Installation
Instructions
30", 36" and 48"
Professional Vent Hoods
Models:
ZV48T, ZV48S
ZV36T, ZV36S
ZV30T, ZV30S
2
Installation Instructions
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRICAL
SHOCK OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
A. Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact the
manufacturer.
B. Before servicing or cleaning unit, switch power off at
the service panel and lock service panel to prevent
power from being switched on accidentally. If the
service panel cannot be locked, fasten a tag or
prominent warning label to the panel.
AVERTISSEMENT
POUR RÉDUIRE LE RISQUE D’INCENDIE, DE
CHOC ÉLECTRIQUE OU DE BLESSURES, IL FAUT
OBSERVER LES REGLES SUIVANTES:
A. Utiliser cet appareil uniquement de la maniére
prévue par le fabricant. En cas de question, consulter
le fabricant.
B. Avant toute intervention ou nettoyage, couper
lalimentation électrique au disjoncteur et
verrouiller le panneau du disjoncteur pour éviter la
mise sous tension accidentelle. Sil nest pas possible
de verrouiller le panneau du disconcteur, attacher
un placard ou une étiquette trés visible au panneau.
For general ventilating use only. Do not use to exhaust
hazardous or explosive materials or vapors.
Structural framing, installation work and electrical
wiring must be done by qualified person(s). In
accordance with all applicable codes and standards
including fire-rated construction.
Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent back drafting. Follow
the heating equipment manufacturers guideline
and safety standards such as those published by the
National Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local
code authorities.
Local codes vary. Installation electrical connections
and grounding must comply with applicable codes.
In the absence of local codes, the vent should be
installed in accordance with National Electrical
Code ANSI/NFPA 70-1990 or latest edition.
CAUTION: To reduce risk of fire and to
properly exhaust air, be sure to duct air outside Do
not vent exhaust air into spaces within walls or ceilings
or into attics, crawl spaces, or garages.
PRUDENCEIl faut prendre soin dinstaller
un conduit vers lextérieur pour réduire le risque
dincendie et pouvoir évacuer lair correctement.
Il ne faut pas évacuer lair correctement. Il ne faut pas
évacuer lair dans lespace entre les parois dun mur,
un plafond ou un grenier, un espace sanitaire ou un
garage.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT - Save these instructions for
local inspectors use.
IMPORTANT - Observe all governing codes
and ordinances.
Note to Installer - Be sure to leave these instructions
with the Consumer.
Note to Consumer - Keep these instructions for
future reference.
Skill Level Installation of this vent hood requires
basic mechanical and electrical skills.
Completion time 1 to 3 hours.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not
covered under the Warranty.
CAUTION:
Due to the weight and size of these vent hoods and to
reduce the risk of personal injury or damage to the
product, TWO PEOPLE ARE REQUIRED FOR
PROPER INSTALLATION.
PRUDENCE
À cause du poids et de la taille de ces hottes et pour
reduire le risque de blessures et de dommages, IL FAUT
DEUX PERSONNES POUR FAIRE LINSTALLATION
CORRECTEMENT.
WARNING:
To reduce the risk of fire or electrical shock, do not
use this range hood with any external solid-state speed
control device. Any such alteration from original factory
wiring could result in damage to the unit and/or create
an electrical safety hazard.
AVERTISSEMENT
Pour réduire le risque dincendie ou de choc électrique,
il ne faut pas utiliser cette hotte avec un régulateur de
vitesse électronique externe. Toute modification de ce
type du branchement dusine peute endommager
lappareil ou créer un risque de choc électrique.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL
DUCTWORK.
