Vari-Lite VLZ SPOT Guide de démarrage rapide

Catégorie
Stroboscopes
Taper
Guide de démarrage rapide
1
Introduction
About This Guide
This Quickstart Guide is intended for a knowledgeable user to unpack, install, and use the VLZ SPOT Luminaire in a short time period.
For the complete manual in PDF format, please visit our web site at: www.vari-lite.com and click the user manual download link on the
product downloads page. The complete manual provides you all information related to accessories, menu structures, DMX channel
mapping/ modes, and care for your new luminaire.
Read this manual in its entirety before operating luminaire. Keep this guide for future reference.
WARNING: It is important to read ALL accompanying safety and installation instructions to avoid damage to the product and potential
injury to yourself or others. AVERTISSEMENT: Il est important de lire toutes les instructions de sécurité et d'installation
d'accompagnement pour éviter d'endommager le produit et les risques de blessures à vous-même ou les autres.
Notes:
For complete product description, features, and specifications, refer to product specification sheet on the Vari-Lite
web site at www.vari-lite.com.
For power requirements, refer to Current vs. Voltage” on page 8.
VLZ SPOT Luminaires accept glass gobos only. Use of metal gobos will void the luminaire’s warranty.
Additional Documentation
For more information on installing DMX512 control systems, the following publication is available for purchase from the United States
Institute for Theatre Technology (USITT), "Recommended Practice for DMX512: A Guide for Users and Installers, 2nd edition"
(ISBN: 9780955703522). USITT Contact Information:
USITT
315 South Crouse Avenue, Suite 200
Syracuse, New York 13210-1844 USA
Phone: 800-938-7488 or +1-315-463-6463
Fax: 866-398-7488 or +1-315-463-6525
Web Site: www.usitt.org
Customer Service
Our Goal
At Vari-Lite, we are committed to providing you the highest quality in customer service. Our comprehensive resources are available to
help your business succeed and ensure you get the full benefit of being a Vari-Lite customer. Whether your needs are telephone
troubleshooting assistance, product training or technical service, our full-time staff of experienced professionals are on-hand to provide
support.
How to Reach Us
For assistance in your area, call the dealer from which your product was purchased.
or Contact an Authorized Service Center
or Contact the Vari-Lite Customer Service Department, 7am - 6pm CST Monday through Friday, at the following:
phone:1-877-VARI-LITE (1-877-827-4548) or +1-214-647-7880
e-mail: entertainment.service@philips.com
Note: Performing maintenance procedures may void the product warranty. Refer to the Vari-Lite Limited Warranty card included in the
product shipping package for more information. For all service and maintenance issues, please contact your local Authorized
VARI*LITE Dealer or Service Center.
Additional Resources
For additional resources and documentation on this product, please visit our website at www.vari-lite.com and follow the Support link.
Document Number: 02.9708.0001 Version as of: 10 January 2017
VL6000 Beam Luminaire QuickStart Guide
©2016 Vari-Lite. All rights reserved. 2
3
Compliance & Safety Notices
Compliance
This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when this equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with Vari-Lite system, service, and safety guidelines, may cause harmful interference to radio communications.
As tested under this standard:
FCC 47CFR 15B clA*CEI
Issued:2009/10/01 Title 47 CFR Part 15 Subpart B Unintentional Radiators Class A
Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to
correct the interference at his/her own expense.
EC Declaration of Conformity
We, Vari-Lite B.V., 10911 Petal Street, Dallas, Texas 75238, declare under our responsibility for the products contained herein are in
conformity with the essential requirements of the following European Directives and harmonized standards: Low Voltage
Director (LVD), 2006/95/EC EN 60589-2-17:1984+A1:1987+A2:1990 used in conjunction with 60598-1:2008/A11:2009
Electromagnetic Compatibility Directive (EMC), 2004//108/EC EN 55022:2010, EN55024:2010
Safety Notice
It is extremely important to read ALL safety information and instructions provided in this manual and any accompanying documentation before
installing and operating the products described herein. Heed all cautions and warnings during installation and use of this product. Safety symbols
used throughout this manual are as follows:
CAUTION advising of potential damage to product.
WARNING advising of potential injury or death to persons.
GENERAL INFORMATION PERTAINING TO PROTECTION AGAINST ELECTRICAL SHOCK, FIRE, EXPOSURE TO EXCESSIVE UV
RADIATION, AND INJURY TO PERSONS CAN BE FOUND BELOW.
WARNING: INSTRUCTIONS FOR CONTINUED PROTECTION AGAINST FIRE
1 Luminaires may be mounted on any type of surface as long as mounting instructions are followed. See instructions detailed in this manual.
2 Note distance requirement from combustible materials or illuminated objects for VARILITE luminaires.
WARNING: INSTRUCTIONS FOR CONTINUED PROTECTION AGAINST ELECTRICAL SHOCK
1 VARILITE luminaires are designed for dry locations only. Exposure to rain or moisture may damage luminaire.
2 Disconnect power before servicing any VARILITE equipment.
3 Servicing to be performed by qualified personnel only.
WARNING: INSTRUCTIONS FOR CONTINUED PROTECTION AGAINST EXCESSIVE
EXPOSURE TO UV RADIATION
1 It is hazardous to operate luminaires without lens or shield. Shields, lenses, or ultraviolet screens shall be changed if they have become
visibly damaged to such an extent that their effectiveness is impaired. For example, by cracks or deep scratches. Replace any cracked or
protective shields.
FCC
4
WARNING: INSTRUCTIONS FOR PROTECTION AGAINST INJURY TO PERSONS
1 Exterior surfaces of the luminaire will be hot during operation. Use appropriate safety equipment (gloves, eye protection, etc.) when handling
and adjusting hot equipment and components.
WARNING: RF INTERFERENCE
This is a Class A product. In a domestic environment this product may cause radio interference, in which case, the user may be required to take
adequate measures.
Notes de sécurité
Avant de procéder à l’installation des produits décrits dans ce guide et de les mettre en marche, il est extrêmement important de lire TOUS les
renseignements et TOUTES les directives de sécurité contenues dans ce guide ainsi que toute documentation jointe. Tenir compte de tous les
avertissements et suivre toutes les précautions pendant l’installation et l’utilisation de cet appareil. Les symboles de sécurité utilisés dans ce guide sont
les suivants :
ATTENTION Ce symbole annonce que l’appareil risque d’être endommagé.
AVERTISSEMENT Ce symbole annonce qu’il y a risque d’accident grave ou même fatal.
CETTE SECTION CONTIENT DES INFORMATIONS GÉNÉRALES POUR SE PROTÉGER CONTRE LES DÉCHARGES
ÉLECTRIQUES , LES INCENDIES, L’EXPOSITION EXCESSIVE AUX RAYONS UV ET TOUT AUTRE ACCIDENT POUVANT
ENTRAÎNER DES BLESSURES.
AVERTISSEMENT: DIRECTIVES POUR SE PROTÉGER CONTRE LES INCENDIES
1 Les luminaires peuvent être fixés sur tout type de surface tant que les directives de montage sont respectées. Voir les explications détaillées
dans ce guide.
2 Vérifier la distance à respecter entre les matériaux combustibles ou les objets illuminés et les luminaires VARILITE.
AVERTISSEMENT: DIRECTIVES POUR SE PROTÉGER CONTRE LES DÉCHARGES
ÉLECTRIQUES
1 Débrancher l’appareil avant de procéder à la révision de tout matériel VARILITE.
2 Les révisions doivent être effectuées uniquement par des personnes qualifiées.
AVERTISSEMENT: DIRECTIVES POUR SE PROTÉGER CONTRE UNE EXPOSITION
EXCESSIVE AUX RAYONS UV
1 L’utilisation des luminaires sans lentille ou blindage pose des risques. Tous blindages, lentilles ou écrans ultraviolet visiblement endommagés
au point que leur efficacité en est affectée doivent être remplacés, par exemple s’il y a des fissures ou de profondes rayures.
AVERTISSEMENT: DIRECTIVES POUR SE PROTÉGER CONTRE LES ACCIDENTS POUVANT
ENTRAÎNER DES BLESSURES
1 Les surfaces externes du luminaire deviennent brûlantes quand l’appareil est en marche. Pour manœuvrer ou ajuster des appareils brûlants et
leurs composants, se protéger suffisamment (gants, protection pour les yeux, etc.).
AVERTISSEMENT:
5
INTERFÉRENCE RF
Cet appareil est de Classe A. Dans un environnement domestique, cet appareil peut causer des interférences radio, et si c’est le cas,
l’utilisateur peut avoir à prendre des mesures adéquates.
Other
Battery Information / Informations sur la batterie
This unit has a battery. Warning: Caution risk of explosion if battery is replaced by an
incorrect type. Dispose of used batteries according to the instructions.
Cet appareil dispose d'une batterie. Avertissement: Attention risque d'explosion si la batterie
de remplacement par un type incorrect. Jetez les piles usageesselon les instructions.
6
About The VLZ SPOT Luminaire Included Items
Included Items
The following illustration shows all items included with the luminaire:
Figure 1: VLZ SPOT Luminaire Included Items
Note: * Please Check with the local Vari-Lite Office or Authorized Vari*Lite dealer for availability on accessories.
QuickStart Guide(this document)
Neutrik® powerCON® True1
AC Input Connector
7
Connecting Power and Data
Connecting Power
The luminaire requires standard AC power distribution from AC120-240V~, 50/60Hz. Current required depends on the AC supply
voltage and product model. Refer to “Current vs. Voltage” on page 8 for all models covered in this manual.
Note: The mating Neutrik® powerCON® True1 connector is supplied; however, you will need to purchase or construct a cable
appropriate for your application.
Figure 2: Power Connector
Depending on the application, the luminaire’s AC input cable may require a different connector. If required, install a new connector
meeting your requirements using the following wire color code reference:
Wire*
Connection
Green
AC Ground
White
AC Neutral
Blcak
AC Line
* International (Harmonized) Standard
WARNING: DO NOT connect to three-phase service in countries with 240 volt power. AVERTISSEMENT: NE PAS se connecter au
service en trois phases dans les pays avec puissance de 240 volts.
8
For single-phase power at 240 volts RMS:
Pin
X
Y
G
For three-phase power at 208 volts RMS:
Pin
X
Y
G
WARNING: It is not recommended to power any VARILITE luminaire from a dimmer - even in 'NONDIM' mode. Dimmer and
non-dim modules are not suitable sources of power because their output modifies the AC wave form. This may work for a short time,
but will eventually result in power problems, luminaire mis-operation and/or failure and may void the luminaire’s warranty.
AVERTISSEMENT: Il n'est pas recommandé pour alimenter un luminaire VARILITE d'un gradateur - même en mode 'NONDIM.
Modules de gradation et non sombres ne sont pas des sources appropriées de pouvoir parce que leur production modifie la forme d'onde
AC. Cela peut fonctionner pendant une courte période, mais finira par entraîner des problèmes d'alimentation, luminaires mauvais
fonctionnement et / ou l'échec et peut annuler la garantie de l'appareil.
Current vs. Voltage
AC Power Operation
When connected to an AC source, the unit operates on 100 to 240 volts AC (+/- 10%, auto-ranging). The luminaire contains an auto-ranging power
supply.Each luminaire can draw up to 850 Watts.
WARNING: It is the responsibility of the user to adequately protect supply source with a correct size and type circuit breaker and not
overload circuits. AVERTISSEMENT: Il est de la responsibilité de l'utilisateur de protéger adéquatement la source d'alimentation
avec une taille correcte et le disjoncteur de type et surchargez pas les circuits.
Connecting Data
A maximum of 32 luminaires may be connected in any one DMX data link.
Note: This maximum limit applies to the luminaire "daisy chain" only. Your system or console may require fewer luminaires on a
single data link path. Consult your console documentation for more information.
To connect power and data:
Step 1. Connect data cable from console to first luminaire in chain at DATA IN connector.
Step 2. If required, connect additional data cables from DATA THRU connectors to DATA IN connectors of remaining luminaires in link.
Step 3. At last luminaire in link, install male termination connector at DATA THRU connector. (Luminaires and other devices on the same DMX
chain may not function properly without termination.)
9
Figure 3: Data Link
Step 4. Connect AC Input Cable connector to power input source.
Step 5. Dress AC input and data cables and secure them so that they will not interfere with luminaire head and yoke movement.
10
Installation Procedures
Floor Mounting the Luminaire
All luminaires included in this manual are designed to sit directly on its base in a floor installation application. When used in this type of
application, be sure to leave enough space around the luminaire to allow proper, uninterrupted airflow for cooling and movement.
Hanging the Luminaire
The VLZ SPOT Luminaire can be hung horizontally or vertically from any structure designed to work with the type of load created by this
moving luminaire. Two mounting truss hooks or other mounting hardware are required. Many compatible truss hooks are available from different
manufacturers for your particular needs. A minimum of two hooks per luminaire is required. If mounting method does not use truss hooks, two
attachment points, per luminaire, are required.
Install mounting hardware and brackets:
Step 1. Install truss hooks on two provided truss hook brackets as required as shown in Figure 4.
Step 2. Determine required configuration of bracket installation. Brackets may be installed in
many different orientations as shown in Figure 5.
Step 3. While pulling up on locking mechanism release, fit keyed holes onto raised mounting buttons at
bottom of enclosure. Slide forward and release locking mechanism to lock in place. Ensure brackets are
locked securely.
WARNING: Ensure that the bracket locking mechanism is fully seated after the bracket is
installed on the luminaire. AVERTISSEMENT: Assurez-vous que le mécanisme de support
de verrouillage est complètement inséré après le support est installé sur l'appareil.
11
Figure 5: Installing Brackets on Luminaire Enclosure
12
Menu Operation
LCD Display and Menu System
The VLZ SPOT Luminaire’s LCD Display and Menu System provides local control for accessing the following fixture’s settings:
Address to set the DMX address
Configure various parameter settings
Fixture fixture status, recalibrate, reboot, software version, view fixtures hours, etc.
DMX change the map mode, invert pan/tilt check DMX real time data.
Manual manual control of parameters
Test test functions of parameters
The menu system is controlled at the Menu Display available at the enclosure input panel. If there are multiple luminaires in a system,
any settings or changes would need to be made at each LCD Menu as desired.
Menu Controls
The menu system is controlled by an MODE/ESC, , and four Arrow ( ) buttons. These buttons function are
shown in Figure 6.
Figure 6: Menu Controls
LCD Display and Menu System Operation
The LCD Display Menu system consists of several categories. Use the Menu Buttons to access and make changes to the menu items.
When the desired menu item is reached, press the desired Menu Button to display the menu options and to navigate and configure the
menu options as required.
To navigate and access menu settings/selections:
Step 1. Make sure unit is powered and turned on.
Step 2. Press [MODE/ESC] to access menu categories.
13
Step 3. Use four Arrow ( ) buttons to navigate through the various options and settings.
Step 4. Once menu item is reached, press OK [Enter] to access the menu item parameters.
Step 5. Make changes to parameters as desired.
Step 6. Press button to accept changes.
Other LCD Display Features
LCD Menu Battery Operation
The LCD menu system utilizes a battery powered system for operation when the luminaire is not connected to power. The primary
purpose of this mode is to allow basic setup and configuration of the luminaire.
To enable the battery operation of the menu system:
Step 1. Press [Mode] three seconds to activate display!
Step 2. Once enabled, the menu will function as normal with only the following sub-menu sections active:
Address
Configure
DMX
Fixture
Note: Any commands that require full power (calibrate, etc.) will be ignored while the menu system is in battery operation mode.
Step 3. To exit battery mode, press [MODE/ESC] three seconds.
Status Bar
The Status Bar (as illustrated in Figure 7) is present at all times and displays
luminaire operational information of the luminaire. The Status Bar contains the
following information:
LED - indicates current lamp state - ON or OFF.
ERRORS Displays a number indicating the total amount of current errors. When
errors are present, messages will appear in Red text. When no errors are present, NO
will display.
SHDN indicates hibernate mode YES or NO
MODEindicate fixture power modeSTA- Standard ModeSTE-- Studio Mode
MAP Displays the current DMX map mode setting. 16E--16-bit Enh Mode;1616 bit Mode
ADDR Displays the current DMX address for the fixture. NOTE, when the fixture does not detect a DMX input signal, the
DMX address text will display in Red text.
Figure 7: LCD display Status Bar
14
Quick Reference DMX Map
DMX
Channel
Parameter
Range DMX
Defaults
Description
Intensity
0-65535
0
16-bit control of Fixture Intensity from 0 - 100%
1
High Byte
2
Low Byte
Pan
0 - 65535
32767
16-bit linear control of pan from 0°-540°.
3
High Byte
With Expanded Movement turned on, 630° of pan is possible
4
Low Byte
Tilt
0 - 65535
32767
16-bit linear control of tilt from 0°-270°.
5
High Byte
6
Low Byte
Edge
0 - 65535
32767
16-bit linear control of edge functions
7
High Byte
8
Low Byte
Zoom
0 - 65535
32767
16-bit linear control of fixture zoom range between
9
High Byte
0 (narrow) to 65535 (wide).
10
Low Byte
11
Programming
0 - 255
0
Used as a control channel for different programmable settings.
Control
Set value of desired effect.
0 - 2
Idle
3 - 5
Linear Dimming Curve
6 - 10
Square Law Dimming Curve
11 - 15
TV Dimming Curve
16 - 20
Architectural Dimming Curve
51 - 55
Edge Track ON
56 - 60
Edge Track ON
61 - 65
Edge Track ON
66 - 70
Edge Track OFF
Cyan
0 - 65535
0
16 Bit control of cyan color mechanism.
12
High Byte
13
Low Byte
Yellow
0 - 65535
0
16 Bit control of yellow color mechanism.
14
High Byte
15
Low Byte
Magenta
0 - 65535
0
16 Bit control of Magenta color mechanism.
16
High Byte
17
Low Byte
CTO
0 - 65535
0
16 Bit contol of CTO mechanism.
18
High Byte
19
Low Byte
15
20
Color Wheel
0 - 255
0
8-bit linear control of Color Wheel 1. See Channel 16 for
options.
1
0 - 16
1. Open
17 -33
2. (Open/Color 1)
34 - 50
3. (Color 1)
51 - 67
4. (Color 1/Color 2)
68 - 84
5. (Color 2)
85 - 101
6. (Color 2/Color 3)
102 - 118
7. (Color 3)
119 - 135
8. (Color 3/Color 4)
136 - 152
9. (Color 4)
153 - 169
10. (Color 4/Color 5)
170 - 186
11. (Color 5)
187 - 203
12. (Color 5/Color 6)
204 - 220
13. (Color 6)
221 - 237
14. (Color 6/Open)
238 - 255
15. (Open)
DMX
Channel
Parameter
Range DMX
Defaults
Description
21
Color Wheel
1
0 - 255
0
Used as a control channel for different movement options of
Color
Control
Wheel 1.
0 - 5
Linear Movement using shortest (quickest) path.
6 - 10
Linear Movement using normal (longest) path.
11 - 15
Wheel Spin Forward (Fast to Slow)
16 - 20
Wheel Spin STOP
21 - 25
Wheel Spin Reverse (Slow to Fast)
26 - 56
Color Shake Quickest Path (Slow to Fast)
57 - 87
Color Shake Normal Path (Slow to Fast)
88 - 255
Reserved Values
22
Color Wheel
0 - 255
0
8-bit linear control of Color Wheel 1. See Channel 16 for
options.
2
0 - 16
1. Open
17 -33
2. (Open/Color 1)
34 - 50
3. (Color 1)
51 - 67
4. (Color 1/Color 2)
68 - 84
5. (Color 2)
85 - 101
6. (Color 2/Color 3)
102 - 118
7. (Color 3)
16
119 - 135
8. (Color 3/Color 4)
136 - 152
9. (Color 4)
153 - 169
10. (Color 4/Color 5)
170 - 186
11. (Color 5)
187 - 203
12. (Color 5/Color 6)
204 - 220
13. (Color 6)
221 - 237
14. (Color 6/Open)
238 - 255
15. (Open)
23
Color Wheel
2
0 - 255
0
Used as a control channel for different movement options of
Color
Control
Wheel 1.
0 - 5
Linear Movement using shortest (quickest) path.
6 - 10
Linear Movement using normal (longest) path.
11 - 15
Wheel Spin Forward (Fast to Slow)
16 - 20
Wheel Spin STOP
21 - 25
Wheel Spin Reverse (Slow to Fast)
26 - 56
Color Shake Quickest Path (Slow to Fast)
57 - 87
Color Shake Normal Path (Slow to Fast)
88 - 255
Reserved Values
24
Gobo Wheel
1
0 - 255
0
8-bit control of Gobo Wheel 2. See Channel 27 for control
options.
(Rotating
Gobo Wheel)
0 - 5
Open - No Gobo
6 - 10
Gobo 1 (Leafy Breakup) Index
11 - 15
Gobo 2 (Wavy Triangle) Index
16 - 20
Gobo 3 (Lattice) Index
21 - 25
Gobo 4 (Swirl) Index
26 - 30
Gobo 5 (Radial Breakup) Index
31 - 35
Gobo 6 (Neurons) Index
36 - 40
Gobo 7 (Grid) Index
41 - 45
Open - No Gobo
46 - 50
Gobo 1 (Leafy Breakup) Rotate
51 - 55
Gobo 2 (Wavy Triangle) Rotate
56 - 60
Gobo 3 (Lattice) Rotate
61 - 65
Gobo 4 (Swirl) Rotate
66 - 70
Gobo 5 (Radial Breakup) Rotate
71 - 75
Gobo 6 (Neurons) Rotate
76 - 80
Gobo 7 (Grid) Rotate
81 - 85
Open - No Gobo
86 - 90
Gobo 1 (Leafy Breakup) Rotate with Mega Stepping
91 - 95
Gobo 2 (Wavy Triangle) Rotate with Mega Stepping
17
96 - 100
Gobo 3 (Lattice) Rotate with Mega Stepping
101 - 105
Gobo 4 (Swirl) Rotate with Mega Stepping
106 - 110
Gobo 5 (Radial Breakup) Rotate with Mega Stepping
111 - 115
Gobo 6 (Neurons) Rotate with Mega Stepping
116 - 120
Gobo 7 (Grid) Rotate with Mega Stepping
121 - 255
Reserved Values
Gobo 1
Rot/Index
0 - 65535
32767
16-bit control of index and rotation of gobo wheel 1.
25
High Byte
0~126
Rotate Fast to Slow <<<
127~128
Rotation STOP
129- 255
Rotate Slow to Fast >>>
26
Low Byte
DMX
Channel
Parameter
Range DMX
Defaults
Description
27
Gobo Wheel
1
0 - 255
0
Used as a control channel for different movement options for
Control
Gobo Wheel 1 (Channel 24).
0 - 5
Gobo Selection using shortest (quickest) path.
6 - 10
Gobo Selection using normal (longest) path.
11 - 20
Reserved Values
21 - 50
Wheel Spin Forward (Fast to Slow)
51 - 60
Wheel Spin STOP
61 - 90
Wheel Spin Reverse (Slow to Fast)
91 - 120
Gobo Shake Quickest Path (Slow to Fast)
121 - 150
Gobo Shake Normal Path (Slow to Fast)
151 - 180
Gobo Twist Quickest Path (Slow to Fast)
181 - 210
Gobo Twist Normal Path (Slow to Fast)
211 - 255
Reserved Values
28
Gobo Wheel
2
0 - 255
0
8-bit control of Gobo Wheel 2. See Channel 27 for control
options.
(Rotating
Gobo Wheel)
0 - 5
Open - No Gobo
6 - 10
Gobo 1 (Night Sky) Index
11 - 15
Gobo 2 (Circle of Ovals) Index
16 - 20
Gobo 3 (Bricked Out) Index
21 - 25
Gobo 4 (Punch Card) Index
26 - 30
Gobo 5 (Alpha Rays) Index
31 - 35
Gobo 6 (HONEYCOMB) Index
18
36 - 40
Gobo 7 (On the Rocks) Index
41 - 45
Open - No Gobo
46 - 50
Gobo 1 (Night Sky) Rotate
51 - 55
Gobo 2 (Circle of Ovals) Rotate
56 - 60
Gobo 3 (Bricked Out) Rotate
61 - 65
Gobo 4 (Punch Card) Rotate
66 - 70
Gobo 5 (Alpha Rays) Rotate
71 - 75
Gobo 6 (HONEYCOMB) Rotate
76 - 80
Gobo 7 (On the Rocks) Rotate
81 - 85
Open - No Gobo
86 - 90
Gobo 1 (Night Sky) Rotate with Mega Stepping
91 - 95
Gobo 2 (Circle of Ovals) Rotate with Mega Stepping
96 - 100
Gobo 3 (Bricked Out) Rotate with Mega Stepping
101 - 105
Gobo 4 (Punch Card) Rotate with Mega Stepping
106 - 110
Gobo 5 (Alpha Rays) Rotate with Mega Stepping
111 - 115
Gobo 6 (HONEYCOMB) Rotate with Mega Stepping
116 - 120
Gobo 7 (On the Rocks) Rotate with Mega Stepping
121 - 255
Reserved Values
Gobo 2
Rot/Index
0 - 65535
32767
16-bit control of index and rotation of gobo wheel 1.
29
High Byte
0~126
Rotate Fast to Slow <<<
127~128
Rotation STOP
129- 255
Rotate Slow to Fast >>>
30
Low Byte
DMX
Channel
Parameter
Range DMX
Defaults
Description
31
Gobo Wheel
2
0 - 255
0
Used as a control channel for different movement options for
Control
Gobo Wheel 1 (Channel 24).
0 - 5
Gobo Selection using shortest (quickest) path.
6 - 10
Gobo Selection using normal (longest) path.
11 - 20
Reserved Values
21 - 50
Wheel Spin Forward (Fast to Slow)
51 - 60
Wheel Spin STOP
61 - 90
Wheel Spin Reverse (Slow to Fast)
91 - 120
Gobo Shake Quickest Path (Slow to Fast)
121 - 150
Gobo Shake Normal Path (Slow to Fast)
151 - 180
Gobo Twist Quickest Path (Slow to Fast)
181 - 210
Gobo Twist Normal Path (Slow to Fast)
211 - 255
Reserved Values
19
32
Iris
0 - 255
0
Controls Iris mechanism from open (DMX 0) to Full (DMX
255).
33
Prism
0 - 255
0
Controls Prism mechanism with following values.
0 - 5
Open
6 - 10
Index
11 - 15
Rotate Normal
16 - 20
Rotate with Mega Stepping
21 - 255
Reserved Values
Prism
Index/Rot
0 - 65535
32767
16-bit control of prism rotation and index.
34
High Byte
0~126
Rotate Fast to Slow <<<
127~128
Rotation STOP
129- 255
Rotate Slow to Fast >>>
35
Low Byte
36
Frost
0 - 255
0
Insert control of frost mechanism with the following values.
0 - 50
Open - No Frost or Diffusion
51 - 100
Insert Light Diffusion
101 - 150
Insert Heavy Frost
151 - 200
Insert both Light Diffusion and Heavy Frost
37
Strobe
0 - 255
0
Controls Strobe functionality.
0 - 3
Open
4 - 6
Closed
7 - 32
Normal Strobe - Slow to Fast
33 - 58
Random Strobe - Slow to Fast
59 - 84
Random Sync - Slow to Fast
85 - 110
Pulse > - Slow to Fast
111 - 136
Pulse > Random - Slow to Fast
137 - 162
Pulse > Random Sync - Slow to Fast
163 - 188
Pulse < - Slow to Fast
189 - 214
Pulse < Random - Slow to Fast
215 - 240
Pulse < Random Sync - Slow to Fast
38
Focus Timing
0 - 255
255
Adjustment of fixture timing to control Pan/Tilt mechanisms.
- See Timing Channel Chart in User Manual
39
Optics
Timing
0 - 255
255
Adjustment of fixture timing to control lensing mechanisms.
- See Timing Channel Chart in User Manual
20
DMX
Channel
Parameter
Range DMX
Defaults
Description
40
Color Timing
0 - 255
255
Adjustment of fixture timing to control color mechanisms.
- See Timing Channel Chart in User Manual
41
Beam Timing
0 - 255
255
Adjustment of fixture timing to control beam shaping
mechanisms.
- See Timing Channel Chart in User Manual
42
Gobo Timing
0 - 255
255
Adjustment of fixture timing to control gobo mechanisms.
- See Timing Channel Chart in User Manual
43
Luminaire
0 - 255
0
Control Channel used for full fixture settings, lamp controls, and
Control
miscellaneous modes.
Set descreet value of desired effect, wait >3 seconds, then set
value to 0 (Idle).
0 - 5
Idle (Default)
6 - 10
Full Luminaire ReCal - Also Used to Wake fixture up from
shutdown
11 - 15
Reserved Values
16 - 20
Reserved Values
21 - 25
Fixture Shutdown
26 - 30
Display - Menu ON
31 - 35
Display - Menu OFF
36 - 40
ReCal Position
41 - 45
ReCal Color
46 - 50
ReCal Gobo
51 - 55
ReCal Beam
56 - 60
ReCal Optics
61 - 65
ReCal Dimmer/Strobe
66 - 70
Reset Fixture to Defaults - See Manual for a list of factory
defaults.
71 - 75
Full Luminaire Reboot. This command will reset all processors
in
fixture, then ReCal all parameters.
76 - 80
Fixture Status On/Off. This command will enable the display
to
show fixture status for 5 min. After this time, displays will
return
to default configuration. Repeating this command in less than
5
minutes will behave as a toggle.
81 - 85
Standard Mode - Fixture operates at maximum output (Default)
86 - 90
Studio Mode - Reduced output with lower fan settings
91 - 255
Reserved Values
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22

Vari-Lite VLZ SPOT Guide de démarrage rapide

Catégorie
Stroboscopes
Taper
Guide de démarrage rapide

dans d''autres langues