NAPOLEON NZ7000 Manuel utilisateur

Catégorie
Poêles
Taper
Manuel utilisateur
FRENCH
PG. 49
W415-1676 / E / 05.17.21
ADD MANUAL TITLE
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030
Phone 1 (866) 820-8686 • www.napoleon.com • [email protected]
ADD SAFETY STANDARD INFORMATION
& EPA QUALIFICATION (IF APPLICABLE)
Product Name / Code
(MUST use title from Price Book)
ADD ____ ILLUSTRATED
ADD PRODUCT IMAGE
CSA / OMNI
/ INTERTEK
LOGO
SAFETY INFORMATION
- This heater can be very hot when burning.
- Combustible materials such as fi rewood, wet clothing, etc. placed
too close can catch fi re.
- Children and pets must be kept from touching the heater when it is
hot.
- The chimney must be sound and free of cracks. Before installing this
appliance, contact the local building or fi re authority and follow their
guidelines.
- Always operate this appliance with the door(s) or screen (where
applicable) tightly closed.
- Burn wood behind the log retainer directly on the fi rebricks.
- Do not use an elevated grate or otherwise raise the fi re.
- This appliance is designed to burn natural wood only. Higher
effi ciencies and lower emissions generally result when burning air
dried seasoned hardwoods, as compared to softwoods or to green
or freshly cut hardwoods.
- Do not start a fi re with chemicals or fl uids such as gasoline, engine
oil, etc.
- Do not burn trash or garbage, lawn clippings/waste, rubber,
waste petroleum products, paints or paint thinners/solvents, plastic,
materials containing asbestos, construction debris, railroad ties or
treated wood, manure or animal remains, salt water driftwood or
salted materials, unseasoned wood, coal, charcoal, coloured paper,
cardboard, plywood or particleboard. Burning these materials may
result in release of toxic fumes or render the appliance ineffective and
cause smoke.
- Do not let the appliance become hot enough for any part to glow
red.
If the information in these instructions are not followed exactly, a fi re
or explosion may result causing property damage, personal injury or
death. Please read the entire manual before you install and use your
appliance. This heater has not been tested with an unvented gas log
set. To reduce risk of fi re or injury, do not install an unvented gas log
set into the heater.
WARNING
!
ENGLISH
$10.00
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
FOR INDOOR USE ONLY
This wood appliance needs periodic inspection and repair. It is against United States federal regulations to operate this wood
appliance in a manner inconsistent with the operating instructions in this manual.
Wood Stoves ONLY
- At least 14 squares inches (90.3 square centimeters) of outside air
must be admitted to the room or directly to the appliance through a
4” (101.6mm) diameter pipe.
- KEEP THE STOVE TOP TEMPERATURE BELOW 700°F (371°C).
Attempts to achieve heat output rates that exceed design
specifications can result in steel distortion and damage.
IF INSTALLATION + OPERATION, ADD SERIAL
NUMBER LABEL HERE
IF SEPARATE MANUALS, ADD “PLACE
BARCODE LABEL ON THE OWNER’S MANUAL”
These appliances have been safety tested and listed by Intertek
Testing Services Ltd. as per the standards: ULC S610, UL 127 U.S.
*Only the NZ8000 is an EPA Low Mass Wood-burning Fireplace
Voluntary Program Phase 2 Emission Level Qualifi ed model.
(NZ8000 illustrated)
INSTALLATION AND
OPERATION MANUAL
High Country™ 7000 / 8000*
Low Mass Fireplace
W415-1676 / E / 05.17.21
EN
2
safety information
This appliance is hot when operated and can cause
severe burns if contacted.
Any changes or alterations to this appliance or its
controls can be dangerous and is prohibited.
Do not operate appliance before reading and
understanding operating instructions. Failure
to operate appliance according to operating
instructions could cause fi re or injury.
Before installing this appliance, contact the local
building or fi re authority and follow their guidelines.
This appliance must be installed by a qualifi ed
installer. Never try to repair or replace any part of the appliance unless instructions are given in this manual.
All other work should be done by a trained technician.
Risk of burns. The appliance should be turned off and cooled before servicing.
Do not operate without fully assembling all components. Do not install damaged, incomplete or substitute
components.
Do not let the appliance become hot enough for any part to glow red.
Risk of cuts and abrasions. Wear protective gloves, footwear and safety glasses during installation. Sheet
metal edges may be sharp.
All wiring should be done by a qualifi ed electrician and shall be in compliance with local codes. in the
absence of local codes, use the current CSA22.1 Canadian Electric Code in Canada or the current
National Electric Code ANSI/NFPA No. 70 in the United States.
If equipped, burning your appliance with the ash dump door ajar creates a fi re hazard that may result in
discolouration to the door, internal damage to the appliance or a house and/or chimney fi re.
Do not connect this appliance to a chimney fl ue serving another appliance.
Clothing or other fl ammable material should not be placed on or near the appliance. Objects placed in
front of the appliance must be kept a minimum of 48” (121.9cm) away from the front face of the appliance.
Due to high temperatures, the appliance should be located out of traffi c and away from furniture and
draperies.
Even after the appliance is off, it will remain hot for an extended period of time.
Any safety screen or guard removed for servicing must be replaced prior to operating the appliance.
Under no circumstances should this appliance be modifi ed.
This appliance must not be connected to a chimney fl ue pipe servicing a separate solid fuel burning
appliance.
Do not operate the appliance with the glass door removed, cracked or broken. Replacement of the glass
should be done by a licensed or qualifi ed service person.
Do not strike or slam shut the appliance glass door.
Only doors / optional fronts certifi ed with the appliance are to be installed on the appliance.
If the appliance is not properly installed, a house fi re may result. Do not expose the appliance to the
elements (ex. rain, etc.) and keep the appliance dry at all times. Wet insulation will produce an odour when
the appliance is used.
The chimney must be sound and free of cracks. Clean your chimney a minimum of twice a year and as
required.
Children and adults should be alerted to the hazards of high surface temperature and should stay away to
avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the same room as the appliance.
Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier
is recommended if there are at risk individuals in the house. To restrict access to an appliance or stove,
install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the
room and away from hot surfaces.
Ensure you have incorporated adequate safety measures to protect infants/toddlers from touching hot
surfaces.
Check with your local hearth specialty dealer for safety screens and hearth guards to protect children from
hot surfaces. These screens and guards must be fastened to the fl oor.
Keep the packaging material out of reach of children and dispose of the material in a safe manner. As with
all plastic bags, these are not toys and should be kept away from children and infants.
Do not start a fi re with chemicals or fl uids such as gasoline, engine oil, etc.
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
!
WARNING
!
WARNING
EN
W415-1676 / E / 05.17.21
3
safety information
!
WARNING
Your appliance requires periodic maintenance and cleaning. Failure to maintain your appliance may lead to smoke
spillage in your home.
Ashes must be disposed in a metal container with a tight lid and placed on a non-combustible surface well
away from the home or structure until completely cool.
Ensure clearances to combustibles are maintained when building a mantel or shelves above the appliance.
Elevated temperatures on the wall or in the air above the appliance can cause melting, discolouration or damage
to decorations, a TV or other electronic components.
For wood appliances:
Lower emissions generally result when burning air dried seasoned hardwoods, as compared to softwoods
or too green or freshly cut hardwoods. Burning wet unseasoned wood can cause excessive creosote
accumulation. When this is ignited it can cause a chimney fi re that may result in a serious house fi re.
This appliance is designed to burn natural wood only. Do not burn trash or garbage, lawn clippings /
waste, rubber, waste petroleum products, paints or paint thinners / solvents, plastic, materials containing
asbestos, construction debris, railroad ties or treated wood, manure or animal remains, salt water driftwood
or salted materials, unseasoned wood, coal, charcoal, coloured paper, gift wrapping, cardboard, plywood or
particleboard. Burning these materials may result in release of toxic fumes or render the appliance ineffective
and cause smoke.
Burn wood directly on the fi rebricks. Do not elevate grate or otherwise raise the fi re.
Do not store wood within appliance installation clearances or within the space required for re-fueling and
ash removal.
If equipped, the catalyst must be installed and in good working order. It is recommended that the catalyst
is inspected at least three times per heating season.
Add California Prop 65 warning
!
WARNING:
This product can expose you to chemicals including lead and lead compounds,
which are known to the State of California to cause cancer, and chemicals including carbon
monoxide, which are known to the State of California to cause birth defects or other reproduc-
tive harm. For more information, go to www.P65Warnings.ca.gov.
W415-1676 / E / 05.17.21
EN
4
table of contents
1.0 dimensions 5
2.0 general information 6
2.1 general instructions 7
2.2 features 8
2.3 this appliance 8
2.4 packing list 8
2.5 rating plate information 9
3.0 installation planning 10
3.1 location and clearances 10
3.1.1 ventilation openings 11
3.2 outside combustion air 11
3.2.1 outside combustion air operation 12
3.3 oor protection / ember strip and hearth
extensions 13
3.3.1 hearth extension 14
3.3.2 hearth examples 15
3.3.3 ue damper operation 16
4.0 installation 17
4.1 chimney 17
4.2 typical chimney installation 18
4.3 adding chimney sections 19
4.4 offset chimney installation 20
4.5 installing fl ashing and storm collar 21
4.6 air cooled chimney installation 21
5.0 framing 22
5.1 fi nishing material 23
5.2 minimum clearance to combustibles 24
5.3 minimum enclosure clearances 24
5.4 minimum mantel clearances 25
6.0 operation and adjustments 26
6.1 door & screen operation 26
6.2 door level adjustment 27
6.3 door glass replacement 29
6.4 screen replacement 30
6.5 balance weight adjustment 31
6.6 fi rebrick installation 32
6.7 smoke chamber insulation panel
replacement 33
Changes, other than editorial, are denoted by a vertical line in the margin
note:
7.0 selecting wood 34
8.0 operation 35
8.1 operating sounds and smells 35
8.2 starting a fi re 36
8.3 re extinguishers / smoke dectectors &
carbon monoxide detectors 36
8.4 starting a fi re (damper open) 37
8.5 smoking 38
8.6 reloading the appliance 38
9.0 maintenance 39
9.1 ash removal procedures 39
9.2 creosote formation and removal 39
9.3 run-away or chimney fi re 39
9.4 chimney cleaning 40
9.5 care of glass 40
10.0 replacement parts 41
10.1 NZ7000 overview 42
10.2 NZ7000 accessories 43
10.3 NZ8000 overview 44
10.4 NZ8000 accessories 45
11.0 troubleshooting 46
12.0 warranty 47
EN
W415-1676 / E / 05.17.21
5
dimensions
NZ8000 ILLUSTRATED
**
**
**
**
NZ8000 ILLUSTRÉ
FACEPLATE
80
13
16
"
2053mm
78
5
16
"
1989mm
6"
152mm
34
1
4
"
870mm
30
5
16
"
770mm
31
1
2
"
800mm
40
1
4
"
1023mm
1
3
16
"
31mm
57
3
8
"
1458mm
59
5
8
"
1514mm
61
13
16
"
1570mm
46
3
8
"
1178mm
16
11
16
"
425mm
12"
[ 305mm ]
NO SCREWS IN THIS AREA
SCREWS MUST NOT PENETRATE MORE THAN
1/2" (12.7mm) IN LENGTH IN THIS AREA
**
NZ7000 ILLUSTRATED
NZ8000 ILLUSTRATED
80
13
16
"
2053mm
78
5
16
"
1989mm
6"
152mm
25
1
8
"
639mm
31
1
8
"
791mm
30
5
16
"
770mm
31
1
2
"
800mm
1
3
16
"
30mm
46
3
8
"
1178mm
12"
[ 305mm ]
16
11
16
"
425mm
57
3
8
"
1458mm
59
5
8
"
1514mm
61
13
16
"
1570mm
**
**
**
**
****
**
**
1.0 dimensions
W415-1676 / E / 05.17.21
EN
6
general information
2.0 general information
Hearth, see “hearth
extension” section
Rating plate, see “rating
plate information”
section
Firebrick, see “firebrick
installation” section
Framing, see “framing”
section
Chimney, see “chimney
installation” section
Mantel, see “minimum mantel
clearances” section
Finishing, see “finishing”
section
EN
W415-1676 / E / 05.17.21
7
general information
!
WARNING
Before installing this appliance, contact the local building or fi re authority and follow their guidelines.
This appliance must be installed by a qualifi ed installer. Follow the installation directions. Do not operate
without fully assembling all components.
If this appliance is not properly installed, a house fi re may result.
Do not expose the appliance to the elements (ex. rain, etc.) and keep the appliance dry at all times. Wet
insulation will produce an odour when the appliance is used.
This appliance is hot when operated and can cause severe burns if contacted. Children and pets must be
kept from touching the appliance when it is hot. Contact your local authorized dealer/distributor for safety
screens that may be available for this product.
Combustible material such as fi rewood, wet clothing, etc. placed too close can catch fi re. Objects placed
in front of the appliance must be kept a minimum of 48” (121.9cm) from the front of the appliance.
All wiring should be done by a qualifi ed electrician and shall be in compliance with local codes and with
the National Electric Code ANSI/NFPA NO. 70-Current (in the United States), or with the current CSA
C22.1 Canadian Electric Code (in Canada).
This appliance and its components are designed to be installed and operated as a system. Any alteration
to or substitution for items in this system, unless allowed by these installation instructions, will void the
OMNI listing and may void the product warranty. It may also create a hazardous installation. Read through
these instructions thoroughly before starting your installation and follow them carefully throughout your
project.
2.1 general instructions
1. Combustion air is brought into the appliance
through the slots and around the glass door
or through the screen.
2. Outside air is controlled with a damper to
supplement indoor air. The damper can only
be adjusted to be fully closed or fully open.
3. Inside the fi rebox, combustion takes place
and exhausts out the chimney.
4. The appliance includes a fl ue damper at the
base of the chimney which shall be closed
when the appliance is not in use to prevent
cold air entering the home. See "fi rebrick
installation and damper operation" section.
2
3
3
1
4
OPEN
CLOSED
OPEN
The location of windows and doors, as well as the traffi c fl ow in the room where the appliance is to be located should
be considered. If possible, choose a location where the chimney will pass through the house without cutting a fl oor or
roof joist.
It is recommended to test the listed
components below before installation:
• Doors
• Balance weights
Louvre for air intake
• Flue damper
All components should be in good operating
condition before the appliance is installed.
note:
W415-1676 / E / 05.17.21
EN
8
general information
Shipped with appliance:
Installation manual
Ember strip
Flue damper tool
Do not use makeshift compromises during installation.
Do not block or restrict air, grille or louvre openings! Do
not add a hood.
Burning your appliance with the door open or ajar
creates a fi re hazard that may result in a house and/or
chimney fi re.
All venting connections must be in compliance with the chimney manufacturers installation instructions.
Clearances referred to throughout this manual are the minimum requirements.
Your appliance must be installed in accordance with all national and local building code standards and
the standard of Chimney and Appliances, Vents and Solid Fuel Burning Appliances NFPA #211. Consult
the authority having jurisdiction (such as municipal building department, fi re department, fi re prevention
bureau, etc.) to determine the need to obtain a permit. If you are in doubt about the proper installation for
your situation, contact your dealer or local building or fi re offi cial. The manufacturer does not guarantee
that this appliance and its options will completely heat your entire home.
Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
It is recommended that in all cases, the appliance be secured to the fl oor. Use the pallet packing brackets
to accomplish this.
THE NZ8000 HAS BEEN EPA QUALIFIED.
Depending on the loading method and size of log,
maximum length of 32" (81.3cm).
Large glass door for maximum visibility.
Fully refractory lined fi rebox.
Closable outside air damper.
Closable fl ue damper.
Shipping weight 1150lbs (521kg).
Flue outlet diameter 12" (30.5cm).
Max fuel load 60lbs (27kg).
Max fuel height, halfway or top of the fi rst fi re-
brick.
Safety tested to: ULC S610 and UL 127.
Emissions tested to: ASTM E2515 and ASTM
E2558 for U.S. EPA Low Mass Wood-burning
Fireplace voluntary program phase 2 emissions
level (NZ8000 only).
2.2 features
2.3 this appliance
2.4 packing list
!
WARNING
Do not let the appliance become hot enough for any part to glow red.
This appliance is a decorative product and not intended as a primary source of heat.
Approximate heating capacity up to 1,000 square feet (92 square meters).
EN
W415-1676 / E / 05.17.21
9
general information
2.5 rating plate information
Rating plate is located behind the faceplate and door guide system on the right.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
RATING
PLATE
LOCATION
Jan./Jan.
Feb./Fév.
Mar./Mars.
CERTIFIED TO / CERTIFIÉ SELON: ULC-S610, UL-127
9700539 (WSL)
4001657 (NGZ)
4001658 (NAC)
4001659 (WUSA)
LISTED FACTORY BUILT FIREPLACE.
PHASE 2 EMISSION LEVEL QUALIFIED.
LOW MASS WOOD BURNING FIREPLACE. /
NZ7000
INSTALL AND USE ONLY IN ACCORDANCE WITH WOLF STEEL LTD. INSTALLATION INSTRUCTIONS
AND OWNER'S MANUAL. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS
AND INSTALLATION INSPECTION IN YOUR AREA. DO NOT CONNECT THIS UNIT TO A CHIMNEY
SERVING ANOTHER APPLIANCE.
POUR INSTALLATION ET UTILISATION CONFORMÉMENT AUX MANUEL WOLF STEEL LTD.
RENSEIGNEZ-VOUS AUPRÈS DES AUTORITÉS LOCALES DU BÂTIMENT OU DU SERVICE DES
INCENDIES AU SUJET DES RESTRICTIONS ET DES INSPECTIONS D'INSTALLATION DANS VOTRE
RÉGION. NE PAS RACCORDER À LA CHEMINÉE D'UN AUTRE APPAREIL.
24 NAPOLEON ROAD. BARRIE, ONTARIO L4M 0G8 CANADA
COMPONENTS REQUIRED FOR INSTALLATION:
CHIMNEY REQUIREMENTS (see installation manual):
SHIPPED WITH THE FIREPLACE:
INSTALLATION MANUAL
EMBER STRIP
Chimney must be certified to one of the following standards:
ULC-S629, ULC-S604, ULC-S610 for Canada or UL-103HT, UL-103 for the United States.
Air cooled chimney: Use DuraVent DuraChimney II.
MINIMUM CHIMNEY HEIGHT
(FROM TOP OF APPLIANCE)
12 ft (3.66m) MAXIMUM # OF ELBOWS 4
W385-2168 / C
COMPOSANTS REQUIS POUR L'INSTALLATION:
EXIGENCES POUR LA CHEMINÉE (voir le manuel d'instructions)
La cheminée doit être certifiée selon l'une des normes suivantes :
ULC-S629, ULC-S604, ULC-S610 pour le Canada ou selon les normes UL-103HT, UL-103 pour les
États-Unis.
Cheminée refroidie à l'air: Utilisez DuraVent DuraChimney II.
LIVRÉ AVEC LE FOYER:
MANUEL D'INSTRUCTIONS
PARE-BRAISES
HAUTEUR MINIMALE DE LA CHEMINÉE
(DE HAUT DE L’APPAREIL)
12 pi (3,66m) # MAXIMAL DE COUDES: 4
NZ8000*
PAS LIVRÉ AVEC LE FOYER:
BRIQUE RÉFRACTAIRE
MODEL/ N° DE MODÈLE
MODEL/ N° DE MODÈLE
FOYER PRÉFABRIQUÉ HOMOLOGUÉ.
PHASE 2 NIVEAU QUALIFIÉ D’ÉMISSION.
FOYERS AU BOIS À FAIBLE MASSE.
MAXIMUM CHIMNEY HEIGHT 40 ft (12.1 m) FLUE COLLAR 12"ø
MAXIMUM OFFSET ANGLE 30º US - 45º CANADA MIN. CHIMNEY DIAMETER 10"ø
HAUTEUR MAXIMALE DE LA CHEMINÉE 40 pi (12,1 m) BUSE D'ÉVACUATION: 12"ø
ANGLE DE DÉVIATION MAXIMAL 30º US - 45º CANADA
MIN. CHEMINEE DIAMÈTRE: 10"ø
NZ7000 / NZ8000
NOT SHIPPED WITH THE FIREPLACE:
REFRACTORY BRICKS
Use Solid wood, processed solid fuel fire logs (or other specified type) fuel only. / Utilisez du bois massif,
transformés solides bûches de combustible (ou un autre type spécifié) combustible seulement.
Do not use a fireplace insert or other products not specified for use with this product.
N’utiliser pas un insert de cheminée ou d'autres produits non spécifiées pour l'utilisation avec ce produit.
*This model meets the U.S. EPA Wood-burning Fireplace Program Phase 2 emission level. To minimize smoke, always
operate your fireplace in accordance with the manufacturer’s instructions found in the owner’s manual. Additional information
about EPA’s Program is available at www.epa.gov/burnwise/index.html / Ce modèle répond à la Cheminée programme de
phase de niveau 2 des émissions États-Unis EPA à bois. Pour minimiser la fumée, toujours fonctionner votre foyer
conformément aux instructions du fabricant figurant dans le manuel du propriétaire. Des renseignements supplémentaires sur
le programme de l'EPA est disponible à www.epa.gov/burnwise/index.html
WARNING :
· For use with screen
or glass door fully
closed. Replace
ceramic glass only
with ceramic glass
obtained from the
dealer and certified
for use with this
appliance.
· Not for use in a
Mobile Home.
AVERTISSEMENT:
· Pour une utilisation
avec l’écran ou la porte
complètement fermé.
Remplacer verre
céramique seulement
uniquement avec verre
céramique obtenue
auprès du concession-
naire et certifiés pour
une utilisation avec cet
appareil.
· Ne peut pas être
installé dans une maison
mobile.
WARNING:THIS APPLIANCE HAS NOT BEEN TESTED
WITH AN UNVENTED GAS LOG SET. TO REDUCE
RISK OF FIRE OR INJURY, DO NOT INSTALL AN
UNVENTED GAS LOG SET INTO APPLIANCE. /
AVERTISSEMENT: CET APPAREIL N'A PAS ÉTÉ TESTÉ
AVEC DES BÛCHES À GAZ. POUR RÉDUIRE LES
RISQUES D'INCENDIE OU DE BLESSURES, NE PAS
INSTALLER UN BÛCHES À GAZ DANS L’APPAREIL.
PREVENT CREOSOTE FIRE: INSPECT CHIMNEY AND CHIMNEY
CONNECTOR, IF APPLICABLE, TWICE MONTHLY AND CLEAN IF
NECESSARY. DO NOT OVERFIRE: IF EXTERIOR OF UNIT GLOWS RED, YOU
ARE OVERFIRING. KEEP FURNISHINGS AND OTHER COMBUSTIBLE
MATERIALS A CONSIDERABLE DISTANCE AWAY FROM APPLIANCE. TYPE
OF FUEL: SOLID WOOD ONLY. PRÉVENIR LES FEUX DE CRÉOSOTE:
INSPECTEZ LA CHEMINÉE OU LE RACCORD DE CHEMINÉE, SI
APPLICABLE, DEUX FOIS PAR MOIS ET NETTOYEZ SI NÉCESSAIRE. NE
SURCHAUFFEZ PAS: SI L'EXTÉRIEUR DE L'UNITÉ DEVIENT ROUGE, VOUS
SURCHAUFFEZ. GARDEZ LES MEUBLES ET AUTRES MATÉRIELS
COMBUSTIBLES À UNE DISTANCE CONSIDÉRABLE DE L'APPAREIL DE
CHAUFFAGE. TYPE DE COMBUSTIBLE: SOLIDE BOIS SEULEMENT.
IMPORTANT: BEFORE COMMENCING INSTALLATION, REFER TO THE
LABEL LOCATED BEHIND THE FACEPLATE AND TO THE
MANUFACTURER'S INSTALLATION INSTRUCTIONS PACKAGED
TOGETHER WITH THIS UNIT. THE INSTALLATION MUST BE APPROVED BY
THE AUTHORITY HAVING JURISDICTION. AVANT DE COMMENCER
L'INSTALLATION, RÉFEREZ-VOUS À L'ÉTIQUETTE QUI SE TROUVE
DERRIÈRE LA FAÇADE AINSI QU'AUX INSTRUCTIONS D'INSTALLATION
DU MANUFACTURIER FOURNIES AVEC L'APPAREIL. L'INSTALLATION
DOIT ÊTRE APPROUVÉE PAR L'AUTORITÉ COMPÉTENTE.
QUALIFIED EPA PHASE 2 MODEL UNTIL JANUARY 2023/
QUALIFIÉ EPA PHASE 2 MODÈLE JUSQU'À JANVIER 2023
Apr/Avr. Jul/Juill. Oct/Oct.
May/Mai Aug/Août. Nov/Nov.
Jun/Juin Sep/Sept. Dec/Déc.
2020
NZ8000 AVERAGE
EMISSION / ÉMISSION
MOYENNE 4.87 g/kg
2021
2022
2023
MODEL CERTIFICATION DATE / DATE DE
CERTIFICATION 08/03/16
CERTIFIED TO ASTM E2515, ASTM E2558/
CERTIFIÉ AUX ASTM E2515, ASTM E2558
LISTED FACTORY BUILT FIREPLACE /
FOYER PRÉFABRIQUÉ HOMOLOGUÉ
*FOR MODEL NZ8000 ONLY /
*POUR LA MODÈLE NZ8000 SEULEMENT
MANUFACTURE DATE / DATE DE FABRICATION
SAMPLE
E
E
DE
DE
ANSNS
VOTRVOT
LE
COMPONENTS REQUIRED FORNTS REQUIRED FO
YY
REQUIREMENTS REQUIREMENT
YY
IREPLACE:REPLAC
NUALUAL
Chimney must be certified tChimney must be certified
LC-S629, ULC-S604, ULC-S610 for CC-S629, ULC-S604, ULC-S610 for C
Air cooled chimney: ir cooled c
NIMUM CHIMNEY HEIGHTNIMUM CHIMNEY HEIGHT
(FROM TOP OF APPLIANCE)
FROM TOP OF APPLIANCE)
COMPCOM
EXIGE
EXIG
É
AA
VEC LE FOYER:VEC LE FOYER:
AAA
E
L
D'INSTRUCTIONSNSTRUCTIONS
RAISESAISES
S
AM
E
M
AXIM
U
M
C
HIMN
E
MAXIMUM CHIMNE
YY
HEIGH HEIG
YY
TT
M
AXIM
U
M
O
FF
SE
MAXIMUM OFFSE
TT
AN
G
L
EANGLE
ez du bois massif,z du bois massif,
tible seulement.le seulement.
M
ce insert or other products not specifieinsert or other products not specifie
heminée ou d'autres produits non spécou d'autres produits non
creen re
or fully r fully
Replace ce
ic glass only c glass only
h ceramic glass ceramic glass
obtained from the btained from the
dealer and certified ealer and certifie
fo
r
use
with thi
s
use with th
appli
ance.
pliance.
·
N
o
t f
o
r
use
in
a
· Not for use in a
Mobile Home.Mobile Home.
M
AVERTISSEMENT:RTISSEME
·
P
ou
r
u
n
e
u
tili
sa
ti
o
n
ne utilisation
avec l’
é
cran ou la porte
ou la porte
complètement fermé.t fermé.
Remplacer verreer verre
céramique seulemcéramique seule
uniquement avuniquement av
céramiquecéramique
auprès durès d
naire e
une
É TESTÉ
E LES
ES, NE PAS S, N
L’APPAREIL.’APPAREIL
The rating plate must remain with the
appliance at all times. It must not be
removed.
note:
W415-1676 / E / 05.17.21
EN
10
installation planning
3.0 installation planning
3.1 location and clearances
IMPORTANT
This appliance, fully dressed, weighs 1400lbs
(635kg). Ensure there is adequate fl oor support
for the appliance, chimney and facing material.
Some material could weigh hundreds of pounds.
We recommend that the appliance be
secured to the fl oor in all cases.
Using the door opening as a datum, level
the appliance by shimming underneath the
appliance. Bend the four securing tabs (located
on the front and back corners), and secure the
appliance to the fl oor.
Securing Tabs
x4
!
WARNING
Wear gloves, protective footwear and safety glasses for protection.
Carefully follow the instructions for assembly of the pipe and other parts needed to install the appliance.
Failure to do so may result in a fi re, especially if combustibles are too close to the appliance or chimney and air
spacers are blocked, preventing the free movement of cooling air.
Do not draw outside air from garage spaces. Exhaust products of gasoline engines are hazardous. Do not
install outside air ducts such that the air may be drawn from attic spaces, basements or above the roofi ng
where other heating appliances or fans and chimneys exhaust or utilize air. These precautions will reduce the
possibility of appliance smoking or air fl ow reversal. The outside air inlet must remain clear of leaves, debris, ice
and/or snow. It must be unrestricted while appliance is in use to prevent room air starvation which can cause
smoke spillage and an inability to maintain a fi re. Smoke spillage can also set off smoke alarms.
Negative pressure within your home may inadvertently affect your appliance.
To prevent contact with sagging or loose insulation, the appliance must not be installed against vapour barriers
or exposed insulation. Localized overheating could occur and a fi re could result.
Do not use makeshift compromises during installation. Do not block or restrict air, grille or louvre openings. Do
not add a hood.
To prevent personal injury, keep hand tools in good condition, sharpen cutting edges and make sure tool
handles are secure.
Always maintain the minimum air space required in the enclosure to prevent fi res.
Check with local building offi cials for any permits required for installation of this appliance and notify your
insurance company prior to proceeding.
!
WARNING
Do not install into any area having a height less than 8 feet (2.4m) (ceiling of enclosure to appliance
bottom, excluding hearth height).
EN
W415-1676 / E / 05.17.21
11
installation planning
3.1.1 ventilation openings
It is recommended to provide air circulation within the enclosure by installing ventilation grilles (minimum openings
of 40 sq. inches (0.03 sq. meters) at both fl oor and ceiling levels of the enclosure). These grilles must not restrict
the fl ow of heat by more than 25%. Do not install into any area having a height less than 8 ft (2.4m) (ceiling of
enclosure to appliance bottom, excluding hearth height).
DIP
LOOP
OR
Insulating the intake liner is recommended in colder climates to prevent condensation from occurring.
It is recommended that a dip or loop is put into the duct creating a cold air trap in order to prevent cold air from
owing into the room when the appliance is not being operated (see illustration below).
The NZ7000 and NZ8000 take outside air directly into the appliance through the opening on the left side.
The fresh air inlet duct and hood must be installed lower than the fi rebox. Secure and seal the intake liner to the
collar using 3 sheet metal screws, and high temperature sealant.
The duct inlet must be located so they cannot be
blocked (i.e. snowdrifts). 12" (30.5cm) above grade
is recommended. Make a 4 ½" (114mm) inch
hole to suit in an outside wall of the house. From
outside, place the fresh air hood into the hole,
open side down. Seal with caulking and secure.
3.2 outside combustion air
It is recommended to install outside air to the appliance as this will help to prevent any smoke entering the living
space in homes that experience negative pressures. Check with local authorities having jurisdiction in your area,
as installing outside air to the appliance may be mandatory.
W415-1676 / E / 05.17.21
EN
12
installation planning
3.2.1 outside combustion air operation
The outside combustion air control is located on the left hand side of the appliance directly behind the glass door
guide rail. (FIG. 1)
Before lighting the appliance, ensure the outside combustion air control is open by pulling the lever towards the
front of the appliance.
Before closing the outside combustion air control, allow the appliance to cool completely. To close, push lever in
towards the appliance.
OPEN
CLOSE
OPEN
CLOSE
FIG. 1
EN
W415-1676 / E / 05.17.21
13
installation planning
An acceptable 70" (177.8cm) x 20" (50.8cm) non-combustible (ie: brick, stone or ceramic tile) hearth extension
must be installed. Hearth must extend 20" (50.8cm) in front of the faceplate. Hearth must extend a minimum of
12" (30.5cm) to both sides of the appliance door opening. See local building codes for more detailed dimensions.
The hearth must extend a minimum 20" (50.8cm) in front of the appliance although if raised a minimum of 6 1/2"
(165mm) the 20" (50.8cm) may be reduced to a minimum of 18" (45.7cm).
The hearth must be a minimum of 1" (25mm) thick cement board (or equivalent)
plus ¼" (6.4mm) ceramic tile.
Ensure that the gap between the appliance and a non-combustible hearth
extension is sealed with sand/cement grout or covered with
an ember strip (or both) to prevent sparks and embers from falling
into this area.
Raised hearths must be constructed of non-combustible materials such as
cement blocks or bricks.
While the appliance can be installed directly on the fl oor (using the ember
strip), a non-combustible hearth extension is required in front of the
appliance, that must not be built higher than the bottom of the appliance
faceplate. It may therefore be advisable to build the appliance on a raised
platform.
A raised hearth together with the appliance built on a raised platform is
recommended for easier wood loading and fi re viewing.
EMBER STRIP
(See “HEARTH
EXAMPLES” Section)
3.3 fl oor protection / ember strip and hearth extensions
!
WARNING
Hearth extensions are to be installed only as described to prevent high temperatures from occurring on
concealed combustible materials. Hearth ember strips prevent burning or hot particles from inadvertently
falling directly on combustible surfaces in the event the building should settle and disturb the original
construction.
W415-1676 / E / 05.17.21
EN
14
installation planning
3.3.1 hearth extension
20" (50.8cm)
6
1
/2"
(165mm)
70 3/8"
(178.7cm)
70 3/8"
(178.7cm)
20" (50.8cm)
12"
(30.5cm)
46 3/8"
(117.7 cm)
An acceptable 70" (177.8cm) x 20" (50.8cm) non-combustible (ie:
brick, stone or ceramic tile) hearth extension must be installed.
Hearth must extend 20" (50.8cm) in front of the faceplate. Hearth
must extend a minimum of 12" (30.5cm) to both sides of the
appliance [70" (177.8cm)]. See local building codes for more detailed
dimensions.
Hearth must be a minimum of 1" (25mm) thick cement board (or
equivalent) plus ¼" (6.4mm) ceramic tile.
Ensure that the gap between the appliance and a combustible hearth
extension is sealed with sand/cement grout or covered with a metal
strip (or both) to prevent sparks and embers from falling into this area.
HEARTH EXTENSION
Elevated hearths must be constructed of noncombustible materials
such as cement blocks or bricks.
While the appliance can be installed directly on the fl oor (using the
ember strip), a non-combustible hearth extension is required in front
of the appliance, that must not be built higher than the bottom of the
appliance faceplate. It may therefore be advisable to build the appliance on a raised platform.
Hearths raised minimum 6 ½" (165mm) must extend a minimum of 18" (45.7cm).
EMBER STRIP
SEE HEARTH
EXAMPLES
A raised hearth together with the appliance built on a raised platform is recommended for easier wood loading
and fi re viewing.
EMBER STRIP
(Provided)
EN
W415-1676 / E / 05.17.21
15
installation planning
NON-COMBUSTIBLE MATERIALS
SUCH AS CEMENT
BLOCKS OR BRICKS
COMBUSTIBLE FRAMING
PLYWOOD
INCREASE
HEADER HEIGHT
THIS DIMENSION
See “Framing” section
RAISED
APPLIANCE
COMBUSTIBLE FRAMING
NON-COMBUSTIBLE
MATERIALS SUCH
AS CEMENT BLOCKS
OR BRICKS
PLYWOOD
INCREASE
HEADER HEIGHT
THIS DIMENSION
See “Framing” section
RAISED
HEARTH
RAISED
APPLIANCE
COMBUSTIBLE FLOOR
EMBER STRIP
EMBER STRIP
EMBER STRIP
EMBER STRIP
COMBUSTIBLE FLOOR
MIN. 1/4” (6.4mm)
TILE OR MARBLE
20” MIN.
(50.8cm)
MIN. 1” (25mm) CEMENT BOARD
6
1
/
2
(165mm)
20” MIN.
(50.8cm)
MIN. 1/4” (6.4mm)
TILE OR MARBLE
MIN. 1” (25mm)
CEMENT BOARD
MIN. 1/4” (6.4mm)
MARBLE OR STONE
20” MIN.
(50.8cm)
20” MIN.
(50.8cm)
FACEPLATE
FACEPLATE
FACEPLATE
FACEPLATE
WARNING:
Ensure raised
platform is
designed to
support load of
fully loaded
appliance.
WARNING:
Ensure raised
platform is
designed to
support load of
fully loaded
appliance.
3.3.2 hearth examples
FLUSH HEARTH
RAISED HEARTH
RAISED APPLIANCE
RAISED HEARTH AND APPLIANCE
6”
(152mm)
W415-1676 / E / 05.17.21
EN
16
installation planning
3.3.3 fl ue damper operation
To close the damper, pull the damper control rod down and
push it to the right.
To open the damper, push the damper control rod to the left
side and release.
OPEN
CLOSED
OPEN
CLOSED
OPEN
CLOSED
The damper must be in the “open” position when burning.
note:
If the damper becomes unthreaded, it will remain in the “open” position.
note:
If the damper does not operate properly, do not proceed with chimney installation. The damper operation
should be thoroughly checked before the chimney is installed.
note:
EN
W415-1676 / E / 05.17.21
17
installation
4.0 installation
4.1 chimney
This appliance was tested to CAN/ULC S610 and UL 127 Factory Built Fireplace Standards. This appliance has
met the test criteria for Zero Clearance Installation to Combustible Surfaces and Certifi ed to burn fi rewood only.
Any chimney 10” (254mm) or 12” (30.5cm) diameter listed to CAN/ULC S610 for Canada or UL127 for the United
States or to the following standards; CAN/ULC-S604 and CAN/ULC-S629 for Canada or UL-103 or UL-103HT for
the United States may be installed.
Installation of all types of factory-built chimney systems is to be in accordance with the chimney manufacturers
installation instructions. An appropriate chimney manufacturers anchor base plate and anchor base plate gasket
is required in order to initiate their system. Use the high temperature gasket, supplied, to seal between the anchor
plate and the appliance top. Air cooled chimney systems are not
recommended in colder climates.
Chimney sections must be adequately secured one to the other to
ensure they do not separate. For complete installation instructions,
refer to instructions provided with the manufactured chimney system.
A chimney venting the appliance shall not vent any other appliance.
The minimum overall chimney height from the top of the appliance is
15ft (4.6m). The maximum overall chimney height from the top of the
appliance is 34ft (10.4m).
Factory-built chimney systems for use in dwellings constructed for
three or more families must be enclosed above the room in which the
appliance is located. This enclosure must have a fi re resistance rating equal to or greater than that of the fl oor or
roof assembly through which they pass.
The chimney should not be built with an offset angle in excess of 45° in Canada and 30° in USA.
Ensure that minimum clearances are maintained.
Portions of the chimney that extend through accessible spaces must always be encased to avoid personal
contact with the chimney and thereby avoid damage to the chimney.
The chimney must be supported at a maximum of 20ft (6.1m) intervals. Every 20 ft (6.1m) of chimney can weigh
up to approximately 200lbs (90.7kg). When using a 10" chimney, center anchor plate to appliance fl ue outlet.
ANCHOR PLATE
ANCHOR PLATE GASKET
APPLIANCE TOP
ANCHOR PLATE FOR A FACTORY
BUILT CHIMNEY
!
WARNING
Never install a single wall slip section or smoke pipe in a chase structure. The higher temperature of this single
wall pipe may radiate suffi cient heat to combustible chase materials to cause a fi re.
To avoid danger of fi re, all instructions must be strictly followed, including the provision of air space clearance
between chimney system and enclosure. To protect against the effects of corrosion on those parts exposed
to the weather.
Maintain a minimum 2” (51mm) air clearance to all parts of the chimney system at all times. Failure to maintain
this 2” (51mm) air clearance will cause a structure fi re.
Detailed instructions for installation of the storm collar and termination cap are supplied by the manufacturer
and are packaged with these parts.
Firestop spacers must be used whenever the chimney penetrates a ceiling/fl oor area.
The chimney must be sound and free of cracks. Clean your chimney a minimum of twice a year and as
required.
Always seal penetrations with temperature rated sealing products.
Installation of a combustible chase enclosure above the roof is permissible if done in accordance with the
chimney manufacturer’s installation instructions.
All venting connections must be in compliance with the chimney manufacturer’s installation instructions.
note:
Masonry chimney installs are not permitted.
note:
W415-1676 / E / 05.17.21
EN
18
installation
4.2 typical chimney installation
(10" or 12" Solid Packed or Air Cooled Chimney)
39.12
* The first flue offset closest to the top of the appliance must be a
minimum distance of 12” (30.5cm) from the top of the appliance.
A. Move the appliance into position. Try to center the exhaust
flue of the appliance, midpoint between two joists to prevent
having to cut them. Use a plumb bob to line up the centre.
B. Cut and frame an opening in the ceiling to provide a
minimum clearance of 2” (50.8mm) between the outside of
the chimney and any combustible material. DO NOT FILL
THIS SPACE WITH ANY TYPE OF MATERIAL! Nail headers
between the joists for extra support. Firestop spacers must
be placed on each framed opening in any floor or ceiling
that the chimney passes through.
C. Hold a plumb bob from the underside of the roof to
determine where the opening in the roof should be.
Cut and frame the roof opening maintaining proper
2” (50.8mm) clearances.
HEADERS
FIRESTOP SPACER -
UNDERSIDE OF JOIST
15 FT
(4.6m)
MINIMUM
34 FT
(10.4m)
MAXIMUM
RAIN CAP
RAIN CAP
RAIN CAP
STORM COLLAR
ROOF FLASHING
STORM COLLAR
ROOF FLASHING
STORM COLLAR
ROOF FLASHING
ATTIC INSULATION
SHIELD
ATTIC INSULATION
SHIELD
ATTIC INSULATION
SHIELD
CEILING RADIATION
SHIELD
OFFSET
SUPPORT
OFFSET
SUPPORT
FIRESTOP
FIRESTOP
12” (30.5cm)
MIN*
15 FT
(4.6m)
MINIMUM
34 FT
(10.4m)
MAXIMUM
12” (30.5cm)
MIN*
15 FT
(4.6m)
MINIMUM
34 FT
(10.4m)
MAXIMUM
STRAIGHT CHIMNEY SINGLE OFF-SET CHIMNEY DOUBLE OFF-SET CHIMNEY
2" (50.8mm)
Min.
Typical Roof Joist FramingTypical Joist Framing
2" (50.8mm)
Min.
2" (50.8mm)
Min.
2" (50.8mm)
Min.
note:
30° or 45° offsets may be installed back to back.
When installing a 10" or 12" air cooled chimney, an NZAC10KT must be installed, see "air cooled chimney
installation" section.
note:
See "offsee chimney installation" section.
EN
W415-1676 / E / 05.17.21
19
installation
4.3 adding chimney sections
Add chimney sections, according to the manufacturer’s installation instructions. If the chimney system passes
through an attic space, a rafter radiation shield or attic insulation shield is required. The chimney must extend at
least 3ft (0.9m) above its point of contact with the roof and at least 2ft (0.6m) higher than any wall, roof or building
within 10ft (3.1m). If the chimney extends more than 5ft (1.5m) above the roof, it must be secured using a roof
brace or guide wires. A raincap must be installed to avoid internal damage and corrosion.
3 FT (1m)
MIN
3 FT (1m)
MIN
10 FT (3m)
OR MORE
FLAT ROOF
WALL
RIDGE
LESS THAN
10FT (3m)
2 FT (0.6m) MIN
3 FT (1m)
MIN
2 FT (0.6m)
MIN
LESS THAN
10FT (3m)
3 FT (1m)
MIN
2 FT (0.6m)
MIN
10 FT (3m)
TO NEAREST
ROOFLINE
Floor, Ceiling Joist
LIVING SPACE
Framed
Enclosure
2” (51mm)
clearance from
chimney to
combustible wall
Chimney Lengths
Ceiling Joist
Chimney must be
totally enclosed
when passing
through living space
with a minimum 2”
(51mm) clearance
to combustibles.
ATTIC SPACE
W415-1676 / E / 05.17.21
EN
20
installation
4.4 offset chimney installation
The first flue offset closest to the top of the
appliance must be a minimum distance of
12" (30.5cm) from the top of the appliance.
Attach an elbow to the chimney section, angled
toward the offset. Secure according to chimney
manufacturer’s instructions. Chimney sections must
be adequately secured one to the other to ensure
they do not separate. To achieve the minimum
offset, attach and secure a second elbow. To
achieve longer offsets, you may install any available
length of chimney pipe between the elbows.
Supports must be used on the first vertical chimney
section after a return elbow.
Attic Insulation
Shield
Storm Collar
Elbow
Elbow Support
Straps
Elbow
Roof
Flashing
Rain Cap
Elbow Support
Band
Roof Joist
Chimney Section
Floor , Ceiling Joist
Firestop
If the offset length is more than 36” (91.4cm), an
intermediate support must be employed. To
achieve longer offsets, you may install any
available length of chimney pipe between the
elbows.The intermediate support must be used
in conjunction with an offset support.
!
WARNING
Chimney sections installed between an offset and return require structural support to reduce off-center
loading and to prevent chimney sections from separating at the chimney joists.
The chimney should not be built with an offset angle in excess of 45° in Canada and 30° in USA. Do not
combine offset chimney components to exceed these angles.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96

NAPOLEON NZ7000 Manuel utilisateur

Catégorie
Poêles
Taper
Manuel utilisateur

dans d''autres langues