MrSteam AromaFlo System Installation & Operation Manual

Taper
Installation & Operation Manual
mr
.steam® l Feel Good Inc.
®
AromaFlo
Installation, Operation & Maintenance Manual
Fragrance Metering Pump System for
Commercial Steam Rooms
Part Number CU-AROMAFLOA
__________________________________
IMPORTANT: Leave this material with the operator.
__________________________________
This installation, operation and maintenance manual is for general reference.
The installation, operation and maintenance manual supplied with the product must be used for
installation, operation and maintenance purposes. Failure to use the installation, operation and
maintenance manual supplied may result in a property damage or personal injury.
WARNING
!
TABLE OF CONTENTS
Installer’s Section:
Box Contents ........................................3
Important Safety Information ...............4
System Overview ..................................5
General System Dimensions ................6
General Installation .........................7-11
Operation ...........................................12
Troubleshooting ................................. 13
Replacement Parts .............................14
Installing the Caddy ......................15-16
Operator’s Section
Fragrances .........................................17
Important Safety Information .............18
Locating the Caddy ............................19
Pump Operation............................19-20
Warranty .............................................20
BEFORE INSTALLING
Carefully inspect the AromaFlo pump and packaging for ship-
ping damage. In the event of shipping damage, please contact
the carrier for claim information. Our customer service depart-
ment can assist you with product replacement.
Read these instructions before installation or service. Although
the AromaFlo pump has been fully qualified for shipment by
MrSteam, the following must be reviewed for proper, safe and
enjoyable steam bathing:
1. Verify that the model and accessories specifications are cor-
rect for the application.
2. The physical size of the unit, clearance for plumbing servic-
ing, its distance from the steam room and fragrance location
must all be considered before final installation.
3. Consider any controls and accessories before initiating
installation. Read the Installation and Operation Manual of
all controls and accessories available at www.mrsteam.com
technical downloads.
IMPORTANT NOTES:
This document contains important safety, operation and main-
tenance information. After installation leave this document
with the operator. Do not discard this document.
The following general information should be used in conjunc-
tion with consultations with an architect, designer and contrac-
tor in determining factors necessary in providing a suitable and
safe steam room. MrSteam AromaFlo pumps are intended to
be operated with MrSteam CU commercial steam bath gen-
erators and are to be installed strictly in accordance with the
specific instructions contained in this manual and as supplied
in the manuals provided with the controls or accessories.
1
INSTALLER SECTION
AromaFlo Operation and Installation Instructions
®
IMPORTANT NOTE:
This “peel and stick” warning
label shall be posted in a
conspicuous location next to
the steam room door.
PUR100193 Rev 5.22
This room is equipped with an automatic
aromatic dispensing system. Leave Room
immediately if you have any adverse or
allergic reaction, including difficulty
breathing, or eye, nasal or throat irritation.
Mr. Steam
43-20 34th Street, Long Island City, New York 11101
800 767 8326
PN PUR100381 8/22
IMPORTANT NOTE:
As you follow these instructions, you will notice warning and caution
symbols. This blocked information is important for the safe and efficient installation and use of
the pump, fragrance and caddy. These are types of potential hazards that may occur during
installation and operation:
states a hazard may cause serious injury or death if precautions are not followed.
signals a situation where minor injury or product damage may occur if you do not
follow instructions.
IMPORTANT NOTE: This highlights information that is especially relevant to a problem-free
installation.
All information in these instructions is based on the latest product information available at the
time of publication.
MrSteam reserves the right to make changes at any time without notice.
WARNING
!
CAUTION
!
Pump Caddy
Additional Items included but not shown:
U ÓÝÊÕÌ}Ê-VÀiÜÃÊ>`ÊVÀÃÊvÀÊ>``ÞÊ>`Ê*Õ«
U ÕÃi
Box Contents
Check Valve Injector with
Injector Tubing
Installation &
Operation Manual
All Drawings for Illustrative Purposes Only
Pressure Tube
Assembly Suction Tube
Assembly
2
INSTALLER SECTION
AromaFlo Operation and Installation Instructions
®
All Drawings for Illustrative Purposes Only
This room is equipped with an automatic
aromatic dispensing system. Leave Room
immediately if you have any adverse or
allergic reaction, including difficulty
breathing, or eye, nasal or throat irritation.
Mr. Steam
43-20 34th Street, Long Island City, New York 11101
800 767 8326
PN PUR100381 8/22
Warning Sign
(Includes mounting hardware)
Û`ÊVÌ>VÌÊÜÌÊiÞiðÊ>ÞÊV>ÕÃiÊ`ÊiÞiÊÀÀÌ>Ì°Ê
Ingestion may cause irritation, nausea, vomiting.
