Furrion F2GWH Manuel utilisateur

Taper
Manuel utilisateur
This drawing contains proprietary information and trade secrets of The Furrion Company, Inc.
Unauthorized use or copying is prohibited.
METRIC
[INCH]
METRIC [INCH]
CRITICAL DIMENSION
CHECKING IS COMPULSORY
VOLUME cm3
MASS grams REV. DATE MODIFICATIONS NAME ECN NO.
DENSITY g/cm3MATERIAL: Furrion Property Holding Ltd.
GENERAL TOLERANCES
EXCEPT AS NOTED
0 TO 6mm = ±0.1
>6 TO 30mm = ±0.2
>30 TO 80mm = ±0.3
>80 TO 180mm = ±0.4
>180mm = ±0.5
ANGULAR = ± 3°
FINISH SPEC:
COMPOSITE-NO SHEET 1 OF 1
SCALE: DATE: DRAWN BY: APPROVED BY: REVISION:
NAME: PART NO.
Program: Indesign CC
Black
User Manual for Furrion GWH IM-FHA00117
1.0
Karl Fung
Streng Shi XX
Streng Shi14-Apr-22
1.0 14-Apr-22 NEW
Printing Notes:
Material: 80 GSM Bond Paper or 50# Bond Paper White
Ink: Black
Resolution: 150 DPI or above
Printing method: Offset Printing
Binding: Saddle Stitch
Folded size: 210 x 285 mm (W x H)
DO NOT PRINT THIS PAGE
Tankless Water Heater
Chauffe-eau à Gaz Sans Réservoir
MODEL/MODÈLE: FGWH
USER MANUAL/MANUEL DUTILISATION
* Picture shown here is for reference only.
* L’image montrée ici est uniquement pour référence.
English
CCD-0005833 Rev: 04-14-22 - 1 -
Thank you for purchasing this Furrion® product. Before operating your new product, please read these instructions carefully.
This will ensure safe use and reduce the risk of injury. This instruction manual contains information for installation, operation,
maintenance of the product and safe use.
Please keep this instruction manual in a safe place for future reference. Be sure to pass on this manual to any new owners of this
product.
The manufacturer does not accept responsibility for any damages due to not observing these instructions.
Installer/Customer Responsibilities
Installation and Service must be performed by a Furrion recommended installer, service agency or gas supplier.
Do not attempt installation as a do-it-yourself project.
Read and observe all safety rules. Shut off gas appliances and their pilot lights (if any) when refueling.
Keep these instructions and warranty for future reference.
Follow all applicable State and Local Codes.
Follow a regular schedule of maintenance as outlined in this manual.
TABLE OF CONTENTS
EXPLANATION OF SYMBOLS..........................................................................................................................................................................
IMPORTANT SAFETY INSTRUCTIONS ........................................................................................................................................................
BEFORE INSTALLATION ....................................................................................................................................................................................
Select a Suitable Location ........................................................................................................................................................................................................................ 3
Site Preparation ..............................................................................................................................................................................................................................................3
WATER HEATER INSTALLATION ....................................................................................................................................................................
A: Installation of Water Heater with Separate Flange ...............................................................................................................................................................4
B: Installation of Water Heater with Integral Flange ...................................................................................................................................................................4
C: Installation of 12VDC Power and User Control Panel (UCP) ............................................................................................................................................5
D: Functional Tests ........................................................................................................................................................................................................................................ 5
E: Door Installation ........................................................................................................................................................................................................................................5
OPERATION ............................................................................................................................................................................................................
A: Understanding How the Furrion Tankless Water System Works ..................................................................................................................................6
B: Pressure Relief Valve ..............................................................................................................................................................................................................................7
C. Water Control Valve Flow Optimization (optional) ................................................................................................................................................................7
D: Operating Procedures ...........................................................................................................................................................................................................................7
E: Winter Use ....................................................................................................................................................................................................................................................8
TROUBLESHOOTING .........................................................................................................................................................................................
MAINTENANCE ......................................................................................................................................................................................................
Replacement Parts: ......................................................................................................................................................................................................................................9
Replacement Parts: Door Kit ...................................................................................................................................................................................................................10
SERVICE ...................................................................................................................................................................................................................
SPECIFICATIONS ..................................................................................................................................................................................................
WIRING DIAGRAM .................................................................................................................................................................................................
Functional Diagram of the Water Heater .......................................................................................................................................................................................... 12
Wiring Diagram of the Electrical Connections within the Unit .............................................................................................................................................12
Exploded view of all of Components .................................................................................................................................................................................................. 13
Control Module and its Connections ..................................................................................................................................................................................................13
English
CCD-0005833 Rev: 04-14-22
- 2 -
EXPLANATION OF SYMBOLS
This manual has safety information and instructions to help you
eliminate or reduce the risk of accidents and injuries. Always
respect all safety warnings identified with these symbols. A
signal word will identify safety messages and property damage
messages, and will indicate the degree or level of hazard
seriousness.
DANGER
Indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury.
WARNING
Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate personal injury, or
property damage.
IMPORTANT SAFETY INSTRUCTIONS
Read these instructions carefully to ensure safe and correct
operation of your appliance. Retain the instruction manual
and installation instructions for future use or for subsequent
owners.
WARNING
FIRE OR EXPLOSION
WARNING: These instructions must be followed exactly,
or a fire or explosion may result causing property damage,
personal injury or death. Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of this or any
other appliance.
FOR YOUR SAFETY - WHAT TO DO IF YOU SMELL GAS
DO NOT attempt to light any appliance.
DO NOT touch any electrical switch, or use any phone or
radio in the vehicle.
DO NOT start the vehicles engine or electric generator.
Evacuate all persons from the vehicle.
Shut off the gas supply at the gas container or source.
Contact the nearest certified service technician or gas
supplier for repairs.
If you cannot reach a certified service technician or gas
supplier, contact the nearest fire department.
DO NOT turn on the gas supply until the gas leak(s) has
been repaired.
Installation and Service must be performed by a Furrion
recommended installer, service agency or gas supplier.
WARNING
CRITICAL INSTALLATION WARNINGS
Installation and Service must be performed by a Furrion
recommended installer, service agency or gas supplier.
This product is not designed for Do-it-Yourself
Installation.
Install ONLY in recreational vehicles (RV’s). RV’s are
recreation vehicles designed as temporary living
quarters for use as recreation, camping, or travel having
their own power or towed by another vehicle. This water
heater is NOT designed for Marine or Space Heating
applications.
All combustion air must be supplied from the outside of
the RV, and all products of combustion must be vented to
the outside of the RV.
DO NOT vent water heater with a venting system serving
another appliance or to an outside enclosed porch area.
DO NOT modify water heater in any way. This is
dangerous and will void the warranty.
DO NOT alter water heater for a positive grounding
system.
DO NOT HI-POT water heater unless the electronic
ignition control (circuit board) has been turned ‘OFF’
(Power switch is in “Off” position)
DO NOT use battery charger to supply power to water
heater even when testing.
