Automationdirect.com Productivity 3000 P3-08AD Guide de démarrage rapide

Taper
Guide de démarrage rapide
Sales 800-633-0405 www.automationdirect.com/P3000Tech Support 770-844-4200
1
To minimize the risk of potential safety problems, you should follow
all applicable local and national codes that regulate the installation
and operation of your equipment. These codes vary from area to
area and it is your responsibility to determine which codes should
be followed, and to verify that the equipment, installation, and oper-
ation are in compliance with the latest revision of these codes.
Equipment damage or serious injury to personnel can result
from the failure to follow all applicable codes and standards. We
do not guarantee the products described in this publication are
suitable for your particular application, nor do we assume any
responsibility for your product design, installation, or operation.
If you have any questions concerning the installation or opera-
tion of this equipment, or if you need additional information, please
call Technical Support at 770-844-4200.
This publication is based on information that was available at
the time it was printed. At AutomationDirect.com® we constantly
strive to improve our products and services, so we reserve the right
to make changes to the products and/or publications at any time
without notice and without any obligation. This publication may also
discuss features that may not be available in certain revisions of
the product.
P3-08AD Analog Input
The P3-08AD Voltage/Current Analog Input
Module provides 8 channels for receiving ± 10
VDC, ± 5 VDC, 0 to 5 VDC, 0 to 10 VDC, and 0 to
20mA signals for use with the Productivity3000
Programmable Automation Controller.
Safety Information .............1
Removable Terminal Block
Specifications ..............1
General Specifications .........2
Input Specifications ............2
Schematic and Wiring Diagram ...3
Module Installation Procedure .... 4
Terminal Block Removal ........4
Hot Swap Information ..........4
Wiring Options ................ 5
Module Configuration ..........5
Linear Scaling ................6
Non-Linear Scaling ............6
LCD Panel Display Menus ......7
Warranty: Thirty-day money-back guarantee. Two-year limited replacement.
(See www.automationdirect.com/P3000 for details).
Terminal Block sold separately, Terminal Block Cover included
(see wiring options on page 5).
Removable Terminal Block Specifications
Number of Positions 20 screw terminals
Wire Range 22-14 AWG (0.324 to 2.08 sq. mm)
solid / stranded conductor
3/64 in. (1.2 mm) insulation maximum
“USE COPPER CONDUCTORS, 60°C” or equivalent.
Screw Driver Width 1/4 inch (6.5 mm) maximum
Screw Size M3 size
Screw Torque Field terminals – 7 - 9 in./lb (.0.882 - 1.02 Nm)
Self-jacking screws – 2.7 - 3.6 in./lb (0.3 - 0.4 Nm).
Do not overtighten screws when installing terminal block.
Tech Support 770-844-4200www.automationdirect.com/P3000
2
Input Specifications
Input Channels 8
Module Signal Input
Ranges
±10VDC, ±5VDC, 0 - 5VDC, 0 - 10VDC,
0 - 20mA
Signal Resolution 16-bit
Resolution Value of LSB
(least significant bit)
1 LSB = 1 count
±10V = 305µV
±5V = 152µV
0 - 5V = 76µV
0 - 10V = 152µV
0 - 20mA = 0.305µA
Data Range 0 to 65535 counts unipolar
-32768 to +32767 counts bipolar
Maximum Continuous
Overload
±31mA, current input
±100V, voltage input
Input Impedance
1MV ±10% voltage input
250V ±0.1%
1/4
W. current input
Hardware Filter
Characteristics
Low pass 1st order, -3dB@48Hz
Sample Duration Time 455µs per channel
(does not include ladder scan time)
All Channel Update Rate 4ms
Open Circuit Detection
Time
Zero reading within 1s (current input only)
Conversion Method Successive Approximation
Accuracy vs. Temperature ±10PPM / °C Maximum
Maximum Inaccuracy 0.1% of range voltage, 0.2% of range current (including
temperature drift)
Linearity Error (end to
end)
±0.01% of range max., ±10V & ±5V
±0.015% of range max., 0-10V, 0-5V & 0-20mA
Monotonic with no missing codes
Input Stability and
Repeatability
±0.035% of range (after 10 min. warmup)
Full Scale Calibration
Error
±0.2% of range maximum
Offset Calibration Error ± .065% of range maximum
Max Crosstalk -96dB
Recommended Fuse
(external)
Edison S500-32-R
, .032A fuse
on current inputs only
External DC Power
Required
24VDC (-20% / + 25%) 33mA
General Specifications
Operating Temperature 0° to 60°C (32° to 140°F),
Storage Temperature -20° to 70°C (-4° to 158°F)
Humidity 5 to 95% (non-condensing)
Environmental Air No corrosive gases permitted
Vibration IEC60068-2-6 (Test Fc)
Shock IEC60068-2-27 (Test Ea)
Field to Logic Side Isolation 1800 VAC applied for 1 second
Insulation Resistance
>10MV @ 500 VDC
Heat Dissipation 1.1 W
Enclosure Type Open Equipment
Agency Approvals UL508 file E157382, Canada & USA
UL1604 file E200031, Canada & USA
CE (EN61131-2*)
This equipment is suitable for use in Class 1,
Division 2, Groups A, B, C and D or non-hazardous
locations only.
Module Keying to Backplane Electronic
Module Location Any I/O slot in any local, expansion, or remote
base in a Productivity3000 System.
Field Wiring Removable terminal block (not included). Use
ZIPLink Wiring System or optional terminal block.
See “Wiring Options” on page 5.
EU Directive See the “EU Directive” topic in the
Productivity3000 Help File. Information can also be
obtained at: www.automationdirect.com/P3000
Terminal Type (not included) 20-position removable terminal block
Weight 105g (3.73 oz)
*Meets EMC and Safety requirements. See the D.O.C. for details.
WARNING: Explosion hazard – Substitution of components may impair suitability
for Class I, Division 2.
AVERTISSEMENT: Risque d’explosion : la substitution de composants peut com-
promettre la convenance pour la Classe I, Zone 2 ou pour la Classe I, Division 2.
Sales 800-633-0405 www.automationdirect.com/P3000Tech Support 770-844-4200
3
Schematic
L INTERNA MODUL E
CIRCUIT R Y
ISOL A TE D
ANALOG
CIRCUIT
POWER
ISOLA TED ANALOG
CIRCUIT COMMON
V1+
V2+
I1+
I2+
V3+
V4+
I3+
I4+
COM
COM
V5+
V6+
I5+
I6+
V7+
V8+
I7+
I8+
24VDC-
24VDC+
V1+
V2+
I1+
I2+
V3+
V4+
I3+
I4+
COM
COM
V5+
V6+
I5+
I6+
V7+
V8+
I7+
I8+
24VDC-
24VDC+
CH1 ADC
CH2 ADC
CH3 ADC
CH6 ADC
CH5 ADC
CH7 ADC
CH8 ADC
CH4 ADC
- +
24 VDC User
Supplied Power
Wiring Diagram
Voltage Input Circuits
Current Sinking Input Circuits
An Edison S500-32-R 0.032A fast-acting
fuse is recommended for all current loops.
COM
V+
4-Wire Voltage
Transmitter
4-Wire Transmitter
Optional Transmitter
Power Supply
AC or DC
- +
24 VDC User
Supplied Power
+
3-Wire Voltage
Transmitter
V+
COM
3-Wire Transmitter
.032A
2-Wire 4-20 mA
Transmitter
fuse
fuse
.032A
fuse
+
.032A
- +
- +
V+
I+
COM
V+
I+
3-Wire Current
Transmitter
4-Wire 4-20 mA
Transmitter
2-Wire Transmitter
3-Wire Transmitter
4-Wire Transmitter
Power
Supply
24VDC User
Supplied Power
+
+
+
User Supplied
Transmitter Power
AC or DC
V+
I+
COM
COM
Tech Support 770-844-4200www.automationdirect.com/P3000
44
Terminal Block Removal
1. Pull hinged
door open
here.
NOTE: Do not grip
door in middle.
IMPORTANT
Torque = 2.7-3.6 in./lb (0.3 -0.4 Nm).
Do not overtighten screws when
installing terminal block.
2. Loosen self-
jacking screws
to disengage
terminal block.
3. Grip opened door along
edge to avoid flexing door
and pull terminal block
from module.
Important Hot-Swap Information
The Productivity3000 PAC supports hot-swap!
Individual modules, expansion bases, and entire
remote base groups can be taken offline, removed, and
replaced while the rest of the PAC system continues
controlling your process. Before attempting to use the
hot-swap feature, be sure to read the hot-swap topic in
the programming software’s help file or our online docu-
mentation at AutomationDirect.com for details on how to
plan your installation for use of this powerful feature.
Module Installation Procedure
WARNING: Do not apply field power until the following
steps are completed. See hot-swapping procedure for
exceptions.
Align
here
Align
here
Step One: Align circuit card with slot and
press firmly to seat module into connector.
To install or remove terminal
block cover, press middle to flex
cover.
AVERTISSEMENT: Ne pas appliquer la puissance de
champ avant l’exécution des étapes qui suivent. Consultez la
procédure de remplacement à chaud pour les exceptions.
AVERTISSEMENT: Risque d’explosion : ne pas connecter ou déconnecter les connec-
teurs ni actionner les commutateurs alors que le circuit est sous tension, à moins que la
zone ne soit reconnue non dangereuse. Ne pas remplacer à chaud les modules à moins
que la zone ne soit reconnue non dangereuse.
Step Two: Pull top and bottom locking
tabs toward module face. Click indicates lock
is engaged.
Step Three: Attach field wiring using
optional terminal block or ZIPLink wiring
system and install cover.
WARNING: Explosion hazard – Do not connect or disconnect connectors or
operate switches while circuit is live unless the area is known to be non-hazardous.
Do not hot-swap modules unless the area is known to be non-hazardous.
Sales 800-633-0405 www.automationdirect.com/P3000Tech Support 770-844-4200
5
Using the Hardware Configuration tool in the
Productivity Suite programming software, drag
and drop the P3-08AD module into the base
configuration.
Select Automatic Module Verification or No
Verification and Enable Hot Swap. Select Range
type for each input. If desired, assign a User
Tagname to each input point (channel) selected
and to each Status Bit Item.
Module Configuration
Wiring Options
ZIPLink Connection System
Cable + ZIPLink Module = Complete System
ZIPLink pre-wired
terminal block cables
0.5m (1.6FT) cable
1.0m (3.3FT) cable
2.0m (6.6FT) cable
ZIPLink Modules
Feed through
ZL-P3-CBL20-L
ZL-P3-CBL20-1L
ZL-P3-CBL20-2L
ZL-RTB20
Terminal Block with pigtail cable
0.5m (1.6FT) cable
1.0m (3.3FT) cable
2.0m (6.6FT) cable
ZL-P3-CBL20-P
ZL-P3-CBL20-1P
ZL-P3-CBL20-2P
Terminal Block only
P3-RTB
(Quantity 1)
2
3
1
Tech Support 770-844-4200www.automationdirect.com/P3000
6
Linear Scaling
0
.5
1
1.55
2.25
3
4.55
6.75
7
0
0
0
0
0
0
0
0
1
2
3
4
5
6
6.5
7
0
0
0
0
0
0
0
Level Transmitte
rT
ank Level
7
0
0
0
0
0
0
0
Select the minimum and maximum
values of the raw input signal. These
values will relate to the minimum
and maximum scaled values.
7
6
5
4
3
2
1
0
1 2 3 4 5 6 7
Non-Linear Scaling
The Scale (Linear) function can be used to:
• Convert analog field input signals from the range which is native to the
analog input module to an application specific range.
• Make other linear conversions in ranges appropriate to the application.
65535
220
12500
Tank Level
0
Control Valve
Select the Input and Output tags appropriate
for the application. Convert raw input signals
to engineering units for use in the program, or
convert engineering units to output signals for
control purposes
max
min
min max
The Scale (Non-Linear) function can be used for Non-Linear
applications.
Sales 800-633-0405 www.automationdirect.com/P3000Tech Support 770-844-4200
7
LCD Panel Display
Momentarily Press
SEL button to
toggle through
secondary displays














Hold SEL button down to cycle through primary screens. Release button to select screen.
Power On



Appears
initially
These screens will
then auto cycle





















 















Fault Messages –
Appear in
place of data during a fault
condition.










Error Messages:
An existing error will
be inserted into the
cycling Status Info
screen.
This screen will
auto cycle with
status information
Input signal is OVER the maximum detectable by the module.
Input signal < range minimum. (Voltage only)
Input signal < 2mA. (Current only)





Note: SPARE
denotes deselected
channel
Tech Support 770-844-4200www.automationdirect.com/P3000
8
Document Name Edition/Revision Date
P3-08AD-M 1st Ed. Rev. B 12/06/2017
Copyright 2017, AutomationDirect.com Incorporated/All Rights Reserved Worldwide
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Automationdirect.com Productivity 3000 P3-08AD Guide de démarrage rapide

Taper
Guide de démarrage rapide