E15 Environmental Sensor
INSTALLATION MANUAL
|E15
2 Last Revised: 7/11/2023
1919 19th St Sacramento, CA 95811
OVERVIEW
The Rhombus E15 proactively detects changes in temperature and humidity. With its long-lasting
battery, the E15 broadcasts to all nearby BLE-enabled Rhombus devices and can monitor fluctuations in
temperature and humidity in climate-controlled areas to protect valuable assets.
PACKAGE CONTENTS
Specifications
Dimensions
70x32.2x18.2mm (2.75x1.26x0.72in)
Power
2x 1.5V AAA Lithium, replaceable (2x Lithium Batteries Included)
Temperature Measurement
±0.3°C (0°C to 60 °C), ±0.5°C (-20°C to 0°C)
Humidity Measurement
±4.5% (0% - 10% RH), ±3% (10% - 90% RH), ±3.8% (90% - 95% RH)
Estimated Battery Life
5 years with typical medium-heavy use
Weather Resistance
IPX4
LED Indicators
Pulsing Green
E15 waiting to be registered
LED off
E15 registered and operating normally
Pulsing Red
Hard Reset required (remove and re-install battery)
Solid Red
Hardware Error (Contact Support)
LED
Button
Temperature and
Humidity Sensor
|E15
3 Last Revised: 7/11/2023
1919 19th St Sacramento, CA 95811
Installing the Battery
Remove the battery cover located on the
back of the E15.
Insert the included 1.5V AAA Lithium
batteries into the device and close the
battery cover.
Mounting the E15
Fix the E15 to the desired surface using
the mounting adhesives provided.
It is recommended that the E15 is
installed in direct line of sight with a BLE-
enabled Rhombus camera to reduce
connectivity issues.
WARNING: Improper installation may result in inaccurate or faulty sensor responses.
1.5V AAA
|E15
4 Last Revised: 7/11/2023
1919 19th St Sacramento, CA 95811
Installation Best Practices
To reduce the likelihood of E15 sensing errors or connectivity issues, the following points must
be followed:
Have a BLE-enabled Rhombus device in direct line of sight with the E15 to increase
signal strength.
Avoid RF-blocking obstacles: This includes mounting the E15 inside a freezer, fridge,
behind a metal door, etc.
Avoid mounting the E15 near a source of heat (e.g., on the output vent of an AC/HVAC
system, near exhaust vent, etc.).
Ensure sensor intake panel is not covered or blocked by surrounding objects.
Registration
The E15 must be awakened from sleep mode to
be registered into the rhombus console.
There are several ways to wake the device for
registration:
Press the button on the E15.
Re-Insert battery into the E15.
The E15 LED will pulse green when waiting to be
registered and will stay awake for two (2)
minutes before going back into sleep mode.
Follow the instructions on the registration page to complete product registration.
For additional information on registering the E15 into the rhombus console, please visit:
www.rhombus.com/setup/e15
HVAC vent
vent
Button
Refrigerator
vent
|E15
5 Last Revised: 7/11/2023
1919 19th St Sacramento, CA 95811
Notes
Supplemental Info
For additional information and recommendations on setting up the E15, please visit:
https://support.rhombussystems.com/hc/en-us/articles/14921970592141-Registering-the-E15
For a product overview and additional E15 sensor specifications, please visit:
https://www.rhombus.com/sensors/environmental-monitoring/e15
Support
For questions or troubleshooting support, contact Rhombus support at help@rhombus.com or submit a
request online at: https://support.rhombussystems.com/hc/en-us/requests/new
|E15
6 Last Revised: 7/11/2023
1919 19th St Sacramento, CA 95811
Notes
E15 Compliance
FCC Compliance Statement
FCC ID: 2AZ3J-B10
1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause undesired operation.
2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority
to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
RF warning statement:
To maintain compliance with FCC s RF Exposure guidelines, This equipment should be installed and operated with
minimum distance 20cm between the radiator and your body: Use only the supplied antenna.
IC Compliance Statement
This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic
Development Canada’s license-exempt RSS(s). Operation is subject to the following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired operation of the device.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority
to operate the equipment.
RF exposure statement:
The equipment complies with IC Radiation exposure limit set forth for uncontrolled environment. This equipment should be
installed and operated with minimum distance 20cm between the radiator and your body.
Cet appareil contient des émetteurs / récepteurs exemptés de licence conformes aux RSS (RSS) d'Innovation, Sciences et
Développement économique Canada. Le fonctionnement est soumis aux deux conditions suivantes:
(1) L’appareil ne doit pas produire de brouillage, et
(2) l’utiliateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible
d'en compromettre le fonctionnement
Tout changement ou modification non expressément approuvé par la partie responsable de la conformité pourrait annuler
l'autorité de l'utilisateur à utiliser l'équipement.
Déclaration d'exposition RF:
L'équipement est conforme à la limite d'exposition aux radiations de la IC établie pour un environnement non contrôlé. Cet
équipement doit être installé et utilisé avec une distance minimale de 20cm entre le radiateur et votre corps.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

RHOMBUS E15 Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues