Twin Eagles TEPB24-CN Le manuel du propriétaire

Catégorie
Barbecues
Taper
Le manuel du propriétaire

Ce manuel convient également à

TWIN EAGLES POWER BURNER
INSTALLATION, USE, & CARE MANUAL
MODELS:
TEPB24HG-C (SHOWN)
TEPB24-C
P/N: 19239F 01/19
A message to our customers
Congratulations on the purchase of your TWIN EAGLES Power Burner! Our products are
engineered for precision and designed for style. Each TWIN EAGLES Power Burner is
manufactured in the USA at our own state of the art facility in California.
This manual will give you easy to follow instructions for installing, operating and
maintaining your TWIN EAGLES Power Burner. We recommend reading this manual carefully
before your first use to ensure safety, proper care and operation.
At TWIN EAGLES, we want you to enjoy grilling and spending time together as much as
we do making memories that linger long after the grill cools down.
Thank you and welcome!
Dante Cantal
Owner and Founder
FOR YOUR RECORDS
Please record the product information below and refer to it when contacting TWIN EAGLES.
This information is found on the data nameplate, located on the bottom right hand side of the
body near the regulator. A second label with model number and serial number is located under
the right side of the front panel. Remove the drip tray to visually access the nameplate from the
front of the Power Burner.
Model #:__________________________________
Serial #: __________________________________
Date of Purchase: __________________________
Place of Purchase: __________________________
Type of Gas: NG LP
To the Installer:
Please read these instructions completely before installation and give this manual to the owner.
To the Owner:
Keep this manual in a safe place for future reference.
IMPORTANT SAFETY INFORMATION
WARNING! Read this manual carefully and completely before using your Power Burner to ensure proper
operation, proper installation, proper servicing and to reduce the risk of fire, burn hazard and/ or other injury.
AVERTISSEMENT! Lire ce manuel avec soin et en entier avant l’utilisation de votre barbecue afin d’en
assurer un fonctionnement, une installation et un entretien adéquats et réduire le risque d’incendie, de brûlures
et d’autres blessures.
F O R Y O U R S A F E T Y
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open flames.
3. Open lid.
4. If odor continues, keep away from the
appliance and immediately call your
gas supplier or fire department.
A V E R T I S S E M E N T
S’il y a une odeur de gaz:
1. Coupez l’admission de gaz de l’appariel.
2. Éteindre toute flamme nue.
3. Ouvrir le couvercle.
4. Si l’odeur continue, évite l’appareil et appelle tout de
suite votre fournisseur de gaz ou les pompiers.
F O R Y O U R S A F E T Y
1. Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
2. An LP cylinder not connected for use
shall not be stored in the vicinity of
this or any other appliance.
A V E R T I S S E M E N T
1. Ne pas entreposer ni utilizer de l’essence ni d’autres
vapuers ou liquids inflammables dans le voisinage
de l’appareil, ni de tout autre appareil.
2. Une bouteille de propane qui n’est pas raccordée en
vue de son untilisation, ne doit pas être entrpossée
dans le voisinage de cet appareil ou de tout autre
appareil.
THIS APPLIANCE IS FOR OUTDOOR
USE ONLY:
If stored indoors, detach and leave L.P.
cylinder outdoors.
CE APPARIEL EST POUR UTILISATION à
L’EXTÉRIEUR SEULEMENT:
Si l’appareil est entreposé à l’interieur, enlever
les bouteilles et les laisser à l’extérieur.
B E F O R E L I G H T I N G
1. Read instructions before lighting.
2. Remove cover during lighting.
3. If ignition does not occur in 5 seconds,
turn the burner control(s) off, wait 5
minutes, and repeat the lighting
procedure.
A V A N T D A L L U M E R
L A P P A R E I L
1. Lisez les instructions avant d’allumer l’appareil.
2. Enlevez le couvercle avant d’allumer l’appareil.
3. Si l’appareil ne s’allume pas en 5 secondes, fermez
le robinet du brûleur, attendez 5 minutes, et procédez
de nouveau à l’allumage.
W A R N I N G
Electrical Grounding Instructions: This
outdoor gas cooking appliance is equipped
with a three prong (grounding) plug for your
protection against shock hazard and should be
plugged directly into a properly grounded
three prong outlet. Do not cut or remove the
third prong from this plug.
A V E R T I S S E M E N T
Instruction pour la mise à la terre electrique:
Cet appareil est muni d’une fiche à trois broches (mise à la
terre) afin de vous protéger des chocs et doit être branché
directement dans une prise de courant à trois broches
adéquatement mise à la terre. Il ne faut pas couper ou
enlever la broche de mise à la terre de cette fiche.
GENERAL SAFETY REQUIREMENTS
1. The installation of this appliance must conform with local codes or, in the absence of local codes, either the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, Natural Gas and Propane Installation Code, CSA B149.1
or Propane Storage and Handling Code, B149.2
2. The utilization of an external electrical source requires that when installed, this outdoor cooking gas appliance
must be electrically grounded in accordance with the local codes or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1. Keep any electrical
supply cord, or the fuel supply hose away from any heated surfaces.
3. This outdoor cooking gas appliance shall be used only outdoors and shall not be used in a building, garage or
any other enclosed area.
4. This outdoor cooking gas appliance is not intended to be installed in or on recreational vehicles and /or boats.
5. Minimum clearance of 12 inches from the back and sides of the Power Burner to adjacent combustible
construction must be maintained. This outdoor cooking gas appliance shall not be located under
overhead-unprotected combustible construction.
6. Keep your Power Burner in an area clear and free from combustible materials, gasoline and other flammable
vapors and liquids.
7. DO NOT obstruct the flow of combustion and ventilation air to this appliance. Keep the ventilation openings
of the cylinder enclosure free and clear from debris.
8. Check all gas connections for leaks with soapy water solution and brush. Never use an open flame. (Reference
page 6 for leak test procedure).
9. Check flexible hoses for cuts and wear that may affect the safety before each use.
10. Always use caution when operating the power burner in a windy area.
11. Never use the Power Burner without the drip pan installed and push all the way to the back of the Power
Burner. Without the drip pan, hot liquid and debris could leak downward and produce a fire hazard.
12. The pressure regulator supplied with the Twin Eagles Gas Power Burner must be used. Replacement pressure
regulators must be those specified by Twin Eagles.
TABLE OF CONTENTS
GETTING STARTED……………………………………………………………………………………………………….
LOCATING THE POWER BURNER
o CLEARANCE TO COMBUSTIBLE CONSTRUCTION………………………..…………………………
o CLEARANCE TO NONCOMBUSTIBLE CONSTRUCTION……………….……………………………
GAS REQUIREMENTS
o GAS SAFETY REQUIREMENT…………………………………………..……………..............................
o LP GAS HOOKUP………….………………………………………………………..……………………...
o NATURAL GAS INSTALLATION…………………………………………………..…………………….
o LEAK TEST…………………………………………………………………………….…………………...
o BURNER FLAME / AIR SHUTTER ADJUSTMENT ……………………………………………………..
ELECTRICAL REQUIREMENTS ……..…………………………..………………………………..…………………….
CUTOUT DIMENSIONS…………..……………………………………..............................................................................
OPERATING INSTRUCTIONS
o BEFORE LIGHTING………………………………………………………………………………………..
o HOW TO LIGHT………………………………….….………………….......................................................
o MATCH LIGHTING INSTRUCTIONS ……..………...…………...............................................................
CLEANING AND MAINTENANCE
o STAINLESS STEEL…………………………………………………………………………………………
o GRATES………………………………………………………………………….…….……………………
o BURNER …………………………………………………………………….………...................................
o SPIDER AND INSECT WARNING………………………………………………………………………...
o BURNER INSTALLATION CHECK……………………………………………………………………….
o WIRING DIAGRAM………………………………………………………………………………………...
REPLACEMENT PARTS
o EXPLODED VIEW……………………………………………………….…………...…………………….
o REPLACEMENT PARTS LIST……..………………….……………….….……..………………………...
o TROUBLE SHOOTING GUIDE.....………………………………………………..……………………….
o LIMITED PRODUCT WARRANTY…………………………………………...…..……………………....
o WARRANTY REGISTRATION CARD
1
2
2
3
4
5
6
7
8
10
9
10
10
11
12
12
12
14
15
16
17
13
13
1
GETTING STARTED
1. Remove all packaging materials, labels and protective plastic film. DO NOT LEAVE UNIT UNDER THE
SUN WITH PROTECTIVE PLASTIC FILM ON FOR A LONG PERIOD OF TIME AS IT WILL BE
DIFFICULT TO REMOVE THE FILM.
2. Check to ensure that all Power Burner accessories listed below are included.
3. Fill up the Warranty Registration Card and mail it to the indicated address.
Power burner Accessories
TEPB24-BN
TEPB24-BL
TEPB24HG-BN
TEPB24HG-BL
Grate, Round, Stainless Steel
1
1
Grate, Round, Middle, Stainless Steel
1
1
Grate, Power Burner (Optional heavy duty)
1
1
Regulator, NG (NG Power burner only)
PRE-INSTALLED
Regulator, LP (LP Power burner only)
PRE-INSTALLED
Specifications
Value
Counter Opening Height
11.50”
Counter Opening Width
22.00”
Counter Opening Depth
20.50”
Btu
70,000
NG Orifice Outer Ring
#30
NG Orifice Inner Ring
#41
LP Orifice Outer Ring
#49
LP Orifice Inner Ring
#53
2
LOCATING THE POWER BURNER
This gas appliance is designed and certified for outdoor use only. Do not locate this Power Burner under
overhead combustible surfaces. Do not operate the Power Burner inside a building, garage, recreation vehicle or
any enclosed area. CAUTION should be taken when grills are used near glass, vinyl siding or other temperature
sensitive construction materials. In some cases it may be necessary to increase the clearance around the grill to
avoid damage to vinyl siding. Check with the manufacturer of the siding material for details. When choosing an
area, consider exposure to wind, proximity to traffic paths and length of gas supply line. Keep gas supply lines
as short as possible to reduce pressure drop. Keep the Power Burner away from windy area but keep the Power
Burner in a well-ventilated area. Do not obstruct the flow of combustion and ventilation air around the Power
Burner. The supporting edges of the Power Burner must be located level and flat. The counter should also be
leveled.
CLEARANCE TO COMBUSTIBLE CONSTRUCTION
A minimum clearance of 12” from the sides and 6” from the back of the Power Burner to adjacent vertical
combustible construction must be maintained.
DÉGAGEMENT DE TOUTE CONSTRUCTION COMBUSTIBLE
Il faut maintenir une distance minimum de 12 po (30.48 cm) sur les côtés et de 6 po (15.24 cm) sur l’arrière du
gril par rapport aux constructions combustibles verticales adjacentes.
CLEARANCE TO NONCOMBUSTIBLE CONSTRUCTION
A minimum clearance of 1from the back of the Power Burner above cooking surface to non-combustible
construction is required.
A minimum of 1 clearance to the sides of the Power Burner above cooking surface to non-combustible
construction is recommended. The Power Burner can be installed directly next to non-combustible construction
below the cooking surface.
DÉGAGEMENT DE TOUTE CONSTRUCTION INCOMBUSTIBLE
Une distance minimum de 1 po (2.54 cm) de l’arrière du Puissant Bruleur au-dessus de toute surface de cuisson
à la construction incombustible est prescrite. Une distance minimum de 1 po (2.54 cm) des côtés du Puissant
Bruleur au-dessus de la surface de cuisson à la construction incombustible est recommandée. Le Puissant Bruleur
peut être installé directement à proximité d’une construction incombustible en-dessous de la surface de cuisson.
3
GAS SAFETY REQUIREMENTS
Each appliance is set and tested at the factory for the type of gas supply to be used. Identify the type of
gas, either natural gas or LP gas and make sure that the marking on the data plate (rating plate) matches the gas
being supplied to the Power Burner. The data plate is located on the panel behind the control panel of the Power
Burner. Remove the drip pan to visually access the nameplate label from the front of the Power Burner. A second
label with model number and serial number is located under the right side of the control panel.
All gas connections should be made by a qualified technician and in accordance with local codes and
ordinances. The installation must conform with local codes or, in the absence of local codes, with either the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, Natural Gas and Propane Installation Code, CSA B149.1 or
Propane Storage and Handling Code, B149.2
WARNING:
CHECK TO ENSURE THAT THE GAS SUPPLY HOSE DOES NOT COME IN CONTACT WITH
ANY HOT SURFACE OF THE POWER BURNER.
NEVER CONNECT THE POWER BURNER TO AN UNREGULATED GAS SUPPLY.
L.P. GAS SAFETY REQUIREMENT
The LP-gas supply cylinder must be constructed and marked in accordance with the Specifications for LP-gas
Cylinders of the U.S. Department of Transportation (D.O.T.) or the National Standards of Canada CAN/CSA-
B339, Cylinders, Spheres and Tubes for the Transportation of Dangerous Goods, and Commission, as
applicable; and
1. Provided with a listed overfilling prevention device.
2. Provided with a cylinder connection device compatible with the connection for outdoor cooking
appliances.
It must be provided with a shut-off valve terminating in gas tank valve outlet. It must include a collar to
protect the cylinder valve. The cylinder supply system must be arranged for vapor withdrawal.
Do not operate the gas grill indoors or in any enclosed area. If the gas grill is not in use, the gas must be
turned off at the supply cylinder. If the grill is to be stored indoors, disconnect the gas supply cylinder
and leave the cylinder outdoors out of reach of children and must not be stored in a building, garage or
any other enclosed area.
4
LP GAS HOOK-UP
A typical LP gas installation is shown on the right. Make sure that the factory-supplied regulator is used and
installed with the arrow mark on the regulator pointing towards the Power Burner. Do not use any replacement
regulator other than that specified by Twin Eagles. Use only pipe sealants that are approved for use with natural
and LP gases. An installer-supplied gas shutoff valve must be installed in an accessible location. (Reference:
page 6 for leak test procedure). Although LP gas cylinder may be used, it is not recommended due to the
large amount of gas consumption of the unit and will freeze up the LP gas cylinder
Note: An enclosure for LP gas cylinder must be vented on the level of the cylinder valve and at floor level. The
effectiveness of the opening(s) for purposes of ventilation shall be determined with the LP gas supply cylinder in
place. This shall be accomplished by one of the following:
a. One side of the enclosure shall be fully open; or
b. For a cylinder enclosure having four sides, a top and a bottom, and intended for installation in a built-in
enclosure:
1. At least one ventilation opening shall be provided on the exposed exterior side of the enclosure located
within 5 in (1.27mm) of the top of the enclosure and unobstructed. The opening(s) shall have a total free
area of not less than 1 in²/lb (14.2 cm²/kg) of stored fuel capacity.
2. At least one ventilation opening shall be provided on the exposed, exterior side of the enclosure 1 in.
(25.4 mm) or less from the floor level and shall have a total free area of not less than ½ in²/lb (7.1
cm²/kg) of stored fuel capacity. The upper edge shall be no more than 5 in (127 mm) above the floor
level.
3. Every opening shall have a minimum dimension so as to permit the entrance of 1/8 in (3.2 mm) rod.
CAUTION: Provide adequate ventilation holes in the enclosure for safety purposes in the event of a gas leak.
! WARNING !
DO NOT STORE SPARE LP-GAS CYLINDER UNDER OR NEAR THIS APPLIANCE.
NEVER FILL THE CYLINDER BEYOND 80 PERCENT FULL.
FAILURE TO DO SO A FIRE CAUSING DEATH OR SERIOUS INJURY MAY OCCUR.
USE ONLY A 20-lbs (5 GALLON CAPACITY) GAS CYLINDER
DO NOT USE A DENTED OR RUSTED LP CYLINDER
NEVER USE A CYLINDER WITH A DAMAGED VALVE
ALWAYS CHECK FOR LEAKS AFTER CHANGING THE LP CYLINDER
THE LP REGULATOR AND HOSE SUPPLIED WITH THIS UNIT MUST BE USED
WITHOUT ALTERATION
5
NATURAL GAS HOOK-UP
The installation must conform with local codes or, in the absence of local codes, with either the National
Fuel Gas Code, ANSI Z223.1/NFPA 54, Natural Gas and Propane Installation Code, CSA B149.1 or Propane
Storage and Handling Code, B149.2.
1. This gas appliance and its individual shutoff valve must be disconnected from the gas supply piping system
during any pressure testing of that system at the test pressures in excess of 1/2 psi (3.5 kPa).
2. This appliance must be isolated from the gas supply piping system by closing its individual manual shutoff
valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2
psi (3.5 kPa).
If the gas Power Burner is factory built for natural gas, the regulator supplied is set for 4” water column.
The regulator is convertible to 10 in wc (2.49 kPa) water column for system LP application. Do not use with a
20-lb LP cylinder. Make sure that the regulator is set for natural gas. To check, remove the brass hex cap. You
will find the conversion plastic pin attached to the cap to the underside of the cap. If the disc (1/2 in. diameter)
of the pin is close to the cap, then the regulator is set for natural gas. If the disc is at the tip of the pin, away
from the brass cap, the regulator is set for system LP application. To convert to natural gas, remove the plastic
conversion pin and invert and replace it back in a manner such that the disc is close to the brass cap. For both
natural and LP, the maximum inlet pressure is 14 in wc (3.5 kPa).
Make sure that the factory-supplied regulator is used and installed with the arrow mark on the regulator
pointing towards the gas Power Burner. Do not use any replacement regulator other than that specified by Twin
Eagles. Use only pipe sealants that are approved for use with natural and LP gases. An installer-supplied gas
shutoff valve must be installed in an accessible location.
REGULATOR IS SET
TO NATURAL GAS
REGULATOR IS SET
TO LP GAS
6
LEAK TEST
CAUTION BEFORE LIGHTING
Finding and/or fixing a gas leak is NOT a “DO IT YOURSELF” procedure.
NEVER USE THE POWER BURNER WITHOUT FIRST LEAK TESTING THE GAS
CONNECTIONS
WARNING: DO NOT USE AN OPEN FLAME TO CHECK FOR LEAKS. USE OF AN OPEN
FLAME COULD RESULT IN A FIRE, EXPLOSION, AND BODILY HARM.
DO NOT SMOKE WHILE PERFORMING THE LEAK TEST!
To prevent fire or explosion hazard, DO NOT use or permit sources of ignition in the area while
performing a leak test. Perform leak test outdoors only.
Check to ensure that flexible hose do not have any cuts and wear that may affect the safety before each
use. Only the factory supplied regulator must be used. Use only replacement regulator specified by Twin
Eagles.
LEAK TEST
1. Prepare a leak testing solution of sudsy water by mixing in a spray bottle with half liquid soap and half
water.
2. Confirm that all control knobs are in the OFF position.
3. Turn the main gas valve ON.
4. Apply leak testing solution by spraying on the pipe joints, fitting, and hose.
5. A gas leak is detected if,
a. There is a faint gas smell and/or…
b. …growing bubbles appear on any of the connection points and/or hose, DO NOT attempt to
ignite Power Burner and IMMEDIATELY turn off the gas supply valve.
6. When there is a gas leak, call a qualified service technician. DO NOT use the Power Burner until the
leak is corrected.
7
BURNER FLAME / AIR SHUTTER ADJUSTMENT
Each grill burner is tested and adjusted at the factory prior to shipment; however, variations in the local gas
supply may make it necessary to adjust the burners. The flames of the U-burners should be visually checked.
Flames should be blue and stable with little to no yellow tips, no excessive noise or lifting. If any of these
conditions exist, remove the burner and check to see if any air shutter or burner ports are blocked by dirt, debris,
spider webs, etc. if it is clear, the air shutter may need to be adjusted.
ADJUSTING THE GRILL BURNER FLAME - The amount of air is controlled by a sheet metal cup at the
inlet of the burner called an air shutter. It is locked in place by a set screw which must be loosened prior to lighting
the burner for adjustment. The air shutter adjustment screws are accessible with a phillips screwdriver. Loosen
the lock screw of the air shutter. Adjust according to the following directions. Be careful as the burner may be
very hot.
If the flame is yellow, indicating insufficient air, turn the air shutter counter-clockwise to allow more air
to the burner.
If the flame is noisy and tends to lift away from the burner, indicating too much air, turn the air shutter
clockwise.
Remember to tighten the set screw prior to re-installing the burner.
ENSURE THAT THE BURNERS ARE SITTING PROPERLY ON THE ORIFICES BEFORE
LIGHTING THE BURNERS.
8
ELECTRICAL REQUIREMENTS
The appliance should only be taken apart by a qualified technician, or electrical shock may occur. It is rated at
120V, 60Hz, and 2.2A.
REMINDER:
Keep any electrical supply cord and the fuel supply hose away from any heated features.
Electrical equipment provided with the outdoor cooking appliance shall follow these guidelines:
1. To protect against electrical shock, do not immerse cord or plugs in water or other liquid;
2. Unplug from the outlet when not in use and before cleaning. Allow to cool before putting on or taking off
parts;
3. Do not operate any outdoor cooking gas appliance with a damaged cord, plug, or after the appliance
malfunctions or has been damaged in any manner. Contact the manufacturer for repair;
4. Do not let cord hang over the edge or touch hot surfaces;
5. Do not us an outdoor cooking gas appliance for purposes other than intended;
6. When connecting , first connect plug to the outdoor cooking gas appliance then plug appliance into outlet;
7. Use only Ground Fault Interrupter (GFI) protected circuit with this outdoor cooking gas appliance;
8. Never remove the grounding plug or use with an adapter of two prongs; and
9. Use only extension cords with three prong grounding plug, rated for the power of the equipment, and
approved for outdoor use with a W-A marking.
WARNING
Electrical Grounding Instructions:
This outdoor gas cooking appliance is equipped with a three prong (grounding) plug for
your protection against shock hazard and should be plugged directly into a properly
grounded three prong outlet. Do not cut or remove the third prong from this plug.
9
CUT-OUT DIMENSIONS
WARNING: The Power Burner must be installed in a NON-COMBUSTIBLE ENCLOSURE ONLY.
NOTE:
IT IS RECOMMENDED TO BUILD
THE ENCLOSURE FOR THE POWER
BURNER 6”-12” LOWER THAN THE
COUNTERTOP.
10
OPERATING INSTRUCTIONS
BEFORE LIGHTING THE POWER BURNER
DO NOT ATTEMPT TO LIGHT THE POWER BURNER IF YOU SMELL GAS
WARNING! IT IS CRITICAL THAT THE GAS BURNER IS PROPERLY INSTALLED WITH
THEIR ORIFICES INSIDE THE BURNERS AIR SHUTTERS. If not properly installed, gas may
leak outside of the burner that could lead to fire, potential damage to your Power Burner and bodily
injury.
Inspect the gas supply piping or hose prior to turning the gas ON. If there is evidence of cuts, wear, or
abrasion, it must be replaced prior to use. The replacement pressure regulator and hose assembly must
be the type specified by the manufacturer. Do not use the Power Burner if the odor of gas is present. The
pressure regulator and hose assembly supplied with the units must be used.
If the unit is LP, screw the regulator and hand tighten to the valve of the cylinder and leak check the hose
and regulator connections with a soap and water solution before operating the Power Burner. Reference
page 6 for leak test procedure.
Always keep your face and body as far away as possible when lighting.
Refer to spiders and insects warning and procedure under the cleaning and maintenance page of this
manual.
TO LIGHT THE POWER BURNER’S BURNER
Lighting the Power Burner
1. Open the gas supply shut-off valve.
2. Push in the knob and verify that the hot surface igniter glows. If the igniter does not glow, verify for
proper power supply. (Reference page 8 for electrical requirements).
3. Once the glowing is verified for 5 seconds simultaneously push-in and turn the
knob counter-clock-wise to the biggest flame marking on the bezel. Hold the
knob pushed in for 5 seconds. Once you see or hear a flame you can release the
knob.
CAUTION: If ignition does not take place within 5 seconds, turn knob to the OFF
position, wait for five minutes and repeat step 3.
Match/BBQ Lighter Lighting Instructions:
If there is no electrical power supply available or if hot surface igniter will not light the burner, the burner can
be lit manually using a lighted long match, taper or BBQ lighter.
1. Push and turn the knob counter-clock-wise to the biggest flame marking on the bezel. Hold the knob
pushed in for 5 seconds.
2. Insert a lit match or BBQ lighter thru the grates and near the top of the burner. Once you see or hear a
flame you can release the knob.
Important: If burner fails to light within 5 seconds, turn off gas and wait 5 minutes before repeating the
process.
Warning: If you smell gas, shutoff the gas supply and immediately check for leaks using the soapy water
technique outlined in the Leak Test section (Pg 6).
11
CLEANING AND MAINTENANCE
General Overview
Proper care, maintenance, and cleaning will help ensure a long life of your Power Burner. Periodic cleaning will
help avoid accumulations of flammable grease, fats, and other debris.
Caution: Always allow the Power Burner to cool before cleaning.
Stainless Steel & General Product Care
To keep your Power Burner free of surface corrosion and in good working order, it is important to take
additional precautions under certain conditions.
If your Power Burner is located in corrosive conditions, such as:
A coastal environment where corrosive salty air is present
Near a swimming pool, hot tub or water feature with exposure to corrosive pool chemicals and/or
chlorinated water
Areas where muriatic acid (hydrochloric acid) or other corrosive cleaning solutions are used to clean
concrete and masonry
Areas where corrosive masonry dust and debris are created by cutting stone or mixing cements
These conditions can create a highly corrosive environment that will cause the corrosions resistant type 304
stainless steel to develop surface oxidation, corrosions or rust.
TWIN EAGLES products have been tested in saline solutions, highly chlorinated solutions and have been tested
against exposure to highly acidic foods. The test results proved the type 304 stainless steel can withstand
exposure over prolonged periods of time. However, the conditions outlined above, along with neglect, can lead
to surface corrosion or rust.
ATTENTION:
Do not allow food particles or grease to be left on the surfaces of the Power Burner. These can attract
rodents, which are unsanitary and are likely to cause physical damage by chewing on the wiring, which
can cause permanent damage to the electrical components.
Specks of grease can gather on the surface of the stainless steel and get baked-on. These can be removed
by using a mild abrasive pad with a stainless steel cleaner. Use the mildest cleaner and always scrub in
the direction of the grain. Do not use steel wool to clean any surfaces on the Power Burner.
In the event that surface corrosion has developed on the stainless steel, it is typically not the stainless
steel that is corroding but corrosive particles that have been deposited on the surface.
WARNING:
It is recommended that your TWIN EAGLES products be kept dry and covered when not in use. This is even
more important when long-term storage is intended.
If you are located along the coast or in the desert, wind driven sand is extremely abrasive and can pit and
scratch the stainless steel. Keep your TWIN EAGLES products covered when not in use.
KEEP IN MIND:
TWIN EAGLES products are made of all welded stainless steel. It is non-rusting and non-magnetic. Never
clean the stainless steel when it is hot. After the initial use, certain areas of the Power Burner may discolor.
This is a normal discoloration caused by the stainless steel being exposed to high heat.
12
GRATES
Round Grates
The easiest way to clean the grates is to scrub them with a barbeque
brush immediately after cooking is completed and the flame is turned
off.
Wear a barbeque mitt to protect your hands from the heat and steam.
Dip a brass bristle barbeque brush in tap water and scrub the hot
grates. Dip the brush frequently in tap water. Steam, created as water
comes in contact with the hot Power Burner, helps loosen food
particles stuck in the Power Burner. These food particles will either
get burned or fall into the cleaning pan. Cleaning of the Power Burner
would be longer and more difficult if the Power Burner grates are
allowed to cool before cleaning.
Heavy Duty Grate
Use warm water and soap to clean the heavy duty grates. Use non-abrasive
sponge to clean off the food particles.
BURNERS
Burners are made of heavy gauge brass and can be cleaned using a bristle
brush, warm water and soap. Check every port hole for clogs. Use a wire pin
to clean out clogged ports. Make sure the burner is dry before installing it
back to the Power Burner.
DRIP PAN
The drip pan collects grease, liquid and fallen food particles. Allow the pan
and its contents to cool before cleaning. Slide the pan out and wipe it clean.
Make sure the drip pan is fully inserted back into the Power Burner. It is
highly recommended to clean the pan after every use to avoid any possibility
of a grease fire. DO NOT use the Power Burner without the drip pan pushed
all the way to the back of the Power Burner unit.
SPIDER AND INSECT WARNING
Spiders and other insects can nest in the burners and orifices of this and any other outdoor products, which
causes the gas to flow from the front of the burner. This can create a dangerous condition that can cause a fire
behind the valve panel, damaging the Power Burner and making it unsafe to operate.
Inspect the burners once a year, or if the Power Burner has not been used for more than a month or if any of the
following conditions occur:
1. The smell of gas in conjunction with the burner flames appearing yellow.
2. The burner does not reach temperature.
3. The burner heats unevenly.
4. The burner makes popping noise.
13
BURNER INSTALLATION CHECK
ELECTRICAL DIAGRAM
CORRECT INSTALLATION
THE ORIFICE IS COMPLETELY
INSERTED INTO THE VENTURI
INCORRECT INSTALLATION
THE ORIFICE IS OUT OF POSITION AND IS NOT INSERTED INTO THE VENTURI
14
EXPLODED VIEW
15
REPLACEMENT PARTS LIST
Item
No.
Part Number
Description
TEPB24HG
-CN
TEPB24HG
-CL
TEPB24-
CN
TEPB24-
CL
1
S22321
Power Burner Cover
1
1
1
1
2
S22330Y
Heavy Duty Grate
1
1
-
-
3
S13362Y
Brass Burner
1
1
1
1
4
S14289
Brass Bushing
1
1
1
1
5
S16322Y
Hot Surface Igniter
1
1
1
1
6
S22309
Top Trim
1
1
1
1
7
S22341Y
Flame Diverter
1
1
1
1
8
S13117
Cover Handle
1
1
1
1
9
S22315Y
Drip Pan Assembly
1
1
1
1
10
S13892
Round Middle Grate
-
-
1
1
11
S13891
Round Grate
-
-
1
1
12
S14420
Roller Bearing
4
4
4
4
13
S15110-30
Center Orifice #30, NG
1
-
1
-
14
S15110-41
Outside Orifice #41, NG
1
-
1
-
15
S12408
Regulator, NG
1
-
1
-
16
S16323
Regulator, NG (converted to LP)
-
1
-
1
17
S12762
Manifold Pipe
1
1
1
1
18
S12407
SS Flexible Tubing, .375 x 7
2
2
2
2
19
S12601
Elbow, .375CC x .125FIP
2
2
2
2
20
S15149
Gas Valve With Microswitch
2
2
2
2
21
S12688Y
IR Burner Elbow Assembly
2
2
2
2
22
S16404
Power Supply, LPV-60-12
1
1
1
1
23
S26366Y
Power Supply Bracket
1
1
1
1
24
S16111
Electrical Cord
1
1
1
1
25
S16112
Strain Relief
1
1
1
1
26
S13204
Logo, Twin Eagles
1
1
1
1
27
S14160
Tinnerman Clips
2
2
2
2
28
S26331-24WY
Front Panel Welded Assy.
1
1
1
1
29
S16196
12V Switch, Illuminated, 19mm,
Blue
1
1
1
1
30
S13270
Light Bezel
2
2
2
2
31
S13224
Bezel Glass
2
2
2
2
32
S13226
Rubber Retention Ring
2
2
2
2
33
S13235
Knob Assembly
2
2
2
2
Non-Shown Parts
S15110-49
Center Orifice, #49, LP
-
1
-
1
S15110-53
Outside Orifice, #53, LP
-
1
-
1
S16403
Power Burner Wire Harness
1
1
1
1
S16300
Wire Harness, Igniter to Switch
1
1
1
1
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Twin Eagles TEPB24-CN Le manuel du propriétaire

Catégorie
Barbecues
Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues