Intermec ScanPlus 1802 Getting Started Manual

Taper
Getting Started Manual
Getting Started
Guide
ScanPlus 1802
Cordless System
2 3
Step 1
Step 2
Step 3
Quick setup
PC Keyboard wedge cable or USB Cable .......... 4
RS-232 C cable
............................................................6
Return to the default setup.............................................. 9
Using more than one Cordless System ........................
9
Use the EasySet software for additional setup
options..................................................................................10
Operating your Cordless System.................................11
Add more scanners to your system.............................11
Test bar codes.....................................................................16
Read the Recommendations...............................................3
Choose your connection:
Select symbologies for your scanners .............................8
If necessary . . .
The ScanPlus Cordless System consists of a base station (MicroBar 9735) and at
least one scanner (ScanPlus1802).
2 3
Step 1
Recommendations
Recommended Not recommended
0 - 15 m
(0 - 50 ft)
15 - 25 m
(50 - 80 ft)
The MicroBar 9735 must not be connected by the RJ connectors to any type of telecom-
munications circuits.
4
Step 2
PC wedge cable
P/N 3-414037-11
Keyboard wedge or USB (PC)
Connect base station
System power OFF
System power ON
Associate cordless scanner(s)
Recharge battery
"beep beep"
Only do this if you are using a Keyboard wedge or a USB cable.
USB cable
P/N 3-414038-11
port 3
Keyboard wedge cable
USB cable
5
AZERTY French
QWERTZ German
QWERTY English
Select keyboard
QWERTY Italian
QWERTY Danish
QWERTZ Swiss / French
QWERTY Swedish / Finnish
QWERTY Spanish
QWERTY Portuguese
QWERTY Norwegian
Postamble = Carriage Return
Postamble = Tab
Postamble = Enter (*)
Postamble = none
Customize parameters (optional)
(*) = default value
6 7
Step 2
Read this code (standard RS-
232 C PC serial port compa-
tible)
9600 baud, 7 data bits, even parity, 2 stop bits
postamble = carriage return + line feed
Associate cordless scanner(s)
System power ON
Connect base station
Direct RS-232 cable
P/N 3-414032-10
System power OFF
Recharge battery
"beep beep"
power supply
RS-232 C
Only do this if you are using an RS-232 C cable.
6 7
Customize parameters (optional)
(*) = default value
Postamble = Carriage Return + Line Feed (*)
Postamble = none
Postamble = Carriage Return
Even parity
No parity
Odd parity
7 data bits
8 data bits
19200 baud
9600 baud
8 9
PDF417
Code 39
Code 128 / EAN 128
UPC-A, UPC-E, EAN-8, EAN-13
(UPC-A -> UPC-A)
UPC-A, UPC-E, EAN-8, EAN-13
(UPC-A -> EAN-13)
Step 3
Symbologies
Select symbology
Disable all symbologies
Set symbologies for each cordless scanner.
Use the bar codes on the back cover to test your setup
8 9
Default setup
Using more than one Cordless System
When using more than one cordless system in the same area, we strongly
recommend using dierent channels for optimal performance.
North American version 906MHz - channel 2
European version 433MHz - channel 5
channel 1 channel 2
10 11
Full setup with EasySet
Connect base station
Associate cordless scanner(s)
Start the EasySet software
Send setup bar codes to the EasySet setup sheet
Print setup sheet
Read the bar codes on the setup sheet
"beep beep"
10 11
Operation
read barcode
good read "beep"
data transmission
data transmission
acknowledgement
Add more scanners
You can associate more cordless scanners with the base station at any time.
Set symbologies (see page 8)
Read association bar code
out of range
"beep beep beep beep beep beep"
low battery
"beep beep"
12 13
Regulatory statements
Intermec hereby declares that the ScanPlus 1802 Cordless System has been tested and found compliant with the
below listed standards as required by the R&TTE Directive 99/05/EC, EMC Directive 89/336/EEC as amended by
92/31/EEC and by the Low Voltage Directive 73/23/EEC as amended by 93/68/EEC: ETS 300 683, EN 301 489, EN
300 220-1 (1999), EN 60950 and EN 60825-1. This device is TÜV GS licensed (EN 60950 and EN 60825-1) for safety
only when powered by an external Intermec power supply. The original Declaration of Conformity is available on demand.
The ScanPlus 1802 Cordless System is certied for use in all countries belonging to the European Union.
USA & Canada: This device complies with Part 15 of the FCC rules and RSS-210 of Industry Canada. Operation is subject
to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC
rules. These limits are designed to provide a reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy. If not installed and used in accordance with the
instructions, it may cause harmful interference to radio communications. However there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference, the user is encouraged to try
to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna, increase
the separation between the equipment and the receiver, connect the equipment into an outlet on a circuit dierent from
that to which the receiver is connected or consult the dealer or an experienced radio/TV technician for help.
In order to maintain compliance with the FCC Rules, the I/O cables that interconnect between the device and any peripheral
must be as specied by Intermec.
Caution: Changes or modications not expressly approved by Intermec could void the user's authority to operate this
equipment.
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. This
device requires a radio license unless it is used totally inside a building (the user must obtain this license).
This device complies with the UL standards (UL1950 / C22.2 n°950).
Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
Cet appareil exige une licence radio à moins d'être entièrement installé dans un bâtiment (l'utilisateur doit obtenir cette
licence).
Cet équipement est conforme aux exigences du CNR-210 de Industrie Canada. L'utilisation de ce dispositif est autorisée aux
conditions suivantes: (1) il ne doit pas produire de brouillage, et (2) l'utilisateur de l'équipement doit accepter tout brouillage
reçu, même si ce brouillage est susceptible de compromettre son fonctionnement.
Cet équipement est conforme aux normes UL (UL1950 / C22.2 n°950).
Australia-New Zealand: This equipment has been tested and found to conform to the Australian
EMC framework concerning Class B digital devices, prescribed by the Australian and New-Zealand
standard AS/NZS 3548.
The information contained in this document is for informational purposes only and is subject to change without notice.
No part of this document may be copied or reproduced in any manner without the prior written permission of Intermec
Technologies Corporation.
ScanPlus/MicroBar products are covered by patents issued or pending in the USA and other countries.
The word Intermec, the Intermec logo, ScanPlus, MicroBar are either trademarks or registered trademarks of Intermec
Technologies Corporation.
EsaySet® is a registered trademark of Intermec Technologies Corporation.
Throughout this document, trademarked names may be used. Rather than put a trademark (™ or ®) symbol in every
occurrence of a trademarked name, we state that we are using the names only in an editorial fashion, and to the benet of
the trademark owner, with no intention of infringement.
Class 1 LED product - safe when used in any reasonable operating conditions.
N309
12 13
North America / Asia Pacific / Latin America 6001 36th Avenue West, PO Box 4280, Everett, WA 98203-9280
Tel: +1 425 348 2600 Fax: +1 425 348 2833 U.S. service and technical support, tel: + 1 800 755 5505 Canadian service
and technical support, tel: + 1 800 668 7043
Europe / Middle East / Africa Sovereign House, Vastern Road, Reading RG1 8BT, England
Tel: +44 118 987 9400 • Fax: +44 118 987 9401
Internet: http://www.intermec.com
E-mail: info@intermec.com
Test barcodes
Part Number: 3-235049-01 Rev. JAll Rights Reserved© 2006 Intermec Technologies Corporation
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Intermec ScanPlus 1802 Getting Started Manual

Taper
Getting Started Manual

dans d''autres langues