
Nonincendive for class I, II, III division 2, groups A, B, C, D, E, F, and G hazardous (classied) locations, NIFW;
Class I, zone 2, group IIC hazardous (classied) locations, NIFW;
Ingress protection of IP65 and a temperature class of T4, T5, and T6;
Control drawing 141137236 applies for all types of protection