Protect building materials from flue gas exhaust.
Install the water heater on an exterior wall, with access
door opening to the outdoors.
DO NOT lift the water heater or carry it by holding the
exhaust tube.
English
CCD-0005833 Rev: 04-14-22 - 3 -
BEFORE INSTALLATION
This water heater is certified for installation in
Recreational Vehicles (RVs) and is not for use in Marine
or Space Heating Applications.
The installation must conform to one or more of the
following, as applicable:
1. Local codes or, in the absence of local codes, the National
Fuel Gas Code, ANSI Z223.1/NFPA 54 and/or CSA B149.1,
Natural Gas and Propane Installation Code.
2. Local codes or, in the absence of local codes, Recreational
Vehicles, NFPA 1192 and/or CAN/CSA-Z240 RV Series.
USA AND CANADA - FOLLOW ALL APPLICABLE STATE
AND LOCAL CODES
IN THE ABSENCE OF LOCAL CODES OR REGULATIONS
REFER TO CURRENT STANDARDS.
WARNING - CAUTION
Improper installation, adjustment, alteration, service or
maintenance can cause property damage, personal
injury or loss of life.
Installation and Service must be performed by a Furrion
recommended installer, service agency or gas supplier.
The following instructions apply to the most common type
of installation for Furrion F2GWH Water Heater. Consult
with Furrion Technical Support or Engineering department
if you have any additional questions regarding your specific
installation/application.
IMPORTANT!
For proper operation this water heater requires a minimum
water flow of .80 Gallon per Minute (gpm) for each Hot
Water faucet it supplies.
Select a Suitable Location
The water heater is designed to be installed on a floor or a
fixed platform with access to water, LP gas and a 12VDC
electrical connection from the back. It is recommended that
the F2GWH be located as near the center of the coach as
possible.
DO NOT INSTALL IN AN AREA WHERE ONE OR
BOTH THE INLET AIR VENT AND FLUE VENT CAN
BE COVERED BY A DOOR OR ACCESS PANEL WHEN
OPENED.
DO NOT INSTALL WHERE THE FLUE VENT IS CLOSER
THAN ONE FOOT IN ALL DIRECTIONS FROM ANY
WINDOW OR OPENING INTO THE VEHICLE.
DO NOT INSTALL THE WATER HEATER OR ANY OTHER
APPLIANCE WHERE IT CAN VENT INTO AN AREA
COVERED BY AN AWNING, CANOPY OR ANY OTHER
ENCLOSURE.
NOTE: The water heater can be installed under an RV roll-out/
retractable type awning providing the awning does not have an
enclosure such as a screen room and/or some type of “walled
enclosure”.
Site Preparation
To install on carpeted area you must install a metal or wood
panel under the water heater that extends at least 3 inches
beyond the width and depth of the unit. If water leakage can
result in damage to the adjacent area, install a drain pan that
can be drained to outside of the vehicle, under the water
heater.
Verify that a clearance of 1 inch will remain after installation
between the top surface of the water heater and any
combustible material. Zero inch clearance is acceptable for the
sides.
Make sure that the front edge of the opening is surrounded by
a solid frame to firmly anchor the water heater; if needed, build
an appropriate frame using 2" X 2" elements.
The rough opening for the F2GWH should be 13" X 13" with
right angle corners. The exterior wall opening must be the
same dimensions with no radius corners.
Ensure that electrical water and gas connections from the
vehicle are in place for installing the unit.
Allow sufficient length and flexibility in the electrical, water and
gas lines to reach the connections while the unit is partially
inserted into the opening.
English
CCD-0005833 Rev: 04-14-22
- 4 -
WATER HEATER INSTALLATION
1. Remove the water heater from the box by grasping the
metal sides of the housing and lifting upward until it is free
of the box.
2. Partially insert the water heater into the opening and
connect both Hot and Cold water lines to the appropriate
½" NPT fittings. Connections can be made using PEX
swivel nut adaptors with NPT straight threads and a cone
seal. The PEX swivel nuts require only hand tightening.
CAUTION
PRODUCT DAMAGE!
Excessive torque will damage the Cold Water and Hot
Water Inlets. DO NOT over tighten.
Use two wrenches to tighten the LP Gas compression
fitting to avoid damaging the unit.
3. Connect the gas to the ⅜" LP Gas compression fitting on
the back of the Water Heater (Figure 2).
4. Use two wrenches to tighten the compression fitting to
avoid damaging the unit.
5. Use additional caulking if needed to complete a permanent
seal at the gas line connection.
A: Installation of Water Heater with
Separate Flange
NOTE: For installation of water heater with Integral Flange
proceed to section B:
1. Complete the “skin” application to the vehicles outer wall.
2. Position water heater housing into the frame opening with
the front edge aligned evenly to the exterior wall.
3. To prevent water and air leaks apply sufficient caulking
around the entire frame opening and the exterior edge of
the water heater housing. Use a suitable caulking material
that will result in a permanent seal between the water
heater and the vehicles frame.
4. Insert the door flange into the water heater housing and
press the flange firmly against the sidewall.
5. When ready to proceed, apply additional caulking or butyl
tape to the back of the door flange that will contact the RV
sidewall around perimeter of the opening.
6. To ensure proper installation and alignment of the door:
Align each hole along the inside frame of the flange with
the corresponding holes in the water heater housing and
secure to the frame using No. 8¾" flat head screws using
two screws per side.
7. Secure the flange to the vehicle using No. 8¾" flat head
screws through each hole along the perimeter. Verify that a
tight seal exists between the side wall and the flange. If not,
repeat above steps.
8. Remove any excess caulking and clean all surfaces.
B: Installation of Water Heater with
Integral Flange
1. Protect the side wall with masking tape or other suitable
means to insure that it is not damaged while installing the
water heater.
2. Position the water heater so that the front edge extends
from the opening approximately 2” and insert the door
flange into the housing.
3. Permanently attach the flange to the housing by aligning
holes and using stainless steel screws or stainless steel
rivets with recommended grip range of .188" to .129" and
with a hole-size of .129" to .133".
4. To prevent water leaks apply a good amount of caulking or
butyl tape on the sidewall and bottom of the opening that
will be covered by the flange.
5. Slide the water heater in place into the opening and press
the door flange against the sidewall.
6. Secure water heater housing unit to the vehicle using No.
8¾" flat head screws through each hole in the door flange.
English
CCD-0005833 Rev: 04-14-22 - 5 -
Verify that a tight seal exists between the side wall and the
flange. If not, repeat above steps.
C: Installation of 12VDC Power and User
Control Panel (UCP)
1. SET THE WATER HEATER POWER SWITCH TO THE
“OFF” POSITION and connect the power supply wires
(on rear of water heater – Red & Black wire). Red wire to a
12VDC circuit from the DC panel protected with an interior
power switch (not provided) and a 10 amp fuse. Connect
Black wire to a ground connection on the panel.
NOTE - The Red wire is positive (+) and the Black wire is
negative (-).
