Develco WISZB-137 Manuel utilisateur

Taper
Manuel utilisateur
a.
b.
b.
d.
e.
Bed Frame
Frame Window/
Door
Pipe
eng
Mounting
1. Clean the surface before mounting.
2. The Vibration Sensor should be mounted
on the surface using the double stick tape,
already applied on the back of the sensor.
Press rmly to secure sensor.
MOUNTING EXAMPLE 1: WINDOW
1. Clean the surface before mounting.
2. The Vibration Sensor should be mounted
on the window frame using the double
stick tape, already applied on the back of
the sensor. Press rmly to secure sensor.
Placement
Place the sensor indoors at a temperature
between 0-50°C.
In case of a weak or a bad signal, change
the location of the Vibration Sensor or
strengthen the signal with a smart plug.
The Vibration Sensor can be placed on
dierent surfaces indoors such as windows,
cabinets, chairs, tables, beds, pipes, a
compressor or anywhere else where
vibrations can give valuable insights.
When removing cover for battery change -
electrostatic discharge can harm electronic
components inside.
Always mount indoors as sensor is not
waterproof.
Getting started
1. Open the casing of the device by pushing
the fastening on top of the device to remove
the front panel from the back cover.
Product description
The Vibration Sensor detects and reports
vibration. Attached to windows, the Vibration
Sensor can detect breaking glass and warn
about break-ins. It can be mounted underneath
beds to monitor patients* sleep or on piping to
identify blockages and other abnormalities.
Vibration Sensor
2. Insert the enclosed batteries into the device,
respecting the polarities.
3. Close the casing.
4. The Vibration Sensor will now start
searching (up to 15 minutes) for a Zigbee
network to join.
5. Make sure that the Zigbee network is open
for joining devices and will accept the
Vibration Sensor.
6. While the Vibration Sensor is searching for
a Zigbee network to join, the red LED is
ashing.
Precautions 7. When the red LED stops ashing, the
Vibration Sensor has successfully joined the
Zigbee network.
INSTALLATION MANUAL
Version 1.2
Resetting
Resetting is needed if you want to connect your
Vibration Sensor to another gateway or if you
need to perform a factory reset to eliminate
abnormal behavior.
The reset button is marked with the small ring
on the front of the sensor.
STEPS FOR RESETTING
1. Press and hold down the reset button until
the LED rst ashes once, then two times in
a row, and nally numerous times in a row.
2. Release the button while the LED is ashing
numerous times in a row.
Modes
SEARCHING GATEWAY MODE
Red ashes every second for a longer period,
means that the device is searching for a
gateway.
LOST CONNECTION MODE
When the red LED ashes 3 times, it means that
the device has failed to connect to a gateway.
LOW-BATTERY MODE
Two consecutive red LED ashes every 60
seconds, means that the battery should be
replaced.
Fault nding
In case of a bad or weak signal, change
the location of the Vibration Sensor.
Otherwise you can relocate your gateway
or strengthen the signal with a smart plug.
If the search for a gateway has timed out, a
short press on the button will restart it.
Battery replacement
CAUTION:
Do not attempt to recharge or open the
batteries.
Risk of explosion if batteries are replaced by
an incorrect type.
Dispose of a battery into re or a hot oven, or
mechanically crushing or cutting of a battery
can result in an explosion
Leaving a battery in an extremely high
temperature surrounding environment can
result in an explosion or the leakage of
ammable liquid or gas.
A battery subjected to extremely low air
pressure may result in an explosion or the
leakage of ammable liquid or gas
Maximum operation temperature is 50°C /
122°F
If you experience leakage from the batteries,
immediately wash your hands and/or any
aected area of your body thoroughly!
CAUTION: When removing cover for battery
change - Electrostatic Discharge (ESD) can
harm electronic components inside.
1. Open the casing of the device by pushing
the fastening on top of the device to remove
the front panel from the back cover.
2. Replace the batteries respecting the
polarities. The Vibration Sensor uses 2xAAA
batteries.
3. Close the casing.
4. Test the Vibration Sensor.
Other information
Note local regulations about information to
your insurance company regarding installed
Vibration Sensors.
Disclaimers
CAUTION:
Choking hazard! Keep away from children.
Contains small parts.
Please follow the guidelines thoroughly. The
Vibration Sensor is a preventive, informing
device, not a guarantee or insurance that
sucient warning or protection will be
provided, or that no property damage,
theft, injury, or any similar situation will
take place. Develco Products cannot be
held responsible in case any of the above-
mentioned situations occur.
3. After you release the button, the LED shows
one long ash, and the reset is completed.
MOUNTING EXAMPLE 3: PIPINGS
1. Clean the surface before mounting.
2. The Vibration Sensor should be mounted
on the pipe using the double stick tape,
already applied on the back of the sensor.
Press rmly to secure sensor.
MOUNTING EXAMPLE 2: BED
1. Clean the surface before mounting.
2. The Vibration Sensor should be mounted
on the frame underneath the bed using the
double stick tape, already applied on the
back of the sensor. Press rmly to secure
sensor.
c.
H6500187 Vibration Sensor installation manual v1.2.indd 1H6500187 Vibration Sensor installation manual v1.2.indd 1 10/7/2021 12:11:50 PM10/7/2021 12:11:50 PM
Other certications
Zigbee 3.0 certied
Develco Products assumes no responsibility for
any errors, which may appear in this manual.
Furthermore, Develco Products reserves the
right to alter the hardware, software, and/
or specications detailed herein at any time
without notice, and Develco Products does
not make any commitment to update the
information contained herein. All the trademarks
listed herein are owned by their respective
owners.
Distributed by Develco Products A/S
Tangen 6
8200 Aarhus
Denmark
All rights reserved.
IN ACCORDANCE WITH THE DIRECTIVES
Radio Equipment Directive (RED) 2014/53/
EU
RoHS Directive 2015/863/EU amending
2011/65/EU
REACH 1907/2006/EU + 2016/1688
CE certication
The CE mark axed to this product conrms
its compliance with the European Directives
which apply to the product and, in particular, its
compliance with the harmonized standards and
specications.
FCC statement
Changes or modications to the equipment not
expressly approved by the party responsible for
compliance could void the user’s authority to
operate the equipment.
NOTE: This equipment has been tested and
found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to
provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses and can
radiate radio frequency energy and, if not
installed and used in accordance with the
instructions, may cause harmful interference
to radio communications. However, there is no
guarantee that interference will not occur in a
particular installation.
If this equipment does cause harmful
interference to radio or television reception,
which can be determined by turning the
equipment o and on, the user is encouraged
to try to correct the interference by one or more
of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the
equipment and receiver.
Connect the equipment into an outlet on
a circuit dierent from that to which the
receiver is connected.
Consult the dealer or an experienced radio/
TV technician for help.
This device complies with FCC RF radiation
exposure limits set forth for an uncontrolled
environment. The antenna used for this
transmitter must be installed to provide a
separation distance of at least 20 cm from
all persons and must not be co-located or
operating in conjunction with any other antenna
or transmitter.
FCC statement
Français
L’émetteur/récepteur exempt de licence
contenu dans le présent appareil est
conforme aux CNR d’Innovation, Sciences
et Développement économique Canada
applicables aux appareils radio exempts de
licence. L’exploitation est autorisée aux deux
conditions suivantes :
1. L’appareil ne doit pas produire de brouillage;
2. L’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage
est susceptible d’en compromettre le
fonctionnement.
Cet équipement est conforme aux limites
d’exposition aux radiations IC CNR-102 établies
pour un environnement non contrôlé. Cet
équipement doit être installé et utilisé avec une
distance minimale de 20 cm entre le radiateur
et votre corps.
English
This device contains licence-exempt
transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic
Development Canada’s licence-exempt RSS(s).
Operation is subject to the following two
conditions:
1. This device may not cause interference.
2. This device must accept any interference,
including interference that may cause
undesired operation of the device.
This equipment complies with IC RSS-102
radiation exposure limits set forth for an
uncontrolled environment. This equipment
should be installed and operated with minimum
distance 20 cm between the radiator and your
body.
IC statement
ISED statement
Innovation, Science and Economic
Development Canada ICES-003 Compliance
Label: CAN ICES-3 (B)/NMB-3(B).
ISED statement
This device complies with part 15 of the FCC
Rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful
interference, and
2. this device must accept any interference
received, including interference that may
cause undesired operation.
Disposal
Dispose the product and battery properly at the
end of life. This is electronic waste which should
be recycled.
H6500187 Vibration Sensor installation manual v1.2.indd 2H6500187 Vibration Sensor installation manual v1.2.indd 2 10/7/2021 12:11:50 PM10/7/2021 12:11:50 PM
  • Page 1 1
  • Page 2 2

Develco WISZB-137 Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues