DeWalt DCT416S1 Manuel utilisateur

Catégorie
Thermomètres corporels numériques
Taper
Manuel utilisateur
DCT416
12V Max* Cordless Imaging Thermometer
Thermomètre imageur sans fil 12 V max*
Dispositivo termográfico inalámbrico de 12 V Máx*
INSTRUCTION MANUAL
GUIDE D'UTILISATION
MANUAL DE INSTRUCCIONES
INSTRUCTIVO DE OPERACIÓN, CENTROS DE SERVICIO Y PÓLIZA DE
GARANTÍA. ADVERTENCIA: LÉASE ESTE INSTRUCTIVO ANTES DE
USAR EL PRODUCTO.
If you have questions or comments, contact us.
Pour toute question ou tout commentaire, nous contacter.
Si tiene dudas o comentarios, contáctenos.
1-800-4-DEWALT • www.dewalt.com
1
English
SAVE ALL WARNINGS AND INSTRUCTIONS
FOR FUTURE REFERENCE
Work Area Safety
a) Keep work area clean and well lit. Cluttered or dark areas
invite accidents.
b) Keep children and bystanders away while operating an
imaging thermometer. Distractions can cause you to lose
control.
Personal Safety
a) Stay alert, watch what you are doing and use common
sense when operating an imaging thermometer. Do not
use an imaging thermometer while you are tired or under
the influence of drugs, alcohol or medication. A moment of
inattention while operating the imaging thermometer may result
in serious personal injury.
b) Do not overreach. Keep proper footing and balance at all
times. This enables better control of the imaging thermometer
in unexpected situations.
Use and Care
a) Store an idle imaging thermometer out of the reach of
children and do not allow persons unfamiliar with the
imaging thermometer or these instructions to operate
the imaging thermometer. The imaging thermometer may be
dangerous in the hands of untrained users.
b) Use the imaging thermometer, accessories, etc. in
accordance with these instructions, taking into account
the working conditions and the work to be performed.
Use of the imaging thermometer for operations different from
those intended could result in a hazardous situation.
Defi nitions: Safety Guidelines
The definitions below describe the level of severity for each
signal word. Please read the manual and pay attention to these
symbols.
DANGER: Indicates an imminently hazardous situation
which, if not avoided, will result in death or serious injury.
WARNING: Indicates a potentially hazardous situation
which, if not avoided, could result in death or serious injury.
CAUTION: Indicates a potentially hazardous situation which,
if not avoided, may result in minor or moderate injury.
NOTICE: Indicates a practice not related to personal injury
which, if not avoided, may result in property damage.
IF YOU HAVE ANY QUESTIONS OR COMMENTS ABOUT THIS OR
ANY D
EWALT TOOL, CALL US TOLL FREE AT: 1-800-4-DEWALT
(1-800-433-9258).
WARNING: To reduce the risk of injury, read the instruction
manual.
Important Safety Instructions
Read these instructions.
Keep these instructions.
Heed all warnings.
Follow all instructions.
Only use attachments/accessories specified by the manufacturer.
Refer all servicing to qualified service personnel. Servicing is
required when the apparatus has been damaged in any way,
the apparatus has been exposed to rain or moisture, does not
operate normally, or has been dropped.
2
English
Battery Tool Use and Care
a) Recharge only with the charger specified by DEWALT. A
charger that is suitable for one type of battery pack may create
a risk of fire when used with another battery pack.
b) When battery pack is not in use, keep it away from other
metal objects like paper clips, coins, keys, nails, screws,
or other small metal objects that can make a connection
from one terminal to another. Shorting the battery terminals
together may cause burns or a fire.
c) Under abusive conditions, liquid may be ejected from
the battery; avoid contact. If contact accidentally occurs,
flush with water. If liquid contacts eyes, additionally seek
medical help. Liquid ejected from the battery may cause
irritation or burns.
Safety Information for Imaging
Thermometers
WARNING:
Do not disassemble or modify the imaging thermometer.
Have the imaging thermometer serviced by a qualified
repair person using only identical replacement parts. This
will ensure that the safety of the power tool is maintained. If you
need assistance contact D
EWALT at 1-800-4-DEWALT (1-800-
433-9258) or go to http://www.dewalt.com on the Internet.
Do not operate the imaging thermometer in explosive
atmospheres, such as in the presence of flammable liquids,
gases, or dust. Imaging thermometers create sparks which may
ignite the dust or fumes.
The imaging thermometer should only be used with
specifically designated D
EWALT batteries. Use of any other
batteries may create a risk of fire.
Store the imaging thermometer out of reach of children and
other untrained persons. Tools are dangerous in the hands of
untrained users.
Do not remove or deface warning labels.
Do not use imaging thermometer for testing temperatures
of cooked or uncooked food.
Do not touch surfaces to confirm hot temperature readings.
Do not use for taking human or animal body temperatures.
WARNING: Burn hazard. The reading may not be accurate if the
imaging thermometer is in the presence of strong electromagnetic
fields (such as arc welders, induction heaters, ratio transmitters, etc.).
Do not use the imaging thermometer under these conditions.
WARNING: The imaging thermometer measures surface
temperature only. Objects behind the surface may have significantly
different temperatures, posing a burn or frostbite hazard.
WARNING: See emissivity information for actual temperatures.
Reflective objects result in lower than actual temperature
measurements and can pose a burn hazard.
WARNING: Do not expose imaging thermometer to excessive
heat such as sunshine, fire or the like.
CAUTION: When not in use, place imaging thermometer on
its side on a stable surface where it will not cause a tripping or
falling hazard. Some tools with large battery packs will stand upright
on the battery pack but may be easily knocked over.
NOTICE: Modifications not authorized by the manufacturer may void
user's authority to operate this device.
NOTICE: To avoid damage to the imaging thermometer, do
not leave it exposed to high temperature environments or heat
sources, for example, in a vehicle in the sun. Always operate the
imaging thermometer within the operating range noted in the
specification chart.
3
English
NOTICE: Do not point the imaging thermometer (with or without the
lens cover engaged) at the sun or other intensive energy sources that
emit laser radiation. This can damage the detector inside the imaging
thermometer and can effect the accuracy.
MICRO SD MEMORY CARD
WARNING: Choking hazard. The micro SD memory card is a
small part that could lead to a choking hazard and is not intended for
children.
NOTICE: It is recommended to use the micro SD memory card
supplied with the imaging thermometer. D
EWALT does not warrant
the use or reliability of other aftermarket cards with different brands
or capacities. It is also recommended to frequently transfer the saved
images to a computer as a backup.
Regulatory Notices
• This Class B digital apparatus complies with Canadian ICES-003.
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including
interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or
more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
Important Safety Instructions for All
Battery Packs
When ordering replacement battery packs, be sure to include catalog
number and voltage. Consult the chart at the end of this manual for
compatibility of chargers and battery packs.
The battery pack is not fully charged out of the carton. Before using
the battery pack and charger, read the safety instructions below, then
follow charging procedures outlined.
READ ALL INSTRUCTIONS
Do not charge or use battery in explosive atmospheres,
such as in the presence of flammable liquids, gases or dust.
Inserting or removing the battery from the charger may ignite the
dust or fumes.
NEVER force battery pack into charger. DO NOT modify
battery pack in any way to fit into a non-compatible charger
as battery pack may rupture causing serious personal injury.
Consult the chart at the end of this manual for compatibility of
batteries and chargers.
Charge the battery packs only in D
EWALT chargers.
DO NOT splash or immerse in water or other liquids.
Do not store or use the tool and battery pack in locations
where the temperature may reach or exceed 105 ˚F (40 ˚C)
(such as outside sheds or metal buildings in summer).
4
English
Contents of opened battery cells may cause respiratory
irritation. Provide fresh air. If symptoms persists, seek medical
attention.
WARNING: Burn hazard. Battery liquid may be flammable if
exposed to spark or flame.
The RBRC™ Seal
The RBRC™ (Rechargeable Battery Recycling
Corp oration) Seal on the nickel cadmium, nickel metal
hydride or lithium ion batteries (or battery packs) indicate
that the costs to recycle these batteries (or battery
packs) at the end of their useful life have already been paid by D
EWALT.
In some areas, it is illegal to place spent nickel cadmium, nickel metal
hydride or lithium ion batteries in the trash or municipal solid waste
stream and the RBRC program provides an environmentally conscious
alternative.
RBRC™ in cooperation with D
EWALT and other battery users, has
established programs in the United States and Canada to facilitate
the collection of spent nickel cadmium, nickel metal hydride or lithium
ion batteries. Help protect our environment and conserve natural
resources by returning the spent nickel cadmium, nickel metal hydride
or lithium ion batteries to an authorized D
EWALT service center or
to your local retailer for recycling. You may also contact your local
recycling center for information on where to drop off the spent battery.
RBRC™ is a registered trademark of the Rechargeable Battery
Recycling Corporation.
Important Safety Instructions for All
Battery Chargers
SAVE THESE INSTRUCTIONS: This manual contains important
safety and operating instruc tions for battery chargers.
Before using charger, read all instructions and cautionary markings
on charger, battery pack, and product using battery pack.
WARNING: Fire hazard. Never attempt to open the battery pack
for any reason. If battery pack case is cracked or damaged, do not
insert into charger. Do not crush, drop or damage battery pack. Do
not use a battery pack or charger that has received a sharp blow,
been dropped, run over or damaged in any way (i.e., pierced with a
nail, hit with a hammer, stepped on). Damaged battery packs should
be returned to service center for recycling.
WARNING: Fire hazard. Do not store or carry battery so
that metal objects can contact exposed battery terminals.
For example, do not place battery in aprons, pockets, tool boxes,
product kit boxes, drawers, etc., with loose nails, screws, keys, etc.
Transporting batteries can possibly cause fires if the battery
terminals inadvertently come in contact with conductive
materials such as keys, coins, hand tools and the like. The US
Department of Transportation Hazardous Material Regulations (HMR)
actually prohibit transporting batteries in commerce or on airplanes
(i.e., packed in suitcases and carry-on luggage) UNLESS they are
properly protected from short circuits. So when transporting individual
batteries, make sure that the battery terminals are protected and well
insulated from materials that could contact them and cause a short
circuit.
SPECIFIC SAFETY INSTRUCTIONS FOR LITHIUM ION (Li-Ion)
Do not incinerate the battery pack even if it is severely
damaged or is completely worn out. The battery pack can
explode in a fire. Toxic fumes and materials are created when
lithium ion battery packs are burned.
If battery contents come into contact with the skin,
immediately wash area with mild soap and water. If battery
liquid gets into the eye, rinse water over the open eye for 15minutes
or until irritation ceases. If medical attention is needed, the battery
electrolyte is composed of a mixture of liquid organic carbonates
and lithium salts.
5
English
WARNING: Shock hazard. Do not allow any liquid to get inside
charger. Electric shock may result.
CAUTION: Burn hazard. To reduce the risk of injury, charge only
D
EWALT rechargeable batteries. Other types of batteries may burst
causing personal injury and damage.
NOTICE: Under certain conditions, with the charger plugged in to the
power supply, the charger can be shorted by foreign material. Foreign
materials of a conductive nature such as, but not limited to, grinding
dust, metal chips, steel wool, aluminum foil, or any buildup of metallic
particles should be kept away from charger cavities. Always unplug the
charger from the power supply when there is no battery pack in the
cavity. Unplug charger before attempting to clean.
WARNING:
DO NOT attempt to charge the battery pack with any
chargers other than the ones in this manual. The charger and
battery pack are specifically designed to work together.
These chargers are not intended for any uses other than
charging D
EWALT rechargeable batteries. Any other uses may
result in risk of fire, electric shock or electrocution.
Do not expose charger to rain or snow.
Pull by plug rather than cord when disconnecting charger.
This will reduce risk of damage to electric plug and cord.
Make sure that cord is located so that it will not be stepped
on, tripped over, or otherwise subjected to damage or
stress.
Do not use an extension cord unless it is absolutely
necessary. Use of improper extension cord could result in risk of
fire, electric shock, or electrocution.
When operating a charger outdoors, use an extension cord
suitable for outdoor use. Use of a cord suitable for outdoor use
reduces the risk of electric shock.
An extension cord must have adequate wire size (AWG
or American Wire Gauge) for safety. The smaller the gauge
number of the wire, the greater the capacity of the cable, that is
16 gauge has more capacity than 18 gauge. An undersized cord
will cause a drop in line voltage resulting in loss of power and
overheating. When using more than one extension to make up the
total length, be sure each individual extension contains at least the
minimum wire size. The following table shows the correct size to
use depending on cord length and nameplate ampere rating. If in
doubt, use the next heavier gauge. The smaller the gauge number,
the heavier the cord.
Minimum Gauge for Cord Sets
Ampere Rating
Volts Total Length of Cord in Feet (meters)
120V 25 (7.6) 50 (15.2) 100 (30.5) 150 (45.7)
240V 50 (15.2) 100 (30.5) 200 (61.0) 300 (91.4)
More
Than
Not More
Than
AWG
0 6 18 16 16 14
610 18 16 14 12
10 12 16 16 14 12
12 16 14 12 Not Recommended
Do not place any object on top of charger or place the
charger on a soft surface that might block the ventilation
slots and result in excessive internal heat. Place the charger
in a position away from any heat source. The charger is ventilated
through slots in the top and the bottom of the housing.
Do not operate charger with damaged cord or plug.
Do not operate charger if it has received a sharp blow, been
dropped, or otherwise damaged in any way. Take it to an
authorized service center.
6
English
Do not disassemble charger; take it to an authorized service
center when service or repair is required. Incorrect reassembly
may result in a risk of electric shock, electrocution or fire.
Disconnect the charger from the outlet before attempting
any cleaning. This will reduce the risk of electric shock.
Removing the battery pack will not reduce this risk.
NEVER attempt to connect two chargers together.
The charger is designed to operate on standard 120V
household electrical power. Do not attempt to use it on any
other voltage. This does not apply to the vehicular charger.
Chargers
Your tool uses a DEWALT charger. Be sure to read all safety instructions
before using your charger. Consult the chart on the back cover of this
manual for compatibility of chargers and battery packs.
Charging Procedure (Fig. 1)
1. Plug the charger into an
A
FIG. 1
appropriate outlet
before inserting battery
pack.
2. Insert the battery pack
(A) into the charger,
as shown in Figure 1,
making sure the pack is
fully seated in charger.
The red (charging) light
will blink continuously
indicating that the
charging process has
started.
3. The completion of charge will be indicated by the red light
remaining ON continuously. The pack is fully charged and may be
used at this time or left in the charger.
Indicator Light Operation
DCB106
PACK CHARGING
PACK CHARGED
DCB107, DCB112
PACK CHARGING
PACK CHARGED
HOT/COLD DELAY
Charge Indicators
HOT/COLD PACK DELAY
DCB107, DCB112
The DCB107 and DCB112 chargers have a hot/cold delay feature.
When the charger detects a battery that is hot, it automatically delays
charging until the battery has cooled. When the charger detects a
battery that is cold, it automatically delays charging until the battery
has warmed.
The red light will continue to blink, but a yellow indicator light will
be illuminated during this operation. Once the battery has cooled,
the yellow light will turn off and the charger will resume the charging
procedure.
7
English
LEAVING THE BATTERY PACK IN THE CHARGER
The charger and battery pack can be left connected with the charge
indicator showing Pack Charged.
WEAK BATTERY PACKS: Weak batteries will continue to function
but should not be expected to perform as much work.
FAULTY BATTERY PACKS: This charger will not charge a faulty
battery pack. The charger will indicate faulty battery pack by refusing
to light or by displaying problem pack or charger.
NOTE: This could also mean a problem with a charger.
Wall Mounting
DCB107, DCB112
These chargers are designed to be wall mountable or to sit upright on
a table or work surface.
If wall mounting, locate the charger within reach of an electrical outlet.
Mount the charger securely using drywall screws at least 1" (25.4 mm)
long, screwed into wood to an optimal depth leaving approximately
7/32" (5.5 mm) of the screw exposed.
Important Charging Notes
1. Longest life and best performance can be obtained if the battery
pack is charged when the air temperature is between 65 °F and
75 °F (18–24 °C). DO NOT charge the battery pack in an air
temperature below +40 °F (+4.5 °C), or above +105 °F (+40.5 °C).
This is important and will prevent serious damage to the battery
pack.
2. The charger and battery pack may become warm to touch while
charging. This is a normal condition, and does not indicate a
problem. To facilitate the cooling of the battery pack after use,
avoid placing the charger or battery pack in a warm environment
such as in a metal shed, or an uninsulated trailer.
3. If the battery pack does not charge properly:
a. Check operation of receptacle by plugging in a lamp or other
appliance;
b. Check to see if receptacle is connected to a light switch which
turns power off when you turn out the lights;
c. Move charger and battery pack to a location where the
surrounding air temperature is approximately 65 °F–75 °F
(18–24 °C);
d. If charging problems persist, take the tool, battery pack and
charger to your local service center.
4. The battery pack should be recharged when it fails to produce
sufficient power on jobs which were easily done previously. DO
NOT CONTINUE to use under these conditions. Follow the
charging procedure. You may also charge a partially used pack
whenever you desire with no adverse affect on the battery pack.
5. Foreign materials of a conductive nature such as, but not limited
to, grinding dust, metal chips, steel wool, aluminum foil, or any
buildup of metallic particles should be kept away from charger
cavities. Always unplug the charger from the power supply when
there is no battery pack in the cavity. Unplug charger before
attempting to clean.
6. Do not freeze or immerse charger in water or any other liquid.
WARNING: Shock hazard. Don’t allow any liquid to get inside
charger. Electric shock may result.
CAUTION: Never attempt to open the battery pack for any reason.
If the plastic housing of the battery pack breaks or cracks, return to
a service center for recycling.
Storage Recommendations
1. The best storage place is one that is cool and dry away from direct
sunlight and excess heat or cold.
8
English
2. For long storage, it is recommended to store a fully charged
battery pack in a cool dry place out of the charger for optimal
results.
NOTE: Battery packs should not be stored completely depleted of
charge. The battery pack will need to be recharged before use.
SAVE THESE INSTRUCTIONS
FOR FUTURE USE
COMPONENTS (Fig. 2)
WARNING: Never modify the imaging thermometer or any part of
it. Damage or personal injury could result.
A. 12V Max* lithium-ion D. Micro SD card slot cover
battery pack E. Micro SD card slot
B. Handle F. Lens
C. Screen G. Lens cover
H.
Back Arrow Button: Press this button to navigate
backward.
I.
Select Button: Press this button to confirm a selection.
J.
Forward Arrow Button: Press this button to navigate
forward.
K.
Image Blend Adjust Button: Press this button to
change the percentage blend between the visual and
thermal images.
L.
Menu/Power Button: Press this button to power the
unit on (hold for 0.5 seconds) or off (hold for 3 seconds).
When the unit is powered on, press this button to view the
menu options.
M.
Photo Capture Button: Press this button for taking a
photo.
H
I
K
M
J
L
C
B
D, E
F, G
A
FIG. 2
INTENDED USE
The imaging thermometer measures radiated energy from an object's
surface and then uses those measurements to display an image and
estimate temperature.
9
English
OPERATION
Installing and Removing the Battery Pack
(Fig.4)
NOTE: Make sure your battery pack is fully charged.
To install the battery pack (A) into the tool handle, align the battery with
the rails inside the tool’s handle and slide it firmly into the handle until
you hear the lock snap into place.
P
A
FIG. 4
To remove the battery pack from the tool, press the release button (P)
and firmly pull the battery pack out of the tool handle. Insert it into the
charger as described in the charger section of this manual.
Getting Started (Fig. 2)
1. Slide lens cover (G) down to expose the lens.
Power On/Off
1. To turn on the imaging thermometer, push the menu/power button
(L) and hold for 0.5 seconds.
2. To turn off the imaging thermometer, push the menu/power button
(L) and hold for 3 seconds.
INITIAL SETUP
Date and Time Setup
The first time the imaging thermometer is powered on, it will prompt to
set the time and date. After the initial setup, the time and date can be
changed through the menu navigation.
Photos can be taken and then saved (bitmap format) on a micro SD
card.
The imaging thermometer can be used for inspections and trouble
shooting of electrical systems, HVAC, plumbing, mechanical
equipment, residential buildings or automotive systems.
The imaging thermometer is a professional tool. DO NOT let children
come into contact with the tool. Supervision is required when
inexperienced operators use this tool.
ASSEMBLY
Belt Hook (Fig.3) (Optional Accessory)
WARNING: To reduce the risk of serious personal injury, DO
NOT suspend tool overhead or suspend objects from the belt hook.
ONLY hang tool’s belt hook from a work belt.
WARNING: To reduce the risk of serious personal injury,
ensure the screw (N) holding the belt hook is secure.
IMPORTANT: When attaching or
N
O
FIG. 3
removing the belt hook, use only
the screw (N) that is provided.
The belt hook (O) can be
attached to either side of the
tool using only the screw (N)
provided, to accommodate left-
or right-handed users. If the hook
is not desired at all, it can be removed from the tool.
To move belt hook, remove the screw (N) that holds the belt hook in
place then reassemble on the opposite side.
10
English
1. Press the forward (J) or back (H) arrow to highlight the field to
change.
2. Press the select button (I) to activate the field. The field will turn
green.
3. Press the forward (J) or back (H) arrow to change the activated
field.
4. Press the select button (I) to save the changes.
5. Repeat the steps above to change the remaining fields.
6. Press the menu/power button (L) to exit.
BASIC OPERATION
Main Viewing Screen
The main screen includes several sections:
Q. Scanned area image
R. Temperature measurement at center of image (+)
S. Emissivity setting
T. Battery fuel gauge
U. Temperature color scale
R
T
S
Q
U
Image Blend
The DCT416 Imaging Thermometer has the ability to display both a
visual image and an infrared image. The images can also be blended
on the display to provide an overlay of the thermal image on top of the
visual image. A blended image can be helpful in diagnosing trouble
spots or communicating with customers.
To change the blend setting, push the image blend adjust button
(K). The image blend can be pushed repeatedly to cycle through the
following options for display settings:
100% Visual
75% Visual, 25% Thermal
50% Visual, 50% Thermal
25% Visual, 75% Thermal
100% Thermal
Take and Store Photos
Make sure a micro SD card is installed in order to save a photo. Open
micro SD card slot cover (D) and insert the micro SD card into the
slot (E).
11
English
E
D
1. Push photo capture button (M).
2. The displayed image will freeze for 3 seconds in order to review
the photo.
3. Press the forward (J) or back (H) arrow to highlight save to SD
card or delete.
4. Press the select button (I) to confirm selection.
5. After completion of save or delete, the imaging thermometer will
automatically return to the main viewing screen.
NOTE: If no SD card is installed or if there is a problem with the SD
card, the below communication will appear.
NOTE: If the SD card is full, the below communication will appear.
MENU OPTIONS
NOTE: At any time, pushing the menu/power button (L) will return to
the previous menu.
12
English
To View Photos
1. Press the menu/power button (L).
2. Press the forward (J) or back (H) arrow to highlight the folder
option in the menu.
3. Press the select button (I) to confirm selection.
4. Press the forward (J) or back (H) arrow to scroll through saved
images.
5. Press the select button (I) to go to the delete sub-menu.
6. Press the forward (J) or back (H) arrow to highlight save to SD
card or delete.
7. Press the select button (I) to confirm selection.
8. After completion of save or delete, the imaging thermometer will
automatically return to the next sequential image.
Emissivity
Emissivity describes the energy-emitting characteristics of materials.
Most organic materials and painted or oxidized surfaces have an
emissivity of about 0.95 which is the default setting. It is recommended
to compensate for inaccurate readings that may result from measuring
materials with low emissivity values such as shiny metal surfaces. Cover
these surfaces with masking tape or flat black paint (<148˚C/300˚F)
and use the default (0.95) setting. Allow time for the tape or paint
to reach the same temperature as the surface beneath it and then
measure the temperature of the tape or painted surface.
If you cannot paint or use tape, then you can compensate your
measurements with the emissivity selector. Even with the adjustable
emissivity, it can be difficult to get a completely accurate infrared
measurement of a target with a shiny or metallic surface. Experimentation
may be required to benchmark temperatures, and experience will help
you choose the best setting for specific measurements.
The imaging thermometer has emissivity adjustable from 0.1 to 1.0
in increments of 0.01. Refer to the Emissivity Table Value table
in this manual. The reference to emissivity settings in the table are
suggestions for typical situations and your particular situation may
differ.
NOTE: Calibration of this product was performed at 0.95 emissivity.
13
English
NOMINAL EMISSIVITY VALUE
MATERIAL VALUE MATERIAL VALUE
Carbon-filled surface 0.98 Copper, heavily oxidized 0.78
Frost crystals 0.98 Cloth, cotton 0.77
Human skin 0.98 Sand 0.76
Slate 0.97 Silica, unglazed 0.75
Water, distilled 0.96 Iron, oxidized at 100˚C 0.74
Ice, smooth 0.96 Coating No. C20A 0.73
Soil, saturated with water 0.95 Basalt 0.72
Carbon candle soot 0.95 Carbon, graphitized at
500˚C
0.71
Glass, polished plate 0.94 Red Rust 0.70
Paint, oil 0.94 Iron sheet, heavily rusted 0.69
Brick, red 0.93 Water 0.67
Paper, white bond 0.93 Black loam 0.66
Concrete 0.92 Cement, white 0.65
Soil, dry 0.92 Iron cast, oxidized 0.64
Plaster, rough coat 0.91 Lead, oxidized at 1100˚C 0.63
Wood, planed oak 0.90 Zirconia on inconel 0.62
Earthenware, glazed 0.90 Cu-Zn, brass oxidized 0.61
Snow, granular 0.89 Inconel sheet at 760˚C 0.58
Silica, glazed 0.88 Marble, smooth white 0.56
Cuprous Oxide at 38˚C 0.87 All anodized chromic acid 0.55
Emery Corundum 0.86 Iron cast, polished 0.21
Snow 0.85 Brass, rubbed 80 grit emery 0.20
Stainless, oxidized at
800˚C
0.85 Stainless steel, 18-8 buffed 0.16
Iron, oxidized at 500˚C 0.84 Aluminium as received 0.09
Cuprous Oxide at 260˚C 0.83 Steel, polished 0.07
Snow, fine particles 0.82 Aluminium, polished sheet 0.05
Brass, unoxidized 0.81 Copper, polished 0.05
Glass, convex D 0.80 Brass, highly polished 0.03
Steel, oxidized 0.79
To Change Emissivity
1. Press the menu/power button (L).
2. Press the forward (J) or back (H) arrow to highlight the emissivity
option in the menu.
3. Press the select button (I) to confirm selection.
4. Press the forward (J) or back (H) arrow to adjust the emissivity
setting. The emissivity can be adjusted in increments of 0.01 from
0.10 to 1.00.
5. Press the select button (I) to confirm the emissivity setting.
6. After saving the emissivity setting, the imaging thermometer will
automatically return to the main menu screen.
Background Temperature
For more accurate temperature measurements, it is recommended
to set the background (or reflected temperature). This is especially
important when the object being measured is at a significantly different
temperature than ambient or if the object being measured has a low
emissivity.
Setting the background temperature will help compensate for the
radiation from the surroundings.
14
English
To Change Background Temperature
1. Press the menu/power button (L).
2. Press the forward (J) or back (H) arrow to highlight the
background temperature option in the menu.
3. Press the select button (I) to confirm selection.
4 Press the forward (J) or back (H) arrow to adjust the background
temperature. The background temperature can be adjusted in
1degree increments.
5. Press the select button (I) to confirm the background
temperature setting.
6. After saving the background temperature setting, the imaging
thermometer will automatically return to the main menu screen.
To Change Color Palette
1. Press the menu/power button (L).
2. Press the forward (J) or back (H) arrow to highlight the color
palette option in the menu.
3. Press the select button (I) to confirm selection.
4. Press the forward (J) or back (H) arrow to scroll through the color
palette options. The five palette choices include: Ironbow, White
Hot, Black Hot, Rainbow and High Contrast.
5. Press the select button (I) to confirm the color palette setting.
6. After saving the color palette setting, the imaging thermometer
will automatically return to the main menu screen.
To Change the Tracking Setting
When the tracking feature is on, the imaging thermometer will locate
the hottest (red o) and coldest (blue o) spot in the displayed area. The
imaging thermometer can be moved to align the center measurement
spot (+) to the desired location.
NOTE: The displayed temperature always corresponds to the
center(+).
1. Press the menu/power button (L).
2. Press the forward (J) or back (H) arrow to highlight the tracking
option in the menu.
15
English
3. Press the select button (I) to confirm selection.
4. Press the forward (J) or back (H) arrow to turn on or off the
tracking feature.
5. Press the select button (I) to confirm the tracking feature setting.
6. After saving the tracking feature setting, the imaging thermometer
will automatically return to the main menu screen.
To Set Date and Time
1. Press the menu/power button (L).
2. Press the forward (J) or back (H) arrow to highlight the date and
time option in the menu.
3. Press the select button (I) to confirm selection.
4. Press the forward (J) or back (H) arrow to highlight the field to
change.
5. Press the select button (I) to activate the field. The field will turn
green.
6. Press the forward (J) or back (H) arrow to change the activated
field.
7. Press the select button (I) to save the changes.
8. Repeat the steps above to change the remaining fields.
9. Press the menu/power button (L) to exit.
To View Information
1. Press the menu/power button (L).
16
English
2. Press the forward (J) or back (H) arrow to highlight the information
option in the menu.
3. Press the select button (I) to confirm selection
4. The imaging thermometer will display the software version.
5. Press the menu/power button (L) to exit.
To Change Temperature Scales
1. Press the menu/power button (L).
2. Press the forward (J) or back (H) arrow to highlight the C / F option
in the menu.
3. Press the select button (I) to confirm selection
4. Press the forward (J) or back (H) arrow to highlight either C or F.
5. Press the select button (I) to confirm selection.
6. After saving the temperature scale setting, the imaging
thermometer will automatically return to the main menu screen.
Return to the Main Viewing Screen
1. Press the menu/power button (L).
2. Press the forward (J) or back (H) arrow to highlight the home
option in the menu.
3. Press the select button (I) to confirm selection.
To Download Images to Computer
The imaging thermometer records both the thermal and visual image
for each saved photo. Images are saved in bitmap format.
The micro SD card can be transferred to a computer to view the
images.
Report Writing Software
The imaging thermometer includes report writing software with your
purchase. You can also download the software from www.dewalt.
com.
17
English
To Turn Off Imaging Thermometer
1. To turn off the imaging thermometer, push the menu/power
button (L) and hold for 3 seconds. The imaging thermometer will
also automatically turn off after 10 minutes of non-use.
2. Slide lens cover (G) up to protect lens when not in use.
Operating Tips
• Use only DEWALT 12V Max* lithium-ion battery.
Ensure the D
EWALT battery is in good working condition. If the
battery fuel gauge on the screen is empty, the battery needs to be
recharged.
Avoid sudden changes in temperature such as when entering or
leaving a heated building on a cold day as this can cause condensation
inside the imaging thermometer. To prevent condensation, place the
imaging thermometer in the kitbox or a plastic bag before exposing it
to sudden changes in temperature.
MAINTENANCE
Cleaning
WARNING: Blow dirt and dust off with clean, dry air at least once
a week. To minimize the risk of eye injury, always wear ANSI Z87.1
approved eye protection when performing this.
WARNING: Do not apply solvents to the lens as this may cause
damage. Do not clean the infrared lens too vigorously as this can
damage the delicate anti-reflective coating.
WARNING: Never use solvents or other harsh chemicals for
cleaning the non-metallic parts of the tool. These chemicals may
weaken the plastic materials used in these parts. Use a cloth
dampened only with water and mild soap. Never let any liquid get
inside the tool; never immerse any part of the tool into a liquid.
CHARGER CLEANING INSTRUCTIONS
WARNING: Shock hazard. Disconnect the charger from the AC
outlet before cleaning. Dirt and grease may be removed from the
exterior of the charger using a cloth or soft non-metallic brush. Do
not use water or any cleaning solutions.
Troubleshooting
Make sure the lens cover (G) is open.
Make sure the 12V Max* lithium-ion battery is charged.
Make sure the battery is installed on the handle set when in use.
If the screen freezes, remove the 12V Max* lithium-ion battery to
reset the unit. Reinsert the battery pack and press the power on
button.
KEY NOTES IF HAVING TROUBLE TAKING MEASUREMENT
1. Make sure to apply masking tape or flat black paint to surfaces
that are highly reflective (use the default 0.95 emissivity setting).
2. Make sure to have the correct emissivity for the material you
are testing. Refer to the Emissivity section and the Nominal
Emissivity Value table in this manual.
3. Clean the material before testing if there is heavy dirt, grease, etc.
Accessories
WARNING: Since accessories, other than those offered by
D
EWALT, have not been tested with this product, use of such
accessories with this tool could be hazardous. To reduce the risk of
injury, only D
EWALT recommended accessories should be used with
this product.
Recommended accessories for use with your tool are available
at extra cost from your local dealer or authorized service center.
If you need assistance in locating any accessory, please contact
D
EWALT Industrial Tool Co., 701 East Joppa Road, Baltimore, MD
21286, call 1-800-4-D
EWALT (1-800-433-9258) or visit our website
www.dewalt.com.
18
English
Please contact DEWALT Industrial Tool Co., 701 East Joppa Road,
Baltimore, MD 21286, call 1-800-4-D
EWALT (1-800-433-9258) or visit
our website www.dewalt.com.
Repairs
The charger and battery pack are not serviceable. There are no
serviceable parts inside the charger or battery pack.
To assure product SAFETY and RELIABILITY, repairs, maintenance
and adjustment should be performed by a D
EWALT factory service
center, a D
EWALT authorized service center or other qualified service
personnel. Always use identical replacement parts.
Register Online
Thank you for your purchase. Register your product now for:
WARRANTY SERVICE: Registering your product will help you
obtain more efficient warranty service in case there is a problem
with your product.
CONFIRMATION OF OWNERSHIP: In case of an insurance
loss, such as fire, flood or theft, your registration of ownership will
serve as your proof of purchase.
FOR YOUR SAFETY: Registering your product will allow us to
contact you in the unlikely event a safety notification is required
under the Federal Consumer Safety Act.
Register online at www.dewalt.com/register.
Three Year Limited Warranty
DEWALT will repair, without charge, any defects due to faulty materials
or workmanship for three years from the date of purchase. This
warranty does not cover part failure due to normal wear or tool abuse.
For further detail of warranty coverage and warranty repair information,
visit www.dewalt.com or call 1-800-4-D
EWALT (1-800-433-9258).
This warranty does not apply to accessories or damage caused where
repairs have been made or attempted by others. This warranty gives
you specific legal rights and you may have other rights which vary in
certain states or provinces.
In addition to the warranty, D
EWALT tools are covered by our:
1 YEAR FREE SERVICE
D
EWALT will maintain the tool and replace worn parts caused by
normal use, for free, any time during the first year after purchase.
2 YEARS FREE SERVICE ON D
EWALT BATTERY PACKS
DC9071, DC9091, DC9096, DC9280, DC9360, DC9180, DCB120,
DCB201, DCB203, DCB207 and DCB127
3 YEARS FREE SERVICE ON D
EWALT BATTERY PACKS
DCB200, DCB204
D
EWALT BATTERY PACKS
Product warranty voided if the battery pack is tampered with in any
way. D
EWALT is not responsible for any injury caused by tampering
and may prosecute warranty fraud to the fullest extent permitted by
law.
90 DAY MONEY BACK GUARANTEE
If you are not completely satisfied with the performance of your
DEWALT Power Tool, Laser, or Nailer for any reason, you can return it
within 90 days from the date of purchase with a receipt for a full refund
– no questions asked.
LATIN AMERICA: This warranty does not apply to products sold
in Latin America. For products sold in Latin America, see country
specific warranty information contained in the packaging, call the local
company or see website for warranty information.
FREE WARNING LABEL REPLACEMENT: If your warning labels
become illegible or are missing, call 1-800-4-D
EWALT (1-800-433-
9258) for a free replacement.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68

DeWalt DCT416S1 Manuel utilisateur

Catégorie
Thermomètres corporels numériques
Taper
Manuel utilisateur

dans d''autres langues