IHP.us.com 1
NCVM-42O GAS CONVERSION KIT, MILLIVOLT, PROPANE/LP GAS TO NATURAL GAS
[FOR USE WITH APPLIANCE MODELS ODYSSEY42, VRE3042, SAVANNAH42]
P/N 127208-01
Rev. B, 03/2017
HEARTH PRODUCTS
KITS AND ACCESSORIES
Cat. No. Model Description
F1137 NCVM-42O LP-NG Gas Conversion Kit
NCVM-42O GAS CONVERSION KIT
PROPANE GAS TO NATURAL GAS
KIT CONTENTS
1 ea. Pilot Orifi ce NG (#51)
1 ea. Main Burner Orifi ce NG (#29)
1 ea. Air-Mixer Brass NG
1 ea. Gas Valve Regulator NG
1 ea. Conversion Label, English
1 ea. Conversion Label, French
1 ea. Conversion Information Label
1 ea. Instruction Sheet
REQUIRED TOOLS AND SUPPLIES
7/8” Open End Wrench or Adjustable Wrench
3/4” Open End Wrench or Adjustable Wrench
Torx T20 or Slotted Screwdriver
5/32” Allen Wrench
#2 Short Phillips Screwdriver
Thread Sealant (Resistant to Propane/LP)
TURN OFF THE GAS SUPPLY TO THE APPLIANCE. DISCONNECT
ELECTRICAL POWER SUPPLY.
READ ALL THE STEPS BEFORE STARTING THE CONVERSION. IN-
STALLER NOTICE: THESE INSTRUCTIONS MUST BE LEFT WITH THE
APPLIANCE.
When installing gas components use pipe joint compound or
Tefl on tape on all pipe fi ttings before installing (Do not use pipe
joint compounds on fl are fi ttings).
THE APPLIANCE MUST BE OFF AND COLD BEFORE PERFORMING
THE GAS CONVERSION.
ALL WARNINGS, PRECAUTIONS AND INSTRUCTIONS IN THE INSTAL-
LATION AND OPERATION MANUAL PROVIDED WITH THE APPLIANCE
APPLY TO THESE INSTRUCTIONS.
GENERAL INFORMATION
Gas conversion kits are available to adapt the appliance from the
use of one type of gas to the use of another. These kits contain all
the necessary components needed to complete the task including
labeling that must be affi xed to ensure safe operation.
WARNING
This conversion kit shall be installed by a qualifi ed
service agency in accordance with the manufac-
turer's instructions and all applicable codes and
requirements of the authority having jurisdiction. If
the information in these instructions is not followed
exactly, a fi re, explosion or production of carbon
monoxide may result causing property damage,
personal injury or loss of life. The qualifi ed service
agency performing this installation is responsible
for the proper installation of this kit and assumes
responsibility for this conversion. The installation
is not proper and complete until the operation of the
converted appliance is checked as specifi ed in the
manufacturers instructions supplied with the kit.
IMPORTANT LE CANADA SEULEMENT
La conversion devra être effectuée conformément aux
recommandations des autorités provinciales ayant
juridiction et conformément aux exigences du code
d'installation CAN/CSA B149.1.
IMPORTANT CANADA
The conversion shall be carried out in accordance with
the requirements of the provincial authorities having
jurisdiction and in accordance with the requirements
of the CAN/CSA B149.1 Installation code.
AVERTISSEMENT
Cet équipement de conversion sera installé par
une agence qualifi ée de service conformément aux
instructions du fabricant et toutes exigences et codes
applicables de l'autorisés avoir la juridiction. Si
l'information dans cette instruction n'est pas suivie
exactement, un feu, explosion ou production de
protoxyde de carbone peut résulter le dommages
causer de propriété, perte ou blessure personnelle de
vie. L'agence qualifi ée de service est esponsable de
l'installation propre de cet équipment. L'installation
n'est pas propre et compléte jusqu'à l'opération de
l'appareil converti est chéque suivant les critères
établis dans les instructions de propriétaire provi-
sionnées avec l'équipement.