Avent SCF398/11 Manuel utilisateur

Catégorie
Tire-lait
Taper
Manuel utilisateur

Ce manuel convient également à

Single/Double
electric breast pump
Premium
SCF398, SCF396
www.philips.com/mybreastpump
Foldout left only
CB
A
A1
A2
A3
C5
C3 C4
C2
C1
A4
B1
B2
B3
B4
B5
B6
A5
English
Contents
Introduction __________________________________________________________________________________________ 5
General description __________________________________________________________________________________ 6
Intended use _________________________________________________________________________________________ 6
Important safety information ________________________________________________________________________ 6
Before first use _______________________________________________________________________________________ 10
Cleaning and disinfecting ____________________________________________________________________________ 10
Using the breast pump _______________________________________________________________________________ 13
Feeding breast milk with the bottle__________________________________________________________________ 20
Compatibility _________________________________________________________________________________________ 22
Ordering accessories _________________________________________________________________________________ 22
Recycling______________________________________________________________________________________________ 22
Battery removal instructions _________________________________________________________________________ 23
Warranty and support ________________________________________________________________________________ 24
Troubleshooting ______________________________________________________________________________________ 24
Supplemental information __________________________________________________________________________ 26
Storage conditions ___________________________________________________________________________________ 27
Electromagnetic fields (EMF) ________________________________________________________________________ 27
Technical information ________________________________________________________________________________ 27
Explanation of symbols ______________________________________________________________________________ 28
Introduction
Congratulations on your purchase and welcome to Philips Avent! To fully benefit from the support
that Philips Avent offers, register your breast pump at www.philips.com/welcome.
The Philips Avent single/double electric breast pump Premium is inspired by babies and their natural
suction movement. The soft silicone cushion stimulates the nipple with gentle massaging movements,
helping you to express milk comfortably and effectively. The combination of suction and nipple
stimulation triggers fast milk flow. The no-lean-forward design enables you to sit in a relaxed, upright
position while expressing.
Healthcare professionals and the World Health Organization recommend breast milk as the primary
source of nutrition during the first year of life, combined with solid food after the first 6 months. This is
because your breast milk is specially adapted to your baby’s needs and helps to protect your baby
against infection and allergies. To breastfeed longer, you can express and store your milk so that your
baby can still enjoy the benefits of it, even if you cannot be there to provide it yourself. As the pump is
compact, quiet and discrete to use, you can take it with you anywhere, allowing you to express milk at
your own convenience and to maintain your milk supply.
If breastfeeding goes well, it is advisable (unless recommended otherwise by your healthcare
professional) to wait until your milk supply and breastfeeding schedule are established (normally at
least 2 to 4 weeks after giving birth) before you start expressing.
5
English
English
General description
Note: The numbers mentioned below refer to the numbers on the figure of the front foldout page
of this user manual.
Note: The double breast pump comes with two pieces of the items shown in Figures B and C.
Product description (Fig. A)
A1 Motor unit
A2 Breast pump kit
A3 Bottle
A4 Adapter
A5 Double breast pump
Breast pump kit (Fig. B)
B1 Silicone tube and cap
B2 Silicone diaphragm
B3 Pump body
B4 Cover
B5 Cushion
B6 White valve
Philips Avent Natural Bottle (Fig. C)
C1 Bottle cap
C2 Screw ring
C3 Teat
C4 Sealing disc
C5 Bottle
Accessories
There are multiple versions of this breast pump package, which all come with a different combination
of the following Philips Avent accessories:
-
Breast pads
-
Travel bag
-
Insulation pouch
-
Cleaning brush
-
Storage cups with adapter*
-
Breast milk storage bags*
-
Natural bottles
-
Breast pump belt*
* For these accessories, a separate user manual is provided.
Intended use
The Philips Avent single/double electric breast pump Premium is intended to express and collect milk
from the breast of a lactating woman.
The device is intended for a single user.
Important safety information
Read this user manual carefully before you use the breast pump and save it for future reference.