3
Installation Instructions
PRODUCT DIMENSIONS
Model ZV48S With Straight Sides
Model ZV36S With Straight Sides
Model ZV30S With Straight Sides
Model ZV48T With Tapered Sides
Model ZV36T With Tapered Sides
Model ZV30T With Tapered Sides
CONTENTS
Product Dimensions ......................................................... 3
Installation Clearances .....................................................4
Optional Duct Cover Accessories .................................... 4
Installation Height, Duct Cover Accessories................... 5
Advance Planning ............................................................. 6
Power Supply .................................................................... 6
Duct Fittings...................................................................... 7
Tools and Materials Required .......................................... 8
Remove the Packaging ..................................................... 8
Parts Provided ................................................................... 9
Step 1, Determine Ductwork and Wiring Locations ....10
Step 2A, Install Hood Onto Wall ................................... 11
Step 2B, Install Hood Beneath Soffit ............................ 12
Step 3, Connect Ductwork ............................................. 13
Step 4, Connect Electrical ..............................................13
Step 5, Install Duct Covers ............................................. 13
Step 6, Install Motor ....................................................... 14
Step 7, Install Filters ....................................................... 14
Step 8, Install Implement Rods ..................................... 15
18"
47-15/16"
47-15/16"
12"
25"
18"
35-15/16"
35-15/16"
12"
25"
18"
29-15/16"
29-15/16"
12"
25"
18"
28"
25"
35-15/16"
12"
18"
22"
25"
29-15/16"
12"
18"
40"
25"
47-15/16"
12"
4
Advance Planning
INSTALLATION CLEARANCES
These vent hoods are designed to be installed onto a
wall or beneath a soffit or cabinet.
Install these hoods* 30" Min. to 36" Max. above the
cooking surface.
*These hoods may be installed 24" min. above a gas or
electric drop-in style cooktop. Always observe the 30"
to 36" clearance when installed over any professional
style cooktop or range.
In this installation the ductwork running from the top
of the hood will be concealed in the soffit or upper
cabinetry.
For this installation, a decorative duct cover is
available to conceal the ductwork running from
the top of the hood. Use of the duct cover requires
special consideration to the installation height above
the countertop.
Note: Clearances may vary due to type of cooking product and
local codes. Check with local inspectors to be sure standard is
applicable.
SOFFIT
Soffit Installation
30" MIN.
36" MAX.
Wall Mount Installation
30" MIN.
36" MAX.
OPTIONAL DUCT COVER
ACCESSORIES
Standard and Full-Width decorative duct covers are
available in 6" and 12" heights. Duct covers may be
stacked, in various combinations, to conceal the
ductwork running from the top of the hood to the
ceiling.
Before you begin, you should determine the
installation height of the hood and order the correct
size duct cover. The duct covers should be ordered at
the same time as the vent hood and be on site before
installation. Order the duct cover corresponding to
your model.
6" Duct Covers
Hood Model 6” Duct Cover Dimensions
ZV48T, ZV48S ZX48DC6 6"H x 19-11/16"W x 11-7/8"D
ZV36T, ZV36S ZX36DC6 6"H x 15-3/4"W x 11-7/8"D
ZV30T, ZV30S ZX36DC6 6"H x 15-3/4"W x 11-7/8"D
12" Duct Covers
Hood Model 12 Duct Cover Dimensions
ZV48T, ZV48S ZX48DC12 12"H x 19-11/16"W x 11-7/8"D
ZV36T, ZV36S ZX36DC12 12"H x 15-3/4"W x 11-7/8"D
ZV30T, ZV30S ZX36DC12 12"H x 15-3/4"W x 11-7/8"D
6" Duct Cover
12" Duct Cover
Standard Duct Covers
Optional 6"
or 12" Duct
Cover
Full-Width Duct Covers
6" Duct Covers
Hood Model 6 Duct Cover Dimensions
ZV48S ZX48FWDC6 6"H x 47-15/16"W x 11-7/8"D
ZV36S ZX36FWDC6 6"H x 35-15/16"W x 11-7/8"D
ZV30S ZX30FWDC6 6"H x 29-15/16"W x 11-7/8"D
12" Duct Covers
Hood Model 12 Duct Cover Dimensions
ZV48S ZX48FWDC12 12"H x 47-15/16"W x 11-7/8"D
ZV36S ZX36FWDC12 12"H x 35-15/16"W x 11-7/8"D
ZV30S ZX30FWDC12 12"H x 29-15/16"W x 11-7/8"D
5
Advance Planning
DETERMINE INSTALLATION HEIGHT, DUCT COVER ACCESSORIES
Tapered or Straight-Sided
Straight-Sided Hoods Hoods Only
w/ Standard w/ Full-Width
Duct Cover Duct Cover
*Possible
Actual Hood
Ceiling Installation 6" Duct 12" Duct 6" Duct 12" Duct
Height Height Covers Covers Covers Covers
7' 11" 35" 1 1
8' 0" 30" 1 1
8' 0" 36" 1 1
8' 1" 31" 1 1
8' 2" 32" 1 1
8' 3" 33" 1 1
8' 4" 34" 1 1
8' 5" 35" 1 1
8' 6" 30" 1111
8' 6" 36" 1 1
8' 7" 31" 1111
8' 8" 32" 1111
8' 9" 33" 1111
8' 10"34" 1111
8' 11"35" 1111
9' 0" 30" 2 2
9' 0" 36" 1111
9' 1" 31" 2 2
9' 2" 32" 2 2
9' 3" 33" 2 2
9' 4" 34" 2 2
9' 5" 35" 2 2
9' 6" 30" 1212
9' 6" 36" 2 2
9' 7" 31" 1212
9' 8" 32" 1212
9' 9" 33" 1212
9' 10"34" 1212
9' 11"35" 1212
10' 0" 30" 3 3
10' 0" 36" 1212
10' 1" 31" 3 3
10' 2" 32" 3 3
10' 3" 33" 3 3
10' 4" 34" 3 3
These vent hoods must be installed 30" min. to
36" max. above the standard 36" high cooking
surface. The exact hood installation height is
determined by the ceiling height.
1. Measure the exact ceiling height.
2. Review the chart at right to determine the
range of possible hood installation heights that
can be accomplished with one or more duct
covers.
3. Increase or decrease hood installation height to
accommodate the fixed 6" or 12" duct covers.
4. Duct covers may be stacked, in various
combinations, to reach ceiling heights.
*Based on 36" countertop height.
Note: Additional duct covers may be used to reach higher ceilings.
Installation Height
Ceiling Height
to Floor
Duct Covers
18" Hood
Height
Straight or Taper-Sided Hoods
6
Advance Planning
ADVANCE PLANNING
Ductwork Planning
These vent hoods are equipped for 10" round
ductwork. For best performance, use 10" round
ductwork on the 48" wide hoods. 30" and 36" hoods
may be transitioned to 8" round.
This hood may be vented vertically through upper
cabinets, soffit or ceiling. A duct transition piece is
supplied for vertical exhaust. Use locally supplied
elbows to vent horizontally through the rear wall.
Determine the exact location of the vent hood.
Plan the route for venting exhaust to the outdoors.
Use the shortest and straightest duct route possible.
For satisfactory performance, duct run should
not exceed 150 ft. equivalent length for any duct
configurations.
Refer to Duct Fittings chart to compute the
maximum permissible length for duct runs to the
outdoors.
Use metal ductwork only.
Install a wall cap or roof cap with damper at the
exterior opening. Order the wall or roof cap and any
transition needed in advance.
Wall Framing for Adequate Support
These vent hoods are heavy. Adequate structural
support must be provided. Hoods must be secured to
vertical studs in the wall.
It is strongly recommend that the vent hood with
duct cover be on site before final framing and wall
finishing. This will also help to accurately locate the
ductwork and electrical service.
Decorative Duct Covers:
Decorative duct covers, 6" and 12" high, are available to
fit all models. The duct cover conceals the ductwork
running from the top of the hood to the ceiling or
soffit. Stack one or more duct covers over the top of
the hood to reach your ceiling height.
POWER SUPPLY
IMPORTANT - (Please read carefully)
WARNING:
FOR PERSONAL SAFETY, THIS APPLIANCE MUST
BE PROPERLY GROUNDED.
AVERTISSEMENT – POUR DES
RAISONS DE SÉCURITÉ, CET APPAREIL DOIT
ÊTRE CORRECTEMENT MIS À LA TERRE.
Remove house fuse or open circuit breaker before
beginning installation.
Do not use an extension cord or adapter plug with
this appliance. Follow National electrical codes or
prevailing local codes and ordinances.
Electrical supply
These vent hoods must be supplied with 120V, 60Hz,
and connected to an individual, properly grounded
branch circuit, and protected by a 15 or 20 amp circuit
breaker or time delay fuse.
Wiring must be 2 wire with ground.
If the electrical supply does not meet the above
requirements, call a licensed electrician before
proceeding.
