FCC Statements:
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment o and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit dierent from that to
which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
To satisfy FCC/ISED RF exposure requirements a separation distance of
20 cm or more must be maintained between the antenna of this device
and persons during operation. Operation at closer than 20 cm is not
permitted.
CAN ICES-5 (B)/NMB-3(B)
This device complies with Industry Canada license-exempt RSS standards.
Operation is subject to the following two conditions:
This device may not cause harmful interference, and
This device must accept any interference received, including interference
that may cause undesired operation.
Cet appareil est conforme aux normes RSS exemptees de licence de
Industrie Canada. Son fonctionnement est soumis aux deux conditions
suivantes:
Cet appareil ne doit pas provoquer d’interférences et
Cet appareil doit accepter toute interférence, y compris celles pouvant
causer un mauvais fonctionnement de l’appareil.
Pour être conforme aux limites d’exposition aux ondes RF des normes
FCC/ISED, une distance de séparation d’au moins 20 cm doit être
maintenue entre l’antenne de cet appareil et toute personne pendant
son opération. Mettre en opération cet appareil a une distance plus
rapprochée que 20 cm n’est pas permis.
WARNING
RISK OF ELECTRIC SHOCK
Disconnect power before servicing or installing product.
RISK OF INJURY OR DAMAGE
Unit will fall if not installed properly. Follow installation
instructions. Install in accordance with National Electric Code
and local codes.
CAUTION
RISK OF INJURY
Wear safety glasses and gloves during installation and servicing.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
2
Installation Guide
LightGrid Node 2.x Series
Before Installation
How to Install the LightGrid 2.x Controller
(The GESEM65-3 module is pictured below, however the instructions are applicable across the entire Select TXTM Gen3
family of modules.)
Carefully unpack unit. Inspect for defects before installing.
Check electrical parameters. Ensure that the xture operating wattage is below 1000W, and the voltage at the
pole is within the allowed range of the Controller (range is listed on the sticker on the bottom of the controller).
Using controller outside these parameters will void its warranty.
Verify that power to the luminaire is ON 24/7 constant power. The LightGrid mesh will not operate properly
when operating on switched power from a master timer or photocell.
Conrm that the controller is the correct network ID for the system it is intended to join. This will be on the
sticker on the bottom of the node, labeled as Net A, Net B, Net C … this must match the other controllers in the
area or the node will not join the network.
Install the gateways rst. The startup and formation of the network is faster and smoother process when the
Gateways are installed before starting to install Controllers.
Plan an installation route. Generally it is best to install controllers nearest to the gateways rst, and then proceed
outwards.
Check nearby poles. At the pole to be installed, conrm there is either a Gateway or another active LightGrid
Controller within 1000Ft. This is important, to make sure the node has a connection path for communications
and is within its RF range limits.
Ensure Cellular Service is Accessible: Prior to installing cellular nodes verify with LightGrid support team that
cellular service is available at the location, providing latitude and longitude coordinates.
Plug in the node: Orient controller so large blade aligns with large slot in receptacle. Plug in, then twist
clockwise until it is fully locked in place (Figure A).
Conrm the xture dims during the rst 60 seconds. When the controller is rst plugged in, it will turn the
luminaire ON and will then dim the luminaire. Before leaving the pole, you must visually conrm that you see
the brightness of the luminaire drop, in order to conrm that dimming is working properly. Note: applies only to
dimmable xtures with an ANSI 5 Pin or 7 Pin socket. Fixtures with a standard 3 Pin socket will not be dimmable.
Orient the Controller towards North: Lift up on the controller, which will also lift the receptacle with it. While
lifting, rotate the controller and socket until the word North on the top of the controller is directed toward true
North. Then lower the assembly back into place (Figure B).
Make sure red and yellow indicator LEDs are blinking. This conrms the controller is looking for a network to join.
1
3
2
4
5
6
Figure A Figure B
North
www.gecurrent.com
© 2021 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the
General Electric Company and are used under license. Information provided is subject to change without
notice. All values are design or typical values when measured under laboratory conditions.
CTRL044 (Rev 05/18/21)
Installation Guide
LightGrid Node 2.x Series
Questions
Leave a Voicemail: 1-877-843-5590
Troubleshooting
Symptom Solution
The luminaire is not
turning ON.
Check that the pole has power. The relay inside the Controller is Normally Closed, so the
luminaire will always turn ON when the controller is rst plugged in.
I did not see the
dimming sequence in the
rst 60 seconds.
Unplug the controller, and try plugging it in again. If you still do not see the sequence, check
that the dimming wires of the xture (Grey & Violet) are properly connected to the dimming
wires of the ANSI socket. If you conrm the wiring is connected and the controller still does
not dim the luminaire, try another new controller.