Ryobi RYi2200A Mode d'emploi

Catégorie
Groupes électrogènes
Taper
Mode d'emploi

Ce manuel convient également à

OPERATOR’S MANUAL
MANUEL D’UTILISATION
MANUAL DEL OPERADOR
DIGITAL INVERTER GENERATOR
GÉNÉRATEUR NUMÉRIQUE D’INVERSEUR
GENERADOR DEL INVERSOR DE DIGITACES
RYi2200
To register your Ryobi product, please visit:
http://register.ryobitools.com/
Pour enregistrer votre produit de Ryobi, s’il vous plaît la visite:
http://register.ryobitools.com/
Para registrar su producto de Ryobi, por favor visita:
http://register.ryobitools.com/
NEUTRAL FLOATING
FLOTTANTE NEUTRE / NEUTRAL DE FLOTACIÓN
NOTICE AVIS AVISO
Do not use E15 or E85 fuel (or fuel
containing greater than 10% ethanol)
in this product. It is a violation of fed-
eral law and will damage the unit and void your warranty.
Ne pas utiliser d’essence E15 ou E85 (ou un carburant
contenant plus de 10 % d’éthanol) dans ce produit. Une
telle utilisation représente une violation de la loi fédérale et
endommagera l’appareil et annulera la garantie.
No utilice combustibles E15 o E85 (ni combustibles que
contengan más de 10 % de etanol) con este producto. Esto
constituye una violación a la ley federal, dañará la unidad
y anulará la garantía.
Ce générateur a été conçu et fabriqué conformément à nos
strictes normes de fiabilité, de simplicité d’emploi et de sécurité
d’utilisation. Correctement entretenu, il vous donnera des années
de fonctionnement robuste et sans problème.
AVERTISSEMENT : Pour réduire les risques de
blessures, l’utilisateur doit lire et veiller à bien comprendre
le manuel d’utilisation avant d’utiliser ce produit. Si tous
les avertissements et toutes les consignes de sécurités et
instructions du manuel d’utilisation ne sont pas bien compris,
ne pas utiliser ce produit.
Su generador ha sido diseñado y fabricado de conformidad
con estrictas normas para brindar fiabilidad, facilidad de uso y
seguridad para el operador. Con el debido cuidado, le brindará
muchos años de sólido y eficiente funcionamiento
ADVERTENCIA: Para reducir el riesgo de lesiones,
el usuario debe leer y comprender el manual del operador
antes de usar este producto. Si no comprende los avisos de
advertencia y las instrucciones del manual del operador, no
utilice este producto.
CONSERVER CE MANUEL
POUR FUTURE RÉFÉRENCE
GUARDE ESTE MANUAL
PARA FUTURAS CONSULTAS
SAVE THIS MANUAL FOR FUTURE REFERENCE
Your generator has been engineered and manufactured to our high standard for dependability, ease of operation, and operator
safety. When properly cared for, it will give you years of rugged, trouble-free performance.
WARNING: To reduce the risk of injury, the user must read and understand the operators manual before using this
product. If you do not understand the warnings and instructions in the operator’s manual, do not use this product.
v
2 — English
TABLE OF CONTENTS
INTRODUCTION
Introduction ......................................................................................................................................................................2
Important Safety Instructions ........................................................................................................................................3-4
Specific Safety Rules ........................................................................................................................................................4
 Symbols ......................................................................................................................................................................... 5-7
Electrical ........................................................................................................................................................................7-9
Features ...................................................................................................................................................................... 9-10
Assembly ........................................................................................................................................................................ 11
Operation ................................................................................................................................................................... 12-14
Maintenance ..............................................................................................................................................................15-16
Troubleshooting ..............................................................................................................................................................17
Warranty ....................................................................................................................................................................18-20
Parts Ordering / Service ....................................................................................................................................Back Page
DANGER:
GROUNDING THE GENERATOR
To reduce the risk of shock or electrocution, generator must be
properly grounded. The nut and ground terminal on the frame must
always be used to connect the generator to a suitable ground
source. The ground path should be made with #8 size wire. Con-
nect the terminal of the ground wire between the lock washer and
the nut, and tighten the nut fully. Connect the other end of the
wire securely to a suitable ground source.
The National Electric Code contains several practical ways in
which to establish a good ground source. If a steel or iron rod is
used, it should be at least 5/8 in. diameter, and if a nonferrous
rod is used, it should be at least 1/2 in. diameter and be listed as
material for grounding. Drive the rod or pipe to a depth of 8 ft. If
a rock bottom is encountered less than 4 ft. down, bury the rod
or pipe in a trench.
All electrical tools and appliances operated from this generator
must be properly grounded by use of a third wire or be “Double
Insulated.”
It is recommended to:
1. Use electrical devices with 3-prong grounded plugs.
2. Use an extension cord intended for outdoor use with a 3-pole receptacle and a 3-prong plug at opposite ends to
ensure continuity of the ground protection from the generator to the appliance.
Check and adhere to all applicable federal, state, and local regulations relating to grounding specifications. Consult a
qualified electrician or service personnel if the grounding instructions are not completely understood or if in doubt as
to whether the generator is properly grounded.
This product has many features for making its use more pleasant and enjoyable. Safety, performance, and dependability
have been given top priority in the design of this product, making it easy to maintain and operate.
3 — English
IMPORTANT SAFETY INSTRUCTIONS
DANGER:
Carbon Monoxide. Using a generator indoors CAN KILL
YOU IN MINUTES.
Generator exhaust contains high levels of carbon mon-
oxide (CO), a poisonous gas you cannot see or smell. If
you can smell the generator exhaust, you are breathing
CO. But even if you cannot smell the exhaust, you could
be breathing CO.
Never use a generator inside homes, garages, crawl-
spaces, or other partly enclosed areas. Deadly levels
of carbon monoxide can build up in these areas. Us-
ing a fan or opening windows and doors does NOT
supply enough fresh air.
ONLY use a generator outdoors and far away from
open windows, doors, and vents. These openings
can pull in generator exhaust.
Even when you use a generator correctly, CO may
leak into the home. ALWAYS use a battery-powered or
battery-backup CO alarm in the home.
If you start to feel sick, dizzy, or weak after the generator
has been running, move to fresh air RIGHT AWAY. See
a doctor. You could have carbon monoxide poisoning.
WARNING:
Read and understand all instructions. Failure to follow
all instructions listed below could result in electrocution,
fire, and/or carbon monoxide poisoning, which can cause
death or serious injury.
WARNING:
National Electric Code requires generator to be grounded
to an approved earth ground. Before using the ground ter-
minal, consult a qualified electrician, electrical inspector,
or local agency having jurisdiction for local codes or or-
dinances that apply to the intended use of the generator.
SAVE THESE INSTRUCTIONS
This manual contains important instructions for this product
that should be followed during installation and maintenance
of the generator.
Do not connect to a building’s electrical system unless
the generator and transfer switch have been properly
installed and the electrical output has been verified by
a qualified electrician. The connection must isolate the
generator power from utility power and must comply with
all applicable laws and electrical codes.
Do not allow children or untrained individuals to use this
unit.
Do not start or operate the engine in a confined space,
building, near open windows, or in other unventilated
space where dangerous carbon monoxide fumes can
collect. Carbon monoxide, a colorless, odorless, and
extremely dangerous gas, can cause unconsciousness
or death.
Keep all bystanders, children, and pets at least 10 feet
away.
Wear sturdy and dry shoes or boots. Do not operate while
barefoot.
Do not operate generator when you are tired or under the
influence of drugs, alcohol, or medication.
Keep all parts of your body away from any moving parts
and all hot surfaces of the unit.
Do not touch bare wire or receptacles.
Do not use generator with electrical cords which are worn,
frayed, bare, or otherwise damaged.
Before storing, allow the engine to cool and drain fuel
from the unit.
Do not operate or store the generator in rain, snow, or
wet weather.
Store the generator in a well-ventilated area with the fuel
tank empty. Fuel should not be stored near the generator.
Empty fuel tank, turn the engine/choke lever to the off
position and restrain the unit from moving before trans-
porting in a vehicle.
Allow engine to cool for five minutes before refueling.
To reduce the risk of fire and burn injury, handle fuel with
care. It is highly flammable.
Do not smoke while handling fuel.
Store fuel in a container approved for gasoline.
Position the unit on level ground, stop engine, and allow
to cool before refueling.
Loosen fuel cap slowly to release pressure and to keep
fuel from escaping around the cap.
Tighten the fuel cap securely after refueling.
Wipe spilled fuel from the unit.
Never attempt to burn off spilled fuel under any circum-
stances.
Generators vibrate in normal use. During and after the
use of the generator, inspect the generator as well as
extension cords and power supply cords connected to
it for damage resulting from vibration. Have damaged
items repaired or replaced as necessary. Do not use plugs
or cords that show signs of damage such as broken or
cracked insulation or damaged blades.
For power outages, permanently installed stationary gen-
erators are better suited for providing back-up power to
the home. Even a properly connected portable generator
can become overloaded. This may result in overheating
or stressing the generator components, possibly leading
to generator failure.
4 — English
IMPORTANT SAFETY INSTRUCTIONS
SPECIFIC SAFETY RULES
WARNING:
When this generator is used to supply a building
wiring system: generator must be installed by a quali-
fied electrician and connected to a transfer switch as
a separately derived system in accordance with NFPA
70, National Electrical Code. The generator shall be
connected through a transfer switch that switches all
conductors other than the equipment grounding con-
ductor. The frame of the generator shall be connected to
an approved grounding electrode. Failure to isolate the
generator from power utility can result in death or injury
to electric utility workers.
Do not use this generator to provide power for emergency
medical equipment or life support devices.
Exhaust contains poisonous carbon monoxide, a color-
less, odorless gas. Breathing exhaust can cause loss
of consciousness and can lead to death. If running in a
confined or partially-enclosed area, the air may contain
a dangerous amount of carbon monoxide. To keep ex-
haust fumes from building up, always provide adequate
ventilation.
Always use a battery-powered carbon monoxide detec-
tor when running the generator. If you begin to feel sick,
dizzy, or weak while using the generator, shut it off and
get to fresh air immediately. See a doctor. You may have
carbon monoxide poisoning.
Place the generator on a flat, stable surface with a slope
of no more than 4°.
Operate outdoors in a well-ventilated, well-lit area isolated
from working areas to avoid noise interference.
Operating the generator in wet conditions could result in
electrocution. Keep the unit dry.
Keep the generator a minimum of 3 feet away from all
types of combustible material.
Do not operate generator near hazardous material.
Do not operate generator at a gas or natural gas filling
station.
Do not touch the muffler or cylinder during or immediately
after use; they are HOT and will cause burn injury.
This generator has a neutral floating condition. This means
the neutral conductor is not electrically connected to the
frame of the machine.
Do not allow the generator’s gas tank to overflow when
filling. Fill to 1 in. below the top neck of the gasoline tank
to allow for fuel expansion. Do not cover the fuel tank cap
when the engine is running. Covering the fuel tank cap
during use may cause engine failure and/or damage to
the tool.
Do not smoke when filling the generator with gasoline.
Shut down the engine and allow to cool completely before
adding gasoline or lubricant to the generator.
Do not remove the oil dipstick or the fuel tank cap when
the engine is running.
Pay close attention to all safety labels located on the
generator.
Keep children a minimum of 10 feet away from the gen-
erator at all times.
The unit operates best in temperatures between 23°F and
104°F with a relative humidity of 90% or less.
Operating voltage and frequency requirement of all
electronic equipment should be checked prior to plug-
ging them into this generator. Damage may result if the
equipment is not designed to operate within a +/- 10%
voltage variation, and +/- 3 hz frequency variation from
the generator name plate ratings.
For outdoor use only.
Save these instructions. Refer to them frequently and use
them to instruct others who may use this product. If you loan
someone this product, loan them these instructions also.
Use only authorized replacement parts and accessories
and follow instructions in the Maintenance section of this
manual. Use of unauthorized parts or failure to follow
maintenance instructions may create a risk of shock or
injury.
Maintain the unit per maintenance instructions in this
Operator’s Manual.
Inspect the unit before each use for loose fasteners, fuel
leaks, etc. Replace damaged parts.
5 — English
SYMBOLS
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper
interpretation of these symbols will allow you to operate the product better and safer.
SYMBOL NAME DESIGNATION/EXPLANATION
Safety Alert Indicates a potential personal injury hazard.
Read Operator’s Manual
To reduce the risk of injury, user must read and understand
operator’s manual before using this product.
Wet Conditions Alert Do not expose to rain or use in damp locations.
Electric Shock
Failure to use in dry conditions and to observe safe practices can
result in electric shock.
Toxic Fumes
Running generator gives off carbon monoxide, an odorless, color-
less, poison gas. Breathing carbon monoxide can cause nausea,
fainting, or death.
Fire/Explosion
Fuel and its vapors are extremely flammable and explosive. Fire
or explosion can cause severe burns or death.
Hot Surface
To reduce the risk of injury or damage, avoid contact with any hot
surface.
Lifting Hazard
To reduce the risk of serious injury, avoid attempting to lift the
generator alone.
Ground
Consult with local electrician to determine grounding requirements
before operation.
Electrocution
Failure to properly ground generator can result in electrocution,
especially if the generator is equipped with a wheel kit.
The following signal words and meanings are intended to explain the levels of risk associated with this product.
SYMBOL SIGNAL MEANING
DANGER:
Indicates an imminently hazardous situation, which, if not avoided, will result
in death or serious injury.
WARNING:
Indicates a potentially hazardous situation, which, if not avoided, could result
in death or serious injury.
CAUTION:
Indicates a potentially hazardous situation, which, if not avoided, may result in
minor or moderate injury.
