Paasche Airbrush D3000R Manuel utilisateur

Catégorie
Compresseurs d'air
Taper
Manuel utilisateur
INSTRUCTION AND PARTS LIST D3000R-8/31/2011
Supersedes Instruction & Parts List D3000-11/04/09
WARNING: When a flammable liquid is sprayed, there may be
danger of fire or explosion especially in a closed room: keep
compressor at least 20 feet away from areas where hazardous
concentrations of flammable vapors are likely to occur. Disconnect
power before servicing.
ATTENTION: Lorsqu'un liquide inflammable est pulverise, il
peut y avoir danger d'incendie ou d'explosion, specialement
dans une piece fermee; garder le compresseur a au moins 20
pieds des endroits ou des concentrations dangereuses de
vapeurs inflammables sont susceptibles de se produire.
Debrancher avant toute maintenance.
Manufactured for Paasche in China
Paasche Airbrush Company
4311 North Normandy Avenue
Chicago, IL 60634-1395
Phone: 773-867-9191 Fax: 773-867-9198
Website: paascheairbrush.com
D300 0 R Compr e s s or & Tank
1/8 HP, 110-120Volts, 60Hz, .30 CFM @ 30 PSI
Operating Pressure 20-40 Depending on airbrush
P.S.I., Shipping Weight: 5.6 kgs (12.2 lbs.),
ETL Listed.
OPERATION INSTRUCTIONS
Unpacking Instructions
When you unpack your unit, check carefully for damage that might have
occurred in transit.
Electrical Requirements:
This unit must only be used at the listed voltage. Low voltage will cause
the motor to overheat. Low voltage is recognized when the following
conditions exist:
1. Motor does not develop full power or speed.
2. A fuse blow out occurs at starting or when load is applied.
3. Lights dim when motor starts and remains dim.
Avoid excessive voltage drop by keeping extension cords as short as
possible. If it is necessary to use an extension cord, do not use less
than16 gauge for 25 feet, 14 gauge for 50 feet, or 12 gauge for 100 feet
or more.
GENERAL INFORMATION
The maximum pressure of the compressor is 50 PSI (4.3 Bar). The
maximun operating pressure while spraying will vary depending on size of
fluid tip, needle and/or aircap, etc.
THERMAL PROTECTOR
The motor of this compressor has a thermal overload protector. If the
motor should overheat, the overload protector will shut off the motor. If this
should occur, unplug the compressor and allow the motor to cool (approx.
5 minutes), remove excess load and restart compressor. If the
compressor fails to start, check for blown fuses. The compressor may
need to cool further before attempting to restart. If the overload protector
shuts off the motor frequently you may have a low voltage situation. Low
voltage can also be suspected when:
1. The motor does not get up to full power or speed.
2. Fuses or circuit breakers activate when starting compressor.
3. Lights dim or remain dim when compressor is started.
4. Other motor operated appliances fail to operate properly. Too many
motor operated appliances on same circuit.
SEALING OF AIR HOSE
When attaching the female pipe thread fitting from your air hose to the
compressor, it may be necessary to use a quality pipe thread sealant or
PTFE pipe thread tape on the threaded air outlet of the compressor.
Failure to do so may cause an air leak and your compressor will not shut
off as it should. NOTE: This unit does not require any lubricants or oil.
Applying oil to any part could result in damage to the compressor. All
bearings, including those in the motor, are grease packed. In case of
motor failure, return to authorized motor service station in your area.
AUTOMATIC SHUT-OFF FEATURE
This compressor has a built-in pressure switch that automatically shuts-
off the compressor when the airbrush is not in use once the maximum
tank pressure is reached. It will immediately start again as soon as the air
is allowed to flow through the airbrush bleeding off tank pressure.
GROUNDING INSTRUCTIONS
This product must be grounded. In the event of an electrical short circuit,
grounding reduces the risk of electric shock by providing an escape wire
for the electric current. This product is equipped with a cord having a
grounding wire with a grounding plug. The plug must be plugged into an
outlet that is properly installed and grounded in accordance with all local
codes and ordinances.
DANGER– Improper installation of the grounding plug can result in a risk
of electric shock.
If repair or replacement of the cord or plug is necessary, do not connect
the grounding wire to either flat blade terminal. The wire with insulation,
having an outer surface that is green with or without yellow stripes, is the
grounding wire. Check with a qualified electrician or serviceman if the
grounding instructions are not completely understood or if in doubt as to
whether the product is properly connected.
Do not modify the plug provided; if it will not fit the outlet, have the proper
outlet installed by a qualified electrician.
DANGER– Do not use temporary adapter plugs with this compressor.
EXTENSION CORDS – If it is necessary to use an extension cord, use a
3-wire extension cord that has a 3-blade grounding plug and a 3-slot
receptacle that will accept the plug on the product. Make certain your
extension cord is in good condition. Make certain your extension cord
wire is not less than 16 gauge for 25 feet, 14 gauge for 50 feet and 12
gauge for 100 feet. An undersized cord will cause a drop in line voltage
resulting in loss of power and overheating. If in doubt, use the next
heavier gauge. The smaller the gauge number, the heavier the cord.
SWITCH WITH SINGLE AND DOUBLE LINES CONTROLS THE WAY
COMPRESSOR SHUTS OFF. SET TO ONE LINE AND THE MOTOR
RUNS UNTIL PRESSURE IS AT TANK MAXIMUM - SET AT TWO
LINES AND THE MOTOR WILL RUN CONTINUOUSLY EVEN THOUGH
THE TANK IS FULL.
  • Page 1 1