Homelite Portable Generator UT903611 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur

Ce manuel convient également à

OFF
ON
SAVE THIS MANUAL FOR FUTURE REFERENCE
Your generator has been engineered and manufactured to our high standard for dependability, ease of operation, and op-
erator safety. When properly cared for, it will give you years of rugged, trouble-free performance.
DANGER: You WILL be KILLED or SERIOUSLY HURT if you do not follow the instructions in this operator’s
manual.
Thank you for your purchase.
Ce générateur a été conçu et fabriqué conformément à nos
strictes normes de fiabilité, de simplicité d’emploi et de sécurité
d’utilisation. Correctement entretenu, il vous donnera des années
de fonctionnement robuste et sans problème.
DANGER : Le non-respect des instructions fournies
dans ce manuel d’utilisation entraînera des BLESSURES
GRAVES, voire MORTELLES.
Merci de votre achat.
Su generador ha sido diseñado y fabricado de conformidad con
estrictas normas para brindar fiabilidad, facilidad de uso y seguridad
para el operador. Con el debido cuidado, le brindará muchos años
de sólido y eficiente funcionamiento.
PELIGRO: El incumplimiento de las instrucciones en
este manual del operador puede CAUSARLE LA MUERTE O
LESIONARLE GRAVEMENTE.
Le agradecemos su compra.
CONSERVER CE MANUEL POUR
FUTURE RÉFÉRENCE
GUARDE ESTE MANUAL PARA
FUTURAS CONSULTAS
OPERATOR’S MANUAL
Manuel d’utilisation
Manual del operador
3650 WATT GENERATOR
Générateur de 3650 watts
Generador 3650 watts
UT903611 Series
Série UT903611
Serie UT903611
NEUTRAL BONDED TO FRAME
CONNECTEUR NEUTRE RELIÉ AU CADRE / PUNTO NEUTRO CONECTADO AL MARCO
To register your Homelite
product, please visit:
http://register.homelite.com/
Pour enregistrer votre produit de
Homelite, s’il vous plaît la visite:
http://register.homelite.com/
Para registrar su producto de
Homelite, por favor visita:
http://register.homelite.com/
ii
OFF
ON
N
G
E
I
J
K
L
M
See this fold-out section for all
of the figures referenced in the
operator’s manual.
Consulter l’encart à volets afin
d’examiner toutes les figures
mentionnées dans le manuel
d’utilisation.
Consulte esta sección desplegable
para ver todas las figuras
a las que se hace referencia en el
manual del operador.
Fig. 2
F - 240 volt AC, 20 amps receptacle (prise de 240
V c.a. 20 A, 240 V de CA 20 A receptáculo)
G - Cord retainers (retenues de cordon, retén
para el cordón)
H - Engine switch (commutateur du moteur,
interruptor del motor)
I - Oil cap/dipstick (tapa debouchon/jauge
d’huile, relleno de aceite/varilla medidora de
aceite)
J - Oil drainage bolt (vis de vidange d’huile,
perno de drenaje de aceite)
K
- Recoil starter grip (poignée du démarreur à
rappel, mango del arrancador retráctil)
L - Air filter (filtre à air, filtro de aire)
M- Choke lever (levier d’étrangleur, palanca del
anegador)
N - Ground terminal (borne de terre, terminal de
conexión a tierra)
O - Muffler (silencieux, silenciador)
A - Handle lock pin (goupille de blocage de la
poignée, pasador de seguro del mango)
B - Fuel cap (bouchon de carburant, tapa del
tanque)
C - Fuel tank (réservoir de carburant, tanque de
combustible)
D - 120 volt AC 20 amp receptacles (prise de 120
V c.a., 20 A, 120 V de CA 20 A receptáculos)
E - Circuit breaker (disjoncteur de circuit,
disyuntor de circuito)
C
D
D
F
F
B
H
A
A
B
Fig. 1
A - Reset button (bouton de réarmement, botón
de reajuste)
B - Test button (essayer le bouton, botón de
prueba)
O
iii
Fig. 3
3
4
1
5
2
7
14
12
15
11
8
6
10
9
13
16
Fig. 4
B
A - Socket wrench (clé à douille, llave de
casquillo)
B - Combination wrench (clé mixte, llave de
combinación)
A
Fig. 5
A - Bolt (boulon, perno)
B - Frame (cadre, armazón)
C - Washer (rondelle, arandela)
D - Frame support with foot (support de cadre
avec pied, apoyo de bastidor con pie)
E - Flange nut (écrou à embase, tuerca de brida)
F - Lock nut (écrou de blocage, tuerca de
bloqueo)
G - Rubber foot (pied en caoutchouc, pie de
goma)
A
B
C
D
E
F
G
A
C
OFF
ON
The Toughest Name In Tools
E
A
D
F
B
C
A - Lock nut (écrou de blocage, tuerca de
bloqueo)
B - Washer (rondelle, arandela)
C - U-bracket (support en U, soporte en “U”)
D - Wheel (roue, rueda)
E - Wheel spacer (pièce d’écartement de la roue,
espaciador de rueda)
F - Bolt (boulon, perno)
Fig. 6
A
B
C
A - Lanyard (bracelet, correa)
B - Handle lock pin (goupille de blocage de la
poignée, pasador de seguro del mango)
C - Frame (cadre, armazón)
Fig. 7
C
B
D
A
Fig. 8
A - Frame (cadre, armazón)
B - Handle (poignée, mango)
C - Hole (trou, agujero)
D - Handle lock pin (goupille de blocage de la
poignée, pasador de seguro del mango)
iv
A
B
A - Move choke lever left to run (pousser gauche
le levier d’étranglement pour la marche,
desplace izquierda la palanca del anegador
para poner en marcha)
B - Move choke lever right to start (tirer droite
le levier d’étranglement pour démarrer,
desplace derecha de la palanca del anegador
para arrancar)
OFF
OFF
A
B
B
A
(C)
(B)
A
B
C
A
B
Fig. 9
Fig. 10
A - Oil cap/dipstick (bouchon du réservoir d’huile/
jauge d’huile, tapa de relleno de aceite/varilla
medidora de aceite)
B - Oil fill hole (orifice de remplissage d’huile,
agujero de llenado de aceite)
A - Fuel cap (bouchon de carburant, tapa del
tanque de combustible)
B - Fuel tank (réservoir de carburant, tanque de
combustible)
Fig. 11
A - Fuel valve (robinet de carburant, interruptor
del motor)
B - Recoil starter grip (manchon en lanceur à
rappel, mango del arrancador retráctil)
C - Engine switch (commutateur du moteur,
válvula de combustible)
Fig. 12
Fig. 13
Fig. 14
A - Air filter cover (couvercle du filtre à air, tapa
del filtro de aire)
B - Latch (loquet, pestillo)
C - Filter element (élément du filtre, elemento de
filtro)
D - Air filter unit (unité de filtre à air, unidad del
filtro de aire)
Fig. 15
A - Oil drainage bolt (vis de vidange d’huile,
perno de drenaje de aceite)
B - Oil cap/dipstick (bouchon du réservoir d’huile/
jauge d’huile, tapa de relleno de aceite/varilla
medidora de aceite)
A
OFF
ON
OFF
ON
OFF
A
C
D
B
ON
OFF
A - Fuel valve (robinet de carburant, válvula de
combustible)
B - Off (arret, apagado)
C - On (marche, encendido)
v
OFF
A - Spark plug (bougie, bujía)
B - Spark plug cap (capuchon de bougie, tapa de
la bujía)
A
B
Fig. 17
Fig. 16
A - Fuel line (conduites de carburant, conducto
de combustible)
B - Fuel valve (robinet de carburant, interruptor
del motor)
C - Petcock (petit robinet, llave de purga)
D - Off (arret, apagado)
E - On (marche, encendido)
C
A
A
B
A - Carburetor drain screw (vis de vidange
du carburateur, tornillo de drenaje del
carburador)
(E)
ON
(D)
OFF
Fig. 18
OFF
B
A
A - Fuel line (conduites de carburant, conducto
de combustible)
B - Fuel filter (filtre à carburant, filtro de
combustible)
Fig. 20
Fig. 19
Page 2 — English
DANGER:
GROUNDING THE GENERATOR
To reduce the risk of shock or electrocution, generator must be properly grounded.
The nut and ground terminal on the frame must always be used to connect the
generator to a suitable ground source. The ground path should be made with #8
size wire. Connect the terminal of the ground wire between the lock washer and
the nut, and tighten the nut fully. Connect the other end of the wire securely to a
suitable ground source.
The National Electric Code contains several practical ways in which to establish
a good ground source. If a steel or iron rod is used, it should be at least 5/8 in.
diameter, and if a nonferrous rod is used, it should be at least 1/2 in. diameter and
be listed as material for grounding. Drive the rod or pipe to a depth of 8 ft. If a rock
bottom is encountered less than 4 ft. down, bury the rod or pipe in a trench.
All electrical tools and appliances operated from this generator must be properly grounded by use of a
third wire or be “Double Insulated.”
It is recommended to:
1. Use electrical devices with 3-prong grounded plugs.
2. Use an extension cord with a 3-pole receptacle and a 3-prong plug at opposite ends to ensure continuity of the ground pro-
tection from the generator to the appliance.
Check and adhere to all applicable federal, state, and local regulations relating to grounding specifications. Consult a qualified
electrician or service personnel if the grounding instructions are not completely understood or if in doubt as to whether the genera-
tor is properly grounded.
NOTE: Your generator model may not look exactly the same as the model shown. Regardless of whether the generator head is
square or round, the grounding plug location is the same. If you have any questions about the location of the grounding plug on
your generator, please call us at 1-800-242-4672.
This product has many features for making its use more pleasant and enjoyable. Safety, performance, and dependability
have been given top priority in the design of this product, making it easy to maintain and operate.
Introduction .................................................................................................................................................................... 2
Important Safety Instructions .....................................................................................................................................3-4
Specific Safety Rules ..................................................................................................................................................... 4
Symbols ......................................................................................................................................................................5-7
Electrical .....................................................................................................................................................................8-9
Features ...................................................................................................................................................................... 10
Loose Parts List ........................................................................................................................................................... 11
Assembly ................................................................................................................................................................11-12
Operation ................................................................................................................................................................12-14
Maintenance ...........................................................................................................................................................14-16
Troubleshooting ........................................................................................................................................................... 17
Warranty ..................................................................................................................................................................18-20
Parts Ordering / Service..................................................................................................................................Back Page
TABLE OF CONTENTS
INTRODUCTION
Page 3 — English
DANGER:
Carbon Monoxide. Using a generator indoors CAN KILL
YOU IN MINUTES.
Generator exhaust contains high levels of carbon mon-
oxide (CO), a poisonous gas you cannot see or smell. If
you can smell the generator exhaust, you are breathing
CO. But even if you cannot smell the exhaust, you could
be breathing CO.
Never use a generator inside homes, garages, crawl-
spaces, or other partly enclosed areas. Deadly levels
of carbon monoxide can build up in these areas. Us-
ing a fan or opening windows and doors does NOT
supply enough fresh air.
ONLY use a generator outdoors and far away from
open windows, doors, and vents. These openings
can pull in generator exhaust.
Even when you use a generator correctly, CO may leak
into the home. ALWAYS use a battery-powered or bat-
tery-backup CO alarm in the home.
If you start to feel sick, dizzy, or weak after the generator
has been running, move to fresh air RIGHT AWAY. See a
doctor. You could have carbon monoxide poisoning.
WARNING:
Read and understand all instructions. Failure to follow
all instructions listed below may result in electrocution,
fire, and/or carbon monoxide poisoning, which will cause
death or serious injury.
DANGER:
National Electric Code requires generator to be grounded
to an approved earth ground. Before using the ground
terminal, consult a qualified electrician, electrical inspec-
tor, or local agency having jurisdiction for local codes
or ordinances that apply to the intended use of the
generator.
SAVE THESE INSTRUCTIONS
This manual contains important instructions that should be
followed during installation and maintenance of the genera-
tor and batteries.
Do not connect to a building’s electrical system unless
the generator and transfer switch have been properly
installed and the electrical output has been verified by a
qualified electrician.
Do not allow children or untrained individuals to use this
unit.
Never start or run the engine inside a closed or partially
enclosed area. Breathing exhaust fumes will kill you.
Keep all bystanders, children, and pets at least 10 feet
away.
Wear sturdy and dry shoes or boots. Do not operate while
barefoot.
Do not operate generator when you are tired or under the
influence of drugs, alcohol, or medication.
Keep all parts of your body away from any moving parts
and all hot surfaces of the unit.
Do not touch bare wire or receptacles.
Do not use generator with electrical cords which are
worn, frayed, bare, or otherwise damaged.
Before storing, allow the engine to cool and drain fuel
from the unit.
Do not operate or store the generator in rain, snow, or
wet weather.
Store the generator in a well-ventilated area with the
fuel tank empty. Fuel should not be stored near the
generator.
Empty fuel tank, close fuel valve, and restrain the unit
from moving before transporting in a vehicle.
Allow engine to cool for five minutes before refueling.
To reduce the risk of fire and burn injury, handle fuel with
care. It is highly flammable.
Do not smoke while handling fuel.
Store fuel in a container approved for gasoline.
Position the unit on level ground, stop engine, and allow
to cool before refueling.
Loosen fuel cap slowly to release pressure and to keep
fuel from escaping around the cap.
Tighten the fuel cap securely after refueling.
Wipe spilled fuel from the unit.
Never attempt to burn off spilled fuel under any circum-
stances.
Generators vibrate in normal use. During and after the
use of the generator, inspect the generator as well as
extension cords and power supply cords connected to
it for damage resulting from vibration. Have damaged
items repaired or replaced as necessary. Do not use plugs
or cords that show signs of damage such as broken or
cracked insulation or damaged blades.
For power outages, permanently installed stationary gen-
erators are better suited for providing back-up power to
the home. Even a properly connected portable generator
can become overloaded. This may result in overheating
or stressing the generator components, possibly leading
to generator failure.
IMPORTANT SAFETY INSTRUCTIONS
Page 4 — English
WARNING:
When this generator is used to supply a building
wiring system: generator must be installed by a quali-
fied electrician and connected to a transfer switch as
a separately derived system in accordance with NFPA
70, National Electrical Code. The generator shall be
connected through a transfer switch that switches all
conductors other than the equipment grounding con-
ductor. The frame of the generator shall be connected to
an approved grounding electrode. Failure to isolate the
generator from power utility can result in death or injury
to electric utility workers.
Do not use this generator to provide power for emergency
medical equipment or life support devices.
This generator has a neutral bonded condition. This
means the neutral conductor is electrically connected to
the frame of the machine.
Exhaust contains poisonous carbon monoxide, a color-
less, odorless gas. Breathing exhaust can cause loss
of consciousness and can lead to death. If running in a
confined or partially-enclosed area, the air may contain
a dangerous amount of carbon monoxide. To keep ex-
haust fumes from building up, always provide adequate
ventilation.
Always use a battery-powered carbon monoxide detec-
tor when running the generator. If you begin to feel sick,
dizzy, or weak while using the generator, shut it off and
get to fresh air immediately. See a doctor. You may have
carbon monoxide poisoning.
Place the generator on a flat, stable surface with a slope
of no more than 4°.
Operate in a well-ventilated, well-lit area isolated from
working areas to avoid noise interference.
Operating the generator in wet conditions could result in
electrocution. Keep the unit dry.
Keep the generator a minimum of 3 feet away from all
types of combustible material.
Do not operate generator near hazardous material.
Do not operate generator at a gas or natural gas filling
station.
Do not touch the muffler or cylinder during or immediately
after use; they are HOT and will cause burn injury.
Do not allow the generator’s gas tank to overflow when
filling. Fill to 1 in. below the top neck of the gasoline tank
to allow for fuel expansion. Do not cover the fuel tank cap
when the engine is running. Covering the fuel tank cap
during use may cause engine failure and/or damage to
the tool.
Do not smoke when filling the generator with gasoline.
Shut down the engine and allow to cool completely before
adding gasoline or lubricant to the generator.
Do not remove the oil dipstick or the fuel tank cap when
the engine is running.
Pay close attention to all safety labels located on the
generator.
Keep children a minimum of 10 feet away from the gen-
erator at all times.
The unit operates best in temperatures between 23°F and
104°F with a relative humidity of 90% or less.
Specific modifications for high-altitude performance are
needed if the generator will always be operated at alti-
tudes above 5,000 feet. Contact your nearest authorized
service center for more information and to have these
modifications performed.
Operating voltage and frequency requirement of all
electronic equipment should be checked prior to plug-
ging them into this generator. Damage may result if the
equipment is not designed to operate within a +/- 10%
voltage variation, and +/- 3 hz frequency variation from
the generator name plate ratings. To avoid damage, al-
ways have an additional load plugged into the generator
if solid state equipment (such as a television set) is used.
A power line conditioner is recommended for some solid
state applications.
For outdoor use only.
Save these instructions. Refer to them frequently and use
them to instruct others who may use this product. If you
loan someone this product, loan them these instructions
also.
Use only authorized replacement parts and accessories
and follow instructions in the Maintenance section of this
manual. Use of unauthorized parts or failure to follow
maintenance instructions may create a risk of shock or
injury.
Maintain the unit per maintenance instructions in this
Operator’s Manual.
Inspect the unit before each use for loose fasteners, fuel
leaks, etc. Replace damaged parts.
IMPORTANT SAFETY INSTRUCTIONS
SPECIFIC SAFETY RULES
Page 5 — English
The following signal words and meanings are intended to explain the levels of risk associated with this product.
SYMBOL SIGNAL MEANING
DANGER:
Indicates an imminently hazardous situation, which, if not avoided, will result
in death or serious injury.
WARNING:
Indicates a potentially hazardous situation, which, if not avoided, could result
in death or serious injury.
CAUTION:
Indicates a potentially hazardous situation, which, if not avoided, may result in
minor or moderate injury.
CAUTION:
(Without Safety Alert Symbol) Indicates a situation that may result in property
damage.
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper inter-
pretation of these symbols will allow you to operate the product better and safer.
SYMBOL NAME DESIGNATION/EXPLANATION
Safety Alert Indicates a potential personal injury hazard.
Read Operator’s Manual
To reduce the risk of injury, user must read and understand
operator’s manual before using this product.
Wet Conditions Alert Do not expose to rain or use in damp locations.
Electric Shock
Failure to use in dry conditions and to observe safe practices can
result in electric shock.
Toxic Fumes
Running generator gives off carbon monoxide, an odorless, color-
less, poison gas. Breathing carbon monoxide can cause nausea,
fainting, or death.
Fire/Explosion
Fuel and its vapors are extremely flammable and explosive. Fire
or explosion can cause severe burns or death.
Hot Surface
To reduce the risk of injury or damage, avoid contact with any hot
surface.
Lifting Hazard
To reduce the risk of serious injury, avoid attempting to lift the
generator alone.
Ground
Consult with local electrician to determine grounding requirements
before operation.
Electrocution
Failure to properly ground generator can result in electrocution,
especially if the generator is equipped with a wheel kit.
SYMBOLS
Page 6 — English
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper
interpretation of these symbols will allow you to operate the product better and safer.
SYMBOL NAME DESIGNATION/EXPLANATION
V Volts Voltage
A Amperes Current
Hz Hertz Frequency (cycles per second)
W Watt Power
hrs Hours Time
gal Gallon Volume
qt Quart Volume
SYMBOLS
SAFETY LABELS
The information below can be found on the generator. For
your safety, please study and understand all of the labels
before starting the generator.
If any of the labels come off the unit or become hard to read,
contact an authorized service center for replacement.
You WILL be KILLED or SERIOUSLY HURT if you do not
follow the Operator’s Manual instructions.
Risk of Fire. Do not add fuel while the product is operat-
ing.
Generator is a potential source of electric shock. Do not
expose to moisture, rain, or snow. Do not operate with
wet hands or feet.
Exhaust contains poisonous carbon monoxide gas that
can cause unconsciousness or DEATH. Operate in well-
ventilated, outdoor areas away from open windows or
doors.
Failure to properly ground generator can result in elec-
trocution, especially if the generator is equipped with a
wheel kit.
Do not expose to rain or use in damp locations.
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a
poison you cannot see or smell.
NEVER use inside a home or garage, EVEN IF doors and
windows are open.
Only use OUTSIDE and far away from windows, doors,
and vents.
Page 7 — English
SYMBOLS
FUEL WARNING
No smoking when filling with gasoline. Do not overfill. Full level
is 1 in. below the top of the fuel neck. Stop the engine for five
minutes before refueling to avoid the heat from the muffler
igniting fuel vapors.
ENGINE LUBRICANT WARNING
You must add lubricant before first operating the generator.
The oil reservoir capacity is 20 oz. Always check the lubricant
level before each operation. The lubricant level should always
register between the hatched areas on the dipstick.
GROUNDING WARNING
National Electric Code requires generator to be grounded to an approved earth ground.
HOT SURFACE WARNING
Do not touch the muffler or aluminum cylinder of the engine. They are very HOT and will cause
severe burns. Don’t put any flammable or combustible materials in the direct path of the exhaust.
Page 8 — English
ELECTRIC MOTOR LOADS
It is characteristic of common electric motors in normal operation to draw up to six times their running current while start-
ing. This table may be used to estimate the watts required to start “Code G” electric motors; however, if an electric motor
fails to start or reach running speed, turn off the appliance or tool immediately to avoid equipment damage. Always check
the requirements of the tool or appliance being used compared to the rated output of the generator.
Motor Size (H.P.) Running Watts
Watts Required to Start Motor
Repulsion Induction Capacitor Split Phase
1/8 275 600 850 1200
1/6 275 600 850 2050
1/4 400 850 1050 2400
1/3 450 975 1350 2700
1/2 600 1300 1800 3600
3/4 850 1900 2600
1 1100 2500 3300
CAUTION:
Operating voltage and frequency requirement of all
electronic equipment should be checked prior to plug-
ging them into this generator. Damage may result if the
equipment is not designed to operate within a +/- 10%
voltage variation, and +/- 3 hz frequency variation from
the generator name plate ratings. To avoid damage, al-
ways have an additional load plugged into the generator
if solid state equipment (such as a television set) is used.
A power line conditioner is recommended for some solid
state applications.
GROUND FAULT CIRCUIT INTERRUPTER
See Figure 1.
The 20 amp, 120 volt receptacles on the generator are protect-
ed by a Ground Fault Circuit Interrupter (GFCI), which guards
ELECTRICAL
against the hazards of ground fault currents. An example of
ground fault current is the current that would flow through a
person who is using an appliance with faulty insulation and,
at the same time, is in contact with an electrical ground such
as a plumbing fixture, wet floor, or earth.
GFCI receptacles do not protect against short circuits, over-
loads, or shocks.
The GFCI receptacles can be tested with the TEST and
RESET buttons.
To test:
Depress the TEST button. This should cause the Reset
button to pop out.
To restore power, depress the RESET button.
Perform this test monthly to ensure proper operation of the
GFCI. If the generator is stored outdoors, unprotected from
the weather, test the GFCI receptacle before each use.
EXTENSION CORD CABLE SIZE
Refer to the table below to ensure the cable size of the extension cords you use are capable of carrying the required load.
Inadequate size cables can cause a voltage drop, which can burn out the appliance and overheat the cord.
Current in
Amperes
Load in Watts Maximum Allowable Cord Length
At 120V At 240V #8 Wire #10 Wire #12 Wire #14 Wire #16 Wire
2.5 300 600 1000 ft. 600 ft. 375 ft. 250 ft.
5 600 1200 500 ft. 300 ft. 200 ft. 125 ft.
7.5 900 1800 350 ft. 200 ft. 125 ft. 100 ft.
10 1200 2400 250 ft. 150 ft. 100 ft. 50 ft.
15 1800 3600 150 ft. 100 ft. 65 ft.
20 2400 4800 175 ft. 125 ft. 75 ft.
25 3000 6000 150 ft. 100 ft.
30 3600 7200 125 ft. 65 ft.
40 4800 9600 90 ft.
Page 9 — English
GENERATOR CAPACITY
Make sure the generator can supply enough continuous (run-
ning) and surge (starting) watts for the items you will power
at the same time. Follow these simple steps.
1. Selecttheitemsyouwillpoweratthesametime.
2. Totalthecontinuous(running)wattsoftheseitems.This
is the amount of power the generator must produce to
keep the items running. See the wattage reference chart
at right.
3. Estimatehowmanysurge(starting)wattsyouwillneed.
Surge wattage is the short burst of power needed to start
electric motor-driven tools or appliances such as a circular
saw or refrigerator. Because not all motors start at the
same time, total surge watts can be estimated by adding
only the item(s) with the highest additional surge watts to
the total rated watts from step 2.
Example:
Tool or Appliance
Continuous
(Running) Watts
Surge
(Starting) Watts
Window AC,
10,000 BTU
1200 1800
Refrigerator 700 2200
1/3 HP Well Pump 1000 2000
27 in. Television 500 0
Light (75 Watts) 75 0
3475 Total
Running Watts
2200 Highest
Surge Watts
Total Continuous (Running) Watts 3475
Plus Highest Additional Surge Watts + 2200
Equals Total Generator Output Required 5675
POWER MANAGEMENT
To prolong the life of the generator and attached devices,
it is important to take care when adding electrical loads to
the generator. There should be nothing connected to the
generator outlets before starting its engine. The correct and
safe way to manage generator power is to sequentially add
loads as follows:
1. With nothing connected to the generator, start the engine
as described later in this manual.
2. Plug in and turn on the first load, preferably the largest
load you have.
3. Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly).
4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
Never add more loads than the generator capacity. Take
special care to consider surge loads in generator capacity
as previously described.
CAUTION:
Do not overload the generator’s capacity. Exceeding the
generator’s wattage/amperage capacity can damage the
generator and/or electrical devices connected to it.
Application/Equipment
Estimated
Run Watts
Estimated
Starting
Watts
Emergency / Home Standby
Clock Radio 50 50
Lights (qty. 4 x 75 W) 300 300
Refrigerator 700 2200
Furnace Fan 800 2350
Water Well Pump 1000 1500
Microwave 1000 1000
Sump Pump 1050 2200
Electric Range (per element) 2100 2100
Job Site
ElectricDrill−1/2HP 600 900
AirlessSprayer−1/3HP 600 1200
Quartz Halogen Work Light 1000 1000
Reciprocating Saw 960 1920
AirCompressor−1HP 1600 4500
CircularSaw−7-1/4in. 1400 2300
Planer/Jointer−6in 1800 1800
MiterSaw−10in. 1800 1800
TableSaw/RadialArmSaw−10in. 2000 2000
*Wattages listed are approximate. Check tool or appliance for actual wattage.
ELECTRICAL
Page 10 — English
PRODUCT SPECIFICATIONS
ENGINE
Engine Type ............................ 4 Stroke, OHC (Chain Drive)
Bore x Stroke .............................................67 mm x 60 mm
Cooling System ...................................................Forced Air
Compression Ratio ......................................................8:5:1
Starting System ......................................................... Recoil
Ignition System ............................................................T.C.I.
Spark Plug ................... NGK BR-6HS or Champion RL86C
Engine Lubricant Volume........................................... 20 oz.
Fuel Volume ................................................................ 4 gal.
GENERATOR
Rated Voltage .....................................................120V/240V
Rated Amps ................................................... 30.4 A/15.2 A
Rated Running Watts* ............................................3,650 W
Rated Starting Watts ..............................................4,550 W
Rated Frequency ........................................................60 Hz
DIMENSIONS
Length ..................................................................21-1/2 in.
Width ....................................................................16-1/2 in.
Height ......................................................................... 24 in.
Weight .................................................................... 159 lbs.
KNOW YOUR GENERATOR
See Figure 2.
The safe use of this product requires an understanding of the
information on the product and in this operator’s manual as
well as a knowledge of the project you are attempting. Before
use of this product, familiarize yourself with all operating
features and safety rules.
AC CIRCUIT BREAKER
The circuit breaker is provided to protect the generator
against electrical overload.
AIR FILTER
The air filter helps to limit the amount of dirt and dust drawn
into the unit during operation.
CHOKE LEVER
The choke lever is used when starting the engine.
CORD RETAINERS
Use the cord retainers to prevent plugs from being acciden-
tally pulled out of the 120 volt receptacles.
ENGINE SWITCH
The engine switch is used in combination with the recoil
starter grip to start the generator. It is also used to turn the
generator off.
FUEL TANK
The fuel tank has a capacity of 4 gallons.
FUEL VALVE
The flow of fuel through the generator is controlled by the
position of the fuel valve.
GROUND TERMINAL
The ground terminal is used to assist in properly ground-
ing the generator to help protect against electrical shock.
Consult with a local electrician for grounding requirements
in your area.
OIL CAP/DIPSTICK
Remove the oil fill cap to check and add lubricant to the
generator when necessary.
OIL DRAINAGE BOLT
When changing the engine lubricant, the oil drainage bolt is
loosened to allow old engine lubricant to be drained.
RECEPTACLES
Your generator has the following single phase, 60 Hz outlets:
four 120 Volt AC, 20 Amp GCFI receptacles, and one 240
Volt AC, 20 Amp receptacle. These can be used for operat-
ing appropriate appliances, electrical lighting, tools, and
motor loads.
RECOIL STARTER GRIP
The recoil starter grip is used (along with the engine switch)
to start the generator’s engine.
FEATURES
*Rated running watts determined by PGMA Standard G200
Page 11 — English
UNPACKING
This product requires assembly.
Carefully cut the box down the sides then remove the
machine and any accessories from the box. Make sure
that all items listed in the packing list are included.
NOTE: This machine is heavy and requires a minimum of
two people to lift. To avoid back injury, lift with your legs
and not your back.
WARNING:
Do not use this product if any parts on the Loose Parts List
are already assembled to your product when you unpack
it. Parts on this list are not assembled to the product by
the manufacturer and require customer installation. Use
of a product that may have been improperly assembled
could result in serious personal injury.
Inspect the unit carefully to make sure no damage oc-
curred during shipping.
Do not discard the packing material until you have carefully
inspected and satisfactorily operated the product.
If any parts are damaged or missing, please call
1-800-242-4672 for assistance.
LOOSE PARTS LIST
See Figure 3.
Key
No. Description Qty.
1 Bolt (3/8-16 x 4-1/4 in.) .......................................2
2 Washer (3/8 in.) ....................................................2
3 Spacer (.38 ID) .....................................................2
4 Wheel ...................................................................2
5 Lock Nut (3/8-16) .................................................2
6 Handle Lock Pin ..................................................1
7 Lanyard ................................................................1
8 Lock Nut (1/4-20) .................................................2
9 Washer (1/4 in.) ....................................................2
10 Rubber Foot ........................................................2
11 Bolt (1/4-20 x 1-1/2 in.) .......................................2
12 Flange Nut (5/16-18) ............................................2
13 Washer (5/16 in.) ..................................................4
14 Bolt (5/16-18 x 1 in.) ............................................2
15 Frame Support ....................................................1
16 Engine Lubricant..................................................1
Operator’s Manual (not shown) ...........................1
WARNING:
If any parts are damaged or missing do not operate this
product until the parts are replaced. Use of this product
with damaged or missing parts could result in serious
personal injury.
WARNING:
Do not attempt to modify this product or create acces-
sories not recommended for use with this product. Any
such alteration or modification is misuse and could result
in a hazardous condition leading to possible serious per-
sonal injury.
WARNING:
Do not attempt to operate the generator until assembly
is complete. Failure to comply could result in possible
serious personal injury.
TOOLS NEEDED
See Figure 4.
The following tools (not included or drawn to scale) are
needed for assembly:
7/16 in., 1/2 and 5/8 in. socket wrench
7/16 in., 1/2 and 5/8 in. combination wrench
NOTE: Do not put fuel or lubricant in the generator before
installing the feet, frame support, and wheels.
INSTALLING FEET ON THE FRAME SUPPORT
See Figure 5.
Locate the following items:
2 rubber feet
2 lock nuts (1/4-20)
2 washers (1/4 in.)
2 bolts (1/4-20 x 1-1/2 in.)
Insert bolt through foot, then through frame support as
shown.
Thread washer over the bolt, then install nut. Tighten nut
securely.
NOTE: Be careful not to overtighten so that foot mate-
rial collapses.
Repeat with remaining foot.
INSTALLING THE FRAME SUPPORT
See Figure 5.
Install the frame support on the bottom of the generator
frame on the same side as the handle.
Locate the following items:
Frame support
2 flange nuts (5/16-18)
2 washers (5/16 in.)
2 bolts (5/16-18 x 1 in.)
Raise the end of the generator where the recoil starter is
located high enough to gain access to the frame bottom;
securely position props underneath to support.
Align the holes on the frame support with the holes on
the generator frame.
ASSEMBLY
Page 12 — English
DANGER:
Carbon Monoxide. Using a generator indoors CAN KILL
YOU IN MINUTES.
Generator exhaust contains high levels of carbon mon-
oxide (CO), a poisonous gas you cannot see or smell. If
you can smell the generator exhaust, you are breathing
CO. But even if you cannot smell the exhaust, you could
be breathing CO.
Never use a generator inside homes, garages, crawl-
spaces, or other partly enclosed areas. Deadly levels
of carbon monoxide can build up in these areas. Us-
ing a fan or opening windows and doors does NOT
supply enough fresh air.
ONLY use a generator outdoors and far away from
open windows, doors, and vents. These openings
can pull in generator exhaust.
Even when you use a generator correctly, CO may
leak into the home. ALWAYS use a battery-powered or
battery-backup CO alarm in the home.
If you start to feel sick, dizzy, or weak after the generator
has been running, move to fresh air RIGHT AWAY. See
a doctor. You could have carbon monoxide poisoning.
Slide a washer on the bolt, then insert the bolt through the
hole in the generator frame so it extends down through
the frame support.
Slide a washer on the bolt, then install flange nut and
tighten securely.
Repeat on other side.
INSTALLING THE WHEELS
See Figure 6.
Wheels are provided to assist in moving the generator to
the desired location and should be installed on the side
opposite the handle.
Locate the following items:
2 Bolts (3/8-16 x 4-1/4 in.)
2 Washers (3/8 in.)
2 Spacers (.38 ID)
2 Wheels
2 Lock Nuts (3/8-16)
Raise the end of the generator opposite the handle
high
enough to gain access to the frame bottom; securely
position props underneath to support.
Insert a wheel spacer into the center of the wheel.
Place a washer on the bolt, then slide bolt through the
wheel.
Slide the bolt through the U-bracket frame on generator.
Install nut on bolt and tighten securely.
Repeat the process on the other side to install second
wheel.
SECURING THE HANDLE
See Figures 7 - 8.
Locate the following items:
Handle lock pin
Lanyard
Attach the lanyard to the handle lock pin and the handle
as shown in figure 7.
Extend the handle, then insert the pin through the hole
in the handle and the generator frame to secure handle
in place.
CAUTION:
Do not attempt to lift the unit by the handle assembly. If
it is necessary to lift the generator, always grasp by the
frame. Use proper lifting techniques to avoid back injury.
RELEASING THE HANDLE
Remove the handle lock pin and lower the handle to the
down position.
ASSEMBLY
OPERATION
DANGER:
Failure to properly ground generator can result in elec-
trocution, especially if the generator is equipped with a
wheel kit. National Electric Code requires generator to be
properly grounded to an approved earth ground. Call an
electrician for local grounding requirements.
WARNING:
Do not allow familiarity with this product to make you
careless. Remember that a careless fraction of a second
is sufficient to inflict serious injury.
WARNING:
Do not use any attachments or accessories not
recommended by the manufacturer of this product. The
use of attachments or accessories not recommended
can result in serious personal injury.
APPLICATIONS
This generator is designed to supply electrical power for
operating compatible electrical lighting, appliances, tools,
and motor loads.
Page 13 — English
BEFORE OPERATING THE UNIT
Only use OUTSIDE and far away from windows, doors,
and vents.
NEVER use inside a home or garage, EVEN IF doors and
windows are open.
Always position the generator on a flat firm surface.
CAUTION:
Attempting to start the engine before it has been properly
filled with lubricant will result in equipment failure.
CHECKING/ADDING LUBRICANT
See Figure 9.
Engine lubricant has a major influence on engine perfor-
mance and service life. For general, all-temperature use,
SAE 10W-30 is recommended. Always use a 4-stroke motor
lubricant that meets or exceeds the requirements for API
service classification SJ.
NOTE: Non-detergent or 2-stroke engine lubricants will
damage the engine and should not be used.
Unscrew the oil cap/dipstick and remove.
Wipe dipstick clean and re-seat in hole; do not re-thread.
Remove dipstick again and check lubricant level. Lubricant
level should fall between the hatched areas on the dipstick.
If level is low, add engine lubricant until the fluid level rises
to the upper portion of the dipstick.
Replace and secure the oil cap/dipstick.
CHECKING/ADDING FUEL
See Figure 10.
Remove the fuel cap.
Fill the fuel tank to 1 in. below the top of the fuel neck.
Replace and secure the fuel cap.
NOTE: Always use unleaded gasoline with a pump octane
rating of 86 or higher. Never use old, stale, or contaminated
gasoline, and do not use an oil/gas mixture. Do not allow
dirt or water into the fuel tank.
USING FUEL STABILIZER
Fuel gets old, oxidizes, and breaks down over time. Adding
a fuel stabilizer (not included) extends the usable life of fuel
and helps prevent deposits from forming that can clog the
fuel system. Follow fuel stabilizer manufacturer’s directions
for correct ratio of stabilizer to fuel.
Add stabilizer to fuel tank, then fill with gasoline following
previous instructions.
NOTE: Fuel stabilizer and gasoline can be mixed prior
to filling the tank by using a gas can or other approved
fuel container and shaking gently to combine.
Replace and secure the fuel tank cap.
Start and run the engine for at least 5 minutes to allow
stabilizer to treat the entire fuel system.
OXYGENATED FUELS
DO NOT USE E85 FUEL. IT WILL VOID YOUR WARRANTY.
NOTE: Fuel system damage or performance problems re-
sulting from the use of an oxygenated fuel containing more
than the percentages of oxygenates stated below are not
covered under warranty.
Ethanol. Gasoline containing up to 10% ethanol by volume
(commonly referred to as E10) is acceptable. E85 is not.
CAUTION:
On a level surface with the engine off, check the lubricant
level before each use of the generator.
STARTING THE ENGINE
See Figures 11 - 13.
NOTE: If location of generator is not level, the unit may not
start or may shut down during operation.
Unplug all loads from the generator.
Turn the fuel valve to the ON position.
Move the choke lever right to the START position.
NOTE: If engine is warm or the temperature is above
50˚F,movethechokeleverlefttotheRUNposition.
Put the engine switch in the ON ( I ) position.
Pull the recoil starter grip until the engine runs (a maximum
of 6 times).
NOTE: Do not allow the grip to snap back after starting;
return it gently to its original place.
Allow the engine to run for 30 seconds, then move the
choke lever left to the RUN position.
OPERATION
Page 14 — English
WARNING:
When servicing, use only identical replacement parts.
Use of any other parts may create a hazard or cause
product damage.
WARNING:
Always wear eye protection with side shields marked to
comply with ANSI Z87.1. Failure to do so could result in
objects being thrown into your eyes, resulting in possible
serious injury.
Only the parts shown on the parts list are intended to be
repaired or replaced by the customer. All other parts should
be replaced at an authorized service center.
GENERAL MAINTENANCE
Keep the generator in a clean and dry environment where it
is not exposed to dust, dirt, moisture, or corrosive vapors.
Do not allow the cooling air slots in the generator to become
clogged with foreign material such as leaves, etc.
Do not use a garden hose to clean the generator. Water en-
tering the fuel system or other internal parts of the unit can
cause problems that will decrease the life of the generator.
To clean the unit:
Use a soft bristle brush and/or vacuum cleaner to loosen
and remove dirt and debris.
Clean air vents with low pressure air that does not exceed
25 psi.
Wipe the exterior surfaces of the generator with a damp
cloth.
CHECKING/CLEANING AIR FILTER
See Figure 14.
For proper performance and long life, keep air filter clean.
Release latches on left side of air filter cover. Remove
cover and set aside.
Remove the filter element.
If the filter element is dirty, clean with warm, soapy water.
Rinse and let dry.
Apply a light coat of engine lubricant to the element, then
squeeze it out.
Replace the element in the air filter unit.
Replace the air filter cover and latch to secure.
NOTE: Do not run the generator without the air filter. Rapid
engine wear will result.
CHANGING ENGINE LUBRICANT
See Figure 15.
Remove the oil cap/dipstick.
Place a container underneath the oil drainage bolt to
collect used lubricant as it drains.
Unscrew the oil drainage bolt and remove.
Allow lubricant to drain completely.
Reinstall the oil drainage bolt and tighten securely.
Refill with lubricant following the instructions in the
Checking/Adding Lubricant section.
Reinstall the oil cap/dipstick.
NOTE: Used lubricant should be disposed of at an ap-
proved disposal site. See your local oil retailer for more
information.
STOPPING THE ENGINE
See Figures 11 - 12.
To stop the engine under normal operating conditions:
Remove any load from the generator.
Turn the fuel valve to the OFF position.
Put the engine switch in the OFF ( O ) position.
To stop the engine in an emergency situation:
Put the engine switch in the OFF ( O ) position.
MOVING THE GENERATOR
Turn the engine switch OFF ( O ). Disconnect any equip-
ment that is plugged into the generator.
Turn the fuel valve to the OFF position.
Allow 30 minutes of “cool down” time before storing the
machine.
For security, insert the pin to secure the handle before
transporting.
Tilt the machine away from you until it balances on the
wheels, then roll the machine to the desired location.
OPERATION
MAINTENANCE
Page 15 — English
SPARK PLUG MAINTENANCE
See Figure 16.
The spark plug must be properly gapped and free of deposits
in order to ensure proper engine operation. To check:
Remove the spark plug cap.
Clean any dirt from around base of spark plug.
Remove spark plug using wrench (not included).
Inspect spark plug for damage, and clean with a wire
brush before reinstalling. If insulator is cracked or
chipped, spark plug should be replaced.
NOTE: If replacing, use the following recommended
spark plugs or equivalent: NGK BR-6HS or Champion
RL86C.
Measurepluggap.Thecorrectgapis0.028−0.031in.
(0.7-0.8 mm). To widen gap, if necessary, carefully bend
the ground (top) electrode. To lessen gap, gently tap
ground electrode on a hard surface.
Seat spark plug in position; thread in by hand to prevent
cross-threading.
Tighten with wrench to compress washer. If spark plug
is new, use 1/2 turn to compress washer appropriate
amount. If reusing old spark plug, use 1/8 to 1/4 turn for
proper washer compression.
NOTE: An improperly tightened spark plug will become
very hot and could damage the engine.
CLEANING THE EXHAUST PORT AND
MUFFLER
Depending on the type of fuel used, the type and amount of
lubricant used, and/or your operating conditions, the exhaust
port and muffler may become blocked with carbon deposits.
If you notice a power loss with your gas-powered products,
you may need to remove these deposits to restore perfor-
mance. We highly recommend that only qualified service
technicians perform this service.
SPARK ARRESTOR
See Figure 17.
Inspect the spark arrestor for breaks or holes. Replace
if necessary. To purchase a replacement spark arrestor
contact Homelite customer service at 1-800-242-4672.
Use a brush to remove carbon deposits from the spark
arrestor screen as needed.
DRAINING FUEL TANK/CARBURETOR
See Figures 18 - 19.
To help prevent gum deposits in the fuel system, drain the
fuel from the tank and carburetor before storing.
DRAINING THE FUEL TANK
Turn the engine switch OFF ( O ).
Turn the fuel valve to the OFF position.
Remove the fuel line from the petcock by squeezing the
ends of the retaining clip and sliding the fuel line off.
Install one end of a drain line over the petcock, and place
the other end in a fuel container large enough to catch
the fuel being drained from the tank.
Turn the fuel valve to the ON position.
When the fuel has drained from the tank, close the fuel
valve and reinstall fuel line on petcock.
DRAINING THE CARBURETOR
Turn the engine switch OFF ( O ).
Turn the fuel valve to the OFF position.
Position a suitable container under the carburetor drain
screw to catch fuel; loosen the screw.
Allow fuel to drain completely into container.
Retighten drain screw.
NOTE: Consult hazardous waste management guidelines in
your area for the proper way to dispose of used fuel.
REPLACING FUEL FILTER
See Figure 20.
Occasionally the fuel filter may become clogged and need
replacing. To purchase a replacement fuel filter contact Husky
customer service at 1-800-242-4672.
NOTE: Fuel tank must be empty before replacing fuel filter.
Run unit until tank is empty, if needed, or inspect filter prior
to fill-up.
To replace:
Turn the fuel valve to the OFF position.
Remove the fuel line from both sides of the filter by
squeezing the ends of the retaining clip with pliers.
Slide the fuel line off.
Replace with new fuel filter.
Reinstall fuel lines to new fuel filter.
Turn the fuel valve to the ON position.
TRANSPORTING
Turn engine switch OFF ( O ).
Turn the fuel valve to the OFF position.
Make sure engine and exhaust of unit is cool.
Keep unit level to prevent fuel spillage.
Do not drop or strike unit or place under heavy objects.
MAINTENANCE
Page 16 — English
STORAGE
When preparing the generator for storage, allow the unit to cool completely then follow the guidelines below.
STORAGE TIME PRIOR TO STORING
Less than 2 months Drain gasoline from tank and dispose of in a suitable container according to state and local
ordinances.
2 months to 1 year Drain fuel from carburetor.
Drain gasoline from tank and dispose of in a suitable container according to state and local
ordinances.
1 year or more Drain fuel from the carburetor.
Remove spark plug.
Drain gasoline from tank and dispose of in a suitable container according to state and local
ordinances.
Put a tablespoon of engine oil into the spark plug cylinder. Turn the engine slowly with the pull
rope to distribute the oil.
Reinstall spark plug.
Change engine lubricant.
After removal from storage:
Fill with fresh gasoline.
MAINTENANCE SCHEDULE
Before
each use
After 1st month
or 20 hours of
operation
Every 3 months
or 50 hours of
operation
Every 6 months
or 100 hours
of operation
Every year or
after 300 hours
of operation
Check Engine Lubricant
Change Engine Lubricant
Check Air Filter
Clean Air Filter
Change Air Filter
Check/Adjust Spark Plug
Replace Spark Plug
Check/Adjust Idle Speed
Check/Adjust Valve
Clearance*
Clean Fuel Tank and
Filter*
Check Fuel Tube
Replace Fuel Filter
* These items should only be carried out by an authorized service center.
NOTE: Maintenance should be performed more frequently when generator is used in dusty areas.
When generator has exceeded the maximum figures specified in the table, maintenance should still be cycled
according to the intervals of time or hours stated herein.
MAINTENANCE
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64

Homelite Portable Generator UT903611 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur
Ce manuel convient également à