2. Determine location for the User Control Panel (UCP –
Figure 5) inside the RV. Drill a ¾" hole and then run 2 – 18
gauge wires from the rear of water heater to the ¾" hole
(maximum wire length is 16’ or 5M). Connect the 2 wires to
the User Control Panel 2 wires and to the 2 wires on rear of
water heater (UCP wires are Blue or Blue/Green). Note –
UCP wires can be connected to either color/lead wire.
°C / °F
CAUTION - Do not connect UCP wires to the power wires
(BLACK or RED) on rear of water heater.
INSTALLATION NOTE – The micro processor is always on. It
draws approximately .20AMPs so it is advisable to turn OFF
the 12V power when in storage or dry camping. This can be
accomplished by installing or utilizing an interior power switch
(not provided) or turning the Water Heater circuit OFF.
WARNING
DO NOT use matches, candles or other sources of ignition
when checking for gas leaks.
D: Functional Tests
1. Verify the power switch on water heater is in the “OFF
position (located inside water heater compartment) or the
interior Water Heater Power Switch (if installed).
2. Turn on the water supply to the unit.
3. Open and then close the HOT & COLD water faucets in the
vehicle to fill the pipes with water. If needed, purge air out of
all water lines including washers, toilet and outside faucets.
Close the faucets when the water is flowing smoothly and
verify that there are no leaks at the connections and within
the water heater.
4. Confirm that there is a “steady” water flow (not pulsating). If
pulsating have the water pump settings adjusted.
5. Turn on the gas supply and check all gas connections
for leaks including exterior gas connection and gas
connection to the gas valve inside the Water Heater
compartment.
6. Turn the power switch to the “ON” position and verify the
UCP is illuminated (push RED power button on the UCP to
illuminate). It will show the Hot Water temperature setting.
7. The recommended and factory setting is 115°F or 46°C.
8. Open a Hot water faucet and verify that the unit ignites and
supplies hot water at the faucet.
9. The UCP display will show the following icons: fan, flame
and water temperature. See page Figure 5 for icon
identifications.
10. WHILE UNIT IS RUNNING, verify that there are no leaks
at the external gas connection and in proximity of the Gas
Control within the unit.
E: Door Installation
WARNING
It is necessary to use only an applicable F2GWH Furrion
Water Heater Door Kit with a Furrion F2GWH Water Heater.
Use of any other brand of water heater door will affect the
operation and performance of the Furrion Water Heater and
may cause a hazardous condition.
The door of the F2GWH water heater is hinged on the left side
of the mounting flange and swings open from the right. The
latch must secure the door closed at all time during operation.
English
CCD-0005833 Rev: 04-14-22
- 6 -
If necessary for service, the door can be removed by removing
hinge screws. Keep screws in a secure pace for remounting
the door. Optional - To further secure the door, you may add a
screw in the hole provided in the bottom.
To further secure the door, add a screw in the hole provided in
the bottom.
If necessary for service, the door can be removed by extracting
the pins that retain the hinges. Take care not to lose the pins to
replace the door when finished.
WARNING - CAUTION
The appliance and its individual shut-off valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of ½ psi.
The appliance and its gas connection must be leak
tested before placing the appliance in operation.
If an external electrical source is utilized, the appliance,
when installed, must be electrically grounded in
accordance with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70
and/or the CSA C22.1, Canadian Electrical Code.
This completes the installation instructions of the Model
F2GWH water heater.
OPERATION
WARNING
CONSUMER SAFETY WARNING!
Use with LP gas only.
Shut off all gas appliances and pilot lights when refueling.
Turn gas OFF at the LP tank when vehicle is in motion.
This disables all gas appliances and pilot lights. Gas
appliances must never be operated while vehicle is in
motion.
LP tanks must be filled by a qualified gas supplier only.
Should overheating occur, turn gas OFF at the LP tank
and turn the operating switch to the OFF position.
A: Understanding How the Furrion
Tankless Water System Works
In a conventional installation the Furrion Tankless Water Heater
is connected to:
1. The RV’s cold water system deriving its water input from
a pressurized (45 psi or greater) source such as a shore
connection or an RV water pump connected to the RV’s
fresh water storage tank.
NOTE - A steady water flow (no pulsating) will ensure a
consistent temperature and performance.
2. The RV’s hot water system (i.e. faucets and shower).
3. The RV’s LP Gas system capable of supplying its rated
BTU requirement. The Furrion model F2GWH introduces a
new generation of smart tankless water heater designed
specifically for Recreation Vehicles (RV). Its configuration
and size are consistent with the tank based RV water
heaters currently in use and is designed for OEM’s and
after- market use by the RV industry.
4. The RV’s 12VDC electrical power.
The Water Heater’s microprocessor based controller (Control
Module) receives from electronic sensors the data it needs to
decide each step of the Model F2GWH operation.
1. Display on the User Control Panel (UCP) each phase of
the Water Heater’s operation and receive from the user the
operation parameters desired:
ON/OFF to activate
Desired outlet temperature
2. Verify that all components are in working order and that it
is safe to start the unit upon sensing the minimum amount
of water flow required (.90 Ga/min)
3. Verify that the blower is operating and supplies the air flow
needed to maintain clean combustion.
4. Open the gas control and light the burner according to the
procedure required by the safety standard.
5. Adjust the gas flow to reach and maintain the desire
temperature set by the user
6. Continue operation as long as:
The water flow is above the minimum required
The presence of flame is verified
No unsafe condition develops
7. Provide the user with a visual indication of the operating
conditions turning on the appropriate icon and displaying
the current outlet temperature:
Fan icon on: Blower operating
Flame icon on: Burner is lit and flamed is detected
Shower Head on: Water is flowing
8. The button marked “C/F” determines if the temperature is
displayed in °F or °C degrees
9. Whenever the “UP” or “Down” are pressed the display
shows the set temperature.
10. If an unsafe condition is encountered and the unit shuts off,
the display will show an Error Code corresponding to the
actual condition that caused the unsafe condition.
See Troubleshooting section for a list of all error codes.
English
CCD-0005833 Rev: 04-14-22 - 7 -
B: Pressure Relief Valve
A new pressure-relief valve, complying with the standard for
relief valves and automatic shut-o ff devices for hot water
supply systems, ANSI Z21.22/C SA 4.4, must be installed at
the hot water outlet connection of the water heater during
installation. Local codes shall govern the installation of any
relief valve. The relief valve is not attached to the gas water
heater.
NOTICES:
The following drawing illustrates a pressure-only relief
valve. If local codes require a combination temperature and
pressure-relief valve, you may need to install an extension
piece to ensure that the valve probe is not directly in the
flow path of the water.
A pressure-rellief valve supplied with this water heater
must be installed as shown below.
Manual operation of the valve should be performed at least
once a year.
If the relief valve on the system discharges periodically, a
problem exists. Turn off the water heater, unplug the unit
and call for service.
One end of the relief valve discharge line connects to the
hot water outlet pipe as shown above. The other end of
the pipe should be routed to a suitable drain to eliminate
potential water damage.
C. Water Control Valve Flow
Optimization (optional)
The Water Control Valve of the F2GWH provides good control
of the outlet temperature within a wide range of inlet water
temperatures as are normally encountered in Recreational
Vehicles. The unit is shipped with the Water Control Valve set
at fully open/maximum flow. If desired, the operating flow can
be manually adjusted. It is located on the rear of the water
heater.
In case of operation with extreme cold inlet water temperatures
(approximately less than 45°(F) the performance of the Water
Control Valve can be optimized by adjusting the flow as shown
in Figure 8 below.
NOTE - This also can be accomplished by adjusting the hot
water flow at the faucet.
D: Operating Procedures
The Model F2GWH can be operated from the User Control
Panel which includes the Power ON/OFF switch.
°C / °F
The model F2GWH can be operated in two different
ways:
1. Operate like a Tank Water Heater. The user turns on the hot
water and add cold water to achieve the desired Hot water
temperature.
2. Select the desired temperature by adjusting temperature
setting up (^) or down (v). The UCP settings are from 95°
(F) to 124° (F). The unit will maintain the set temperature.
NOTE – The recommended and Factory setting is 115°F or
46°C.
For normal operation:
1. Turn on the power. The panel will light and will display the
current temperature at the inlet of the unit.
2. Press a temperature selection arrow (up or down) to see
English
CCD-0005833 Rev: 04-14-22
- 8 -
the current set temperature.
3. Adjust the set temperature to your preference.
4. Turn on the faucet.
WARNING
It is dangerous to operate a Tankless Water Heater
unattended. This may occur accidentally if a sufficient leak
develops in the water system or if a faucet is left open. For
this reason The F2GWH will automatically turn off after
operating for 20 minutes and displays Error “En” on the
Display.
E: Winter Use
Winterization
Freezing of the water heater and its plumbing components
will result in severe damage not covered by warranty. For
this reason it is advisable to follow the recommendations
below if the unit is to be stored in a freezing environment or
for long periods of time. At the start of the winter season or
before traveling to a location where freezing conditions are
likely, the unit must be winterized. The very small amount of
water present in the heat exchanger DOES NOT require the
installation of a bypass kit. Winterization can be accomplished
using one of the two common methods of winterization used
for RV water systems:
Compressed Air method: Drain all water from the system
opening one tap at a time and using compressed air to
purge all remaining water.
Anti-freeze method: Follow the recommendations of the
Recreational Vehicle manufacturer and fill the system with
a non-toxic anti-freeze. Make sure that the anti-freeze flows
from each tap to complete the process.
Antifreeze Device
If you wish to operate the water heater in potentially freezing
conditions the model F2GWH has a built in thermostat that
will start the burner whenever the temperature of the Heat
Exchanger falls below 38°F and will automatically shut off
when it senses a temperature in excess of 58°F.
IMPORTANT NOTICE
To allow the Antifreeze Device to operate you must have
sufficient LP Gas in the tank and 12VDC power available and
you must leave the unit powered with the ON / OFF switch
in the ON position at all times that freezing may occur. It will
not protect the entire RV’s plumbing system. The RV must be
designed for winter use/freezing conditions.
TROUBLESHOOTING
If a failure were to occur in the F2GWH it will be detected by
the Controller Module and the specific cause will be indicated
by the Error Code on the User Control Panel display.
E0: Water Outlet Temperature Probe failure.
An open circuit or short circuit condition is detected: This could
be due to an internal failure in the Temperature Probe or to a
faulty connection (Wires)
E1: Ignition failure or accidental flame off during ignition.
If the established flame signal is lost while the burner is
operating, the control will respond within 0.8 seconds, the
gas valve is de-energized and a new inter-purge and ignition
routine will begin. If the burner does not light, the control will
de-energize the gas valve and will make one more attempt to
relight the burner. If the burner does not relight after the two
trials the control will go into LOCKOUT and the unit will need
to be turned off before it can operate again. (Turn hot water
faucet OFF and back ON to re-set) This could occur for a
number of reasons.
The most common are:
Lack of Gas in the tank
Faulty Igniter
Faulty Igniter connections
Improper distance between the Igniter and the Burner
Accumulated dirt or obstruction between
Igniter and Burner
Low Gas Inlet pressure
E2: Flame sensing interrupted during normal operation.
Buzzer will sound.
Possible causes are the same as indicated by Error E1 if any of
these conditions occur during normal operation. A lock out will
occur also in these conditions.
E3: ECO open before ignition or during normal
operation.
This occurs if the ECO thermostat opens. Under normal
circumstances this is due to the Temperature of the water
at the Outlet exceeds 140˚ F (60°C). The cause must be
identified and removed before restarting the unit.
E4: Water Inlet Temperature Probe probe failure.
An open circuit or short circuit condition is detected: This could
be due to an internal failure in the Temperature Probe or to a
faulty connection (Wires)
E5: Blower motor failure.
No motor signal was detected before ignition or during normal
operation. This could be also caused by a wiring fault in the
motor connections.
E6: Over Temperature.
Outlet Water Temperature has exceeded 140°F (60°C) for 3
sec.
E7: Linear valve failure:
The Controller Module detects an open circuit in the Linear
Valve control circuit before ignition or during normal operation
indicating a faulty Valve.
English
CCD-0005833 Rev: 04-14-22 - 9 -
E8: Air pressure switch:
Air pressure switch not detected for 7 sec. before ignition or is
cut-off for 2 sec. during normal operation. This failure may be
caused by a faulty motor or a blockage in the air supply or in
the exhaust system.
E9: Flame sensor:
Flame is sensed before ignition. Buzzer will sound. This is
displayed when a short is detected in the flame sensor.
En: System Timer:
Water Heater ran longer than 20 min.
Fd: Water heater operating in Winter Use Mode (Freeze
Protection):
The unit will run for a few seconds and shut off. This will occur
when in freezing conditions if the LP gas and 12V power
are ON. This Mode will only protect the water heater Heat
Exchanger and not the RV’s plumbing system.
MAINTENANCE
CAUTION
Label all wires prior to disconnection when servicing
controls.
Wiring errors can cause improper and dangerous
operation.
Verify proper operation after servicing.
We recommend that the F2GWH water heater be inspected
monthly by the user and at least once a year by a Furrion
recommended service technician.
Before an inspection, make sure that the Electrical Power, LP
Gas and Water systems are turned on. Purge air out of ALL hot
and cold water lines. Verify that there are no combustible
materials, gasoline or other flammable vapors and
liquids in proximity of the unit.
A routine inspection must include the following items:
1. Inspect the integrity of the sealing (caulking or tape)
between the side wall and the door of the water heater and
ensure that the unit is solidly mounted to the vehicle.
2. Verify that the air inlet openings (louvers) are completely
open and clear of any debris including mud, leaves, twigs,
insects etc. Remove all obstructions to allow full air flow.
3. Insects, including mud wasps and spiders, can build
nests in the Exhaust Tube Outlet which will affect the
performance of the unit. Inspect the Flue Outlet Tube to
make sure that It is unobstructed and that the screen is
clean. If debris or insects are present, clean and vacuum
to remove any remaining debris. The use of any type of
aftermarket screen to cover the vent is not permitted and
will void the warranty.
4. Open the door and verify that no debris or extraneous
combustible materials are present anywhere (especially in
the area of the burner and the gas controls). Remove any
item present and wipe clean the bottom of the housing.
5. Inspect the interior surface of the housing for any cracks
or corroded areas that could allow penetration of gases
into or out of the interior of the vehicle. Check especially
around the Hot Water, Cold Water, Gas and electrical
connections.
6. There is a filter screen on the Water Heater inlet water line
connection, unscrew the water line connection from water
inlet and check the screen to ensure no debris.
7. Check that all wire connections are firmly in place and
there are no signs of chafing or cracks on the insulation.
Verify that the spark ignition cable between the Control
Board and the igniter is securely in place and not shorted
to any metal component.
8. Check relief valve to ensure it has not been leaking (no
water residue).
9. Turn ON the power to the water heater and open a hot
water faucet to inspect the flame of the burner. The flame
should be of the normal bluish appearance that indicates
proper combustion. This can be accomplished by opening
the water heater door and observing the flames by looking
at the burner under the edge of the heat exchanger.
10. If unit overheats (limits) often and the relief valve
discharges periodically contact your service center.
Replacement Parts:
#Description Photo Qty
1Shell Top 1
2Proportional Valve (Gas Valve) 1
3Valve Bracket 1
4Power switch & Fuse holder Assy 1
5Fuse Holder 10A 1
6Controller Bracket 1
7Air Pressure Switch 1
8Control Box (Microprocessor) 1
9User Control Panel (UPC) Remote Cont. 1
10 Water Pipe Screw Cover 1
English
CCD-0005833 Rev: 04-14-22
- 10 -
#Description Photo Qty
11 O-Ring 1
12 Inlet-Valve Gas Train 1
13 Valve-Burner Gas Train 1
14 Igniter 1
15 Burner 1
16 Shell Bottom 1
17 Pressure Relief Valve Direction Tube 1
18 Pressure Relief Valve 1
19 Pressure Relief Direction Connector 1
20 Rubber Gasket 1 1
21 Water Pipe Assembly 1
22 Flow Switch Inlet 1
23 Filter Screen Inlet 1
24 Dust Cap: Inlet/Outlet 1
25 Flow Switch Inlet Knob 1
26 Water Flow Sensor 1
27 Rubber Gasket 2 1
28 Temperature Probe for Water Inlet 1
29 Inlet Thermostat (Antifreeze) 1
30 Temperature Probe for Water Outlet 1
#Description Photo Qty
31 Heater Exchanger 1
32 (ECO) T-Switch 1
33 Strain Relief 1
34 Blow Motor Assembly 1
Replacement Parts: Door Kit
#Description Photo Qty
1F2GWHD Door Kit (White) New install/
Sub 6 gal 1
2F2GHWDB Door Kit (Black) New install/
Sub 6 gal 1
3F2GWDA6 Door Kit (White) Atwood 6 gal 1
4F2GWHDAS10 Door Kit (White) Sub/
Atwood 10 gal 1
5F2GWD Door Only (White) 1
6F2GWHDB Door Only (Black) 1
7F2GWHD Flange Only 1
8F2GWHDA6 Door Only (White) 1
9F2GWHDA6 Flange Only 1
10 F2GWHDAS10 Door Only (White) 1
11 F2GWHDAS10 Flange Only 1
12 Door Hinge 1
English
CCD-0005833 Rev: 04-14-22 - 11 -
#Description Photo Qty
13a Vent Silicone Ring (White) 1
13b Vent Silicone Ring (Black) 1
#Description Photo Qty
14a Door Latch Lock
(White) 1
14b Door Latch Lock
(Black) 1
15 Door Latch Spring 1
SERVICE
Your Furrion Tankless Water Heater is manufactured to the
highest standards and is designed to provide years of trouble
free use but in the event you require service please follow the
steps outlined below. Remember as an owner, you are required
to provide proof of purchase date through a Bill of Sale or other
appropriate record.
1. For warranty/service information contact a Furrion Water
Heater Service Center, call the Furrion Technical Support
Department at 1-800-789-3341 or visit our website at www.
furrion.com for a local recommended service center.
2. If the Furrion water heater was installed by the OEM it may
be under their warranty, follow the steps suggested by the
manufacturer of your RV or contact Furrion.
3. Call the service center, describe your problem and make
an appointment if necessary. SERVICE CALLS TO
CUSTOMER LOCATION ARE THE RESPONSIBILITY OF
THE OWNER.
4. FURRION WILL NOT PAY THE SERVICE CENTER FOR
WARRANTY REPAIRS WITHOUT PRIOR APPROVAL.
5. Provide the Service Center with purchase documentation
for your Furrion Water Heater.
The Furrion F2GWH Water Heater is designed for use in
recreation vehicles for the purpose of heating water as stated
in the “rating plate” attached to the water heater. Any other
use, unless authorized in writing by the Furrion Engineering
Department, voids the warranty.
SPECIFICATIONS
Specifications
BTU/HR 42,000 BTU
Fuel Propane (LP Gas)
Inlet Pressure 11” WCI Min to 14” WCI Max
Manifold Pressure 1.5” – 7.8” WCI
Power Input 12VDC < 3 amp
Water Operating Pressure 125 PSI Max
Dimensions Width: 12.5”, Height: 12.5”, Depth 15.5
Shipping Weight 22 lbs.
ECO Max Temperature 140° (F)
Altitude Table
Elevation 0 - 2000 ft. 2000 - 4000 ft.
Input 42,000 BTU 37,000 BTU
Manufacturers Recommended Orifice Size 0.82 mm 0.82 mm
Pression Multiple 1.5”-7.8”WCI Max 1.5”-7.8”WCI Max
Carburant Propane Propane
WIRING DIAGRAM
English
CCD-0005833 Rev: 04-14-22
- 12 -
Functional Diagram of the Water Heater
Wiring Diagram of the Electrical Connections within the Unit
Cutting
1 Blue
2 Blue
White
White
Blue
Blue
White
Red
Black
Brown
5 Yellow
4 Yellow
1 Red
3 Black
Inlet temp probe
Outlet temp probe
Remote controller
Water flow sensor
Wind pressure switch
Flame sensor/Red
Ignition pin
GND
To Switch On/Off
proportional valve
To Proportional
valve
To ECO thermostat
To Anti-freeze thermostat
1
Motor plug
1PIN: FG(Feedback)
2PIN: 0~+5VDC
3PIN: GND
4PIN: +24VDC
2 Black
1 Red
White
Black
2 Black
1 Red
Black
White
Orange
Yellow
Blue
Red
DC motor
WIRING DIAGRAM
Exploded view of all of Components
English
CCD-0005833 Rev: 04-14-22 - 13 -
Control Module and its Connections
Français
CCD-0005833 Rev: 04-14-22 - 14 -
Mercipour l'achat de ce produit Furrion®. Avant d’utiliser votre nouveau produit, veuillez lire attentivement les présentes consignes.
