PTM / PTM-B
Page 2 Installation Instructions
Contact Premier Mounts with any questions:
(800) 368-9700
Contents
Warning Statements
Weight Limit
Maximum Flat Panel Weight: 50 lbs.
THE WALL STRUCTURE MUST BE CAPABLE OF SUPPORTING AT
LEAST FOUR TIMES THE WEIGHT OF THE FLAT PANEL. IF NOT,
THE WALL STRUCTURE MUST BE REINFORCED.
PRIOR TO THE INSTALLATION OF THIS PRODUCT, THE INSTALLATION INSTRUCTIONS MUST BE READ AND
COMPLETELY UNDERSTOOD. KEEP THESE INSTALLATION INSTRUCTIONS IN AN EASILY ACCESSIBLE LOCATION
FOR FUTURE REFERENCE.
PROPER INSTALLATION PROCEDURE BY A QUALIFIED SERVICE TECHNICIAN MUST BE FOLLOWED, AS OUTLINED
IN THESE INSTALLATION INSTRUCTIONS. FAILURE TO DO SO COULD RESULT IN PROPERTY DAMAGE, SERIOUS
PERSONAL INJURY, OR EVEN DEATH.
SAFETY MEASURES MUST BE PRACTICED AT ALL TIMES DURING THE ASSEMBLY OF THIS PRODUCT. USE PROPER
SAFETY EQUIPMENT AND TOOLS FOR THE ASSEMBLY PROCEDURE TO PREVENT PERSONAL INJURY.
PREMIER MOUNTS DOES NOT WARRANT AGAINST DAMAGE CAUSED BY THE USE OF ANY PREMIER MOUNTS
PRODUCT FOR PURPOSES OTHER THAN THOSE FOR WHICH IT WAS DESIGNED OR DAMAGE CAUSED BY
UNAUTHORIZED ATTACHMENTS OR MODIFICATIONS, AND IS NOT RESPONSIBLE FOR ANY DAMAGES, CLAIMS,
DEMANDS, SUITS, ACTIONS OR CAUSES OF ACTION OF WHATEVER KIND RESULTING FROM, ARISING OUT OF OR
IN ANY MANNER RELATING TO ANY SUCH USE, ATTACHMENTS OR MODIFICATIONS.
If mounting to wall studs or ceiling studs, make sure that the mounting screws are anchored into the center of the wall studs or
It is recommended that a maximum of ⅝″ plaster board be used when mounting to wooden studs.
Be aware of the mounting environment. If drilling and/or cutting into the mounting surface, always make sure that there
are no electrical wires in wall. Cutting or drilling into an electrical line may cause serious personal injury.
Make sure there are no water or natural gas lines inside the wall where the mount is to be located. Cutting or drilling into a
water or gas line may cause severe property damage or personal injury.
This product is intended for indoor use only. Use of this product outdoors could lead to product failure and/or serious personal
injury.
Do not install near sources of high heat. Do not install on a structure that is prone to vibration, movement or chance of impact.
Weight Limit. ............................................................................................................................................................. 2
Warning Statements. ................................................................................................................................................ 2
Installation Tools. ...................................................................................................................................................... 3
Parts List................................................................................................................................................................... 4
Mounting Hardware. ................................................................................................................................................. 4
Features. .................................................................................................................................................................. 4
Installing the Wall Plate. ........................................................................................................................................... 5
Determining the Mounting Surface. ............................................................................................................. 5
Wood Stud Installation. ................................................................................................................................ 5
Concrete Installation. ................................................................................................................................... 6
Mounting Hardware. ................................................................................................................................................. 8
Selecting the Mounting Hardware. .............................................................................................................. 8
Universal Spacer Installation. ...................................................................................................................... 9
UFP-280 Adapter Plate Installation. ............................................................................................................ 9
Attaching the Flat Panel to the Mount. ................................................................................................................... 10
Attaching the Mount to the Wall Plate. ................................................................................................................... 10
Securing the Mount. ............................................................................................................................................... 11
Adjusting the Mount Tension. ................................................................................................................................. 11
Removing the Mount. ................................................................................................................................ 11
Adjusting the Tension. ............................................................................................................................... 11
Replacing the Mount. ................................................................................................................................. 11
........................................................................................................................................ 12
Warranty. ................................................................................................................................................................ 13
PTM / PTM-B
Installation Instructions Page 3
Installation Tools
by Premier Mounts, but you can purchase them at your local hardware store.
Pencil Level
1/8” Wood
Drill Bit
Electronic Stud Finder Socket Wrench
Phillips Tip
Screwdriver
Tape Measure
Hand Held Drill
Hammer**
5/16” Concrete
Drill Bit**
Protective Eyewear
1/2″ Socket
** Optional tools for concrete / steel stud installations.
AVANT L’INSTALLATION DE CE PRODUIT, LES CONSIGNES D’INSTALLATION DOIVENT ÊTRE LUES ET PLEINEMENT COMPRISES.
CONSERVER CES CONSIGNES D’INSTALLATION DANS UN ENDROIT FACILEMENT ACCESSIBLE POUR RÉFÉRENCE FUTURE.
LA PROCÉDURE D’INSTALLATION CORRECTE PAR UN TECHNICIEN QUALIFIÉ DOIT ÊTRE OBSERVÉE, COMME DÉCRIT DANS CES
CONSIGNES D’INSTALLATION. FAUTE DE QUOI DES DOMMAGES MATÉRIELS, BLESSURES GRAVES, VOIRE MÊME LA MORT PEUT
SUBVENIR.
DES MESURES DE SÉCURITÉ DOIVENT ÊTRE PRATIQUÉES À TOUT MOMENT DURANT L’ASSEMBLAGE DE CE PRODUIT. UTILISER
L’ÉQUIPEMENT ET OUTILS DE SÉCURITÉ APPROPRIÉ POUR LA PROCÉDURE D’ASSEMBLAGE AFIN D’ÉVITER DES BLESSURES.
LES SUPPORTS PREMIER MOUNTS NE GARANTISSENT PAS CONTRE LES DOMMAGES CAUSÉS PAR L’USAGE DU PRODUIT DE
MONTAGE PREMIER MOUNTS À D’AUTRES FINS QUE CELLES POUR LESQUELLES IL A ÉTÉ CONÇU OU DES DOMMAGES CAUSÉS
PAR DES ACCESSOIRES OU DES MODIFICATIONS NON AUTORISÉS, ET NOUS NE POUVONS PAS ÊTRE TENUS RESPONSABLES
DES DOMMAGES, PLAINTES, RÉCLAMATIONS, POURSUITES, ACTIONS OU CAUSES D’ACTION DE N’IMPORTE QUELLE MANIÈRE
RÉSULTANT DE, DÉCOULANT DE OU TOUCHANT DE N’IMPORTE QUELLE MANIÈRE UN TEL USAGE, ACCESSOIRE OU MODIFICATION
Au moins deux pe s
matériels dû à la chute ou à la manipulation incorrecte de l’écran plat.
Si le montage s’effectue sur des rivets, assurez-vous que les vis de montage sont ancrées au centre des rivets. L’usage d’un détecteur de rivet
bord-à-bord est recommandé.
Il est recommandé qu’un maximum de plaque-plâtre de ⅝″ soit utilisé lors d’un montage sur des rivets à bois.
Familiarisez-vous avec l’environnement de montage. Si un perçage et/ou une coupe est opéré sur la surface de montage, assurez-vous toujours
S’assurer qu’il n’y a pas de canalisation d’eau à l’intérieur du mur où le montage doit être localisé. Une coupe/perçage dans une canalisation
d’eau peut causer sérieusement endommager le circuit d’eau au niveau de la surface de montage.
Ce produit n’est destiné qu’à être utilisé à l’intérieur. L’utilisation de ce produit à l’extérieur pourrait entraîner des défauts matériels et/ou des
blessures graves.
Ne pas installer près de sources de forte chaleur. Ne pas installer sur une structure soumise aux vibrations, aux mouvements ou aux chocs.
AVERTISSEMENT
PTM / PTM-B
Page 4 Installation Instructions
Features
Versatile Mounting Points
mount, in concert with the
UFP-280, provides mounting points
for 75mm x 75mm VESA and 100mm
x 100mm VESA, as well as 200mm x
100mm and 200mm x 200mm mount
Robust Mount Design
it.
Dynamic Viewing
360° rotation and 15° of tilt
allow for excellent viewing
Adjustable Tension
Stays where you want it
or weight.
Stylish Design
Sleek and unobtrusive, yet
supremely sturdy.
Less than 3” from the wall.
Smooth Function
Exclusive Radial Glide Technology™
Universal Spacers
Premier Mounts uniquely
multiple screw sizes, and
work with either the PTM
mount or the UFP-280
Adapter Plate.
PTM Tilt/Pivot Mount Components/ Hardware
Tilt/Pivot MountWall Plate UFP-280
Adapter Plate
#14 x 2”
Wood Screws
M3 Allen Wrench 5/16” Concrete
Wedge Anchors
14mm Socket
Universal Spacers
M4 Flat Washers M5 Flat Washers
x1 x1 x1 x4 x4 x1
x1
x1
x4 x30 x4 x6
M4 x 10mm
x6
M4 x 16mm
x6
M4 x 20mm
x6
M4 x 30mm
M4 x 45mm M6 x 10mm M6 x 16mm M6 x 20mm M6 x 30mm M6 x 45mm
M8 x 20mm
x6 x4 x4 x4 x4 x4 x4
M5 x 10mm
M5 x 16mm M5 x 20mm M5 x 30mm M5 x 45mm M4 x 5mm M4 x 10mm
x4
x4 x4 x4 x4 x4 x4
Parts List
Your Premier Mounts product is shipped with all proper installation hardware and components. Make sure that
none of these parts are missing and/or damaged before beginning installation. If there are parts missing and/or
damaged, please stop the installation and contact Premier Mounts (800) 368-9700.
PTM / PTM-B
Installation Instructions Page 5
Installing the Wall Plate
If you will be installing your PTM mount to wood studs, proceed to the “Wood Stud Installation” section.
If you will be installing your PTM mount to a concrete wall, proceed to the “Concrete Installation” section.
Determining the Mounting Surface
Wood
Stud
Concrete
Wood Stud Installation
Step 1
Step 2
You must secure the wall plate to the wall stud with all four (4) #14 x 2″ wood
screws.
wall plate.
Use a pencil to mark the exact center of the wall stud where you will be installing
your PTM mount.
Place the wall plate against the wall in the desired viewing location.
Adjust the wall plate to align the mounting points in the wall plate with the
center of the wall stud.
Level the wall plate.
Use a pencil to mark all four (4) mount locations along the center of the wall
stud.
X
X
Vous devez assembler la sablière sur le rivet à bois avec tous les quatre (4) vis à
bois de #14 x 2″.
Minimum of 2 by 4 wood stud to be used
Minimum de 2 par 4 bois goujon pour être utilisé
PTM / PTM-B
Page 6 Installation Instructions
Step 4
Place the wall plate against the wall and align it with the holes.
Insert one (1) #14 x 2″ wood screw into each of the mounting holes and
tighten using a Phillips screwdriver.
Do not overtighten the wood screws.
Proceed to the “Mounting Hardware” section.
The supplied 5/16″ concrete wedge anchors must be used for concrete
installation.
You will need a 5/16″ concrete drill bit, which is available at your closest
hardware store.
Concrete Installation
Concrete Wedge Anchors
Example of 5/16Concrete Drill Bit (Not Included)
Installing the Wall Plate (cont’d)
Step 3
Drill four (4) holes in the center of each of the marks using a power drill and a ⅛˝
drill bit.
Only use a ⅛˝ drill bit when drilling the holes.
X
X
N’utiliser qu’un foret de ⅛˝ lors du forage des trous.
Éviter de trop serrer les vis à bois.
Les ancres de cale en béton de 5/16˝ fournies doivent être utilisées pour
l’installation du béton.
PTM / PTM-B
Installation Instructions Page 7
Installing the Wall Plate (cont’d)
Place the wall plate against the wall in the desired viewing location.
Level the wall plate.
Use a pencil and mark all four (4) mounting locations where you will be
drilling holes for the concrete wedge anchors.
Set the wall plate to one side in a safe location.
Step 1
Use a power drill and 5/16″ concrete drill bit to drill a hole at each of the marks.
Step 2
Step 3
Insert a concrete wedge anchor into each hole.
If necessary, lightly tap each concrete wedge anchor into place with a
hammer.
Remove the nuts and washers from all four (4) concrete wedge anchors.
PTM / PTM-B
Page 8 Installation Instructions
Step 4
Installing the Wall Plate (cont’d)
Place the wall plate against the wall over the threaded shafts of the concrete
wedge anchors.
Attach the nuts and washers to each of the concrete wedge anchors and
tighten using a socket wrench and ½″ socket.
Do not overtighten the wedge anchor nuts.
Proceed to the “Mounting Hardware” section.
Mounting Hardware
Selecting the Mounting Hardware
Insert a small straw or toothpick into the threaded inserts found on the back
Use a pencil to mark the depth of the threaded insert on the small straw or
toothpick.
Mark the straw or toothpick 1/8” above the depth of the threaded insert, as
shown in Figure 1.
Insert the small straw or toothpick into the remaining threaded inserts to
compare and verify their depth using the straw or toothpick’s 1/8” allowance
mark.
Locate the correct diameter screw for the threaded insert.
If the screw you selected is longer than the 1/8” allowance mark on the small
straw or toothpick, as shown in Figure 2 and Figure 3, do not use this screw.
The screw length must not bypass the mark.
Test each size of the screws provided.
The correct screws should thread easily into the mounting point and not pull
out when tension is applied.
Recessed mounting points?
Uneven mounting points?
A curved back?
Any obstruction near the mounting point?
If Yes, you must install Universal Spacers. Proceed to the “Universal Spacer
Installation” section.
If No, skip to the “UFP-280 Adapter Plate Installation” section.
Small Straw or Toothpick
Small Straw
or Toothpick Small Straw
or Toothpick
Marking the 1/8”
Allowance
Depth Plus 1/8” Allowance
Mark
Depth Plus 1/8” Allowance
Mark
Éviter de trop serrer les écrous de l’ancre de cale.
Si la vis que vous sélectionnez est plus longue que la marque du jeu maximal
de 1/8” sur le paillon ou le cure-dents, comme illustré sur le schéma 2 et le
schéma 3, veuillez ne pas utiliser cette vis. La longueur de la vis doit dévier
la marque.
Votre écran plat est-il muni de :
Points de montage encastrés ?
Points de montage inégaux ?
Un plan arrière arrondi ?
Une obstruction à l’emplacement du point d’assemblage ?
ISi Oui, il vous faut installer des entretoises tous usages. Aller à la section
« Installation d’entretoise tous usages ».
Si Non, aller directement à la section
« Installation de la plaque d’adaptateur UFP-280 ».
PTM / PTM-B
Installation Instructions Page 9
Mounting Hardware (contd)
Universal Spacer Installation
Premier Mounts’ Universal Spacers allow you to attach the mounting bracket
The Universal Spacers must be stacked and oriented as shown.
The Universal Spacers must only be installed between the Adapter Plate and
75mm x 75mm VESA mounting points or 100mm x 100mm VESA
mounting points?
Proceed to the “Attaching the Flat Panel to the Mount” section.
100mm x 200mm mounting points or 200mm x 200mm mounting
points?
Proceed to the “UFP-280 Adapter Plate Installation” section.
