KitchenAid KBPU182VSS00 Le manuel du propriétaire

Taper
Le manuel du propriétaire

Ce manuel convient également à

I_itchen_kid ®
OUTDOOR BUILT-IN POWER TMBURNER
For questions about features, operation/performance, parts, accessories or service, call: 1-800-422-1230
or visit our website at www.kitchenaid.com
In Canada, call for assistance, installation and service, call: 1-800-807-6777
or visit our website at www.KitchenAid.ca
BRULEUR HAUTE PUISSANCE ENCASTRE
P
POWER TMPOUR USAGE EXTERIEUR
Au Canada, pour assistance, installation ou service composez le 1-800-807-6777 ou visitez notre site Web a...
www.KitchenAid.ca
Table of Contents/Table des matieres ............................................................................. 4
iMPORTANT:
Save for local electrical inspector's use.
Installer: Leave installation instructions with the homeowner.
Homeowner: Keep installation instructions for future reference.
iMPORTANT :
_, conserver pour consultation par I'inspecteur local des installations _lectriques.
InstaHateur : Remettre les instructions d'installation au propri_taire.
Propri6taire : Conserver les instructions d'installation pour r_f_rence ult_rieure.
Model/Modele KBPU182VSS
W10243318A
OUTDOOR BUILT-IN POWER TMBURNER SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
_, DANGER
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open flame.
3. Open lid.
4. If odor continues, keep away from the
appliance and immediately call your
gas supplier or your fire department.
,_ WARNING
1. Do not store or use gasoline or other
flammable liquids or vapors in the
vicinity of this or any other appliance.
2. An LP cylinder not connected for use
shall not be stored in the vicinity of
this or any other appliance.
State of California Proposition 65 Warnings:
WARNING: This product contains a chemical known to the State of California to cause cancer.
WARNING: This product contains a chemical known to the State of California to cause birth defects or other reproductive harm.
In the State of Massachusetts, the following installation instructions apply:
m Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
the State of Massachusetts.
m If using a ball valve, it shall be a T-handle type.
m A flexible gas connector, when used, must not exceed 3 feet.
2
IMPORTANT: This Power TM burner is manufactured for outdoor use only. For Power TMburners that are to be used at elevations
above 2000 ft (609.6 m) orifice conversion is required. See "Gas Supply Requirements" section. It is the responsibility of the installer to
comply with the minimum installation clearances specified on the model/serial rating plate. The model/serial rating plate can be found
on the right-hand side panel.
Copies of the standards listed may be obtained from:
National Fire Protection Association CSA International
One Batterymarch Park 8501 East Pleasant Valley Rd.
Quincy, Massachusetts 02269 Cleveland, Ohio 44131-5575
iMPORTANT SAFETY iNSTRUCTiONS
WARNING: To reduce the risk of fire, electrical shock,
injury to persons, or damage when using the outdoor cooking
gas appliance, follow basic precautions, including the
following:
m Do not install portable or built-in outdoor cooking gas
appliances in or on a recreational vehicle, portable trailer,
boat or in any other moving installation.
m Always maintain minimum clearances from combustible
construction, see "Location Requirements" section.
m The outdoor cooking gas appliance shall not be located
under overhead unprotected combustible construction.
m This outdoor cooking gas appliance shall be used only
outdoors and shall not be used in a building, garage, or any
other enclosed area.
m Keep any electrical supply cord and fuel supply hose away
from any heated surfaces.
m Keep outdoor cooking gas appliance area clear and free
from combustible materials, gasoline and other flammable
vapors and liquids.
[] Do not obstruct the flow of combustion and ventilation air.
Keep the ventilation openings of the cylinder enclosure free
and clear from debris.
[] Inspect the gas cylinder supply hose before each use of the
outdoor cooking gas appliance. If the hose shows
excessive abrasion or wear, or is cut, it MUST be replaced
before using the outdoor cooking gas appliance. Contact
your dealer and use only replacement hoses specified for
use with the outdoor cooking gas appliance.
[] Visually check the burner flames. They should be blue.
Slight yellow tipping is normal for LP gas.
[] Check and clean burner/venturi tube for insects and insect
nest. A clogged tube can lead to fire under the outdoor
cooking gas appliance.
SAVE THESE
[] The LP gas supply cylinder to be used must be:
- constructed and marked in accordance with the
Specification for LP Gas Cylinders of the U.S. Department
of Transportation (DOT) or the National Standard of
Canada, CAN/CSA-B339, Cylinders, Spheres, and Tubes
for Transportation of Dangerous Goods; and Commission.
- provided with a listed overfilling prevention device.
- provided with a cylinder connection device compatible
with the connection for outdoor cooking gas appliances.
[] Always check connections for leaks each time you connect
and disconnect the LP gas supply cylinder. See
"Installation Instructions" section.
[] When the outdoor cooking gas appliance is not in use, the
gas must be turned off at the supply cylinder.
[] Storage of an outdoor cooking gas appliance indoors is
permissible only if the cylinder is disconnected and
removed from the outdoor cooking gas appliance.
[] Cylinders must be stored outdoors and out of the reach of
children and must not be stored in a building, garage, or
any other enclosed area.
[] The pressure regulator and hose assembly supplied with
the outdoor cooking gas appliance must be used. A
replacement pressure regulator and hose assembly
specific to your model is available from your outdoor
cooking gas appliance dealer.
[] Gas cylinder must include a collar to protect the cylinder
valve.
