mr.steam®
AromaSteam Operation and Installation Instructions
______________________________________________________________________________________________
___________________________________________________________________________________________________________________________________________
2014 © Sussman-Automatic Corporation I Mr.Steam and des., AromaFlo, AutoFlush, AutoSteam, Butler Package, ChromaSteam, Clean Steam...Every Time, Club Therapy, Digital 1, Express Steam, From
Bathroom to Spa, iGenie, iSizing, iSteam, iSteam/Plus, Making Wellness a Way of Life, MusicTherapy, Spa Package, Steam Genie, Steam on Demand, Steam@Home, SteamTherapy, Sussman, Valet
Package, Virtual Spa System, Voice Genie and Voice Wizard are registered trademarks of Sussman-Automatic Corporation. AudioWizard, A Lifetime of Pleasure, Home Wizard, iButler,
iSteamTV, iTempo, iTempo/Plus, MySteam, Smart Sizing, Steam in a Box, SteamStart, SteamStop, The Intelligent Steambath are trademarks of Sussman-Automatic Corporation.
PUR
100402 10.14
8
TROUBLESHOOTING
TO AVOID ELECTRIC SHOCK, DISCON-
NECT POWER TO PUMP BEFORE SERVICING
Metering pump does not prime
1. Check if voltage is available.
2. Check liquid level in scent container. Replenish liquid, if
necessary.
3. Check for air bubbles in the suction hose or the pump
head. To eliminate air bubbles see: Priming Pump.
4. Check valves for contamination. Clean valves, if
necessary.
5. Check filter in container for contamination.
Rinse filter under clean water.
Metering pump does not inject oil into
steam room
1. Check if voltage is available.
2. Check liquid level in scent container. Replenish liquid
if necessary.
3. Check for air bubbles in the suction hose or the pump
head. To eliminate air bubbles see: Priming Pump.
4. Check valves for contamination. Clean valves,
if necessary.
5. Check filter in container for contamination.
Rinse filter under clean water.
6. Check the pressure hose for kinking or jamming.
Straighten or replace.
7. Check if liquid is freely flowing through the atomizing
nozzle when the metering pump is energized. Apply
compressed air through the atomizing nozzle. Attach
the compressed air at the point of connection of the
pressure hose.
8.
For iTempoPlus: ensure the demand button light is ON.
The demand button light should be pressed during
installation, the light will turn on. In the event of a power
outage the button will need to be pressed again.
Metering pump oil delivery too much
or too little
Contact Mr.Steam technical service personnel at
1-800-76 STEAM (East Coast) or 1-800-72-STEAM
(West Coast).
Dimensions: 11.5"W x 9.5"H x 4.5"D
Weight: 5 pounds
Motor voltage 120VAC, 50/60 Hz
Power consumption, total [W] 12 Watt
________________________________________
TECHNICAL SPECIFICATIONS
LIST OF SPARE PARTS
Description Part No.
Pump Head 103861
Pressure/Suction Hose EO1-1032
(ordered by the foot)
Eucalyptus oil, 1 liter MS OIL 1
Lavender oil, 1 liter MS OIL 2
Evergreen oil, 1 liter MS OIL 3
Energizing Mint oil, 1 liter MS OIL 4
Poho oil, 1 liter MS OIL 5
Atomizing Nozzle 103918
Oil Injector 103983
Filter 103987
Valve Rebuild Kit 104159
WARNING
!
WARRANTY:
To view or download
the Mr. Steam®Control Warranty
and register your product go to
:
blog.mrsteam.com/wr