6>«ÀÃÊ>ÞÊV>ÕÃiÊ`ÀÜÃiÃÃ]Ê>iÀ}VÊÀi>VÌÃ]Ê
difficulty breathing or skin irritation. If condition
persists get medical attention.
À-Ìi>ÊvÀ>}À>ViÃÊCU-EUCALYPTUS, CU-LAVENDER)
are only for use with the MrSteam AromaFlo
dispensing pump (part number CU-AROMAFLO).
Never use MrSteam fragrances in any other pump,
spray or dispensing device. The use of MrSteam fra-
grances in any other device may introduce excessive
concentration of fragrances into the steam room and
may cause personal injury.
/iÊÕÃiÊvÊ>ÞÊvÀ>}À>ViÃÊÌiÀÊÌ>ÊÀ-Ìi>ÊvÀ>-
grances with a MrSteam AromaFlo dispensing pump
may introduce excessive concentration of fragrances
into the steam room, resulting in personal injury.
WARNING
!
WARNING
!
FIRST AID
IMPORTANT NOTES:
/iÊ->viÌÞÊ>Ì>Ê-iiÌÊ«ÀÛ`iÃÊV«ÀiiÃÛiÊ
information about MrSteam fragrances. Contact
1-800-767-8326 or go online at www.mrsteam.com
for a copy of the Safety Data Sheet.
-Ìi>ÊÀ>ÊvÀ>}À>ViÃÊ>ÀiÊÞÊvÀÊÕÃiÊÊV-
mercial installations. Do Not use MrSteam fragranc-
es in residential installations.
IN CASE OF EYE CONTACT: Rinse the eyes
immediately with plenty of water, also
under the eyelids, for at least 15 minutes. If eye
irritation persists: Get medical attention.
IN CASE OF SKIN CONTACT: Remove/Take off
immediately all contaminated clothing.
ii«Ê>Ü>ÞÊvÀÊi>Ì]Êë>ÀÃ]ÊiiVÌÀV>ÊÕÌiÌÃ]Ê
open flames such as candles and hot surfaces.
ÊÃ}°Ê
ii«Ê"ÕÌÊvÊÌiÊ,i>VÊvÊ`Ài°Ê
1ÃiÊÞÊë>À}ÊÌðÊ/>iÊ«ÀiV>ÕÌ>ÀÞÊ
measures against static discharge.
Ì>ÃÊ`i>ÌÕÀi`ÊiÌÞÊ>V°
ÊV>ÃiÊvÊvÀi\Ê1ÃiÊ"Ó]Ê`ÀÞÊViV>]Ê>VÊ
foam, and water spray for extinction.
Ü>ÞÃÊÃÌÀiÊÌiÊÀ-Ìi>ÊvÀ>}À>ViÃÊÊÃiVÕÀiÊ
V>Ì°Êii«ÊVÌ>iÀÊÌ}ÌÞÊVÃi`Ê>`Ê
store in a cool, dry and well-ventilated place.
ii«ÊÕÌÊvÊÀi>VÊvÊV`Ài°
/iÊÀ>ÊÃÞÃÌiÊ>ÃÊLiiÊv>VÌÀÞÊÃiÌÊÌÊ
deliver a suitable amount of fragrance into a typi-
cal sized commercial steam room. Start with the
AromaFlo dispensing pump volume at a very low
setting. Gradually increase the volume setting until
a comfortable fragrance level is reached. Do not
exceed the “
Recommended Setting
” indicated on
the pump volume.
iÛiÀÊÕÃiÊ>ÊÀ>Ê«Õ«ÊÊ,iÃ`iÌ>ÊÀÊ
Day Spa installation. Doing so may result in exces-
sive amounts of fragrance and personal injury.
Ê ÌÊ>ÌiÀÊÀÊ`vÞÊ>ÞÊÀ-Ìi>Ê«À`ÕVÌ°Ê
Doing so may result in a personal injury.
Never locate the caddy near or on the steam boil-
er. Doing so may result in fire, property damage or
personal injury
FLAMMABLE LIQUID AND VAPOR
Rinse skin with soap and water or shower. If skin
irritation persists, get medical attention.
IF SWALLOWED: Do not induce vomiting.
Rinse mouth thoroughly with water. If conscious,
give large amounts of water. If symptoms per-
sist, call a physician.
ÌÊvÀÊÕÃiÊÊ>VÀÞVÊÀÊvLiÀ}>ÃÃÊÀðÊ
Check with the room manufacturer to deter-
mine compatibility of these fragrances with
room construction materials.
Ê ÌÊ>ÌiÀÊÀÊ`vÞÊ>ÞÊÀ-Ìi>Ê«À`ÕVÌ°Ê
Doing so will void the warranty.
À-Ìi>ÊÀ>ÊvÀ>}À>ViÃÊÕÃÌÊLiÊ`Ã-
posed of as hazardous waste.
3
INSTALLER SECTION
AromaFlo Operation and Installation Instructions
®
Typical CU Commercial
Steambath Generator
Check
Valve
Steam Head
Steamline
Pressure Tube
Fragrance Container Cap
with Hole for Tubing
Fragrance Container
Fragrance
Caddy
Pump
Suction Tube
Pump Line
Cord
Steam Solenoid
with Outlet
AromaFlo System Overview
4
INSTALLER SECTION
AromaFlo Operation and Installation Instructions
®
All Drawings for Illustrative Purposes Only
5 -10 ft. optimal
51/2 ft. max
6 ft. max
2 ft. max
Steam
Generator
Steam
Pipe T
Check Valve
Suction
Hose
Pump Line Cord 120V
(to grounded outlet attached
to steam solenoid valve)
Fragrance
Caddy
Steam Solenoid
Valve Steam Head
(inside steam room)
Pressure Hose
Pump
General System Dimensions
PUMP SPECS
Dimensions: 7.5”W x 4.5”H x 4.5”D
Weight: 5 pounds
Motor voltage 120VAC, 50/60 Hz
Current Draw 0.5 Amps
5
INSTALLER SECTION
AromaFlo Operation and Installation Instructions
®
All Drawings for Illustrative Purposes Only
WARNING SIGN
The warning sign shall be posted in a conspicuous location
next to the steam room door.
PUMP LOCATION AND INSTALLATION
1. ii«ÊÌiÊÀ>Ê-ÞÃÌiÊ>Ü>ÞÊvÀÊi>Ì]Êë>ÀÃ]ÊiiVÌÀV>
outlets, open flames such as candles and hot surfaces.
2. Locate the Fragrance and Caddy to monitor the
consumption of fragrance and for easy replacement.
3. The AromaFlo System should not be installed in areas acces-
sible to children. A locked room is strongly recommended (i.e.
utility room)
4. The AromaFlo System is designed and intended for indoor
use only and is to be located indoors in a dry clean location
and not subject to moisture, condensation or similar high
humidity environments.
5. Do not install the AromaFlo System outdoors.
6. Do not install the AromaFlo System in a location where water
could freeze.
7. Do not install the AromaFlo System near corrosive materials
and chemicals. Installation in areas having high concentrations
of chlorine (such as pool equipment room) should be avoided.
8. Attach the AromaFlo Pump onto a secure vertical surface.
9. Use only non-sparking tools. Take precautionary
measures against static discharge.
6
INSTALLER SECTION
AromaFlo Operation and Installation Instructions
®
All Drawings for Illustrative Purposes Only
This room is equipped with an automatic
aromatic dispensing system. Leave Room
immediately if you have any adverse or
allergic reaction, including difficulty
breathing, or eye, nasal or throat irritation.
Mr. Steam
43-20 34th Street, Long Island City, New York 11101
800 767 8326
PN PUR100381 8/22
Installing the 90 degree T and Check Valve
1. For optimal results locate a brass 90 degree T (not provided)
in the steam supply line within 5-10 feet of the steam head. If
using copper tubing for steam lines, install a female 1/2 NPT
or 1/4 NPT reducing Tee in the steam line facing downward.
2. T must face downward as shown.
IMPORTANT NOTE:
Follow the installation instructions for the
steam pipeline in the MrSteam CU Series Steambath Generators
Installation and Operation Manual. Visit www.mrsteam.com to
download this document.
3. Install Check Valve into 90˚
T
/adaptor.
The Check Valve prevents excessive amounts of
fragrance from entering the steam line and steam room. Never
install the AromaFlo System without the Check Valve. Failure to
install the Check Valve may result in excessive fragrance delivery
into the steam room and cause dizziness and/or personal injury.
PRESSURE TUBE ASSEMBLY
For your convenience the pressure tube assembly is provided pre-
assembled. If additional tubing is needed please contact MrSteam
Technical service at 1-800-767-8326 or 1-800-727-8326.
Installation of Pressure Tube to the Pump
1. Insert the pressure tube through the hole of the pump tightening
nut and collar and firmly push the tube onto the tube holder.
2. Screw the pump tightening nut onto the pump and tighten the
nut by HAND only.
Installation of Pressure Tube to the 90˚ T
1.
Insert the pressure tube through the Check Valve tightening nut
and collar and firmly push the pressure tube onto the tube holder.
2. Screw the Check Valve tightening nut onto the Check Valve.
IMPORTANT NOTE: To prevent connection from leaking, insert
tubing holder completely into tubing until it reaches the bottom.
Lubricate the ID of the tubing as required with soap to facilitate
insertion.
IMPORTANT NOTE:
To prevent damage do not use tools to
tighten the nut.
WARNING
!
Steam Pipe (not supplied)
Adapter
(not supplied)
Check Valve
Tube Holder
Collar
Check Valve
Tightening Nut
Pressure Tube
Pump
Tightening
Nut
Collar
Tube Holder
Pump
90˚ Tee
(not supplied)
7
INSTALLER SECTION
AromaFlo Operation and Installation Instructions
®
All Drawings for Illustrative Purposes Only
SUCTION TUBE ASSEMBLY
For your convenience the suction tube assembly is provided
preassembled. If additional tubing is needed please
contact MrSteam Technical service at 1-800-767-8326 or
1-800-727-8326.
Installation of Suction Tube to the Pump
1. Insert the suction tube through the pump tightening nut
and collar and firmly push the tube onto the tube holder.
2. Screw the suction tube tightening nut to the
suction side of the pump.
IMPORTANT NOTE: HAND-TIGHTEN ONLY.
Installation of Suction Tube into the
Fragrance Container
1. Locate the “container cap” with the hole included
with the bottle of fragrance.
2. Insert the suction tube through the hole in the
container cap.
3. Remove the foot valve cap and insert the suction tube
through the cap. Push the suction tube onto the foot
valve. Tighten the cap onto the foot valve.
4. Unscrew the cap from the fragrance container
and discard.
5. Screw the cap onto the fragrance container.
6. Make sure the Foot Valve rests on the bottom of
the fragrance container.
IMPORTANT NOTE: To prevent connection from leaking,
insert tubing holder completely into tubing until it reaches the
bottom. Lubricate the ID of the tubing as required with soap
to facilitate insertion.
IMPORTANT NOTE: To prevent damage do not use tools to
tighten the nut.
Suction
Tube
Assembly
Tube Holder
Collar
Pump Tightening Nut
Suction Tube
Fragrance
Container
Cap with Hole
Foot Valve
Tightening Nut
Foot Valve
Fragrance
Container
Caddy
Pump
8
INSTALLER SECTION
AromaFlo Operation and Installation Instructions
®
All Drawings for Illustrative Purposes Only
Priming the Pump
1. Insure MrSteam fragrance container is full.
2. Insert a short piece of soft injector tube onto the tip of
the injector (see Fig. 1).
3. Insert the open end of the injector tube onto the
pressure valve (see Fig. 1).
4. Open the priming valve by turning the knob counter
clockwise one full revolution.
5. Draw liquid from the injector slowly and evenly.
Continue until the injector is full of liquid.
6. If you have drawn up the injector completely and no
liquid is in the injector, remove the injector tube from
the pressure valve.
7. Drain injector. Repeat steps until the injector is filled.
8. Save the fragrance injector as it may be needed when
new fragrances are used.
9. Close the priming valve completely by turning the
knob clockwise.
Failing to close the valve will result in
fragrance leaking from the priming port.
IMPORTANT NOTE: If an extended pressure tube is
special ordered then contact MrSteam Technical Service
(see page 20) for instructions for filling the pressure tube
with fragrance.
Priming Valve Knob
Soft Injector Tubing
Injector
CAUTION
!
Figure 1
9
INSTALLER SECTION
AromaFlo Operation and Installation Instructions
®
All Drawings for Illustrative Purposes Only
Electrical Connection of
Metering Pump
This AromaFlo system is
factory wired. If the power cord of the
AromaFlo pump is damaged it must be
replaced by the MrSteam service depart-
ment or similarly qualified personnel in
order to avoid an electric shock hazard.
All electrical connections to be made by a
licensed, qualified electrician. Disconnect
all power to the steam generator before
making power connections.
Electrical Box Assembly
To avoid possible electric
shock, the AromaFlo pump must be suitably
grounded according to National Electric
and local Codes. Disconnect all power
supplies before proceeding. Such wiring
should be done by a licensed electrician.
NOTE: Refer to the wiring diagram
above for all wiring connections
CAUTION
!
CU Steam Generator Digital 1 Control
CU AROMAFLO
PROBE
Steam Solenoid Valve
Digitl One Control
MrSteam Commercial
Steam Solenoid.
CAUTION
!Receptacle Faceplate
(supplied with AromaFlo)
Single Receptacle
(supplied with AromaFlo)
(2x4) NEMA Electrical Box
(supplied by others)
10
INSTALLER SECTION
AromaFlo Operation and Installation Instructions
®
All Drawings for Illustrative Purposes Only
VOLUME
Recommended
Setting
OPERATION
Powering Up the Pump
IMPORTANT NOTE: This step only needs to be performed during installation.
1. The pump needs to be turned on before it can be used
2. Ensure power is being supplied to the pump.
3. Press and hold the power button for 3 seconds.
The LED will turn solid green.
PUMP LED LIGHT: KEY:
Flashing Green LED Pump is OFF. Press and hold the power button for 3 seconds to turn the pump on.
Solid Green LED
Pump is on and has been activated from the in-shower control.
The LED will turn off each time the pump injects fragrance into the steam line.
No Light
Pump is OFF
The AromaFlo pump will inject a metered amount of fragrance into the steam line only when the
steam solenoid valve is open.
Adjusting the Amount of Fragrance Delivery
The AromaFlo system has been factory set to deliver a suitable amount of aromatic
fragrance into a typical sized steam room. Do not exceed the maximum setting.
Please contact the MrSteam Technical Service Department before changing this setting.
Contact the MrSteam Technical Service Dept. at (800) 76-STEAM (East coast)
or (800) 72-STEAM (West Coast) for assistance or additional information.
Increasing the settings may introduce excessive concentration of
fragrance into the steam room, resulting in a health hazard.
Fragrance
Setting Knob
Power Button
LED Light
AROMAFLO
®
L2210-2 Rev C
VOLUME
ON/OFF
Do not install or operate this product without read-
ing and following the supplied Installation and Operation Manual.
Additional copies of the manual can be found at www.mrsteam.com
or by contacting MrSteam at 1-800-767-8326
.
For Commercial Installations Only
CAUTION
!
CAUTION
!
Recommended
Setting
WARNING
!
Fully Assembled
The electrical outlet shown
is for AromaFlo Pump connection only. Make
no other connections to this outlet. Other
connections may result in circuit overload
CAUTION
!Electric Box with
Steam Solenoid
3 Conductor,
Grounding-type
Line Cord
AromaFlo
Metering Pump
MrSteam Commercial
Steam Solenoid.
11
INSTALLER SECTION
AromaFlo Operation and Installation Instructions
®
All Drawings for Illustrative Purposes Only
Pump fragrance delivery too much
or too little
The AromaFlo system has been factory
set to deliver a suitable amount of aromatic fragrance
into a typical sized steam room. Please contact the
MrSteam Technical Service Department before
changing this setting. See page 12 for instructions
on adjusting the amount of fragrance delivery.
Contact the MrSteam Technical Service Dept. at (800)
76-STEAM (East coast) or (800) 72-STEAM (West Coast)
for assistance or additional information.
ELECTRICAL SHOCK HAZARD. MrSteam
AromaFlo pumps are connected to 120V line voltage
and contain live electrical components. All installation
and service to be performed by qualified and licensed
electricians and plumbers only. Installation or service
by unqualified persons or failure to use MrSteam parts
may result in property damage or in a hazardous
condition.
TROUBLESHOOTING
Ê /"Ê6"Ê/,Ê-"]Ê-" -
NECT POWER TO PUMP BEFORE SERVICING
Pump does not prime
1. Check if voltage is available.
2. Check liquid level in fragrance container.
Replenish liquid, if necessary.
3. Check for air bubbles in the suction tube or
the pump head. To eliminate air bubbles see:
Priming Pump.
4. Check valves for contamination. Clean valves
if necessary.
5. Check foot valve in container for contamination.
Rinse foot valve under clean water.
Pump does not inject fragrance into
steam room
1. Check if voltage is available.
2. Check liquid level in fragrance container. Replenish
fragrance if necessary.
3. Check for air bubbles in the suction tube or the
pump head. To eliminate air bubbles see:
Priming Pump.
4. Check valves for contamination. Clean valves if
necessary.
5. Check foot valve in container for contamination.
Rinse foot valve under clean water.
6. Check the pressure tube for kinking or jamming.
Straighten or replace.
7. Check if fragrance is freely flowing through the
Check Valve when the metering pump is energized.
Apply compressed air through the Check Valve.
Attach the compressed air at the point of connection
of the pressure tube.
8.
Ensure the pump has been powered up. See page 12.
WARNING
!
WARNING
!
WARNING
!
12
INSTALLER SECTION
AromaFlo Operation and Installation Instructions
®
All Drawings for Illustrative Purposes Only
Check Valve (5 pcs.)
104240
Tube (per foot)
104255
Tube Connector
(3 pcs)
104250
Pump Head
104239
Tube Connector
(3 pcs)
104250
Tube (per foot)
104255
Foot Valve (2 pcs.)
104241
O-Ring Kit
(3 pcs.) 104275
Syringe (103983)
Priming Tube (6”) 104322
Caddy (104319)
REPLACEMENT PARTS
13
INSTALLER SECTION
AromaFlo Operation and Installation Instructions
®
All Drawings for Illustrative Purposes Only
Installing the Caddy
:
Box Contents: Tools required:
-Ì>iÃÃÊÃÌiiÊV>``ÞÊ UÊÀ`iÃÃÊ`ÀÊÜÌÊa Phillips bit
ÕÌ}ÊÃVÀiÜÃÊÓ®ÊÊ UÊiÛiÊÊ
ÃÌÀÕVÌÃÊÊ * Use only non-sparking tools.
Take precautionary measures
against static discharge
Locating the Caddy:
1. Place in a location that allows visual monitoring of the fragrances level.
2. Place in a location that allows for easy replacement of the fragrance
container.
3. The caddy should not be installed in areas accessible to children.
A locked room is strongly recommended (ie: utility room).
4. The maximm distance from the pump to the bottom of the caddy
is 6 feet (Diagram 1).
5. The caddy is designed and intended for indoor use only.
Do not install outdoors.
6. Do not install in an unheated location where water could freeze.
7.
Locate in an area where the ambient temperature does not exceed 88˚ F.
8. Never locate the caddy near or on the steam boiler. Doing so may result
in fire, property damage or personal injury
6 feet
max
Pump
Caddy
Fragrance
Top Screw
Hole
Bottom
Screw Keyhole
Bottom
Screw
2x4
Wall Stud
Diagram 1
Diagram 2
All diagrams for illustrative purposes only
Diagram 3
Drawing details removed for clarity
WARNING
!
Using a fragrance container that is not secured
in the caddy, or using a caddy that is not mounted may
result in spillage, excessively strong vapors or a fire hazard.
14
INSTALLER SECTION
AromaFlo Operation and Installation Instructions
®
All Drawings for Illustrative Purposes Only
All diagrams for illustrative purposes only
Diagram 5
Diagram 4
Mounting the Caddy on a Wall:
1. Use a level to make sure the caddy is level.
2. Use the two mounting screws provided to secure the caddy
to a wall stud (Diagram 2).
3. The fragrance and caddy are heavy. Failure to mount the caddy to a wall
stud in a secure manner may result in spillage, excessively strong vapors
or a fire hazard.
4. Install the lower screw first into a wall stud. Leave about 1/8” of the screw
sticking out above the surface. Lower the caddy onto the screw so the
caddy bottom keyhole rests securely on the screw.
5. Mounting screws have been provided. However, as construction materi-
als may vary, use other hardware (screws, anchors, etc. ) as required for
secure mounting. Test the caddy for secure mounting.
6.
Insert the fragrance container with the label facing outward so it is visible
through the caddy window (Diagram 4). The label contains important infor-
mation.
7. Connect the fragrance container to the pump according to instructions on
page 9 (Diagram 5).
8. Always keep the container in the caddy while it is connected to the dis-
pensing pump.
Mounting the Caddy on a Floor:
1. Use the two mounting screws provided to secure the caddy using the
two holes at the bottom of the caddy (Diagram 3).
2. Mounting screws have been provided. However, as construction materi-
als may vary, use other hardware (screws, anchors, etc. ) as required for
secure mounting. Test the caddy for secure mounting.
3. Insert the fragrance container with the label facing outward in a manner
it is visible through the caddy window (Diagram 4).
The label contains
important information.
4. Connect the fragrance container according to instructions on page 9
(Diagram 5).
5. Always keep the container in the caddy while it is connected to the dis-
pensing pump.
WARNING
!
Using a fragrance container that is not secured
in the caddy, or using a caddy that is not mounted may
result in spillage, excessively strong vapors or a fire hazard.
15
INSTALLER SECTION
AromaFlo Operation and Installation Instructions
®
All Drawings for Illustrative Purposes Only
OPERATOR SECTION
IMPORTANT NOTE:
As you follow these instructions, you will notice warning and caution symbols.
This blocked information is important for the safe and efficient installation and use of the fragrance and
caddy. These are types of potential hazards that may occur during installation and operation:
states a hazard may cause serious injury or death if precautions are not followed.
signals a situation where minor injury or product damage may occur if you do not follow instructions.
IMPORTANT NOTE:
This highlights information that is especially relevant to a problem-free installation.
WARNING
!
CAUTION
!
MrSteam Fragrance is Available in Two Fragrances:
FRAGRANCE PART NO. CONTAINER VOL.
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Eucalyptus CU-EUCALYPTUS 1 Gallon
A deeply refreshing aroma with cleansing effects,
eucalyptus may help open air passageways.
Lavender CU-LAVENDER 1 Gallon
A sweet, lightly floral scent, lavender may help
soothe anxiety with its calming and restorative properties.
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
The Safety Data Sheet provides comprehensive information about
MrSteam AromaFlo fragrances. Contact 1-800-767-8326 or go online at
www.mrsteam.com for a copy of the Safety Data Sheet.
THE AROMAFLO SYSTEM
FRAGRANCE DISPENSING PUMP
The AromaFlo’s state-of-the-art pump introduces
fragrance
into the steam pipe and into a commercial steam room.
MrSteam AromaFlo Fragrances
16
AromaFlo Operation and Installation Instructions
®
Û`ÊVÌ>VÌÊÜÌÊiÞiðÊ>ÞÊV>ÕÃiÊ`ÊiÞiÊÀÀÌ>Ì°Ê
Ingestion may cause irritation, nausea, vomiting.
6>«ÀÃÊ>ÞÊV>ÕÃiÊ`ÀÜÃiÃÃ]Ê>iÀ}VÊÀi>VÌÃ]Ê
difficulty breathing or skin irritation. If condition
persists get medical attention.
À-Ìi>ÊvÀ>}À>ViÃÊCU-EUCALYPTUS, CU-LAVENDER)
are only for use with the MrSteam AromaFlo
dispensing pump (part number CU-AROMAFLO).
Never use MrSteam fragrances in any other pump,
spray or dispensing device. The use of MrSteam fra-
grances in any other device may introduce excessive
concentration of fragrances into the steam room and
may cause personal injury.
/iÊÕÃiÊvÊ>ÞÊvÀ>}À>ViÃÊÌiÀÊÌ>ÊÀ-Ìi>ÊvÀ>-
grances with a MrSteam AromaFlo dispensing pump
may introduce excessive concentration of fragrances
into the steam room, resulting in personal injury.
WARNING
!
WARNING
!
FIRST AID
IMPORTANT NOTES:
/iÊ->viÌÞÊ>Ì>Ê-iiÌÊ«ÀÛ`iÃÊV«ÀiiÃÛiÊ
information about MrSteam fragrances. Contact
1-800-767-8326 or go online at www.mrsteam.com
for a copy of the Safety Data Sheet.
-Ìi>ÊÀ>ÊvÀ>}À>ViÃÊ>ÀiÊÞÊvÀÊÕÃiÊÊV-
mercial installations. Do Not use MrSteam fragranc-
es in residential installations.
IN CASE OF EYE CONTACT: Rinse the eyes
immediately with plenty of water, also
under the eyelids, for at least 15 minutes. If eye
irritation persists: Get medical attention.
IN CASE OF SKIN CONTACT: Remove/Take off
immediately all contaminated clothing.
ii«Ê>Ü>ÞÊvÀÊi>Ì]Êë>ÀÃ]ÊiiVÌÀV>ÊÕÌiÌÃ]Ê
open flames such as candles and hot surfaces.
ÊÃ}°Ê
ii«Ê"ÕÌÊvÊÌiÊ,i>VÊvÊ`Ài°Ê
1ÃiÊÞÊë>À}ÊÌðÊ/>iÊ«ÀiV>ÕÌ>ÀÞÊ
measures against static discharge.
Ì>ÃÊ`i>ÌÕÀi`ÊiÌÞÊ>V°
ÊV>ÃiÊvÊvÀi\Ê1ÃiÊ"Ó]Ê`ÀÞÊViV>]Ê>VÊ
foam, and water spray for extinction.
Ü>ÞÃÊÃÌÀiÊÌiÊÀ-Ìi>ÊvÀ>}À>ViÃÊÊÃiVÕÀiÊ
V>Ì°Êii«ÊVÌ>iÀÊÌ}ÌÞÊVÃi`Ê>`Ê
store in a cool, dry and well-ventilated place.
ii«ÊÕÌÊvÊÀi>VÊvÊV`Ài°
/iÊÀ>ÊÃÞÃÌiÊ>ÃÊLiiÊv>VÌÀÞÊÃiÌÊÌÊ
deliver a suitable amount of fragrance into a typi-
cal sized commercial steam room. Start with the
AromaFlo dispensing pump volume at a very low
setting. Gradually increase the volume setting until
a comfortable fragrance level is reached. Do not
exceed the “
Recommended Setting
” indicated on
the pump volume.
iÛiÀÊÕÃiÊ>ÊÀ>Ê«Õ«ÊÊ,iÃ`iÌ>ÊÀÊ
Day Spa installation. Doing so may result in exces-
sive amounts of fragrance and personal injury.
Ê ÌÊ>ÌiÀÊÀÊ`vÞÊ>ÞÊÀ-Ìi>Ê«À`ÕVÌ°Ê
Doing so may result in a personal injury.
Never locate the caddy near or on the steam boil-
er. Doing so may result in fire, property damage or
personal injury
FLAMMABLE LIQUID AND VAPOR
Rinse skin with soap and water or shower. If skin
irritation persists, get medical attention.
IF SWALLOWED: Do not induce vomiting.
Rinse mouth thoroughly with water. If conscious,
give large amounts of water. If symptoms per-
sist, call a physician.
ÌÊvÀÊÕÃiÊÊ>VÀÞVÊÀÊvLiÀ}>ÃÃÊÀðÊ
Check with the room manufacturer to deter-
mine compatibility of these fragrances with
room construction materials.
Ê ÌÊ>ÌiÀÊÀÊ`vÞÊ>ÞÊÀ-Ìi>Ê«À`ÕVÌ°Ê
Doing so will void the warranty.
À-Ìi>ÊÀ>ÊvÀ>}À>ViÃÊÕÃÌÊLiÊ`Ã-
posed of as hazardous waste.
17
OPERATOR SECTION
AromaFlo Operation and Installation Instructions
®
19
Locating the Caddy/Fragrance:
1. Place in a location that allows visual monitoring of the fragrances level.
2. Place in a location that allows for easy replacement of the fragrance container.
3. The caddy should not be installed in areas accessible to children. A locked room is strongly
recommended (ie: utility room).
4. The maximm distance from the pump to the bottom of the caddy is 6 feet (Diagram 1).
5. The caddy is designed and intended for indoor use only. Do not install outdoors.
6. Do not install in an unheated location where water could freeze.
7.
Locate in an area where the ambient temperature does not exceed 88˚ F.
8. Never locate the caddy near or on the steam boiler. Doing so may result in fire, property
damage or personal injury
Diagram 1
WARNING
!
Using a fragrance container that is not secured
in the caddy, or using a caddy that is not mounted may
result in spillage, excessively strong vapors or a fire hazard.
VOLUME
Recommended
Setting
Fragrance
Setting Knob
Power Button
LED Light
AROMAFLO
®
L2210-2 Rev C
VOLUME
ON/OFF
Do not install or operate this product without read-
ing and following the supplied Installation and Operation Manual.
Additional copies of the manual can be found at www.mrsteam.com
or by contacting MrSteam at 1-800-767-8326
.
For Commercial Installations Only
CAUTION
!
CAUTION
!
Recommended
Setting
OPERATION
Powering Up the Pump
IMPORTANT NOTE: This step only needs to be performed during installation.
1. The pump needs to be turned on before it can be used
2. Ensure power is being supplied to the pump.
3. Press and hold the power button for 3 seconds.
The LED will turn solid green.
PUMP LED LIGHT: KEY:
Flashing Green LED Pump is OFF. Press and hold the power button for 3 seconds to turn the pump on.
Solid Green LED
Pump is on and has been activated from the in-shower control.
The LED will turn off each time the pump injects fragrance into the steam line.
No Light
Pump is OFF
The AromaFlo pump will inject a metered amount of fragrance into the steam line only when the steam solenoid valve is open.
Adjusting the Amount of Fragrance Delivery
The AromaFlo system has been factory set to deliver a suitable amount of aromatic
fragrance into a typical sized steam room. Do not exceed the maximum setting.
Please contact the MrSteam Technical Service Department before changing this setting.
Contact the MrSteam Technical Service Dept. at (800) 76-STEAM (East coast)
or (800) 72-STEAM (West Coast) for assistance or additional information.
Increasing the settings may introduce excessive concentration of
fragrance into the steam room, resulting in a health hazard.
WARNING
!
All diagrams for illustrative purposes only
18
OPERATOR SECTION
AromaFlo Operation and Installation Instructions
®
All Drawings for Illustrative Purposes Only
mr
.steam®
Feel Good Inc.
®
www.mrsteam.com
Products, information and specifications are subject to change without notice.
Please call Technical Support at 1.800.76.STEAM (East Coast) or 1.800.72.STEAM (West Coast) for more information.
The model and serial number is printed on the data plate on the front of the steam bath generator.
Have this information available when contacting Technical Service.
mr.steam®
hello@mrsteam.com
I www.mrsteam.com
43-20 34th Street, Long Island City, NY 11101 TEL: 1 800 76 STEAM I 9410 S. La Cienega Blvd. Inglewood CA 90301 TEL: 1 800 72 STEAM
2020
© MrSteam and des., A Lifetime of Pleasure, AirTempo, AromaFlo, AudioWizard, AutoFlush, AutoSteam, Butler Package, ChromaSteam, Clean Steam...Every Time, Club Therapy, CT Day Spa,
Digital 1, Express Steam, Feel Good Inc., From Bathroom to Spa, HomeWizard, iButler, iGenie, iSpa Package, iSteam, iTempo, iTempo/Plus, Linear Steamhead, Making Wellness a Way of Life,
Music Therapy, My Steam, SmartSizing, Spa Package, Steam Genie, Steam on Demand, Steam in a Box, Steam@Home, SteamStart, SteamTherapy, Tala, Tala Bath & Body, Tempo, The Intelligent
Steambath, Valet Package, and Virtual Spa System are registered trademarks of MrSteam.
PUR103936 Rev 5.22
PUR100193 Rev 5.22
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

MrSteam AromaFlo System Installation & Operation Manual

Taper
Installation & Operation Manual

dans d''autres langues