[] For appliances designed to use a CGA791 Connection:
Place a dust cap on cylinder valve outlet whenever the
cylinder is not in use. Only install the type of dust cap on
the cylinder valve outlet that is provided with the cylinder
valve. Other types of caps or plugs may result in leakage
of propane.
If the following information is not followed exactly, a fire
causing death or serious injury may occur.
[] Do not store a spare LP gas cylinder under or near this
outdoor cooking gas appliance.
[] Never fill the cylinder beyond 80 percent full.
iNSTRUCTiONS
TABLEOF CONTENTS
OUTDOOR BUILT-IN POWER TM BURNER SAFETY ................... 2
INSTALLATION REQUIREMENTS ................................................ 5
Tools and Parts ............................................................................ 5
Location Requirements ................................................................ 5
Product Dimensions .................................................................... 5
Cabinet Dimensions ..................................................................... 6
Electrical Requirements ............................................................... 9
Gas Supply Requirements ........................................................... 9
Gas Connection Requirements .................................................. 10
INSTALLATION INSTRUCTIONS ................................................ 11
Built-in Outdoor Power TM Burner Installation ............................ 11
Install Tank Tray for 20 Ib LP Gas Fuel Tank ............................. 11
GAS CONVERSIONS .................................................................... 15
Tools and Parts for Gas Conversion .......................................... 15
Conversion to a Local LP Gas Supply ....................................... 15
Conversion from LP Gas to Natural Gas ................................... 16
Check and Adjust the Burners ................................................... 18
USING YOUR OUTDOOR POWER TM BURNER ......................... 19
PowerTM Burner Use .................................................................. 19
LightingYour PowerTM Burner ................................................... 20
OUTDOOR POWER TM BURNER CARE ...................................... 21
General Cleaning ........................................................................ 21
TROUBLESHOOTING .................................................................. 22
ASSISTANCE OR SERVICE ......................................................... 22
In the U.S.A................................................................................ 22
Accessories ................................................................................ 22
In Canada ................................................................................... 22
WAR RANTY .................................................................................. 23
TABLEDES MATIERES
SI_CURITI_ DU BRULEUR HAUTE PUISSANCE ENCASTRI_
POUR USAGE EXTI_RIEUR POWER TM ....................................... 25
EXIGENCES D'INSTALLATION ................................................... 27
Outillage et pieces ...................................................................... 27
Exigences d'emplacement ......................................................... 27
Dimensions du produit ............................................................... 27
Dimensions du placard .............................................................. 27
Specifications electriques .......................................................... 30
Specifications de I'alimentation en gaz ..................................... 31
Exigences concernant le raccordement au gaz ........................ 32
INSTRUCTIONS D'INSTALLATION ............................................. 34
Installation du brQleur haute puissance d'exterieur
encastre Power TM ....................................................................... 34
Installation du chariot de bouteille de gaz propane
de 20 Ib....................................................................................... 34
CONVERSIONS DE GAZ .............................................................. 38
Outillage et pieces ...................................................................... 38
Conversion au gaz propane local .............................................. 38
Conversion du gaz propane au gaz naturel ............................... 39
Contr61e et reglage des brQleurs................................................ 41
UTILISATION DU BRULEUR HAUTE PUISSANCE POWER TM
D'EXTI_RIEUR ............................................................................... 42
Utilisation du brQleur haute puissance Power TM ........................ 42
Allumage du brQleur haute puissance Power TM ........................ 43
ENTRETIEN DU BRULEUR HAUTE PUISSANCE POWER TM
D'EXTI_RIEUR ............................................................................. 44
Nettoyage general ...................................................................... 44
DI_PANNAGE ................................................................................. 45
ASSISTANCE OU SERVICE ......................................................... 46
Accessoires ................................................................................ 46
GARANTIE .................................................................................... 47
INSTALLATION REQUIREMENTS
_?' i_: _ _._1:_
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools Needed
Tape measure Wrench or pliers
Small, flat-blade screwdriver Pipe wrench
Flat-blade screwdriver Scissors or cutting pliers
#2 and #3 Phillips screwdriver (to remove tiedowns)
Level Noncorrosive leak-
detection solution
Parts Supplied
Gas pressure regulator/hose assembly set for 11" WCP LP
gas (attached to manifold)
1 single-prong plug/2,085 mAmp transformer assembly
Convertible regulator set for 4" WCP Natural gas
Orifices for Natural gas conversion
LP gas fuel tank tray
Parts Needed
20 Ib LP gas fuel tank - approximately 18" (45.7 cm) height
and 12" (30.5 cm) diameter
[,,:}ca ::(_s Reqs,:: te_sle its
Select a location that provides minimum exposure to wind and
traffic paths. The location should be away from strong draft
areas.
Do not obstruct flow of combustion and ventilation air.
Clearance to combustible construction for built-in outdoor
Power TM burners:
A minimum of 24" (58 cm) must be maintained between the
sides and back and any combustible construction.
A zero clearance may be maintained below the cooking
surface and any combustible construction.
Ignition
A grounded, 3-prong outdoor GFI outlet is to be located inside
the island cabinet and to the left of the Power TM burner. See
"Electrical Requirements" section.
t A q
t
T-
B
L
® ©
A. 18_" (47.9 cm)
B. 10%" (27.0 cm)
C. 22 z_,,(58.1 cm)
D. 23%" (60.0 cm)
E. 22¼" (56.5 cm)
F. Manifold pipe
G. 3¼" (8.3 cm)
H. 191_,, (50.0 cm)
I.201_,, (53.2 cm)
Built-In Outdoor Power TM Burner Enclosure
This built-in outdoor Power TM burner is for installation in a built-in
enclosure constructed of combustible and noncombustible
materials. Some types of noncombustible materials could be
brick, firewall or steel. Some types of combustible materials
could be wood or laminate.
The enclosure for the built-in outdoor Power TM burner is to be a
minimum of 11" (28.0 cm) high x 20" (50.8 cm) deep x
19" (48.6 cm) wide.
Counterorsupportsurfacesmustbelevel.
TheinstallationofthisPowerTM burner must conform with local
codes or, in the absence of local codes, with either the National
Fuel Gas Code, ANSI Z223.1/NPFA 54, Natural Gas and Propane
Installation Code, CSA B149.1, or Propane Storage and Handling
Code, B149.2.
Copies of the standards listed may be obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
NOTE: The outdoor Power TM burner drops into the enclosure
opening and is supported by its side flanges. No bottom support
is needed.
The dimension chart and illustration below include cutout dimensions and minimum spacing requirements for all built-in outdoor
products. The illustration is for reference. The design of your cabinet layout can be personalized, but the dimensions for the cutouts and
minimum spacing must be followed.
C
E
E Gri!ls orrnent C
Refre_"
K
F
H A
Between 2 or more sets of Access Doors adjacent to each other:
K = 14" (35.6 cm) when 2 adjacent doors are opened to 90 degrees
K = 8" (20.3 cm) when 1 of the adjacent doors is opened to 90 degrees
Between a set of Access Doors and a Trash Drawer, Utility Drawer, Warming Drawer, Refrigerator, or Ice Maker:
K = 8" (20.3 cm) when 1 of the adjacent doors is opened to 90 degrees
Between a Trash Drawer, Utility Drawer, or Warming Drawer:
K = 3" (7.6 cm)
6
Cabinet Height and Depth Dimensions
With outdoor refrigerator
Grill with insulated jacket
Grill without insulated jacket
Dimension A Minimum
37" (94.0 cm)
361/2'' (92.7 cm)
351/2"(90.2 cm)
Dimension B Minimum
26" (66.0 cm)
27" (68.6 cm)
26" (66.0 cm)
Grill Size Dimension C Dimension D Dimension E
27" (68.6 cm) 29%" (75.2 cm) 10%" (27.3 cm) 227/8'' (58.1 cm)
36" (91.4 cm) 388/8'' (98.1 cm) 10%" (27.3 cm) 227/8'' (58.1 cm)
48" (121.9 cm) 50%" (128.6 cm) 103_'' (27.3 cm) 227/8'' (58.1 cm)
Cutout Dimensions - Built-in Grill with Insulated Jacket
Grill Size Dimension C Dimension D Dimension E
27" (68.6 cm) 33" (83.8 cm) 11%" (29.8 cm) 24" (61.0 cm)
36" (91.4 cm) 42" (106.7 cm) 11%" (29.8 cm) 24" (61.0 cm)
48" (121.9 cm) 54" (137.2 cm) 11%" (29.8 cm) 24" (61.0 cm)
Cutout Dimensions - Built-in Power TM Burner
Dimension C Dimension D Dimension E
193/8'' (49.2 cm) 103A'' (27.3 cm) 193A'' (50.2 cm)
Cutout Dimensions - Built-in Side Burner
Burner Position Dimension C Dimension D Dimension E
Front to Back 131/2'' (34.3 cm) 10%" (27.3 cm) 228/8'' (57.5 cm)
Side by Side 241/2'' (62.2 cm) 103_'' (27.3 cm) 167/8'' (42.9 cm)
Dimension C Dimension D Dimension E
131/2'' (34.3 cm) 10%" (27.0 cm) 221Vie'' (57.6 cm)
Cutout Dimensions - Built-in Refreshment Center
Dimension C Dimension D Dimension E
301/2'' (77.5 cm) 10%" (27.3 cm) 23" (58.4 cm)
Cutout Dimensions - Built-in Access Doors
Door Size Dimension F Dimension L*
18" (45.7 cm) 163/16"(41.1 cm) 11/2"(3.8 cm)
27" (68.6 cm) 251/8'' (63.8 cm) 11/2"(3.8 cm)
30" (76.2 cm) 281/8'' (71.4 cm) 11/2"(3.8 cm)
36" (91.4 cm) 341/8'' (86.7 cm) 11/2"(3.8 cm)
48" (121.9 cm) 461/8'' (117.2 cm) 11/2'' (3.8 cm)
*Dimension L is the minimum mounting surface area around the opening for mounting the optional door or drawers.
Dimension G Dimension H
24" (61.0 cm) 35W' (89.5 cm)
Cutout Dimensions - Outdoor Ice Maker
Dimension G Dimension H
18" (45.7 cm) 34" (86.4 cm) min. to 341/2'' (87.6 cm) max.
Cutout Dimensions - Built-in Warming Drawer
Warming Drawer Size Dimension J
24" (61.0 cm) 221/2'' (57.2 cm)
Dimension M Dimension L*
12W' (31.1 cm) 11/2'' (3.8 cm)
*Dimension L is the minimum mounting surface area around the opening for mounting the optional door or drawers.
Built-in Outdoor Grill Enclosure Ventilation for LP Gas:
An enclosure for an LP gas fuel tank is to be ventilated by
openings at both the top and lower levels of the enclosure.
If converting to LP gas, these vents are to be in the
enclosure:
An enclosure for use with an LP gas fuel tank for built-in
installation is to have at least one ventilation opening on an
exposed exterior side located within 5" (12.7 cm) of the top is to
be a minimum of 20 in.2 (129.0 cm2). One ventilation opening
within 1" (2.5 cm) of the bottom of the enclosure and the bottom
opening is to be a minimum of 10 in.2(64.5 cm_).All vent
openings are to be unobstructed. Every opening is to be a
minimum of 1/8"(0.32 cm) wide.
20 in.2(129.0 crn 2) rain.
ventimation both sides
1" (2.5 crn)
10 in? (64.5 crn 2)
ventilation both sides
5" (12.7 crn) max.
"_' (12.7 crn) max.
8
£:i',l@CI (;.a/_,.@;]!
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
Check with a qualified electrician if you are not sure whether the
Power TM burner is properly grounded.
A 120-volt, 60-Hz, AC-only, 15-amp, fused electrical supply is
required.
It is recommended that aseparate circuit servicing only this
Power TM burner be provided.
To avoid electrical shock, do not immerse cord or plugs in
water or other liquid.
Unplug from the outlet when not in use and before
cleaning. Allow to cool before putting on or taking off
parts.
Do not operate any outdoor cooking gas appliance with a
damaged cord, damaged plug, or after the appliance
malfunctions or has been damaged in any manner.
Contact the manufacturer for repair.
Do not let the cord hang over the edge of a table or touch
hot surfaces.
Do not use an outdoor cooking appliance for purposes
other than intended.
When connecting, first connect plug to the outdoor
cooking gas appliance then plug appliance into the outlet.
Use only a Ground Fault Interrupter (GFI) protected circuit
with this outdoor cooking gas appliance.
Do not remove the ground prong or use with an adapter
of 2 prongs.
The model/serial number rating plate is located on the right-hand
side panel. See the following illustration.
A
A. Model/serial number plate
Recommended Ground Method
The outdoor Power TM burner, when installed, must be electrically
grounded in accordance with local codes or, in the absence of
local codes, with the National Electrical Code ANSI/NFPA 70, or
Canadian Electrical Code, CSA C22.1.
Copies of the standards listed above may be obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
S ..............................
A ......................
A. 3 prong ground plug
B. 3-prong polarized type outdoor GFI outlet
C. Ground prong
"" _f ; _'_'_ /s /s ,/ _ ..................
Explosion Hazard
Use a new CSA international approved "outdoor"
gas supply line.
Securely tighten all gas connections.
if connected to LP, have a qualified person make sure
gas pressure does not exceed 11" (28 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes
and ordinances. In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas
Code ANSI Z223.1 - latest edition or CAN/CGA B149.1 - latest
edition.
IMPORTANT: The Power TM burner must be connected to a
regulated gas supply.
Refer to the model/serial rating plate for information on the type
of gas that can be used. If this information does not agree with
the type of gas available, check with your local gas supplier.
GasConversion:
NoattemptshallbemadetoconvertthePowerTM burner from
the gas specified on the model/serial rating plate for use with a
different gas type without consulting the serving gas supplier. The
conversion kits supplied with the Power TM burner must be used.
See "Gas Conversions" section for instructions.
Gas Pressure Regulator
The gas pressure regulator supplied with this Power TM burner
must be used. The inlet (supply) pressure to the regulator should
be as follows for proper operation:
LP Gas:
Set pressure: 11" (27.9 cm) WCP
Inlet (supply) pressure: 11" to 14" (27.9 cm to 35.5 cm) WCP
Natural Gas:
Set pressure: 4" (10.2 cm) WCP
Inlet (supply) pressure: 7' to 14" (17.8 cm to 35.5 cm)
WCP maximum.
Contact local gas supplier if you are not sure about the inlet
(supply) pressure.
Burner Requirements for High Altitude
Input ratings shown on the model/serial rating plate are for
elevations up to 2,000 ft (609.6 m).
For elevations above 2,000 ft (609.6 m), ratings are reduced at a
rate of 4% for each 1,000 ft (304.8 m) above sea level. Orifice
conversion is required. See "Assistance or Service" section to
order.
Gas Supply Line Pressure Testing
Testing above 1/2psi (3.5 kPa) or 14" (35.5 cm) WCP (gauge):
The Power TM burner and its individual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures greater than
1/2psi (3.5 kPa).
Testing below 1/2psi (3.5 kPa) or 14" (35.5 cm) WOP (gauge) or
lower:
The Power TM burner must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during any
pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2psi (3.5 kPa).
20 Ib LP Gas Fuel Tank
This Power TM burner is equipped for use with a 20 Ib LP gas fuel
tank (fuel tank not supplied). A gas pressure regulator/hose
assembly is supplied.
It is also design-certified by CSA International for local LP gas
supply or for Natural gas with appropriate conversion.
A
\
A. Gaspressure regulator/hose assembly
The 20 Ib LP gas fuel tank must be mounted and secured.
Door Style Tank Tray
1. Open cabinet doors.
2. Pull out the tank tray.
Tank tray
3. Place the 20 Ib LP gas fuel tank bottom collar into the
mounting hole in the tank tray.
4. Tighten the locking screw against the bottom collar of the
20 Ib LP gas fuel tank to secure.
B C
A. Locking screw
B. Mounting hole
C. Bottom collar
5. Slide tank tray back into the cabinet.
6. Close cabinet doors.
Local LP Gas Supply Conversion
Conversion must be made by a qualified gas technician. The
qualified gas technician shall provide the gas supply to the
selected Power TM burner location in accordance with the
National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest edition,
and local codes. For conversion to local LP, the convertible
regulator in the conversion kit supplied with the Power TM burner
must be used.
IMPORTANT: The gas installation must conform with local
codes, or in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 - latest edition. The qualified
LP gas technician shall provide the LP gas supply to the selected
Power TM burner location in accordance with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 and local codes.
Follow instructions for converting to local LP gas in the "Gas
Conversions" section.
C
A. New CSAInternational approved
"outdoor" flexiblegas supply line
B. Rear of Power TM burner
C. Tolocal LP gassupply
10
The gas supply line shall be equipped with an approved shutoff
valve. This valve should be located in the same area as the
Power TM burner and should be in a location that allows ease of
opening and closing. Do not block access to the shutoff valve.
The valve is for turning on or shutting off gas to the Power TM
burner.
A
B
A. Gas supply line
B. Shutoff valve "open" position
C. To Power TM burner
Natural Gas Conversion
Conversion must be made by a qualified gas technician. The
qualified Natural gas technician shall provide the Natural gas
supply to the selected Power TM burner location in accordance
with the National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest
edition, and local codes. For conversion to Natural gas, the
Natural gas conversion kit supplied with the Power TM burner
must be used.
IMPORTANT: The gas installation must conform with local
codes, or in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 - latest edition.
To convert to Natural gas, the Natural Gas Conversion Kit
supplied with the Power TM burner must be used. Follow
instructions for converting to Natural gas in the "Gas
Conversions" section.
_:::::::::::::::::::::) _ ,
C
A. New CSA International approved
"outdoor" flexible gas supply fine
B. Rear of Power TM burner
C. To Natural gas supply
The gas supply line shall be equipped with an approved shutoff
valve. This valve should be located in the same area as the
Power TM burner and should be in a location that allows ease of
opening and closing. Do not block access to the shutoff valve.
The valve is for turning on or shutting off gas to the Power TM
burner.
B
A. Gas supply line
B. Shutoff valve "open" position
C. To Power TM burner
INSTALLATION INSTRUCTIONS
Excessive Weight Hazard
Use two or more people to move and install side
burner.
Failure to do so can result in back or other injury.
1. Position the tank tray for 20 Ib LP gas fuel tank in the island
cabinet.
Unpack Power TM burner. Remove all packaging materials and
remove Power TM burner from carton.
Place Power TM burner into outdoor enclosure, but leave
enough room in back to connect to gas supply and electrical
single prong plug-in.
centerline of
tank tray
20%"
(52.4 crn)
18%"
21/4 It
(5.7 crn)
B
A. 8%2" (20.6 cm)
B. 16_" (41.1 cm)
11
2. Square the tank tray mounting brackets and mark the
mounting hole locations in the island base.
3. Remove the top nuts (4) from the tank tray assembly and lift
the tank tray off of the mounting brackets.
7.
The tank tray for the 20 Ib LP gas fuel tank must be adjusted
so that the bottom of the tank tray is %" (0.32 cm) above the
cabinet door opening and is level. The top nut on each of the
mounting brackets is to be loose. Turn the bottom nuts
counterclockwise to raise the tank tray and turn the bottom
nuts clockwise to lower the tank tray. When the tank tray is
level and slides in and out without touching the cabinet door
opening at the bottom or top with the 20 Ib LP tank installed,
tighten the top nuts against the adjustment flange.
4.
A. Top nut
B. Tank tray
C. Bottom nut
D. Bolt
E. Mounting bracket
Install the tank tray mounting brackets to the base or floor of
the island using the proper size and type of mounting
hardware (not supplied). Tighten mounting hardware.
A
g /
/
A. Screw (Use proper screw for island floor material.)
B. Lock washer
C. Flat washer
5. Pre-adjust each of the bottom nuts on the mounting brackets
to 3" (7.6 cm) from the base of the island to the top of the
nuts.
6. Remount the tank tray back onto the mounting brackets.
Replace the 4 top nuts but do not tighten.
A. 20 Ib LP gas fuel tank
B. Tank tray for 20 Ib gas fuel tank
C. Top nut (do not tighten)
D. Mounting bracket
B
A. Top nut loosened
B. Top nut tightened
NOTE: A bracket or shelf (not supplied) that is large enough
to keep a second 20 Ib LP gas fuel tank from being stored in
the storage area under the Power TM burner is required to be
mounted inside the island.
Make Gas Connection
Gas Connection to a 20 Ib LPGas FuelTank
Explosion Hazard
Use a new CSA international approved "outdoor"
gas supply line.
Securely tighten all gas connections.
if connected to LP, have a qualified person make sure
gas pressure does not exceed 11" (28 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
If converting to local LP or Natural gas, follow the instructions in
the "Gas Conversions" section.
IMPORTANT: A 20 Ib LP gas fuel tank must be purchased
separately.
IMPORTANT: The gas pressure regulator/hose assembly
supplied with the Power TM burner must be used. Replacement
gas pressure regulator/hose assembly specific to your model, is
available from your outdoor Power TM burner dealer.
12
To Install the 20 Ib LP Gas Fuel Tank:
1. Open cabinet doors.
2. Pull out the tank tray.
Tank tray
3. Place the 20 Ib LP gas fuel tank bottom collar into the
mounting hole in the tank tray.
4. Tighten the locking screw against the bottom collar of the
20 Ib LP gas fuel tank to secure.
Gas Connection to Natural Gas or Local LP Gas
Explosion Hazard
Use a new CSA International approved "outdoor"
gas supply line.
Securely tighten all gas connections.
if connected to LP, have a qualified person make sure
gas pressure does not exceed 11" (28 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
5=
B C
A. Locking screw
B. Mounting hole
C. Bottom collar
Screw the gas pressure regulator/hose assembly to the 20 Ib
LP gas fuel tank as shown. (To disconnect, turn off the gas
supply to the 20 Ib LP gas fuel tank, then unscrew the gas
pressure regulator/hose assembly from the 20 Ib LP gas fuel
tank as shown.
A
A.20 Ib LP gas fuel tank
B.Gaspressure regulator/hose assembly
6. Turn on the gas supply. Wait a few minutes for gas to move
through the gas line.
7. Test all connections by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.
8. Slide tank tray back into the cabinet.
9. Go to "Plug in Power TM Burner" in this section.
This installation must conform with local codes and ordinances.
In the absence of local codes, installations must conform with
either the National Fuel Gas Code ANSI Z223.1 - latest edition, or
CAN/CGA-B149.1 Natural Gas and Propane installation code.
Copies of the standards listed above may be obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
1. Make gas connections.
A combination of pipe fittings must be used to connect the
Power TM burner to the existing gas line.
If local codes permit, use an outdoor flexible stainless
steel tubing gas connector, design-certified by CSA
International, to connect the Power TM burner to the rigid
gas supply line. A %" diameter line is recommended.
Using a wrench to tighten, connect the gas supply to the
Power TM burner. Use pipe-joint compound on all non-
flared male threads. Do not kink or damage the flexible
connector when moving the Power TM burner.
Pipe-joint compounds suitable for use with LP gas must
be used. Do not use TEFLON ®ttape.
i/
i
C
A. New CSA International approved
"outdoor" flexible gas supply line
B. Rear of Power TM burner
C. To Natural gas or local LP gas supply
1-®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
13
2. Open the manual shutoff valve in the gas supply line. The 4. Gently slide the Power TM burner completely into the outdoor
valve is open when the handle is parallel to the gas pipe. enclosure.
3.
A. Closed valve
B. Open valve
Test all connections by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.
Plug in Power TM Burner
NOTE: This built-in outdoor Power TM burner comes with a large
2,085 mAmp power transformer/plug assembly for the Power TM
burner igniters. Follow the instructions for plugging in and
mounting the power transformer. Keep any electrical supply cord
away from any heated surfaces.
1. Plug the single-prong plug into the receptacle on the left
underside of the Power TM burner.
2.
3.
A. Single-prong plug
Locate or build a non-combustible surface inside the island
cabinet to mount the power transformer. It must be to the left
side of the Power TM burner at a minimum of 3" (7.6 cm) from
the side and 4" (10.2 cm) below the bottom of the Power TM
burner.
Mount the power transformer to the mounting surface using
4 #8 screws (not supplied) that are the proper type and length
for the transformer and the mounting surface. It must be
mounted with the wire for the single-prong plug upward or
toward the Power TM burner.
NOTE: The cord must be properly mounted with a cord
retention device so that its 3-prong plug will not touch the
ground when it is unplugged.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
5.
Plug 3-prong power cord plug into a grounded 3-prong GFI
outlet.
To avoid electrical shock, do not immerse cord or plugs in
water or other liquid.
Unplug from the outlet when not in use and before
cleaning. Allow to cool before putting on or taking off
parts.
Do not operate any outdoor cooking gas appliance with a
damaged cord, damaged plug, or after the appliance
malfunctions or has been damaged in any manner.
Contact the manufacturer for repair.
Do not let the cord hang over the edge of a table or touch
hot surfaces.
Do not use an outdoor cooking appliance for purposes
other than intended.
When connecting, first connect plug to the outdoor
cooking gas appliance then plug appliance into the outlet.
Use only a Ground Fault Interrupter (GFI) protected circuit
with this outdoor cooking gas appliance.
Do not remove the ground prong or use with an adapter
of 2 prongs.
Assemble Cooking Area
1. Lift off cover and grate and set aside.
A. Cover
B. Grate
14
2. Remove packing from around burner. 3. Remove plastic bags from grate and film from cover.
4. Reinstall grate.
5. Dispose of/recycle all packaging materials.
6. Go to the "Check and Adjust the Burners" section.
GAS CONVERSIONS
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
Phillips screwdriver
Pipe wrench
Adjustable wrench
10 mm socket and wrench
or 10 mm nut driver
Thin flat-blade screwdriver
Pliers
Pipe thread sealant
certified for LP gas
Parts supplied
Brass connector
Convertible regulator 4" W.C. Natural, 11" W.C. LP
Natural gas orifices
IMPORTANT: Gas conversions must be done by a qualified
installer. Before proceeding with conversion, shut off the gas
supply to the appliance prior to disconnecting the electrical
power.
This kit is designed for use from sea level up to 2000 ft elevation.
For higher elevations contact KitchenAid at 1-800-422-1230 in
the U.S.A. or call 1-800-607-6777 in Canada.
Explosion Hazard
Use a new CSA International approved "outdoor"
gas supply line.