Route house wiring as close to the installation
location as possible on the back wall or ceiling.
Connect the wiring to the house wiring in
accordance with local codes.
Grounding instructions
The grounding conductor must be connected to
a ground metal, permanent wiring system, or an
equipment-grounding terminal or lead on the hood.
WARNING: The improper connection of
the equipment-grounding conductor can result in a
risk of electric shock. Check with a qualified electrician
or service representative if you are in doubt whether
the appliance is properly grounded.
AVERTISSEMENT
Le mauvais branchement du fil de mise à la terre peut
causer un choc électrique. En cas de doute, consulter
un électricien qualifié ou un technicien pour
déterminer si lappareil est à la terre.
7
Advance Planning
DUCT FITTINGS
Equivalent Quantity Total
Duct Piece Length* Used Length
10" round
to 8" round 5 ft.
Round, 1 ft.
straight (per foot
length)
3-1/4" x 10" 1 ft.
3-1/4" x 12" (per foot
straight length)
8" Dia. 17 ft.
90° elbow 10" Dia. 24 ft.
8" Dia. 10 ft.
45° elbow 10" Dia. 14 ft.
3-14" x 12" 15 ft.
3-1/4" x 10" 14 ft.
90° elbow
3-1/4" x 10" 8 ft.
3-1/4" x 12" 9 ft.
45° elbow
3-1/4" x 10" 33 ft.
3-1/4" x 12" 36 ft.
90° flat elbow
10" round transition
to 3-1/4" x 10" or
3-1/4" x 12" 9 ft.
3-1/4" x 10" or
3-1/4" x 12" to
10" round transition 6 ft.
10" round to 3-1/4" x 10" 16 ft.
3-1/4" x 12" transition 13 ft.
90° elbow
3-1/4" x 10" 9 ft.
3-1/4" x 12" to 10" round 8 ft.
transition 90° elbow
Round 8" Dia. 32 ft.
wall cap 10" Dia. 41 ft.
with damper
3-1/4" x 10" 24 ft.
3-1/4" x 12" wall cap 26 ft.
with damper
Round 8" Dia. 44 ft.
roof cap 10" Dia. 56 ft.
Use this chart to compute maximum
permissable lengths for duct runs to
outdoors.
Note:
Do not exceed maximum permissable
equivalent lengths!
Maximum recommended duct
length for these hoods: 150 feet
Flexible ducting:
If flexible metal ducting is used, all
the equivalent feet values in the table
should be doubled. The flexible
metal duct should be straight and
smooth and extended as much as
possible.
Do NOT use flexible plastic ducting.
Total Duct Run
Note:
Any home ventilation system, such as a
ventilation hood, may interrupt the proper flow of
combustion air and exhaust required by fireplaces,
gas furnaces, gas water heaters and other naturally
vented systems. To minimize the chance of interruption
of such naturally vented systems, follow the heating
equipment manufacturer’s guidelines and safety
standards such as those published by NFPA and ASHRAE.
*Actual length of straight duct plus duct
fitting equivalent. Equivalent length of duct
pieces are based on actual tests conducted
by GE Evaluation Engineering and reflect
requirements for good venting performance
with any ventilation hood.
Hoods Are Equipped
For 10" Round Duct
*Hoods are supplied with a 10"
round transition. A locally
supplied transition is required
for other sizes.
Note:
Outlet on top of hood is
8-1/8" x 8".
8
REMOVE THE PACKAGING
Lift out the wooden crossmember, as well as the top
protective carton.
Lift out the four L shaped polystyrene protection
profiles.
Remove the protection moldings around the smaller
carton box.
Remove the small box housing the motor.
Lift the hood out of the box.
CAUTION: Lift the hood by grasping
the outside edges of the inlet opening of the hood.
Do not lift the hood by the exhaust opening divider
damage will occur!
Remove the shipping screws holding the wood
mounting piece to the back side of the hood.
Set aside the wood mounting piece and screws
for later installation. Do not discard.
Remove the V shaped carton insert.
Remove the parts package from the V shaped
cardboard insert.
Remove the junction box cover and knockout.
Install the strain relief onto the back or top of the hood.
Remove all tape and packing material from the hood,
duct transition and motor.
Installation Preparation
TOOLS AND MATERIALS REQUIRED
(NOT SUPPLIED)
Pencil and tape measure
Pliers
Electric or battery operated drill
and 1/8", 3/8" bits
120V 60Hz. 15 or 20 Amp,
2-wire with ground. Properly
grounded branch circuit.
Key Hole Saw
Hammer
Wire cutter/stripper
Step ladder
Metal Snips
Saber saw
or Sawsall
Wire nuts
Phillips and flat
blade
screwdrdivers
Strain relief for
junction cover.
Spirit level
Flashlight
Safety glasses
10" round metal
duct, length to
suit installation.
Duct tape
Wood
Mounting
Support
Motor
Hood
Parts
Package
Shipping Carton
9
PARTS PROVIDED
Locate the parts packed with the hood.
2 Stainless Steel Grease Filters
(3 filters with 48" models)
Allen Wrench
For Implement Rods
Installation Preparation
Duct Transition
with Damper
2 Grease Filter Trays
(3 supports with 48" models.)
2 Implement Rods and 4 Stand-offs
Heat Lamp
(2 with 48" models)
HARDWARE
PACKAGE
Locate and check
contents. Screws
shown actual size.
6 Phillips head screws to
secure hood to the wood
support: (2 secured to
wood support)
4 Phillips head screws to
secure the transition to the
hood outlet on the top
2 (3/16") hollow wall anchors
with screws to secure hood
to the wall at the bottom
4 screws to secure the wood
support to the wall
POZIDRIV 3
1 safety screw and lock
washer, to secure the
blower: (screw is marked
with red or blue paint)
2 flat washers
for wall anchors
Wood Support
with Original Screws
10
Use a level to draw the cooktop centerline location.
Draw the line to ceiling height.
Measure desired distance from the bottom of the hood
to the cooking surface, 30" min. to 36" max.
Note: If you are installing the hood with duct covers, be sure to read
Using Duct Cover Accessories page 7. Exact installation height
may be determined by use of one or more duct covers.
Use a level to draw a straight horizontal pencil line
indicating the bottom of the hood.
From the line indicating the bottom of the hood,
measure 15-3/8" up and draw another line for the
location of the wood support. See illustration.
FOR VERTICAL (Straight Up) DUCTING:
Use a level to draw a centerline from the bottom of
the hood to ceiling or soffit.
If venting out the ceiling, extend the centerline
forward on the ceiling or soffit.
Locate the centerline of a 10-1/2" hole on the ceiling
or soffit by measuring 6" from the wall.
STEP 1 DETERMINE HOOD, DUCTWORK AND WIRING LOCATIONS
FOR DUCTING THROUGH REAR WALL:
Measure 9-7/8" above the marked line for the top of
the hood. At the centerline, mark location for a 10-1/2"
diameter hole.
House Wiring Location:
The junction box is fastened to the back of the hood
on the right side.
Installation Instructions
Alternate Knockout Locations
If the installation requires, the junction box can be
relocated from the back to the top of the hood. Remove
3 screws, align box to top knockout and secure with
original screws.
Remove junction box cover and knockout. Install strain
relief.
18-13/16" for 48" Models
12-13/16" for 36" Models
9-13/16" for 30" Models
Electrical
Area
8-3/8"
6-1/2"
18-1/16" for 48" Models
12-1/16" for 36" Models
9-1/16" for 30" Models
*Depending on
Hood width and
Installation Height.
Top of Hood
Bottom of Hood
18"
15-3/8"
Wood
Support
*House Wiring
Location
18"
9-7/8"
The recessed back side of the hood provides a large
area for the house wiring to exit the wall and be
routed to the rear knockout and junction box.
The location for the house wiring depends on the
installation height of the hood and the width of the
hood.
Remove junction box cover and knockout. Install
strain relief.
11
Installation Instructions
STEP 2A INSTALL HOOD ONTO WALL
Secure the wood support to 2 or more vertical studs, using
at least 2 of the 4 supplied long screws.
IMPORTANT: Screws must penetrate at least 1-1/2" into
vertical studs. Countersink screws into support.
Adjust depth of original mounting screws in the wood
support until they protrude 1/4" forward. This 1/4" gap will
provide clearance to hang the hood.
IMPORTANT: Framing must be capable of
supporting up to 150 lbs.
Test Duct Cover Fit
Place duct cover(s) over the top of the hood to check for gaps.
Adjust the hood up or down if necessary.
Install Bottom Mounting Screws
Drill 1/8" pilot holes into the two lower mounting holes.
Enlarge the holes if they did not enter studs to 3/8". Insert
anchors for wall fasteners into bottom holes. Remove anchor
screws and add flat washers provided. Drive screws into anchors
and tighten.
Install 4 additional screws through the back of the hood and
into the wood support.
IMPORTANT: Remove
shipping tape from
damper and check that
damper moves freely.
Duct
Transition
Top of
Hood
SKIP THIS STEP IF INSTALLING BENEATH A SOFFIT OR
CABINET, GO TO STEP 2B.
Locate at least 2 vertical studs at the wood support.
Center the supplied wood support, left to right and below the
15-3/8" marked line.
Place the transition piece over the hood exhaust and secure
with 4 screws provided.
Use duct tape to seal the connection. Check to be sure the
damper moves freely.
Hang Hood On Wood Support
Lift the hood and hold close to the installation location.
Route house wiring through the knockout and into the
junction box.
Place the hood over the wood support. Be sure the mounting
screws engage the keyhole slots in the back of the hood.
Tighten the screws.
WARNING: Continue to provide additional
support while the hood is mounted with only these 2 screws.
These screws will not support the weight of the hood. The hood
could fall resulting in damage or personal injury.
AVERTISSEMENT Continuez à fournir un soutien
additionnel pendant le montage de la hotte avec ces deux vis seulement. Ces
deux vis ne soutiendront pas le poids de la hotte. La hotte peut tomber,
occasionnant des blessures corporelles ou des dommages matériels.
Check to be sure the hood is level and centered.
Install Transition Onto Top of Hood
Centerline of
Installation
Space
30"
to
36"
Centerline of
Installation
Space
15-3/8"
30"
to
36"
Wood
Support
Note: The mounting
screws must remain in
their original shipping
location. These screws
are positioned to engage
the keyhole slots in the
back of the hood.
1/4"
Gap
Original Mounting
Screws as Shipped
12
Installation Instructions
STEP 2B Alternate Mounting Method
A”“B
Centerline to Stud Hood Width
and Keyhole Slots At the Top
ZV48T 19-9/16" 40"
ZV48S 23-9/16" 47-15/16"
ZV36T 13-9/16" 28"
ZV36S 17-9/16" 35-15/16"
ZV30T 10-9/16" 22"
ZV30S 14-9/16" 29-15/16"
INSTALL HOOD TO SOFFIT OR BENEATH CABINETS
SKIP THIS STEP IF USING WALL MOUNTING
METHOD
When necessary, the hood may be installed so that it is
supported by the soffit.
The soffit should be constructed with 2 x 4s.
Determine the installation location on the wall.
Continue the centerline forward on the bottom of the
cabinet or soffit.
The opening above the hood should allow for the 10"
round duct and clearance to slide the hood back
against the wall.
A
Requires 10-1/2" Min.
Opening For Ductwork
and Hood Installation
A
The 2 x 4 studs must be located as shown in the chart,
Dim. A. to accept mounting screws.
IMPORTANT: Soffit framing must be capable
of supporting up to 150 lbs.
Drill 1/8" pilot holes into the studs at the locations
shown in the top view illustration.
Install Transition Onto Top of Hood
Place the transition piece over the hood exhaust and
secure with 4 screws provided.
Use duct tape to seal the connection. Check to be sure
the damper moves freely.
Mount Hood onto Soffit or Cabinet
Note: If mounting to the underside of a cabinet with a
recessed bottom, install shims to fill the gap.
IMPORTANT: Remove
shipping tape from
damper and check that
damper moves freely.
Duct
Transition
Top of
Hood
Drive mounting screws into the studs until they
protrude 1/4". The 1/4" gap will provide clearance to
engage the keyhole slots in the top of the hood.
Lift hood to installation position. Locate house wiring
and route through the knockout (from the back or
top of the hood).
Lift hood onto mounting screws. Slide back against
the rear wall.
Tighten mounting screws.
IMPORTANT: For additional support and to
minimize vibration during operation, the hood must
be secured to the back wall. Use wall anchors to
fasten bottom back of hood to the wall.
1/4" Gap
Push Back
to Wall
Add Shims
If Bottom
Is Recessed
Back
Wall
Cabinet
or
Soffit
Engage Top
Keyhole Slots
2"
7-1/2"
A
C
B
2-9/16"
8"
8-1/8"
6"
Back of Hood
Top View
Front of Hood
13
Installation Instructions
STEP 3 CONNECT DUCTWORK
Install ductwork, making connections in direction of
airflow as illustrated.
Secure joints in ductwork with sheetmetal screws.
Wrap all duct joints with duct tape for an airtight seal.
Use duct tape to seal the flange connection. Reach
inside the hood and push the damper up to be sure it
moves freely.
STEP 4 CONNECT ELECTRICAL
STEP 5 INSTALL DUCT COVERS
Note: For easier handling, remove cardboard insert
after film is peeled off.
Remove protective film from duct covers. If more than
one duct cover is used, secure each piece together with
screws provided.
Place the duct cover(s) on top of the hood.
From inside the hood, secure the duct cover to the
top with the small Phillips head screws supplied with
the covers.
Verify that power is turned off at the source.
WARNING: If house wiring is not
2-wire with a ground wire, a ground must be provided
by the installer. When house wiring is aluminum, be
sure to use U.L. approved anti-oxidant compound
and aluminum-to-copper connectors.
AVERTISSEMENT Si le câblage
de la maison nest pas du type à deux fils avec un fil de
terre, linstallateur doit fournir un circuit de terre.
Quand les fils de la maison sont en aluminium, il
prendre soin dutiliser de la pâte antioxidation
approuvée par UL et des connecteurs pour
laluminium-cuivre.
Use wire nuts to connect incoming ground to green,
white to white and black to black.
Push wires into junction box and replace cover. Be
sure wires are not pinched.
White
Ground
Black
Remove
Junction Box
Cover
Insert Power
Conduit Thru
Strain Relief
and Tighten
Use UL Listed
Wire Nuts
A
B
C
Screw
Duct Tape
Over Seam
and Screw
Air Flow
Duct Tape
Over Transition
14
Installation Instructions
STEP 6 INSTALL MOTOR
From the inside of the hood, slip motor into the
attachment slot on the left.
Rotate motor upwards until it snaps into the spring
clip on the right.
Secure the motor to the hood with the machine
screw and lock washer. (Screw is marked with red or
blue paint.)
Plug connector into the motor.
IMPORTANT: Connector ends
are designed to mate only
one way. Match flat and
round connectors as shown.
Spring
Clip
Outlet
Attachment
Slot
Top
Attachment
Screw
Spring
Clip
STEP 7 INSTALL FILTERS
Place filter drip trays into the rear of the hood.
Insert the grease filter into the opening and drop
into the trays.
To remove the filters, grasp the handle, push the
filter up and lift out.
15
Installation Instructions
STEP 8 INSTALL IMPLEMENT
RODS
Use a flat blade screwdriver to install stand-offs into
the bottom of the hood.
Align implement rod to stand-offs with the screw hole
towards the inside of the hood. Secure the rod to the
stand-offs with the supplied Allen wrench.
Follow the same procedure on the opposite side.
Screw
Stand-offs
Into
Hood
Use Allen
Wrench to
Secure Rod
to Stand-offs
FINALIZE INSTALLATION
Install the supplied infrared bulb(s).
See the Owners Manual for instructions to test
operation.
16
Note: While performing installations described in this book,
safety glasses or goggles should be worn.
For Monogram
®
local service in your area, call
1.800.444.1845.
Note: Product improvement is a continuing endeavor at
General Electric. Therefore, materials, appearance and
specifications are subject to change without notice.
Pub. No. 49-80151-4
Dwg. No. 164D4290P108
10-06 JR
Printed in Italy
GE Consumer & Industrial
GE Appliances
General Electric Company
Louisville, KY 40225
ge.com
©2006 GE Company
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

GE Monogram ZV30T Guide d'installation

Catégorie
Hottes
Taper
Guide d'installation
Ce manuel convient également à

dans d''autres langues