Episode ESA-70V2CH-500W Guide d'installation

Catégorie
Matériel musical
Taper
Guide d'installation

Ce manuel convient également à

INSTALLATION MANUAL
ESA-70V2CH-150W
ESA-70V2CH-300W
ESA-70V2CH-500W
PROT -30 -20 -10 CLIP
1
2
ECA-70IPAMP-2D-150
ETHERNET
12V TRIGGER
IN
OUT
LOOP
OUT
CH1
CH2
UNBALANCED
INPUTS
BALANCED INPUTS
CH3
CH4
LEVEL
CH1 CH2
SPEAKER OUT
CH1 CH2
+
_ _
+
R
UTILISER UN FUSIBLE DE RECHANGE
DE ME M E TYP E ET CA LI B R E.
ATTENTION:
FOR CONTINUED PROTECTION AGAINST
RISK OF FIRE, REPLACE O NLY WITH
SAM TYPE FUSE AND RATING.
CAUTION:
E
100/120V~60Hz 3.15A
T3.15A L 250V
220/240V~50Hz 1.6A
T1.6A L 250V
S
IR RS232
TxRx
In1
In2
DRY
CONTACT
G G
+
_
+
_
G G
page | 2
IMPORTANT SAFETY INSTRUCTIONS
WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or
moisture.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s
instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other
apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug
has two blades with one wider than the other. A grounding-type plug has two blades and
a third grounding prong. The wide blade or the third prong are provided for your safety.
If the provided plug does not fit into your outlet, consult an electrician for replacement of
the obsolete outlet.
10. Protect the power cord from being walked on or pinched, particularly at plugs, convenience
receptacles, and the point where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer,
or sold with the apparatus. When a cart is used, use caution when moving the
cart/apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long
periods of time. Refer all servicing to qualified service personnel. Servicing is required
when the apparatus has been damaged in any way, such as power-supply cord or plug is
damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus
has been exposed to rain or moisture, does not operate normally, or has been dropped.
14. This product employs a Class I (or grounded) construction and shall be connected to a
mains socket outlet with a protective earthed (or ground) connection.
15. DO NOT EXPOSE THIS EQUIPMENT TO DRIPPING OR SPLASHING AND ENSURE THAT NO
OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES, ARE PLACED ON THE EQUIPMENT.
16. TO COMPLETELY DISCONNECT THIS EQUIPMENT FROM THE AC MAINS, DISCONNECT THE
POWER SUPPLY CORD PLUG FROM THE AC RECEPTACLE.
17. THE MAIN PLUG OF THE POWER SUPPLY CORD SHALL REMAIN READILY OPERABLE.
18. CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER. NO USER
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
ATTENTION ! RISQUE DE CHOC ! ÉLECTRIQUE PAS OUVRIR !
CAUTION
Risk of Electrical Shock!
DO NOT OPEN!
!
The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the
user to the presence of uninsulated dangerous voltage within the product’s enclosure that may be
of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to the presence
of important operating and maintenance (servicing) instructions in the literature accompanying
the appliance.
page | 3
© 2019 Episode®
CONSIGNES DE SÉCURITÉ IMPORTANTES
Avertissement: Pour réduire le risque d’ incendie ou un choc électrique, ne pas exposer cet
appareil à la pluie ou à l’humidité.
1. Lisez ces instructions.
2. Conservez ces instructions.
3. Respectez tous les avertissements.
4. Suivez toutes les instructions.
5. Ne pas utiliser cet appareil près de l’eau.
6. Nettoyer avec un chiffon sec.
7. Ne pas bloquer les ouvertures de ventilation . Installer conformément aux instructions du
fabricant.
8. Ne pas installer près de sources de chaleur telles que des radiateurs , registres de chaleur,
poêles ou autres appareils (incluant les amplificateurs) qui produisent de la chaleur.
9. Ne pas contourner le dispositif de sécurité de la fiche polarisée ou de mise à la terre . Une
fiche polarisée possède deux lames dont une plus large que l’autre . Une fiche de terre
a deux lames et une troisième broche de mise à la terre . La lame large ou la troisième
broche sont fournies pour votre sécurité . Si la fiche fournie ne rentre pas dans votre prise,
consultez un électricien pour le remplacement de la prise obsolète.
10. Protégez le cordon d’alimentation ne soit piétiné ou pincé, en particulier au niveau des
fiches , des prises de courant et le point de sortie de l’appareil.
11. N’utilisez que des fixations / accessoires spécifiés par le fabricant.
12. Utilisez uniquement avec le chariot, le trépied, le support ou la table spécifiépar le
fabricant, ou vendu avec l’appareil. Quand un chariot est utilisé, faites attention en
déplaçant l’ensemble chariot/appareil pour éviter les blessures en cas de renversement.
13. Débranchez cet appareil pendant les orages ou lorsqu’il n’est pas utilisépendant de longues
périodes de time. Refer à un technicien qualifié personnel . Une réparation est nécessaire
lorsque l’appareil a étéendommagé de quelque façon que ce cordon d’ alimentation ou la prise
estendommagé , du liquide a été renversé ou des objets sont tombés dans l’appareil, l’appareil
a été exposé à la pluie ou à l’humidité ,ne fonctionne pas normalement , ou s’il est tombé .
14. Ce produit utilise une classe I ( ou la terre) construction et doit être raccordé à une prise de
courant mise à la terre avec une protection ( ou masse) .
15. NE PAS EXPOSER CET APPAREIL À éclaboussures et s’assurer qu’aucun OBJET REMPLI DE
LIQUIDE , TEL QU’UN VASE , sont placés sur le MATÉRIEL .
16. Pour déconnecter totalement cet appareil du secteur, débranchez la CORDON D’ALIMENTATION
fiche de la prise secteur.
17. LA PRISE PRINCIPALE DU CORDON D’ALIMENTATION doit rester facilement accessible .
18. ATTENTION: POUR RÉDUIRE LE RISQUE DE CHOC ÉLECTRIQUE, NE PAS RETIRER. NO réparable
par l’utilisateur pièces à l’intérieur. CONFIER L’ENTRETIEN DE PERSONNEL QUALIFIÉ .
ATTENTION ! RISQUE DE CHOC ! ÉLECTRIQUE PAS OUVRIR !
CAUTION
Risk of Electrical Shock!
DO NOT OPEN!
!
Le flash de foudre avec le symbole de pointe de flèche, dans une triangle équilaterale, est prévu pour
alerter l’utilisateur à la présence de la tens ion dangereuse non isolée dans la clôture du produit qui
peut être de la grandeur suffisante pour constituer un risque de décharge électrique aux personnes..
Le point d’exclamation dans une triangle équilaterale est prévu pour alerter l’utilisateur à la
présence des instructions importantes de fonctionnement et d’entretien (entretien) dans la
littérature accompagnant l’appareil.
page | 4
INTRODUCTION
Thank you for purchasing Episode® amplifiers. To complete installation, follow these
instructions. Visit our website for design recommendations and speaker calculators.
The ESA-70V2CH 2-channel, 70-volt digital power amplifier series is designed for applications
requiring two channel stereo audio, or two mono zones of audio with different sources or
levels.
IP CONTROL
This amplifier is capable of IP control. The default IP address is 192.168.100.115. The default
username and password is “admin”. For more information on setup using the WebGUI, refer
to the Configuration Utility Manual available on the product support tab.
CONTENTS
1x ESA-70V2CH-150/300/500W Amplifier 4x Removable Feet
1x Detachable 6ft IEC Power Cable 1x Installation Manual
2x Mounting Ears for Amplifier
TOOLS
2.0mm slotted Flathead Screwdriver
Wire Strippers
SPEAKER RECOMMENDATION
The ESA-70V2CH amplifier is only meant to be used with 70V loudspeakers. Use any
combination of speakers as long as the sum of the wattage does not exceed the rated
wattage of the speaker output.
page | 5
© 2019 Episode®
FRONT PANEL
ESA-70V2CH-150W, 300W
PROT -30 -20 -10 CLIP
1
2
ESA-70V2CH-IP-150W
ESA-70V2CH-500W
PROT -30 -20 -10 CLIP
1
2
ESA-70V2CH-IP-500W
A. Power Switch with LED Indicator
Momentary switch for manual control of standby power mode.
BLUE – On.
RED – Standby.
B. Protection LED
Indicates whether a channel is operating correctly or is in protection.
BLUE – Normal.
RED – Protection. (Indicates an issue with installation or setup)
C. Output Level Meter
Level meter flashes green to indicate current output level for each channel. LEDs will
illuminate green accordingly as levels ranging from -30dB to -10dB are played. If a
channel is clipping, the red CLIP LED will illuminate during periods of clipping (turn down
input gain immediately if clipping occurs).
A B C
A B C
page | 6
REAR PANEL
ESA-70V2CH-150W, 300W
ETHERNET
12V TRIGGER
IN
OUT
LOOP
OUT
CH1
CH2
UNBALANCED
INPUTS
BALANCED INPUTS
CH3
CH4
LEVEL
CH1 CH2
SPEAKER OUT
CH1 CH2
+
_
+
R
UTILISER UN FUSIBLE DE RECHANGE
DE MEM E TYP E ET CAL I BR E .
ATTENTION:
FOR CONTINUED PROTECTION AGAINST
RISK OF FIRE, REPLACE ONLY WITH
SAM TY PE F USE A ND RATING.
CAUTION:
E
S
IR RS232
TxRx
In1
In2
DRY
CONTACT
G G
+
_
+
_
G G
_
100/120V~60Hz 3.15A
T3.15A L 250V
220/240V~50Hz 1.6A
T1.6A L 250V
VOLTAGE
SWITCH ON
BOTTOM
ESA-70V2CH-500W
ETHERNET
12V TRIGGER
IN
OUT
LOOP
OUT
CH1
CH2
UNBALANCED
INPUTS
BALANCED INPUTS
CH3 CH4
+
_
+
_
LEVEL
CH1 CH2
SPEAKER OUT
CH1 CH2
+
_ _
+
R
UTILISER UN FUSIB LE DE RECHANGE
D E M E ME T YP E E T C A LI B R E.
ATTENTION:
FOR CONTINUED PROTECTION AGAINST
RISK OF FIRE, R EPLACE O NLY WITH
SAM TYP E F USE AND R ATIN G.
CAUTION:
E
100/120V~60Hz 10A
T10A L 250V
S
IR RS232
TxRx
220/240V~50Hz 5A
T5A L 250V
In1
In2
DRY
CONTACT
G G
G G
VOLTAGE
SWITCH ON
BOTTOM
A. Ethernet Port
RJ45 port for connecting an Ethernet Cat5e/6 cable for IP control of the amplifier.
B. IR
Control the amplifier via IR from your control system. This input accepts a mono connector
– Signal and GND only, no 12V signal supplied.
C. RS-232
To communicate with a control system or PC for serial control of the amplifier.
D. Dry Contact
Use dry contact to toggle amp ON/OFF, or mute/unmute. Setup through web GUI.
E. 12 Volt Trigger IN and OUT
When 4.5-15 Volts DC are applied to 12V IN, amplifier will turn on. When voltage is
dropped, amplifier turns back off. 12V OUT allows other equipment to be controlled from
the same 12V signal.
F. Loop Outputs 1 & 2
Unbalanced mono RCA connections for sending audio to other devices.
G. Unbalanced Inputs 1 &2
Unbalanced mono RCA input connections for connection of sources.
H. Balanced Inputs 3 & 4
Set-screw connections for sources with balanced output.
I. Output Level Adjustment Dials
Digital encoder to adjust output volume levels. Turn clockwise to send volume increase
commands and counter-clockwise to send volume decrease commands.
A E GF
B C D
H I J LK
A E GF
B C D
H I J LK
page | 7
© 2019 Episode®
J. Speaker Output Connections
Set-screw connections for speaker output channels 1 & 2. Accommodates 22-14AWG
wire.
K. IEC Power Cord
Detachable power for amplifier.
L. AC Fuse
Replaceable main power fuse.
BOTTOM PANEL
INPUT
VOLTAGE
5
1
1
115
INPUT
VOLTAGE
INPUT
VOLTAGE
230
230
INPUT
VOLTAGE
Input Voltage Switch
Set the input voltage for 115V or 230VAC operation based on the voltage available.
NOTE: The ESA-70V2CH includes an IEC cable meant for use with a NEMA 5-15 receptacle
supplying 115V AC power. For countries utilizing 230V AC power, the cable can be swapped
to the correct cable for that region. When using the 230V AC input voltage setting, change the
fuse in the amplifier from the included to a fuse rated for 230V AC. See the Specifications on
page14 for the correct fuse type for each model. Using the wrong fuse could result in blown
fuses or damage to the amplifier, which is not covered by the warranty.
Input Voltage
Switch
page | 8
POSITIONING THE AMPLIFIER
Placing the amplifier can have a large impact on performance and longevity. Please take the
following guidelines into consideration.
Shelf Mounting
Be sure that the unit is in a well-ventilated area that provides adequate cooling.
Do not block the cooling vents located on both sides of the unit.
Do not place the unit on carpeting or any similar material.
Do not install the unit near a source of heat, or in an extremely humid or wet location.
If your installation lacks good air flow (such as solid cabinet doors or wall-mounted
racks), it may be necessary to create ventilation to allow outside air into the space.
A minimum of 2 of free space should be allowed above and below the unit for optimum
performance.
EA-AMP-SUB-1D-150
Minimum of 2" of free air
space above
page | 9
© 2019 Episode®
Rack Mounting
Rack mount ears may be removed if not needed.
Bottom feet on the amplifier chassis may be removed if necessary.
NOTE: Do not place the screws back into the chassis. Without the feet, the length of the
screw may touch internal components and affect the performance of the amplifier.
Attach the included rack-mount ears to the front sides of the amplifier chassis.
Securely mount the amplifier into an equipment rack. The amplifier will occupy 1U of
rack space.
Ensure that the unit is in a well-ventilated area that provides adequate cooling.
Free air space is required above the amplifier and below the amplifier. The
recommended distance is 1U to 2U, 1.75" to 3.5" being sure to avoid blocking any vents
on the unit’s chassis
POWER 2
1
PROT -20 -10 CLIP-30
ECA-70AMP-2D-300A
Attach ears using supplied
screws (4 on each side)
Remove Feet
Minimum of 1.75" of free air
space above and below
Minimum of 1.75" of free air
space above and below
Minimum of
2" of depth
behind unit to
accommodate
cables and
connectors
Minimum of 3" free air
space on each side
page | 10
SOURCE CONNECTIONS
Balanced Input
Use the BALANCED INPUT to connect balanced or unbalanced cables to the amplifier.
Unbalanced Connections
Use standard RCA cables to connect sources using the UNBALANCED LINE IN input. Connect
sources through the applicable mono input. Use the LOOP OUT ports to connect more
amplifiers or equipment.
ETHERNET
12V TRIGGER
IN
OUT
LOOP
OUT
CH1
CH2
UNBALANCED
INPUTS
BALANCED INPUTS
S
IR RS232
TxRx
In1
In2
DRY
CONTACT
G G
Using Fixed Output Loop Out
The LOOP OUT connections on the amplifier may be used to send audio signals to other
equipment, or to the other channel of the amplifier. This connection sends audio signals out
from the UNBALANCED INPUT of the channel.
12V TRIGGER
IN
OUT
LOOP
OUT
CH1
CH2
UNBALANCED
INPUTS
BALANCED INPUTS
CH3
CH4
LEVEL
CH1
CH2
SPEAKER OUT
CH1 CH2
+
_
+
S
IR RS232
TxRx
In1
In2
DRY
CONTACT
G G
+
_
+
_
G G
_
12V TRIGGER
IN
OUT
LOOP
OUT
CH1
CH2
UNBALANCED
INPUTS
BALANCED INPUTS
CH3
CH4
LEVEL
CH1
CH2
SPEAKER OUT
CH1 CH2
+
_
+
S
IR RS232
TxRx
In1
In2
DRY
CONTACT
G G
+
_
+
_
G G
_
CH 1 CH 1
Positive(+)
Positive(+)
Negative(-)
Negative(-)
Negative(-) Negative(-)
Positive(+)
Positive(+)
Note jumper between Shield and Negative(-).
Create the adapter shown above if there is
no balanced source and more unbalanced
source connections to the amp are needed.
Shield Shield
Shield Shield
Ch 2 Ch 2
Unbalanced
Loop Out 1&2
Unbalanced
Line IN 1&2
Unbalanced input can be looped out
From Source
Connect Channel 1 Loop OUT to Channel 2 Loop IN for
two channels with one source, or to equipment.
page | 11
© 2019 Episode®
SPEAKER CONNECTIONS
Use 14 or 16 gauge stranded two-conductor speaker wire. Connect the appropriate conductor
to each screw terminal, observing correct polarity.
CONTROL CONNECTIONS
IR
Connect a control system to this input via a mono connector (Signal and GND only, no 12V
signal supplied) to control the amplifier via IR from your control system. See page 6 for IR
port location.
Tip Signal
Sleeve Ground
RS-232
Connect using the correct pin configuration for the control system in use. Configuration for
control system serial ports can vary. Refer to the documentation for the system in use to
ensure proper connection and configuration.
TheESA-70V2CH-IP receives control data on pin 2 (RxD – Data Receive) and transmits control
data on pin 3 (TxD-Data Transmit). See the diagram below for details.
Pin Function
2 RxD (Data Receive)
3 TxD (Data Transmit)
5 Ground/Common
IP
1. Connect a Cat5e/6 network cable from the Ethernet port of the amplifier to a network
with DHCP enabled (DHCP server is usually in the router).
2. Use an IP scanner to detect the IP address assigned to the amplifier.
3. Enter the IP address into a web browser to access the user interface and change
settings.
Default Login Information:
Username: admin
Password: admin
The following settings can be changed in the web GUI:
System Status Power On settings
Input/Output configuration Network IP and Clock settings
Audio Routing configuration Password settings
Sleeve
Tip
5 3 2
DB9 Female Connector
RxD (Data Receiver
TxD (Data Transmit)
GND
page | 12
AMPLIFIER POWER CONTROL
Front Panel Power Button
When the amplifier is powered ON, the power button will illuminate solid blue. When it is in
STAND-BY, the power button will be red.
Resetting the Amplifier
Press and hold the power button for 10 seconds once the receiver is powered on for a “soft”
reset. This will reset login information.
Press and hold for 20 seconds to initiate a factory reset. The front panel lights will flash
indicating the reset is in progress. This will reset all settings including DSP, channel levels
and input names.
12 Volt Trigger
The ESA-70V2CH-IP line of amplifiers are equipped with 12V DC trigger inputs and outputs
for trigger control and daisy chain control of more than one amplifier.
To utilize the 12V DC trigger function, attach a mono mini cable between the 12V trigger
output of the controlling device and the 12V DC TRIGGER IN port of the amplifier. Connect
other devices to the OUT port on the amplifier using a mono-mini cable.
12V TRIGGER
IN
OUT
Cable 3.5mm Mono-mini
Tip 4.5-15V DC (constant during use)
Sleeve Ground/Common
12V TRIGGER
IN
OUT
LOOP
OUT
IR RS232
TxRx
In1
In2
DRY
CONTACT
12V TRIGGER
IN
OUT
LOOP
OUT
IR RS232
TxRx
In1
In2
DRY
CONTACT
Audio Sense
If Audio Sense is enabled via setup through the web GUI, the amplifier will turn on when an audio
signal is detected. The unit will enter standby mode if no signal is detected after 15 minutes. See
the Configuration Utility for details on how to set up Audio Sense.
Sleeve
Tip
From Source
To Other Devices
page | 13
© 2019 Episode®
APPLICATION DIAGRAM
See the examples of applications below. These diagrams illustrate typical uses of the
ESA-70V2CH amplifier.
Single Source with Stereo Output
Left
(CH 1)
Right
(Ch 2)
ETHERNET
12V TRIGGER
IN
OUT
LOOP
OUT
CH1
CH2
UNBALANCED
INPUTS
BALANCED INPUTS
CH3
CH4
LEVEL
CH1 CH2
SPEAKER OUT
CH1 CH2
+
_ _
+
R
UTILISER UN FUSIBLE DE RECHANGE
DE M EM E T YP E ET C A LI B R E.
ATTENTION:
FOR CONTINUED PROTECTION AGAINST
RISK OF FIRE, REPLACE ONLY WITH
SAM TYP E FU SE AND RATI NG.
CAUTION:
E
100/120V~60Hz 3.15A
T3.15A L 250V
220/240V~50Hz 1.6A
T1.6A L 250V
S
IR RS232
TxRx
In1
In2
DRY
CONTACT
G G
+
_
+
_
G G
Two Sources with Two Mono Output Zones
Zone 2
(CH 2)
Zone 1
(Ch 1)
ETHERNET
12V TRIGGER
IN
OUT
LOOP
OUT
CH1
CH2
UNBALANCED
INPUTS
BALANCED INPUTS
CH3
CH4
LEVEL
CH1 CH2
SPEAKER OUT
CH1 CH2
+
_ _
+
R
UTILISER UN FUSIBLE DE RECHANGE
DE M EM E T YP E ET C A LI B R E.
ATTENTION:
FOR CONTINUED PROTECTION AGAINST
RISK OF FIRE, REPLACE ONLY WITH
SAM TYP E FU SE AND RATI NG.
CAUTION:
E
100/120V~60Hz 3.15A
T3.15A L 250V
220/240V~50Hz 1.6A
T1.6A L 250V
S
IR RS232
TxRx
In1
In2
DRY
CONTACT
G G
+
_
+
_
G G
ESA-70V2CH-150W, 300W
Source 2
(Unbalanced Input)
From Automation
System
12V Trigger Output
Source 1
(Unbalanced RCA)
LOOP OUT option
for use with
additional amps.
LOOP OUT option
for use with
additional amps.
NOTE:
Source 2
Balanced
Audio
cannot be
looped out
ESA-70V2CH-500W
Left to CH 1
Right to CH 2
CH 1 Loopout
page | 14
Volume Calibration
To calibrate source input gain and inline volume control level:
1. Connect all speaker and audio source wiring. Connect power to the amplifier.
2. (If applicable) Set all volume controls to their maximum volume setting.
3. Set each output level adjustment knob to 50% and set the input level for unused
channels to minimum.
4. Power on the amplifier and the source to be used. Play audio typical of what will be
played in the area. Set the source volume level to half. If the audio becomes distorted,
turn the volume down until audio is clear.
5. Set the level adjustment for the area to a level where the volume is slightly above
normal listening level. If the audio becomes distorted, experiment with changes to the
source volume and the LEVEL adjustment knob until audio is clear.
6. Log in to the WebGUI and go to Configuration > Input/Output to fine tune the Gain
settings for each port.
Note: The default IP address for the amplifier is 192.168.100.115. The default username
and password is “admin”. For more information on setup using the WebGUI, refer to the
Configuration Utility Manual available on the product support tab.
Calibration Setup Tips
Poor Calibration may cause the following issues. Use the tips below to identify and correct
these problems:
Distorted Audio at Normal Volume
If the LEVEL adjustment for a zone is set too high to compensate for low source volume,
distortion can occur in the form of background noise or poor audio quality. This will be heard as
a steady hissing or humming behind music, clipping of signal, or distortion of highs and lows.
To eliminate this issue, re-adjust the volume levels by starting at baseline settings and
re-adjusting the final volume so that a maximum comfortable volume level can be reached
with no distortion while using the source volume or inline control.
Inline Volume “Thump” or Play Source Audio in the Walls
If inline volume thumps or resonate in the walls, the amplifier and source volume levels are set
too high. Inline volume controls should be calibrated so that they are one or two adjustment
levels away from their maximum setting when audio is at the normal listening level. This will
leave one to three settings above normal level for use if a little extra volume is needed.
OvrC®
Adding the ESA-70V2CH-IP to an OvrC Account
Step 1. Connect the IP Device to the Internet
The amplifier must be powered on and connected to a LAN with Internet access to activate
an OvrC connection.
Refer to the manual for installation instructions. Once the device has been activated, it can be
added to the account, even if the device is not online when added.
Step 2. Log Into OvrC
Create a new account at www.OvrC.com, or log into an existing account.
Step 3. Add the Device
Select “Add a Device” and enter the device’s MAC address and serial number (this information
can be found next to the service tag on the product). If OvrC locates the device, directions to
continue setup will be displayed. If OvrC does not locate the device, confirm, then re-enter the
page | 15
© 2019 Episode®
MAC address and serial number.
Once setup is complete, all OvrC features can now be accessed via a smartphone or tablet
application, or via the Internet at www.OvrC.com
SPECIFICATIONS
ESA-70V2CH-150W ESA-70V2CH-300W ESA-70V2CH-500W
Continuous Power
Output (All Channels)
150w per channel
@ 70V
300w per channel
@ 70V
500w per channel
@ 70V
Inputs per Channel 1 unbalanced (RCA) and 1 balanced (set-screw)
Input Sensitivity 775mV
Input Impedance 10KΩ (unbalanced); 20KΩ ( balanced)
AUTO ON Sensitivity 2.5mV
12 Volt Trigger Input 4.5-12V DC; 10K Ω
12 Volt Trigger Output 12V DC; 10mA
S/N ratio 95db A-weighted
Frequency Response 50 Hz to 20KHz
Distortion 0.1% THD 20 Hz-20 kHz
Input Voltage 115V AC/230V AC
Fuse 115V AC T3.15AL 250V T6.3AL 250V T10AL 250V
230V AC T1.6AL 250V T3.15AL 250V T5AL 250V
Power Consumption 400 watts 800 watts 1200 watts
Dimensions (Inches) 17"W x 1.73"H x 14"D 17"W x 3.49"H x
15”D
Weight 11.9 lbs 12.9 lbs 17.4 lbs
Certification Meets FCC Part 15, UL EN60065
DIMENSIONS
19.00in.
17.00in.
1.73in.
2.10in.
19.00in.
17.00in.
3.49in
3.86in
14.00in.
15.00in.
PROT -30 -20 -10 CLIP
1
2
ECA-70IPAMP-2D-150
PROT -30 -20 -10 CLIP
1
2
ESA-70V2CH-500W
© 2019 Episode®
Rev: 190219-1530
TROUBLESHOOTING
Amplifier will not turn on. 1. Power cable to the amplifier is incorrectly connected
or plugged into an outlet that does not have power.
Check connections and verify power on the outlet.
2. Main Power Fuse is blown. Replace fuse and ensure
the AC voltage switch is set correctly on the bottom of
the amplifier.
POWER LED is red. 1. Amplifier is in Protection mode. Too much current
being drawn on speaker output. Verify all wiring and
connections.
2. Calculate load attached to amp and configure so that
wattage output is within specification.
3. Amplifier is overheating. Unplug amp and let cool.
Install per instructions in manual, “Positioning the
Amplifier”.
Hum or buzzing sound is
heard.
Check RCA input cables by removing them one at time
and checking to see if a connection or cable is to blame.
No audio from speakers. 1. Verify speakers and wiring connections. Log in to
the WebGUI and go to Configuration > Input/Output
and use the OUTPUT test tone function to test if each
output can produce sound.
2. Verify correct source operation and input wiring. Turn
volume in source up to an audible level.
3. Is Power LED red? If so, see section above, “POWER
LED is RED”.
No sound from microphone
input.
Set the phantom power switch to the correct mode
for microphone, and verify the correct mode with
microphone manufacturer.
CLIP LED illuminates some
or all of the time.
Turn down the input gain. The amplifier is trying to push
too much power to the speakers.
WARRANTY
2-Year Limited Warranty
Episode® Amplifiers have a 2-Year Limited Warranty. This warranty includes parts and
labor repairs on all components found to be defective in material or workmanship under
normal conditions of use. This warranty shall not apply to products that have been
abused, modified or disassembled. Products to be repaired under this warranty must
be returned to a designated service center with an assigned return authorization (RA)
number. Contact technical support at [email protected] for an RA number.
CONTACTING TECHNICAL SUPPORT
866.838.5052
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Episode ESA-70V2CH-500W Guide d'installation

Catégorie
Matériel musical
Taper
Guide d'installation
Ce manuel convient également à

dans d''autres langues