Extron electronics DTP T 3G-SDI 230 D Manuel utilisateur

Taper
Manuel utilisateur

Ce manuel convient également à

DTP T 3G-SDI D Series • Setup Guide
This setup guide provides instructions for an experienced installer to set up and operate the Extron DTP T 3G-SDI D series of
SDI extenders. The DTP T 3G-SDI 230 D and DTP T 3G-SDI 330 D products can transmit video, control, and audio (if applicable)
signals up to 230 feet (70 meters) and 330 feet (100 meters), respectively.
Installation
Step 1 — Prepare the Mounting Surface
NOTE: Use a UL-listed junction box with a depth of at least
3.0 inches (7.6 cm). Alternatively, the included mud ring
(MR 100) can be used.
For more information, see the full product user guide at
www.extron.com. The installation must comply with the
National Electrical Code and all applicable local codes.
a. Place the junction box against the installation surface and
mark the opening guidelines.
b. Cut out the material from the marked area.
c. Secure the junction box with 10-penny nails or #8 or #10 screws, leaving the front edge ush with the surface.
d. Run all required cables (see steps 4, 5, and 6) and secure them with cable clamps.
TIP: To ensure a proper t the unit in the junction box, do not install boots on TP cables and RJ-45 connectors.
Step 2 — Disconnect Power
Disconnect all equipment from power sources.
Step 3 — Connect Rear Panel Inputs to the Transmitter
A SDI input connector — Connect a coaxial cable to the output port of the SDI or HD-SDI video source.
B SDI Loop Thru connector — Connect a display to this BNC loop-through connector for local monitoring.
C Audio input connector — Connect an unbalanced stereo audio source to this 3.5 mm mini stereo jack.
NOTES:
The DTP T 3G-SDI D series of products do not embed this audio onto the SDI signal. Audio is transported
separately over the DTP connection.
AES/EBU digital audio is passed through with the supported SDI format.
Tx TxRx RxG
RS-232
IR
3G/SDI IN
L
O
O
P
T
H
R
U
AUDIO IN
OVER TP
DTP T 3G-SDI 330 D
OUT
12V
1.0A MAX
POWER
+–
CONFIG
DTP T 3G-SDI 230/330 D
Front Panel
DTP T 3G-SDI 230/330 D
Rear Panel
B
G
A
E
F
C
D
H
A SDI Input connector
B SDI Loop Thru connector
C Audio Input connector
D RS-232 and IR Over TP connector (page 2)
E USB Config port (page 2)
F TP Out connector (page 2)
G Power input connector (page 2)
H Power LED (page 3)
Wall Stud
Screws
or Nails
Signal
Output
Cable
Decorator-Style Faceplate
Extron
DTP T 3G-SDI 330 D
E
OVER TP
RS-232 IR
Tx
L
O
O
P
T
H
R
U
AUDIO IN
3G-SD I IN
Rx Tx RxG
2
DTP T 3G-SDI D Series • Setup Guide (Continued)
D RS-232 and IR Over TP — Plug an RS-232 or modulated IR device into
this RS-232 and IR Over TP pass-through port. Wire the cable as shown
to the right.
E USB Config port — Connect a PC to this USB mini-B port for device
conguration and rmware updates.
F TP Out connector — Connect the rear panel transmitter output (see
F
on page 1) to the rear panel receiver input using
shielded twisted pair (STP) cable.
ATTENTION:
Do not connect these outputs to a telecommunications or computer data network.
Ne connectez pas ces appareils à des données informatiques ou à un réseau de télécommunications.
Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or STP201 cable.
N’utilisez pas le câble AV Skew-FreeUTP version améliorée UTP23SF d’Extron ou le câble STP201.
For optimal performance, Extron highly recommends the following:
RJ-45 termination with STP cable must comply with TIA/EIA T568-B wiring standard for all connections. For more
information on cable wiring and termination, see the full product user guide at www.extron.com.
Use shielded twisted pair cable, 24 AWG solid conductor or better, with a minimum cable bandwidth of 400 MHz.
Use shielded RJ-45 plugs to terminate the cable.
Limit the use of RJ-45 patches. Overall transmission distance capabilities vary
depending on the number of patches used. If possible, limit the number of
patches to a maximum of 2.
If RJ-45 patches must be used in the system, shielded CAT 6 (or better) patches
are recommended.
G Power input connector — Plug the included external 12 VDC power supply into
either this 2-pole connector (see the illustration to the right for wiring information)
or the power input connector on the receiver (see the user guide of your respective
receiver for more information).
The unit can be powered either locally, with the included external 12 VDC power
supply, or over the DTP line by a locally powered receiver or switcher.
ATTENTION:
Extron recommends installing the DTP T 3G-SDI D into a grounded, UL-listed electrical junction box.
Extron recommande d’installer le DTP T 3G-SDI D dans un boîtier d’encastrement électrique mis à la terre,
listé UL.
Step 4 — Connect Outputs from the Receiver
The DTP T 3G-SDI D series is compatible with DTP 230 and DTP 330 receivers (sold separately).
a. Output connector — Connect a DisplayPort or HDMI cable between this port and the input port of the display. For
complete instructions on connecting receivers or switchers to outputs, see the user guide for the appropriate product at
www.extron.com.
b. Audio output — Connect a stereo audio device to this 3.5 mm mini stereo jack to receive the passed through
unbalanced audio.
c. RS-232 and IR Over TP connector — Plug an RS-232 or modulated IR device into the RS-232 and IR Over TP
pass-through port. Wire the connector as shown in step 3 above.
Step 5 — Final Installation
a. Make all connections and test the system for satisfactory operation.
b. At the power outlet, unplug the power supply.
c. Mount the transmitter into the wall box and attach the supplied decorator-style faceplate to the unit.
d. At the power outlet, reconnect the power supply. This can power up both the transmitter and receiver.
Ground
Transmit pin on connected unit
Receive pin on connected unit
Connected RS-232
and IR Device Pins
Receive pin on connected unit
Transmit pin on connected unit
Tx TxRx RxG
RS-232
IR
OVER TP
SECTION A–A
AA
Power Supply
Output Cord
Captive Screw
Connector
Ridges
Smooth
3/16"
(5 mm) Max.
3
DTP T 3G-SDI D Series • Setup Guide
3
DTP T 3G-SDI D Series • Setup Guide
Operation
After all devices are powered up, the system is fully operational. See the denitions of the power indications below.
Transmitter Power Indicator
H Power LED — This two-color front panel LED on both DTP T 3G-SDI 230 D and
DTP T 3G-SDI 330 D transmitters lights to indicate signal and power status as follows:
Amber — The unit is receiving power but no signal on the SDI input.
Green — The unit is receiving power and a signal is present on the SDI input.
Application Diagram
The following gure shows a typical application for the DTP T 3G-SDI 330 D transmitter.
DTP HDMI 330 Tx
AUDIO
INPUTS OVER DTP
RS-232
IR
Tx Rx Tx RxG
POWER
12V
0.7A MAX
SIG LINK
DTP OUT
DTP HDMI 330 Rx
OVER DTP
RS-232
IR
Tx Rx Tx RxG
LR
POWER
12V
0.7A MAX
AUDIO
SIG LINK
DTP IN
OUTPUTS
50-60 Hz
100-240V ~
2.0 A MAX
1
L
R
SIG LINK
OUT
SIG LINK
OUT
1
3
4
4
XTP
RS-232 IR
Tx Rx
RTSCTS
GTxRxG Tx Rx G
RS-232 IR
Tx Rx Tx RxG
Tx Rx G
Tx Rx Tx Rx
XTP
RESET
S/PDIF
OUT
DTP
XTP
DTP
XTP
DTP
EXP
+48V
MIC/LINE
1
1
3
2
4
2
3
4
LINK
LAN 2
LAN 1
LAN 3
HDBT
G
DTP
HDBT
2
1234
5
7
8
6
DTP CROSSPOINT 84
4
CLASS 2 WIRING
8/
R
RS-232 IR
Tx Rx Tx RxG
OVER TP
OVER TP
REMOTE
SIG LINK
IN
SIG LINK
IN
AUDIO INPUTS
AUDIO OUTPUTS
AMP OUTPUT
CONTROL
1234G
DIGITAL I/OCOM 3COM 2COM 1
S
DMP EXPANSION
SGG
1
1
2
2
C34C
INPUTS
-S G+S+V
PWR OUT = 6W
OUTPUTS
RS-232 IR
Tx Rx Tx RxG
1
LR
1
LR
3
LR
3
LR
5
LR
2
LR
4
LR
2
LR
4
LR
6
LR
IR/SERIALeBUSRELAYS
Tx TxRx RxG
RS-232
IR
3G/SDI IN
L
O
O
P
T
H
R
U
AUDIO IN
OVER TP
Extron
DTP T 3G-SDI 330 D
Transmitter
Flat Panel Display
CATx Cable
up to 230'
(70 m)
CATx Cable
up to 330'
(100 m)
Extron
DTP HDMI 330 Rx
Receiver
Extron
DTP HDMI 330 Tx
Receiver
HDMI
HDMI
Extron
DTP CrossPoint 84 IPCP SA
Scaling Presentation Matrix
3G
-SDI Camera
RS-232 / IR
3G-SDI
3G-SDI
Audio
Local Monitor
PC
Figure 1. A Typical DTP T 3G-SDI 330 D Application
LOCAL OUT
DVI-D
AUDIO
REMOTE
DDC
ROUTE
LOCAL
Tx Rx GTxRx
RS-232 IR
ON
12
H
Tx TxRx RxG
RS-232
IR
3G/SDI IN
L
O
O
P
T
H
R
U
AUDIO IN
OVER TP
DTP T 3G-SDI 330 D
OUT
12V
1.0A MAX
POWER
+–
CONFIG
DTP T 3G-SDI 230/330 D
Front Panel
DTP T 3G-SDI 230/330 D
Rear Panel
B
G
A
E
F
C
D
H
4
DTP T 3G-SDI D Series • Setup Guide
68-2683-50 Rev. C
05 17
Extron Headquarters
+800.633.9876 Inside USA/Canada Only
Extron USA - West Extron USA - East
+1.714.491.1500 +1.919.850.1000
+1.714.491.1517 FAX +1.919.850.1001 FAX
Extron Europe
+800.3987.6673
Inside Europe Only
+31.33.453.4040
+31.33.453.4050 FAX
Extron Asia
+65.6383.4400
+65.6383.4664 FAX
Extron Japan
+81.3.3511.7655
+81.3.3511.7656 FAX
Extron China
+86.21.3760.1568
+86.21.3760.1566 FAX
Extron
Middle East
+971.4.299.1800
+971.4.299.1880 FAX
Extron Korea
+82.2.3444.1571
+82.2.3444.1575 FAX
Extron India
1800.3070.3777
Inside India Only
+91.80.3055.3777
+91.80.3055 3737 FAX
© 2017 Extron Electronics All rights reserved. www.extron.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Extron electronics DTP T 3G-SDI 230 D Manuel utilisateur

Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues