AG51 (AG51-EU) Datasheet
OVERVIEW
The AG51 Unpowered Asset Tracker is a wallet-sized
tracker ideal for monitoring assets like intermodal
containers, construction equipment, dumpsters,
light towers and other mobile assets etc. It features
customizable GPS check-ins, user-replaceable AA batteries
that lasts 3 years and a waterproof and ruggedized
enclosure. The AG51 enables increased asset utilization,
theft recovery and optimized pool inventory management.
It is part of Samsara’s Connected Operations Cloud,
enabling you to capture data that helps you run your
operations more efficiently, safely, and sustainably.
CONNECTIVITY
Cellular
LTE Cat M1
Operating area: United
States, Canada, Mexico,
EU (countries with LTE-M)
Offline Storage Built-in flash memory to store
data when Internet connectivity
is unavailable
Security All Internet connectivity secured
via HTTPS with TLS encryption
Technical Specifications
LOCATION
2
GPS Advanced positioning system simultaneously reads from multiple independent
satellite systems including GPS. Internal antenna for discreet installation.
Default Check-in 2 check-ins per day
POWER
Battery 3 Energizer L91 AA batteries
Typical battery life 3 to 5 years with 2 check-ins per day. Actual battery life may
be affected by extreme temperature or cellular signal strength.
User-replaceable batteries
For questions about the safe use of AA battery powered devices, please consult
your company’s safety department
ENCLOSURE
Material UV-stabilized polycarbonate
Dimensions
110 x 81 x 31 mm
Weight 168 g
Operating Temperature
-40°C to 60°C
IP Rating IP67 (weatherproof and water resistant up to 1m submerged)
IP69K (highest grade resistance to high pressure and high temperature washdown)
Technical Specifications (cont’d)
SAMSARA CLOUD SOFTWARE FEATURES
3
Features Map-based location tracking
Approximate cell and WiFi based location
Developer APIs
Alerts
Geofence
INSTALL ACCESSORIES
What’s Included 2x Phillips screws
Regulations
4
This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions:
(1)
This device may not cause interference; and
(2)
This device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence.
L’exploitation est autorisée aux deux conditions suivantes:
(1)
l’appareil ne doit pas produire de brouillage, et
(2)
l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
This equipment complies with Innovation, Science and Economic Development Canada RF exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated to ensure a minimum of 20 cm spacing to any
person at all times.
CAN ICES-3(B)/NMB-3(B)
IC Radiation Exposure Statement:
This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. This equipment
should be installed and operated with minimum distance 20cm between the radiator and your body.
IC Déclaration d’exposition aux radiations:
Cet équipement est conforme Canada limites d’exposition aux radiations dans un environnement non contrôlé. Cet
équipement doit être installé et utilisé à distance minimum de 20cm entre le radiateur et votre corps.
Regulations (cont’d)
FEDERAL COMMUNICATION COMMISSION INTERFERENCE STATEMENT
5
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one of the following measures:
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected
Consult the dealer or an experienced radio/TV technician for help
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the
user’s authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept any interference received, including interference that may
cause undesired operation.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the
user’s authority to operate this equipment.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment
should be installed and operated with minimum distance 20cm between the radiator & your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Installation Statement:
This device requires professional installation and must be installed by a trained person.