Klein Tools CL445 Manuel utilisateur

Catégorie
Mesure, test
Taper
Manuel utilisateur
INSTRUCTION MANUAL
ENGLISH
FRANÇAIS pg. 37
ESPAÑOL pg. 19
HVAC Clamp Meter
True RMS
Measurement
Technology
DC MICROAMPS
INRUSH CURRENT
NON-CONTACT
VOLTAGE TESTING
AUTO-RANGING
TEMPERATURE
AUDIBLE CONTINUITY
5001748
750V
600V
600A
60M
Ω
2m
-148° –
1832°F
-100° –
1000°C
CL445
CAT IV
600V
HVAC Clamp Meter
True RMS
Measurement
INRUSH CURRENT
AUDIBLE CONTINUITY
HVAC Clamp Meter
AUDIBLE CONTINUITY
2
GENERAL SPECIFICATIONS
Klein Tools CL445 is an automatically ranging true root mean
square (TRMS) digital clamp meter that measures AC current and
inrush via the clamp, AC/DC voltage, DC microamps, resistance,
continuity, frequency, capacitance, and tests diodes via test leads, and
temperature via a thermocouple probe.
Environment: Indoor. DO NOT expose to moisture, rain, or snow.
Operating Altitude: 6562 ft. (2000m)
Relative Humidity: <95% non-condensing
Operating Temp: 32° to 122°F (0° to 50°C)
Storage Temp: 14° to 122°F (-10° to 50°C)
Accuracy: Values stated at 65° to 83°F (18° to 28°C)
Temp Coef cient: 0.1 × (Quoted Accuracy) per °C above 28°C
or below 18°C, corrections are required when ambient working
temp is outside of Accuracy Temp range
Dimensions: 9.24" × 3.77" × 1.59" (235 × 96 × 40 mm)
Weight: 12.58 oz (356.5 g) including batteries
Calibration: Accurate for one year
Auto Power-Off (APO): After approx. 10 minutes of inactivity
Standards: IEC/BS/EN 61010-1, 61010-2-032,
IEC/BS/EN 61326-1, 61326-2-2.
Conforms to UL STD.61010-1, 61010-2-032;
Certified to CSA STD.C22.2 NO. 61010-1,
61010-2-032.
Pollution degree: 2
Accuracy: ± (% of reading + # of least significant digits)
Safety Rating: CAT IV 600V
Class 2, Double insulation
Drop Protection: 6.6 ft. (2 m)
CAT III: Measurement category III is applicable to test and
measuring circuits connected to the distribution part of the
building’s low-voltage MAINS installation.
CAT IV: Measurement category IV is applicable to test and
measuring circuits connected at the source of the building’s low-
voltage MAINS installation.
Electromagnetic Environment: IEC EN 61326-1. This
equipment meets requirements for use in basic and controlled
electromagnetic environments like residential properties,
business premises, and light-industrial locations.
Specifications subject to change.