UFP-280 Adapter Plate Installation
and 200mm x 200mm mounting points to the PTM mount.
Determine which mounting points will be used.
Refer to the section for UFP-280 Adapter Plate
mounting points.
Secure the UFP-280 Adapter Plate to the back of the monitor using the
following hardware:
If you are using the 200mm X 100mm mounting points, you must use the M4
If you are using the 200mm x 200mm mounting points...
...and you selected M4 screws from the “Selecting the Mounting
Hardware”
...and you selected M5 screws from the “Selecting the Mounting
Hardware”
Proceed to the “Attaching the Flat Panel to the Mount” section.
Les entretoises tous usages doivent être empilées et orientées comme illustré.
Les entretoises tous usages ne doivent être installées qu’entre la plaque
d’adaptateur et votre écran plat.
Votre écran plat est-il muni de :
Points d’assemblage VESA de 75 mm x 75 mm VESA ou points d’assemblage
VESA de 100 mm x 100 mm ?
Aller à la section «Fixation de l’écran plat sur le support » .
Points d’assemblage de 100 mm x 200 mm ou points d’assemblage de 200 mm
x 200 mm ?
Aller à la section « Installation de la plaque de l’adaptateur UFP-280 ».
PTM / PTM-B
Page 10 Installation Instructions
u
u
Attaching the Flat Panel to the Mount
Attaching the Mount to the Wall Plate
not tighten the screws at this time.
If you are using the UFP-280 Adapter Plate, you can use either of the A or B mounting points. Refer to the section for UFP-280
Adapter Plate mounting points.
Insert the heads of the M4 x 5mm Phillips screws through the keyhole slots.
Insert two (2) M4 x 5mm Phillips screws into the bottom mounting points.
Tighten all M4 x 5mm Phillips screws.
Do not overtighten the mounting hardware.
Proceed to the “Attaching the Mount to the Wall Plate” section.
Flat Panel without UFP-280 Adapter Plate Flat Panel with UFP-280 Adapter Plate
Flat Panel without UFP-280 Adapter Plate Flat Panel with UFP-280 Adapter Plate
Your PTM mount must be attached to the back plate that is secured to the wall. The back of your PTM
mount has a built-in bracket designed to “hang” on the wall plate.
Lift your PTM mount up to the wall plate.
Slide the top of the PTM mount on to the top of the wall bracket.
Pivot the bottom of the PTM mount towards the wall plate until it rests against the wall.
Do not release the PTM mount until you are certain that it is resting securely on the wall plate.
Proceed to the “Securing the PTM Mount” section.
Wall Plate
PTM Mount
Éviter de trop serrer le dispositif de montage.
Éviter de relâcher le support PTM jusqu’à ce que vous vous assuriez qu’il est
bien posé sur la sablière.
PTM / PTM-B
Installation Instructions Page 11
Securing the Mount
Adjusting the Mount Tension
Use the M3 Allen wrench to tighten the M6 x 35mm set screw located in the
from being accidently dislodged.
Do not overtighten the set screw.
Proceed to the “Adjusting the Mount Tension” section.
Use the M3 Allen wrench to loosen the M6 x 35mm set screw at the bottom of the PTM mount.
Gently lift, then gently pull the PTM mount away from the wall until it disengages from the wall plate.
Remove the two (2) M4 x 5mm Phillips screws from the bottom mounting points.
Loosen the two (2) M4 x 5mm Phillips screws from the top mounting points. Do not completely remove
these screws.
disengages from the keyhole slots.
Use a socket wrench and the supplied 14mm socket to loosen or tighten the tension nut.
Turn the tension nut clockwise to increase tension.
Turn the tension nut counter- clockwise to decrease tension.
Do not overtighten the tension nut.
Tension Nut
Set Screw
M3 Allen Wrench
Replace PTM mount by guiding the heads of the top two (2) M4 x 5mm Phillips screws through the keyhole slots.
Insert two (2) M4 x 5mm Phillips screws into the bottom mounting points.
Tighten all M4 x 5mm Phillips screws.
Do not overtighten the M4 x 5mm Phillips screws.
Lift your PTM mount up to the wall plate.
Slide the top of the PTM mount on to the top of the wall bracket.
Pivot the bottom of the PTM mount towards the wall plate until it rests against the wall.
Do not release the PTM mount until you are certain that it is resting securely on the wall plate.
Use the M3 Allen wrench to tighten the M6 x 35mm set screw located in the bottom of the PTM mount.
Do not overtighten the set screw.
Removing the Mount
Adjusting the Tension
Replacing the Mount
Éviter de trop serrer la vis de réglage.
Éviter de trop serrer l’écrou de tension.
Éviter de trop serrer les vis cruciformes de M4 x 5 mm.
Éviter de relâcher le support PTM jusqu’à ce que vous vous assuriez qu’il est
bien posé sur la sablière.
Éviter de trop serrer la vis de réglage.
PTM / PTM-B
Page 12 Installation Instructions
All measurements are in inches [millimeters].
A: 75mm x 75mm VESA mounting points.
B: 100mm x 100mm VESA mounting points.
C: 200mm x 100mm mounting points.
D: 200mm x 200mm mounting points.
(If M4 screws are used, M5 washers must be used as well)
PTM / PTM-B
Installation Instructions Page 13
PREMIER MOUNTS
LIMITED LIFETIME WARRANTY
What and Who is Covered by this Limited Warranty and for How Long
Premier Mounts warrants this product to be free from defects in material and workmanship for the lifetime of
What Premier Mounts Will Do
At the sole option of Premier Mounts, Premier Mounts will repair or replace any product or product part that is
defective. If Premier Mounts chooses to replace a defective product or part, a replacement product or part will
be shipped to you at no charge, but you must pay any labor costs.
What is Not Covered; Limitations
PREMIER MOUNTS DISCLAIMS ANY LIABILITY FOR DAMAGE TO MOUNTS, ADAPTERS, DISPLAYS,
PROJECTORS, OTHER PROPERTY, OR PERSONAL INJURY RESULTING, IN WHOLE OR IN PART, FROM
IMPROPER INSTALLATION, MODIFICATION, USE OR MISUSE OF ITS PRODUCTS.
PREMIER MOUNTS DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WAR-
RANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. PREMIER MOUNTS
IS NOT RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT
LIMITED TO, INABILITY TO USE ITS PRODUCTS OR LABOR COSTS FOR REMOVING AND REPLAC-
ING DEFECTIVE PRODUCTS OR PARTS. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMI-
TATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLU-
SION MAY NOT APPLY TO YOU.
What Customers Must Do for Limited Warranty Service
If you discover a problem that you think may be covered by the warranty you MUST REPORT it in writing to the
address below within thirty (30) days. Proof of purchase (an original sales receipt) from the original consumer
purchaser must accompany all warranty claims. Warranty claims must also include a description of the problem,
the purchaser’s name, address, and telephone number. General inquiries can be addressed to Premier Mounts
Customer Service at 1-800-368-9700. Warranty claims will not be accepted over the phone or by fax.
How State Law Applies
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.
Warranty
Disclaimer
Premier Mounts intends to make this manual accurate and complete. However, Premier Mounts makes no claim that the information contained herein
covers all details, conditions or variations, nor does it provide for every possible contingency in connection with the installation or use of this product.
The information contained in this document is subject to change without notice or obligation of any kind. Premier Mounts makes no representation of
warranty, expressed or implied, regarding the information contained herein. Premier Mounts assumes no responsibility for accuracy, completeness or
.
PREMIER MOUNTS
ATTN: Warrenty Claims
500 W Central Ave, Suite A
Brea, CA 92821
premiermounts.com | p. 800.368.9700 | e. [email protected]
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13

Premier Mounts PTM-B Mode d'emploi

Catégorie
Supports de bureau à panneau plat
Taper
Mode d'emploi

dans d''autres langues