Transition Networks TN-CWDM-SFP-1290 Manuel utilisateur

Catégorie
Convertisseurs de média réseau
Taper
Manuel utilisateur
*Unless otherwise indicated, the distances listed are the typical maximum cable
distance. The actual maximum cable distances are dependent upon the physical
characteristics of the network installation.
**Transition Networks' SFP modules fully comply with the Multi-Sourcing Agreement
(MSA). This compliance allows our SFP modules to be used in other MSA compliant
SFP platforms without problems. In
addition, TN SFP modules specified in
this manual are also compatible with all
Cisco SFP-based routers and switches, as
well as its IOS software. TN SFP
modules ARE NOT
Cisco OEM brand
modules.
User’s Guide
TN-GLC-xx-xx and TN-CWDM-SFP-1xx0 Cisco
CompatibleSmall Form Factor Pluggable (SFP)
Transceiver Modules**
The Transition Networks TN-GLC-xx-xx and TN-CWDM-
SFP-1xx0 series small form factor pluggable (SFP) transceiver
modules are designed to install in any SFP port, allowing for1000Base-T, 1000Base-SX
or 1000Base-LX interfaces to the network through the SFP connector. The TN-GLC-xxx
and TN-CWDM-SFP-1xx0 transceivers are designed for bi-directional serial-optical data
communications such as Gigabit Ethernet or fiber channel at speeds up to 2.125 Gbps.
Installation . . . . . . . . . . . . . . . . . . . . . . . . .3
Cable Specifications . . . . . . . . . . . . . . . . .5
Technical Specifications . . . . . . . . . . . . . .8
Contact Us . . . . . . . . . . . . . . . . . . . . . . . . .9
Compliance Information . . . . . . . . . . . . .11
Part Number Port Description
TN-GLC-T
1000Base-T , RJ-45
100m (328 ft)*
TN-GLC-SX-MM
1000Base-SX, duplex LC, 850 nm,
220 m (722 ft)* on 62.5/125 µm fiber
550 m (1840 ft)* on 50/125 µm fiber
TN-GLC-SX-MM-2K
1000Base-SX, duplex LC 1300 nm, extended multimode
up to 2 km (1.2 miles)*
TN-GLC-LH-SM
1000Base-LX, 1310 nm, single mode
10 km (6.2 miles)*
TN-GLC-BX-U
1000Base-BX, Simplex LC 1310 nm Tx/1490 nm Rx nm,
single mode, single fiber 10 km (6.2 miles)*
TN-GLC-BX-D
1000Base-BX, Simplex LC 1490 nm Tx/1310 nm Rx nm,
single mode, single fiber 10 km (6.2 miles)*
TN-GLC-SX-MM
TN-CWDM-SFP-1xx0
TN-GLC-BX-0
TN-GLC-T
TN-GLC-xx-xx SFPs
2
Tech Support: 1-800-260-1312 -- International: 00-1-952-941-7600—24 hours
Part Number Port Description
TN-GLC-BX-U
1000Base-BX, Simplex LC 1310 nm Tx/1490 nm Rx,
single mode, single fiber 10 km (6.2 miles)*
TN-GLC-BX-D
1000Base-BX, Simplex LC 1490 nm Tx/1310 nm Rx,
single mode, single fiber 10 km (6.2 miles)*
TN-GLC-BX-U-40
1000Base-BX, Simplex LC 1310 nm Tx/1490 nm Rx,
single mode, single fiber 40 km (24.9 miles)*
TN-GLC-BX-D-40
1000Base-BX, Simplex LC 1490 nm Tx/1310 nm Rx,
single mode, single fiber 40 km (24.9 miles)*
TN-GLC-BX-U-60
1000Base-BX, Simplex LC 1310 nm Tx/1490 nm Rx,
single mode, single fiber 60 km (37.3 miles)*
TN-GLC-BX-D-60
1000Base-BX, Simplex LC 1490 nm Tx/1310 nm Rx,
single mode, single fiber 60 km (37.3 miles)*
TN-GLC-FE-100BX-U
100Base-BX, Simplex LC 1310 nm Tx/1550 nm Rx,
single mode, single fiber 20 km (12.4 miles)*
TN-GLC-FE-100BX-D
100Base-BX, Simplex LC 1550 nm Tx/1310 nm Rx ,
single mode, single fiber 20 km (12.4 miles)*
TN-GLC-FE-100FX
100Base-BX, Duplex LC 1300 nm, multimode
2 km (1.2 miles)*
TN-GLC-FE-100LX
100Base-BX, Duplex LC 1310 nm, single mode
20 km (12.4 miles)*
TN-GLC-GE-100FX***
100Base-BX, Duplex LC 1300 nm, multimode
2 km (1.2 miles)*
TN-GLC-ZX-SM
1000Base-LX, 1550 nm, single mode
80 km (49.7 miles)*
TN-CWDM-SFP-1xx0
1000Base-LX, single mode
80 km (49.7 miles)*
27 =1270nm 39 = 1390nm 53 = 1530nm
29 = 1290nm 41 = 1410nm 55 = 1550nm
31 = 1310nm 43 = 1430nm 57 = 1570nm
33 = 1330nm 47 = 1470nm 59 = 1590nm
35 = 1350nm 49 = 1490nm 61 = 1610nm
37 = 1370nm 51 = 1510nm
xx = center wavelength (λ
c
) (See technical specifications for more details.)
*Unless otherwise indicated, the distances listed are the typical maximum cable
distance. The actual maximum cable distances are dependent upon the physical
characteristics of the network installation.
**Transition Networks' SFP modules fully comply with the Multi-Sourcing
Agreement (MSA). This compliance allows our SFP modules to be used in other
MSA compliant SFP platforms without problems. In addition, TN SFP modules
are also compatible with all Cisco SFP-based routers and switches, as well as its
IOS software. TN SFP modules ARE NOT
Cisco OEM brand modules.
[email protected] -- Click the “Transition Now” link for a live Web chat.
3
Installation
Installing the SFP transceiver
To install the SFP module into a network switches media converter, do the
following:
1. Position the module at the installation slot so that the label faces up.
2. Carefully slide the module into the installation slot, aligning it with the internal
installation guides.
Installing copper cables
1. Locate or build 1000Base-T compliant copper cables with male, RJ-45
connectors installed at both ends.
2. Connect the RJ-45 connector at one end of the cable to the RJ-45 port on the
media converter.
3. Connect the RJ-45 connector at the other end of the cable to the RJ-45 port on
the other device.
RJ-45 port
on the other device
(switch, work station, etc
.)
RJ-45 port
on the media
converter
***Provide 100Base-FX interface when plugged into a gigabit SFP slot on Cisco
catalyst 3750, 3560, and 2970 series switches.
Note: Install simplex or single fiber SFP models in pairs in the same network where
one is the local SFP and the other is the remote SFP.
TN-GLC-xx-xx SFPs
4
Tech Support: 1-800-260-1312 -- International: 00-1-952-941-7600 -- (24 hours)
Connect fiber cable
to media converter
as shown.
Connect fiber cable
to other device
(media converter,
hub, etc.) as shown
RX
TX
RX
TX
Installing the fiber cables
1. Locate or build 1000Base-SX-compliant or 1000Base-LX-compliant fiber
cable with male TX to RX connectors installed at both ends.
2. Install the fiber cable as shown below.
[email protected] -- Click the “Transition Now” link for a live Web chat.
5
Cable Specification
Copper cable (Category 5 -- minimum requirement)
Gauge = 24 to 22 AWG; Attenuation = 22.0 dB /100m @ 100 MHz
• Straight-through OR crossover cable may be used.
• Shielded twisted-pair (STP) OR unshielded twisted-pair (UTP) may be used
• All pin pairs (1&2, 3&6, 4&5, 7&8) are active in a gigabit network.
• Use only dedicated wire pairs for the active pins; e.g., blue/white &
white/blue,
orange/white & white/orange, etc.
• Do not use flat or silver satin wire.
Crossover Cable
1
2
3
6
Straight-Through Cable
T
wisted Pair #1
Twisted Pair #1
Twisted Pair #2
T
wisted Pair #2
1
2
3
6
1
2
3
6
1
2
3
6
TN-GLC-xx-xx SFPs
6
Tech Support: 1-800-260-1312 -- International: 00-1-952-941-7600 -- (24 hours)
Fiber cable
The physical characteristics must meet or exceed IEEE 802.3z specifications.
Singlemode fiber (recommended): 9 µm
Multimode fiber (recommended): 62.5/125 µm
Multimode fiber (optional): 100/140, 85/140, 50/125 µm
TN-GLC-SX-MM 850 nm multimode
Fiber Optic Transmitter Power: min: -9.5 dBm max: -3.5 dBm
Fiber Optic Receiver Sensitivity: min: -18.0 dBm max: -1.0 dBm
Link Budget: 8.5 dB
TN-GLC-SX-MM-2k 1300 nm multimode
Fiber Optic Transmitter Power: min: -9.0 dBm max: -1.0dBm
Fiber Optic Receiver Sensitivity: min: -19.0 dBm max: -1.0 dBm
Link Budget: 18.0 dB
TN-GLC-LH-SM 1310 nm singlemode
Fiber Optic Transmitter Power: min: -9.5 dBm max: -3.0 dBm
Fiber Optic Receiver Sensitivity: min: -20.0 dBm max: -3.0 dBm
Link Budget: 10.5 dB
TN-GLC-BX-U 1310 nm Tx/1490 nm Rx single mode
TN-GLC-BX-D 1490 nm Tx/1310 nm Rx single mode
Fiber Optic Transmitter Power: min: -9.0 dBm max: -1.0 dBm
Fiber Optic Receiver Sensitivity: min: -21.0 dBm max: -1.0 dBm
Link Budget: 12.0 dB
TN-GLC-BX-U-40 1310 nm Tx/1490 nm Rx single mode
TN-GLC-BX-D-40 1490 nm Tx/1310 nm Rx single mode
Fiber Optic Transmitter Power: min: -3.0 dBm max: +2.0 dBm
Fiber Optic Receiver Sensitivity: min: -23.0 dBm max: -1.0 dBm
Link Budget: 20.0 dB
TN-GLC-BX-U-60 1310 nm Tx/1490 nm Rx single mode
TN-GLC-BX-D-60 1490 nm Tx/1310 nm Rx single mode
Fiber Optic Transmitter Power: min: -2.0 dBm max: +4.0 dBm
Fiber Optic Receiver Sensitivity: min: -25.0 dBm max: -1.0 dBm
Link Budget: 23.0 dB
TN-GLC-FE-100BX-U 1310 nm Tx/1550 nm Rx single mode
TN-GLC-FE-100BX-D 1550 nm Tx/1310 nm Rx single mode
Fiber Optic Transmitter Power: min: -14.0 dBm max: -8.0 dBm
Fiber Optic Receiver Sensitivity: min: -32.0 dBm max: -0.0 dBm
Link Budget: 18.0 dB
Fiber cable -- continued
TN-GLC-FE-100FX 1300 nm multimode
TN-GLC-GE-100FX 1300 nm multimode
Fiber Optic Transmitter Power: min: -23.5 dBm max: -14.0 dBm
Fiber Optic Receiver Sensitivity: min: -32.0 dBm max: -8.0 dBm
Link Budget: 8.5 dB
TN-GLC-FE-100LX 1310 nm single mode
Fiber Optic Transmitter Power: min: -15.0 dBm max: -8.0 dBm
Fiber Optic Receiver Sensitivity: min: -34.0 dBm max: -0.0 dBm
Link Budget: 19.0 dB
TN-GLC-ZX-SM 1550 nm single mode
Fiber Optic Transmitter Power: min: 0.0 dBm max: +5.0 dBm
Fiber Optic Receiver Sensitivity: min: -24.0 dBm max: -3.0 dBm
Link Budget: 24 dB
TN-CWDM-SFP-1xx0 1270nm -1610nm single mode
Fiber Optic Transmitter Power: min: 0.0 dBm max: +5.0 dBm
Fiber Optic Receiver Sensitivity: min: -25.0 dBm max: -3.0 dBm
Link Budget: 25 dB
For the most up-to-date information on the TN-GLC-xx-xx transceiver module, view
the user’s guide on-line at: www.transition.com.
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR,
Subchapter J applicable at the date of manufacture.
WARNING:
Visible and invisible laser radiation when open. Do not stare into beam
or view directly with optical instruments. Failure to observe this warning could result
damage to your eyes or blindness.
WARNING:
Use of controls, adjustments or the performance of procedures other than
those specified herein could result in hazardous radiation exposure.
The fiber optic transmitters on this device meet Class I Laser safety requirements per
IEC-825/CDRH standards and comply with 21 CFR1040.10 and 21CFR1040.11.
[email protected] -- Click the “Transition Now” link for a live Web chat.
7
TN-GLC-xx-xx SFPs
8
Tech Support: 1-800-260-1312 -- International: 00-1-952-941-7600 -- (24 hours)
Technical Specification
For use with Transition Networks Model TN-GLC-xxx or equivalent.
Standard: IEEE 802.3 2003; ANSI X3.297-1997
TN-GLC-FE-xxx
and TN-GLC-GE-xxx: Compiant with
IEEE 802.3 100Base-Fx; IEEE802.3ah 100Base-Bx;
Intermediate - Reach Sonet OC-3/SDH STM-1 (s-1-1)
TN-GLC-xx-xx and TN-CWDM-SFP-1xx0 modules:
Compliant with IEEE 802.3z Gigabit Ethernet; FC-1x/2x SM-LC-L FC-PI.
TN-GLC-T modules: Compliant with IEEE 802.32 Gigabit
Ethernet (1000Base-T)
Output wavelength -6.0 <
λc < +7.5 nm
Dimensions: 0.52 x 2.18 x 0.33’’ (13.4 x 55.5 x 8.5 mm, Fiber)
0.95 x 2.8 x 0.54” (14-0 x 71.1 13.7 mm, Copper)
Weight: 1 oz. (28 g) approximately
Power: 3.3V, Fiber 0.66 W; Copper 1.0 W
Operating Temp: 0°C to 70°C (32°F to 158° F )
Storage Temp: -40°C to 85°C (-40° to 185°F)
Humidity: 5% to 95%, non-condensing
Altitude: 0 to 10,000 feet
Warranty: Lifetime
Note: Transition Networks' SFP modules fully comply with the Multi-Sourcing
Agreement (MSA). This compliance allows our SFP modules to be used in
other MSA compliant SFP platforms without problems. In addition, TN SFP
modules are also compatible with all Cisco SFP-based routers and switches, as
well as its IOS software and SMARTnet. TN SFP modules ARE NOT
Cisco
OEM brand modules.
[email protected] -- Click the “Transition Now” link for a live Web chat.
9
Contact Us
Technical support
Technical support is available 24 hours a day.
U.S.A. and Canada: 1-800-260-1312
International: 00-1-952-941-7600
Transition now
Chat live via the Web with Transition Networks Technical Support.
Log onto www.transition.com and click the Transition Now link.
Web-Based seminars
Transition Networks provides seminars via live web-based training.
Log onto www.transition.com and click the Learning Center link.
E-Mail
Ask a question anytime by sending an e-mail to our technical support staff.
Address
Transition Networks
10900 Red Circle Drive
Minnetonka, MN 55343, U.S.A.
telephone: 952-941-7600
toll free: 800-526-9267
fax: 952-941-2322
TN-GLC-xx-xx SFPs
10
Tech Support: 1-800-260-1312 -- International: 00-1-952-941-7600 -- (24 hours)
Declaration of Conformity
Name of Mfg: Transition Networks
10900 Red Circle Drive, Minnetonka MN 55343 U.S.A.
Model: TN-GLC-xx-xx Series Transceiver Modules
Part Number(s): TN-GLC-T, TN-GLC-SX-MM, N-GLC-SX-MM-2k,
TN-GLC-LH-SM, TN-GLC-BX-U, TN-GLC-BX-D,
TN-GLC-BX-U-40, TN-GLC-BX-D-40, TN-GLC-BX-U-60,
TN-GLC-BX-D-60, TN-GLC-FE-100BX-U,
TN-GLC-FE-100BX-D, TN-GLC-FE-100FX,
TN-GLC-FE-100LX, TN-GLC-GE-100LX, TN-GLC-ZX-SM,
TN-CWDM-SFP-1xx0
Regulation: EMC Directive 89/336/EEC
Purpose: To declare that the TN-GLC-xxx to which this declaration refers
is in conformity with the following standards:
IEC 60825-1; IEC60825-2; FC1X/2X SM-LC-L FC-PI; IEEE 802.3z 2003; ANSI X3.297
1997; Class A; FDA 21; CFR1040.10; CFR1040.11
I, the undersigned, hereby declare that the equipment specified above conforms to the above
Directive(s) and Standard(s).
October 2008____
Stephen Anderson, Vice-President of Engineering Date
[email protected] -- Click the Transition Now link for a live Web chat.
11
Compliance Information
CE Mark: IEC-60825; FDA 21; CFR 1040.10 and 1040.11
FCC regulations
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference, in which
case the user will be required to correct the interference at the user's own expense.
Canadian regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out
on the radio interference regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites
applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage
radioélectrique édicté par le ministère des Communications du Canada.
European regulations
Warning
This is a Class A product. In a domestic environment this product may cause radio interference in
which case the user may be required to take adequate measures.
Achtung !
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses
Gerätes Rundfunkstörungen auftreten. In diesem Fäll ist der Benutzer für Gegenmaßnahmen
verantwortlich.
Attention !
Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des
interférences radioélectriques, il appartiendra alors à l'utilsateur de prende les measures spécifiques
appropriées.
In accordance with European Union Directive 2002/96/EC of the European Parliament
and of the Council of 27 January 2003, Transition Networks will accept post usage
returns of this product for proper disposal. The contact information for this activity can
be found in the 'Contact Us' portion of this document.
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE
PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in
damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-
Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der
Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über
Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer
Konformität.
Trademark notice
All trademarks and registered trademarks are the property of their respective owners.
Copyright restrictions © 2004 Transition Networks. All rights reserved. No part of this work may
be reproduced or used in any form or means (graphic, electronic, mechanical) without written
permission from Transition Networks.
33389.D
Printed in the U.S.A.
TN-GLC-xx-xx SFPs
12
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

Transition Networks TN-CWDM-SFP-1290 Manuel utilisateur

Catégorie
Convertisseurs de média réseau
Taper
Manuel utilisateur

dans d''autres langues