Lithionics Battery GTX12V630A-E2112-CS200 Guide d'installation

Taper
Guide d'installation
NeverDie® Compact Series 200 Internal BMS
MiniBMS
GTX12V630A-E2112-CS200 Installation Manual
RevB
®
TECHNOLOGY
®
LITHIONICS BATTERY, 1770 CALUMET ST, CLEARWATER, FL 33765 USA
PH: 727.726.4204 | FAX: 727.797.8046 | WEB: LITHIONICSBATTERY.COM
Page 2 of 15
Important Safety Guidelines
This guide contains important safety instructions for the GTX12V630A-E2112-CS200 Battery System that must be
followed during installation procedures. Completely read this manual and become familiar with all system components
before attempting installation. Save this installation manual for future reference.
The following symbols and messages are used to identify potential hazards or to clarify the procedure.
The CAUTION symbol indicates a hazardous situation which, if not avoided, could result in moderate or minor injury.
The DANGER symbol indicates a hazardous situation which, if not avoided, will result in death or serious injury.
Safety Information
1. Before using the Battery System, read all instructions and cautionary markings on the unit, the BMS, and all
appropriate sections of this manual.
2. The information in this manual is intended for qualified personnel. Qualified personnel have training,
knowledge, and experience in:
Selecting and using Personal Protective Equipment (PPE).
Installing electrical equipment.
Applying all applicable local and national installation codes.
Analyzing and reducing the hazards involved in performing electrical work.
3. Use of accessories not recommended or sold by the manufacturer may result in a risk of fire, electric shock, or
injury to persons.
4. To avoid a risk of fire and electric shock, make sure that existing wiring is in good condition and that wire is not
undersized. Do not operate the battery system with damaged or substandard wiring.
5. Do not operate the battery system if it has been damaged in any way.
6. This unit does not have any user-serviceable parts. Do not disassemble the battery system except where noted
for connecting wiring and cabling. Attempting to service the unit yourself may result in a risk of electrical shock
or fire. Internal cells remain charged after all power is disconnected.
7. To reduce the chance of short-circuits, always use insulated tools when installing or working with this
equipment.
8. Remove personal metal items such as rings, bracelets, necklaces, and watches when working with electrical
equipment.
LITHIONICS BATTERY, 1770 CALUMET ST, CLEARWATER, FL 33765 USA
PH: 727.726.4204 | FAX: 727.797.8046 | WEB: LITHIONICSBATTERY.COM
Page 3 of 15
If the system is operated outside of its limits and/or used in combination with non-original components without
authorization, the warranty is void.
Do not expose this unit to direct sunlight, external heat sources or submersion in any liquid. This product is
designed for closed compartment use only. Damage to any part of the battery system caused from direct sunlight,
external heat sources or submersion in any liquid will not be covered by the product warranty.
The Battery is tested to comply with UN DOT 38.3, the testing requirement for Lithium Batteries per Part III; of the
UN Recommendations on the TRANSPORT OF DANGEROUS GOODS (Manual of Tests and Criteria, Fifth revised
edition); [ST/SG/AC.10/11/Rev.5].
This Battery contains no mercury and is RoHS Compliant. Please consult your local municipal authority for proper disposal.
HAZARD OF ELECTROLYTE VAPOR
The battery may emit a non-toxic pressurized electrolyte vapor if punctured.
Electrolyte vapor may cause temporary minor breathing congestion.
Electrolyte vapor can decrease visibility in closed compartments.
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
Apply appropriate personal protective equipment (PPE) and follow safe electrical work
practices.
Always turn OFF all equipment connected to the system in addition to turning OFF the
power switch provided on the system to isolate the batteries from other electrical
circuits, before performing any repairs or maintenance on the system.
Do not operate the system if it has received a sharp blow, been dropped, has cracks or
openings in the enclosure.
Do not disassemble any part of the system. Internal cells remain charged after all power
is disconnected.
Do not operate the system with damaged or substandard wiring.
Always use proper wire sizes to connect the system to inverters, chargers or other
equipment.
Voltage is present at the connector and output terminals. Always ensure that the BMS
output terminals have the insulated protective boots in place.
Always use crimped connections to connect to the output terminals.
Always use a properly rated voltage sensing device to confirm all circuits are de-
energized.
HAZARD OF HEAVY EQUIPMENT
Use two people to lift and mount the battery.
Always use proper lifting techniques during installation to prevent injury.
Do not lift the battery by its power or signal wires as they will become damaged.
LITHIONICS BATTERY, 1770 CALUMET ST, CLEARWATER, FL 33765 USA
PH: 727.726.4204 | FAX: 727.797.8046 | WEB: LITHIONICSBATTERY.COM
Page 4 of 15
Consignes de Sécurité Importantes
Ce guide contient des instructions de sécurité importantes pour le système de batterie GTX12V630A-E2112-CS200 qui
doivent être suivies pendant les procédures d'installation. Lisez entièrement ce manuel et familiarisez-vous avec tous les
composants du système avant de tenter l'installation. Conservez ce manuel d'installation pour référence future.
Les symboles et messages suivants sont utilis pour identifier les dangers potentiels ou pour clarifier la
procédure.
Le mot ATTENTION indique une situation potentiellement dangereuse, laquelle, si elle n'est pas évitée, pourrait entraîner
des blessures mineures ou modérées.
Le mot DANGER indique une situation dangereuse imminente, laquelle, si elle n'est pas évitée, entraînera de graves
blessures, voire la mort.
Information sur la Sécurité
1. Avant d'utiliser le système de batterie, lisez toutes les instructions et les avertissements sur l'unité, le BMS et
toutes les sections appropriées de ce manuel.
2. Les informations contenues dans ce manuel sont destinées au personnel qualifié. Le personnel qualifié possède
une formation, des connaissances et une expérience en:
Sélection et utilisation des équipements de protection individuelle (EPI).
Installation d’équipements électriques.
Appliquer tous les codes d'installation locaux et nationaux applicables.
Analyser et réduire les risques liés à l'exécution des travaux électriques.
3. L'utilisation d'accessoires non recommandés ou vendus par le fabricant peut entraîner un risque d'incendie, de
choc électrique ou de blessures corporelles..
4. Pour éviter tout risque d'incendie et d'électrocution, assurez-vous que le câblage existant est en bon état et
que le fil n'est pas sous-dimensionné. Ne pas faire fonctionner le système de batterie avec un câblage
endommagé ou de qualité inférieure.
5. N'utilisez pas le système de batterie s'il a été endommagé de quelque manière que ce soit.
6. Cet appareil ne contient aucune pièce réparable par l'utilisateur. Ne démontez pas le système de batterie, sauf
indication contraire pour le câblage et le câblage. Tenter de réparer l'appareil vous-même peut entraîner un
risque d'électrocution ou d'incendie. Les cellules internes restent chargées une fois que toute l'alimentation est
coupée.
7. Pour réduire les risques de courts-circuits, utilisez toujours des outils isolés lors de l'installation ou de
l'utilisation de cet équipement.
8. Retirez les objets métalliques personnels tels que bagues, bracelets, colliers et montres lorsque vous travaillez
avec des équipements électriques.
LITHIONICS BATTERY, 1770 CALUMET ST, CLEARWATER, FL 33765 USA
PH: 727.726.4204 | FAX: 727.797.8046 | WEB: LITHIONICSBATTERY.COM
Page 5 of 15
Si le système est utilisé en dehors de ses limites et / ou utilisé en combinaison avec des composants non originaux sans
autorisation, la garantie est nulle.
N'exposez pas cet appareil à la lumière directe du soleil, à des sources de chaleur externes ou à une immersion dans un
liquide. Ce produit est conçu pour une utilisation à compartiment fermé uniquement. Les dommages à toute partie du
système de batterie causés par la lumière directe du soleil, des sources de chaleur externes ou une submersion dans un
liquide ne seront pas couverts par la garantie du produit.
Le batterie et le BMS sont testés pour se conformer à UN DOT 38.3, l'exigence de test pour les batteries au lithium selon la
partie III; des Recommandations des Nations Unies sur le TRANSPORT DES MARCHANDISES DANGEREUSES (Manuel
d'épreuves et de critères, cinquième édition révisée); [ST/SG/AC.10/11/Rev.5].
Ce batterie ne contient pas de mercure et est conforme RoHS. Veuillez consulter les autorités municipales locales pour une
élimination appropriée.
RISQUE DE VAPEUR D'ÉLECTROLYTE
Le batterie peut émettre une vapeur d'électrolyte sous pression non toxique s'il est perforé.
Les vapeurs d'électrolyte peuvent causer une congestion respiratoire mineure temporaire.
La vapeur d'électrolyte peut diminuer la visibilité dans les compartiments fermés.
RISQUE DE CHOC ÉLECTRIQUE, D'EXPLOSION OU D'ARC ÉLECTRIQUE
Appliquer un équipement de protection individuelle (EPI) approprié et suivre des pratiques de
travail électrique sûres.
Éteignez toujours tous les équipements connectés au système en plus de désactiver
l'interrupteur d'alimentation fourni sur le système pour isoler les batteries des autres circuits
électriques, avant d'effectuer toute réparation ou maintenance sur le système.
N'utilisez pas le système s'il a reçu un coup violent, s'il est tombé, s'il présente des fissures ou
des ouvertures dans le boîtier.
Ne démontez aucune pièce du système. Les cellules internes restent chargées une fois que
toute l'alimentation est déconnectée.
N'utilisez pas le système avec un câblage endommagé ou de qualité inférieure.
Utilisez toujours des câbles de taille appropriée pour connecter le système aux onduleurs,
chargeurs ou autres équipements.
Une tension est présente au niveau du connecteur et des bornes de sortie. Assurez-vous
toujours que les bornes de sortie BMS ont les bottes de protection isolées en place.
Utilisez toujours des connexions serties pour vous connecter aux bornes de sortie.
Utilisez toujours un dispositif de détection de tension correctement évalué pour confirmer
que tous les circuits sont hors tension.
RISQUE D'ÉQUIPEMENT LOURD
Utilisez deux personnes pour soulever et monter le batterie.
Utilisez toujours des techniques de levage appropriées lors de l'installation pour éviter les
blessures.
Ne soulevez pas le batterie par ses fils d'alimentation ou de signal car ils seront endommagés.
LITHIONICS BATTERY, 1770 CALUMET ST, CLEARWATER, FL 33765 USA
PH: 727.726.4204 | FAX: 727.797.8046 | WEB: LITHIONICSBATTERY.COM
Page 6 of 15
Notice of Copyright
GTX12V630A-E2112-CS200 Installation Manual Copyright © 2021 all rights reserved. No part of this document may be
reproduced in any form without the express consent of Lithionics Battery®, Clearwater, FL 33765 USA. Lithionics Battery®
reserves the right to revise this document and make periodic changes to the contents without notice.
Index
Index................................................................................................................................................................................ 6
Safety .............................................................................................................................................................................. 6
Overview ......................................................................................................................................................................... 6
1. System Components ................................................................................................................................................... 7
2. System Specifications ................................................................................................................................................. 9
3. System Installation ................................................................................................................................................... 11
4. System Operation ..................................................................................................................................................... 11
Contact Information ..................................................................................................................................................... 15
Safety
All electrical work shall be performed in accordance with local and national electrical codes.
Assume that voltage is present at the battery terminals, use insulated tools and gloves while working on the system.
Always turn OFF equipment connected to the battery in addition to turning OFF the Power button on the battery to
isolate it from other electrical circuits before performing any repairs, maintenance, or diagnosis on the system.
Always use proper wire sizes to connect the system to inverters, chargers, or other equipment.
Always use crimped connections to connect to the battery terminals.
Read and follow the inverter, charger, or other equipment manufacturers safety precautions prior to connecting the
battery to that equipment.
Always use charging equipment compatible with Lithium Iron Phosphate battery chemistry. See battery charging
section below.
Overview
This Guide is intended to be used by qualified individuals in the installation of the GTX12V630A-E2112-CS200 battery
system.
LITHIONICS BATTERY, 1770 CALUMET ST, CLEARWATER, FL 33765 USA
PH: 727.726.4204 | FAX: 727.797.8046 | WEB: LITHIONICSBATTERY.COM
Page 7 of 15
1. System Components
1.1 Components
GTX12V630A-E2112-CS200 Battery
Accessory Harness (#75-H1FBR-CS2)*
Protective DC Terminal Covers (Red & Black, not shown)
Two Sets of M8x12x1.25mm Bolts and Lock Washers for the Terminals
Wiring and bus bars are not included.
NOTE - It is recommended to keep the battery box and packaging material in case you need to return for service.
Reference
Feature
Description
A
OptoLoop®+ Connector
RV-C CANBus Data, Remote Display Unit
B
Accessory Connector
FCC, Remote Power Button
C
Positive Terminal
Brass, Nickel Plated, M8-1.25 Thread, Torque to 108-132in-lbs (12.2 14.9N-m)
D
Vent
Pressure Balancing Vent
E
Power Button
Power Button with Status Light
F
Negative Terminal
Brass, Nickel Plated, M8-1.25 Thread, Torque to 108-132in-lbs (12.2 14.9N-m)
G*
Accessory Harness
Enables Integration of FCC and Remote Power Button
*Accessory Harness is an optional part.
Accessory Harness
GTX12V630A-E2112-CS200 Battery
Battery
G
LITHIONICS BATTERY, 1770 CALUMET ST, CLEARWATER, FL 33765 USA
PH: 727.726.4204 | FAX: 727.797.8046 | WEB: LITHIONICSBATTERY.COM
Page 8 of 15
1.2 Accessory Harness
The Accessory Harness connects to the battery and is used to access the BMS’s ported features. This allows
implementation of the features shown below.
75-H1FBR-CS2 Accessory Harness
LITHIONICS BATTERY, 1770 CALUMET ST, CLEARWATER, FL 33765 USA
PH: 727.726.4204 | FAX: 727.797.8046 | WEB: LITHIONICSBATTERY.COM
Page 9 of 15
2. System Specifications
2.1 Operating Specifications
Table 1
System Model: GTX12V630A-E2112-CS200
Capacity 630Ah
Nominal Voltage 12.8V
Recommended Charging
Voltage
14.4V
Maximum Charging
Voltage
14.8V @ 200A
Over-discharge Voltage
Protection
10.0V @ 230A
Standard Charging
Current
150A
Maximum Charging
Current
200A
Charge Termination
Current
10A
Standard Discharging
Current/Load
150A
Maximum Discharge
Current/Load
230A
System Impedance at
Terminals
2.20m
Ibf Bolted Fault Current
at Nominal Voltage (N2)
5818A
Maximum Charging
Temperature Range (N1)
32 to 131°F (0 to 55°C)
Maximum Discharging
Temperature Range (N1)
-4 to 131°F (-20 to 55°C)
Battery Dimensions 20.3" x 12.3" x 10.6" (516 x 312 x 269mm)
Battery Weight 128lb (58.0kg)
Notes for Table 1:
(N1) Maximum charging and discharging rates apply depending upon the ambient temperature and duty cycle of the system. UL1973 tests of maximum
charge and discharge current were performed at 25°C/77°F.
(N2) "Bolted Fault Current" per NFPA-70E. See section 1.2 for details.
2.2 Arc Flash Energy Specifications
An arc flash is the light and heat produced from an electric arc supplied with sufficient electrical energy to cause
substantial damage, harm, fire, or injury.
o An example of an arc flash event could be a direct short circuit caused by a metallic object such as a tool bridging
between the positive and negative of an energized circuit.
o Table 3 below quantifies the hazard level of arc flash energy that each battery system is capable of producing.
Per NFPA 70E D.5.1 "Maximum Power Method"
Iarc = 0.5 x Ibf
IEm = 0.01*Vsys* Iarc*Tarc/D2 (Arc Flash Energy)
Table 3
GTX12V630A-E2112-CS200 12.8 2.20 5818 2909 0.360 1.079 9 0
Tarc= 80mS
circuit breaker
clearing time
Hazard
level
Distance where
IEm=1.2 (Arc
Boundary), inches.
3x IEm
cal/cm^
2
IEm cal/cm^2
Iarc
Ibf, calc.
Impedance
Vsys
Configuration
Hazard/risk classification as per NFPA 70E-2000
LITHIONICS BATTERY, 1770 CALUMET ST, CLEARWATER, FL 33765 USA
PH: 727.726.4204 | FAX: 727.797.8046 | WEB: LITHIONICSBATTERY.COM
Page 10 of 15
2.3 Manufacturing Date Code Format
MMDDYYYY001
o MM: Month of Manufacture
o DD: Day of that Month
o YYYY: Year of Manufacture
o 001: Sequence of Battery Produced on That Day
Example: 01012020001 = manufactured on January 1, 2020 and it was the first battery produced on that day.
LITHIONICS BATTERY, 1770 CALUMET ST, CLEARWATER, FL 33765 USA
PH: 727.726.4204 | FAX: 727.797.8046 | WEB: LITHIONICSBATTERY.COM
Page 11 of 15
3. System Installation
3.1 Battery Environment and Mounting orientation
The Battery needs to be mounted in an environment that does not receive direct sunlight, pressurized water, or road
debris.
To avoid power interruption, your installation may need to consider controlling the ambient operating temperature.
Mount the Battery in an upright position, i.e. black lid faces up.
o Other orientations are NOT permitted and will void the warranty.
3.2 Battery Power Terminals (see Figure 3 for diagram)
Connect the Battery Negative Terminal to your DC negative bus.
o Use 2/0 wire and 2/0 3/8” stud ring terminals.
o The battery negative wire is recommended to be 3ft or less.
o Torque the battery negative power terminal to 108 - 132in-lbs (12.2 - 14.9N-m).
Connect the Battery Positive Terminal to your DC positive bus. (Figure 3).
o Use 2/0 wire and 2/0 3/8” stud ring terminals.
o The battery positive wire is recommended to be 3ft or less.
o Torque the battery positive power terminal to 108 - 132in-lbs (12.2 - 14.9N-m).
o Never stack ring terminals.
o Never place the stainless-steel washer or lock-washer between the conductive power terminal and ring terminal
lug (see Figure 2 on Page 13).
3.3 Accessory Harness
If applicable, connect the FCC circuit and Remote Power Button to your accessory harness.
Connect the Accessory Harness to the Accessory Connector on the Battery (Figure 1, B).
3.4 Initial Charge Cycle
Initially the system must be FULLY charged once to calibrate the Battery. Please read and follow the next section to
perform this.
4. System Operation
4.1 Powering the System On
Short-press the Power switch for 1 second.
o The switch will illuminate once power is enabled.
o Check that there is voltage at the Power Terminals with a voltmeter.
4.2 Powering the System Off
Long-press the Power switch for 3 seconds.
o The switch will cease to illuminate once power is disabled.
o Check that there is 0V at the output terminals with a voltmeter.
4.3 Charging
The charging device(s) connected to the Lithium Battery System must be programmed as per Table 1.
Charging may be performed at any time the system is powered On.
o NOTE The Battery will disconnect power if the voltage, amperage, or temperature limits are exceeded during
charging.
o Only use a Lithionics Battery approved charging source. Please contact Lithionics Battery for charger approval.
4.4 Initial Charging Cycle
LITHIONICS BATTERY, 1770 CALUMET ST, CLEARWATER, FL 33765 USA
PH: 727.726.4204 | FAX: 727.797.8046 | WEB: LITHIONICSBATTERY.COM
Page 12 of 15
The initial charging cycle is required as it calibrates the Battery for accurate State of Charge percentage (SoC)
monitoring.
During the initial charging cycle, the system must reach a voltage level that is equal to the Standard Full Charging
Voltage indicated in Table 1.
Enable the charging device(s) so that they may complete a charge cycle. It is recommended to not have any discharge
loads active during the initial charging cycle, especially towards the end of charging.
4.5 Discharging
Discharging may be performed at any time the system is powered On.
o NOTE - The Battery will disconnect power if the voltage, amperage, or temperature limits are exceeded during
discharging.
The NeverDie feature allows the system to have a “reserve” amount of energy left in the battery. Once the system is
discharged to 12.0V or 10% State of Charge (SoC), whichever comes first, power will be disabled to leave a “reserve”
amount of energy still left in the battery.
To enable the remaining reserve energy of the system, short-press the Power switch for 1 second.
o NOTE - Once the reserve range is enabled the battery should be charged as soon as possible.
o WARNING - If the reserve energy is used and the battery is left in a deeply discharged state without immediate
charging, the battery will become permanently damaged.
4.6 System Storage Procedure
Storing your battery at the correct specifications is important as it keeps the battery in the healthiest state possible
for the fastest deployment when needed.
If the Lithium Battery System will not be in use for greater than 2 weeks, it is recommended to enable system storage.
Storage mode is simply a fully charged system in the Powered Off state.
To enable System Storage:
o Perform a full charge cycle, ensure that the System voltage reaches the Standard Full Charging Voltage indicated in
Table 1.
o Power off the System, long-press the Power switch for 3 seconds. Check that the switch is no longer illuminated.
Check that there is 0V at the Power Terminals with a voltmeter.
Table 3
Storage Temperature
& Humidity Range
< 1 Month
-4~95°F (-20~35°C), 45~75%RH
< 3 Months
14~86°F (-10~30°C), 45~75%RH
Long Term Storage
If the battery needs to be stored for > 3 months, the voltage should be 13.2V (50%SOC) and
stored at the recommended storage specifications shown above. Additionally, the battery
needs at least one charge & discharge cycle every six months.
Self-discharge rate
≤3% per month
Storage conditions < 3 months:
1. Fully charge the battery.
2. Turn the battery OFF by the Power/Reset switch.
3. Store the battery in an environment according to the specifications shown above.
Storage conditions > 3 months:
1. Reduce the battery SOC to 13.2V which is 50% ±10% SOC.
2. Turn the battery OFF via the Power/Reset switch.
3. Store the battery in an environment according to the specifications shown in table 3 above.
4. Every 6 months charge the battery to 100% SOC, then discharge the battery to LVC, then charge it to 50% ±10%
SOC.
LITHIONICS BATTERY, 1770 CALUMET ST, CLEARWATER, FL 33765 USA
PH: 727.726.4204 | FAX: 727.797.8046 | WEB: LITHIONICSBATTERY.COM
Page 13 of 15
NOTE For further system installation and operation please refer to the Advanced Series User Guide available at:
http://www.lithionicsbattery.com/user-guides/
Figure 2
LITHIONICS BATTERY, 1770 CALUMET ST, CLEARWATER, FL 33765 USA
PH: 727.726.4204 | FAX: 727.797.8046 | WEB: LITHIONICSBATTERY.COM
Page 14 of 15
Figure 3
LITHIONICS BATTERY, 1770 CALUMET ST, CLEARWATER, FL 33765 USA
PH: 727.726.4204 | FAX: 727.797.8046 | WEB: LITHIONICSBATTERY.COM
Page 15 of 15
Contact Information
For technical or warranty support please first contact the dealer where the system was purchased.
Additionally, for factory support please send an email with your battery’s serial number to Support@LithionicsBattery.com.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15

Lithionics Battery GTX12V630A-E2112-CS200 Guide d'installation

Taper
Guide d'installation