Paasche DA400R Manuel utilisateur

Catégorie
Compresseurs d'air
Taper
Manuel utilisateur
INSTRUCTION Manual DA400R - 11/30/2016
WARNING: When a flammable liquid is sprayed, there may be
danger of fire or explosion especially in a closed room: keep
compressor at least 20 feet away from areas where hazardous
concentrations of flammable vapors are likely to occur. Disconnect
power before servicing.
ATTENTION: Lorsqu'un liquide inflammable est pulverise, il
peut y avoir danger d'incendie ou d'explosion, specialement
dans une piece fermee; garder le compresseur a au moins 20
pieds des endroits ou des concentrations dangereuses de
vapeurs inflammables sont susceptibles de se produire.
Debrancher avant toute maintenance.
Manufactured in China for Paasche
DA400R Air Compressor
1/4 HP, 120 Volts, 60 Cycle,
52 Dbs. Weight: 12 lbs (5.5 kg)
Features:
Portable & Lightweight
Low Noise Level
• Thermally Protected
Powerful & High Air Flow
Auto Stop and Start
Regulator & Moisture Trap
1/4” NPT Fittings
Carrying Handles
Compressor Specs:
• Twin Cylinder Piston
1/4 HP
110-120 Volt / 60 Cycle
0-50Working Pressure
(Depending on Airbrush)
12 lbs (5.5 kg)
Dim: 13”L x 5.5”W x 8”H
6 Foot Electric Cord
Operation Instructions:
1) Connect Air hose to male compressor fitting
2) Use Plumbers tape on threads to seal any air
leaks
3) Plug compressor into grounded outlet
4) Turn on compressor
5)
The regulator gauge will show the working
pressure. Use adjustment knob to set
desired pressure.
6) Ensure the working area is well ventilated
7) Compressor will run when your airbrush is
being triggered
Paasche Airbrush Company
4311 North Normandy Avenue
Chicago, IL 60634-1395
Phone: 773-867-9191 Fax: 773-867-9198
Website: paascheairbrush.com
This compressor is both
ETL & CE Listed
GENERAL & SAFETY INFORMATION
GENERAL INFORMATION
The maximum pressure of the compressor is 0-50 PSI . The maximum operating pressure while spraying will vary depending on size of
fluid tip, needle and aircap.
THERMAL PROTECTOR
The motor of this compressor has a thermal overload protector. If the motor should overheat, the overload protector will shut off the
motor. If this should occur, unplug the compressor and allow the motor to cool (approx. 5 minutes) and restart compressor.
SEALING OF AIR HOSE
When attaching the female pipe thread fitting from your air hose to the compressor, it may be necessary to use a quality pipe thread
sealant or PTFE pipe thread tape on the threaded air outlet of the compressor. Failure to do so may cause an air leak and your
compressor will not shut off as it should. NOTE: This unit does not require any lubricants or oil. Applying oil to any part could result in
damage to the compressor. All bearings, including those in the motor, are grease packed.
AUTOMATIC SHUT-OFF FEATURE
This compressor has a built-in pressure switch that automatically shuts-off the compressor when the airbrush is not in use. The
compressor will automatically stop when the airbrush is not in use. It will immediately start again as soon as the air is allowed to flow
through the airbrush.
GROUNDING INSTRUCTIONS
This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire
for the electric current. This product is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an
outlet that is properly installed and grounded in accordance with all local codes and ordinances.
EXTENSION CORDS – If it is necessary to use an extension cord, use a 3-wire extension cord that has a 3-blade grounding plug and
a 3-slot receptacle that will accept the plug on the product. Make certain your extension cord is in good condition. Make certain your
extension cord wire is not less than 16 gauge for 25 feet, 14 gauge for 50 feet and 12 gauge for 100 feet. An undersized cord will cause
a drop in line voltage resulting in loss of power and overheating. If in doubt, use the next heavier gauge. The smaller the gauge number,
the heavier the cord.
WARNINGS
• Only use 110-120 volt, 60 cycle power supply for this compressor.
• Before plugging in check to make sure compressor is in good condition.
• Only operate compressor in accordance with current safety regulations.
• Keep working area clean and uncluttered and make sure area is well ventilated. Never operate the compressor in the presence of
flammable liquids or gases.
• Compressor air can produce dust, dirt and loose particles it comes in contact with. To prevent possible injury always wear safety
goggles or glasses. Never point any nozzle or spray toward a person.
• The air compressor is powered by electricity. Like any electric device, if not used properly it can cause electric shock.
• Keep out of reach of children.
Suggested Accessories:
1) HFM manifolds. For multiple hose hook ups.  Each hose attachment has an open close valve.
Available in 2, 3, 4, 6, 8 & 10 outlets.
2) Hose adapter. If your hose has a 1/8” NPT fitting get the HF-592. For the opposite get HF-116.
3) A-194 Airbrush Holder
4) AC-7 Airbrush Cleaning Brushes.
  • Page 1 1
  • Page 2 2

Paasche DA400R Manuel utilisateur

Catégorie
Compresseurs d'air
Taper
Manuel utilisateur

dans d''autres langues