LG LW1016ER Le manuel du propriétaire

Taper
Le manuel du propriétaire

Ce manuel convient également à

www.lg.com
ENGLISH
Copyright © 2017-2018 LG Electronics Inc. All Rights Reserved.
OWNER’S MANUAL
AIR
CONDITIONER
Read this owners manual thoroughly before operating the appliance
and keep it handy for reference at all times.
TYPE: WINDOW
MFL70960704
Rev.00_082418
OWNERS MANUAL
AIR
CONDITIONER
LW1016ER
LW1216ER
FRANÇAIS
2
TABLE OF CONTENTS
TABLE OF CONTENTS
11 How to Install the Unit
11 Window Requirements
11 Preparation of Cabinet
12 Cabinet Installation
15 OPERATION
15 Control Panel and Remote Control
16 Wireless Remote Control
17 Ventilation
17 Air Direction
17 Additional Features
9 INSTALLATION
9 Electrical Data
10 Installation Overview
3 SAFETY INSTRUCTIONS
3 IMPORTANT SAFETY INSTRUCTIONS
8 PRODUCT OVERVIEW
8 Exterior Parts
8 Interior Parts
18 MAINTENANCE
18 Air Filter
19 TROUBLESHOOTING
19 Before Calling for Service
19 Normal Sounds You May Hear
22 WARRANTY
ENGLISH
3
SAFETY INSTRUCTIONS
SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always
read and follow all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or injure you and others.
All safety messages will follow the safety alert symbol and either the word WARNING or
CAUTION.
These words mean:
WARNING
You may be killed or seriously injured if you do not follow instructions.
CAUTION
You may be injured or cause damage to the product if you do not follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce
the chance of injury, and tell you what may happen if the instructions are not followed.
IMPORTANT SAFETY INSTRUCTIONS
WARNING
injury to persons when using this product, follow basic precautions,
including the following:
INSTALLATION
Before use, the appliance must be properly installed as described in this manual.
Contact the authorized service technician for repair or maintenance of this unit.
Contact the installer for installation of this unit.
The air conditioner is not intended for use by young children or invalids without supervision.
Young children should be supervised to ensure that they do not play with the air conditioner.
4
SAFETY INSTRUCTIONS
When the power cord is to be replaced, replacement work shall be performed by authorized
personnel only using only genuine replacement parts.
Installation work must be performed in accordance with the National Electric Code by qualied
and authorized personnel only.
Connect to a properly rated, protected, and sized power circuit to avoid electrical overload.
Always plug into a grounded outlet.
Do not under any circumstances, cut or remove the third (ground) prong from the power cord.
When installing or moving the appliance, be careful not to pinch, crush, or damage the power
cord.
Plug in the power plug properly.
Do not modify or extend the power cord.
Do not start/stop operation by plugging/unplugging the power cord.
If the cord/plug is damaged, have it replaced by an authorized service person using authorized
replacement parts.
Use a dedicated circuit.
Do not disassemble or modify the product.
Adhere to all industry recommended safety procedures including the use of long-sleeved gloves
and safety glasses.
Use care when unpacking and installing. The edges of the product may be sharp.
Disconnect the power cord or circuit breaker before installing or servicing the appliance.
Keep packaging materials out of the reach of children. These materials can pose a suffocation
risk to children.
Store and install the product where it will not be exposed to temperatures below freezing or
exposed to outdoor weather conditions.
Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any
other appliance.
OPERATION
Use this appliance only for its intended purpose.
Never attempt to operate this appliance if it is damaged, malfunctioning, partially disassembled,
or has missing or broken parts, including a damaged cord or plug.
Repair or immediately replace all power cords that have become frayed or otherwise damaged.
Do not use a cord that shows cracks or abrasion damage along its length or at either end.
Do not run cord under carpets or mats where it could be stepped on and damaged.
Keep the cord out from under heavy objects like tables or chairs.
Do not place the power cord near a heat source.
Do not use an adaptor or plug the product into a shared outlet.
Do not tamper with controls.
If you detect a strange sound, a chemical or burning smell, or smoke coming from the appliance,
unplug it immediately, and contact an LG Electronics Customer Information Center.