ENGLISH
5001748
3
ELECTRICAL SPECIFICATIONS
Function Range Resolution Accuracy
AC Voltage
(V AC)
600.0mV 0.1mV ±(1.8% + 5 digits)
6.000V 1mV ±(1.5% + 5 digits)
60.00V 10mV ±(1.2% + 5 digits)
600.0V 100mV
750V 1V ±(1.5% + 5 digits)
DC Voltage
(V DC)
600.0mV 0.1mV ±(1.0% + 8 digits)
6.000V 1mV ±(0.8% + 3 digits)
60.00V 10mV
600.0V 100mV ±(1.0% + 3 digits)
Input Impedance: 10MΩ
Frequency Range: 45 to 400Hz
Maximum Input: 750V AC RMS or 600V DC
AC Current
(A AC)
60.00A 10mA ±(2.5% + 10 digits)
600.0A 100mA ±(2.0% + 10 digits)
Frequency Range: 50 to 60Hz
DC Microamps
(µA DC) 600.0μA 0.1μA ±(1.2% + 5 digits)
Maximum Input: 750V AC RMS or 600V DC
Resistance
600.0Ω 0.1Ω ±(1.2% + 5 digits)
6.000kΩ 1Ω
±(1.2% + 3 digits)
60.00kΩ 10Ω
600.0kΩ 100Ω
6.000MΩ 1kΩ
60.00MΩ 10kΩ ±(2.0% + 5 digits)
Maximum Input: 750V AC RMS or 600V DC
4
OTHER MEASUREMENT APPLICATIONS
Maximum Input: 600V DC or 750V AC RMS
Diode Test: Approx. 1mA, open circuit voltage ~3.0V DC
Continuity Check: Audible signal <10Ω, max current 1.5mA
Sampling Frequency: 3 samples per second
Overload: "OL" indicated on display
Polarity: "-" on display indicates negative polarity
Display: 3-5/6 digit, 6000 Count LCD
ELECTRICAL SPECIFICATIONS
Function Range Resolution Accuracy
Capacitance
60.00nF 0.01nF ±(4.0% + 25 digits)
600.0nF 0.1nF
±(4.0% + 8 digits)
6.000μF 0.001μF
60.00μF 0.01μF
600.0μF 0.1μF
6.000mF 0.001mF ±(5.0% + 9 digits)
Maximum Input: 750V AC RMS or 600V DC
Temperature
°F
-148.0° to 32.0°F
0.1
°F
±(1.0% + 5.4°F )
>32.0° to 662.0°F
±(1.0% + 3.6°F )
>662° to 1832°F
1
°F
±(1.0% + 4°F)
Temperature
°C
-100.0° to 0.0°C
0.1
°C
±(1.0% + 3°C)
>0.0° to 350.0°C
±(1.0% + 2°C)
>350° to 1000°C
1
°C
±(1.0% + 2°C)
Maximum Input: 750V AC RMS or 600V DC
Frequency
(Hz)
99.99Hz 0.01Hz
±(0.1% + 5 digits)
999.9Hz 0.1Hz
9.999kHz 0.001kHz
60.00kHz 0.01kHz
Duty Cycle
0.1% to 99.9%
(≤10kHz)
0.1% ±1.5%
(Range: 10% – 90%)
Maximum Input: 750V AC RMS or 600V DC
ENGLISH
5
WARNINGS - GENERAL
To ensure safe operation and service of the meter, follow these instructions.
Failure to observe these warnings can result in severe injury or death.
Before each use verify meter operation by measuring a known voltage
or current.
Never use the meter on a circuit with voltages that exceed the category
based rating of this meter.
Do not use the meter during electrical storms or in wet weather.
Do not use the meter or test leads if they appear to be damaged.
Probe assemblies to be used for MAINS measurements shall meet IEC/EN
61010-031 with a voltage RATING of CAT IV 600V or better.
Ensure meter leads are fully seated, and keep fingers away from the
metal probe contacts when making measurements.
Use caution when working with voltages above 25V AC RMS or 60V DC.
Such voltages pose a shock hazard.
To avoid false readings that can lead to electrical shock, replace batteries
when a low battery indicator appears.
Do not attempt to measure resistance or continuity on a live circuit.
Always adhere to local and national safety codes. Use personal protective
equipment to prevent shock and arc blast injury where hazardous live
conductors are exposed.
To avoid risk of electric shock, disconnect leads from any voltage source
before removing battery door.
To avoid risk of electric shock, do not operate meter while battery door is removed.
WARNINGS - NCV FUNCTION
When NCV Function is initiated, a blinking or steady red glow and an audible
beep indicate voltage present. If no indication, voltage could still be present.
Before and after each use of the NCVT, verify operation by testing a known
working circuit that is within the rating of this unit.
Never assume neutral or ground wires are de-energized. Neutrals in multi-wire
branch circuits may be energized when disconnected and must be retested
before handling.
The NCV tester WILL NOT detect voltage if:
The wire is shielded.
The
operator is not grounded or is otherwise isolated from an effective earth ground.
The voltage is DC.
The NCV tester MAY NOT detect voltage if:
The user is not holding the tester.
The user is insulated from the tester with a glove or other materials.
The wire is partially buried or in a grounded metal conduit.
The tester is at a distance from the voltage source.
The field created by the voltage source is blocked, dampened, or otherwise
interfered with.
The frequency of the voltage is not a perfect sine wave between 50 and 60Hz.
The tester is outside of operation conditions (listed in Specifications section).
Operation may be affected by differences in socket design and insulation
thickness and type; tester may not be compatible with some types of standard
or tamper resistant (TR) electrical outlets.
Do not apply to uninsulated hazardous live conductors.
Detection above 50V is specified under “normal” conditions as specified below.
The tester may detect at a different threshold at different conditions, or may not
detect at all unless:
The
tip of the tester is within 0.25" of an AC voltage source radiating unimpeded.
The user is holding the body of the tester with his or her bare hand.
The user is standing on or connected to earth ground.
The air humidity is nominal (50% relative humidity).
The tester is held still.
6
ENGLISH
SYMBOLS ON METER
AC (Alternating Current) AC/DC Current
DC (Direct Current) Resistance (in Ohms)
Double Insulated Class II Audible Continuity
Warning or Caution Risk of Electrical Shock
Suitable for uninsulated hazardous
live conductors
Read Instructions
Diode Ground
Hz
Frequency Capacitance
%
Duty-cycle V Voltage (Volts)
°
F/
°
C
Temperature (Fahrenheit / Celsius) A Amperage (Amps)
COM Common NCV
Non-Contact Voltage Tester
Backlight SEL Select
Positive Negative
Worklight
SYMBOLS ON LCD
AC AC (Alternating Current) DC DC (Direct Current)
Negative Reading Data Hold
Auto Ranging MAX Maximum Value Hold
MIN Minimum Value Hold Audible Continuity
Low Battery
°
C
Degrees (Celsius)
°
F
Degrees (Fahrenheit)
k
kilo (value × 10
3
)
M
Mega (value × 10
6
)
μ
micro (value × 10
-6
)
m
milli (value × 10
-3
)
V
Volts (Voltage)
n
nano (value × 10
-9
) Ohms (Resistance)
A
Amps (Amperage)
F
Farads (Capacitance)
Hz%
Frequency/Duty Cycle Auto Power-Off
NCV
Non-Contact Voltage Tester Diode Test
Hazardous Voltage Indicator Inrush
7
FEATURE DETAILS
NOTE: There
are no user-
serviceable parts
inside meter.
1. 6000 count LCD display 10.
Clamp trigger
2. Function selector switch 11. Arrow markings
3. Clamp 12. "SEL/NCV" button
4. "COM" jack 13. NCV Light
5. "VΩµA" jack 14. NCV Sensing Antenna
6. Backlight/Worklight button 15. K-Type Thermocouple Inputs
7. "RANGE" button 16. Temperature/Voltage input switch
8. "MAX/MIN" button 17. "InRush" Button
9. Data Hold button 18. Worklight
19. Test Lead Holder
1
7
2
3
10
14
19
18
6
8
17
15
16
4 5
11
12
13
9
8
FUNCTION BUTTONS
ON/OFF
To power ON the meter, rotate the Function Selector switch
2
from
the OFF setting to any measurement setting. To power OFF the meter,
rotate the Function Selector switch
2
to the OFF setting. By default,
the meter will automatically power OFF after 10 minutes of inactivity. If
the meter automatically powers-OFF while in a measurement setting,
press any button to power the meter ON, or rotate Function Selector
2
switch to OFF, then power ON the meter. To deactivate the power OFF
functionality press and hold the "SELECT" button
12
before powering
ON from the OFF setting. When auto power OFF is deactivated, the Auto
Power Off icon will not be visible in the display.