Cela garantit une utilisation en toute sécurité et réduit tout risque de blessures. Ce manuel d'instructions contient des informations
pour l'installation, l'utilisation, l'entretien du produit et son utilisation en toute sécurité.
Veuillez conserver le présent manuel d’instructions en lieu sûr afin de pouvoir vous y référer ultérieurement. Assurez-vous de
transmettre ce manuel à tout nouveau propriétaire de ce produit.
Le fabricant décline toute responsabilité en cas de dommages liés au non-respect de ces instructions.
Responsabilités Installer / clients
L’installation et l’entretien doivent être effectués par un installateur recommandé par Furrion, une agence de service ou un
fournisseur de gaz.
Ne tentez pas de l’installation comme un projet “Do-it-Yourself.”
Lire et respecter toutes les règles de sécurité.
Arrêter les appareils à gaz et leurs veilleuses (le cas échéant) lors du ravitaillement.
Conservez ces instructions et la garantie pour référence future.
Suivez tous les codes d’État et locales applicables.
Suivez un programme régulier d’entretien, comme indiqué dans ce manuel.
TABLE DES MATIÈRES
EXPLICATION DES SYMBOLES ......................................................................................................................................................................
CONSIGNES DE SÉCURITÉ IMPORTANTES .............................................................................................................................................
AVANT L’INSTALLATION ....................................................................................................................................................................................
Choisissez un endroit approprié............................................................................................................................................................................................................16
Préparation de l’emplacement ...............................................................................................................................................................................................................16
INSTALLATION DU CHAUFFEEAU ...............................................................................................................................................................
A: Installation de chauffe-eau avec bride séparée ......................................................................................................................................................................17
B: L’installation de chauffe-eau avec bride separée ..................................................................................................................................................................17
C: Installation de 12VDC, et le panneau du contrôle de l’utilisateur (UCP) ....................................................................................................................18
D: Les tests fonctionnels ............................................................................................................................................................................................................................18
E: Door Installation ........................................................................................................................................................................................................................................19
FONCTIONNEMENT ............................................................................................................................................................................................
A: Comprendre le fonctionnement du système Furrion du chauffe-eau sans réservoir sur demande .........................................................19
B: Soupape de décharge de pression ................................................................................................................................................................................................20
C. Loptimisation de la vanne de contrôle du flux d’eau (optionnel) ................................................................................................................................... 20
D: Procédures de Fonctionnement ...................................................................................................................................................................................................... 21
E: L’utilisation en hiver .................................................................................................................................................................................................................................21
DÉPANNAGE ...........................................................................................................................................................................................................
ENTRETIEN .............................................................................................................................................................................................................
Pieces de replacement ............................................................................................................................................................................................................................... 23
Replacement Parts: Door Kit ...................................................................................................................................................................................................................24
SERVICE ...................................................................................................................................................................................................................
CARACTÉRISTIQUES ..........................................................................................................................................................................................
SCHÉMA DE CÂBLAGE ......................................................................................................................................................................................
Un Diagramme Fonctionnel du Chauffe-Eau .................................................................................................................................................................................26
Un diagramme des câblages des connexions électriques à l’intérieur de l’unité ...................................................................................................... 26
Une vue éclatée de l’ensemble des composants ........................................................................................................................................................................27
Une image de la module de contrôle et de ses connexions ..................................................................................................................................................27
Français
CCD-0005833 Rev: 04-14-22
- 15 -
EXPLICATION DES SYMBOLES
Le présent manuel contient des consignes de sécurité et des
instructions visant à vous aider à éliminer ou à réduire tout
risque d’accidents et de blessures. Respectez toujours tous
les avertissements de sécurité identifiés par ces symboles. Un
terme de mise en garde identifiera des messages de sécurité
ainsi que des messages signalant des risques de dommages
matériels et indique le degré ou le niveau de gravité du danger.
DANGER
Indique une situation de danger immédiat qui, si elle n’est pas
évitée, provoque des blessures graves, voire la mort.
AVERTISSEMENT
Indique une situation de danger potentiel qui, si elle nest pas
évitée, peut provoquer des blessures graves, voire la mort.
ATTENTION
Indique une situation de danger potentiel qui, si elle nest pas
évitée, peut provoquer des blessures corporelles mineures
ou modérées ou des dommages matériels.
CONSIGNES DECURITÉ IMPORTANTES
Lisez attentivement ces instructions afin d'assurer un
fonctionnement adéquat et sécuritaire de l’appareil. Conservez
le manuel d'instructions et les instructions d'installation pour
une utilisation ultérieure ou pour les futurs propriétaires.
AVERTISSEMENT
INCENDIE PU EXPLOSION
ATTENTION: Ces instructions doivent être suivies à la lettre,
un incendie ou une explosion entraînant des dommages
matériels, des blessures ou la mort. Ne pas entreposer
ou utiliser d’essence ou d’autres vapeurs et liquides
inflammables à proximité de cet ou tout autre appareil.
POUR VOTRE SÉCURITÉ --- QUE FAIRE SI UNE ODEUR
DE GAZ
NE PAS tenter d’allumer l’appareil.
Ne touchez aucun interrupteur électrique, ou utilisez un
téléphone ou la radio dans le véhicule.
NE PAS démarrer le véhicule de moteur ou générateur
électrique.
Évacuez toutes les personnes du véhicule.
Coupez l’alimentation en gaz à la bouteille de gaz ou la
source.
Contactez un technicien de service certifié le plus
proche ou le fournisseur de gaz pour les réparations.
Si vous ne pouvez pas parvenir à un technicien de
service ou fournisseur de gaz certifié, contactez le
service d’incendie le plus proche.
NE PAS brancher le gaz jusqu’à ce que la fuite (s) de gaz
a été réparé.
L’installation et l’entretien doivent être effectués par un
installateur recommandé Furrion, une agence de service
ou fournisseur de gaz.
AVERTISSEMENT
AVERTISSEMENTS CRITIQUES D’INSTALLATION
Installation et maintenance doivent être effectuées par
un installateur recommandé par Fur, une agence de
service ou un fournisseur de gaz.
Ce produit na pas été conçu pour installation ‘Do-it-
Yourself’. Installer uniquement dans les véhicule récréatif
(VR). VR sont des les véhicule récréatif conçus comme
des logements temporaires pour une utilisation comme
les loisirs, le camping, ou Voyage ayant leur propre
pouvoir ou remorqué par un autre véhicule. Ce chauffe-
eau est PAS conçu pour les applications marines ou le
chauffage.
Tout l’air de combustion doit être fournie de l’extérieur du
camping-car, et tous les produits de combustion doit être
évacué à l’extérieur du camping-car.
NE PAS ventiler chauffe-eau avec un système de
ventilation desservant un autre appareil ou à un extérieur
de la zone de véranda.
NE PAS modifier le chauffe-eau en aucune façon. Ceci
est dangereux et annule la garantie.
NE PAS modifier chauffe-eau pour un système de mise à
la terre positive.
NE PAS HI-POT chauffe-eau sans la commande
d’allumage électronique (circuit de bord) a été tourné
“OFF” (interrupteur d’alimentation est en position “Off”)
NE PAS utiliser le chargeur de batterie pour alimenter le
chauffe-eau, même lors de l’essai.
Protéger les matériaux de construction de
l’échappement des gaz de combustion. Installez le
chauffe-eau sur un mur extérieur, avec porte d’accès
d’ouverture vers l’extérieur.
NE PAS soulever le chauffe-eau ou transporter en le
tenant par le tuyau
Français
CCD-0005833 Rev: 04-14-22 - 16 -
AVANT L’INSTALLATION
Ce chauffe-eau est certifié pour l’installation dans les
véhicule récréatif (VR) (RV), et non pour une utilisation
dans marins ou Espace.
L’installation doit être conforme à l’une ou plusieurs des
mesures suivantes, selon le cas:
1. Les codes locaux ou, en l’absence de codes locaux, le
National Fuel Gas Code, ANSI Z223.1 / NFPA 54 et /
ou CSA B149.1, Gas Natural et le Code d’installation du
propane.
2. Les codes locaux ou, en l’absence de codes locaux,
véhicules récréatifs, NFPA 1192 et / ou CAN / CSA-Z240
VR Series.
USA ET CANADA - Prendre State CODES ET LOCALES
APPLICABLES EN LABSENCE DE
CODES ou réglementations locales se référer aux
normes EN COURS.
AVERTISSEMENT -
ATTENTION
Une installation, un réglage, une modification, un service
ou d’entretien peut causer des dommages matériels, des
blessures ou des pertes de vie.
L’installation et l’entretien doivent être effectués par un
installateur recommandé de Furrion, une agence de
service ou un fournisseur de gaz
Les instructions suivantes concernent le type le plus commun
de l’installation pour le F2GWH chauffe-eau. Consultez Furrion
soutien ou de l’ingénierie département technique si vous avez
des questions supplémentaires concernant votre installation /
application spécifique.
IMPORTANT!
Pour un bon fonctionnement de ce chauffe-eau nécessite
un fluxe d’eau minimum de .80 gallon par minute (gpm) pour
chaque robinet d’eau chaude qu’il alimente
Choisissez un endroit approprié
Le chauffe-eau est conçu pour être installé sur un plancher
ou une plate-forme fixe avec accès à l’eau, le gaz et une
connexion électrique 12VDC de l’arrière. Il est recommandé
que le F2GWH soit situé aussi près du centre du vehicule que
possible.
NE PAS L’INSTALLER DANS UN ENDROIT OÙ LA PRISE
DAIR OU L’ÉVENT D’ÉVACUATION PEUVENT ÊTRE
RECOUVERTS LORSQU’UNE PORTE OU UN PANNEAU
DACCÈS DU VÉHICULE EST OUVERT.
NE PAS INSTALLER DANS UN ENDROIT OÙ L’ÉVENT
D’ÉVACUATION SE TROUVE À MOINS 30 CM, DANS
TOUTES LES DIRECTIONS, D’UNE FENÊTRE OU D’UNE
OUVERTURE DU VÉHICULE.
NE PAS INSTALLER LE CHAUFFE-EAU OU TOUT AUTRE
APPAREIL DANS UN ENDROIT OÙ L’ÉVACUATION SE
FERAIT DANS UN ESPACE FERMÉ PAR UN AUVENT, UN
DAIS OU DE TOUT AUTRE FAÇON.
NOTE: Le chauffe-eau peut être installé sous un VR roll-out /
rétractable de type auvent fournir le store n’a pas une enceinte
comme une salle de l’écran et / ou un certain type de “enceinte
fortifiée”.
Préparation de l’emplacement
Pour une installation sur une surface recouverte de tapis, il faut
placer un panneau de métal ou de bois sous le chauffe-eau,
plus large et plus profond d’au moins 3 7,6 cm de chaque côté
de l’appareil. Si une fuite d’eau peut causer des dommages
à l’aire environnante, installer, sous le chauffe-eau, un bac
d’égouttage permettant l’évacuation vers l’extérieur du
véhicule.
S’assurer qu’après l’installation, il restera un espace de 2,5 cm
entre le dessus du chauffe-eau et tout matériau combustible. Il
est acceptable de ne pas avoir d’espace sur les côtés.
S’assurer que le rebord avant de l’ouverture est entouré
d’un cadre solide pour bien ancrer le chauffeeau; au besoin,
construire un cadre approprié à l’aide de planches 2 x 2.
Plate-forme fixe
et sol du VR
DO NOT RESTRICT AIR FLOW
13”
13”
Louverture inachevée pour le modèle GSWH-1 doit mesurer
33,4 cm x33,4 cm avec des angles droits. Louverture du mur
extérieur doit avoir les mêmes dimensions sans coins arrondis.
Vérifiez que les connexions d’eau et de gaz électriques du
véhicule sont en place pour l’installation de l’unité.
Prévoyez une longueur et une flexibilité suffisante dans
les lignes d’eau et de gaz électriques pour atteindre les
connexions alors que l’appareil est partiellement inséré dans
l’ouverture.
Français
CCD-0005833 Rev: 04-14-22
- 17 -
INSTALLATION DU CHAUFFEEAU
1. Retirer l’élément chauffant de la boîte à eau en le saisissant
par les côtés métalliques du boîtier et soulever vers le haut
jusqu’à ce qu’il soit libre de la boîte.
2. Insérez partiellement le chauffe-eau dans l’ouverture et
connecter à la fois chaud et les lignes d’eau froide aux ½
“NPT appropriées. Les connexions peuvent être faites en
utilisant des adaptateurs PEX pivotant de noix avec des fils
droites du TNP et un joint de cône. Les écrous tournants
PEX ne nécessitent qu’un serrage à la main.
ATTENTION
DOMMAGES AU PRODUIT
Un serrage excessif endommagera les raccordements
d’arrivée d’eau froide et d’eau chaude. NE PAS trop
serrer.
Utilisez deux clés pour serrer la compression de gaz de
LP montage pour éviter d’endommager l’appareil.
3. Branchez le gaz à la «LP Gas raccord de compression de
3/8 à l’arrière du chauffe-eau.
4. Utilisez deux clés pour serrer le raccord pour éviter
d’endommager l’unité de compression.
5. Utiliser du calfeutrage supplémentaire si nécessaire pour
compléter un joint permanent au niveau du raccordement
de la conduite de gaz.
A: Installation de chauffe-eau avec bride
séparée
NOTE: Pour l’installation de chauffe-eau avec bride solidaire
aller à la section B:
1. Remplir la demande de “peau” de la paroi extérieure du
véhicule.
2. Placez le chauffe-eau boîtier dans l’ouverture du cadre
avec le bord avant alignés pour le mur extérieur.
Appliquer le calfeutrage
des deux côtés
3. Pour éviter les fuites d’eau et d’air appliquent calfeutrage
suffisant autour de l’ouverture de l’ensemble de cadre
et le bord extérieur du boîtier du chauffe-eau. Utilisation
d’un matériau de calfeutrage approprié qui se traduira par
un joint permanent entre le chauffe-eau et le châssis du
véhicule.
4. Insérez la bride de la porte dans le boîtier de chauffe-eau
et appuyez sur la bride fermement contre la paroi latérale.
5. Lorsque vous êtes prêt à procéder, appliquez du
calfeutrage supplémentaire ou ruban de caoutchouc
butyle à l’arrière de la bride de la porte qui sera en
contact de la paroi latérale de VR autour du périmètre de
l’ouverture.
6. Alignez chaque trou le long du cadre intérieur de la bride
avec les trous correspondants dans le boîtier du chauffe-
eau et sécurisé à l’image à l’aide n ° 8 - ¾ “vis à tête plate à
l’aide de deux vis de chaque cô.
7. Fixer la bride sur le véhicule en utilisant n ° 8 - ¾ “vis à tête
plate dans chaque trou le long du périmètre. Vérifiez que
un joint étanche existe entre la paroi latérale et le rebord.
Sinon, répétez les étapes ci-dessus.
8. Retirer touts excès de calfeutrage et nettoyer toutes les
surfaces.
B: L’installation de chauffe-eau avec
bride separée
1. Protéger la paroi latérale avec du ruban adhésif ou
d’autres moyens appropriés pour assurer qu’il ne soit pas
endommagé lors de l’installation du chauffe-eau.
2. Placez le chauffe-eau de sorte que le bord avant étend
depuis l’ouverture d’environ 2 “et insérez la bride de la porte
dans le boîtier.
3. Fixer en permanence la bride sur le boîtier à l’aide de vis en
acier inoxydable ou des rivets en acier inoxydable avec la
gamme du emprise de .188 “à .129” et avec un trou de taille
de .129 “à .133”.
4. Pour prévenir les fuites d’eau appliquent une bonne
quantité de calfeutrage ou de la bande de butyle sur le
flanc et le bas de l’ouverture qui sera couvert par la bride.
5. Faites glisser le chauffe-eau en place dans l’ouverture et
appuyez sur le rebord de la porte contre la paroi latérale.
Français
CCD-0005833 Rev: 04-14-22 - 18 -
6. sécurisé unité de logement du chauffe-eau pour le véhicule
en utilisant n° 8 - ¾ “vis à tête fraisée à travers chaque trou
dans le rebord de porte (Figure 4 et Figure 7). Vérifiez que
un joint étanche existe entre la paroi latérale et le rebord.
Sinon, répétez les étapes ci-dessus.
Appliquer le
calfeutrage le long
de chaque côté
C: Installation de 12VDC, et le panneau
du contrôle de l’utilisateur (UCP)
1. FIXEZ LE COMMUTATEUR ELECTRIQUE DU CHAUFFE-
EAU ELECTRIQUE EN POSITION «OFF» et branchez les
fils d’alimentation électrique (à l’arrière du chauffe-eau - fils
Rouge et Noir). Le fil Rouge à un circuit 12VDC à partir du
panneau DC protégé par un commutateur d’alimentation
intérieur (non fourni) et un fusible de 10 ampères.
Connectez le fil Noir à une connexion de masse sur le
panneau. NOTE - Le fil Rouge est positif (+) et le fil Noir est
négatif (-).
2. Déterminez l’emplacement du Panneau de Contrôle de
l’Utilisateur à l’intérieur du VR. Percez un trou de ¾ “et
exécutez 2-18 fils de calibre de l’arrière du chauffe-eau
au trou de ¾” (longueur de câble maximale est de 16 ‘ou
5M). Connectez les 2 bleu fils au Panneau de Contrôle
de l’Utilisateur 2 fils et aux 2 fils à arrière de chauffe-eau.
Remarque – les fils UCP peuvent être connectés à couleur
/ câble principale.
°C / °F
ATTENTION - Ne pas connecter les fils UCP aux fils
d’alimentation (NOIR ou ROUGE) à l’arrière du chauffe-eau.
NOTE D’INSTALLATION – Le micro processeur est toujours
allumé. Puisqu’il attire environ 0,20 SAP, il est conseillé de
couper l’alimentation de 12 V en cas de stockage ou ou
camping autonome. Ceci peut être accompli en installant ou en
utilisant un interrupteur intérieur (non fourni) ou en désactivant
le circuit du Chauffe-Eau.
AVERTISSEMENT
NE PAS utiliser d’allumettes, de bougies ou toute autre
source d’allumage pour vérifier laprésence éventuelle de
fuites de gaz.
D: Les tests fonctionnels
1. Vérifiez que le commutateur d’alimentation sur le chauffe-
eau est en position «OFF» (situé dans le compartiment de
chauffe-eau) ou le commutateur intérieur électrique du
chauffe-eau (si installé).
2. Ouvrez l’approvisionnement en eau vers l’unité.
3. Ouvrez puis fermez les robinets de l’eau FROIDE et
CHAUDE dans le véhicule pour remplir les tuyaux avec de
l’eau. Si nécessaire, évacuez l’air de toutes les conduites
d’eau y compris les rondelles, toilettes et robinets
extérieurs. Fermez les robinets quand l’eau coule librement
et vérifiez qu’il ny a pas de fuites au niveau des raccords et
à l’intérieur du chauffe-eau.
4. Vérifiez qu’il ya un flux d’eau “constant” (pas de pulsation).
En cas de pulsation, réglez les paramètres de la pompe
d’eau.
5. Ouvrez l’alimentation en gaz et vérifiez toutes les conduits
de gaz contre fuites de gaz, y compris le conduit extérieure
et le conduit de gaz à la vanne de gaz à l’intérieur du
compartiment du chauffe-eau.
6. Tournez l’interrupteur d’alimentation sur la position “ON”
et vérifiez que l’UCP est allumé (appuyez sur le bouton
d’alimentation ROUGE sur le UCP pour allumer). Il affichera
le réglage de la température d’Eau Chaude.
7. Le réglage d’usine recommandé est de 115 degrés (F) ou
46 degrés (C).
8. Ouvrez un robinet d’eau Chaude et vérifiez que l’unité
sallume et fournit de l’eau chaude au robinet.
9. Laffichage UCP indiquera les icônes suivantes: ventilateur,
flamme et de la température d’eau. Voir le panneau de
configuration pour les identifications d’icônes.
10. LORS DU FONCTIONNEMENT DE L’UNITE, vérifiez qu’il
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33

Furrion F2GWH Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues