Transition Networks J/E-CF-02 Manuel utilisateur

Catégorie
Convertisseurs de média réseau
Taper
Manuel utilisateur
User’s Guide
J/E-CF-02
Stand-Alone Media Converter
Ethernet
Copper to Fiber
10Base-T to 10Base-FL
Transition Networks J/E-CF-02 series
Ethernet 10Base-T to 10Base-FL media
converters connect 10 Mb/s twisted-pair
copper cable to 10 Mb/s fiber-optic
cable.
* Typical maximum cable distance. Actual distance is dependent upon the
physical characteristics of the network installation.
Optional Accessories: (sold separately)
Installation . . . . . . . . . . . . . . . . . .2
Operation . . . . . . . . . . . . . . . . . . .3
Cable Specifications . . . . . . . . . . .4
Technical Specifications . . . . . . . .5
Troubleshooting . . . . . . . . . . . . . .6
Contact Us . . . . . . . . . . . . . . . . . .7
Compliance Information . . . . . . . .8
Compliance Information
FCC Regulations
This equipment has been tested and found to comply with the limits for a class A digital
device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is
likely to cause harmful interference, in which case the user will be required to correct the
interference at the user's own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus
set out on the radio interference regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites
applicables aux appareils numériques de la class A prescrites dans le Règlement sur le
brouillage radioélectrique édicté par le ministère des Communications du Canada.
European Regulations
Warning
This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
Achtung !
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb
dieses Gerätes Rundfunkstörungen auftreten. In diesem Fäll is der Benutzer für
Gegenmaßnahmen verantwortlich.
Attention !
Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer
des interférences radioélectriques, il appartiendra alors à l'utilsateur de prende les measures
spécifiques appropriées.
Trademark Notice
All trademarks and registered trademarks are the property of their respective owners.
Copyright Restrictions
© 2003-2004 Transition Networks.
All rights reserved. No part of this work may be reproduced or used in any form or by any
means - graphic, electronic, or mechanical - without written permission from Transition
Networks.
Part Number Description
E-MCR-04 12-Slot media converter rack (includes universal internal power
supply) 17 x 15 x 5 in. (432 x 381 x 127 mm)
SPS-1872-SA Optional external power supply; 18-72VDC stand-alone
Output: 12.6VDC, 1.0 A
SPS-1872-CC Optional external power supply; 18-72VDC piggy-back
Output: 12.6VDC, 1.0 A
WMBS Optional wall mount brackets; length: 3.2 in. (81 mm)
WMBD Optional DIN Rail Mount Bracket; 5.0 in. (127 mm)
WMBD-FS Optional DIN Rail Mount Bracket (flat, small); 3.1in. (79 mm)
Part Number Port One - Copper Port Two - Duplex Fiber-Optic
J/E-CF-02 RJ-45, 10Base-T
100 m (328 ft)*
ST, 10Base-FL, 850 nm multimode
2 km (1.2 miles)*
J/E-CF-02(SC) RJ-45, 10Base-T
100 m (328 ft)*
SC , 10Base-FL, 850 nm multimode
2 km (1.2 miles)*
J/E-CF-02(SM) RJ-45, 10Base-T
100 m (328 ft)*
SC, 10Base-FL, 1310 nm single mode
20 km (12.4 miles)*
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE
PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in
damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-
Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der
Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über
Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer
Konformität.
In accordance with European Union Directive 2002/96/EC of the European
Parliament and of the Council of 27 January 2003, Transition Networks will accept
post usage returns of this product for proper disposal. The contact information for this
activity can be found in the 'Contact Us' portion of this document.
Printed in the U.S.A. 33272.E
Declaration of Conformity
Name of Mfg: Transition Networks
10900 Red Circle Drive, Minnetonka MN 55343 U.S.A.
Model: J/E-CF-02 Series Media Converters
Part Number(s): J/E-CF-02, J/E-CF-02(SC), J/E-CF-02(SM)
Regulation: EMC Directive 89/336/EEC; U.S.A. CFR
Purpose: To declare that the
J/E-CF-02
to which this declaration refers is in
conformity with the following standards.
EN 55022:1998 Class A; EN 55024:1998; FCC Part 15 subpart B; EN 61000-3-
2:2000; EN 61000-3-3:1995+A1:2001
I, the undersigned, hereby declare that the equipment specified above conforms to the above
Directive(s) and Standard(s).
April, 2007____
Stephen Anderson, Vice-President of Engineering Date
224-hour Technical Support: 1-800-260-1312 Int’l: 00-1-952-941-7600 [email protected] -- Click the “Transition Now” link for a live web chat. 7
J/E-CF-02
Installation
Install the fiber cable
1. Locate a 10Base-FL fiber cable with male, two-stranded TX to RX
connectors installed at both ends.
2. Connect the fiber cables to the J/E-CF-02 media converter as described:
Connect the male TX cable connector to the female TX port.
Connect the male RX cable connector to the female RX port.
3. Connect the fiber cables to the other device (another media converter,
hub, etc.) as described:
Connect the male TX cable connector to the female RX port.
Connect the male RX cable connector to the female TX port.
Install the copper cable
Note: Connections between the J/E-CF-02 and a hub, or a switch require
straight-through cable. Connections between the J/E-CF-02 and a
terminal, transceiver, router, or NIC require crossover cable cable.
(See page 4 for copper cable specifications.) Failure to observe this
caution will cause data transfer to fail.
1. Locate or build 10Base-T copper cables with male, RJ-45 connectors
installed at both ends.
2. Connect the RJ-45 connector at one end of the cable to the RJ-45 port on
the J/E-CF-02 media converter.
3. Connect the RJ-45 connector at the other end of the cable to the RJ-45
port on the other device (switch, workstation, etc.).
Contact Us
Technical Support
Technical support is available 24 hours a day.
US and Canada: 1-800-260-1312
International: 00-1-952-941-7600
Transition Now
Chat live via the Web with Transition Networks Technical Support.
Log onto www.transition.com and click the Transition Now link.
Web-Based Seminars
Transition Networks provides seminars via live web-based training.
Log onto www.transition.com and click the Learning Center link.
E-Mail
Ask a question anytime by sending an e-mail to our technical support staff.
Address
Transition Networks
10900 Red Circle Drive Minnetonka MN 55343, U.S.A.
telephone: 952-941-7600
toll free: 800-526-9267
fax: 952-941-2322
624-hour Technical Support: 1-800-260-1312 Int’l: 00-1-952-941-7600 [email protected] -- Click the “Transition Now” link for a live web chat. 3
J/E-CF-02
Installation -- Continued
Power the media converter
AC
1. Install the power adapter cord to the back of the media converter.
2. Connect the power adapter plug to AC power.
3. Verify that the media converter is powered by observing the illuminated
LED power indicator light.
DC
Consult the user’s guide for the Transition Networks SPS1872-xx DC external
power supply for powering the media converter.
Operation
Status LEDs
Use the status LEDs to monitor the media converter operation in the network.
Pwr On = Connection to external AC power.
Fiber On = A fiber link connection.
Flashing = No link or link is down.
Copper On = A copper link connection.
Flashing = No link or link is down.
Troubleshooting
If the media converter fails, isolate and correct the failure by determining the
answers to the following questions and then taking the indicated action:
1. Is the “Pwr” LED on the media converter illuminated?
NO
Is the power adapter the proper type of voltage and cycle frequency
for the AC outlet? (See “Power Supply” on page 5.)
Is the power adapter properly installed in the media converter and in
the outlet?
Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
YES
Proceed to step 2.
2. Is the “Copper” LED flashing?
NO
Check the copper cable for proper connection.
Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
YES
Proceed to step 3.
3. Is the “Fiber” LED flashing?
NO
Check the fiber cables for proper connection.
Verify that the TX and RX cables on the media converter are
connected to the RX and TX ports, respectively, on the other 10Base-
FL device.
Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
YES
Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
424-hour Technical Support: 1-800-260-1312 Int’l: 00-1-952-941-7600 [email protected] -- Click the “Transition Now” link for a live web chat. 5
J/E-CF-02
Cable Specifications
The physical characteristics must meet or exceed IEEE 802.3™ specifications.
Fiber cable
Bit Error Rate: <10-9
Single mode fiber (recommended): 9 µm
Multimode fiber (recommended): 62.5/125 µm
Multimode fiber (optional): 100/140, 85/140, 50/125 µm
J/E-CF-02 850 nm multimode
Fiber Optic Transmitter Power: min: -20.0 dBm max: -10.0 dBm
Fiber Optic Receiver Sensitivity: min: -32.5 dBm max: -7.2 dBm
Link Budget: 12.5 dB
J/E-CF-02(SC) 850 nm multimode
Fiber Optic Transmitter Power: min: -20.0 dBm max: -10.0 dBm
Fiber Optic Receiver Sensitivity: min: -32.5 dBm max: -7.2 dBm
Link Budget: 12.5 dB
J/E-CF-02(SM) 1310 nm single mode
Fiber-optic Transmitter Power: min: -23.0 dBm max: -10.0 dBm
Fiber-optic Receiver Sensitivity: min: -35.0 dBm max: -14.0 dBm
Link Budget: 12.0 dB
Copper cable
Category 3 (minimum requirement)
Gauge 24 to 22 AWG
Attenuation 11.5 dB/100m @ 5-10 MHz
Maximum Cable Distance 100 meters
Category 5 (recommended)
Gauge: 24 to 22 AWG
Attenuation: 22.0 dB /100m @ 100 MHz
Maximum Cable Distance: 100 meters
• Straight-through OR crossover cable may be used (see below).
• Shielded twisted-pair (STP) OR unshielded twisted-pair (UTP) may be used.
• Pins 1&2 and 3&6 are the two active pairs in an Ethernet network .
• RJ-45 Pin-out: Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD-
• Use only dedicated wire pairs for the active pins:
(e.g., blue/white & white/blue, orange/white & white/orange, etc.)
• Do not use flat or silver satin wire.
Crossover Cable
1
2
3
6
Straight-Through Cable
Twisted Pair #1
Twisted Pair #1
Twisted Pair #2
Twisted Pair #2
1
2
3
6
1
2
3
6
1
2
3
6
Technical Specifications
For use with Transition Networks Model J/E-CF-02 or equivalent.
Standards IEEE 802.3™
Data Rate 10 Mb/s
Case Dimensions 3.9" x 3.0" x 1.0" (99mm x 76mm x 25mm)
Weight 6 oz. (181 g)
Power Consumption 2.8 watts, 200 mA @ 13.9 VDC
Power Supply 12VDC, 0.5 Amp (North America)
DC Output 12VDC, 0.41 Amp (Europe, Japan, Latin Am.)
12VDC, 1.25 Amp (UK, Australia, South Africa)
MTBF (w/ power supply)53,077 hours (MIL217F2 V5.0)
(MIL-HDBK-217F) 124,650 hours (Bellcore7 V5.0)
Environment Tmra*: 0° to 50°C (32° to 122°F )
Storage Temp: -20° to 85°C (-4° to 185°F)
Humidity: 5 to 95%, non condensing
Altitude: 0 to 10,000 feet
Warranty Lifetime
*Manufacturer’s rated ambient temperature
The information in this user’s guide is subject to change. For the most up-to-date
information on the J/E-CF-02 media converter, view the user’s guide on-line at:
www.transition.com.
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR,
Subchapter J applicable at the date of manufacture.
WARNING: Visible and invisible laser radiation when open. Do not stare into
the beam or view the beam directly with optical instruments. Failure to observe
this warning could result in an eye injury or blindness.
WARNING: Use of controls, adjustments or the performance of procedures
other than those specified herein may result in hazardous radiation exposure.
CAUTION: Copper based media ports, e.g., Twisted Pair (TP) Ethernet, USB,
RS232, RS422, RS485, DS1, DS3, Video Coax, etc., are intended to be
connected to intra-building (inside plant) link segments that are not subject to
lightening transients or power faults. Copper based media ports, e.g., Twisted
Pair (TP) Ethernet, USB, RS232, RS422, RS485, DS1, DS3, Video Coax, etc., are
NOT to be connected to inter-building (outside plant) link segments that are
subject to lightening transients or power faults.
The fiber optic transmitters on this device meet Class I Laser safety requirements
per IEC-825/CDRH standards and comply with 21 CFR1040.10 and
21CFR1040.11.
Use straight-through cable when
connecting to a hub or switch.
Use crossover cable when
connecting to a terminal,
transceiver, router, or NIC.