White Mountain Hearth Outdoor Linear Fireplace 60 (OLL60FP/SP) Le manuel du propriétaire

Catégorie
Cheminées
Taper
Le manuel du propriétaire

Ce manuel convient également à

OUTDOOR LINEAR
GAS FIREPLACE
MODELS:
OLL60FP12S(N,P)-2
OLL60SP12S(N,P)-2
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
WARNING
For Outdoor Use Only.
WARNING
If the information in these instructions are
not followed exactly, a re or explosion may
result causing property damage, personal
injury or loss of life.
WARNING
If not installed, operated and maintained in
accordance with the manufacturer's instructions,
this product could expose you to substances in
fuel or from fuel combustion which can cause
death or serious illness.
Installation and service must be performed
by a qualied installer, service agency or the
gas supplier.
DANGER
FIRE OR EXPLOSION HAZARD
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open ame.
3. If odor continues, leave the area
immediately.
4. After leaving the area, call your gas
supplier or re department.
Failure to follow these instructions could
result in re or explosion, which could cause
property damage, personal injury, or death.
WARNING
Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage. Read the installation, operating
and maintenance instructions thoroughly before
installing or servicing this equipment.
WARNING
Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any
other appliance.
An Propane-cylinder not connected for use
shall not be stored in the vicinity of this or any
other appliance.
DANGER
CARBON MONOXIDE HAZARD
This appliance can produce carbon monoxide
which has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed space
such as a camper, tent, car or home.
GAS-FIRED
INSTALLATION INSTRUCTIONS
AND OWNER’S MANUAL
Page 1
41309-2-0620Page 2
PROPANE GAS CYLINDER INFORMATION
DANGER - FLAMMABLE GAS UNDER PRESSURE.
LEAKING LP-GAS MAY CAUSE A FIRE OR EXPLOSION IF IGNITED
CAUSING SERIOUS BODILY INJURY OR DEATH.
CONTACT LP GAS SUPPLIER FOR REPAIRS, OR DISPOSAL OF THIS
CYLINDER OR UNUSED PROPANE-GAS.
WARNING - FOR OUTDOOR USE ONLY.*
DO NOT USE OR STORE CYLINDER IN A BUILDING,
GARAGE OR ENCLOSED AREA.
WARNING:
Know the odor of propane gas. If you hear, see
or smell leaking propane gas, immediately get
everyone away from the cylinder and call the
Fire Department. Do not attempt repairs.
Caution your propane gas supplier to:
- Be certain cylinder is purged of trapped
airpriortorstlling.
- Becertainnottooverllthecylinder.
- Becertaincylinderrequalicationdateis
checked.
Propane gas is heavier than air and may settle
in low places while dissipating.
Contact with the liquid contents of cylinder
will cause freeze burns to the skin.
Do not allow children to tamper or play with
cylinder.
When not connected for use, keep cylinder
valve turned off. Self contained appliances
shall be limited to a cylinder of 30 lb
capacity or less.
Do not use, store or transport cylinder where
it would be exposed to high temperatures.
Relief valve may open allowing a large
amountofammablegastoescape.
When transporting, keep cylinder secured in an
upright position with cylinder valve turned off.
WHEN CONNECTING FOR USE:
Use only in compliance with applicable codes.
Read and follow manufacturer’s instructions.
Consult manufacturer’s instructions
concerning the cylinder connection provided
with your appliance.
Be sure regulator vent is not pointing up.
Turn off all valves on the appliance.
Do not check for gas leaks with a match or
opename.Applysoapywateratareasmarked
“X”. Open cylinder valve. If bubble appears,
close valve and have propane gas service
personmakeneededrepairs.Also,check
appliance valves and connections to make sure
they do not leak before lighting appliance.
Light appliance(s) following manufacturer’s
instructions.
When appliance is not in use, keep the
cylinder valve closed.
DO NOT REMOVE, DEFACE, OR OBLITERATE THIS LABEL
*EXCEPT AS AUTHORIZED BY ANSI/NFPA 58.
DANGER.
Do not store a spare propane cylinder under or near a barbecue grill, or other heat sources.
NEVERllanpropanecylinderbeyond80%full:arecausingdeathorseriousinjurymayoccur.
Cylinder valve
hand wheel
Point of
connection
Liquid level
indicator
(optional)
relief valve
Pressure
Cylinder
X
X
X
X
X
41309-2-0620 Page 3
BEFORE YOU START
1. Read the safety information on pages 5 to 6.
2. What to consider before installing. See Page 12.
3. Water drainage is required. See page 13. Optional drain tray
available.
4. Where are you going to install the unit? See pages 12 to 14.
5. Frame the opening. See pages 9 to 11 and 15 to 16.
6. Installthereplace.Seepages15to17.
7. Connecttheelectricity.Seepages17and27.
8. Connectthegas.Seepage18to20.
9. Install the crushed glass. See page 23.
10. Lightthereplaceandtroubleshoot.Seepages24and29.
11. Showthehomeownerhowtooperatethereplace.See
page 26.
12. Show the homeowner how to do the basic maintenance. See
page28.
Tools Needed:
(1)-1/8-inchAllenWrench
(2)-Adjustalbewrencheswithrangeof1-inchforgasconnection
(2)-Adjustablepipewrenches
(1) - Phillips Screwdriver
CARTON CONTENTS
INDEX
NO.
DESCRIPTION
QUANTITY
SUPPLIED
OLL60FP OLL60SP
1 Glass Panel 1 2
2 Non-Combustible Panel - Top 1 2
3 Non-Combustible Panel - Side 2 4
4 Envelope 1 1
5 Nailing Flange 4 8
6 Receptacle 1 1
7 Cover Plate 1 1
8 Conduit Connector 1/2-in. 1 1
9 AABattery 1 1
10 Burner Service Support 2 2
See Parts Lists on pages 31 to 34 for ordering replacement parts.
Do not order batteries, bolts, screws, washers or nuts. They are
standard hardware items and can be purchased at any local
hardware store.
1
6
2
3
5
7
4
8
9
10
HARDWARE PACK CONTENTS
1-1/4” PHILLIPS SELF-DRILLING SCREW
(
)
6 - OLL60FP12S(N,P))
(12 - OLL60SP12S(N,P)
#10-32 X ½”
ST
AINLESS HEX HEAD SCREW
(8 - OLL60FP12S(N,P))
(16 - OLL60SP12S(N,P))
41309-2-0620Page 4
TABLE OF CONTENTS
Propane Gas Cylinder Information .................................................................................................2
Before You Start .............................................................................................................................3
Table Of Contents ..........................................................................................................................4
Important Safety Information ..........................................................................................................5
Safety Information For Users Of Propane Gas ..............................................................................6
ProductSpecications ...................................................................................................................7
Accessories ....................................................................................................................................7
Introduction ....................................................................................................................................8
Combustible Materials ...................................................................................................................9
Clearances ............................................................................................................................. 9 - 10
Fireplace Dimensions ..................................................................................................................11
Planning Installation ............................................................................................................. 12 - 14
FireplaceFramingAndInstallation ....................................................................................... 15 - 23
Lighting Instructions .....................................................................................................................24
Main Burner Flame Characteristics ..............................................................................................25
OperationInstructions/FlameAppearance .................................................................................26
Wiring ...........................................................................................................................................27
Maintenance ................................................................................................................................28
Troubleshooting ...........................................................................................................................29
Master Parts Distributor List .........................................................................................................30
How To Order Repair Parts ..........................................................................................................30
OLL60FP Parts List ......................................................................................................................31
OLL60FP Parts View ....................................................................................................................32
OLL60SP Parts List .....................................................................................................................33
OLL60SP Parts View ...................................................................................................................34
Warranty Terms ............................................................................................................................35
SECTION PAGE
41309-2-0620 Page 5
IMPORTANT SAFETY INFORMATION
DANGER: Indicates a hazardous situation which, if not
avoided,willresultindeathorseriousinjury.
WARNING: Indicates a hazardous situation which, if not
avoided,couldresultindeathorseriousinjury.
CAUTION: Indicates a hazardous situation which, if not
avoided,couldresultinminorormoderateinjury.
NOTICE:Addressespracticesnotrelatedtopersonalinjury.
WARNING
Do not place debris, logs, or other articles in replace during
operation.
WARNING
Any modication to controls can be dangerous. Improper
installation or use of the gas log set can cause serious injury or
death from re, burns, explosion or carbon monoxide poisoning.
WARNING
Make a periodic visual check of burners. Clean and replace
damaged parts.
DANGER
Children and adults should be alerted to the hazard of high
surface temperature and should stay away to avoid burns or
clothing ignition.
DANGER
Young children should be carefully supervised when they are
in the same area with the replace.
DANGER
Clothing or other ammable materials should not be hung from
the replace, or placed on or near the replace.
DANGER
Keep the replace area clear and free from combustible
material, gasoline and other ammable vapors and liquids.
Installer: Please leave these instructions with the owner for
future reference
This unit complies with ANSI Z21.97/CSA 2.41 for Outdoor
Gas Fireplaces.
Installation and repair should be done by a QUALIFIED SERVICE
PERSON. This replace should be inspected before use and at
least annually by a professional service person. More frequent
cleaning may be required due to insects, pollen build up, dust,
etc. It is imperative that the control compartments, burners,
and circulating air passageways of the replace be kept clean.
During manufacturing, fabricating and shipping, various
components of this replace are treated with certain oils,
lms or bonding agents. These agents are not harmful, but
may produce annoying smoke and smells as they are burned
off during initial operation of the replace. This is a normal
temporary occurrence.
Follow all local codes regarding installation, combustion
and ventilation air or in the absence of local codes follow the
National Fuel Gas Code ANSI Z223.1 (US installation), or CAN/
CGA-B149, installation Code (Canada installation).
Inspect the burner at least once a year.
Keep burner and control compartment clean.
DO NOT use this replace if any part has been under water.
Immediately call a qualied service technician to inspect
the replace and to replace any part of the control system
and any gas control which has been under water.
Any guard or other protective device removed for servicing
the appliance must be replaced prior to operating the
appliance.
41309-2-0620Page 6
SAFETY INFORMATION FOR USERS OF PROPANE GAS
Propane is a ammable gas which can cause res and explo-
sions. In its natural state, propane is odorless and colorless.
You may not know all the following safety precautions which
can protect both you and your family from an accident. Read
them carefully now, then review them point by point with the
members of your household. Someday when there may not
be a minute to lose, everyone’s safety will depend on knowing
exactly what to do. If, after reading the following information,
you feel you still need more information, please contact your
gas supplier.
PROPANE GAS WARNING ODOR
If a gas leak happens, you should be able to smell the gas
because of the odorant put in the Propane Gas.
That's your signal to go into immediate action!
Do not operate electric switches, light matches, use your phone.
Do not do anything that could ignite the gas.
Get everyone out of the building, vehicle, trailer, or area. Do
thatIMMEDIATELY.
Close all gas tank or cylinder supply valves.
Propane Gas is heavier than air and may settle in low areas
such as basements. When you have reason to suspect a gas
leak, keep out of basements and other low areas. Stay out until
reghtersdeclarethemtobesafe.
Use your neighbor’s phone and call a trained Propane Gas
servicepersonandtheredepartment.Eventhoughyoumay
not continue to smell gas, do not turn on the gas again. Do not
re-enter the building, vehicle, trailer, or area.
Finally, lettheservicemanandreghterscheckforescaped
gas. Have them air out the area before you return. Properly
trained Propane Gas service people should repair the leak,
thencheckandrelightthegasreplaceforyou.
NO ODOR DETECTED - ODOR FADE
Some people cannot smell well. Some people cannot smell
the odor of the chemical put into the gas. You must nd out if
you can smell the odorant in propane. Smoking can decrease
your ability to smell. Being around an odor for a time can affect your
sensitivity or ability to detect that odor. Sometimes other odors in
the area mask the gas odor. People may not smell the gas odor or
their minds are on something else. Thinking about smelling a gas
odor can make it easier to smell.
The odorant in Propane Gas is colorless, and it can fade under
some circumstances. For example, if there is an underground
leak,themovementofthegasthroughsoilcanltertheodorant.
OdorantsinPropaneGasalsoaresubjecttooxidation.Thisfading
can occur if there is rust inside the storage tank or in iron gas pipes.
The odorant in escaped gas can adsorb or absorb onto or into
walls, masonry and other materials and fabrics in a room. That will
take some of the odorant out of the gas, reducing its odor intensity.
Propane Gas may stratify in a closed area, and the odor intensity
could vary at different levels. Since it is heavier than air, there may
bemoreodoratlowerlevels.Alwaysbesensitivetotheslightestgas
odor. If you detect any odor, treat it as a serious leak. Immediately
go into action as instructed earlier.
SOME POINTS TO REMEMBER
Learn to recognize the odor of Propane Gas. Your local Propane
Gas Dealer can give you a “Scratch and Sniff” pamphlet. Use
ittondoutwhatthepropaneodorsmellslike.Ifyoususpect
that your Propane Gas has a weak or abnormal odor, call your
Propane Gas Dealer.
• Ifyouarenotqualied,donotlightpilotlights,performservice,
ormakeadjustmentstoreplacesonthePropaneGassystem.
Ifyouarequalied,consciouslythinkabouttheodorofPropane
Gas prior to and while lighting pilot lights or performing service
ormakingadjustments.
Sometimes a basement or a closed-up house has a musty
smell that can cover up the Propane Gas odor. Do not try to
lightpilotlights,performservice,ormakeadjustmentsinan
area where the conditions are such that you may not detect
the odor if there has been a leak of Propane Gas.
Odor fade, due to oxidation by rust or adsorption on walls of
new cylinders and tanks, is possible. Therefore, people should
be particularly alert and careful when new tanks or cylinders
are placed in service. Odor fade can occur in new tanks, or
reinstalledoldtanks,iftheyarelledandallowedtosettoo
longbeforerelling.Cylindersandtankswhichhavebeenout
of service for a time may develop internal rust which will cause
odor fade. If such conditions are suspected to exist, a periodic
sniff test of the gas is advisable. If you have any question
about the gas odor, call your Propane Gas Dealer. A peri-
odic sniff test of the Propane Gas is a good safety measure
under any condition.
If, at any time, you do not smell the Propane Gas odorant and
you think you should, assume you have a leak. Then take the
same immediate action recommended above for the occasion
when you do detect the odorized Propane Gas.
If you experience a complete “gas out,” (the container is under
no vapor pressure), turn the tank valve off immediately. If the
container valve is left on, the container may draw in some air
throughopeningssuchaspilotlightorices.Ifthisoccurs,some
new internal rusting could occur. If the valve is left open, then
treatthecontainerasanewtank.Alwaysbesureyourcon-
tainer is under vapor pressure by turning it off at the container
beforeitgoescompletelyemptyorhavingitrelledbeforeitis
completely empty.
41309-2-0620 Page7
PRODUCT SPECIFICATIONS
DECORATIVE CRUSHED GLASS
Required Decorative Crushed Glass Media Kits (10 Sq. Ft. Required for Burner and LED Lighting)
Model Description
DG1CLF* Clear Frost
DECORATIVE CRUSHED GLASS (FOR ACCENT ONLY)
Model Description
DG1BKP* Black Polished
DG1BUC* Blue Clear
*Clear Frost Decorative Crushed Glass is required. Decorative Glass Droplets cannot be substituted for crushed glass. One bag
of crushed glass covers 1 sq. ft. Enough crushed glass to cover 10 sq. ft. is required. Glass colors may be mixed. The maximum
amount of Crushed Decorative Glass allowed is 10 bags. Transparent and Translucent crushed glass will allow LEDs to better shine
through.
DECORATIVE GLASS DROPS & DROPLETS (MAY BE USED IN ADDITION TO CRUSHED GLASS AS AN ENHANCEMENT)
Model Description
DG1NXS 1-in. Decorative Glass Drops - Onyx Solid
DG1RYC 1-in. Decorative Glass Drops - Ruby Clear
DG1TZC 1-in. Decorative Glass Drops - Topaz Clear
DG1AB 1/2-in.DecorativeGlassDroplets-AquaBlue
DG1GC 1/2-in. Decorative Glass Droplets -Glacier Ice
DG1SL 1/2-in. Decorative Glass Droplets -Sangria Luster
Note: Decorative Glass Droplets may be added on top of the crushed glass as an enhancement. Decorative Glass Droplets must not
beplacedintheburnerame.SeeCrushedGlassInstallation,Page22.DonotaddmorethanonebagofDecorativeglassdroplets.
ACCESSORIES
Model Description
DT48LSS StainlessSteelDrainTray-(Fits48and60-in.replaces)
WD60LSS StainlessSteelWeatherDoor-60-in(ordertwoforsee-throughreplaces)
WG60LT1 DeectorGlassforWindyApplications-60-in(ordertwoforsee-throughreplaces)
35829 Natural to Propane Conversion Kit
35830 Propane to Natural Conversion Kit
ACCESSORIES
Model Number OLL60FP12 (Natural) OLL60FP12 (Propane) OLL60SP)12 (Natural) OLL60SP12 (Propane)
Input BTU/Hr Maximum 65,000 65,000 65,000 65,000
Input BTU/Hr Minimum 39,000 37,000 39,000 37,000
KWH Maximum 19.05 19.05 19.05 19.05
KWH Minimum 11.43 10.84 11.43 10.84
Orice #14 #41 #14 #41
AirShutterSetting 1/16" Open Full Open 1/16" Open Full Open
Gas Inlet Shut-Off Valve Pipe
1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT
GAS SUPPLY PRESSURES (INCHES WATER COLUMN)
Gas Type Maximum Minimum Manifold
Natural 14 4.5 4.5
Propane 14 11 11
41309-2-0620Page8
INTRODUCTION
Hearthsshouldslopeawayfromthefrontofthereplaceandchase
at1/8in.to1/4in.perfoot.Metalsafetystripsmustbeontopof
any combustible hearth materials used for moisture management.
Whenpurchasingareboxorreplacewerecommendyoualso
buy a weather cover to protect the unit from moisture. Never install
a burner where moisture cannot drain off easily. We recommend a
weather barrier to protect the burner from moisture.
Qualied Installing Agency
Installation and replacement of gas piping, gas utilization equipment
or accessories and repair and servicing of equipment shall be
performedonlybyaqualiedagency.Theterm"qualiedagency"
meansanyindividual,rm,corporationorcompanywhicheitherin
person or through a representative is engaged in and is responsible for
(a) the installation or replacement of gas piping or (b) the connection,
installation, repair or servicing of equipment, who is experienced in
such work, familiar with all precautions required and has complied
withalltherequirementsoftheauthorityhavingjurisdiction.
Local Codes
Whenthereplaceisconnectedtoaxedpipingsystem,the
installation must conform with local codes, or in the ab-
sence of local codes with the National Fuel Gas Code, ANSI
Z223.1/NFPA 54, or International Fuel Gas Code.
Wheninstalled,thereplacemustbeelectricallygrounded
in accordance with local codes, or in the absence of local
codes with the National Electrical Code, ANSI/NFPA 70, if
applicable.
Commonwealth of Massachusetts: The installation must be
madebyalicensedplumberorgastterintheCommonwealth
of Massachusetts.
The installation must conform with local codes or, in the absence
oflocalcodes,withtheNationalFuelGasCode,ANSIZ223.1.*
*Available from the American National Standards Institute, Inc. 1430
Broadway, New York, N.Y. 10018.
High Altitudes
For altitudes/elevations above 2,000 feet (610m), ratings should be
reduced at the rate of 4 percent for each 1,000 feet (305m) above
sea level. Contact the manufacturer or your gas company before
changingspud/oricesize.
Well Head Gas Installations
Some natural gas utilities use "well head" gas. This may affect the
Btu output of the unit. Contact the gas company for the heating value.
Contact the manufacturer or your gas company before changing
spud/oricesize.
Instructions to Installer
1. Installer must leave instruction manual with owner after
installation.
2. Installer must have owner fill out and mail registration
card supplied with this fireplace or register online at
www.empirecomfort.com.
3. Installer should show owner how to start and operate outdoor
replace.
AlwaysconsultyourlocalBuildingDepartmentregardingregulations,
codes or ordinances which apply to the installation of an outdoor
gasreplace.
WARNING
To avoid injury or damage to the replace or surrounding
area, do not burn wood or other solid fuels in this replace.
WARNING
ANY CHANGE TO THIS FIREPLACE OR ITS CONTROLS CAN
BE DANGEROUS.
Improper installation or use of the replace can cause seri-
ous injury or death from re, burns, explosion or carbon
monoxide poisoning.
Thisseriesisdesigncertiedinaccordancewith
ANSI Z21.97/CSA
2.41 for Outdoor Gas Fireplaces
and should be installed according
to these instructions.
Any alteration of the original design, installing it other than as
shown in these instructions or using a type of gas not shown
on the rating plate, is the responsibility of the person and
company making the change.
Manual Valve Safety System
When the burner ignites, a thermocouple senses a signal (electrical
current)thatenergizesamagnetinthegasvalve.After30to60
seconds, the control knob can be released. If the thermocouple
doesnotsensetheame,thegaswillshutoff.
Important
AllcorrespondenceshouldrefertocompleteModelNumber,Serial
Number and type of gas.
Moisture Resistance
Thisoutdoorreplacewillshedmoderateamountsofwater,butis
not waterproof. Water and condensing water vapor may enter the
chase under certain conditions.
Thereplacewillnotperformasanexteriorwall.Moisturepenetration
must beconsideredforconstruction that places the replace in
structure walls or on moisture sensitive surfaces.
When installed on exterior walls: Empire Comfort Systems
recommends the replace chase be constructed outside the
structure's weather envelope. Where the platform meets the wall,
usea ashingdetailsimilar tothat requiredforattached decks.
Chase platforms, including hearths should slope away from the
structureat1/4in.perfoot.Thereplacecanbeshimmedlevel.
When installed on surfaces where water may collect or cause
damage:EmpireComfortSystemsrecommendsaslopeof1/8to
1/4in.perfoottowardsthedrainportsuggested.Thereplacecan
be shimmed level.
41309-2-0620 Page 9
CLEARANCES
D
C
E
B
A
F
Index
Letter
Description
Dimension from
Fireplace Opening
(in inches)
A
From ground or other
combustible surface
10-1/4*
B From Side Walls 6
C From Ceiling (minimum) 24
D AlcoveWidth(minimum) 72
E AlcoveDepth(maximum) 24
F Ceiling Height (minimum) 90
*Note: DimensionAincludes3-1/2in.underreplaceforsupport
framing and drain tray installation.
Figure 3 - Alcove Clearances
Minimum Wall and Ceiling Clearances
SidewallClearances:Theclearancefromtheinsideofthereplace
to any combustible wall should not be less than 6 in.
Ceiling Clearances: The ceiling height should not be less than
24 in. from the top opening.
Mantel Clearances: If a combustible mantel is installed, it must meet
the clearance requirements detailed in Figure 2.
COMBUSTIBLES
ALLOWED
MANTEL
2”
4”
6”
8”
12”
12”
16 13/16”
14 3/8”
19 3/16”
21 5/8”
24”
10”
Figure 2 - Mantel Clearances
Donotattachcombustiblematerialtothemantelofyourreplace.
Thisisarehazard.
Figure 1
COMBUSTIBLE MATERIALS
No greeting cards, stockings or ornamentation of any type should be
placedonorattachedtothereplace.Thisisaheatingappliance.
Theowofheatcanignitecombustibles.
NOTE: Forsee-thrureplaces,thisappliestobothsidesofthe
unit.
Television Considerations
Installingatelevisionaboveareplacehasbecomeincreasingly
popular;however,theareaaboveanyreplacegetshotandmost
TV manufacturers recommend against placing their products near
a heat source.
Ifyouinstallatelevisionabovethisreplace,EmpireComfortSys-
temsacceptsnoresponsibilityfordamageorinjuries.Followthe
television manufacturer’s installation instructions, including any
recommendations regarding proximity to heat sources.
IfyouhaveaTVaboveyourreplace,turnoffthereplaceand
let it cool completely before servicing or touching any buttons on
the TV.
41309-2-0620Page 10
Figure 4
Front and Side View of Non-Combustible Panel to Opening on Fireplace's Face
*NOTE: 8-in.minimumofnon-combustiblematerialisrequiredabovethereplaceopening.16-in.ofnon-combustiblematerialis
providedtoallowforplacementofwalljointinacoolertemperaturezone.
*
NON-COMBUSTIBLE
WALL BOARD PROVIDED
Framing
Header
Fireplace
Opening
2 1/4”
Fireplace
Opening
Support
Framing
Non-Combustible
Panels installed
over Appliance Opening
Non-Combustible
Side Panel
BOTH SIDES
6 1/2
8” *
Fireplace Nailing
Header
CLEARANCES
41309-2-0620 Page 11
FIREPLACE DIMENSIONS
INDEX
LETTER
DIMENSION DESCRIPTION
OLL60FP OLL60SP
Dimensions in Inches
A Themaximumheightofreboxface 30-7/8 30-7/8
B Themaximumwidthofthereboxface(excludingnailinganges)
63-3/4 63-3/4
C Themaximumdepthoftherebox 19-1/8 22-1/2
D Theheightofthereboxopening 16-3/16 16-3/16
E Thewidthofthereboxopening 60 60
F Theinteriordepthoftherebox(notshown)
19 23-7/8
G Therearexteriorwidthoftherebox(notshown) 60 60
K Height from the bottom of the box to the gas line opening 2-9/16 2-9/16
L Depth from the front of the box to gas line opening 5-3/16 5-3/16
M Depth from rear of box to gas line opening 5-3/16 N/A
N Glass height 3-1/2 3-1/2
O Glass width 59-3/8 59-3/8
Q Distancefromoortoreplaceopening 6-11/16 6-11/16
N/A-Notapplicableforthisunit.
K
Q
D
K
B
C
L
L
N
E
O
A
K
Q
D
C
L
A
B
N
E
O
T
T
T
M
41309-2-0620Page 12
What to Consider Before Installing
1. Verifyreplacegastypeandgassupplytypearethesame.
2. Look for a location where combustibles will not interfere.
3. 120V GFI power outlet will be needed for LED lights
4. Choose a location for gas shutoff valve.
5. Verify ventilation meets at least minimum requirements
6. Wind and rain direction
7. Drainageunderreplace.
8. Drainpanandweatherdooraccessories.
9. Glass accessories
Whenplanningtheinstallationforthereplace,determinewherethe
unit is to be installed and whether optional accessories are desired.
Gas supply piping should also be planned at this time.
Thereplacecanbemountedonanyofthesesurfaces:
1. Araisedframeofcombustiblematerialsocontactismadeon
allfourperimeteredgesofthebottomofthereplaceatleast
3-1/2in.abovetheoor.
2. Fourcornersof the replaceso contact ismadeon all four
perimeter edges on the bottom of the unit at least 3-1/2 in.
abovetheoor.Checklocalcodesforallowances.
Atthispoint,youshouldhavedecidedwhatcomponentstoinclude
inyourinstallation,andwherethereplaceistobelocated.Ifthis
has not been done, stop and consult your dealer for assistance
with this planning.
WARNING
This replace is intended for installation on an outdoor patio
or yard. This replace shall be used only outdoors in a well
ventilated space and shall NOT be used in a building, garage,
or other enclosed area. This replace cannot be installed
with an opening to the inside of a residence.
NOTICE: This fireplace is NOT equipped with an Oxygen
Depletion Sensor (ODS) pilot.
Installationofthe replace may beinan"open" area, however
it is recommended that this fireplace be installed in an area
shelteredfromdirectwinds.Directwindwillcauseanerraticame
andpossibleburneroutage.Thiserraticamecouldalsoleadto
excessive black soot. These are nuisance issues rather than safety
issues.Avoidareaswhereexcessivemoistureorrunningwatermay
benearoronreplace.
Typical installation may include covered patio, open porch, gazebo
or an outside wall of a house.
Minimum porch area – 96 square feet
Minimum ceiling height – 90 inches
LED Lights will require a 120V GFI power outlet on the valve side of
thereplace.TheGFIplugwillbelocatedoutsideofthereplace.
Ajunctionboxisprovidedinsidethereplacetoprovidealocation
to plug in the LEDs.
Outdoor Fireplace Enclosure Requirements
Donotinstallreplaceuntilallnecessaryprovisionsaremadefor
combustion and ventilation air. Consult the written instructions
providedwiththereplaceforinformationconcerningcombustion
and ventilation air. In the absence of instructions, refer to the
NationalFuelGasCode,ANSIZ223.1/NFPA54,AirforCombustion
and Ventilation, or applicable local codes.
Installation in partial enclosures must conform with one of the
following conditions:
With walls on all sides, but with no overhead cover.
See Figure 5.
FIREPLACE
Figure 5
Within a partial enclosure which includes an overhead cover
and no more than two side walls. These side walls may be
parallel, as in a breezeway or at right angles to each side.
See Figure 6.
FIREPLACE
Figure 6
PLANNING INSTALLATION
41309-2-0620 Page 13
PLANNING INSTALLATION (CONT'D)
Within a partial enclosure that includes an overhead cover and
three side walls, as long as 30 percent or more of the horizontal
periphery (perimeter of walls and open side) of the enclosure
is permanently open. See Figure 7.
FIREPLACE
Figure 7
Ifinstallinginascreenedinporch,theopenspacemustbeadjusted
(increased)from30percent(adjustedopenspace=30%/%open
area of the screen mesh). "Example, if you used a screen with a
66%openarea,theminimumopenspaceofyourbuildingmust
be46%oftheperiphery.Ifyouhaveacoveredscreened-inporch
that has two side walls that are 16', one wall that was against the
house that's 20' and one open side that's 20', you would have a
perimeterof72'.Youwouldneedtohave33'oftheperimeteropen
(72'x46%=33')."
(Contact your screen manufacturer or screen dealer to
determine your screens open area).
ATTENTION: Vinyl Soffit, Vinyl Ceiling, Vinyl Overhang
Disclaimer
Clearances are to heat resistant material (i.e. wood, metal). This
does not include vinyl. Empire Comfort Systems Inc. will not be
held responsible for heat damage caused from terminating under
vinyl overhangs, vinyl ceilings or vinyl ventilated/unventilated
softs.
WARNING
Improper installation, adjustment, alteration, service or
maintenance can cause property damage, personal injury
or loss of life. Installation and service must be performed
by a qualied installer, service agency or the gas supplier.
Gas Line Connection
Thereplace isdesignedtoaccepta1/2in. gasline.Havethe
lineinstalledbyaqualiedservicepersoninaccordancewithall
building codes. Consult local building codes to properly size the gas
supply line leading to the 1/2 in. hook-up at the unit. The state of
Massachusettsrequiresthataexiblereplaceconnectorcannot
exceed three feet in length.
Aex-lineconnectiontothevalvesisprovided.The gas shut-off
valve must be located outside of the unit in an accessible area.
Check gas type on the rating label located on the back of the control
door. If the gas listed on the rating label located on the control panel,
doesnotmatchyourgassupply,DONOTINSTALL.Contactyour
dealer for proper model or conversion kit.
AlwaysuseanexternalregulatorforallPropanereplacestoreduce
the supply tank pressure to a maximum of 13 in. w.c.
WARNING
Connection directly to an unregulated Propane Tank can
cause an explosion.
WARNING
Risk of re, explosion or asphyxiation. Ensure no ignition,
ame or spark are near during installation. This includes
cigarettes or cell phones.
Leak test all connections with a soap and water solution. Bubble
formation will indicate a leak. Use caution to avoid burns.
Figure 8
Water Drainage Requirement*
Provisionsmustbemadetodrainwaterawayfromtheunit.An
optional drain pan can be purchased from your Empire Dealer to
tunderthereplace.Ifinstallingtheoptionaldrainpan,itmust
beinstalledpriortoinstallingthereplace.Formoreinformation,
refer to the installation instructions supplied with the drain pan. If
this drain is not used, other water drainage is required.
*If installing a drain tray accessory, add at least 6 inches more to
the height of the enclosure to allow enough space for the drain
pan, connector, and tubing clearance.
41309-2-0620Page 14
Electrical Considerations
CAUTION
All wiring should be done by a qualied electrician and
shall be in compliance with all local, city and state building
codes. Before making the electrical connection, make sure
that the main power supply is disconnected. The replace,
when installed, must be electrically grounded in accordance
with local codes, or in the absence of local codes, with the
National Electrical Code ANSI/NFPA 70 (Latest Edition).
Afactoryinstalledjunctionboxislocatedonthelowerrightside
ofthereplace.Thejunctionboxandwiringmayberelocatedto
theoppositesideofthereplaceifdesired.Wiringtothejunction
box must be metal clad or enclosed in a conduit and must be
approved for outdoor use. Connect the wiring to an external GFI
protectedoutletinstallednearthereplace.SeeFigure9.
GFI Outlet
CONTROLS
Figure 9
PLANNING INSTALLATION (CONT'D)
41309-2-0620 Page 15
FIREPLACE FRAMING AND INSTALLATION
Unpacking the Fireplace
Afterremovaloftheplasticwrap,removethescrewsholdingthe
cornerpostsandplywoodtothereplace.Discardthecorner
posts and plywood.
Thenon-combustibleboardisunderthereplaceonthepallet.
Removeanyprotectivelmfromreplaceandallcomponents
(nailinganges,nailingheaders,etc.).
Framing
Fireplacesupportframingshouldbebuiltbeforethereplaceisset
inplace.Thereplaceframingmaybeconstructedof2x4lumber.
Theframingheadersmustrestonthereplacenailingheaders.
Refer to Figure 11 for minimum framing dimensions.
CAUTION
Measure replace dimensions and verify framing methods,
and wall covering details before framing construction begins.
Framing dimension A includes a 16-1/2 in. clearance for nailing
headers on rebox. After installing rebox into framing, the
nished wall surface must cover the 16-1/2 in. opening above
the rebox.
B
KEEP OPEN
AREA FOR
DRAINAGE
C
A
WATER
DRAINAGE
THIS SIDE
FRAMING DIMENSIONS (in inches)
OLL60FP OLL60SP
Height A 31 31
Width B 64 64
Depth C 19-1/4 22-1/2
Figure 11 - Fireplace Framing
Beforecompletingtheframingandinstallingreplace,providea
pathforwaterdrainageoutofthereplace.
Determine if the optional accessory drain pan will be used. See
Page 12. If the drain pan will be installed, follow the instructions
provided with the drain pan kit to install it at this point.
Installation
1. Choose installation location.
2. Constructthesupportframingforthereplace.Seeframing
dimensions, Figure 11.SeeClearances,Pages8and9.
3. Locatethenailingangesintheinstallationenvelopeand
attachthemtothesidesofthereplacewithtwo#10-32x1/2
hex screws each.
Figure 12 - Nailing Flange Position
4. Bendthenailingangetabsoutatrightanglesuntiltheyare
ushwiththefaceofthereplace.
For see-through replaces only: Bend the tabs on one
sideofthereplaceonly.Bendthetabsonthetopheaderof
the opposite face at right angles to allow the tabs to clear the
enclosureframingwhenslidingthereplaceintoposisiton.
See Figure 13.
5. Liftthereplaceandsetintotheframe.Slidethereplace
backuntilnailingangesmeettheframe.Securethere-
placetotheframewithone#8x1drywallscreweach.For
see-thrureplaces,bendthebacksidenailingangesout
andrightanglesandsecurewithone#8x1drywallscrew
each.
Figure 13
FRAMING & INSTALLATION
41309-2-0620Page 16
FIREPLACE FRAMING AND INSTALLATION
6. Secure the nailing header to the side framing studs with four
#8x1drywallscrews
7. Toconnectthegaslineandinstalltheelectricalconnection,
theburnerassemblymustbetiltedupwardinthereplace.
a Remove the control door by opening the door, removing
the center piovt pin, and lifting the door upward to dis-
engage the slots on the ends of the door from the pivot
pins.
b. Remove the two control door pivot bolts and washers.
See Figure 14.
Figure 14
c. Remove two screws from front corners of the control
panel with a Phillips head screw driver. See Figure 15.
Figure 15
d. Lift front of burner assembly and tilt upwards and toward
thebackofthereplace.Retrievethetwosupportsfrom
insidethereplaceandplaceoneeachsideagainstthe
front corners of the cabinet bottom and under the front
corners of the control panel.
NOTE: Use care when raising the burner to avoid
scratchingthestainlessinteriorofthereplace.
PROP SUPPORT
IN FOUR CORNERS
Figure 16
8. Installgasandelectricalsuppliestoreplace.Seepage17
for gas supply requirements. For ease of installation, the
gas and electrical supply are located on the valve side of the
replace.Bothmayberelocatedtoentertheoppositesideof
thereplace.
FRAMING & INSTALLATION
41309-2-0620 Page17
FIREPLACE FRAMING AND INSTALLATION
GFI Outlet
CONTROLS
Figure 17
GROUND
CONDUIT
RECEPTACLE
120 VOLT
POWER SUPPLY
OUTLET
COVER
GASKET
Figure 18
ELECTRICAL SUPPLY
CAUTION
All wiring should be done by a qualied electrician and
shall be in compliance with all local, city and state building
codes. Before making the electrical connection, make sure
that the main power supply is disconnected. The replace,
when installed, must be electrically grounded in accordance
with local codes, or in the absence of local codes, with the
National Electrical Code ANSI/NFPA 70 (Latest Edition).
Wiringtothejunctionboxmustbemetalcladorenclosedina
conduitandmustbeapprovedforoutdooruse.Aconnectorfor
thejunctionboxtoaccommodate1/2-in.conduitissuppliedinthe
instructionenvelope.Thereplacereceptaclemustbeconnected
toanexternalGFIprotectedoutletinstallednearthereplace
See Figure 17.
Route the wiring from the external GFI outlet through the conduit
tothejunctionbox.Leaveapproximately6-in.ofwireinthejunc-
tion box for connection.
Retrieve the receptacle and cover from the instruction enve-
lope.Attachtheblackwiretothegoldscrewandwhitewireto
the silver screw of the receptacle. The ground wire should be
attachedtothegreengroundscrewonthejunctionboxandthe
receptacle.
Place receptacle in position and attach cover plate. Make sure
the cover plate doors open upward. Be sure to test the receptacle
to ensure the GFI circuit functions properly. Plug transformer
power cord into receptacle, and close the unused receptacle
door.
41309-2-0620Page18
FIREPLACE FRAMING AND INSTALLATION
Solidfuelsshallnotbeburnedinthisreplace.
The maximum gas inlet supply pressure is 11 in. for Propane
and 10.5 in. for Natural.
Forreplacesforxedfuelpipingsystemandequippedwith
areplacegaspressureregulator,therequiredmanifold
pressure in inches water column: 11 in. for Propane and
4.5 in. Natural.
Forreplacesforxedfuelpipingsystemandequippedwith
areplacegaspressureregulator,thereplaceanditsindi-
vidual shutoff valve must be disconnected from the gas sup-
ply piping system during any pressure testing of that system
at test pressures in excess of 1/2 psi (3.5 kPa).
Thereplacemustbeisolatedfromthegassupplypiping
system by closing its individual manual shutoff valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psi (3.5 kPa).
Check all local codes for requirements, especially for the size and
type of gas supply line required.
RECOMMENDED MINIMUM GAS PIPE DIAMETER
Pipe
Length
Schedule 40 Pipe
Inside Diameter
Tubing, Type L
Outside Diameter
Natural Propane Natural Propane
0-10 feet
0-3 meters
1/2 in.
12.7mm
3/8in.
9.5mm
1/2 in.
12.7mm
3/8in.
9.5mm
10-40 feet
4-12 meters
1/2 in.
12.7mm
1/2 in.
12.7mm
5/8in.
15.9mm
1/2 in.
12.7mm
40-100 feet
13-30 meters
1/2 in.
12.7mm
1/2 in.
12.7mm
3/4 in.
19mm
1/2 in.
12.7mm
100-150 feet
31-46 meters
3/4 in.
19mm
1/2 in.
12.7mm
7/8in.
22.2mm
3/4 in.
19mm
NOTE:Checktoconrmwhetheryourlocalcodesallowplasticor
copper tubing for outdoor use.
NOTE: Because some municipalities have additional local codes,
consult your local authority and installation code.
Installing a Manual Gas Shut-Off Valve
Eachreplacemusthaveanaccessiblemanualgasshut-offvalve
located in the vicinity of the unit. Where none exists, or where its size
or location is not adequate, contact your local authorized installer
for installation or relocation.
Compoundsusedonthreadedjointsofgaspipingshallberesistant
totheactionofliqueedpetroleumgases.Thegaslinesmustbe
checked for leaks by the installer. This should be done with a soap
solution watching for bubbles on all exposed connections, and if
unexposed, a pressure test should be made. To avoid damage to
the gas piping, removal all testing solution when testing is complete.
WARNING
Never use an exposed ame to check for leaks. Fireplace
must be disconnected from piping at inlet of control valve and
pipe capped or plugged for pressure test. Never pressure test
with replace connected; control valve will sustain damage!
Agasvalveandgroundjointunionshouldbeinstalledinthegas
line upstream of the gas control to aid in servicing. It is required by
the National Fuel Gas Code that a drip line be installed near the
gas inlet. This should consist of a vertical length of pipe connected
intothegaslinebyateetingwithacaponthebottominwhich
condensation and foreign particles may collect.
The use of the following gas connectors is recommended:
— ANSIZ21.24ApplianceConnectorsofCorrugatedMetalTubing
and Fittings
— ANSI Z21.45 Assembled Flexible Appliance Connectors of
OtherThanAll-MetalConstruction
The above connectors may be used if acceptable by the authority
havingjurisdictionTheCommonwealthofMassachusettsrequires
thataexibleapplianceconnectorcannotexceedthreefeetinlength.
NATURAL
GAS SUPPLY
SHUT
-OFF
VA
LVE
FLEX TUBING
MALE NPT to
MALE FLARE
REGULATOR
NIPPLE
NATURAL
GAS SUPPLY
MALE NPT to
MALE FLARE
LP GAS
SUPPLY
SHUT-OFF
VALVE
FLEX TUBING
MALE NPT to
MALE FLARE
VALVE
MALE NPT to
MALE FLARE
LP GAS
SUPPLY
VALVE
FEMALE NPT to
FEMALE NPT
FEMALE NPT to
FEMALE NPT
Figure 19
NOTE: Gas shut-off valve shown. Other valves approved to use
with gas allowed.
Flex tubing to valve is pre-installed at the factory. Flare connector
is located in the envelope.
Anaccessiblemanualgasshutoffvalvemustbeinstalled
externaltothereplace.
GAS SUPPLY
41309-2-0620 Page 19
WARNING
If these instructions are not followed exactly, a re caus-
ing death or serious injury may occur.
Propane Cylinder Specications
Thisreplacecanbeusedwithanon-disposableself-contained
Propane Gas supply system:
Propane cylinders may be acceptable for use with the
replaceprovidedtheyarecompatiblewiththereplace
retention means.
Propane Gas supply cylinder must be constructed and
marked in accordance with the U.S. Department of
Transportation (D.O.T.) Specications for Propane Gas
Cylinders, or the Standard for Cylinders, Spheres and
Tubes for Transportation of Dangerous Goods and Com-
mission, CAN/CSA-B339 as applicable.
Propane Gas supply cylinders between 4 and 40
poundsmusthaveanoverllpreventiondevice.
Propane Gas supply cylinder must have a connection
devicecompatiblewiththeconnectionofthereplace.
IfthereplaceisequippedwithaCGANo.600Cylinder
Connection Device, the cylinder must be disconnected
whenthereplaceisnotinuse.
Ifreplaceistobepermanentlyconnectedtoagaspip-
ing system from a remote supply tank, installation must
be in accordance with local codes or, in the absence
of local codes, with the National Fuel Gas Codes ANSI
Z223.1/NFPA 54.
Adentedorrustycylindermaybehazardousandshould
be checked by your propane supplier. Never use a cylin-
der with a damaged valve.
Thisreplacemaybeusedwitha20lb.(9.1kg)or30lb
(13.6 kg) size propane cylinder only (not supplied).
The propane cylinder must be provided with a shut-
off valve terminating in a propane cylinder valve type
QCC1, and a safety relief device having direct commu-
nication with the vapor space of the cylinder.
The cylinder supply system must be arranged for vapor
withdrawal and the cylinder shall include a collar to
protect the cylinder valve.
The Propane Gas cylinder must be provided with a
listedoverllprotectiondevice(OPD).Neverllthe
cylinderbeyond80percentfull.
Do not store a spare Propane Gas cylinder under or
nearthisreplace.
Use only a pressure regulator and hose assembly that
suppliesapressureof11in.watercolumntothere-
placeandhasaQCC1typetting.
Cylinders to be used with this unit must be supplied with
aQCC1cylindervalve.AQCC1cylinderhasapositive
seatingconnection,whichwillnotallowgasowuntila
positive seal has been achieved. It is also equipped with
anexcessowdevice.Inordertoattainfullowtothe
replace,thevalvemustbeintheoffpositionwhenthe
cylinder valve is turned on.
WARNING
A re will result if the gas supply hose makes contact with
the underside of the replace.
Propane Gas
Attachcylinderretainingbracketsuppliedtothebaseofthecyl-
inder. Then secure to the surface to which it sits. Cylinder should
be on a level surface.
Cylinder Retaining Bracket
1. Fasten the bracket to the bottom of the propane bottle using
bolt and nut (not supplied).
2. Tighten the lag screw into the mounting surface leaving ap-
proximately 1/4 in. of thread above the surface.
3. Slide propane bottle into position so that the bracket slides
under the head of the lag screw.
4. Tighten the lag screw onto the bracket.
5. For fastening to a concrete surface a concrete anchor will be
required. (Not supplied)
Cylinder Connection: Ensure the gas regulator hose is kink
free. Remove the cap or plug from the cylinder fuel valve. Insert
the black QCC1 regulator nipple onto the QCC1 fuel valve. Hand
tightenclockwise.Donotusetools.Leaktestalljointspriorto
usingthereplace.Aleaktestmustbeperformedannuallyand
each time a cylinder is hooked up or if a part of the gas system
isreplaced.Ifthisreplaceistobeconnecteddirectlytoahouse
propane gas supply line, follow the instructions for the natural
gas hook-up.
Safety Considerations
Make sure cylinder valve is in its full off position. (Turn clock-
wise to stop).
Check cylinder valve features to ensure it has proper ex-
ternal mating threads. (Cylinder Valve Marked: USE WITH
TYPE 1)
Inspect hose for damage. Never attempt to use damaged or
plugged equipment. See your local Propane Gas Dealer for
repairs.
When connecting regulator assembly to the cylinder valve,
hand tighten black QCC1 nut clockwise to a positive stop.
DO NOT use a wrench to tighten. Use of a wrench may dam-
age the quick closing coupling nut and result in a hazardous
condition.
Locate the hose out of pathways where people may trip over
itorinareaswherethehosemaybesubjecttoaccidental
damage.
Open cylinder valve fully (counter-clockwise). Turn the shut
off valve at the unit slowly to the on position and use a soapy
water solution to check all connections for leaks as indicated
inthediagramsbeforeattemptingtolightthereplace.Ifa
leakisfound,turntankvalveoffanddonotusethereplace
until repairs can be made.
FIREPLACE FRAMING AND INSTALLATION
PROPANE GAS CYLINDER INFORMATION
41309-2-0620Page 20
Enclosures For Propane Gas Supply Systems
Enclosures for Propane Gas supply cylinders shall be ventilated
byopeningsatthelevelofthecylindervalveandatoorlevel.
The effectiveness of the opening(s) for purposes of ventilation
shall be determined with the Propane Gas supply cylinder(s) in
place. This shall be accomplished by one of the following.
a. One side of the enclosure shall be completely open; or
b. For an enclosure having four sides, a top and a bottom:
1. Atleasttwoventilationopeningsatcylindervalvelevel
shall be provided in the side wall, equally sized, spaced
at180degrees(3.14rad),andunobstructed.Each
opening shall have a total free area of not less than
1/2 sq in per pound (2.3 sq. cm/kg) of stored fuel capac-
ity and not less than a total free area of 10 sq in (64.5
sq. cm).
2. Ventilationopening(s)shallbeprovidedatoorlevel
and shall have a total free area of not less than 1/2 sq in
per pound (3.2 sq. cm/kg) of stored fuel capacity and not
less than a total free area of 10 sq in (64.5 sq. cm). If
ventilationopeningsatoorlevelareinasideall,there
shall be at least two openings. The bottom of the open-
ingsshallbeatoorlevelandtheupperedgenomore
than5in.(127mm)abovetheoor.Theopeningsshall
beequallysized,spacedat180degrees(3.14rad)and
unobstructed.
3. Every opening shall have minimum dimensions so as to
permittheentranceofa1/8in.(3.2mm)diameterrod.
4. There shall be a minimum clearance of 2 in. (51 mm)
betweenthelowersurfaceoftheoorofthePropane
Gas supply cylinder enclosure and the ground.
Cylinder valves shall be readily accessible for hand opera-
tion.Adoorontheenclosuretogainaccesstothecylinder
valves is acceptable, provided it is non-locking and can be
opened without the use of tools.
Thedesignofthereplaceshallbesuchthat(1)the
Propane Gas supply cylinder(s) can be connected, discon-
nected and the connections inspected and tested outside the
cylinder enclosure; and (2) those connections which could
be disturbed when installing the cylinder(s) in the enclosure
can be leak tested inside the enclosure;
Ventilation openings in sidewalls shall not communicate
directlywithotherenclosuresofthereplace.
The enclosure for the Propane Gas cylinder shall isolate the
cylinder from the burner compartment to provide:
a. Shielding from heat radiation;
b. Aamebarrier;and
c. Protection from foreign material.
Be certain to mount the Propane Gas cylinder on a at
surface and restrain it using a cylinder retaining bracket to
prevent it from tipping.
NON-LOCKING
DOOR
TOP AND SIDE PARTITION
TO ISOLATE TANK FROM
FIREPLACE
OPENING B
OPENING A
C
1” MAX
5” MAX
TOP AND SIDE PARTITION
TO ISOLATE TANK FROM
FIREPLACE
FIREPLACE POSITIONED
ABOVE TANK ENCLOSURE
FIREPLACE POSITIONED
BESIDE TANK ENCLOSURE
5” MAX
1” MAX
2” MIN
Cylinder
Size
Opening
Area A
Opening
Area B
Recommended
Dimension C
20lb
(9.1kg)
20 sq.in.
(130cm
2
)
10 sq.in.
(65cm
2
)
34 in.
(863mm)
30lb
(13.6kg)
30 sq.in.
(195cm
2
)
15 sq.in.
(100cm
2
)
34 in.
(863mm)
NOTE: There shall be a minimum clearance of 2 in. (51 mm)
betweenthelowersurfaceoftheoorofthePropaneGassupply
cylinder enclosure and the ground.
Figure 20
FIREPLACE FRAMING AND INSTALLATION
PROPANE GAS CYLINDER INFORMATION
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72

White Mountain Hearth Outdoor Linear Fireplace 60 (OLL60FP/SP) Le manuel du propriétaire

Catégorie
Cheminées
Taper
Le manuel du propriétaire
Ce manuel convient également à