10
aTM INsTaLLaTION fOR aC-
CEssIbILITy
1. This document supercedes all
other information provided by
Triton for ATM installation for
accessibility.
2. Information provided in this man-
ual is based on federal guidelines
(ADA Accessibility Guidelines
for Buildings and Facilities –
ADAAG), as amended through
January 1998. You should verify
it has not been amended. States
may also have accessibility codes.
These codes may be more restric-
tive than the federal guidelines.
Please verify this with the state
where the ATM is to be installed
prior to installation. For state
contact information, you may
call the ADA information line at
1-800-514-0301.
3. For countries other than the US,
please use the guidelines for ac-
cessibility for that country.
4. A complete copy of the ADAAG
referred to here can be found at
http://www.access-board.gov.
Included in this document is
the section of the ADAAG spe-
cically for ATMs. For additional
information on oor surfaces and
other ADAAG requirements,
please see the complete specica-
tion.
4.34 Automated Teller Machines.
4.34.1 General. Each automated
teller machine required to be
accessible by 4.1.3 (Accessible
Buildings:New Construction)
shall be on an accessible route
and shall comply with 4.34 (Au-
tomated Teller Machines).
4.34.2 Clear Floor Space. The
automated teller machine shall be
located so that clear oor space
complying with 4.2.4 (Clear
Floor or Ground Space for
Wheelchairs) is provided to al-
low a person using a wheelchair
to make a forward approach, a
parallel approach, or both to the
machine.
4.34.3 Reach Ranges.
(1) Forward Approach Only. If
only a forward approach is possible,
operable parts of all controls shall be
placed within the forward reach range
specied in 4.2.5 (Forward Reach).
(2) Parallel Approach Only. If only
a parallel approach is possible, oper-
able parts of controls shall be placed
as follows:
(a) Reach Depth Not More Than
10 inches (255 mm). Where the reach
depth to the operable parts of all con-
trols as measured from the vertical
plane perpendicular to the edge of the
unobstructed clear oor space at the
farthest protrusion of the automated
teller machine or surround is not
more than 10 inches (255 mm), the
maximum height above the nished
oor or grade shall be 54 inches (1370
mm).
RL5000
XP
INsTaLLaTION GUIDE