Heat & Glo Tiara Petite-B TiaraP Install Manual

Catégorie
Cheminées
Taper
Install Manual
WARNING
DO NOT DISCARD THIS MANUAL
CAUTION
• Important operating and
maintenance instructions
included.
Leave this manual with
party responsible for use
and operation.
• Read, understand and
follow these instructions
for safe installation and
operation.
Do not store or use gasoline or other À am-
mable vapors and liquids in the vicinity of this
or any other appliance.
What to do if you smell gas
- Do not try to light any appliance.
Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from a
neighbors phone. Follow the gas suppliers
instructions.
- If you cannot reach your gas supplier, call
the ¿ re department.
Installation and service must be performed
by a quali¿ ed installer, service agency, or the
gas supplier.
WARNING: If the information in these
instructions is not followed exactly, a ¿ re
or explosion may result causing property
damage, personal injury, or death.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions and
the manufactured home construction and safety standard, Title
24 CFR, Part 3280 or Standard for Installation in Mobile Homes,
CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indicated on
the rating plate.
Installation and service of this appliance should be
performed by quali¿ ed personnel. Hearth & Home
Technologies suggests NFI certi¿ ed or factory-trained
professionals, or technicians supervised by an NFI
certi¿ ed professional.
DO NOT
DISCARD
TIARA PETITE B
DIRECT VENT ROOM HEATER
Owners Manual
Installation and Operation
TIARAP-BK
TIARAP-BR
TIARAP-CES
Model:
O-T
O-T L
Tested and
Listed by
Portland
Oregon USA
OMNI-Test Laboratories, Inc.
CUS
In the Commonwealth of Massachusetts:
installation must be performed by a licensed plumber or
gas ¿ tter.
See Table of Contents for additional Commonwealth of
Massachusetts requirements.
HOT SURFACES!
Glass and other surfaces are
hot during operation AND cool
down.
Hot glass will cause burns.
Do not touch glass until it is cooled
• NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in the same room as
appliance
Alert children and adults to hazards of high temperatures
High temperatures may ignite clothing or other
À ammable materials.
Keep clothing, furniture, draperies and other combustibles
away.
Heat & Glo • Tiara Petite B • 7026-101 Rev. Q • 10/13
2
Read this manual before installing or operating this appliance.
Please retain this owner's manual for future reference.
Congratulations
Congratulations on selecting a Heat & Glo gas appliance - an
elegant and clean alternative to wood burning appliances.
The Heat & Glo gas appliance you have selected is designed
to provide the utmost in safety, reliability, and efficiency.
As the owner of a new appliance, you'll want to read and
carefully follow all of the instructions contained in this
Owner's Manual. Pay special attention to all Cautions and
Warnings.
This Owner's Manual should be retained for future reference.
We suggest that you keep it with your other important
documents and product manuals.
Your new Heat & Glo gas appliance will give you years of
durable use and trouble-free enjoyment. Welcome to the
Heat & Glo family of gas appliance products!
SAMPLE OF RATINGS LABEL
LOCATION: Hang tag attached to rear of appliance.
Serial No.
Model Name
Test Lab & Report No.
Manufactured Date
MINIMUM CLEARANCES TO COMBUSTIBLES / ESPACE MINIMUM AUX COMBUSTIBLES
Minimum clearances required from combustible construction for all appliance surfaces. / Espaces minimum exigés de la construction combustible aux surfaces de l’appareil.
A. Side of stove top to side wall 6" (15cm) D
u coté du poêle au coté du mur
B. Rear of stove to back wall 2" (5cm)
Le contrôle arrière au mur arrière
C. Corner of stove top to side wall-Left 2" (5cm)
Du coin arrière du poêle au mur de coté gauche
C. Corner of stove top to side wall-Right
2" (5cm) Du coin du dessus du po
êle au mur de coté droit (acces a la valve)
D. Minimum Alcove Height 43" (109cm) Ha
uteur minimum du plancher au plafond
E. Maximum Alcove Depth 36" (91cm) P
rofondeur maximum de l'alcove
F. Minimum Alcove Width 30" (76cm)
Largeur minimum de l'alcove
G. Mantle Clearance from stove top 19-1/2" (50cm) Espace libre du po
êle au manteau
H. Top of Stove to Alcove Ceiling 20-1/4" (51cm) Dessus de fourneau au plafond de chambrette
Date of Manufacture / Date du Manufacturier
2008 2009 2010 Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L’ÉTIQUETTE Made in U.S.A. / Fait Aux États-Unis
HEARTH: A non-combustible hearth pad is not required. However, the floor beneath the stove must be stable, level, and strong enough to support the stove without a tipping hazard.
CHEMINÉE: Un coussinet non-combustible de cheminée n’est pas exigé. Cependant, le plancher en dessous du poêle doit être droit, à niveau et assez fort pour supporter le poêle sans le hasard de basculer.
This appliance equipped for altitudes 0-2000’ (0-610m) in USA; and in Canada for altitudes of 0-4500’ (0-1370m). In USA for Altitudes above 2000’, the vent configuration, orifice or combination
of both may need to be changed. See Owner’s Manual for information on making these changes. This appliance must be installed in accordance with local codes, if any (and Commonwealth
of Massachusetts approved); if none, follow ANSI Z223.1 in USA, CAN 1-B149 in Canada. Install and use only in accordance with manufacturer’s installation and operating instructions.
NOTE:
Have the gas supply line installed in accordance with local building codes by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts, installation must
be performed by a licensed plumber or gas fitter.) /
Cet appareil est équipé pour les altitudes de 0-2000’ (0-610m) aux États-Unis; et au Canada pour les altitudes de 0-4500’ (0-1370m). Pour les
altitudes au dessus de 2000’ aux États-Unis, la configuration du ventilateur, son orifice ou les deux peuvent possiblement avoir à être changé. Voyez le manuel du propriétaire pour les
informations sur ces changements. Cet appareil doit être installé en accord avec les codes locaux, s’il-y-a lieu (et approuvé par dans la République de Massachusetts); sinon lisez ANSI
Z223.1/CAN 1-B149. Installez et utilisez en accords avec les instructions d’installation et d’opération du manufacturier. REMARQUE: Le conduit gaz doit être installé conformément aux codes
de construction locaux. L'installation doit être effectuée par un technicien qualifeé et/ou muni d'une licence de manière à respecter les règlements municipaux. (Dans la République de Massachusetts,
l'installation doit être effectuée par un plombier ou un installateur d'appareils à gaz agrée.)
0-2000 FT’ 0-2000FT
Input Rate on “HI” (BTU/Hr) 17,000 17,000 Puissance Évaluée à “HI” (BTU/Hr)
Input Rate on “LO” (BTU/Hr) 12,000 13,000 Puissance Évaluée à “LO” (BTU/Hr)
Maximum Output (BTU/Hr)** 14,500 13,500 Puissance Maximum (BTU/Hr**
Main Burner Orifice 49 56 Orifice du Brûleur Principal
Minimum Inlet Pressure
(Inches W.C.)
4.5” 11” Pression Minimum de la Valve (pouces W.C.)
Maximum Inlet Pressure
(Inches W.C.)
7.0” 14” Pression Maximum de la Valve (pouces W.C.)
M
anifold Pressure on
“HI”
(Inches W.C.)
3.5” 10” Pression du Collecteur d’ Échappement à “HI” (pouces W.C.)
**Max Venting, Blower On **Ventilation Maximum, Ventilateur Allumé
For use with Propane
Usage Au Gaz Propane
APPROVED FOR CANADA AND USA TO: ANSI Z21.88b-2003 / CSA 2.33b-2003 Vented Gas Fireplace Heaters, and applicable sections of UL307b Gas Burning Heating Appliances for Manufactured Homes and Recreational
Vehicles, CAN/CGA 2.17-M91 Gas Fired Appliances for use at High Altitudes. This appliance is manufactured for operation with Natural Gas. For conversion to propane Manufacturer's instructions must be used. This
appliance may be installed in a bedroom or bedsitting room; in Canada remote thermostat installation is required.
APPROUVÉ-POUR LE CANADA ET LES ÉTATS-UNIS: ANSI-Z21.88b-2003 / CSA 2.33b-2003 Fournaises au Gaz avec Ventilation, et les sections applicable de UL 307b Appareils de Chauffage Au Gaz our les Maisons Mobiles et les
Vehicules Motoriss, CAN/CGA 2.17-M91 Gas Fired Appliances for use at High Altitudes. Cet appareil est manufactur pour l'operation avec le Gaz Naturel. Pour une conversion au gaz propane les pices du Manufacturier et ses
instructions doivent tre utilises. Cet appareil peut tre utilis dans une chambre à coucher ou salle de sjour, au Canada, l'installation d'un thermostat à distance est exige.
FAN TYPE VENTED CIRCULATOR / VENTILATEUR CIRCULATOIRE
Blower Electrical Rating / Evaluation du Ventilateur
115 V., .55 Amps, 60 Hz, 150 Watts
Blower is Optional. Order Part #844-9370
Route power cord away from unit. Do not route
power cord under or over stove./
Éloignez le fil électrique
de l'appareil. Ne pas faire passer le fil électrique au dessus
ou en dessous de l'appareil.
P.4.1-02 Canada Minimum pipe (P.4.1-02 Le Canada tuyau minimum) 67.38% NG / 69.52% LP
A
A
C
C
Left
A
B
E
A
"A" measurement is from
stove top, not side
D
G
F
H
Right
For use with Natural Gas
Usage Au Gaz Naturel
7026-102
SAMPLE
SAMPLE
VENTED GAS FIREPLACE HEATER
NOT FOR USE WITH SOLID FUEL
Serial No / Numéro du
Report No. / Rapport Numéro
061-S-47b-5 FOURNAISE AU GAZ AVEC VENTILATION
NE PAS UTILISER AVEC LE COMBUSTIBLE SOLIDE
MODEL / MODÈLE: TIARA PETITE (B)
A division of Hearth & Home Technologies Inc.
20802 Kensington Boulevard
Lakeville, MN 55044
007
O-T
O-T L
Tested and
Listed by
Portland
Oregon USA
OMNI-Test Laboratories, Inc.
CUS
Barcode
Heat & Glo • Tiara Petite B • 7026-101 Rev. Q • 10/13
3
- TABLE OF CONTENTS -
Section 1: Listing and Code Approvals
A. Appliance Certi¿ cations ......................4
B. Glass Speci¿ cations ............................4
C. Speci¿ cations ......................................4
D. High Altitude Installations ....................4
E. Non-Combustible Materials .................4
F. Combustible Materials ........................4
G. Requirements for the
Commonwealth of Massachusetts ......5
Section 2: Getting Started
A. Design & Installation
Considerations ....................................6
B. Tools and Supplies Needed................6
C. Inspect Appliance & Components .......6
Section 3: Appliance Location & Clearances
A. Selecting Appliance Location..............7
B. Clearances to Combustibles ...............7
Section 4: Termination Locations
A. Vent Termination Minimum
Clearances..........................................8
Section 5: Vent Information
A. Venting Components ..........................10
B. Use of Elbows .....................................10
C. Measuring Standards ..........................10
D. How to Use the Vent Graph ................11
E. Venting Guidelines ..............................11
F. Horizontal Termination ........................12
G. Vertical Termination ............................15
H. Slim Line Wall Thimble .......................23
Section 6: Gas Information
A. Fuel Conversions ................................25
B. Gas Pressures ....................................27
C. Gas Connection.. ................................27
Section 7: Electrical Information
A. Recommendation for Wire ..................29
B. Connecting to the Appliance ...............29
C. Standing Pilot Ignition System
Wiring ..................................................29
D. Ignition Module Access and
Battery Replacement ..........................30
Section 8: Appliance Setup
A. Remove Shipping Materials ................31
B. Leg Leveling System ...........................31
C. Flue Restrictor Installation ..................31
D. Intake Damper Operation ....................32
E. Intake Air Shutter Adjustment .............32
F. Positioning the Logs ............................32
G. Mineral Wool .......................................33
H. Accessories .........................................33
I. Blower Installation ...............................34
J. Glass Replacement .............................36
Section 9: Operating Instructions
A. Before Lighting Appliance ...................37
B. Controls ...............................................37
C. Lighting Appliance ...............................38
D. After Appliance is Lit ...........................39
E. Frequently Asked Questions ...............39
Section 10: Troubleshooting ...............................40
Section 11: Maintaining & Servicing Appliance
A. Maintenance Tasks .............................42
Section 12: Reference Materials
A. Appliance Dimension Diagram ...........44
B. Vent Components Diagram ................45
C. Vent Components List ........................46
D. Service Parts List ................................48
E. Limited Lifetime Warranty ...................52
F. Contact Information ............................54
Î= Contains updated information.
Heat & Glo • Tiara Petite B • 7026-101 Rev. Q • 10/13
Î
Î
Î
Î
4Heat & Glo • Tiara Petite B • 7026-101 Rev. Q • 10/13
1Listing and Code Approvals
The product is listed to ANSI standards for “Vented Gas
Appliance Heaters” and applicable sections of “Gas Burning
Heating Appliances for Manufactured Homes and Recre-
ational Vehicles” and "Gas Fired Appliances for use at High
Altitudes".
A. Appliance Certi¿ cation
B. Glass Speci¿ cations
NOTE: This installation must conform with local codes. In the
absence of local codes you must comply with the National
Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A.
and the CAN/CGA B149 Installation Codes in Canada.
D. High Altitude Installations
Omni-Test Laboratories, Inc. listed gas appliances are tested
and approved without requiring changes for elevations from
0 to 2000 feet in the U.S.A. and 0 to 4500 feet in Canada.
When installing this appliance at an elevation above 2000
feet, it may be necessary to decrease the input rating by
changing the existing burner ori¿ ce to a smaller size. Input
rate should be reduced by 4% for each 1000 feet above a
2000 foot elevation in the U.S.A. If the heating value of the
gas has been reduced, these rules do not apply. To identify
the proper ori¿ ce size, check with the local gas utility.
If installing this appliance at an elevation above 4500 feet (in
Canada), check with local authorities.
C. Speci¿ cations
This appliance is equipped with 5mm ceramic glass behind
the curved glass. Replace glass only with 5mm ceramic
glass. Please contact your dealer for replacement glass.
WARNING
Do NOT use this appliance if any part has been under water.
Immediately call a quali¿ ed service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
Manufactured Home or Mobile Home installation may occur
only after the home is site located and must conform with
the Manufactured Home Construction and Safety Standard,
Title 24 CFR, Part 3280, or, when such a standard is
not applicable, the Standard for Manufactured Home
Installations, ANSI/NCSBCS A225.1, or Standard for Gas
Equipped Recreational Vehicles and Mobile Housing, CSA
Z240.4.
When installed, the appliance must be electrically grounded
in accordance with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70, or
the Canadian Electrical Code, CSA C22.1.
*Maximum Vent Blower On
**Canada Only
MODEL Tiara Petite B
LABORATORY OMNI-Test Laboratories, Inc.
061-S-47b-5
TYPE Vented Gas Fireplace Heater
STANDARD ANSI Z21.88b-2003 ʘ CSA 2.33b-2003ʘ
UL307b ʘ CAN/CBA 2.17-M91
Model
(US or Canada)
Maxi-
mum
Input
BTU
Mini-
mum
Input
BTU
Ori¿ ce
Size
(DMS)
*Steady
State
Ef¿ -
ciency
%
**P.4
%
Tiara Petite B
(NG)
17,000 12,000 49 73.93 57.30
Tiara Petite B
(LP)
17,000 13,000 56 78.19 63.22
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750°C, shall be considered non-
combustible materials.
Materials made of or surfaced with wood, compressed
paper, plant fibers, plastics, or other materials that can ignite
and burn, whether flame proofed or not, or whether plastered
or unplastered shall be considered combustible materials.
E. Non-Combustible Materials
F. Combustible Materials
5Heat & Glo • Tiara Petite B • 7026-101 Rev. Q • 10/13
NOTE: The following requirements reference various
Massachusetts and national codes not contained in this
document.
For all side wall horizontally vented gas fueled equipment
installed in every dwelling, building or structure used in whole
or in part for residential purposes, including those owned or
operated by the Commonwealth and where the side wall
exhaust vent termination is less than seven (7) feet above
¿ nished grade in the area of the venting, including but not
limited to decks and porches, the following requirements
shall be satis¿ ed:
Installation of Carbon Monoxide Detectors
At the time of installation of the side wall horizontal vented
gas fueled equipment, the installing plumber or gas ¿ tter shall
observe that a hard wired carbon monoxide detector with an
alarm and battery back-up is installed on the À oor level where
the gas equipment is to be installed. In addition, the installing
plumber or gas ¿ tter shall observe that a battery operated
or hard wired carbon monoxide detector with an alarm is
installed on each additional level of the dwelling, building or
structure served by the side wall horizontal vented gas fueled
equipment. It shall be the responsibility of the property owner
to secure the services of quali¿ ed licensed professionals for
the installation of hard wired carbon monoxide detectors.
In the event that the side wall horizontally vented gas fueled
equipment is installed in a crawl space or an attic, the hard
wired carbon monoxide detector with alarm and battery back-
up may be installed on the next adjacent À oor level.
In the event that the requirements of this subdivision can not
be met at the time of completion of installation, the owner shall
have a period of thirty (30) days to comply with the above
requirements; provided, however, that during said thirty (30)
day period, a battery operated carbon monoxide detector with
an alarm shall be installed.
Approved Carbon Monoxide Detectors
Each carbon monoxide detector as required in accordance
with the above provisions shall comply with NFPA 720 and
be ANSI/UL 2034 listed and IAS certi¿ ed.
Signage
A metal or plastic identi¿ cation plate shall be permanently
mounted to the exterior of the building at a minimum height
of eight (8) feet above grade directly in line with the exhaust
vent terminal for the horizontally vented gas fueled heating
appliance or equipment. The sign shall read, in print size no
less than one-half (1/2) inch in size, “GAS VENT DIRECTLY
BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS.”
G. Requirements for the Commonwealth of
Massachusetts
Inspection
The state or local gas inspector of the side wall horizontally
vented gas fueled equipment shall not approve the installa-
tion unless, upon inspection, the inspector observes carbon
monoxide detectors and signage installed in accordance with
the provisions of 248 CMR 5.08(2)(a) 1 through 4.
Exemptions
The following equipment is exempt from 248 CMR 5.08(2)
(a) 1 through 4:
The equipment listed in Chapter 10 entitled “Equipment
Not Required To Be Vented” in the most current edition of
NFPA 54 as adopted by the Board; and
Product Approved side wall horizontally vented gas fueled
equipment installed in a room or structure separated from
the dwelling, building or structure used in whole or in part
for residential purposes.
MANUFACTURER REQUIREMENTS
Gas Equipment Venting System Provided
When the manufacturer of Product Approved side wall
horizontally vented gas fueled equipment provides a vent-
ing system design or venting system components with the
equipment, the instructions provided by the manufacturer for
installation of the equipment and the venting system shall
include:
Detailed instructions for the installation of the venting sys-
tem design or the venting system components; and
A complete parts list for the venting system design or
venting system.
Gas Equipment Venting System NOT Provided
When the manufacturer of a Product Approved side wall hor-
izontally vented gas fueled equipment does not provide the
parts for venting the À ue gases, but identi¿ es “special vent-
ing systems”, the following requirements shall be satis¿ ed by
the manufacturer:
The referenced “special venting system” instructions shall
be included with the appliance or equipment installation
instructions; and
The “special venting system” shall be Product Approved
by the Board, and the instructions for that system shall
include a parts list and detailed installation instructions.
A copy of all installation instructions for all Product Approved
side wall horizontally vented gas fueled equipment, all vent-
ing instructions, all parts lists for venting instructions, and/
or all venting design instructions shall remain with the appli-
ance or equipment at the completion of the installation.
See Gas Connection section for additional Common-
wealth of Massachusetts requirements.
6Heat & Glo • Tiara Petite B • 7026-101 Rev. Q • 10/13
2Getting Started
Check building codes prior to installation.
Installation MUST comply with local, regional, state
and national codes and regulations.
Consult local building, ¿ re of¿ cials or authorities having
jurisdiction about restrictions, installation inspection,
and permits.
CAUTION
A
. Design & Installation Considerations
B. Tools and Supplies Needed
C. Inspect Appliance & Components
Heat & Glo direct vent gas appliances are designed to oper-
ate with all combustion air drawn from outside of the building
and all exhaust gases expelled to the outside. No additional
air source is required.
When planning an installation, it is necessary to determine
the following information before installing:
Where the appliance is to be installed.
The vent system con¿ guration to be used.
Gas supply piping.
Electrical wiring.
Whether optional accessories - devices such as a blower,
thermostat or remote control - are desired.
Before beginning the installation be sure that the following
tools and building supplies are available. Note: Not all
tools will apply to every installation.
Carefully remove the appliance and components from
the packaging.
Remove cast door and glass door, and set aside on pro-
tective surface.
Remove log set and component pack from ¿ rebox.
Report to your dealer any parts damaged in shipment,
particularly the condition of the glass.
Read all of the instructions before starting the instal-
lation. Follow these instructions carefully during the
installation to ensure maximum safety and bene¿ t.
Reciprocating saw Variable Speed Drill/Driver
Pliers Wrench Set
Hammer Framing Square
Phillips Screwdriver Framing Material
Flat Blade Screwdriver Voltmeter
Plumb Line Gloves
Level Safety Glasses
Manometer Tape Measure
Non-corrosive Leak Check Solution or combustible gas
detector
Caulking material (300ºF minimum continuous exposure
rating)
Keep appliance dry.
Mold or rust may cause odors.
Water may damage controls.
WARNING
Installation and use of any damaged appliance or vent
system component.
• Modi¿ cation of the appliance or vent system.
Installation other than as instructed by Hearth & Home
Technologies.
Improper positioning of the gas logs or the glass door.
Installation and/or use of any component part not approved
by Hearth & Home Technologies.
Any such action may cause a ¿ re hazard.
WARNING
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be
voided by, the following actions:
Inspect appliance and components for
damage. Damaged parts may impair safe
operation.
WARNING
Do NOT install damaged components.
Do NOT install incomplete components.
Do NOT install substitute components.
Report damaged parts to dealer.
7Heat & Glo • Tiara Petite B • 7026-101 Rev. Q • 10/13
3Appliance Location and Clearances
A. Selecting Appliance Location
NOTE:
· Illustrations reÀ ect typical installations and are FOR
DESIGN PURPOSES ONLY.
· Illustrations/diagrams are not drawn to scale.
· Actual installation may vary due to individual design
preference.
When selecting a location for your appliance it is important
to consider the required clearances to wall (see Figure 3.1).
Figure 3.1
B. Clearances to Combustibles
Model AB C DE F G H
Tiara
Petite B
Inches 6 2 2 43 36 30 20-1/4 19-1/2
Millimeters 152 51 51 1092 914 762 527 495
A
B
F
E
A
"A" measurement is from
stove top, not side
C
C
A
G-Alcove
A
D
H
WARNING
Fire Risk
Provide adequate clearance:
Around air openings
• To combustibles
For service access
Locate appliance away from traf¿ c areas.
NOTE: For actual appliance dimensions refer to
Section 12.
Fire Risk.
Locate and install appliance to all
clearance speci¿ cations in manual.
WARNING
NOTE: Flooring beneath appliance may reach 90 degrees
plus room ambient temperature. Check with flooring
manufacturer for maximum temperature allowed on flooring
surfaces.
It is permissable to place the appliance on carpet.
CAUTION
Some carpet materials may be sensitive to radiant heat from the
appliance causing discoloration or odor.
Fire Risk.
Odor Risk.
Tipping Risk
Install appliance on a stable, level platform/
À oor strong enough to support appliance
without tipping.
• USE wood À ooring, ceramic tile, brick hearth
or high pressure laminate À ooring applied
directly over the sub-À ooring material.
WARNING
8Heat & Glo • Tiara Petite B • 7026-101 Rev. Q • 10/13
4Termination Locations
A. Vent Termination Minimum Clearances
Figure 4.2 Multiple Vertical Temination
Figure 4.1 Termination Clearances
Figure 4.3 speci¿ es minimum vent heights for various
pitched roofs.
Figure 4.3 Minimum Height from Roof to Lowest Discharge
HORIZONTAL
OVERHANG
VERTICAL
WALL
GAS DIRECT VENT
TERMINATION CAP
12
X
ROOF PITCH
IS X/ 12
LOWEST
DISCHARGE
OPENING
2 FT.
MIN.
20 INCHES MIN.
H (MIN.) - MINIMUM HEIGHT FROM ROOF
TO LOWEST DISCHARGE OPENING
Roof Pitch H (Min.) Ft.
Flat to 6/12 .........................................................1.0*
Over 6/12 to 7/12........................................................1.25*
Over 7/12 to 8/12 ............................................... 1.5*
Over 8/12 to 9/12 ............................................... 2.0*
Over 9/12 to 10/12 ............................................. 2.5*
Over 10/12 to 11/12 ........................................... 3.25
Over 11/12 to 12/12 ........................................... 4.0
Over 12/12 to 14/12 ........................................... 5.0
Over 14/12 to 16/12 ........................................... 6.0
Over 16/12 to 18/12 ........................................... 7.0
Over 18/12 to 20/12 ........................................... 7.5
Over 20/12 to 21/12 ........................................... 8.0
* 3 foot minimum in snow regions
Measure vertical clearances from this surface.
Measure horizontal clearances from this surface.
(See Figure 4.4 for speci¿ c clearances.)
Opening
Fire Risk.
Explosion Risk.
Maintain vent clearance to combustibles
as speci¿ ed.
WARNING
Do not pack air space with insulation or
other materials.
Failure to keep insulation or other materials
away from vent pipe may cause ¿ re.
Gas, Wood or Fuel Oil
Termination Cap
B
Gas
Termination
Cap **
A *
*If using decorative cap cover(s), this distance may need to be
increased. Refer to the installation instructions supplied with the
decorative cap cover.
**
AB
6 in. (minimum) up to 20 in.
152 mm/508 mm
18 in. minimum
457 mm
20 in. and over 0 in. minimum
In a staggered installation with both gas and wood or fuel oil
terminations, the wood or fuel oil termination cap must be
higher than the gas termination cap.
9Heat & Glo • Tiara Petite B • 7026-101 Rev. Q • 10/13
CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING,
IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED.
Figure 4.4
V
= VENT TERMINAL
X
= AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED
A = 12 inches ............. clearances above grade, veran-
da, porch, deck or balcony
B = 12 inches ............ clearances to window or door
that may be opened, or to per-
manently closed window. (Glass)
D* = 18 inches ............. vertical clearance to unventilat-
ed soffit or to ventilated soffit lo-
cated above the terminal
*30 inches ............ for vinyl clad soffits and below
electrical service
F = 9 inches .............. clearance to outside corner
G = 6 inches ............... clearance to inside corner
H = 3 ft. (Canada) ...... not to be installed above a gas
meter/regulatorassemblywithin 3
feet (90cm) horizontally from the
center-line of the regulator
I= 3 ft. ....................... clearance to gas service regula-
tor vent outlet
J = 9 inches (U.S.A.)
12 inches (Canada)clearance to non-mechanical air
supply inlet to building or the
combustion air inlet to any other
appliance
K = 3 ft. (U.S.A.)
6 ft. (Canada) ......... clearance to a mechanical
(powered) air supply inlet
L** = 7 ft. ......................... clearance above paved
sidewalkor a paved driveway
located on public property
M*** = 18 inches .............. clearance under veranda ,
porch, deck, balcony or over-
hang
42 inches .............. vinyl
** a vent shall not terminate directly above a sidewalk or paved
driveway which is located between two single family dwellings and
serves both dwellings.
*** only permitted if veranda, porch, deck or balcony is fully open on
a minimum of 2 sides beneath the floor, or meets Note 2.
(See Note 1)
(See Note 1)
S = 6 inches ................. clearance from sides of
electrical service
T = 12 inches ................ clearance above electrical
service
(See Note 3)
(See Note 3)
___________________________________________________________________
_
___________________________________________________________________
_
___________________________________________________________________
_
_
Q
MIN
R
MAX
1cap 3feet 2xQ
ACTUA L
2 caps 6 feet 1 x Q
ACTUA L
3 caps 9 feet 2/3 x Q
ACTUA L
4caps 12feet 1/2xQ
ACTUA L
QMIN = # termination caps x 3 RMAX = (2 / # termination caps) xQACTUAL
N = 6 inches ................. non-vinyl sidewalls
12 inches ............... vinyl sidewalls
P=8ft.
Alcove Applications
NOTE 1: On private property where termination is less than 7 feet above
a sidewalk, driveway, deck, porch, veranda or balcony, use of a listed
cap is suggested. (See vents components pages.)
NOTE 2: Termination in an alcove space (spaces only open on one side
and
without
an overhang) are permitted with the dimensions specified for
vinyl or non-vinyl siding and soffits. 1. There must be at least 3 feet
minimum between termination caps. 2. All mechanical air intakes within
10 feet of a termination cap must be a minimum of 3 feet below the
termination cap. 3. All gravity air intakes within 3 feet of a termination cap
must be a minimum of 1 foot below the termination cap.
NOTE 3: Location of the vent termination must not interfere with access
NOTE: Local codes or regulations may require different
clearances.
NOTE: Termination caps may be hot. Consider their proximity to
doors or other traffic areas.
WARNING: In the U.S.: Vent system termination is NOT permitted
in screened porches. You must follow side wall, overhang and
ground clearances as slated in the instructions.
In Canada: Vent system termination is NOT permitted in screened
porches. Vent system termination is permitted in porch areas with
two or more sides open. You must follow side wall, overhang and
ground clearances as stated in the instructions.
Quadra-Fire assumes no responsibility for the improper perfor-
mance of the appliance when the venting system does not meet
these requirements.
(See Note 2)
Electrical
Service
V
S
VS
V
T
D*
V
D
E
B
L
v
v
v
v
v
v
v
v
B
B
AH
M
X
J or K
I
A
G
F
U.S.
(3 FT)
B
M
N
P
R
Q
10 Heat & Glo • Tiara Petite B • 7026-101 Rev. Q • 10/13
5Vent Information
A. Venting Components B. Use of Elbows
In order to comply with applicable codes and product
warranties, use only following venting components:
Hearth & Home Technologies (HHT)
Simpson Dura-Vent
Selkirk Direct-Temp
Amerivent Direct
Security Secure Vent
DO NOT USE FIELD-FABRICATED VENTING
COMPONENTS. Refer to the venting manufacturer’s
instructions.
This product is approved to be vented either horizontally,
through the side wall or vertically through the roof. You may
vent through a Class A or masonry chimney if an approved
adapter is used.
This appliance is a direct vent heater. All combustion air must
come directly from the outside of the building. The vent pipe
for this unit consists of an inner and an outer pipe. The inner
pipe carries the appliance exhaust out of the system, and the
outer pipe brings fresh combustion air into the appliance.
Fire Hazard.
Explosion Risk.
Asphyxiation Risk.
Do NOT connect this gas appliance to a chimney
À ue serving a separate solid-fuel or gas burning
appliance.
Vent this appliance directly outside.
Use separate vent system for this appliance.
May impair safe operation of this appliance or
other appliances connected to the À ue.
WARNING
Diagonal runs have both vertical and horizontal vent aspects
when calculating the effects. Use the rise for the vertical
aspect and the run for the horizontal aspect. (See Figure 5.1.)
Two 45° elbows may be used in place of one 90° elbow. On
45° runs, one foot of diagonal is equal to 8-1/2 in. (216mm)
horizontal run and 8-1/2 in. (216mm) vertical run. A length of
straight pipe is allowed between two elbows. (See Figure 5.1.)
Vertical
Horizontal
12 in.
8-1/2 in.
8-1/2 in.
Vertical and horizontal measurements were made using the
following standards.
C. Measuring Standards
CAUTION
ALL vent con¿ guration speci¿ cations MUST be followed.
This product is tested and listed to these
speci¿ cations.
Appliance performance will suffer if speci¿ cations are
not followed.
Figure 5.1
Pipe measurements are from center line to center line.
Horizontal terminations are measured to the outside of
the mounting surface (À ange of termination cap). See
Figure 4.1 on page 8.
Vertical terminations are measured to the top of the last
pipe before termination cap.
Horizontal pipe installed level with 1/4 in. rise.
A round support box/wall thimble or heat shield is
required when the venting passes through a combus-
tible wall.
A support box or ceiling ¿ restop is required when the
venting passes through a ceiling.
Roof À ashing and a storm collar are required when
venting passes through the roof.
Follow instructions provided with the venting for instal-
lation of these items.
11Heat & Glo • Tiara Petite B • 7026-101 Rev. Q • 10/13
25'
24'
22'
20'
18'
16'
14'
12'
10'
8'
6'
4'
2'
6 in. (152mm) Minimum starter pipe
30 in. (762mm) Maximum Horizontal run with no vertical pipe and with 1/4 in.
(6mm) rise per foot. Must use approved Termination Cap.
C
L
25 ft. (8m)
Maximum Vertical
2' 4' 6' 8' 10' 12' 14' 15'
Termination cap
Termination cap
Example 1
Example 2
Adjust
Intake
Damper
SLK-01TRD or an approved Termination Cap
6 ft. (2m) Minimum
Vertical Termination
VERTICAL DISTANCE
FROM APPLIANCE TO
90° ELBOW
Install Flue
Restrictor
Adjust
Intake
Damper
D. How to Use the Vent Graph E. Venting Guidelines
1. Measure the distance from the top of appliance to the
center of the 90° elbow. On the graph below, draw a
horizontal line from that measurement on the vertical
axis across until it intersects with the slanted line.
2. From the point of this intersection, draw a vertical line to
the bottom of the graph.
3. The point at which this line meets the bottom line of the
graph is the maximum length of the horizontal run.
Example 1: If the vertical dimension from the top of the
appliance to the center of the 90° elbow is 7 ft. (2m), the
horizontal run to the outer wall À ange must not exceed 9
ft.-8 in. (3m).
.
Example 2: If the vertical dimension from the top of the
appliance is 21 ft. (6m), the horizontal run to the outer wall
À ange must not exceed 4 ft.-3 in. (1m).
4. Each 90° elbow is equivalent to 3 ft. (914mm) of vent
pipe and each 45° elbow is equivalent to 1 ft. (305mm)
of vent pipe, and must be subtracted from vent pipe
run. A single vertical to horizontal 90° elbow is already
calculated into the allowable 15 ft. (5m) run. Each
additional 90° elbow reduces the maximum horizontal
distance by 3 ft. (914mm).
Example: The use of three elbows would reduce the
allowable horizontal run to 9 ft. (3 - 1 = 2 elbows
x 3 ft. = 6 ft.; 15 ft. max. - 6 ft. = 9 ft. max.)
Notes:
The maximum horizontal vent run is 15 ft. (5m) when the
vertical vent rise is 10 ft. (3m).
Horizontal sections require a 1/4 in. (6mm) rise for every
12 in. (305mm) of horizontal travel.
Exterior vent diameter = 6-5/8 in. (168mm); Inner vent
diameter = 4 in. (102mm).
Horizontal sections require noncombustible support every
3 ft. (914mm) , e.g. wall straps.
For any vertical termination a minimum of 6 ft. (2m)
vertical must be used.
EXCEPTIONS FOR HORIZONTAL INSTALLATIONS:
*The maximum horizontal vent run is 30 in. (762mm).
*The maximum horizontal vent run with a 45° elbow is
18 in. (457mm).
*No external minimum rise is required.
*The minimum horizontal vent run is 6 in. (152mm).
Figure 5.2
NOTE: In the Commonwealth of Mas-
sachusetts the word damper shall be
replaced with the words À ue restrictor.
12 Heat & Glo • Tiara Petite B • 7026-101 Rev. Q • 10/13
F. Horizontal Termination
Figure 5.3
Type A - Up & Out Installation
90° ELBOW
PIPE LENGTH
PIPE LENGTH
TERMINATION CAP
WALL THIMBLE
WALL THIMBLE COVER
CENTER LINE
WALL THIMBLE
45°
ELBOW
2 in. (51mm) CLEARANCE FROM
STOVE CORNER TO
COMBUSTILE WALL
2 in. (51mm) CLEARANCE FROM STOVE CORNER TO COMBUSTIBLE
WALL
TERMINATION CAP
CENTER LINE
16-5/8 in.
WALL THIMBLE
WALL THIMBLE COVER
(42 cm)
Type C - 45° Elbow in Corner Installation
Type B - Straight Out Installation
Female Locking Lugs
Male Locking Lugs
Step 1.
Determine the desired location of the appliance. Check to
ensure that wall studs or roof rafters are not in the way when
the venting system is attached. If this is the case, you may
want to adjust the location of the appliance.
Figure 5.4
Step 2.
Direct vent pipe is designed with a locking connection. To
connect the venting system to the appliance flue outlet, a
twist-lock adapter is built into the appliance at the factory.
Wall thickness may vary. Remember to include wall
thickness in minimum clearances when figuring venting
lengths for your installation needs.
Note: Female ends of direct vent pipe/elbows are
designed to slide straight onto the male ends of adjacent
pipes by orienting the pipe indentations so they match and
slide into the entry slots on the male ends, see Figure 5.4.
Push the pipe sections completely together, then twist-lock
one section clockwise approximately one-quarter turn, until
the two sections are fully locked. The female locking lugs
may not be visible from the outside. They may be located by
examining the inside of the female ends.
Fire Risk.
Explosion Risk.
Combustion Fume Risk.
Use vent run supports per installation instructions.
Connect vent sections per installation instructions.
Maintain all clearances to combustibles.
Do NOT allow vent to sag below connection
point to appliance.
Maintain speci¿ ed slope (if required).
WARNING
Improper support may allow vent to sag or separate.
Fire Hazard.
Exhaust Fume Risk.
Impaired Performance of Appliance.
WARNING
Ensure vent components are locked together correctly.
Pipe may separate if not properly joined.
13Heat & Glo • Tiara Petite B • 7026-101 Rev. Q • 10/13
NOTE:
(1) Installation requires a minimum of 6 in. (152mm)
horizontal run of vent with a 1/4 in. (6mm) rise run towards
the termination. Each 1 ft. (305mm) of horizontal venting
must include a 1/4 in. (6mm) rise. Never allow the vent
to run downward. This could cause high temperatures
and may present the possibility of a fire.
(2) The location of the horizontal vent termination on an
exterior wall must meet all local and national building
codes, and must not be easily blocked or obstructed,
see Figure 4.4 on page 9.
(3) For installations requiring a vertical rise on the exterior
of the building, a snorkel kit is available with a 14 in.
(356mm) and a 36 in. (914mm) tall snorkel termination
cap. Follow the same installation procedures as used
for standard horizontal terminations. If the snorkel
termination must be installed below grade (i.e. basement
application), proper drainage must be provided to
prevent water from entering the snorkel termination. Do
not backfill around snorkel termination.
HOT
HOT
WOOD
SCREW
WALL THIMBLE
NOTES:
(1) The four wood screws provided should be replaced with
appropriate fasteners for stucco, brick, concrete, or
other types of sidings.
(2) A termination cap with a built-in vinyl siding standoff is
highly recommended on a building with vinyl siding. The
pilot hole will be 2 in. (51mm) closer to the bottom of the
square than the top. Using a framing square, draw a 14
in. x 14 in. (356mm x 356mm) square around the pilot
hole in the siding. See Figure 5.7.
8 in.
(203mm)
7 in.
(178mm)
7 in.
(178mm) 6 in.
(152mm)
Figure 5.6
Figure 5.7
Figure 5.5
CENTER
LINE
CENTER LINE
CENTER OF
HOLE
WALL
THIMBLE
Step 4.
Position the horizontal termination cap in the center of the 10
in. x 10 in. (254mm x 254mm) square hole and run a bead
of non-hardening mastic around its outside edges, so as to
make a seal between it and the wall, attach termination cap
to the exterior wall with the four wood screws provided. The
arrow on the vent cap should be pointing up (Figure 5.6).
Step 3.
For installations using a round support box/wall thimble
(check pipe manufacturer's instructions), mark the wall for a
10 in. x 10 in. (254mm x 254mm) square hole. The center
of the square hole should line up with the center line of the
horizontal pipe, as shown in Figure 5.5. Cut and frame the
hole in the exterior wall where the vent will be terminated. If
the wall being penetrated is constructed of noncombustible
material, i.e. masonry block or concrete, a 7 in. (178mm)
diameter hole is acceptable.
14 Heat & Glo • Tiara Petite B • 7026-101 Rev. Q • 10/13
Step 5.
Place the wall thimble cover over the pipe assembly and
slide the appliance and vent assembly towards the wall,
carefully inserting the vent pipe into the vent termination
cap assembly. It is important that the vent pipe extend into
the vent termination cap a sufficient distance so as to result
in a minimum pipe overlap of 1-1/4 in. (32mm). Secure the
connection between the vent pipe and the vent termination
cap by attaching the two sheet metal strips extending from
the vent termination cap assembly into the outer wall of
the vent pipe. Use the two sheet metal screws provided to
connect the strips to the pipe section (Figure 5.9).
Fold Strap Here
Wall Thimble Cover/Ceiling
Firestop as Required by Local
Jurisdiction
1/4 in. (6mm)
Strap
Sheet Metal Screw
Wall Thimble
Figure 5.9
Burn Risk.
Local codes may require installation of a cap
shield to prevent anything or anyone from
touching the hot cap.
WARNING
WARNING
Do NOT connect a pipe section to a termination cap without
using the telescoping À ue section found on the termination cap.
WALL THIMBLE COVER
WALL THIMBLE
Vinyl siding standoff with siding beneath
removed
SCREWS
Bolt horizontal top to vinyl
standoff
SCREWS
Apply sealant to all four sides
VINYL SIDING
Figure 5.8
(NOTE: Some termination caps may cause the vent
pipe to be off center on flashing). Ensure that proper
clearances to combustible materials are maintained.
If you are not using an approved termination cap with
a built-in standoff on a building with vinyl siding, a
vinyl siding standoff should be installed between the
termination cap and the exterior wall (Figure 5.8).
Follow manufacturer’s instructions for attaching the
vinyl siding standoff to the horizontal termination cap.
The vinyl siding standoff prevents excessive heat from
possibly melting the vinyl siding material. The vent
terminal cap shall not be recessed into a wall or siding.
Remove siding from the area where the standoff will be
located.
Fire Hazard.
Exhaust Fume Risk.
Impaired Performance of Appliance.
WARNING
Ensure vent components are locked together correctly.
Pipe may separate if not properly joined.
Note: The attachment from the vent pipe to the vent
termination cap must be sealed with silicone. Termination
caps shall not be recessed into a wall or siding.
15Heat & Glo • Tiara Petite B • 7026-101 Rev. Q • 10/13
Step 1.
Check the installation instructions for required 1 in. (25mm)
clearances (air space) to combustibles when passing
through ceilings, walls, roofs, enclosures, attic rafters, or
other nearby combustible surfaces. See page 17, Figure
5.16. Check the instructions below for maximum vertical rise
of the venting system, and any maximum horizontal offset
limitations. All offsets must fall within the set parameters of
the vent graph (Figure 5.2) located on page 11.
NOTE: Maximum vertical rise allowable is 25 ft. (8m),
Figure 5.11.
NOTE: Maximum number of 45° elbows permitted for a
vertical installation is eight, provided their installation
does not decrease maximum allowable horizontal run (as
specified by vent graph, on page 11).
Plumber’s Tape
connected to
Wall Strap
Wall Strap
7ZRÛ(OERZV
Step 2.
Set the gas appliance in its desired location. Drop a plumb
bob down from the ceiling to the position of the appliance
flue exit, and mark the location where the vent will penetrate
the ceiling. Drill a small hole at this point. Next, drop a plumb
bob from the roof to the hole previously drilled in the ceiling,
and mark the spot where the vent will penetrate the roof.
Determine if ceiling joists, roof rafters, or other framing will
obstruct the venting system. You may wish to relocate the
appliance, or to offset, as shown in Figure 5.12 to avoid
cutting loadbearing members.
G. Vertical Termination
1. Direct Vent Pipe
Figure 5.10
Figure 5.11
Figure 5.12
VERTICAL
TERMINATION
CAP
STORM
COLLAR
FLASHING
FIRESTOP
PIPE LENGTH
SUPPORT BOX
25 ft. (8m)
MAXIMUM
Fire Risk.
Explosion Risk.
Maintain vent clearance to combustibles as speci-
¿ ed.
WARNING
Do not pack air space with insulation or other
materials.
Failure to keep insulation or other materials away
from vent pipe may cause ¿ re.
16 Heat & Glo • Tiara Petite B • 7026-101 Rev. Q • 10/13
Step 4.
Assemble the desired lengths of pipe and elbows necessary
to reach from the appliance up through the round support
box. Ensure that all pipe and elbow connections are in their
fully twist-locked position. Assemble as instructed.
Step 5.
Cut a hole in the roof centered on the small drill hole placed in
the roof in Step 2. The hole should be of sufficient size to meet
the minimum requirements for clearance to combustibles, as
specified. Continue to assemble lengths of pipe and elbows
necessary to reach from the ceiling support box/wall thimble
up through the roof line. Galvanized pipe and elbows may
be utilized in the attic, as well as above the roofline. The
galvanized finish is desirable above the roofline, due to its
higher corrosion resistance.
NOTE:
(1) If an offset is necessary in the attic to avoid obstructions,
it is important to support the vent pipe every 3 ft.
(914mm) to avoid excessive stress on the elbows, and
possible separation. Wall straps are available for this
purpose, Figure 5.12, page 15.
(2) Whenever possible, use 45° elbows, instead of 90°
elbows. The 45° elbow offers less restriction to the flow
of flue gases and intake air.
Step 7.
Continue to assemble pipe sections until the height of the
vent (before adding the termination cap) meets the minimum
code requirements as outlined in the current CAN/CGA-
B149 Installation Codes (in Canada), the National Fuel
Gas Code NFPA 54/ANSI Z223.1 (in USA), or local codes.
Note that for steep roof pitches, the vent height must be
increased. See roof pitch table (Figure 4.3, on page 8). In
high wind conditions, nearby trees adjoining rooflines, steep
pitched roofs, and other similar factors can result in poor
draft, or down drafting. In these cases increasing the vent
height or switching to the high wind termination cap may
solve this problem.
Step 3.
To install the round support box/wall thimble cover in a flat
ceiling, cut a 10 in. (254mm) square hole in the ceiling,
centered on the hole drilled in Step 2. Frame the hole as
shown in Figure 5.13.
Framing
1 - 1/2 in. (38mm) Long
Wood Screws
Ceiling
Joists
Figure 5.13
Shingles overlap on
top edge of flashing
CAP AND STORM
COLLAR NOT SHOWN
FOR CLARITY
Figure 5.14
Step 8.
Slip the storm collar over the pipe, and push it down to the
top of the flashing (Figure 5.15). Use non-hardening sealant
above and below the joint between the storm collar and the
pipe.
Step 6.
Slip the flashing over the pipe section(s) protruding through
the roof. Secure the base of the flashing to the roof with
roofing nails. Ensure the roofing material overlaps the top
edge of the flashing as shown in Figure 5.14. Verify that the
chimney is the required height above the roof. See roof pitch
table, Figure 4.3, on page 8.
Optional High Wind Termination Cap
Secure Flashing with Non-Hardening
Sealant and Roofing Nails
Figure 5.15
17Heat & Glo • Tiara Petite B • 7026-101 Rev. Q • 10/13
MIN. 1 in. (25mm)
CLEARANCE
CEILING FIRES TOP
NAILS
MIN. 1 in. (25mm)
CLEARANCE
MIN. 1 in. (25mm)
CLEARANCE
MIN. 1 in. (25mm)
CLEARANCE
Figure 5.16
Fire Risk.
Explosion Risk.
WARNING
Any occupied areas above the first floor, including
closets and storage spaces, which the vertical
vent passed through must be enclosed. The
enclosure may be framed and sheetrocked with
standard construction materials; however, refer
to these installation instructions for the minimum
allowable clearance between the outside of the
vent pipe and the combustible surfaces of the
enclosure. Do not fill any of the required air space
with insulation.
Step 9.
Twist-lock the vent cap and seal.
Note: For multi-story vertical installations, a ceiling firestop
is required at the second floor, and any subsequent floors
(Figure 5.16). The opening should be framed to 10 in. x
10 in. (254mm x 254mm) inside dimensions, in the same
manner as shown in Figure 5.13 on page 16.
18 Heat & Glo • Tiara Petite B • 7026-101 Rev. Q • 10/13
2. Cathedral Ceiling
Level
Cathedral Ceiling
Support Box
2 in. (51mm)
Min. below
finished ceiling
Cut hole 1/8 in. (3mm)
greater in size than
pattern of support box
as it is projected onto
roof line
Figure 5.17
Figure 5.18
Step 1.
Follow installation Steps 1 and 2 under vertical installation
section, page 15.
Step 2.
Remove shingles or other roof covering as necessary to cut
the rectangular hole for the support box. Cut the hole 1/8 in.
(3mm) larger than the support box outline.
Step 3.
Lower the support box through the hole in the roof until the
bottom of the support box protrudes at least 2 in. (51mm)
below the ceiling (Figure 5.17). Align the support box both
vertically and horizontally with a level. Temporarily tack the
support box in place through the inside walls and into the
roof sheathing.
Step 4.
Using tin snips, cut the support box from the top corners
down to the roofline, and fold the resulting flaps over the
roof sheathing (Figure 5.18). Before nailing it to the roof,
run a bead of non-hardening mastic around the top edges
of the support box to make a seal between it and the roof.
Clean out any combustible material from inside the support
box.
Step 7.
Complete the cathedral ceiling installation by following the
same procedures outlined in steps 7 through 9 for vertical
installations, pages 16-17.
Step 6.
Place the support clamp (provided with the support box)
inside the support box (at the bottom), and secure to the pipe
section. The clamp allows the support box to support the
weight of the pipe sections. Continue to add pipe sections
until you are above the roofline.
Cathedral
Ceiling
Trim Collar
Screws
Support
Box
Step 8.
Install the black trim collar around the outside of the cathedral
ceiling support box (Figure 5.19). The two pieces of the trim
collar slide over one another to allow for easy adjustment
around the support box. Using the six screws provided,
secure the four corners and the overlapping sections of the
trim collar to the ceiling. You may want to predrill the holes for
the overlapped sections for ease of installation.
Figure 5.19
Step 5.
Assemble the desired lengths of pipe and elbows necessary
to reach from the appliance up through the round support
box. Ensure that all pipe and elbow connections are in their
fully twist-locked position. Assemble as instructed.
19Heat & Glo • Tiara Petite B • 7026-101 Rev. Q • 10/13
3. Class A Metal Chimney
Figure 5.20
TERMINATION
CAP
EXISTING
METAL
CHIMNEY
SYSTEM
TOP
ADAPTOR
FLASHING
4 in. (102mm)
FLEX PIPE
RETRO CONNECTOR
DIRECT VENT PIPE
High Wind Termination
Cap
Sheet Metal Screws
Drill Four 1/8 in.
(3mm) Diameter
Holes
Figure 5.22
Figure 5.23
Step 4.
Pass the flex pipe down through the center of the chimney
system, and center the top adapter on the top of the chimney
pipe. Drill four 1/8 in. (3mm) diameter holes through the
top adapter, and into the chimney top. Ensure that you are
drilling into the metal on the chimney. Twist lock the high
wind termination cap onto the top adapter (Figures 5.22
and 5.23).
Step 5.
Pull the flex pipe down through the ceiling support box, until
it protrudes approximately 3 in. (76mm). Connect the flex
pipe to the retro connector, and attach with sheet metal
screws.
Step 6.
Push the flex pipe back up into the ceiling support box,
center the retro connector, and attach it to the support box
with sheet metal screws.
Step 7.
The connection between the appliance and the retro
connector may be completed with sections of direct vent
pipe.
Top Adapter
Sheet Metal Screws
Flex Pipe
Figure 5.21
Step 1.
Remove existing chimney cap.
Step 2.
Measure the distance from the top of the chimney to the
bottom of the ceiling support box, add 3 in. (76mm) to this
measurement, and cut a section of 4 in. (101mm) flex pipe to
that length (the flex should be fully extended).
Step 3.
Connect the end of the flex pipe section to the underside of
the top adapter, using four sheet metal screws (Figure 5.21).
CAUTION
Ensure that existing chimney is functionally sound and clean.
Have inspection done by qualified chimney sweep or
professional installer BEFORE converting to direct vent
appliance.
20 Heat & Glo • Tiara Petite B • 7026-101 Rev. Q • 10/13
4. Existing Masonry Chimney
Type C - Up & Out Installation Type D - Hearth Mount
Figure 5.24
CHIMNEY LINER
TERMINATION
CAP
3 in. (76mm)
FLEX LINER
SHOWING TWO
25 ft. (8m)
SECTIONS OF
FLEX LINER
CO-AXIAL TO
CO-LINEAR
CONNECTOR
PIPE LENGTH
OPTIONAL
CHIMNEY LINER
TERMINATION CAP
25 ft. (8m) OF 3 in.
(76mm) FLEX LINER
THIS SECTION OF THE
CHIMNEY MUST BE
SEALED
CHIMNEY MUST BE SEALED
FROM 4 ft. (1m) SECTION TO
TERMINIATION USING A
SMOKE SHELF OR A
DAMPER*. SEAL SHOULD BE
6 in. (152mm) BELOW END OF
4 ft. (1m) AIR INTAKE
SECTION.
CO-AXIAL TO CO-LINEAR
CONNECTOR
4 ft. (1m) OF 3 in. (76mm)
FLEX LINER AIR INTAKE
SECTION
ALCOVE CLEARANCE
TO COMBUSTIBLES
MUST BE MAINTAINED.
CHIMNEY LINER
TERMINATION CAP
25 ft. (8m) OF 3 in.
(76mm) FLEX
LINER EXHAUST
SECTION
THIS SECTION OF
THE CHIMNEY MUST
BE SEALED
THE CHIMNEY MUST BE
SEALED FROM THE 4 ft. (1m)
SECTION TO TERMINATION
USING A SMOKE SHELF OR A
DAMPER. THE SEAL SHOULD
BE 6 in. (152mm) BELOW THE
END OF THE 4 ft. (1m) AIR
INTAKE SECTION.
4 ft. (1m) OF 3 in.
(152mm) FLEX LINER
AIR INTAKE SECTION
CO-AXIAL TO
CO-LINEAR
CONNECTOR
PIPE LENGTH
OPTIONAL
TERMINATION
CAP
FLASHING
4 in. (1m) FLEX
LINER
TOP ADAPTOR
RETRO
CONNECTOR
90 DEGREE
ELBOW
DIRECT
VENT PIPE
Type A & B Co-Axial to Co-Linear
*In the Commonwealth of Massachusetts, the word damper
shall be replaced with the words flue restrictor.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50

Heat & Glo Tiara Petite-B TiaraP Install Manual

Catégorie
Cheminées
Taper
Install Manual

dans d''autres langues