NOTICE:
(Without Safety Alert Symbol) Indicates important information not related to an
injury hazard, such as a situation that may result in property damage.
6 — English
SYMBOLS
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper
interpretation of these symbols will allow you to operate the product better and safer.
SYMBOL NAME DESIGNATION/EXPLANATION
V Volts Voltage
A Amperes Current
Hz Hertz Frequency (cycles per second)
W Watt Power
hrs Hours Time
gal Gallon Volume
qt Quart Volume
SAFETY LABELS
The information below can be found on the generator. For your safety,
please study and understand all of the labels before starting the generator.
If any of the labels come off the unit or become hard to read, contact an
authorized service center for replacement.
You WILL be KILLED or SERIOUSLY HURT if you do not follow the
Operator’s Manual instructions.
Risk of Fire. Do not add fuel while the product is operating.
Generator is a potential source of electric shock. Do not expose to
moisture, rain, or snow. Do not operate with wet hands or feet.
Exhaust contains poisonous carbon monoxide gas that can cause
unconsciousness or DEATH. Operate in well-ventilated, outdoor areas away
from open windows or doors.
Failure to properly ground generator can result in electrocution, especially if the
generator is equipped with a wheel kit.
Do not expose to rain or use in damp locations.
Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains
carbon monoxide. This is a poison you cannot see or smell.
NEVER use inside a home or garage, EVEN IF doors and windows are open.
Only use OUTSIDE and far away from windows, doors, and vents.
Do not use E85 fuel.
7 — English
SYMBOLS
FUEL WARNING
No smoking when filling with gasoline.
Do not overfill. Full level is 1 in. below
the top of the fuel neck. Stop the en-
gine for five minutes before refueling to
avoid the heat from the muffler igniting
fuel vapors.
ENGINE LUBRICANT WARNING
You must add lubricant before first operating the generator. Always
check the lubricant level before each operation. The lubricant
level should always register between the hatched areas on the
dipstick. The unit is equipped with a sensor which will automati-
cally shut off the engine if the lubricant level falls below a safe limit.
GROUNDING WARNING
National Electric Code requires generator to be grounded to an approved earth ground.
HOT SURFACE WARNING
Do not touch the muffler or aluminum
cylinder of the engine. They are very HOT
and will cause severe burns. Don’t put
any flammable or combustible materials
in the direct path of the exhaust.
Product does not include ground rod or copper wire. National Electric Code requires generator to be
properly grounded to an approved earth ground. Call an electrician for local grounding requirements.
Le produit ne comprend pas de piquet de terre ou de fil en cuivre. Le code electrique americain (National
Electric Code) requiert un générateur pour une bonne mise à la terre approuvée. Appeler un électricien
pour connaître les exigences locales de mise à la terre.
El producto no incluye el alambre de cobre ni la barra de conexión a tierra. Los Reglamentos Nacionales
de Electricidad exigen que el generador esté debidamente conectado a una tierra aprobada.
Comuniquese con un electrista para todo lo relacionado con los requistos de conexión a tierra.
WARNING
ADVERTENCIA
AVERTISSEMENT
940513008-02
Risk of Fire. Check for any fuel overflow or leaking. Stop the engine before refueling.
DANGER PELIGRO
Risque d’incendie. Vérifier l'absence de débordement ou de fuite de carburant.
Arrêter le moteur avant de fair le plein.
Riesgo de incendio. Revise si hay algún derrame o fuga de combustible. Apague el
motor antes de poner combustible.
940974007-03
EXTENSION CORD CABLE SIZE
Refer to the table below to ensure the cable size of the extension cords you use are capable of carrying the required load.
Inadequate size cables can cause a voltage drop, which can damage the appliance and overheat the cord.
Current in
Amperes
Load in Watts Maximum Allowable Cord Length
At 120V At 240V #8 Wire #10 Wire #12 Wire #14 Wire #16 Wire
2.5 300 600 1000 ft. 600 ft. 375 ft. 250 ft.
5 600 1200 500 ft. 300 ft. 200 ft. 125 ft.
7.5 900 1800 350 ft. 200 ft. 125 ft. 100 ft.
10 1200 2400 250 ft. 150 ft. 100 ft. 50 ft.
15 1800 3600 150 ft. 100 ft. 65 ft.
20 2400 4800 175 ft. 125 ft. 75 ft.
25 3000 6000 150 ft. 100 ft.
30 3600 7200 125 ft. 65 ft.
40 4800 9600 90 ft.
ELECTRICAL
8 — English
ELECTRICAL
GENERATOR CAPACITY
Make sure the generator can supply enough continuous (run-
ning) and surge (starting) watts for the items you will power
at the same time. Follow these simple steps.
1. Selecttheitemsyouwillpoweratthesametime.
2. Totalthecontinuous(running)wattsoftheseitems.This
is the amount of power the generator must produce to
keep the items running. See the wattage reference chart
at right.
3. Estimatehowmanysurge(starting)wattsyouwillneed.
Surge wattage is the short burst of power needed to
start electric motor-driven tools or appliances such as a
circular saw or refrigerator. Because not all motors start
at the same time, total surge watts can be estimated by
adding only the item(s) with the highest additional surge
watts to the total rated watts from step 2.
Example:
Tool or Appliance
Running
Watts*
Additional
Starting Watts*
Refrigerator 700 1350
Portable Fan 40 120
Laptop 250 250
46 in. Flat Panel
Television
190 190
Light (75 Watts) 75 75
1255 Total
Running Watts
1350 Highest
Starting Watts
Total Running Watts 1255
Highest Starting Watts + 1350
Total Starting Watts Needed 2605
ELECTRIC MOTOR LOADS
It is characteristic of common electric motors in normal operation to draw up to six times their running current while starting.
This table may be used to estimate the watts required to start electric motors; however, if an electric motor fails to start or
reach running speed, turn off the appliance or tool immediately to avoid equipment damage. Always check the requirements
of the tool or appliance being used compared to the rated output of the generator.
Motor Size (H.P.) Running Watts
Watts Required to Start Motor
Universal Capacitor Split Phase
1/8 275 N/A 850 1200
1/6 275 600 850 2050
1/4 400 800 1050 2400
1/3 450
950
1350 2700
1/2 600 1000 1800 3600
3/4 850 1200 2600
1 1100 N/A 3300
NOTICE:
Operating voltage and frequency requirement of all electronic equipment should be checked prior to plugging them
into this generator. Damage may result if the equipment is not designed to operate within a +/- 10% voltage variation,
and +/- 3 hz frequency variation from the generator name plate ratings. To avoid damage, always have an additional
load plugged into the generator if solid state equipment (such as a television set) is used. A power line conditioner is
recommended for some solid state applications.
9 — English
ELECTRICAL
FEATURES
Application/Equipment
Estimated
Starting
Watts*
Estimated*
Additional
Starting
Watts
Emergency / Home Standby
Lights (qty. 4 x 75 W) 300 300
Refrigerator 700 1350
46 in. Flat Panel Television 190 190
Satelite Receiver 250 250
Portable Fan 40 120
Heater 1300 1300
Laptop 250 250
Slow Cooker 270 270
Radio 50 50
Job Site
ElectricDrill−3/8in. 600 1000
Quartz Halogen Work Light 1000 1000
Reciprocating Saw 960 1920
CircularSaw−7-1/4in. 1400 2300
MiterSaw−10in. 1800 1800
AirCompressor−1/4HP 970 1600
AirlessSprayer−1/3HP 600 1200
*Wattages listed are approximate. Check tool or appliance for actual wattage.
POWER MANAGEMENT
To prolong the life of the generator and attached devices,
it is important to take care when adding electrical loads to
the generator. There should be nothing connected to the
generator outlets before starting its engine. The correct and
safe way to manage generator power is to sequentially add
loads as follows:
1. With nothing connected to the generator, start the engine
as described later in this manual.
2. Plug in and turn on the first load, preferably the largest
load you have.
3. Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly).
4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
Never add more loads than the generator capacity. Take
special care to consider surge loads in generator capacity
as previously described.
NOTICE:
Do not overload the generator’s capacity. Exceeding the
generator’s wattage/amperage capacity may damage
the generator and/or electrical devices connected to it.
PRODUCT SPECIFICATIONS
ENGINE
Engine Type .........................Single Overhead Cam (SOHC)
Spark Plug .......................................................... LD A7RTC
Engine Lubricant Volume.......................................13.52 oz.
GENERATOR
Rated Voltage .........................................120 V AC/12 V DC
Rated Amps .............................................15 A AC/7.5 A DC
Rated Running Watts .............................................1,800 W
Starting Watts .........................................................2,200 W
Rated Frequency ........................................................ 60 Hz
10 — English
FEATURES
KNOW YOUR GENERATOR
See Figure 1.
The safe use of this product requires an understanding of the
information on the product and in this operator’s manual as
well as a knowledge of the project you are attempting. Before
use of this product, familiarize yourself with all operating
features and safety rules.
120 V AC RECEPTACLES
Your generator has two single phase, 60 Hz outlets that are
120 Volt AC, 20 Amp receptacles. These can be used for
operating appropriate appliances, electrical lighting, tools,
and motor loads.
AIR FILTERS
The air filters help to limit the amount of dirt and dust drawn
into the unit during operation.
AUTO IDLE SWITCH
The auto idle switch is used to control the speed of the
engine and conserve fuel. When the switch is in the ON (I)
position and no appliances are connected to the unit, the
engine will idle. If an appliance is added, the engine speed
will increase to power the item. If the appliance is removed,
the engine will return to idle.
BATTERY CHARGING CABLE
The battery charging cable makes it easy to charge 12 Volt
lead acid batteries with the generator.
NOTE: Only use battery charging cable to charge vented
wet lead acid batteries.
CARRY HANDLES
The generator is equipped with two carry handles for easy
transport. Both handles should be used to carry the gen-
erator.
DC CIRCUIT BREAKER
The circuit breaker is provided to protect the generator
against electrical overload.
DC RECEPTACLE
Your generator has a 12 volt, 7.5 Amp DC receptacle for
charging lead acid batteries.
ENGINE/CHOKE LEVER
The engine/choke lever is used when starting, stopping, and
running the engine.
WARNING:
The 12 V DC receptacle is designed to charge vented
wet lead acid batteries only. Other types of batteries may
burst, causing personal injury and damage.
FUEL TANK
The fuel tank has a capacity of 1.0 gallon.
GROUND TERMINAL
The ground terminal is used to assist in properly ground-
ing the generator to help protect against electrical shock.
Consult with a local electrician for grounding requirements
in your area.
LED DISPLAY
LEDs provide feedback to indicate whether the generator is
in use, overloaded, or in need of lubricant.
OIL CAP/DIPSTICK
Remove the oil fill cap to check and add lubricant to the
generator when necessary.
PARALLEL KIT TERMINALS
The non-polarized parallel kit terminals are used with a
parallel kit (sold separately) that will allow generators to be
linked together to increase output.
NOTE: Read and understand the parallel kit’s instructions
prior to use. Kit is for usage with this unit only.
RESET BUTTON
The reset button is used to restore power if an overload
occurs. To restore power, depress the reset button.
RETRACTABLE HANDLE
The generator is equipped with a retractable handle that can
be adjusted for storage and transportation.
STARTER GRIP AND ROPE
The starter grip and rope is used (along with the engine/
choke lever) to start the generator’s engine.
11 — English
UNPACKING
This product has been shipped completely assembled.
Carefully remove the product and any accessories from
the box. Make sure that all items listed in the packing list
are included.
WARNING:
Do not use this product if any parts on the Packing List
are already assembled to your product when you unpack
it. Parts on this list are not assembled to the product by
the manufacturer and require customer installation. Use
of a product that may have been improperly assembled
could result in serious personal injury.
Inspect the product carefully to make sure no breakage
or damage occurred during shipping.
Do not discard the packing material until you have
carefully inspected and satisfactorily operated the
product.
If any parts are damaged or missing, please call
1-800-860-4050 for assistance.
PACKING LIST
Generator
Battery Charging Cable
Engine Lubricant (SAE 10W 30)
Screwdriver
Funnel
Operator’s Manual
ASSEMBLY
WARNING:
If any parts are damaged or missing do not operate this
product until the parts are replaced. Use of this product
with damaged or missing parts could result in serious
personal injury.
WARNING:
Do not attempt to operate the generator until assembly
is complete. Failure to comply could result in possible
serious personal injury.
WARNING:
Do not attempt to modify this product or create acces-
sories not recommended for use with this product. Any
such alteration or modification is misuse and could result
in a hazardous condition leading to possible serious
personal injury.
12 — English
OPERATION
DANGER:
Carbon Monoxide. Using a generator indoors CAN KILL
YOU IN MINUTES.
Generator exhaust contains high levels of carbon
monoxide (CO), a poisonous gas you cannot see or smell.
If you can smell the generator exhaust, you are breathing
CO. But even if you cannot smell the exhaust, you could
be breathing CO.
Never use a generator inside homes, garages,
crawlspaces, or other partly enclosed areas. Deadly
levels of carbon monoxide can build up in these
areas. Using a fan or opening windows and doors
does NOT supply enough fresh air.
ONLY use a generator outdoors and far away from
open windows, doors, and vents. These openings
can pull in generator exhaust.
Even when you use a generator correctly, CO may
leak into the home. ALWAYS use a battery-powered or
battery-backup CO alarm in the home.
If you start to feel sick, dizzy, or weak after the generator
has been running, move to fresh air RIGHT AWAY. See
a doctor. You could have carbon monoxide poisoning.
DANGER:
Failure to properly ground generator can result in
electrocution, especially if the generator is equipped with
a wheel kit. National Electric Code requires generator to
be properly grounded to an approved earth ground. Call
an electrician for local grounding requirements.
WARNING:
Do not allow familiarity with this product to make you
careless. Remember that a careless fraction of a second
is sufficient to inflict serious injury.
WARNING:
Do not use any attachments or accessories not
recommended by the manufacturer of this product. The
use of attachments or accessories not recommended
can result in serious personal injury.
APPLICATIONS
This generator is designed to supply electrical power for
operating compatible electrical lighting, appliances, tools,
and motor loads.
BEFORE OPERATING THE UNIT
Only use OUTSIDE and far away from windows, doors,
and vents.
NEVER use inside a home or garage, EVEN IF doors and
windows are open.
Always position the generator on a flat firm surface.
SPECIAL REQUIREMENTS:
There may be General or State Occupational Safety and
Health Administration (OSHA) regulations, local codes or
ordinances that apply to the intended use of the generator.
Please consult a qualified electrician, electrical inspector, or
the local agency having jurisdiction:
In some areas, generators are required to be registered
with local utility companies.
If the generator is used at a construction site, there may
be additional regulations which must be observed.
LED DISPLAY
See Figure 2.
Power:
The power indicator will light when the generator is on and
the receptacles are operational.
NOTE: If the generator is overloaded, the power indicator
light will go off.
Overload:
The overload indicator will light if the generator’s wattage/
amperage capacity is exceeded. To reset the generator, re-
move all loads from the generator and press the reset button
(see fig. 1). Add loads back to the generator one at a time
being careful not to exceed the generators wattage rating.
Lubricant:
The oil indicator will light and the engine will automatically
shut off whenever the lubricant level in the engine becomes
low. The engine may not be restarted until sufficient engine
lubricant has been added to the generator.
NOTE: It is normal for the indicator lights to illuminate and/
or blink each time the engine is started. Once the engine
warms up, the lights should default to the pattern above.
CHECKING/ADDING LUBRICANT
See Figure 3.
NOTICE:
Attempting to start the engine before it has been properly
filled with lubricant will result in equipment failure.
Engine lubricant has a major influence on engine perfor-
mance and service life. For general, all-temperature use,
SAE 10W-30 is recommended. Always use a 4-stroke motor
lubricant that meets or exceeds the requirements for API
service classification SJ.
13 — English
OPERATION
NOTE: Non-detergent or 2-stroke engine lubricants will
damage the engine and should not be used.
Loosen the screws at the side of the engine cover.
Remove cover and set aside.
Unscrew the oil cap/dipstick and remove.
Wipe dipstick clean and re-seat in hole; do not re-thread.
Remove dipstick again and check lubricant level.
Lubricant level should fall between the minimum and
maximum marks on the dipstick.
If level is low, add engine lubricant until the fluid level
rises between the minimum and maximum marks on the
dipstick.
Replace and secure the oil cap/dipstick.
USING FUEL STABILIZER
Fuel gets old, oxidizes, and breaks down over time. Adding
a fuel stabilizer (not included) extends the usable life of fuel
and helps prevent deposits from forming that can clog the
fuel system. Follow fuel stabilizer manufacturer’s directions
for correct ratio of stabilizer to fuel.
Mix fuel stabilizer and gasoline prior to filling the tank
by using a gas can or other approved fuel container and
shaking gently to combine.
NOTE: To control the amount of fuel stabilizer being added
to the engine, always mix fuel stabilizer with gasoline
before fueling the tank rather than adding fuel stabilizer
directly into the generator’s fuel tank.
Replace and secure the fuel tank cap.
Start and run the engine for at least 5 minutes to allow
stabilizer to treat the entire fuel system.
OXYGENATED FUELS
NOTICE:
Do not use E15 or E85 fuel (or fuel containing greater
than 10% ethanol) in this product. It is a violation of
federal law and will damage the unit and void your
warranty.
Fuel system damage or performance problems resulting
from the use of an oxygenated fuel containing more than
the percentage of oxygenates stated below are not covered
under warranty.
Ethanol. Gasoline containing up to 10% ethanol by volume
(commonly referred to as E10) is acceptable. E15 and E85
are not.
CHECKING/ADDING FUEL
See Figure 4.
WARNING:
Gasoline and its vapors are highly flammable and ex-
plosive. To prevent serious personal injury and property
damage, handle gasoline with care. Keep away from igni-
tion sources, handle outdoors only, do not smoke while
adding fuel, and wipe up spills immediately.
When adding gas to the generator, make sure the unit is
sitting on a flat, level surface. If the engine is hot, let the
generator cool before adding gas. ALWAYS fill the fuel tank
outdoors with the machine turned off.
Remove the fuel cap.
Fill the fuel tank to 1 in. below the top of the fuel neck.
Replace and secure the fuel cap.
NOTE: Always use unleaded gasoline with a pump octane
rating of 86 or higher. Never use old, stale, or contaminated
gasoline, and do not use an oil/gas mixture. Do not allow dirt
or water into the fuel tank. Do not use E85 fuel.
STARTING THE ENGINE
See Figures 5 - 7.
NOTICE:
On a level surface with the engine off, check the lubricant
level before each use of the generator.
NOTE: If location of generator is not level, the unit may not
start or may shut down during operation.
NOTICE:
Do not place the generator directly on the ground when
using the unit in grassy areas or in areas with dense
vegetation. Doing so could result in grass discoloration
and/or localized soil damage.
Unplug all loads from the generator.
Place the auto idle switch in the off position.
Slide the engine/choke lever to the start (center) position.
NOTE: When the engine/choke lever is in the start
(center) position, the fuel will flow from the fuel tank to
the engine. If engine is warm, move the engine/choke
lever right to the run (restart) position.
Pull the starter grip and rope until the engine runs
(a maximum of 6 times).
NOTE: Do not allow the grip to snap back after starting;
return it gently to its original place. Initial starting of the
unit may require additional pulls to prime the fuel pump.
Allow the engine to run for 15-30 seconds, then move
the engine/choke lever right to the run position.
14 — English
OPERATION
STOPPING THE ENGINE
See Figures 5 - 6.
Remove any load from the generator.
Place the engine/choke lever in the off position.
To stop the engine in an emergency situation:
Put the engine/choke lever in the off position.
WARNING:
While operating and storing, keep at least 3 feet of clear-
ance on all sides of this product, including overhead.
Allow a minimum of 30 minutes of “cool down” time
before storage. Heat created by muffler and exhaust
gases may be hot enough to cause serious burns and /
or ignite combustible objects.
USING THE BATTERY CHARGING CABLE
See Figure 8.
WARNING:
The 12 V DC receptacle is designed to charge vented
wet lead acid batteries only. Other types of batteries may
burst, causing personal injury and damage.
NOTICE:
The 12 V DC receptacle provides continuous charge. Do
not overcharge battery or leave battery unattended. Doing
so may cause damage to the battery.
NOTICE:
Do not use the generator to jump start vehicles. Doing
so could result in damage to the vehicle or it’s electrical
components.
Using the battery clamps, connect the battery charging
cable assembly to the battery terminal. Connect the
red wire to the positive (+) terminal first, then connect
the black wire to the negative (–) terminal. Make sure all
connections are secure.
NOTE: Be careful not to short across the terminals when
installing. Shorting the terminals together can cause
sparks, damage to the battery or generator, or even burns
or explosions.
Connect the battery charging cable assembly to the
12 V DC receptacle.
Start the generator.
NOTE: The AC receptacles can be used while the DC
receptacle is in use.
The battery will become slightly warm to the touch while
charging. This is normal and does not indicate a problem.
NOTE: Only use battery charging cable assembly to
charge vented wet lead acid batteries.
When batteries become fully charged, disconnect
the battery charging cable assembly from the battery.
Disconnect the negative (black) wire first, then the positive
(red) wire, being careful not to short across the terminals.
Always abide by the safety warnings provided with the
battery.
NOTE: Most batteries will be completely charged after
30 to 120 minutes. However, it is highly recommended
that you refer to your battery manufacturer’s instructions
for specific charge times.
Unplug battery charging cable assembly and store for
later use.
MOVING THE GENERATOR
See Figure 9.
Place the auto idle switch in the off position. At the off
position, the fuel valve will be closed and prevent any gas
flow.
Allow 30 minutes of “cool down” time before storing the
machine.
Pull the retractable handle out.
Facing the front of the generator, grasp the folding handle
firmly with one hand.
Lift the generator toward you until it balances on the
wheels.
Turn around and pull the unit along behind you to the
desired location.
Lower the generator until it sits securely on a flat surface.
HIGH ALTITUDE OPERATION
Specific modifications are needed for high-altitude operation.
Please contact your authorized service center for important
information regarding these modifications. Operating this
engine without the proper altitude modification may increase
the engine’s emissions and decrease fuel economy and
performance.
15 — English
MAINTENANCE
Tilt the generator to the side and allow lubricant to drain
from the oil fill hole into an approved container.
NOTE: Drain the lubricant while the engine is still warm
but not hot. Warm lubricant will drain quickly and more
completely.
WARNING:
Do not change engine lubricant while it is hot. Accidental
contact with hot engine lubricant could result in serious
burns.
Return the generator to an upright position and refill with
lubricant following the instructions in the Checking/
Adding Lubricant section previously in this manual.
For amount of lubricant needed to refill, see Product
Specifications earlier in this manual or the accompanying
engine manual, if applicable.
Replace and secure the oil cap/dipstick.
Reinstall the engine cover. Replace the screw and tighten
securely.
NOTE: Used lubricant should be disposed of at an approved
disposal site. See your local retailer for more information.
SPARK PLUG REPLACEMENT
See Figure 13.
The spark plug must be properly gapped and free of deposits
in order to ensure proper engine operation. To check:
Remove the spark plug cover.
Remove the spark plug cap.
Clean any dirt from around base of spark plug.
Remove spark plug using spark plug wrench.
Inspect spark plug for damage, and clean with a wire
brush before reinstalling. If insulator is cracked or
chipped, spark plug should be replaced. For replacement
spark plug, see Product Specifications earlier in this
manual or the accompanying engine manual, if applicable.
Measurepluggap.Thecorrectgapis0.024−0.028in.
(0.60-0.70 mm). To widen gap, if necessary, carefully
bend the ground (top) electrode. To lessen gap, gently
tap ground electrode on a hard surface.
Seat spark plug in position; thread in by hand to prevent
cross-threading.
Tighten with wrench to compress washer. If spark plug
is new, use 1/2 turn to compress washer appropriate
amount. If reusing old spark plug, use 1/8 to 1/4 turn for
proper washer compression.
NOTE: An improperly tightened spark plug will become
very hot and could damage the engine.
NOTICE:
Be careful not to cross-thread the spark plug. Cross-
threading will seriously damage the product.
WARNING:
When servicing, use only identical replacement parts.
Use of any other parts could create a hazard or cause
product damage.
WARNING:
Always wear eye protection with side shields marked to
comply with ANSI Z87.1. Failure to do so could result in
objects being thrown into your eyes, resulting in possible
serious injury.
GENERAL MAINTENANCE
Keep the generator in a clean and dry environment where it
is not exposed to dust, dirt, moisture, or corrosive vapors.
Do not allow the cooling air slots in the generator to become
clogged with foreign material such as leaves, etc.
Do not use a garden hose to clean the generator. Water
entering the fuel system or other internal parts of the unit can
cause problems that will decrease the life of the generator.
To clean the unit:
Use a soft bristle brush and/or vacuum cleaner to loosen
and remove dirt and debris.
Clean air vents with low pressure air that does not exceed
25 psi.
Wipe the exterior surfaces of the generator with a damp cloth.
CHECKING/CLEANING AIR FILTER
See Figures 10 - 11.
For proper performance and long life, keep air filter clean.
Loosen the screws on the side of the engine cover.
Remove cover and set aside.
Loosen the screw in the center of the air filter cover and
turn the cover 1/4 turn clockwise, pulling the cover down
and off the unit. Remove air filter cover and set aside.
Remove both the large and the small air filters.
Wash the air filters with warm, soapy water. Rinse and
squeeze to dry.
Reinstall the air filters.
NOTE: Make sure the filters are seated properly inside
the generator. Installing the filters incorrectly will allow
dirt to enter the engine, causing rapid engine wear.
Reinstall the air filter cover. Tighten screw to secure.
Reinstall the engine cover. Tighten screws to secure.
CHANGING ENGINE LUBRICANT
See Figure 12.
For best performance, engine lubricant should be changed
after every 100 hours or 6 months of operation.
Loosen the screw at the top of the engine cover. Remove
cover and set aside.
Remove the oil fill cap/dipstick.
16 — English
MAINTENANCE
DRAINING FUEL TANK/CARBURETOR
See Figures 14 - 15.
To help prevent gum deposits in the fuel system, drain the
fuel from the tank and carburetor before storing.
DRAINING THE FUEL TANK:
NOTICE:
Remove all lubricant from the unit before draining the fuel
tank. Failure to do so could cause damage to the unit.
Remove the fuel cap.
Tilt the generator and allow fuel to drain from the fuel tank
into an approved container.
When the fuel has drained from the tank, replace the fuel
cap.
DRAINING THE CARBURETOR:
Loosen the screws at the top of the engine cover. Remove
cover and set aside.
Place the engine/choke lever in the run position.
Position a suitable container under the carburetor drain
screw to catch fuel; loosen the screw.
Allow fuel to drain completely into container.
Retighten drain screw securely.
Place the engine/choke lever in the off position.
NOTE: Consult hazardous waste management guidelines in
your area for the proper way to dispose of used fuel.
TRANSPORTING
Place the engine/choke lever in the off position.
Make sure engine and exhaust of unit is cool.
Keep unit level to prevent fuel spillage.
Do not drop or strike unit or place under heavy objects.
MAINTENANCE SCHEDULE
NOTE: If a separate engine manual is provided for this generator, please follow the maintenance schedule provided in the engine
manual instead of the maintenance information listed below.
Before
each use
After 1st month
or 20 hours of
operation
Every 3 months
or 50 hours of
operation
Every 6 months
or 100 hours
of operation
Every year or
after 300 hours
of operation
Check Engine Lubricant
Change Engine Lubricant
2
Check Air Filter
Clean Air Filter
Change Air Filter
2
Check/Adjust Spark Plug
Replace Spark Plug
2
Check/Adjust Idle Speed
Check/Adjust Valve
Clearance
1,2
Clean Fuel Tank and Filter
1,2
Check Fuel Hose
Fuel Filter Inspect Replace
Check All Hose
Connections
Inspect Fuel Tank Vapor
Vent (If Equipped)
Inspect Carbon Canister
(CARB Models Only)
1. These items should only be carried out by an authorized service center.
2. See engine manual for maintenance schedule for this item.
NOTE: Maintenance should be performed more frequently when generator is used in dusty areas.
When generator has exceeded the maximum figures specified in the table, maintenance should still be cycled according
to the intervals of time or hours stated herein.
17 — English
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE SOLUTION
Engine will not start. Engine/choke lever is in run position.
No fuel.
Stale gasoline or water in gasoline.
Lubricant level is low.
Spark plug faulty, fouled, or improperly
gapped.
Engine stored without treating or
draining gasoline, or refueled with bad
gasoline.
Dirty fuel filter.
Move engine/choke lever to start position.
Fill fuel tank.
Drain entire system and refill with fresh
fuel.
Check engine lubricant level and fill, if
necessary.
Replace spark plug.
Drain fuel and carburetor. Refuel with
fresh gasoline.
Replace fuel filter or contact authorized
service center or contact authorized
service center.
Engine lacks power. Engine stored without treating or
draining gasoline, or refueled with bad
gasoline.
Dirty air filter.
Drain fuel and carburetor. Refuel with
fresh gasoline. If problem continues,
contact your nearest authorized service
center.
Clean or replace as needed.
DC receptacle does not work. Circuit protector engaged
Item plugged in is defective.
Remove any load from the generator.
Turn the auto idle switch to off, then
depress the DC circuit breaker.
Try a different item.
AC receptacle does not work. Item plugged in is defective. Try a different item.
Generator stops. Generator is overloaded. Remove loads and press the reset
button.
If problem persists after trying the above solutions, contact your nearest authorized service center for assistance.
The following symptoms may indicate problems that will affect the emissions level of the unit:
Hard starting or stalling after starting
Rough idle
Misfiring or backfiring under load
Afterburning (backfiring)
Black exhaust smoke or high fuel consumption
If you encounter any of these symptoms, have the unit inspected and repaired by the nearest authorized service center.
18 — English
WARRANTY
YOUR WARRANTY RIGHTS AND OBLIGATIONS
The California Air Resources Board, United Sates Environmental Protection
Agency (EPA), and Zhejiang ZhongJian Technology Co., Ltd. are pleased
to explain the emissions control system warranty on your 2012 small off-
road engine (SORE). In California, new SOREs must be designed, built
and equipped to meet the State’s stringent anti-smog standards. Zhejiang
ZhongJian Technology Co., Ltd. must warrant the emissions control system
on your SOREs for the periods of time listed below provided there has been
no abuse, neglect or improper maintenance of your SOREs.
Your emission control system may include parts such as the carburetor,
fuel tanks, fuel caps, fuel lines, the ignition system, and catalytic converter.
Also included may be hoses, belts, clamps, connectors and other emission-
related assemblies.
Where a warrantable condition exists, Zhejiang ZhongJian Technology
Co., Ltd. will repair your small off-road engine at no cost to you including
diagnosis, parts and labor.
MANUFACTURER’S WARRANTY COVERAGE:
The emissions control system is warranted for two years. If any emissions-
related part on your engine is defective, the part will be repaired or replaced
by Zhejiang ZhongJian Technology Co., Ltd.
OWNER’S WARRANTY RESPONSIBILITIES:
As the SORE owner, you are responsible for the performance of the
required maintenance listed in your owner’s manual. Zhejiang ZhongJian
Technology Co., Ltd. recommends that you retain all receipts covering
maintenance on your SORE, but Zhejiang ZhongJian Technology Co.,
Ltd. can not deny warranty solely for the lack of receipts or for your
failure to ensure the performance of all scheduled maintenance.
As the SORE owner, you should however be aware that Zhejiang
ZhongJian Technology Co., Ltd. may deny your warranty coverage if your
SORE or a part has failed due to abuse, neglect, improper maintenance
or unapproved modifications.
You are responsible for presenting your SORE to distribution center
or service center authorized by Zhejiang ZhongJian Technology Co.,
Ltd. as soon as the problem exists. The warranty repairs should be
completed in a reasonable amount of time, not to exceed 30 days.
If you have any questions regarding your warranty coverage, you should
contact Zhejiang ZhongJian Technology Co., Ltd. customer service
representative at 1-866-340-3912.
DEFECTS WARRANTY COVERAGE
Adopted by the Air Resources Board, Zhejiang ZhongJian Technology Co.,
Ltd. warrants to the ultimate purchaser and each subsequent purchaser that
the small off-road engine (SORE) (1) has been designed, built and equipped
so as to conform with all applicable regulations; and (2) is free from defects
in materials and workmanship that cause the failure of a warranted part
to conform with those regulations as may be applicable to the terms and
conditions stated below.
(A) The warranty period begins on the date the engine is delivered to an
ultimate purchaser. The warranty period is two years.
(B) Subject to certain conditions and exclusions as stated below, the
warranty on emissions related parts is as follows:
(1) Any warranted part that is not scheduled for replacement as required
maintenance in your Owner’s Manual is warranted for the warranty
period stated above. If the part fails during the period of warranty
coverage, the part will be repaired or replaced by Zhejiang ZhongJian
Technology Co., Ltd. according to Subsection (4) below. Any such
part repaired or replaced under warranty will be warranted for the
remainder of the period.
(2) Any warranted part that is scheduled only for regular inspection in
your Owner’s Manual is warranted for the warranty period stated
above. Any such part repaired or replaced under warranty will be
warranted for the remaining warranty period.
(3) Any warranted part that is scheduled for replacement as required
maintenance in your Owner’s Manual is warranted for the period
of time before the first scheduled replacement date for that part. If
the part fails before the first scheduled replacement, the part will
be repaired or replaced by Zhejiang ZhongJian Technology Co.,
Ltd. according to Subsection (4) below. Any such part repaired or
replaced under warranty will be warranted for the remainder of the
period prior to the first scheduled replacement point for the part.
(4) Repair or replacement of any warranted part under the warranty
provisions herein must be performed at a warranty station at no
charge to the owner.
(5) Notwithstanding the provisions herein, warranty services or repair
will be provided at all of our distribution centers that are franchised
to service the subject engines.
(6) The engine owner must not be charged for diagnostic labor that
leads to the determination that a warranted part is in fact defective,
provided that such diagnostic work is performed at a warranty
station.
(7) Zhejiang ZhongJian Technology Co., Ltd. is liable for damages to
other engine components proximately caused by a failure under
warranty of any warranted part.
(8) Throughout the engine warranty period stated above, Zhejiang
ZhongJian Technology Co., Ltd. will maintain a supply of warranted
parts sufficient to meet the expected demand for such parts.
(9) Any replacement part may be used in the performance of any
warranty maintenance or repairs and must be provided without
charge to the owner. Such use will not reduce the warranty
obligations of Zhejiang ZhongJian Technology Co., Ltd.
(10) Add-on or modified parts that are not exempted by the Air Resources
Board may not be used. The use of any non-exempted add-on
or modified parts by the ultimate purchaser will be grounds for
disallowing a warranty claims. Zhejiang ZhongJian Technology
Co., Ltd. will not be liable to warrant failures of warranted parts
caused by the use of a non-exempted add-on or modified part.
(11) The manufacturer issuing the warranty shall provide any documents
that describe that manufacturer’s warranty procedures or policies
within five working days of request by the Air Resources Board.
EMISSION WARRANTY PARTS LIST
The repair or replacement of any warranted part otherwise eligible for
warranty coverage may be excluded from such warranty coverage if
Zhejiang ZhongJian Technology Co., Ltd. demonstrates that the engine has
been abused, neglected, or improperly maintained, and that such abuse,
neglect, or improper maintenance was the direct cause of the need for
repair or replacement of the part. That notwithstanding, any adjustment of a
component that has a factory installed, and properly operating, adjustment
limiting device is still eligible for warranty coverage. The following emissions
warranty parts for each engine family list is covered.
For engine family CZJTS.1061CA :
(1) Fuel Metering System:
(a) Gasoline carburetor assembly and its internal components
(b) Carburetor gaskets
(c) Fuel tank
(d) Fuel Line
(e) Fuel Line Fittings
(f) Clamps
(2) Air Induction System including:
(a) Intake pipe/manifold
(b) Air cleaner
(3) Ignition System including:
(a) Spark plug
(b) Ignition coil
(4) Catalytic Muffler Assembly (if so equipped) including:
(a) Muffler gasket
(b) Exhaust manifold
(c) Catalytic converter
(5) Crankcase Breather Assembly including:
(a) Breather connection tube.
(6) Fuel tank evaporative emissions control system including:
(a) Purge Valves
(b) Carbon Canister
(c) Canister Mounting Brackets
(d) Fuel Cap
(e) Fuel Tank
(7) Miscellaneous items Used in Above Systems including:
(a) Switches
(b) Hoses, belts, connectors, and assemblies.
(8) Air injection system
(a) Pulse valve
CALIFORNIA AND EPA EMISSIONS CONTROL WARRANTY STATEMENT
19 — English
WARRANTY
Techtronic Industries North America, Inc. (herein
“Techtronic Industries”), warrants that each new engine
sold by it will be free, under normal use and service,
from defects in material and workmanship for a period
listed below from the date of sale to the original retail
purchaser. Techtronic Industries obligation under this
Limited Warranty shall be limited to the repair and
replacement, at Techtronic Industries option, of any part or
parts which upon examination is/are found, in Techtronic
Industries judgment, to have been defective in material or
workmanship. It shall be a condition of Techtronic Industries
obligation under this Limited Warranty that Techtronic
Industries, directly or through one of its Distributors or
Service Centers authorized to service the particular engine
involved, receive prompt notice of any warranty claim
and that the engine or the part or parts claimed to be
defective be promptly delivered, transportation prepaid,
to such Distributor or Service Center for inspection and
repair. All repairs qualifying under this Limited Warranty
must be performed by Techtronic Industries or one of its
authorized Distributors or Service Centers.
WARRANTY PERIODS:
158F Gasoline Engine (Private/Residential) Limited 2
year Warranty
158F Gasoline Engines (Commercial) Limited 90 Day
Warranty
The repair or replacement of any part or parts under this
Limited Warranty shall not extend the term of the engine
warranty beyond the original term as set forth above.
LIMITATIONS AND EXCLUSIONS: This Limited Warranty
shall not apply to:
1. Repair required because of prolonged storage including
damage caused by old or contaminated fuel in the fuel
tank, fuel lines, or carburetor, sticky valves or corrosion
and rust of engine parts.
2. Repair required due to overheating. (Most often caused
by overloaded or clogged or damaged or missing flywheel,
fan, inlet air passages, cooling fins, or air shrouds.)
3. Dirt or grit related wear caused by improper air cleaner
maintenance (most often resulting in worn piston, piston
LIMITED ENGINE WARRANTY
rings, cylinders, valves, valve guides, carburetor, or other
internal components).
4. Broken or scored parts caused by low oil level, dirty,
or improper grade of oil.
5. Engine tune-ups and normal maintenance service
including, but not limited to, valve adjustment, normal
replacement of service items, fuel, and lubricating oil, etc.
6. Any engine which has been subject to negligence,
misuse, accident, misapplication, or overspeeding.
7. Any engine that has been installed, repaired, or altered
by anyone in a manner which in Techtronic Industries sole
judgment adversely affects its performance or reliability.
8. Any engine which has been fitted with or repaired with
parts or components not manufactured or approved by
Techtronic Industries which in Techtronic Industries’ sole
judgment adversely affects its performance or reliability.
9. Instances when normal use has exhausted the life of
a component or an engine.
The customer is responsible for all transportation charges
in connection with any warranty work.
Techtronic Industries reserves the right to modify, alter,
or improve any engines or parts without incurring any
obligation to modify or replace any engine or parts
previously sold without such modification, alternation,
or improvement.
No person is authorized to give any other warranty or to
assume any additional obligation on Techtronic Industries’
behalf unless made in writing and signed by an officer of
Techtronic Industries.
THIS WARRANTY, TECHTRONIC INDUSTRIES
OBLIGATION HERE UNDER, ARE IN LIEU OF ANY
OTHER WARRANTIES OR OBLIGATIONS OF ANY
KIND, EXPRESSED OR IMPLIED, INCLUDING ANY
WARRANTIES OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE. THERE ARE NO
WARRANTIES WHICH EXTEND BEYOND THE
DESCRIPTION ON THE FACE HERE-OF. TECHTRONIC
INDUSTRIES SHALL IN NO EVENT BE LIABLE FOR
ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES.
IF YOU HAVE ANY QUESTIONS REGARDING YOUR WARRANTY RIGHTS AND RESPONSIBILITIES, CONTACT
YOUR NEAREST AUTHORIZED RYOBI SERVICE CENTER AT 1-800-860-4050.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61

Ryobi RYi2200A Mode d'emploi

Catégorie
Groupes électrogènes
Taper
Mode d'emploi
Ce manuel convient également à

dans d''autres langues