Aube Technologies TH104PLUS Le manuel du propriétaire

Catégorie
Thermostats
Taper
Le manuel du propriétaire
TH104PLUS
Programmable Thermostat
Owners
Guide
69-2691EF-01.book Page -1 Tuesday, November 29, 2011 1:34 PM
Overview
About your new thermostat ................................................................... 1
Controls ................................................................................................. 2
Display................................................................................................... 3
Installation
Installation guidelines ............................................................................ 4
Wiring .................................................................................................... 5
Thermostat mounting ............................................................................ 6
Clock and day setting ............................................................................ 7
Operation
Automatic (Auto) mode.......................................................................... 8
Manual (Man) mode ............................................................................ 10
Away mode.......................................................................................... 10
Standby mode ..................................................................................... 10
Appendices
Advanced settings ............................................................................... 11
In case of difficulty...............................................................................14
Resetting the thermostat (default settings)..........................................15
Power outage ...................................................................................... 16
Specifications ...................................................................................... 16
3-year limited warranty ........................................................................17
Customer Assistance ..........................................................................18
Table of contents
69-2691EF-01.book Page 0 Tuesday, November 29, 2011 1:34 PM
TH104PLUS
1
This thermostat is designed to control an electric heating system such as a
baseboard heater, a radiant ceiling, a convector or a fan-forced heater.
The thermostat CANNOT be used with:
a resistive load under 0.83 A
a resistive load over 14.6 A
a system driven by a contactor or a relay (inductive load)
a central heating system
SUPPLIED PARTS
One (1) thermostat
Two (2) 6-32 mounting screws
Two (2) solderless connectors
About your new thermostat
Do you need assistance?
We are here to help.
Call 1-800-831-2823.
69-2691EF-01.book Page 1 Tuesday, November 29, 2011 1:34 PM
Owner’s Guide
2
Controls
Mode button
(see pages 8 & 10)
Day button
Hour button
Program button
Minute button
Up and Down buttons
Return button
Backlit screen *
* The screen is backlit for 12 seconds when you press any button.
69-2691EF-01.book Page 2 Tuesday, November 29, 2011 1:34 PM
TH104PLUS
3
Display
Time and day
Appears when power to
the thermostat is cut off
(see page 7)
Setpoint
temperature *
Appears if the
thermostat is configured
for a fan-forced heater
(see page 11)
Period indicator
(see page 8)
Indicates that the settings
are locked (see page 11)
Room temperature
Heating intensity indicator
Mode indicator
(see pages 8 & 10)
* To display the set temperature (setpoint), press the Up or Down
button once. The thermostat will display the setpoint instead of the
clock for 5 seconds.
69-2691EF-01.book Page 3 Tuesday, November 29, 2011 1:34 PM
Owner’s Guide
4
TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN
POWER PANEL TO AVOID ELECTRICAL SHOCK.
All cables and connections must comply with local electrical
codes.
This thermostat has tinned copper wires for line and load connec-
tions. Special CO/ALR solderless connectors must be used if
these wires will be connected to aluminium conductors.
Install the thermostat onto an electrical box.
Install the thermostat about 1.5 m (5’) high, on an inside wall facing
the heater.
Avoid locations where there are air drafts (such as the top of a
staircase or an air outlet), dead air spots (such as behind a door),
or direct sunlight.
Do not install the thermostat on a wall that conceals chimney or
stove pipes.
The thermostat wires are not polarized; either wire can be con-
nected to the load or to the power supply.
Installation guidelines
69-2691EF-01.book Page 4 Tuesday, November 29, 2011 1:34 PM
TH104PLUS
5
Connect the thermostat wires to the power and to the load using
solderless connectors for copper wires.
Wiring
69-2691EF-01.book Page 5 Tuesday, November 29, 2011 1:34 PM
2-wire Installation 4-wire Installation
Owner’s Guide
6
Push the excess wires back inside the
electrical box.
Secure the thermostat to the electrical
box using the provided screws.
Insert the screws through either the
right or left pair of mounting holes on
the thermostat.
NOTE: If there is a protective film or
sticker on the thermostat’s screen, peel it
off.
Apply power to the heating system. Verify the installation by
checking that the heater can be turned on by raising the setpoint
using the Up button and off by lowering the setpoint using the
Down button.
WARNING: Keep the thermostat's air vents clean and free from
obstructions.
Thermostat mounting
69-2691EF-01.book Page 6 Tuesday, November 29, 2011 1:34 PM
TH104PLUS
7
1) Press the Day button
to set the day.
2) Use the Hour and Min
buttons to set the
clock.
3) Press the button to
exit.
Clock and day setting
69-2691EF-01.book Page 7 Tuesday, November 29, 2011 1:34 PM
The clock must be set
when the time is incorrect
or flashes on the screen.
Owner’s Guide
8
In Automatic mode, the thermostat adjusts its temperature set-
point according to the period of the day. To place the thermostat in
this mode, press the Mode button until Auto appears on the
screen. The current period name also appears (unless the ther-
mostat has not been programmed with a schedule).
You can program up to 4 periods (Wake, Leave, Return or Sleep)
in a day. You can set 2 different programs: one for the weekdays
(Monday to Friday) and another one for the weekend (Saturday
and Sunday).
The thermostat uses the following default schedule:
Temporary Override
You can temporarily modify the setpoint temperature while the thermostat is in
Automatic mode using the Up or Down button. The new setpoint will be used until
the beginning of the next period. During the override, Auto flashes on the screen.
You can cancel the override by pressing the button.
Automatic mode
Monday to Friday Saturday & Sunday
Period Start Time Temperature Start Time Temperature
Wake 6:00 21.0°C (70°F) 6:00 21.0°C (70°F)
Leave 8:00 16.5°C (62°F) --:-- - -
Return 18:00 21.0°C (70°F) --:-- - -
Sleep 22:00 16.5°C (62°F) 22:00 16.5°C (62°F)
69-2691EF-01.book Page 8 Tuesday, November 29, 2011 1:34 PM
TH104PLUS
9
To modify the schedule:
1) Press the Pgm button. Each time you press
the Pgm button, the thermostat displays
one of the periods of the schedule in the
following order:
2) Press the Hour and Min buttons to set the
start time of the displayed period.
NOTE: To cancel the period, press the
Mode button. Instead of displaying the start
time of the period, the thermostat will dis-
play --:--. During operation, the thermostat
will skip over that period.
3) Press the Up or Down button to set the
temperature.
4) To set another period, press the Pgm
button and repeat steps 2 and 3.
5) Press the button to return to normal
display.
Automatic mode (cont’d)
Weekdays
(MO TU WE TH FR)
Weekend
(SA SU)
12341234
69-2691EF-01.book Page 9 Tuesday, November 29, 2011 1:34 PM
Owner’s Guide
10
To place the thermostat in Manual mode, press the Mode
button until Man appears on the screen. In this mode, any
modification to the temperature setpoint must be done
manually. To set the temperature, press the Up or Down
button. The default setting is 21.0°C (70°F).
To place the thermostat in Away mode, press the Mode button
until Away appears on the screen. This mode is a quick way to
lower the temperature to a predetermined setting before you go
away for an extended length of time. The temperature is 15.0°C
(59°F) by default and can be modified using the setup menu
(see page 11).
To disable heating, press the Mode button until Standby
appears on the screen. In this mode, the setpoint temperature
cannot be displayed or modified. For frost protection, heating
will turn on only to prevent the room temperature from dropping
below 5°C (41°F).
Manual (Man) mode
Away mode
Standby mode
69-2691EF-01.book Page 10 Tuesday, November 29, 2011 1:34 PM
TH104PLUS
11
1) Press the Pgm button for 3
seconds.
2) To display the next parameter,
press the Pgm button.
3) To modify the displayed
parameter, press the Up or
Down button.
4) To exit the menu, press the
button or do not press any
button for 1 minute.
Advanced settings
69-2691EF-01.book Page 11 Tuesday, November 29, 2011 1:34 PM
The first parameter
appears when the
menu is displayed.
Owner’s Guide
12
Advanced settings (cont’d)
Display Parameter Options Default setting
Temperature unit °C / °F °C
Time format 12 hr / 24 hr 24 hr
Fan1No / Yes No
Away temperature25.0°C - 30.0°C (41°F - 86°F) 15.0°C (59°F)
Daylight Saving Time3On / Off Off
Year400 - 99 09
Month401 -12 01
Day401 - 31 01
Early Start5On / Off Off
Minimum setpoint 5.0°C - 30.0°C (41°F - 86°F) 5.0°C (41°F)
Maximum setpoint 5.0°C - 30.0°C (41°F - 86°F) 30.0°C (86°F)
Keypad lock6On / Off Off
69-2691EF-01.book Page 12 Tuesday, November 29, 2011 1:34 PM
TH104PLUS
13
1 Fan
Place at Yes if you have a fan-forced heater (to prevent premature burnout of the motor).
Leave at No for better temperature regulation if you do not have a fan-forced heater.
2 Away temperature
Set the temperature you wish to use when the thermostat is in Away mode (see
page 10).
3 Daylight Saving Time
When the Daylight Saving Time function is enabled (On), the thermostat automatically
switches to Daylight Saving Time on the second Sunday of March and to normal time on
the first Sunday of November.
4 Year, Month, Day
These parameters are available only if the Daylight Saving Time function is enabled
(On).
5 Early Start
Early Start is used in Automatic mode only. When Early Start is enabled (On), the
thermostat determines when to start heating so the desired temperature is attained at
the beginning of Wake and Return periods. When Early Start is disabled (Off), heating
starts only at the beginning of Wake and Return periods; thus there is a delay before
you reach the desired temperature.
6 Keypad lock
The settings are locked. The temperature adjustment buttons only allow you to view the
temperature setpoint.
Advanced settings (cont’d)
69-2691EF-01.book Page 13 Tuesday, November 29, 2011 1:34 PM
Owner’s Guide
14
In case of difficulty
PROBLEM SOLUTIONS
Thermostat is hot. This condition is normal. Ensure that the heater capac-ity does
not exceed the thermostat’s maximum load.
Wrong temperature is
displayed.
Correct it if any of the following situations exists:
• The thermostat is exposed to an air draft.
The thermostat is located near or above a heat source
such as a light dimmer.
Wrong time is displayed. The thermostat was without power for more than 5
hours. See page 7 to set time.
Temperature does not
change according to the
programmed schedule.
Check that the thermostat is in Automatic mode. Check the
schedule and clock settings. If the thermo-stat is configured
in 12-hour format, ensure that PM appears on the screen
when afternoon times are dis-played.
LP appears on the screen
or the screen is blank
despite there is no power
outage.
The thermal circuit breaker in the heater is opened. This can
happen if the heater is obstructed by furniture or curtain and
has overheated, or if the thermal circuit breaker is defective or
too sensitive.
The settings cannot be
changed. The settings are locked (see page 13).
69-2691EF-01.book Page 14 Tuesday, November 29, 2011 1:34 PM
LO is displayed. The measured temperature is below the display range. Heating
is activated.
HI is displayed. The measured temperature is above the display range.
E1, E2 is displayed. The thermostat performance is reduced due to a sensor error.
Please contact technical support for more information.
TH104PLUS
WARNING: All parameters, except the clock (time and day), return to
their default settings when the thermostat is reset.
1) Press the Mode button until Standby appears on the screen.
2) Press the button for 6 seconds.
3) The thermostat will display rSt (reset) for 2 seconds to indicate it is
reset and will then return to normal display.
During a power outage, LP (low power) appears for the first minute.
Then the screen becomes blank. The settings are stored in memory.
After the initial installation, product must be connected to power for a
minimum of two hours to enable the power outage feature. However, if
the power failure exceeds 4 hours, the thermostat's clock must be re-
adjusted and, if you are using the automatic Daylight Saving Time
changeover function, it must be re-enabled. When power returns, the
thermostat will return to the mode of operation active prior to the power
failure.
Resetting the thermostat (default settings)
Power outage
69-2691EF-01.book Page 15 Tuesday, November 29, 2011 1:34 PM
15
Owner’s Guide
16
Supply: 120/240 V AC, 60 Hz
Minimum load: 0.83 A (resistive only)
200 W @ 240 V AC
100 W @ 120 V AC
Maximum load: 14.6 A (resistive only)
3500 W @ 240 V AC
1750 W @ 120 V AC
Specifications
69-2691EF-01.book Page 16 Tuesday, November 29, 2011 1:34 PM
Display range: 0°C to 50.0°C (32°F to 99°F)
Setpoint range: 5.0°C to 30.0°C (41°F to 86°F)
Resolution: 0.5°C (1°F)
Storage temperature: -20°C to 50°C (-4°F to 120°F)
ICES-003 Class B Notice: This Class B digital apparatus
complies with Canadian ICES-003.
273699
Energy Verified
Only
TH104PLUS
Resideo warrants this product, excluding battery, to be free from defects in workmanship or
materials, under normal use and service, for a period of three (3) years from the date of first
purchase by the original purchaser. If at any time during the warranty period the product is
determined to be defective due to workmanship or materials, Resideo shall repair or replace it
(at Resideo’s option). If the product is defective,
(i) return it, with a bill of sale or other dated proof of purchase, to the place from which
you purchased it; or
(ii) call Resideo Customer Care at 1-800-831-2823. Customer Care will make the
determination whether the product should be returned to the following address:
Resideo Return Goods, Dock 4 MN10-3860, 1985 Douglas Dr. N., Golden Valley, MN
55422, or whether a replacement product can be sent to you.
This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it
is shown by Resideo that the defect was caused by damage which occurred while the product
was in the possession of a consumer.
Resideo’s sole responsibility shall be to repair or replace the product within the terms stated
above. RESIDEO SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND,
INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY
OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR
ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or
limitation of incidental or consequential damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY RESIDEO MAKES ON THIS
PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS
HEREBY LIMITED TO THE THREE YEAR DURATION OF THIS WARRANTY. Some states
do not allow limitations on how long an implied warranty lasts, so the above limitation may not
apply to you.
This warranty gives you specific legal rights, and you may have other rights which vary from
state to state. If you have any questions concerning this warranty, please write Resideo
Customer Care, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800-831-2823.
3-year limited warranty
69-2691EF-01.book Page 17 Tuesday, November 29, 2011 1:34 PM
Owner’s Guide
18
If you have any questions about the product, contact us at:
Tel: 1-800-831-2823
CAUTION: ELECTRONIC WASTE NOTICE
The product should not be disposed of with other household waste. Check
for the nearest authorized collection centers or authorized recyclers. The
correct disposal of end-of-life equipment will help prevent negative
consequences for the environment and human health.
FCC statement available: https://customer.resideo.com/en-US/support/
residential/codes-and-standards/FCC15105/Pages/default.aspx
Printed in USA
69-2691EF-0903-2022
Customer Assistance
69-2691EF-01.book Page 18 Tuesday, November 29, 2011 1:34 PM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Aube Technologies TH104PLUS Le manuel du propriétaire

Catégorie
Thermostats
Taper
Le manuel du propriétaire

dans d''autres langues