Ideal Auto DMM Mode d'emploi

Catégorie
Testeurs de réseau câblé
Taper
Mode d'emploi
#61-484
#61-486
480 Series Digital Multimeter
Instruction Manual
61-486
Volt SenseRange Min Max
Press 2 Sec
PEAK HOLD
Smart
HOLD
A
Auto
V
LoZ
OFF
MAX
10A
FUSED
MAX
600mA
FUSED
600V CAT IV
1000V CAT III
mA COM
V Ω
TRUE RMS
Hz
Hz
V
ac+dc
ac+dc
ac+dc
ac+dc
V
mV
mA
A
Ω
2
Register your product and access more information at
www.idealindustries.com
Read First: Safety Information
Understand and follow operating instructions carefully. Use the
meter, test leads and all accessories only as specified in this manual;
otherwise, the protection provided by the meter can be impaired.
WARNING
To avoid possible electric shock, personal injury or death,
follow these guidelines:
Do not use if meter appears damaged. Visually inspect the meter
to ensure case and jaws are not cracked.
Inspect and replace test leads if insulation is damaged, metal is
exposed, or probes are cracked. Pay particular attention to the
insulation surrounding the connectors.
Always ensure the meter, test leads and all accessories meet
or exceed the measurement category required in the working
environment. (i.e. CAT rating)
Note that the measurement category and voltage rating of
combinations of the meter, the test leads, and the accessories is
the lowest of the individual components.
Do not use meter if it operates abnormally as protection maybe
impaired.
Do not use during electrical storms or in wet weather.
Do not use around explosive gas, dust, vapor, amperage or in
damp or wet environments.
Do not apply more than the rated voltage to the meter.
Remove the test leads from the input jacks before measuring
current.
Replace battery as soon as battery indicator appears to avoid
false readings.
Remove the test leads from the meter prior to removing battery cover
.
Do not use without the battery and battery cover properly installed.
Do not attempt to repair this unit as it has no user-serviceable parts
.
Use the proper terminals, functions and range for your measurements
.
Never ground yourself when taking electrical measurements.
Connect the black common lead to ground or neutral before
applying the red test lead to potential voltage. Disconnect the red
test lead from the voltage first.
Keep fingers behind the guard rings of the probe tips.
Voltages exceeding 30VAC or 60VDC pose a shock hazard so use
caution.
CAUTION
To protect yourself, think “Safety First”:
Comply with local and national safety codes.
33
Use appropriate personal protective equipment such as face
shields, insulating gloves, insulating boots, and/or insulating mats.
Before each use:
- Perform a continuity test by touching the test leads together to
verify the functionality of the battery and test leads.
- Use the 3 Point Safety Method. (1) Verify meter operation by
measuring a known voltage. (2) Apply meter to circuit under
test. (3) Return to the known live voltage again to ensure
proper operation.
Always work with a partner.
Symbols as marked on the meter and instruction manual
Unsafe Voltage
To alert you to the presence of a potentially hazardous
voltage, when the Tester detects a voltage
30 V or a
voltage overload (OL) in V, mV. The “ “ symbol is
displayed and High voltage indicator is activated.
Risk of Danger. Important Information. See Manual.
Hazardous voltage. Risk of electrical shock.
Application around and removal from Hazardous Live
conductors is permitted.
AC (Alternating Current)
DC (Direct Current)
Earth Ground
CAT II
Measurement Category II applies to test and measuring cir-
cuits connected directly to utilization points (socket outlets
and similar points) of the low-voltage MAINS installation
CAT III
Measurement Category III applies to measuring circuits
connected to the distribution part of the building’s low-
voltage MAINS installation
CAT IV
Measurement Category IV applies to test and measuring
circuits connected at the source of the building’s low-
voltage MAINS installation
~
...
4
61-486
Volt SenseRange Min Max
Press 2 Sec
PEAK HOLD
Smart
HOLD
A
Auto
V
LoZ
OFF
MAX
10A
FUSED
MAX
600mA
FUSED
600V CAT IV
1000V CAT III
mA COM
V Ω
TRUE RMS
Hz
Hz
V
ac+dc
ac+dc
ac+dc
ac+dc
V
mV
mA
A
Ω
Meter Description
Front Panel Illustration
1. LCD display : 6000 counts
2. Push-buttons.
3. Rotary switch to turn the Power On / Off and select the
function.
4. Input Terminal for A.
5. Input Terminal for V,Ω, , Hz, °C/F° functions.
6. Common (Ground reference) Input Terminal.
7. Input Terminal for mA.
1 Display
2 Buttons
3 Rotary
Switch
5 V, Ω,
,
C°/F°
Input
6 Common
Input
7 mA Input
4 A Input
5
Features
6000 count digital display
62 segment bar graph
Extra large scale display with white backlight
True RMS
0.08% basic DCV accuracy
Automatic AC/DC voltage detect with low impedance
(Auto-V LoZ)
VoltSense (Non-Contact Voltage detect)
Smart Data hold
Peak Hold (1ms) (61-486 only)
Min/Max function
AC+DC function
Frequency counter on AC mode
Capacitance measurement
Temperature (61-486 only)
Low battery indicator with segments
Auto Power off (20 minutes)
Shock proof from 4 feed drops
CAT IV 600V/CAT III 1000V Safety standard
Unpacking & Inspection
Upon removing your new Digital Multimeter from its
packaging, you should have the following items:
1. IDEAL 61-484/61-486 Digital Multimeter
2. Test leads, set (one black, one red)
3. Temperature Probe (61-486 only)
4. User Manual
5. Carrying Case
6. One 9V Battery (installed)
Test Leads
Guard ring
6
Making Basic Measurements
Preparation and Caution Before Measurement
: Observe the rules of Warnings and Cautions
CAUTION
When connecting the test leads to the DUT (Device
Under Test) connect the common test leads before
connecting the live test leads. When removing
the test leads, remove the live test leads before
removing the common test leads.
Measuring AC / DC Voltage
Turn the rotary switch and press the Function button to select
the measuring function.
7
Measuring AC/DC Current
Turn the rotary switch and press the Function button to select
the measuring function.
Measuring Frequency
Turn the rotary switch and press the Function button to select
the measuring function.
Disconnect
Press the function
button to select the
measuring function.
8
Measuring Resistance/Capacitance
Turn the rotary switch and press the Function button to select
the measuring function.
Measuring Continuity/Diode
Turn the rotary switch and press the Function button to select
the measuring function.
Capacitance
Capacitance
Resistance
Resistance
9
Measuring Temperature °F / °C (61-486 only)
Turn the rotary switch and press the Function button to select
the measuring function. (°C / °F)
10
Press button > 1sec to Auto Range Mode.
AC
Switch
Position
Hz
ac+dc
ac+dc
ac+dc
ac+dc
ac+dc
Function
Press
FC
Using the Function
Function Button
Press the Function button to change the function on the same
switch position.
RANGE Button
11
MIN/MAX
The MAX/MIN mode records the min. and max. input values.
When the input goes below the recorded min. value or above
the recorded max. value, the meter records the new value.
Press Hold button to pause the recording.
Peak HOLD (61-486 only)
In the Peak Hold function ,the meter records the peak min.
value and the peak max. value when the inputs goes below
the recorded peak min. value or above the recorded peak
max. value ,the meter records the new value . Press Hold
button to pause the recording.
Press
button over 1 sec.
to exit this function
Min. Reading
Max. Reading
Present Reading
Press
button over 1 sec.
then exit this function
Min. Reading
Max. Reading
Press
2 sec.
Present Reading
12
Smart HOLD
The meter will beep continuously and the display will flash
if the measured signal is larger than the display reading by
50 counts. (However, it cannot detect across the AC and DC
Voltage /Current).
VoltSense
Keep the VoltSense button down to activate the VoltSense
function.
Caution
The number of dashes displaying on the display indicates the
electric field intensity. If no indication, voltage could still be
present. Always verify with leads.
13
Backlight
Press the Backlight button to turn the backlight on/off.
Disable Auto Power Off
Wake-up the meter by dialing the switch or pressing any
button.
Auto Power Off Disable
Turn the rotary switch to the off position, then press the
Function button down while turning on the meter.
After idle 20 min.
2
1
14
Testing LCD Monitor
Turn the rotary switch to the off position, then press the
Smart-HOLD button down while turning on the meter.
Fuse Replacement
2
1
Fuse 440mA (1000V)
Battery Cover
Fuse 11A (1000V)
Rear Case
15
Low Battery and Battery Replacement
Replace the battery as soon as the low battery indicator
appears to avoid false readings. Refer to the following figure
to replace the battery.
Caution
Remove test leads from the Meter before opening the battery
cover or meter case.
9V Battery
Ba
ttery Cover
Screw
Specifications
General Specifications
Maximum voltage applied to any terminal:
1000 Vac rms or 1000 Vdc. rms
Display: 6000 counts.
Polarity Indication:
Automatic, positive implied, negative indicated.
Overrange Indication: OL
Battery Life: 150hours ALKALINE Battery (No Backlight)
Low Battery Indication:
Voltage drops below operating voltage, will flash.
Power Requirement: 9V battery
Auto Power Off: 20 minutes.
Operating Temperature: -10 ~10°C
10°C ~ 30°C (<80% RH),
30°C ~ 40°C (<75% RH),
40°C ~ 50°C (<45%RH)
16
CAT Application to Field
I The circuits not connected to mains.
II The circuits directly connected to Low-voltage installation.
III The building installation.
IV The source of the Low-voltage installation.
N12966
Storage Temperature:
-20°C to 60°C , 0 to 80% R.H. (batteries not fitted)
Temperature Coefficient:
0.15 x (Spec.Accy) / °C, < 18°C or > 28°C .
Measure: Samples 3 times per second.
Altitude: 6561.7 ft (2000m)
Safety Certification: Complies with EN61010-1,
UL61010-1, IEC 61010-1, CAT IV 600V, CAT III 1000V
Double Insulation
Instrument has been evaluated and complies with insulation
category IV (overvoltage category IV). Pollution degree 2 in
accordance with IEC-644. Indoor use.
Compliance to EN 61557: IEC61557-1, IEC61557-2,
IEC61557-4, IEC61557-10
Weight: 460g (including battery)
Dimensions (W x H x D):
94mm x190mm x 48mm with holster.
Accessories Included: 9V Battery (installed), Test leads
(TL-484) and user manual.
EMC: EN 61326-1
Shock vibration: Sinusoidal vibration per
MIL-PRF- 28800F (5 ~ 55 Hz, 3g max.)
Drop Protection: 4 ft. drop onto hardwood over concrete
floor.
17
Electrical Specifications
Accuracy is ±(% reading + number of digits) at 23°C ± 5°C
< 80%RH.
(1) Voltage
Range Resolution
For 61-484
Accuracy
For 61-486
Accuracy
60.00mV
DC
0.01mV ± (0.08% + 10d)
600.0mV
DC
0.1mV ± (0.1% + 2d) ± (0.08% + 2d)
6.000V
DC
0.001V ± (0.09% + 2d) ± (0.08% + 2d)
60.00V
DC
0.01V ± (0.09% + 2d) ± (0.08% + 2d)
600.0V
DC
0.1V ± (0.09% + 2d) ± (0.08% + 2d)
1000V
DC
1V ± (0.09% + 2d) ± (0.08% + 2d)
60.0mV
AC
0.01mV ± (1.20% + 5d)
600.0mV
AC
0.1mV ± (1.5% + 5d) ± (1.20% + 5d)
6.000V
AC
0.001V ± (1.0% + 3d) ± (0.80% + 5d)
60.00V
AC
0.01V ± (1.0% + 3d) ± (0.80% + 5d)
600.0V
AC
0.1V ± (1.0% + 3d) ± (0.80% + 5d)
1000V
AC
1V ± (1.0% + 3d) ± (0.80% + 5d)
Input Protection : 1000V
DC
or 1000V
AC
rms
AC Frequency Response : 50Hz ~ 1KHz
Input Impedance : 10MΩ, <100pF
AC Conversion Type :
AC conversions are ac-coupled, true rms responding,
calibrated to the sine wave input.
For non-sine wave add the following Crest Factor corrections:
For Crest Factor of 1.4 to 2.0, add 1.0% to accuracy.
For Crest Factor of 2.0 to 2.5, add 2.5% to accuracy.
For Crest Factor of 2.5 to 3.0, add 4.0% to accuracy.
18
(2) Auto-V
Range Resolution
For 61-484
Accuracy
For 61-486
Accuracy
600.0V
AC
0.1V
± (1.0% + 3d) ± (0.80% + 3d)
1000V
AC
1V
600.0V
AC
0.1V
1000V
AC
1V
Input Protection : 1000VDC or 1000VAC rms
AC Frequency Response : 50Hz ~ 1KHz
Input Impedance : Approx. 3kΩ.
AC Conversion Type :
Conversion type and additional specification are same as
voltage function.
(3) Current
Range Resolution
For 61-484
Accuracy
For 61-486
Accuracy
60.00mA
DC
0.01mA ± (1.0% + 3d) ± (0.08% + 3d)
600.0mA
DC
0.1mA ± (1.0% + 3d) ± (0.08% + 3d)
6.000a
DC
0.001A ± (1.0% + 3d) ± (0.08% + 3d)
10.00A
DC
0.01A ± (1.0% + 3d) ± (0.08% + 3d)
60.0mA
AC
0.01mA ± (1.5% + 3d) ± (1.2% + 3d)
600.0mA
AC
0.1mA ± (1.5% + 3d) ± (1.2% + 3d)
6.000A
AC
0.001A ± (1.5% + 3d) ± (1.2% + 3d)
10.00A
AC
0.01A ± (1.5% + 3d) ± (1.2% + 3d)
Input Protection :
Equipped with High Energy Fuse.
440mA, 1000V AC/DC 10KA Fuse for mA input.
11A, 1000V AC/DC 20KA Fuse for A input.
Max. Measuring Time : 3 minutes for A input, 10 minutes
for mA input.
Rest time 20 minutes min.
AC Conversion Type :
Conversion type and additional specification are same as
volt-age function.
AC Frequency Response : 50Hz ~ 1KHz
19
(4) Peak Hold (for 61-486 only) : Specified accuracy
±150d.
(5) Resistance
Range Resolution Accuracy
600.0Ω 0.1Ω ± (0.08% + 5d)
6.000KΩ 0.001KΩ
± (0.08% + 2d)
60.00KΩ 0.01KΩ
600.0KΩ 0.1KΩ
6.000MΩ 0.001mΩ
40.00MΩ* 0.01MΩ ± (1.0% + 5d)
Input Protection : 1000VDC or 1000VAC rms
Max. Open Circuit Voltage :
Approx. 2.5V for 600Ω & 6kΩ Range.
Approx. 0.6V for others.
Max. Test Current : Approx. 0.1mA.
(6) Continuity Check
Range Resolution Accuracy
600.0Ω 0.1Ω ± (0.8% + 5d)
Input Protection : 1000VDC or 1000VAC rms
Max. Open Circuit Voltage : Approx. 2.5V
Max. Test Current : Approx. 0.1mA
Continuity Threshold : <30Ω Beep On.
>100Ω Beep OFF.
Continuity Indicator : 2.7KHz Tone Buzzer
(7) Diode Test
Range Resolution Accuracy
2.000V 1mV ± (1.5% + 2d)
Input Protection : 1000VDC or 1000VAC rms
Max. Open Circuit Voltage : Approx. 2.5V
Max.Test Current : Approx. 0.4mA
20
(8) Capacitance
Range Resolution Accuracy
1.000μF 0.001μF
± (1.2% +2d)
10.00μF 0.01μF
100.0μF 0.1μF
1.000mF 0.001mF
10.00mF 0.01mF
Input Protection : 1000VDC or 1000VAC rms
Max. Measuring Time : 0.7 sec for 1nF~1mF
3 sec for 1mF~10mF
(9) Frequency Counter
Range Resolution Accuracy
100.00 Hz 0.1 Hz
± (0.1% +2d)
1000.0 Hz 0.1 Hz
10.000 KHz 0.001 KHz
100.00 KHz 0.01 KHz
Input Protection : 1000VDC or 1000VAC rms
Min. Frequency : 1Hz
Sensitivity : > 5.0Vp-p (for ACV 1HZ ~ 10kHz).
> 10Vp-p (for ACV 10kHZ ~ 100kHz)
> 2mAp-p (for ACmA)
> 0.2Ap-p (for ACA)
(10) Temperature (For 61-486 only)
Range Resolution Accuracy*
-40.0°C ~ 400°C 0.1°C ± (1.0% + 10d)
-40.0°F ~ 752°F 0.1°F ± (1.0% + 18d)
Input Protection : 1000VDC or 1000VAC rms
* Does not include accuracy of the thermocouple probe.
* Accuracy specification assumes surrounding temperature
stable to ± 1°C. For surrounding temperature changes of
± 5°C, rated accuracy applies after 2 hours.
Note : The AC+DC True RMS value might be over the
selected range since the AC signal may add on the DC level.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72

Ideal Auto DMM Mode d'emploi

Catégorie
Testeurs de réseau câblé
Taper
Mode d'emploi

dans d''autres langues