This user manual can also be found online on the Philips Avent website: www.philips.com/avent.
6
English
Warnings
-
Never use the breast pump while you are pregnant, as pumping
can induce labor.
Warnings to avoid choking, strangulation and injury:
-
This breast pump is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge. Such persons can only use this
breast pump if they are supervised by or have received proper
instruction concerning use of the appliance by a person
responsible for their safety.
-
Do not allow children or pets to play with the motor unit, the
adapter, packaging materials or accessories.
-
Always unplug the breast pump after use and when fully charged.
Warnings to prevent transmitting infectious diseases:
-
If you are a mother who is infected with Hepatitis B, Hepatitis C or
Human Immunodeficiency Virus (HIV), expressing breast milk will
not reduce or remove the risk of transmitting the virus to your
baby through your breast milk.
Warnings to avoid electric shock:
-
Inspect the breast pump, including the adapter, for signs of
damage before each use. Do not use the breast pump if the
adapter or plug is damaged, if it does not work properly or if it has
been dropped or submerged in water.
-
Only use the adapter (S009AHz050yyyy) provided with this
breast pump.
-
Always ensure that it is easy to disconnect the device from the
mains in case of malfunction.
Warnings to avoid contamination and to ensure hygiene:
-
For hygienic reasons, the breast pump is only intended for
repeated use by a single user.
7
English
English
-
Clean and disinfect all parts before first use and after each use.
-
Do not use antibacterial or abrasive cleaning agents to clean the
breast pump parts as this may cause damage.
-
Wash your hands thoroughly with soap and water before you
touch breast pump parts and breasts to prevent contamination.
Avoid touching the inside of containers or lids.
Warnings to avoid breast and nipple problems including pain:
-
Do not use the breast pump if the silicone diaphragm appears to
be damaged or broken. See chapter ‘Ordering accessories’ for
information on how to obtain replacement parts.
-
Only use accessories and parts recommended by Philips Avent.
-
No modification of the breast pump is allowed. If you do so, your
warranty becomes invalid.
-
Never use the breast pump while you are sleepy or drowsy to
avoid lack of attention during use.
-
Always switch off the breast pump before you remove the pump
body from your breast, in order to release the vacuum.
-
If the vacuum is uncomfortable or causes pain, switch off and
remove the breast pump from your breast.
-
Do not continue pumping for more than five minutes at a time if
you do not succeed in expressing any milk. Try to express at
another time during the day.
-
If the process becomes very uncomfortable or painful, stop using
the pump and consult your healthcare professional.
Warnings to prevent damage and malfunction of the breast pump:
-
Portable radio frequency (RF) communications equipment
(including mobile phones and peripherals such as antenna cables
and external antennas) should not be used closer than 30cm
(12in) to any part of the breast pump, including adapter. This
could have negative effect on the performance of the breast
pump.
8
English
-
Use of this equipment adjacent to or stacked with other
equipment should be avoided because it could result in improper
operation.
Battery safety instructions
-
Only use thisproduct for its intended purpose as described in this
user manual. Any misuse can cause electric shock, burns, fire and
other unexpected hazards.
-
To charge the battery, only use the detachable supply unit
provided with the product. Do not use an extension cord.
-
Charge, use and store the product at the temperature ranges
indicated in the technical specifications table in this user manual.
-
Always unplug the product when it is fully charged.
-
Do not burn products and their batteries and do not expose them
to direct sunlight or to high temperatures (e.g. in hot cars or near
hot stoves). Batteries may explode if overheated.
-
If the product becomes hot, changes color, gives off an abnormal
smell or if charging takes much longer than usual, stop using and
charging it.
-
Do not place products and their batteries in microwave ovens or
on induction cookers.
-
This product contains a rechargeable battery that is non-
replaceable. Do not open the product to replace the rechargeable
battery.
Cautions
Cautions to prevent damage to and malfunctioning of the breast
pump:
-
Prevent the adapter and motor unit from coming into contact with
water.
-
Never put the motor unit or the adapter in water or in a
dishwasher, as this causes permanent damage to these parts.
9
English
English
-
Keep the adapter and the silicone tubes away from heated
surfaces to avoid overheating and deformation of these parts.
Before first use
Disassemble, clean and disinfect all parts that come into contact with breast milk before you use the
breast pump for the first time and after every use.
Fully charge the device before you use it for the first time or after a long period of non-use.
Cleaning and disinfecting
Overview
Clean and disinfect the parts that come into contact with the breast and breast milk as described
below:
When How
Clean and disinfect before first use
and after every use.
Disassemble all parts and then
clean them as described in chapter
'Cleaning' and disinfect them as
described in chapter 'Disinfecting'.
The following parts do not come into contact with the breast and breast milk; clean them as described
below:
When How
Clean when needed. Wipe with a clean, damp cloth with
water and mild detergent.
10
English
Step 1: Disassembling
Make sure that you remove the white valve from the breast pump.
Step 2: Cleaning
The parts that come in contact with milk can be cleaned manually or in the dishwasher.
Warning: Do not use antibacterial or abrasive cleaning agents to clean the breast
pump parts as this may cause damage.
Caution: Never put the motor unit or the adapter in water or in a dishwasher, as this
causes permanent damage to these parts.
Caution: Be careful when you remove and clean the white valve. If it gets damaged,
your breast pump does not function properly. To remove the white valve, gently pull at
the ribbed tab on the side of the valve. To clean the white valve, rub it gently between
your fingers in warm water with some dishwashing liquid. Do not insert objects into the
white valve, as this may cause damage.
Step 2A: Manual cleaning
Supplies needed:
-
Mild dishwashing liquid
-
Drinking-quality water
-
Soft, clean brush
-
Clean tea towel or drying rack
-
Clean sink or bowl
1. Rinse all parts under a
running
tap with
lukewarm water.
5 min.
2. Soak all parts for
5minutes
in warm water
with some mild
dishwashing liquid.
3. Clean all parts with a
cleaning
brush.
4. Thoroughly rinse all
parts
under a running
tap with drinking-quality
water.
11
English
English
5. Leave all parts to air-
dry on a clean tea towel
or drying rack.
Step 2B: Cleaning in the dishwasher
Supplies needed:
-
Mild dishwashing liquid or a dishwashing tablet
-
Drinking-quality water
Note: Food colorings may discolor parts.
1. Place all parts on the
top rack of the
dishwasher.
2. Put dishwashing liquid
or a tablet in the
machine and run a
standard program.
3. Leave all parts to air-
dry on a clean tea towel
or drying rack.
Step 3: Disinfecting
Supplies needed:
-
A household pot
-
Drinking-quality water
Caution: During disinfection with boiling water, prevent the bottle or other parts from
touching the side of the pan. This can cause irreversible product deformation or damage
that Philips cannot be held liable for.
12
English
5 min.
1. Fill a household pot
with enough water to
cover all parts and place
all parts in the pot. Let
the water boil for
5minutes. Make sure
the parts do not touch
the side of the pot.
2. Allow the water to
cool down.
3. Gently remove the
parts from the water.
Place the parts on a
clean surface/tea towel
or drying rack to air-dry.
4. Store the dry items in
a clean, dry and covered
container.
Using the breast pump
Cushion size
The Philips Avent single/double electric breast pump Premium has a soft, active cushion. It gently
stimulates your nipple to trigger milk flow. The cushion is made of flexible silicone, that adapts to up
to 99.98% of women, fitting nipple sizes up to 30mm.
Charging the breast pump
Fully charge the battery before you use the breast pump for the first time and when the battery is low.
Fully charging the battery takes up to 4hours.
1. Switch off the device. 2. Insert the adapter into
the wall socket and
insert the small plug at
the other end into the
motor unit.
3. The battery is
charging.
4. When the battery is
fully charged, remove
the adapter from the
wall socket and pull the
small plug out of the
motor unit.
13
English
English
Battery indicator light description
All lights are steady
on.
The battery is fully
charged.
First light is steady
on.
The battery is
charged sufficiently
for one session.*
First light flashes
slowly.
The battery is low,
charging needed.
First light flashes
quickly.
The battery is very
low, the device will
soon stop
operating.
Battery lights light
up one by one and
go out all together.
The battery is
charging.
* One session is the equivalent of 20 minutes (double electric breast pump) or 30 minutes (single
electric
breast pump).
Assembling the breast pump
Make sure you have cleaned and disinfected the parts of the breast pump that come into contact with
milk.
Warning: Be careful, when you have disinfected the breast pump parts by boiling
them, they can be very hot. To prevent burns, only start assembling the breast pump
when disinfected parts have cooled down.
Warning: Wash your hands thoroughly with soap and water before you touch breast
pump parts and breasts to prevent contamination. Avoid touching the inside of
containers or lids.
Check the breast pump kit parts for wear or damage before use and replace them if necessary.
Note: Correct placement of the cushion, silicone diaphragm and silicone tube is essential for the
breast pump to form a proper vacuum.
1. Wash your hands
thoroughly with soap
and water.
2. Push the white valve
in the pump body as far
as possible.
3. Screw the pump body
onto the bottle.
4. Place the cushion in
the pump body and
make sure that the rim
covers the pump body.
14
English
4A Push the inner part of
the cushion into the
funnel against the line
(indicated with an
arrow).
5. Place the silicone
diaphragm in the pump
body.
5A Make sure that the
silicone diaphragm fits
securely around the rim
by pressing it down with
your thumbs.
6. Attach the silicone
tube and cap onto the
silicone diaphragm.
Push down the cap until
it is securely in place.
7. Connect the tube(s) to
the motor unit.
8A. When the breast
pump is charged, you
can use it cordless. Press
and hold the on/off
button until the device
switches on.
8B. You can also use the
breast pump connected
to the wall socket. If the
battery is low, insert the
adapter into the wall
socket and insert the
small plug at the other
end into the motor unit.
9. The breast pump is
now ready for use.
Note: You can place
the cover over the
cushion to keep the
breast pump clean while
you are preparing for
expressing.
15
English
English
Motor unit part description
7
1 3 5
4 6
8
2
1 USB power inlet
2 On/off button with
pause/play function
3 Mode selection button
4 'Level down' button
5 'Level up' button
6 LED display
7 Tubing port for single breast
pump
8 Tubing ports for double
breast pump
LED display description
1
2
3
4
1 Battery indicator lights
2 Timer (minutes) and vacuum
level indication
3 Expression icon
4 Stimulation icon
Explanation of modes
The breast pump has two modes. Below you find an explanation of these modes.
Mode icons Mode Explanation No. of suction levels
Stimulation mode Mode to stimulate the breast to
start up the milk flow.
8 suction levels
Expression mode Mode for efficient milk removal
after milk has started flowing. After
90 sec. of stimulation, the device
automatically switches to the
expression mode.
16 suction levels
16
English
The number on the display shows the running
time in minutes.
When you change the suction level, the display
shows the selected suction level for a few
seconds and then shows the running time again.
Pumping instructions
Warning: Before you remove the pump body from your breast, always switch off the
breast pump to release the vacuum.
Warning: Do not continue pumping for more than 5 minutes at a time if you do not
succeed in expressing any milk. Try to express at another time during the day.
Warning: If the process becomes very uncomfortable or painful, stop using the pump
and consult your healthcare professional.
Note: If you regularly express more than 125ml/4floz per session, you can purchase and use a
260ml/9floz Philips Avent Natural bottle to prevent overfilling and spillage.
Note: The breast pump can be used cordless if it is sufficiently charged, but you can also use it
connected to the wall socket.
1. Wash your hands
thoroughly with soap
and water and make
sure that your breast is
clean.
2. Place the breast pump
kit onto your breast.
Make sure that you
center your nipple.
3. Press and hold the
on/off button until the
device switches on. The
indicator lights go on to
indicate that the device
is in stimulation mode.
4. The breast pump
starts in stimulation
mode and slowly
increases its vacuum to
the last used stimulation
suction level (or level 5
when used for the first
time).
17
English
English
5. The display shows the
running time.
6. Use the 'level up' and
'level down' buttons to
change the suction level
to your preference.
7. After 90 seconds the
breast pump will switch
smoothly to expression
mode and slowly
increase its vacuum to
the last used expression
suction level (or level 11
when used for the first
time).
8. If your milk starts
flowing earlier or if you
want to switch from
expression to
stimulation mode, you
can switch modes with
the mode selection
button.
9. Briefly press the
on/off button if you
want to pause. To
continue, briefly press
the on/off button again.
10. Press and hold the
on/off button to switch
off.
Tip: For optimal expression, choose the highest setting that still feels comfortable. This setting may
differ across different sessions.
Tip: You can use the double breast pump as a single breast pump by connecting only the tube of
one pump kit to the motor unit.
18
English
After use
1. Unscrew the bottle. 2A. To store the breast
milk: close the bottle
with the sealing disc and
screw ring.
1
2
2B. To prepare the bottle
for feeding your baby:
place a teat in a screw
ring and screw the
assembled screw ring
onto the bottle. Seal the
teat with the bottle cap
(see 'Assembling the
bottle').
3. Unplug the adapter
from the wall socket and
motor unit.
4. Remove the silicone
tube and cap from the
breast pump kit.
5. Disassemble and
clean all parts that have
been in contact with
breast milk (see
'Cleaning and
disinfecting').
6. For easy storage, wrap
the silicone tube around
the motor unit and clip
the cap onto the tube.
Warning: Refrigerate or freeze expressed milk immediately or keep it at a temperature
of 16-29 °C (60-85 °F) for a maximum of 4 hours before you feed your baby.
For more information about the breast pump and tips for expressing milk, visit
www.philips.com/avent.
Storing breast milk
Below you find guidelines for storing breast milk:
Storage location Temperature Max. storage duration
Room 16-29⁰C (60-85⁰F) 4 hours
Refrigerator 4
C (39⁰F)
4 days
Freezer < -4⁰C (25⁰F) 6-12 months
Warning: Never refreeze thawed breast milk to avoid a decrease in milk quality.
19
English
English
Warning: Never add fresh breast milk to frozen breast milk to avoid a decrease in milk
quality and unintended thawing of the frozen milk.
Feeding breast milk with the bottle
Warning: For your child's safety and health
-
Always use this bottle with adult supervision.
-
Never use feeding teats as a soother, to prevent a choking hazard.
-
Continuous and prolonged sucking of fluids will cause tooth decay.
-
Always check the food temperature before you feed your baby.
-
Keep all components not in use out of the reach of children.
-
Keep the bottle cap away from children to avoid suffocation.
-
Do not allow children to play with small parts or walk/run while using bottles.
-
Inspect all parts before use and pull the feeding teat in all directions. Throw away any part at the
first signs of damage or weakness.
-
Always discard any breast milk that is left over at the end of a feed.
Caution: To avoid damage to the bottle
-
Do not place in a heated oven, plastic can melt.
-
Plastic material properties may be affected by disinfection and high temperatures. This can affect
the fit of the bottle cap.
-
Do not leave a feeding teat in direct sunlight or heat, or leave in disinfectant for longer than
recommended because this may damage the product.
Before using the bottle
-
Inspect the bottle and feeding teat before each use and pull the feeding teat in all directions to
prevent a choking hazard. Throw away at the first signs of damage or weakness.
-
Clean and disinfect the bottle before first use and after every use.
20
English
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138

Avent SCF398/11 Manuel utilisateur

Catégorie
Tire-lait
Taper
Manuel utilisateur
Ce manuel convient également à