Bull NovaScale R430 F2 Guide de démarrage rapide

Taper
Guide de démarrage rapide
NovaScale R430 F2
Getting Started With Your
System
Guide de mise en route
NOVASCALE
REFERENCE
86 X1 61FD 00
NOVASCALE
NovaScale R430 F2
Getting Started With Your System
Guide de mise en route
Hardware/Matériel
November/Novembre 2009
BULL CEDOC
357 AVENUE PATTON
B.P.20845
49008 ANGERS CEDEX 01
FRANCE
REFERENCE
86 X1 61FD 00
The following copyright notice protects this book under Copyright laws which prohibit such actions as, but not limited
to, copying, distributing, modifying, and making derivative works.
Copyright © Bull SAS
2009
Copyright © 2008 Dell Inc. All rights reserved
Trademarks and Acknowledgements
Citrix and XenServer are trademarks of Citrix Systems, Inc. and/or more of its subsidiaries, and may be registered in
the United States
Patent and Trademark Office and in other countries. Intel and Xeon are registered trademarks of Intel
Corporation in the U.S. and other countries; Microsoft, Hyper-V, Windows, and Windows Server are
either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other
countries. Red Hat and Enterprise Linux are registered trademarks of Red Hat, Inc. in the United States
and other countries; SUSE is a registered trademark of Novell, Inc., in the United States and other
countries. VMware is a registered trademark of VMware, Inc. in the United States and/or other
jurisdictions.
Other trademarks and trade names may be used in this document to refer to either the entities claiming
the marks and names or their products. Bull disclaims any proprietary interest in trademarks and
trade names other than its own.
We acknowledge the rights of the proprietors of the trademarks mentioned in this manual.
All brand names and software and hardware product names are subject to trademark and/or patent protection.
Quoting of brand and product names is for information purposes only and does not represent trademark
misuse.
The information in this document is subject to change without notice. Bull will not be liable for errors
contained herein, or for incidental or consequential damages in connection with the use of this material.
Getting Started
With Your System
book.book Page 1 Tuesday, December 1, 2009 8:36 AM
Notes, Cautions, and Warnings
NOTE: A NOTE indicates important information that helps you make better use
of your computer.
WARN ING : A WARNING indicates a potential for property damage,
personal injury, or death.
____________________
book.book Page 2 Tuesday, December 1, 2009 8:36 AM
Getting Started With Your System 3
Installation and Configuration
WA RNIN G: Before performing the following procedure, review the safety
instructions that came with the system.
Unpacking the System
Unpack your system and identify each item.
Installing the Rails and System in a Rack
Assemble the rails and install the system in the rack following the safety
instructions and the rack installation instructions provided with your system.
book.book Page 3 Tuesday, December 1, 2009 8:36 AM
4 Getting Started With Your System
Optional – Connecting the Keyboard, Mouse, and Monitor
Connect the keyboard, mouse, and monitor (optional).
The connectors on the back of your system have icons indicating which cable to
plug into each connector. Be sure to tighten the screws (if any) on the monitor's
cable connector.
Connecting the Power Cables
Connect the system’s power cable(s) to the system and, if a monitor is used,
connect the monitors power cable to the monitor.
book.book Page 4 Tuesday, December 1, 2009 8:36 AM
Getting Started With Your System 5
Installing the Power Cord Retention Bracket
Attach the power cord retention bracket on the right bend of the power supply
handle. Bend the system power cable into a loop as shown in the illustration and
attach to the bracket’s cable clasp.
Plug the other end of the power cable(s) into a grounded electrical outlet
or a separate power source such as an uninterrupted power supply (UPS)
or a power distribution unit (PDU).
Turning On the System
Press the power button on the system and the monitor. The power indicators
should light.
book.book Page 5 Tuesday, December 1, 2009 8:36 AM
6 Getting Started With Your System
Installing the Optional Bezel
Install the bezel (optional).
Operating System Installation
The NovaScale R430 F2 offers an embedded Configuration utility: the Unified
Server Configurator - Lifecycle Controller Enabled (USC-LCE), which includes
an OS Deployment Wizard that assists you with the installation of the Operating
System.
Refer to the technical characteristics of the server on
http://www.bull.com/novascale
to get the list of supported operating systems.
NOTE: The list of operating systems offered by the USC may be larger than the
list of the supported Operating Systems.
NOTE: for the installation of a supported Operating System not listed in the USC,
see
http://support.bull.com
.
Residing on an embedded flash memory card, USC-LCE is similar to a BIOS
utility in that it can be started during the boot sequence and can function
independently of an installed operating system.
USC-LCE provides drivers that may be required for operating system
installation, depending on which operating system you are installing. The OS
Deployment wizard extracts these drivers and copies them to a staging directory.
These files are deleted after an 18-hour period or when you press the <F10> key
to either cancel operating system installation or re-enter USC after rebooting.
book.book Page 6 Tuesday, December 1, 2009 8:36 AM
Getting Started With Your System 7
NOTE: During the 18-hour period when the drivers are extracted to the temporary
location, you cannot update USC, drivers, or diagnostics using a Driver Update
Package after the operating system is installed, or the Driver Update Package will
display a message that another session is open.
For supported Microsoft® Windows® operating systems, these extracted
drivers are installed during the operating system installation. For supported
Linux operating systems, you must manually install the extracted drivers after
the operating system installation is complete.
Before installing the operating system, the OS Deployment wizard detects if a
boot device is available. A boot device is a physical disk, virtual disk, or other
storage device on which the operating system can be installed.
To begin installation
1
Connect the keyboard, monitor, mouse, and any additional peripherals to
your system.
2
Turn on the system and the attached peripherals.
3
Press
<F10>
in the POST to start the System Services.
NOTE: The Initializing UEFI. Please wait... and the Entering System Services...Starting
Unified Server Configurator messages are displayed.
4
Click
OS Deployment
in the left pane.
5
Click
Deploy OS
in the right pane.
NOTE: If your system has a RAID controller, you have the option of launching the RAID
Configuration wizard and configuring a virtual disk as the boot device.
NOTE: If your system does not have a RAID controller, the OS Deployment wizard
bypasses the RAID configuration option and goes directly to "Select an Operating System".
If your system does not have a RAID controller or if you choose to bypass the optional RAID
configuration, the OS Deployment wizard installs the operating system to a default location,
which is typically the disk identified as Disk 0 in the BIOS utility.
6
Select the operating system you want to install, and click
Next
.
book.book Page 7 Tuesday, December 1, 2009 8:36 AM
8 Getting Started With Your System
7
USC or USC - LCE extracts the drivers required by the operating system you
selected. The drivers are extracted to an internal USB drive named
OEMDRV.
NOTE: For Red Hat® Enterprise Linux® 4.x server and Red Hat Enterprise Linux 5.x
server, the drivers are extracted to OEMDRV under /oemdrv/*.rpm.
For SUSE® Linux Enterprise Server 10 SP2, the drivers are extracted under
/linux/suse/x86_64-sles10/install/*.rpm.
NOTE: The process for extracting the drivers may take several minutes.
NOTE: All drivers copied by the OS Deployment wizard are removed after 18 hours. You
must complete the operating system installation within 18 hours for the copied drivers to be
available. To remove the drivers before the 18-hour period is over, reboot the system and
press the <F10> key to re-enter USC.
8
After the drivers are extracted, USC or USC - LCE prompts you to insert the
operating system installation media.
NOTE: When installing the Microsoft Windows operating system, the extracted drivers are
automatically installed during the operating system installation. When installing the Linux
operating system, the operating system installation uses native drivers. After the Linux
installation is complete, you need to manually install the drivers extracted by USC. See
"Update Drivers for Linux Systems Only".
9
Insert the operating system installation media when prompted and click
Next
.
NOTE: USC-LCE supports internal SATA optical drives, USB optical drives, and virtual
media devices. If the installation media is corrupt or not readable, then USC may be unable to
detect the presence of a supported optical drive. In this case, you may receive an error
message stating that no optical drive is available. If the media is not valid (if it is the incorrect
CD or DVD, for example), a message displays requesting that you insert the correct
installation media.
book.book Page 8 Tuesday, December 1, 2009 8:36 AM
Getting Started With Your System 9
10
Click Finish to reboot the system and continue with the operating system
installation. Upon reboot, the system boots to the operating system
installation media.
NOTE: When the system reboots after you click Finish, you may be prompted to press a
key before booting to the operating system installation media. If you do not press a key, the
system boots to the hard drive and not the operating system installation media.
NOTE: : In the event that the operating system installation is interrupted and the system
reboots before installation completes, you may be prompted to press a key in order to boot
from the operating system installation media.
NOTE: You can cancel the operating system installation by pressing the <F10> key.
Pressing the <F10> key at any point during the installation process or while rebooting causes
any drivers provided by the OS Deployment wizard to be removed.
NOTE: Microsoft Windows Server 2008 UEFI operating system installations are not
currently supported.
CAUTION: During Red Hat 5.x installation, you will receive a warning that a read-only
file system was detected; Linux has detected the temporary storage area of USC that stores
updates for your system. Click OK, and a second warning will appear indicating that the
read-only file system has a loop partition layout and that it needs to be formatted. Click the
Ignore drive button. You may see both warnings several times during the course of Red Hat
5.x installation.
CAUTION: During the beginning of Windows Server® 2003 installation, the installer
will automatically detect and possibly assign the default drive letter C to the USC temporary
storage device OEMDRV. Creating a new Windows-bootable system partition on the hard
drive will assign the partition to a drive letter other than C; this is standard Windows
installer behaviour. To assign the new partition to C, see "Assign a Windows-Bootable
System Partition to the C: Drive".
Update Drivers for Linux Systems Only
On the following operating systems, it is advised to update your system with the
extracted drivers after installation. The drivers are extracted to a drive (or
device) named OEMDRV.
Red Hat Enterprise Linux 4.7 server - The location of the drivers on the
OEMDRV drive after installation is:
/oemdrv/*.rpm
Red Hat Enterprise Linux 5.2 server - The location of the drivers on the
OEMDRV drive after installation is:
/oemdrv/*.rpm
SUSE Linux Enterprise Server 10 with Service Pack 2 - The location of the
drivers on the OEMDRV drive after installation is:
/linux/suse/x86_64-
sles10/install/*.rpm
Use the following command to install the drivers: rpm -Uvh *.rpm.
book.book Page 9 Tuesday, December 1, 2009 8:36 AM
10 Getting Started With Your System
NOTE: If the command rpm –Uvh *.rpm fails to install a driver because a newly
version of the DKMS package is needed, see the
http://support.bull.com
website to
download the latest version of the DKMS package, then:
install this DKMS package by launching the command:
rpm –Uvh dkms <version-release>.noarch.rpm
install the Linux drivers by launching the command:
find ./* -not –name dkms* -exec rpm –Uvh {} \;
Kickstart Installation for the Linux Operating System
If you are using a kickstart installation for the Linux operating system, provide
the following information in the post-installation script:
Command to mount the USB device containing the operating system drivers
labeled OEMDRV.
For example:
mkdir OEMDRV
mount /dev/sdc1 /mnt/OEMDRV
Path to the operating system drivers on the OEMDRV drive:
For Red Hat Enterprise Linux:
/oemdrv/*.rpm
For SUSE Linux Enterprise Server:
/linux/suse/x86_64-sles10/install/*.rpm
Command to install the drivers:
rpm -Uvh *.rpm
Assign a Windows-Bootable System Partition to the C: Drive
After you have completed the USC or USC - LCE portion of Windows Server
2003 installation, your server will reboot and begin the text-mode portion of the
installation. During this phase, you may need to perform the following steps to
ensure Windows installs to your C: drive.
NOTE: Following these instructions after Windows Server 2003 setup presents
you with a list of existing drive partitions and/or unpartitioned space available on
your computer.
1
Select the unpartitioned space, and then press <c> to create a hard-disk
partition. Follow the on-screen instructions to create a partition.
NOTE: The partition may not be enumerated as a C: drive.
2
Select the newly-created partition, and then press <d> to delete the partition.
Follow the on-screen instructions to delete the partition.
book.book Page 10 Tuesday, December 1, 2009 8:36 AM
Getting Started With Your System 11
3
Select the unpartitioned space again, and then press <c> to create a primary
hard-disk partition.
NOTE: The partition will now be enumerated as C: drive.
4
Follow the on-screen instructions to create a partition. Windows will now
install on the C: drive.
For more information on assigning the Windows-bootable system partition to
the C: drive, see
http://support.microsoft.com/kb/896536
.
Other Information You May Need
WA RNIN G: See the safety and regulatory information that shipped with your
system. Warranty information may be included within this document or as
a separate document.
The rack documentation included with your rack solution describes how to
install your system into a rack.
•The
Hardware Owners Manual
provides information about system features
and describes how to troubleshoot the system and install or replace system
components. This document is available online at
http://support.bull.com/documentation.
Any media that ships with your system that provides documentation and
tools for configuring and managing your system, system management
software, system updates, and system components that you purchased with
your system.
NOTE: Always check for updates on
http://support.bull.com
and read the
updates first because they often supersede information in other documents.
Obtaining Technical Assistance
If you do not understand a procedure in this guide or if the system does not
perform as expected, see
http://support.bull.com/documentation
for further
documentation, or contact your support representative; the phone directory is at
http://support.bull.com
.
book.book Page 11 Tuesday, December 1, 2009 8:36 AM
12 Getting Started With Your System
Technical Specifications
Processor
Processor type Intel
®
Xeon
®
processor 5500 series
Expansion Bus
Bus type PCI Express Generation 2
Expansion slots One full-height, half-length x16 link
Memory
Architecture 1066 or 1333 MHz DDR3 registered or
unbuffered Error Correcting Code (ECC)
DIMMs.
Memory module sockets Eight 240-pin
Memory module capacities 1 GB, 2 GB, 4 GB, or 8 GB
Minimum RAM 1 GB (one processor) or 2 GB (two processors)
Maximum RAM 32 GB (one processor) or
64 GB (two processors)
Drives
Hard drives Up to four 3.5-inch, cabled or hot-swap SAS or
SATA internal drives
or
Up to four 2.5-inch, hot-swap SAS, SATA,
or SSD internal drives
Diskette drive Optional external USB 1.44-MB
Optical drive One optional internal slimline SATA
DVD-ROM or DVD+/-RW drive
NOTE: DVD devices are data only.
Optional external USB DVD-ROM
Connectors
Back
book.book Page 12 Tuesday, December 1, 2009 8:36 AM
Getting Started With Your System 13
NIC
Two RJ-45 (for integrated 1-GB NICs)
Serial
9-pin, DTE, 16550-compatible
USB
Two 4-pin, USB 2.0-compliant
Video
15-pin VGA
Front
Video
15-pin VGA
USB
Two 4-pin, USB 2.0-compliant
Internal
USB
Two 4-pin, USB 2.0-compliant
Video
Video type Matrox G200, integrated in Winbond
WPCM450
Video memory 8 MB
Power
AC power supply
(per power supply)
Wattage
480W (non-redundant power supply)
500W (redundant power supply)
Vo l t a g e
100-240 VAC, 50/60 Hz, 7.5-3.8 A
(non-redundant power supply)
100-240 VAC, 50/60 Hz, 7-3.5 A
(redundant power supply)
Heat dissipation
1637 BTU/hr maximum
(non-redundant power supply)
1706 BTU/hr maximum
(redundant power supply)
Maximum inrush current
Under typical line conditions and over
the entire system ambient operating range, the
inrush current may reach 25 A per power
supply for 10 ms or less.
Connectors (continued)
book.book Page 13 Tuesday, December 1, 2009 8:36 AM
14 Getting Started With Your System
Batteries
System battery
CR 2032 3.0-V lithium ion coin cell
Physical
Height 4.3 cm (1.69 in)
Width 43.4 cm (17.09 in)
Depth 62.7 cm (24.69 in)
Weight (maximum configuration) 15.9 kg (35.02 lb)
Environmental
Temperature
Operating
10° to 35°C (50° to 95°F) with a maximum
temperature gradation of 10°C per hour
NOTE: For altitudes above 2950 feet, the
maximum operating temperature is derated
1ºF/550 ft.
Storage
–40° to 65°C (–40° to 149°F) with a maximum
temperature gradation of 20°C per hour
Relative humidity
Operating
20% to 80% (noncondensing) with a maximum
humidity gradation of 10% per hour
Storage
5% to 95% (noncondensing)
Maximum vibration
Operating
0.26 Grms at 5–500 Hz for 15 min
Storage
1.54 Grms at 10–250 Hz for 15 min
Maximum shock
Operating
One shock pulse in the positive z axis
(one pulse on each side of the system) of 31 G
for 2.6 ms in the operational orientation
Power (continued)
book.book Page 14 Tuesday, December 1, 2009 8:36 AM
Getting Started With Your System 15
Storage
Six consecutively executed shock pulses in the
positive and negative x, y, and z axes
(one pulse on each side of the system) of 71 G
for up to 2 ms
Altitude
Operating
–16 to 3048 m (–50 to 10,000 ft)
NOTE: For altitudes above 2950 feet, the
maximum operating temperature is derated
1ºF/550 ft.
Storage
–16 to 10,600 m (–50 to 35,000 ft)
Airborne Contaminant Level
Class
G2 or lower as defined by ISA-S71.04-1985
Environmental (continued)
book.book Page 15 Tuesday, December 1, 2009 8:36 AM
16 Getting Started With Your System
book.book Page 16 Tuesday, December 1, 2009 8:36 AM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38

Bull NovaScale R430 F2 Guide de démarrage rapide

Taper
Guide de démarrage rapide

dans d''autres langues