Never unplug the appliance by pulling on the power cord. Always grip the plug rmly and pull
straight out from the outlet.
Do not grasp the power cord or touch the appliance controls with wet hands.
ENGLISH
5
SAFETY INSTRUCTIONS
If water enters the product, turn off the power at the main circuit, then unplug the product and call
for service.
If the product has been submerged, contact an LG Electronics Customer Information Center for
instructions before resuming use.
Unplug the product when unused for long periods.
Unplug the product before cleaning.
In the event of a gas leak (propane gas, etc.) do not operate this or any other appliance. Open a
window or door to ventilate the area immediately.
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning the use of the appliance by a person responsible for
their safety.
The interior of the product must only be cleaned by an authorized service center or a dealer.
Do not use solvent-based detergent on the product. Doing so can cause corrosion or damage,
product failure, electrical shock, or re.
GROUNDING INSTRUCTIONS
The power cord of this appliance is equipped with a three-prong (grounding) plug. Use this with
a standard three-slot (grounding) wall power outlet to minimize the hazard of electric shock. The
customer should have the wall receptacle and circuit checked by a qualied electrician to make
sure the receptacle is properly grounded. DO NOT CUT OR REMOVE THE THIRD (GROUND)
PRONG FROM THE POWER PLUG.
- Situations when the appliance will be disconnected occasionally; Because of potential safety
hazards, we strongly discourage the use of an adapter plug. However, if you wish to use an
adapter, a TEMPORARY CONNECTION may be made. Use UL-listed adapter, available from
most local hardware stores.
The large slot in the adapter must be aligned with the large slot in the receptacle to assure a
proper polarity connection.
Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the
appliance unless the cover screw is metal, and not insulated, and the wall receptacle is grounded
through the house wiring. The customer should have the circuit checked by a qualied electrician
to make sure the receptacle is properly grounded.
Disconnect the power cord from the adapter, using one hand on each. Otherwise, the adapter
ground terminal might break. Do not use the appliance with a broken adapter plug.
- Situations when the appliance will be disconnected often; Do not use an adapter plug in these
situations. Unplugging the power cord frequently can lead to an eventual breakage of the
ground terminal. The wall power outlet should be replaced by a three-slot (grounding) outlet
instead.
6
SAFETY INSTRUCTIONS
CAUTION
To reduce the risk of minor or moderate injury to persons, malfunction, or
damage to the product or property when using this product, follow basic
precautions, including the following:
INSTALLATION
Take care when installing the product that exhaust or condensation does not damage nearby
property.
Follow installation instructions exactly to avoid excessive vibration or water leakage.
OPERATION
This appliance is not intended for use as a precision refrigeration system. Do not use it for special
purposes such as maintaining pets, food, precision machinery, or art objects.
When installing or moving the appliance, be careful not to pinch, crush, or damage the power
cord.
Make sure the air inlet and outlet are free from obstructions.
Use a soft cloth to clean the appliance. Do not use waxes, thinners, or harsh detergents.
Do not step on or place heavy objects on top of the appliance.
Do not drink water drained from the appliance.
are used simultaneously.
Remove the batteries if the remote control is not to be used for an extended period of time.
Never mix different types of batteries, or old and new batteries for the remote control.
f with clean water.
consult a doctor.
Do not recharge or disassemble the batteries.
MAINTENANCE
Never use strong cleaning agents or solvents when cleaning the air conditioner or spray water.
Use a smooth cloth.
Do not expose people, animals, or plants to the cold or hot wind from the air conditioner for
extended periods of time.
ENGLISH
7
SAFETY INSTRUCTIONS
REFRIGERANT (FOR R32 ONLY)
WARNING
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
The appliance shall be stored in a room without continuously operating ignition sources (for
example: open ames, an operating gas appliance or an operating electric heater).
Do not pierce or burn. Be aware that ammable refrigerants may not contain an odor.
CAUTION
This unit contains ammable refrigerant and has special safety precautions not normally
associated with older units. Please follow all precautions and advisories.
- Use caution while handling and prevent damage to unit. Do not put any holes into product for
any reason. This can cause damage to product and prevent unit from cooling.
- Maintenance and cleaning of unit should be performed by trained personnel. Failure to properly
clean unit can result in damage to the refrigeration system and or the electrical system.
- Make certain that all the air circulation/ventilation openings are free from obstruction.
- Service should only be performed by technicians properly trained and certied in the use of
ammable refrigerants. Any service performed by unauthorized servicers/individuals will void all
warranties.
- When storing the appliance, do not put in a room with any open ame appliances, such as gas
water heaters or furnaces. Also keep away from electric heaters. Damaged units should be
repaired before storage.
SAVE THESE INSTRUCTIONS
8
PRODUCT OVERVIEW
PRODUCT OVERVIEW
Exterior Parts Interior Parts
8
6
2
3
1
4
5
7
3
4
5
6
7
1
2
1
Evaporator
2
Air Guide
3
4
Brace
5
Compressor
6
Condenser
7
Base Pan
Power Cord
1
Control Panel
2
Remote Controller
3
Air Filter
4
5
6
Front Grille
7
8
Cabinet
Air Outlet
ENGLISH
9
INSTALLATION
INSTALLATION
Electrical Data
Power cord may include a current interrupter
device. TEST and RESET buttons are provided
on the plug case. The device should be tested on
TEST button
and then the RESET button. If the TEST button
does not trip or if the RESET button will not stay
engaged, discontinue use of the air conditioner
WARNING
This appliance should be installed in
accordance with the National Electrical
Code.
Use of extension cords could cause serious
injury or death.
- Do not use an extension cord with this
window air conditioner.
- Do not use surge protectors or multi-outlet
adapters with this window air conditioner.
Never push the TEST button during
operation. Doing so can damage the plug.
- Do not remove, modify, or immerse this
plug. If this device trips, the cause should
be corrected before further use.
CAUTION
The conductors inside this cord are
surrounded by shields, which monitor
leakage current. These shields are not
grounded. Periodically examine the cord
for any damage. Do not use this product
in the event the shields become exposed.
Avoid shock hazard. This unit cannot be
user-serviced. Do not open the tamper-
resistant sealed portion. All warranties and
performance will be voided. This unit is not
intended to be used as an ON/OFF switch.
Use Wall Receptacle Power Supply
Use 15 A, time
delay fuse or 15 A,
circuit breaker.
Standard 120 V, 3-wire
grounding receptacle rated
15 A / 120 VAC / 60 Hz
for 120 V
RESET
TEST
10
INSTALLATION
Installation Overview
Accessories
Type 'A' Screws
(14)
Type 'B' Screws
(3)
Type 'C' Screws
(5)
Carriage Bolt
(2)
Lock Nut
(2)
Tools Needed
Phillips-head
screwdriver
Flat-blade screwdriver Adjustable wrench Level
Tape measure Cutting knife Scissors Pencil
Heatproof foam (2)
(Adhesive backed)
Right curtain
panel
Left curtain
panel
Foam strip
(Non-adhesive)
Foam-PE (2)
(Adhesive backed)
Lower panel
guide (2)
Window locking
bracket
Sill bracket (2)
ENGLISH
11
INSTALLATION
How to Install the Unit
Window Requirements
This unit is designed for installation in standard
double hung windows with actual opening
widths from 27" to 39".
The top and bottom window sash must open
sufficiently to allow a clear vertical opening of
16" from the bottom of the upper sash to the
window stool.
NOTE
wood, masonry, or metal.
All supporting parts should be secured to firm
Fence
Awning
Heat
radiation
Cooled air
27" to 39"
Offset
Interior Wall
Exterior
Sill
Stool
(686mm to 991mm)
(Without frame curtain)
1/2 to 1/4"
(12.7mm to 31.8mm)
23 5/8"(600mm) min
About 1/2" (12.7mm)
Over 20" (508mm)
30"~60"
(762mm~1524mm)
CAUTION
All side louvers of the cabinet must remain
exposed to the outside of the structure.
16"
(With frame curtain)
(406mm)
min
Preparation of Cabinet
1
Remove 4 screws which fasten the cabinet
at both sides and at the back. (Keep the
screws for later use.)
1
To prevent vibration and noise, make sure
the unit is installed securely and firmly.
4
Install the unit slightly tilted so the back is
slightly lower than the front (about 1/2").
This will force condensed water to flow to
the outside.
5
Install the unit with the bottom between
30" ~ 60" above the floor level.
2
Install the unit where the sunlight dose not
shine directly on the unit.
3
The outside of the cabinet must extend out-
ward for at least 12" and there should be no
obstacles, such as a fence or wall, within 20"
from the back of the cabinet because it will
prevent heat radiation of the condenser.
Restriction of outside air will greatly reduce
the cooling efficiency of the air conditioner.
Shipping
Screws
CAUTION
The unit is heavy. To prevent injury, use
proper lifting techniques when pulling unit
forward from cabinet. Obtain assistance
from another person if possible.
3
Cut the window sash seals (Foam-PE)
to the proper length. Peel off the backing
and attach the adhesive-backed foam to
the underside of the window sash and the
bottom of the window frame.
Foam-PE
(Adhesive backed)
2
Slide the unit from the cabinet by gripping
the base pan handle and pulling forward
while bracing the cabinet.
12
INSTALLATION
Cabinet Installation
1
Open the window. Mark a line on the center
of the inside sill.
Carefully place the cabinet in the window and
align the center hole on the cabinet bottom
front with the bracket using a carriage bolt
and a lock nut.
2
Pull the bottom window sash down behind
the upper guide until they meet.
Center Line
Outside Sill
Inside Sill
1 ¼" max.
Center Hole
Inside Sill
Upper Guide
Window Sash
4
Insert the lower curtain panel guides into
the bottom of the cabinet. Insert the guides
cabinet.
5
Upper Panel Guide
Right Curtain Panel
Left Curtain Panel
Lower Panel
Guide
Insert the top and bottom rails of the curtain
panels into the upper and lower panel
guides.
CAUTION
The lower panel guides are easily broken.
Be careful with them when installing the
cabinet.
6
Fasten the curtain panels to the unit with 8
type A screws.
Do not pull the window sash down so
tightly that the movement of the curtain
panels is restricted.
NOTE
ENGLISH
13
INSTALLATION
4
Use 2 type A screws to attach a sill support
to the cabinet track holes on one side. Use
the cabinet track holes that will place the sill
support nearest to the outer edge of the sill.
Repeat with the second sill support on the
opposite side of the cabinet.
5
Install the cabinet with a slight tilt (about ½”)
downward on the outside.
Use the bolt and nut to adjust the tilt of the
cabinet.
CAUTION
Do not drill a hole in the bottom pan.
The product is designed to operate with
approximately ½” of water in the bottom
pan. There is no need to add water if the
pan is dry.
8
Use a screwdriver or power drill to attach
the curtain panels to the window sashes
by driving type C screws into the sashes
through the cabinet holes shown in the
Screws (Type A)
Indoor
Outdoor
about
½”
Cabinet
7
Pull each curtain panel out until it meets the
window sash track. Pull the bottom window
sash down behind the upper panel guide
until they meet.
Front Angle
Sash Track
Upper Panel
Guide
Inside Window Sill
NOTE
Do not pull the window sash down so
tightly that the movement of the curtain
panels is restricted.
6
Attach the cabinet to the inside sill by
driving 3 type B screws through the cabinet
and into the sill.
Sash Track
Front Angle
NOTE
Install the cabinet with a very slight
downward tilt toward the outside.
CAUTION
Do not drill a hole in the bottom pan.
The product is designed to operate with
approximately ½” of water in the bottom
pan.
3
Loosely assemble each sill support.
Sill Support
Nut
Bolt
If the distance to the outer window sill is
not that deep, you may not need the bolt
and nut.
NOTE
14
INSTALLATION
10
Cut the non-adhesive foam strip to the
proper length and insert it between the
upper window sash and the lower window
sash.
Foam Strip
(Non-adhesive)
11
Attach the window locking bracket with a
type C screw.
Window Locking Bracket
12
Before installing the front grille, pull out the
vent control lever located above the unit
14
Connect the housing.
15
Attach the front grille to the cabinet by
insertingthe tabs the grille into the slots on
the front the cabinet.Push the grille in until
it snaps into place.
13
NOTE
Guide the lever carefully through the grille
as you push it in.
NOTE
NOTE
See the 'Electrical Data' section for
information on attaching the power cord
to an electrical outlet.
16
Take out the air filter and secure it with 2
type A screws through the front grille.
9
With the aid of an assistant, slide the
unit into the cabinet. Reinstall the screws
removed from the cabinet sides in step 1.
CAUTION
The unit is heavy. Use an assistant to help lift the
Hold the unit firmly in place until the window
unit and set it in place. Lifting and maneuvering
the unit by yourself could result in injury.
frameis lowered to meet the top surface of the
unit directly behind the upper guide. If the unit
falls from the window, it could cause personal
injury orproperty damage.
control knobs, as shown.
Cut the adhesive-backed heatproof foam
to match the size of the curtain panels.
Remove the backing from the heatproof
foam and attach it to the curtain panels.
Heatproof Foam
Heatproof foam improves the cooling
capability of the air conditioner.
ENGLISH
15
OPERATION
.
OPERATION
Control Panel and Remote Control
Remote Control
1
Power
2
Fan Speed
Use to set the fan speed to Low (F1), MED
(F2), High (F3).
3
ON/OFF Timer
Delay ON - When the air conditioner is off,
it can be set to automatically turn on from
1 to 24 hours at its previous mode and fan
settings.
Delay OFF - When the air conditioner is on,
it can be set to automatically turn on from
1 to 24 hours.
NOTE
Each press of the Timer button advances
the timer by 1 hour. After the last press
the display returns to the temperature
setting.
Operation starts when this buttom is pressed
and stops when you press the buttom again.
Cool
Fan - Fan circulates air but the compressor
does not run. Use the FAN button to set
the desired fan speed.
Dry - Dry mode is used to remove humidity
from the room without additional cooling.
Once the set temperature is reached, the
compressor and circulation fan turns off.
Fan speed is pre-set and cannot be
adjusted.
1
4
2
5
3
- Compressor runs and cools the
room. Use the and FAN buttons to
set the desired temperature and circulation
fan speed.
Energy Saver - The fan stops when the
compressor stops cooling. Approximately
every 3 minutes the fan will turn on and
check the room air temperature if cooling
is needed.
4 3 2
1
5
7
6
4
Operation Mode Selector
Push the Mode button to rotate between
Energy Saver / Cool / Fan / Dry.
16
OPERATION
5
Temperature Control
The thermostat monitors room temperature
to maintain the desired temperature. The
thermostat can be set between 60 °F–86 °F
(16 °C–30 °C). Press
or arrows to
increase or decrease temperature setting.
6
Remote Control Sensor
Clean Filter
The Clean Filter LED lights up to notify you
that the lter needs to be cleaned. After
cleaning the lter, press T
emp
and
together on the control panel to turn off the
Clean Filter light.
NOTE
The lter reset must be done using the
control panel, not the remote control.
This feature is a reminder to clean the air
lter for more efcient operation. The LED
light turns on after 250 hours of operation.
7
NOTE
Auto Restart: If the air conditioner turns off due
to a power outage, it will restart automatically
once the power is restored, with the same
settings as were set before the unit turned off.
Energy Saver: The unit defaults to the Energy
Saver mode each time the unit is switched on
except in Fan mode or when power is restored
after an electrical power outage.
The remote control will not function properly if
the AC infrared sensor is exposed to direct light
or if there are obstacles between the remote
controller and the air conditioner
.
Wireless Remote Control
Inserting Battery
1
Remove the cover from the back of the
remote controller.
2
Insert one battery.
3
Reattach the cover.
NOTE
Be sure that the (+) and (-) directions
are correct.
Be sure that the battery is new.
Do not use a rechargeable battery.
In order to prevent discharge, remove the
battery from the remote control if the air
conditioner is not going to be used for an
extended period of time.
Keep the remote control away from
extremely hot or humid places.
To maintain optimal operation of the remote
control, the remote sensor should not be
exposed to direct sunlight.
Close Open
Air Direction
ENGLISH
17
OPERATION
Ventilation
Push the ventilation lever in to the closed position
to maintain the best cooling performance. Pull
the ventilation lever out to open the vent and
draw fresh air into the room.
of the air conditioner’s louvers.
Direction
levers of the vertical louvers to the left or right.
Direction
up or down.
NOTE
When the weather is extremely hot, the unit
may turn off automatically to protect the
compressor.
Additional Features
Slinger Fan
This air conditioner is equipped with a slinger
fan. (See drawing.)
The fan’s outer ring picks up the condensed
water from the base pan if the water level gets
high enough. The water is then picked up by the
fan and expelled through the condenser, making
Ring
18
MAINTENANCE
2
40 °C (104 °F).
3
Gently shake the excess water from the
Cleaning the Air Conditioner
Wipe the front grille and inlet grille with a cloth
dampened in a mild detergent solution.
Wash the cabinet with mild soap or detergent
and lukewarm water, then polish using liquid
appliance wax.
NOTE
condenser coils (outside of unit) should be
checked periodically and cleaned if clogged
with soot or dirt from outside air.
MAINTENANCE
For repair and maintenance, contact an
Authorized Service Center. See the warranty
page for details or call 1-888-LG-CANADA
(542 2623).
Have your model number and serial number
available. They should be written on page 23
of this manual.
WARNING
Before cleaning or performing maintenance,
disconnect the power supply and wait until
the fan stops.
Air Filter
if cleaning is necessary. Trapped particles in the
cooling capacity and causing an accumulation of
frost on the evaporator.
Cleaning the Air Filter
1
ENGLISH
19
TROUBLESHOOTING
Before Calling for Service
The appliance is equipped with an automatic error-monitoring system to detect and diagnose problems
at an early stage. If the appliance does not function properly or does not function at all, check the
following before you call for service.
Normal Sounds You May Hear
1
High Pitched Chatter
2
Sound of Rushing Air
At the front of the unit, you may hear the sound of rushing air being moved by the fan.
3
Gurgle/Hiss
Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during
normal operation.
4
Vibration
Unit may vibrate and make noise because of poor wall or window construction or incorrect
installation.
5
Pinging or Swishing
Droplets of water hitting condenser during normal operation may cause pinging or swishing
sounds.
1
2
3
4
5
TROUBLESHOOTING
20
Problem Possible Cause Solutions
Air conditioner
does not start.
The air conditioner is unplugged.
Make sure the air conditioner plug
is pushed completely into the outlet.
The fuse is blown/circuit breaker
is tripped.
Check the house fuse/circuit
breaker box and replace the fuse or
reset the breaker.
Power failure.
If power failure occurs, turn the
mode control to off. When power is
restored, wait 3 minutes to restart
the air conditioner to prevent
tripping of the compressor overload.
The current interrupter device is
tripped.
Press the RESET button located
on the power cord plug. If the
RESET button will not stay
engaged, discontinue use of the air
conditioner and contact a qualied
service technician.
Air conditioner
does not cool as it
should.
Airow is restricted.
Make sure there are no curtains,
blinds, or furniture blocking the front
of the air conditioner.
The temp control may not be set
correctly.
Set the desired temperature to
a level lower than the current
temperature.
The air lter is dirty.
Clean the lter at least every 2
weeks. See the 'MAINTENANCE'
section.
The room may have been hot.
When the air conditioner is rst
turned on, you need to allow time
for the room to cool down.
Cold air is escaping.
Check for open furnace oor
registers and cold air returns.
Cooling coils have iced up.
See 'Air conditioner freezing up'
below.
Air conditioner
freezing up.
The cooling coils are iced over.
Ice may block the air ow and
obstruct the air conditioner from
properly cooling the room. Set the
mode control at High Fan or High
Cool.
Water drips
outside.
Hot, humid weather. This is normal.
TROUBLESHOOTING
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52

LG LW1016ER Le manuel du propriétaire

Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues