DL2202
Smart Desk Lamp
Touch Button
DL2202 Smart Desk Lamp Status
Status DL2202
Turning on the first time Searching Wi-Fi White light at 5% brightness
Pairing White light at 5% brightness
Device added successfully White light at 50% brightness
Identifying the Smart Desk Lamp White light at 5% brightness blinks quickly 3 times
Firmware update completed Blinks twice
Factory Reset 5% brightness blinks quickly 5 times.
DL2202 Smart Desk Lamp
AC/DC Adapter
User Manual
What‘s lncluded
Specifications
Input: 12V,2A
Power: 24W Max
Wireless charging power: 10W
Brightness:600Lm
Average beam angle: 100°
Expected LED life: 25000H
Working temperature: 0~40
Color temperature:
2700K – 6500K (including 2700K,
3600K,4600K, 5500K, 6500K)
Wi-Fi 2.4GHz b/g/n IEEE802.11
Operation frequency band(s):
2412~2462MHz
VOCOlinc APP
20220610
Product Overview:
System Requirements
Handsfree voice control and with cool to warm whites, the DL2202 Smart
Desk Lamp is here to make your home truly yours.Utilizing the latest in
Wi-Fi technology, DL2202 Smart Desk Lamp enables you to set the color
temperature and intensity of any area via VOCOlinc app. With countless
uses and applications, an all-new world awaits you with the VOCOlinc
DL2202.
You can customize your personal lighting from anywhere with an active
internet connection.
Note:
* After Factory Reset , All connection data will be cleared . The Smart Desk
Lamp must be removed from the app and then add it back again.
* If you set the brightness to 0% before turning off the light switch, the smart
Desk Lamp will resume to 100% brightness as soon as you turn on the light
switch again to indicate that it is in good shape.
Mobile device running the latest version of iOS and Android 4.3 or above
Existing Wi-Fi network (2.4GHz)
Stable Internet with good signal strength
WARNING: RISK OF ELECTRIC SHOCK OR BURNS. DO NOT install this
product with wet hands or standing on wet or damp surfaces
Not suitable for use with standard in-wall dimmers. Dimmable via the app
or Touch bar.
Place on flat or secure surface.
Only use the supplied AC Power Adapter
Keep the Lamp dry and clean
NOT FOR EMERGENCY LIGHTING
DO NOT disassemble
DO NOT clean with liquid
Avoid any extreme heat sources or direct sunlight.
Suitable for use in operating environment between 0°C and 40°C
(32°F and 104°F)
Safety Warnings
1 Power Button Short tap to turn on/off
Hold for 10s to reset
2 Brightness min Slide the Touch Bar to adjust the light
brightness you prefer(5 Levels).
From left to right, Brighten the light
From right to left, Dim the light
3 Brightness max
4 Mode Button Tap to change color temperature
5 Wireless Charge Area for Wireless charging
6 Status LED Smart Desk Lamp Status
FCC Declaration
Caution:
EU declaration of conformity
Hereby, Felion Technologies Company Limited declares that the radio
equipment Smart Desk Lamp is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following
internet address: www.vocolinc.com
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
undesired operation. Any Changes or modifications not expressly approved
by the party responsible
operate the equipment.
The antenna(s) used for this transmitter must be installed to provide a
separation distance of at least 20 cm from all persons and must not be
co-located or operating in conjunction with any other antenna or transmitter.
Any Changes or modifications not expressly approved
for compliance could void the user's authority to
ISED Statement
The digital apparatus complies with Canadian CAN ICES 3 (B)/NMB 3(B).
French: L’émetteur/récepteurexempt de licence contenu dans le présent appareil est
conforme aux CNR d’Innovation, Sciences et DéveloppementéconomiqueCanada
applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux
deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage
est susceptible d'en compromettre le fonctionnement.
l'appareil numérique du ciem conforme canadien peut 3 (b) / nmb 3 (b).
This device meets the exemption from the routine evaluation limits in section 2.5 of
RSS 102 and compliance with RSS 102 RF exposure, users can obtain Canadian
information on RF exposure and compliance.
cet appareil est conforme à l'exemption des limites d'évaluation courante dans la
section 2.5 du cnr - 102 et conformité avec rss 102 de l'exposition aux rf, les
utilisateurs peuvent obtenir des données canadiennes sur l'exposition aux champs rf
et la conformité.
This equipment complies with Canada radiation exposure limits set forth for an
uncontrolled environment.
This equipment should be installed and operated with minimum distance 20cm
between the radiator & your body.
Cet équipement est conforme Canada limites d'exposition aux radiations dans un
environnement non contrôlé.
Cet équipement doit être installé et utilisé à une distance minimale de 20 cm entre le
radiateur et votre corps.