Securely tighten all gas connections.
if connected to LP, have a qualified person make sure
gas pressure does not exceed 11" (28 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Installation of the regulator
1. Turn off the main gas supply valve.
2. Unplug Power TM burner or disconnect power.
3. Disconnect 20 Ib LP gas fuel tank (if present).
4. Turn off all burner control valves.
15
5. Use adjustable wrench to remove LP hose regulator from
brass elbow. Use adjustable wrench to remove brass elbow.
6.
7.
8.
9.
A. Manifold
B. Brass elbow
C. Rear of Power TM burner
D. Gas pressure regulator/hose assembly
Apply pipe sealant to the threads of the brass connector. Use
pipe thread sealant that is certified for use with LP gas.
Use adjustable wrench to install brass connector (supplied) to
manifold fitting.
NOTE: The arrow on the regulator must be pointing toward
the brass connector.
_m_ _'_I?',
iiiii!Y
Use pipe wrench to install the convertible regulator. Brass
cap will be facing up when tight.
A B
A, Brass connector
B. Convertible regulator
To set the appliance regulator for LP gas, use adjustable
wrench to remove the brass cap on the convertible regulator.
10. Examine the stem on the brass cap. The letters "NAT" should
be showing on the end of the plastic stem farthest away from
the brass cap.
11. Remove stem from cap, turn it over and snap stem back into
the cap so the letters "LP" are at the end of the stem farthest
away from the brass cap.
12. Use adjustable wrench to reinstall cap onto regulator.
Make Power TM Burner Connections
Connect Local LP Gas Supply
1. Use pipe wrench to connect certified 1/2"(1.3 cm) gas supply
pipe to inlet side of regulator from Fixed LP gas supply
according to local codes requirements. Use pipe thread
sealant that is certified for use with LP gas at connections
where required. There must be a certified manual shutoff
valve in the gas supply line near the Power TM burner for easy
access.
2. Turn on the gas supply to the Power TM burner.
3. Test all connections by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leaks found.
Record Conversion
In the last page of the Use and Care Guide, write "Converted to
Local LP Gas Supply." Also record the conversion date and the
technician/company that performed the conversion.
Installation of the regulator
1. Turn off the main gas supply valve.
2. Unplug Power TM burner or disconnect power.
3. Disconnect 20 Ib LP gas fuel tank (if present).
4. Turn off all burner control valves.
5. Use adjustable wrench to remove LP hose regulator from
brass elbow. Use adjustable wrench to remove brass elbow.
A .................
C
£
A. Manifold
B. Brass elbow
C. Rear of Power TM burner
D. Gaspressureregulator/hose
assembly
16
6,
7.
8,
9,
Apply pipe sealant to the threads of the brass connector. Use
pipe thread sealant that is certified for use with LP gas.
Use adjustable wrench to install brass connector (supplied) to
manifold fitting.
NOTE: The arrow on the regulator must be pointing toward
the brass connector.
Use pipe wrench to install the convertible regulator. Brass
cap will be facing up when tight.
A B
ii( 'iiiiiiiiD
A. Brass elbow
B. Convertible regulator
To make sure the regulator is set for Natural gas, use
adjustable wrench to remove brass cap on appliance
regulator.
10. Examine the stem on the brass cap. If the letters "NAT" are
not showing on the end of the plastic stem farthest away from
the brass cap, remove stem from cap, turn it over and snap
stem back into the cap so the letters "NAT" are at the end of
the stem farthest away from the brass cap.
11. Reinstall cap onto convertible regulator.
Change the Power TM burner orifices
1. Remove the Power TM burner grate.
2. Remove the wok ring. Twist counterclockwise, lift, and set
aside.
3,
4.
5,
Remove inner burner top ring from burner base.
Remove outer burner top ring from burner base.
A. Inner burner
B. Outer burner
C. Burner base
Remove the burner base.
a. Lift rear of burner to remove Iocator pin from Iocator hole.
b. Gently pull the burner base to the rear to disengage the
burner from the gas valves and openings.
IMPORTANT: The igniter is connected to the burner base.
Make sure the wires do not get pulled from the ignition.
c. Rotate burner base 90° and place in the bottom of the
burner box.
A. Igniter wire
17
6. Use a 10 mm socket and wrench or 10 mm nut driver to
remove the brass orifices from the gas valves.
A
\
7.
8.
9.
B
A. Inner burner
B. Outer burner
Use a 10 mm socket and wrench or 10 mm nut driver to
install the new 2.06 mm (inner burner) and 2.78 mm (outer
burner) brass orifices supplied with this kit.
NOTE: The number 2.06 and 2.78 are stamped on the orifices
for identification.
Replace the burner base. Insure the Iocator pin locks into the
Iocator hole.
A. Locator pin
Replace outer burner top ring, locate with the igniter slot over
the igniter.
A
J
A.Igniter
10. Replace inner burner top ring.
11. Replace the wok ring, locate the tabs to the slots and twist
clockwise to secure.
\
12. Replace burner grate.
Hook up to Natural gas and Leak Test
1. Use pipe wrench to connect certified 1/2"(1.3 cm) gas supply
pipe to inlet side of regulator from Natural gas supply
according to local codes requirements. Use pipe thread
sealant that is certified for use with LP gas at connections
where required. There must be a certified manual shutoff
valve in the gas supply line near the grill for easy access.
2. Turn on the gas supply to the grill.
3. Test all connections using an approved noncorrosive leak-
detection solution. Bubbles will show a leak. Correct any leak
found.