SEL / NCV BUTTON (FOR NCV TESTING)
Press and hold the SEL/NCV button
12
to enter Non-contact Voltage
Testing (NCV) mode to test for presence of AC voltage. The NCV
icon and "EF" will be present on the display. Approach the conductor
under test leading with the sensing antenna
14
.
In the presence of AC
voltage, the red NCV light
13
will illuminate, audible signals (beeps)
will sound.
Release the SEL/NCV button to exit NCV testing mode.
NOTE: Only voltages of 40V AC or greater will be detected.
BACKLIGHT
Press Backlight/Worklight button
6
to turn ON or OFF the backlight.
The backlight does not automatically power OFF.
WORKLIGHT
Press and hold Backlight/Worklight button
6
for 2 seconds to turn ON
or OFF the worklight. The worklight does not automatically power OFF.
RANGE
The meter defaults to auto-ranging mode . This mode
automatically determines the most appropriate measurement range
for the testing that is being conducted. To manually force the meter
to measure in a different range, use the "RANGE" button
7
.
1. Press the "RANGE" button
7
to manually select measurement
range ( is deactivated on the LCD). Repeatedly press the
"RANGE" button
7
to cycle through the available ranges, stopping
once the desired range is reached.
2. To return to auto-ranging mode, press and hold the "RANGE"
button
7
for more than two seconds ( is reactivated).
MAX/MIN
When the "MAX/MIN" button
8
is pressed, the meter keeps track of
the Maximum and Minimum values.
1. When measuring, press "MAX/MIN" button
8
to toggle between the
Maximum value (MAX), the Minimum value (MIN). If a new maximum
or minimum occurs, the display updates with that new value.
2. Press "MAX/MIN" button
8
for more than two seconds to return
to normal measuring mode.
DATA HOLD
Press HOLD
9
to hold the measurement on the display. Press
HOLD
9
again to release the display to return to live measuring.
ENGLISH
9
OPERATING INSTRUCTIONS
CONNECTING TEST LEADS
Do not test if leads are improperly seated. Results could cause
intermittent display readings. To ensure proper connection, firmly
press leads into the input jack completely.
TESTING IN CAT III MEASUREMENT LOCATIONS
Ensure the test lead shield is pressed firmly in place. Failure to use
the CAT III / CAT IV shield increases arc-flash risk.
TESTING IN CAT II MEASUREMENT LOCATIONS
CAT III / CAT IV shields may be removed for CAT II locations. This
will allow testing on recessed conductors such as standard wall
outlets. Take care not to lose the shields.
INCORRECT
CORRECT
0.7" (18 mm)
5/32"
(4 mm)
5/32
(4 mm)
10
OPERATING INSTRUCTIONS
AC CURRENT (LESS THAN 600A)
AC Current is measured by pressing the clamp trigger
10
to open
the clamp and placing it around a current-carrying wire. When
measuring, care should be taken to ensure that the clamp is
completely closed with trigger
10
fully released, and that the wire
passes perpendicularly through the center of the clamp in line
with the arrow markings
11
.
To measure current:
1. Rotate the Function Selector switch
2
to the A~ setting.
2. Place clamp around wire. The current
measurement will be shown in the display.
Disconnect test leads when
measuring with the clamp.
ENGLISH
Red leadBlack lead
NOTE: Current measurement can be made by clamping around single
conductors, but not cables containing both live and neutral wires. In this
case a line splitter is required, Klein Cat. No. 69409 is recommended.
AC/DC VOLTAGE (LESS THAN 600V DC OR 750V AC)
1. Insert RED test lead into VΩµA jack
5
, and BLACK test lead
into COM jack
4
, and rotate function selector switch
2
to the
V setting for AC or DC measurements. The meter defaults to
AC measurement. To measure DC, press the "SELECT" button
12
to toggle between AC and DC modes. The AC or DC icon on
the LCD indicates which mode is selected. Note "AC" or "DC" on
the display.
HOT WIRE
GROUND WIRE
LIVE
CABLE
NEUTRAL WIRE
11
OPERATING INSTRUCTIONS
Apply test leads to the circuit to be tested to measure voltage.
The meter will auto-range to display the measurement in the most
appropriate range.
NOTE: The Hazardous Voltage Indicator will appear on the display
when the voltage is >25V AC or >60V DC.
NOTE: If "" appears on the LCD, the test leads are being applied to
the circuit in reverse. Swap the position of the leads to correct this.
NOTE: To access mV range for V AC , the 'RANGE' button
7
must
be used.
NOTE: When in a voltage setting and the test leads are open,
readings of order mV may appear on the display. This is noise and
is normal. By touching the test leads together to close the circuit
the meter will measure zero volts.
INRUSH CURRENT
The Inrush feature captures starting current of a motor or transformer.
Starting current can assist in diagnosing a motor before it fails.
To measure inrush current:
1. Rotate the Function Selector switch
2
to the AC current A setting.
2. Place clamp
3
around wire. The current measurement will be
shown in the main display.
3. Press the "InRush" button
17
to enter the Inrush mode and manually
select 60A or 600A range
by pressing the "RANGE" button
7
.
Place the clamp around the compressor
start wire and turn motor on. The
starting current will hold on the main
display. Inrush mode takes a measurement every 20 milliseconds
and updates the display every 100 milliseconds. The secondary
display measures running current.
4. Press "InRush" button
17
to exit.
Manual Mode Sequence
First
Press Second
Press Third
Press Fourth
Press Fifth
Press
AC Range 0-750V 0-600.0V 0-60.00V 0-6.000V
0-600.0mV
DC Range 0-60.00V 0-6.000V
0-600.0mV
0-600.0V 0-60.00V
12
ENGLISH
CONTINUITY
1. Insert RED test lead into VΩµA jack
5
, and BLACK test lead
into COM jack
4
, and rotate function selector switch
2
to the
Continuity/Resistance/Capacitance/Diode-Test setting.
NOTE: The meter defaults to Continuity testing in this mode. Ensure
that the Continuity Testing icon is visible on the display. If not,
press the "SELECT" button
12
repeatedly until the icon is shown.
2. Remove power from circuit.
3. Test for continuity by connecting conductor or circuit with test
leads. If resistance is measured less than 10Ω, an audible signal
will sound and display will show a resistance value indicating
continuity. If circuit is open display will show "OL".
µA DC CURRENT (LESS THAN 600µA)
1. Insert RED test lead into VΩµA jack
5
, and BLACK test lead into
COM jack
4
, and rotate function selector switch
2
to the
µA setting.
2. Remove power from circuit and open circuit at measurement point.
3. Connect test leads in series with the circuit.
4. Apply power to the circuit to take the measurement.
DO NOT attempt to measure continuity on a live circuit.
OPERATING INSTRUCTIONS
DO NOT attempt to measure more than 600µA.
Red leadBlack lead
Red leadBlack lead
13
AC VOLTAGE + AC AMPERAGE FUNCTION
1. Insert RED test lead into VΩµA jack
5
, and BLACK test lead
into COM jack
4
, and rotate function selector switch
2
to the
V+A~ setting.
2. Press clamp trigger
10
to open clamp
3
and place around
current-carrying wire.
3. The main display will show AC Voltage and the secondary
display will show AC Amperage. Pressing the "SELECT" button
will reverse the displays; the main display will show AC
Amperage and the secondary display will show AC Voltage.
NOTE: The Hazardous Voltage Indicator will appear on the display
when the voltage is >25V AC or >60V DC.
OPERATING INSTRUCTIONS
RESISTANCE MEASUREMENTS
1. Insert RED test lead into VΩµA jack
5
, and BLACK test lead
into COM jack
4
, and rotate function selector switch
2
to the
Continuity/Resistance/Capacitance/Diode-Test setting.
NOTE: The meter defaults to Continuity testing in this mode. Press
the "SELECT" button
12
once to enter Resistance testing mode. The
Resistance icon will appear on the display.
2. Remove power from circuit.
3. Measure resistance by connecting test leads to circuit. The
meter will auto-range to display the measurement in the most
appropriate range.
NOTE: When in a Resistance setting and the test leads are open
(not connected across a resistor), or when a failed resistor is under
test, the display will indicate "OL". This is normal.
DO NOT attempt to measure resistance on a live circuit.
Red leadBlack lead
Red leadBlack lead
14
ENGLISH
CAPACITANCE
1. Insert RED test lead into VΩµA jack
5
, and BLACK test lead
into COM jack
4
, and rotate function selector switch
2
to the
Continuity/Resistance/Capacitance/Diode-Test setting.
NOTE: The meter defaults to Continuity testing in this mode. Press
the "SELECT" button
12
twice to enter Capacitance testing mode.
The capacitance unit F will appear on the display. The meter should
read 0 nF with test leads open.
2. Remove power from circuit.
3. Measure capacitance by connecting test leads across the
capacitor. The meter will auto-range to display the measurement
in the most appropriate range.
OPERATING INSTRUCTIONS
Red leadBlack lead
15
OPERATING INSTRUCTIONS
DIODE TEST
1. Insert RED test lead into VΩµA jack
5
, and BLACK test lead
into COM jack
4
, and rotate function selector switch
2
to the
Continuity/Resistance/Capacitance/Diode-Test setting.
NOTE: The meter defaults to Continuity testing in this mode. Press
the "SELECT" button
12
three times to enter Diode testing mode.
The Diode icon will appear on the display.
2. Touch test leads to diode. A reading of 200-800mV on display
indicates forward bias, "OL" indicates reverse bias. An open
device will show "OL" in both polarities. A shorted device will
show approximately 0mV.
FREQUENCY / DUTY-CYCLE
1. Insert RED test lead into VΩµA jack
5
and BLACK test lead
into COM jack
4
, and rotate function selector switch
2
to the
Frequency/Duty-Cycle setting.
2. Measure by connecting test leads across the circuit.
Red leadBlack lead
Red leadBlack lead
16
ENGLISH
OPERATING INSTRUCTIONS
TEMPERATURE
1. Remove leads from meter and slide the temperature probe input
switch
16
to close jacks and expose the K-Type thermocouple
ports.
2. Insert K-Type thermocouple into port
15
(observe polarity
markings on thermocouple and meter), and rotate function
selector switch
2
to the Temperature setting.
NOTE: The meter defaults to Fahrenheit scale in this mode. To
enter Celsius scale, press the
"SELECT"
button
12
. Ensure that the
appropriate icon (either
°F
or
°C
) appears on the display.
3. To measure temperature, make contact between the
thermocouple tip and the object being measured. When
thermocouple tip and object are in thermal equilibrium, the
measurement on the display will stabilize. The meter will auto-
range to display the measurement in the most appropriate range.
Remove thermocouple before switching meter to other
measurement functions.
T
he thermocouple included with the original purchase
is suitable for temperatures below 356°F / 180°C only.
To measure higher temperatures, a K-Type thermocouple
with the appropriate measurement range should be used.
K-Type Thermocouple
17
MAINTENANCE
BATTERY REPLACEMENT
When indicator is displayed on LCD, batteries must be replaced.
1. Loosen captive screw and remove battery cover.
2. Replace 3 × 1.5V AAA batteries (note proper polarity).
3. Replace battery cover and fasten screw securely.
T
o avoid risk of electric shock, disconnect leads from any
voltage source before removing battery door.
To avoid risk of electric shock, do not operate meter while
battery door is removed.
18
ENGLISH
CLEANING
Be sure meter is turned off and wipe with a clean, dry lint-free
cloth.
Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when meter is not in use for a prolonged
period of time. Do not expose to high temperatures or
humidity. After a period of storage in extreme conditions
exceeding the limits mentioned in the General Specifications
section, allow the meter to return to normal operating
conditions before using.
FCC & IC COMPLIANCE
See this product’s page at www.kleintools.com
for FCC compliance information.
Canada ICES-003 (B) / NMB-003 (B)
WARRANTY
www.kleintools.com/warranty
DISPOSAL / RECYCLE
Do not place equipment and its accessories in the trash.
Items must be properly disposed of in accordance with local
regulations. Please see www.epa.gov/recycle for additional
information.
CUSTOMER SERVICE
KLEINTOOLS, INC.
450Bond Street
Lincolnshire, IL60069
1-800-553-4676
www.kleintools.com
ESPAÑOL
MANUAL DE INSTRUCCIONES
Multímetro de gancho para HVAC
TRMS
Tecnología
de medición
MICROAMPERIOS CD
CORRIENTE
DEINSERCIÓN
PRUEBA DE VOLTAJE
SIN CONTACTO
RANGO AUTOMÁTICO
TEMPERATURA
INDICADOR DE
CONTINUIDAD AUDIBLE
5001748
750 V
600 V
600 A
60 M
Ω
2m
-148°F –
1832°F
-100°C –
1000°C
CL445
CAT IV
600 V
Multímetro de gancho para HVAC
MICROAMPERIOS CD
PRUEBA DE VOLTAJE
RANGO AUTOMÁTICO
CONTINUIDAD AUDIBLE
Multímetro de gancho para HVAC
CONTINUIDAD AUDIBLE
20
ESPAÑOL
ESPECIFICACIONES GENERALES
El CL445 de Klein Tools es un multímetro digital de gancho de rango
automático con media cuadrática real (TRMS) que mide corriente CA y
corriente de inserción con la pinza, así como el voltaje CA/CD, microamperios
CD, resistencia, continuidad, frecuencia y capacitancia, prueba diodos con
cables de prueba y mide temperatura con una sonda de termopar.
Entorno: interiores. NO lo exponga a la humedad, lluvia o nieve.
Altitud de funcionamiento: 6562' (2000m)
Humedad relativa: <95%, sin condensación
Temperatura de funcionamiento: 32 a 122°F (0 a 50°C)
Temperatura de almacenamiento: 14 a 122°F (-10 a 50°C)
Precisión: valores establecidos a una temperatura de 65 a 83°F (18 a 28°C)
Coe ciente de temperatura: 0,1 × (precisión indicada) por cada °C por
encima de los 28°C o por debajo de los 18°C; es necesario realizar
correcciones si la temperatura de trabajo se encuentra fuera del rango de
la temperatura de precisión
Dimensiones: 9,24"×3,77"×1,59"(235×96×40mm)
Peso: 12,58oz (356,5g) incluidas las baterías
Calibración: precisa durante un año
Función de apagado automático (APO): después deaproximadamente
10minutos de inactividad
Normas: IEC/BS/EN 61010-1, 61010-2-032,
IEC/BS/EN 61326-1, 61326-2-2.
Cumple con las normas UL STD.61010-1, 61010-2-032;
Certificado según las normas CSA STD.C22.2 n.º 61010-1,
61010-2-032.
Grado de contaminación: 2
Precisión: ± (% de lectura + cantidad de dígitos menos significativos)
Clasi cación de seguridad: CATIV 600V
Clase2, doble aislamiento
Protección ante caídas: 6,6' (2m)
CATIII: la categoríaIII de medición es aplicable a los circuitos de
medición y prueba conectados a la distribución de la instalación de redes
eléctricas de bajo voltaje de un edificio.
CATIV: la categoríaIV de medición es aplicable a los circuitos de
medición y prueba conectados a la fuente de la instalación deredes
eléctricas de bajo voltaje de un edificio.
Entorno electromagnético: IEC EN 61326-1. Este equipo cumple con los
requisitos para su uso en entornos electromagnéticos básicos y controlados,
como propiedades residenciales, establecimientos comerciales e instalaciones
de industria ligera.
Especificaciones sujetas a cambios.
5001748
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56

Klein Tools CL445 Manuel utilisateur

Catégorie
Mesure, test
Taper
Manuel utilisateur

dans d''autres langues