Record Conversion
The Power TM burner nameplate is located on the right-hand side
panel. With a permanent marker, check the box next to "Natural
gas" and mark through "LP - Propane."
In the last page of the Use and Care Guide, write "Converted to
Natural Gas." Also record the conversion date and the
technician/company that performed the conversion.
NOTE: Place LP gas parts in plastic parts bag for future use and
keep with pack containing literature.
........ .......... : +
The burners are tested and factory-set for most efficient
operation. However, variations in gas supply and other conditions
may make minor adjustments to low flame setting necessary.
It is recommended that a qualified person make burner
adjustments.
A. 4" (10.2 cm) for outer burner when set to "HI."
B. 3" (7.6 cm) for inner burner when set to HI."
Low Flame Adjustment
If flame goes out on the "LO" setting, the low flame setting must
be adjusted.
1. Turn off the valve and wait until burners are cool.
2. Light Power TM burner using information in the "Outdoor
Power TM Burner Use" section.
3. Turn burner to its lowest setting and remove knob.
4. Hold valve stem with pliers and insert a small flat-blade
screwdriver into the shaft.
5. Watch the flame and slowly turn the screwdriver
counterclockwise.
6. Adjust flame to minimum stable flame.
C
A. Valve stem
B. Small flat-blade screwdriver
C. Priers
7. Replace the control knob and turn off the burner.
8. Repeat steps 3 through 7 for each burner if needed.
18
USING YOUR OUTDOOR PO C-ER TMBURNER
Inspect the LP Gas Fuel Tank Supply Hose Wok Ring
Inspect the gas pressure regulator/hose assembly before each
use.
1. Open the cabinet door and slide 20 Ib LP gas fuel tank out.
2. Inspect the entire gas pressure regulator/hose assembly for
cuts, abrasions, or excessive wear.
3. If necessary, replace the gas pressure regulator/hose
assembly before using the Power TM burner.
Contact the dealer and use only replacement hoses specified for
use with the Power TM burner.
A
A. Gas pressure regulator/hose assembly
Prepare the Gas Supply
1. Remove outdoor Power TM burner cover.
2. Make sure the control knobs are all turned to the OFF
position.
Turn the Gas Supply On
NOTE: The Power TM burner can be used with or without the wok
ring. Without the wok ring, the heat zone expands to the edges of
the grate.
IMPORTANT: Before removing the Power TM burner grate, make
sure the gas supply is Off, all controls are in the Off position, and
the Power TM burner is cool.
To Remove the Wok Ring
1. Remove the Power TM burner grate.
2. Remove the wok ring. Twist counterclockwise, lift, and set
aside for future use with a Wok.
3. Replace burner grate.
To Replace the Wok Ring:
1. Remove the Power TM burner grate and set aside for future
use.
2. Set the wok ring into the notches in Power TM burner frame.
Twist clockwise to secure.
1. For outdoor Power TM burners using a 20 Ib LP gas fuel tank:
Slowly open the tank valve.
NOTE: If flow limiting device activates, your Power TM burner
may not light. If your Power TM burner does light, the flames
will be low and will not heat properly. Turn 20 Ib LP gas fuel
tank valve and all control knobs off and wait 30 seconds.
After shutting off the 20 Ib LP gas fuel tank, very slowly open
tank valve and wait 5 seconds before lighting.
2. For outdoor Power TM burners using gas supply source other
than 20 Ib LP gas fuel tank:
Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
The Power TM Burner, depending on your need can be used with:
The inner burner provides the lowest amount of heat for
cooking smaller quantities of food or liquid using smaller pots
and pans.
The outer burner provides high heat for cooking large
quantities of food or liquid using large pots and pans.
Both inner and outer burners together provide extra-high heat
for cooking extra-large quantities of food or liquid using
extra-large pots and pans.
3. Place Wok onto wok ring.
\
19
_,_ih_::ii_.... _ _i_ i_ow_i_:i'_¸_¸¸_¸_......._ _ _
Burn Hazard
Do not let the burner flame extend beyond the edge of
the pan.
Doing so can result in burns.
Manually lighting the Power TM burner
1. Remove the outdoor Power TM burner cover.
2. Remove the manual lighting extension (see following
illustration) and attach a match to the split ring.
Food Poisoning Hazard
Do not let food sit for more than one hour before or
after cooking.
Doing so can result in food poisoning or sickness.
1. Remove the Power TM burner cover. Do not light burners with
the cover on.
2. Do not lean over the Power TM burner.
3. Push in and turn the control knob for the inner or outer burner
to LITE/HI and hold in.
3. Strike the match to light it.
4. Guide the match to the burner you wish to light.
5= Do not lean over the Power TM burner. Push in and turn the
burner knob to LITE/HI for the burner you wish to light. The
burner will light immediately. When burner is lit, turn knob to
desired setting.
4. You will see the igniter glow. When burner is lit, release the
knob. Turn knob to desired setting.
5. Repeat for the other burner as needed.
IMPORTANT: If burner does not light immediately, turn the
burner knob to OFF and wait 5 minutes before relighting.
m
6. Repeat for each of the other burners as needed.
7. Remove match and replace manual lighting extension inside
its holder.
IM PORTANT:
If burner does not light immediately, turn the burner knob to OFF
and wait 5 minutes before relighting.
If any burners do not light after attempting to manually light them,
contact the KitchenAid Customer eXperience Center. See the
"Assistance or Service"
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

KitchenAid KBPU182VSS00 Le manuel du propriétaire

Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues