Stanley STHT77611 Manuel utilisateur

Taper
Manuel utilisateur
STHT77611
Self-Leveling Cross-line Laser
E
PT
ES
F
Please read these instructions before operating the product.
www.STANLEYTOOLS.com
> 4
o
± 4
o
=
=
1 2
3
Figures
2
A
3
1/4-20
C
B
ab
≥ 30 ft. (9m)
ab
a
c
b
b
1
2
3
5
E
1
2
3
7
G
8
E
Contents
• Laser Information
• User Safety
• Battery Safety
• Installing AA Batteries
• Turning the Laser On
• Checking Laser Accuracy
• Using the Laser
• Maintenance
• Troubleshooting
• Service and Repairs
• Specications
Laser Information
The STHT77611 is a Class 2 laser product. The
lasers are self-levelling laser tools that can be used
for horizontal (level) and vertical (plumb) alignment
projects.
User Safety
Safety Guidelines
The denitions below describe the level of severity for
each signal word. Please read the manual and pay
attention to these symbols.
DANGER: Indicates an imminently hazardous
situation which, if not avoided, will result in
death or serious injury.
WARNING: Indicates a potentially hazardous
situation which, if not avoided, could result in
death or serious injury.
CAUTION: Indicates a potentially hazardous
situation which, if not avoided, may result in
minor or moderate injury.
NOTICE: Indicates a practice not related to personal
injury which, if not avoided, may result in property
damage.
If you have any questions or comments about this
or any STANLEY
®
tool, go to
www.STANLEYTOOLS.com.
WARNING:
Read and understand all instructions.
Failure to follow the warnings and instructions
in this manual may result in serious personal
injury.
SAVE THESE INSTRUCTIONS
WARNING:
Laser Radiation Exposure. Do not
disassemble or modify the laser level.
There are no user serviceable parts inside.
Serious eye injury could result.
WARNING:
Hazardous Radiation. Use of controls or
adjustments, or performance of procedures,
other than those specied herein may result in
hazardous radiation exposure.
The label on your laser may include the following
symbols.
Symbol Meaning
V Volts
mW Milliwatts
Laser Warning
nm Wavelength in nanometers
2 Class 2 Laser
Warning Labels
For your convenience and safety, the following labels
are on your laser.
WARNING: To reduce the risk of injury,
user must read instruction manual.
WARNING: LASER RADIATION. DO
NOT STARE INTO BEAM. Class 2 Laser
Product.
9
E
www.STANLEYTOOLS.com
Complies with 21 CFR 1040.10 and 1040.11
except for deviations pursuant to Laser Notice
No. 50, dated June 24, 2007.
TYPE 1: 3VDC
Made in China
STHT77611
If the equipment is used in a manner not
specied by the manufacturer, the protection
provided by the equipment may be impaired.
Do not operate the laser in explosive
atmospheres, such as in the presence of
ammable liquids, gases, or dust. This tool may
create sparks which may ignite the dust or fumes.
Store an idle laser out of reach of children and
other untrained persons. Lasers are dangerous in
the hands of untrained users.
Tool service MUST be performed by qualied
repair personnel. Service or maintenance
performed by unqualied personnel may result in
injury. To locate your nearest Stanley service center
go to www.STANLEYTOOLS.com.
Do not use optical tools such as a telescope or
transit to view the laser beam. Serious eye injury
could result.
Do not place the laser in a position which may
cause anyone to intentionally or unintentionally
stare into the laser beam. Serious eye injury could
result.
Do not position the laser near a reective
surface which may reect the laser beam toward
anyone’s eyes. Serious eye injury could result.
Turn the laser off when it is not in use. Leaving
the laser on increases the risk of staring into the
laser beam.
Do not modify the laser in any way. Modifying
the tool may result in hazardous laser radiation
exposure.
Do not operate the laser around children or allow
children to operate the laser. Serious eye injury
may result.
Do not remove or deface warning labels. If labels
are removed, the user or others may inadvertently
expose themselves to radiation.
Position the laser securely on a level surface. If
the laser falls, damage to the laser or serious injury
could result.
Personal Safety
Stay alert, watch what you are doing, and use
common sense when operating the laser. Do not use
the laser when you are tired or under the inuence
of drugs, alcohol, or medication. A moment of
inattention while operating the laser may result in
serious personal injury.
Use personal protective equipment. Always wear
eye protection. Depending on the work conditions,
wearing protective equipment such as a dust
mask, non-skid safety shoes, hard hat, and hearing
protection will reduce personal injury.
Tool Use and Care
Do not use the laser if the Power/Transport Lock
switch does not turn the laser on or off. Any tool that
cannot be controlled with the switch is dangerous
and must be repaired.
Follow instructions in the Maintenance section of
this manual. Use of unauthorized parts or failure to
follow Maintenance instructions may create a risk of
electric shock or injury.
10
E
FCC Statement
This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful
interference in a residential installation. This equipment
generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance
with the instructions, may cause harmful interference
to radio communications. However, there is no
guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful
interference to radio or television reception, which can
be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by
one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and
receiver.
- Connect the equipment into an outlet on a different
circuit (not the circuit to which the receiver is
connected).
- Consult the dealer or an experienced radio/TV
technician for help.
Canada, Industry Canada (IC) Notices
This Device complies with Industry Canada License-
exempt RSS standard(s). Operation is subject to the
following two conditions: 1) this device may not cause
interference, and 2) this device must accept any
interference, including interference that may cause
undesired operation of the device.
Under Industry Canada regulations, this radio
transmitter may only operate using an antenna of a
type and maximum (or lesser) gain approved for the
transmitter by Industry Canada. To reduce potential
radio interference to other users, the antenna type
and its gain should be so chosen that the equivalent
isotropically radiated power (e.i.r.p.) is not more than
that necessary for successful communication.
Battery Safety
WARNING:
Batteries can explode, or leak, and can
cause injury or re. To reduce this risk:
Carefully follow all instructions and warnings on the
battery label and package.
Always insert batteries correctly with regard to
polarity (+ and –), as marked on the battery and the
equipment.
Do not short battery terminals.
Do not charge disposable batteries.
Do not mix old and new batteries. Replace all
batteries at the same time with new batteries of the
same brand and type.
Remove dead batteries immediately and dispose of
per local codes.
Do not dispose of batteries in re.
Keep batteries out of reach of children.
Remove batteries when the device is not in use.
Installing AA Batteries
Load new AA batteries in the STHT77611 laser.
1.
Turn the laser upside down.
2.
On the bottom of the laser, lift up the latch to open
the battery compartment cover (Figure
B
1
).
3.
Insert two new, high-quality, name brand AA
batteries, making sure to position the - and +
ends of each battery as noted inside the battery
compartment (Figure
B
2
).
4.
Push the battery compartment cover closed until it
snaps in place (Figure
B
3
).
When the laser is not in use, keep the Power/
Transport Lock switch in the center (OFF) position
(Figure
A
2
) to save battery power.
11
E
Turning the Laser On
1.
Place the laser on a smooth, flat, level surface,
with the laser facing straight ahead toward the
opposing wall.
2.
Turn the laser ON to display the horizontal and
vertical laser beams. Either:
Move the Power/Transport Lock switch to the
left to keep the pendulum locked and display the
cross beams in manual mode (Figure
A
1
).
• Move the Power/Transport Lock switch to the
right to unlock the pendulum and display the
cross beams in self-leveling mode (Figure
A
3
).
3.
Check the horizontal and vertical laser beams.
If the laser is tilted so much that it cannot self-
level (> 4°), or the laser is not level in manual
mode, the laser beams will flash.
If the laser beams ash, the laser is not level (or
plumb) and should NOT BE USED for determining
or marking level or plumb. Try repositioning the
laser on a level surface.
4.
If ANY of the following statements are TRUE,
continue with the instructions for Checking Laser
Accuracy BEFORE USING THE LASER for
a project.
This is the first time you are using the laser
(in case the laser was exposed to extreme
temperatures).
The laser has not been checked for accuracy
in a while.
The laser may have been dropped.
Checking Laser Accuracy
The laser tools are sealed and calibrated at the factory.
It is recommended that you perform an accuracy check
prior to using the laser for the rst time (in case the
laser was exposed to extreme temperatures) and then
regularly to ensure the accuracy of your work. When
performing any of the accuracy checks listed in
this manual, follow these guidelines:
Use the largest area/distance possible, closest
to the operating distance. The greater the area/
distance, the easier to measure the accuracy of
the laser.
Place the laser on a smooth, at, stable surface
that is level in both directions.
Mark the center of the laser beam.
Horizontal Beam - Scan Direction
Checking the horizontal scan calibration of the
laser requires two walls at least 30′ (9m) apart. It
is important to conduct a calibration check using
a distance no shorter than the distance of the
applications for which the tool will be used.
1.
Place the back of the laser against a wall and facing
straight ahead toward the opposing wall.
2.
Move the Power/Transport Lock switch to the right
(Figure
A
3
) to turn the laser ON in self-leveling
mode and display the horizontal and vertical beams.
3.
Turn the laser 45º counter-clockwise so that the
right-most end of the laser line is displayed on the
wall (Figure
D
1
).
4.
Mark
a
on the center of the beam on the wall.
5.
Turn the laser 90º clockwise so that the left-most
end of the laser line is displayed near
a
(Figure
D
2
).
6.
Mark
b
on the center of the beam on the wall.
7.
Measure the vertical distance between
a
and
b
.
12
E
8.
If your measurement is greater than the
Allowable Distance Between
a
and
b
for the
corresponding Distance Between Walls in the
following table, the laser must be serviced at an
authorized service center.
Distance
Between Walls
Allowable Distance
Between
a
and
b
30 (9m) 7/16” (11.0mm)
40 (12m) 9/16” (14.4mm)
50 (15m) 23/32” (18.0mm)
Horizontal Beam - Pitch Direction
Checking the horizontal pitch calibration of the
laser requires a single wall at least 30 (9m)
long. It is important to conduct a calibration
check using a distance no shorter than the
distance of the applications for which the tool
will be used.
1.
Place the laser against the end of the wall
(Figure
E
1
).
2.
Move the Power/Transport Lock switch to
the right (Figure
A
3
) to turn the laser ON in
self-leveling mode and display the horizontal
and vertical beams.
3.
At least 30(9m) apart along the laser
beam, mark
a
and
b
.
4.
Move the laser to the opposite end of the
wall (Figure
E
2
).
5.
Position the laser toward the rst end of the
same wall and parallel to the adjacent wall.
6.
Adjust the height of the laser so the center
of the beam is aligned with
b
.
7.
Directly above or below
a
, mark
c
along
the laser beam (Figure
E
3
).
8.
Measure the distance between
a
and
c
.
9.
If your measurement is greater than the
Allowable Distance Between
a
and
c
for
the corresponding Distance Between
a
and
b
in the following table, the laser must
be serviced at an authorized service center.
Distance Between
a
and
b
Allowable Distance
Between
a
and
c
30 (9m) 7/16” (11.0mm)
40 (12m) 9/16” (14.4mm)
50 (15m) 23/32” (18.0mm)
Vertical Beam - Plumb
Checking the vertical (plumb) calibration of the
laser can be most accurately done when there is
a substantial amount of vertical height available, ideally
30 (9m), with one person on the oor positioning
the laser and another person near a ceiling to mark
the position of the beam. It is important to conduct
a calibration check using a distance no shorter than
the distance of the applications for which the tool will
be used.
1.
On the oor between two walls, mark a 5 ft. (1.5
m) line that is parallel to the adjacent wall (Figure
F
1
).
2.
Move the Power/Transport Lock switch to the right
(Figure
A
3
) to turn the laser ON in self-leveling
mode and display the horizontal and vertical beams.
3.
Place the laser at one end of the line on the oor,
making sure the vertical laser beam is aligned and
centered on the line.
4.
Where the vertical laser beam appears on the
ceiling, mark
a
. (This should be directly over the
midpoint of the line on the oor.)
5.
Move the laser to the other end of the line on the
oor (Figure
F
2
).
13
E
6.
Where the vertical laser beam appears on the
ceiling, mark
b
, directly beside the rst mark
a
.
7.
Measure the distance between
a
and
b
.
8.
If your measurement is greater than the
Allowable Distance Between
a
and
b
for the
corresponding Ceiling Height
D
in the following
table, the laser must be serviced at an authorized
service center.
Ceiling Height
D
Allowable Distance
Between
a
and
b
8′ (2.5m) 1/8" (3.0mm)
10′ (3.0m) 5/32” (3.6mm)
14′ (4.0m) 7/32” (4.8mm)
20′ (6.0m) 5/16” (7.2mm)
30′ (9.0m) 15/32” (10.8mm)
Using the Laser
Operating Tips
Always mark the center of the beam created by
the laser.
Extreme temperature changes may cause
movement of internal parts that can affect accuracy.
Check your accuracy often while working.
If the laser is ever dropped, check to make sure it is
still calibrated.
As long as the laser is properly calibrated, the laser
is self-leveling. Each laser is calibrated at the factory
to nd level as long as it is positioned on a at
surface within average ± 4° of level. No manual
adjustments are required.
Use the laser on a smooth, at, level, surface.
Turning the Laser Off
Slide the Power/Transport Lock switch to the OFF
position (Figure
A
2
) when the laser is not in use. If
the switch is not placed in the OFF position, the laser
will not turn off.
Using the Laser with the Bracket
A bracket (Figure
G
) is included with the laser so you
can easily attach the laser to a stud or wall.
Securely attach the laser to the bracket.
• Using the 1/4-20 thread on the bottom of the laser
(Figure
G
1
), position the laser on the 1/4-20
thread on the bracket arm (Figure
G
2
).
• Turn the bracket knob (Figure
G
3
) clockwise to
lock the laser on the 1/4-20 thread on the bracket
arm.
The L Bracket has a 1/4-20 male thread on which
to attach the laser, and magnets and a keyhole for
hanging the laser from a wall.
Using the Laser with Other Accessories
WARNING:
Since accessories other than those offered
by STANLEY have not been tested with this
laser, use of such accessories with this laser
could be hazardous.
Only use STANLEY
®
accessories that are
recommended for use with this model. Accessories
that may be suitable for one laser may create a risk of
injury when used with another laser.
The laser is equipped with a 1/4-20 female thread on
the bottom (Figure
C
) to accommodate current or
future STANLEY
®
accessories.
Other recommended accessories for use with this
laser are available at extra cost from your local dealer
or authorized service center. If you need assistance
locating any accessory, please contact your nearest
STANLEY service center or visit our website: www.
STANLEYTOOLS.com.
14
E
Maintenance
When the laser is not in use, clean the exterior parts
with a damp cloth, wipe the laser with a soft dry cloth
to make sure it is dry, and then store the laser in the
kit box provided.
Although the laser exterior is solvent resistant,
NEVER use solvents to clean the laser.
Do not store the laser at temperatures below -5 ˚F
(-20 ˚C) or above 140 ˚F (60 ˚C).
To maintain the accuracy of your work, check the
laser often to make sure it is properly calibrated.
Calibration checks and other maintenance repairs
may be performed by STANLEY service centers.
Troubleshooting
The Laser Does Not Turn On
Check the AA batteries to make sure:
Each battery is installed correctly, according to (+)
and (–) listed inside the battery compartment.
The battery contacts are clean and free of rust or
corrosion.
The batteries are new, high-quality, name brand
batteries to reduce the chance of battery leakage.
Make sure the AA batteries are in proper working
condition. If in doubt, try installing new batteries.
When using rechargeable batteries, make sure the
batteries are fully charged.
Be sure to keep the laser dry.
If the laser has been stored in extremely hot
temperatures, allow it to cool. The laser level will
not be damaged by using the Power/Transport
Lock switch before cooling to its proper operating
temperature.
The Laser Beams Flash
When in self-levelling mode, the lasers are designed
to self-level up to an average of 4° in all directions. If
the laser is tilted so much that the internal mechanism
cannot level itself (or the laser is not level when in
manual mode), the laser beams will ash indicating
that the tilt range has been exceeded.
THE FLASHING BEAMS CREATED BY THE LASER
ARE NOT LEVEL OR PLUMB AND SHOULD NOT BE
USED FOR DETERMINING OR MARKING LEVEL
OR PLUMB. Try repositioning the laser on a more
level surface.
The Laser Beams Will Not Stop Moving
The laser is a precision instrument. Therefore, if it is
not positioned on a stable (and motionless) surface,
the laser will continue to try to nd level. If the beam
will not stop moving, try placing the laser on a more
stable surface. Also, try to make sure that the surface
is relatively at and level, so that the laser is stable.
Service and Repairs
Note: Disassembling the laser level will void all
warranties on the product.
To assure product SAFETY and RELIABILITY, repairs,
maintenance and adjustment should be performed by
authorized service centers. Service or maintenance
performed by unqualied personnel may result in a risk
of injury. To locate your nearest STANLEY
service
center, go to www.STANLEYTOOLS.com.
Warranty
Go to www.STANLEYTOOLS.com for the latest
warranty information.
15
E
Specications
STHT77611
Light Source Laser diodes
Laser Wavelength 630 – 680 nm visible
Laser Power ≤1 mW CLASS 2 LASER PRODUCT
Working Range 33 (10m)
Accuracy ±1/4” @ 33 (±6 mm @ 10m)
Power Source 2 AA (1.5V) size batteries (3V DC)
Operating Temperature 14°F to 104°F (-10°C to 40°C)
Storage Temperature -5°F to 158°F (-20°C to 70°C)
IP Rating IP50
16
ES
Contenido
• Información de láser
• Seguridad de usuario
• Seguridad de batería
• Instalación de Baterías AA
• Encendido del láser
• Vericación de precisión de Láser
• Uso del Láser
• Mantenimiento
• Solución de problemas
• Servicio y Reparaciones
• Especicaciones
Información de láser
El láser STHT77611 es un producto láser de clase
2. Los láseres son herramientas láser de nivelación
automática que se pueden usar para proyectos de
alineación horizontal (nivel) y vertical (caída).
Seguridad del usuario
Guías de Seguridad
Las siguientes deniciones describen el nivel de
severidad para cada palabra de señal. Por favor lea el
manual y ponga atención a estos símbolos.
PELIGRO: Indica una situación
inminentemente peligrosa que, si no se evita,
resultará en la muerte o lesiones serias.
ADVERTENCIA: Indica una situación
potencialmente peligrosa que, si no se evita,
podría resultar en la muerte o lesiones serias.
PRECAUCIÓN: Indica una situación
potencialmente peligrosa que, si no se evita,
puede resultar en lesiones menores
o moderadas.
AVISO: Indica una práctica no relacionada con
lesiones personales que, si no se evita, puede
resultar en daño a la propiedad.
Si tiene cualquier pregunta o comentario sobre
esta o cualquier herramienta STANLEY
®
, visite
www.STANLEYTOOLS.com.
ADVERTENCIA:
Lea y entienda todas las instrucciones.
La falla en seguir las advertencias
e instrucciones en este manual puede resultar
en lesiones personales serias.
CONSERVE ESTAS INSTRUCCIONES
ADVERTENCIA:
Exposición a Radiación Láser. No
desensamble o modique el nivel láser. No
hay partes a las que se pueda dar servicio
en el interior. Podría resultar en lesiones
serias a los ojos.
ADVERTENCIA:
Radiación Peligrosa. El uso de controles
o ajustes, o la realización de procedimientos,
diferentes a los especicados en el presente
pueden resultar en exposición a radiación
peligrosa.
La etiqueta en su láser puede incluir los siguientes
símbolos.
Símbolo Signicado
V Voltios
mW Miliwatts
Advertencia de Láser
nm Longitud de onda en nanómetros
2 Láser Clase 2
17
ES
Etiquetas de advertencia
Para su conveniencia y seguridad, las siguientes
etiquetas se encuentran en su láser.
ADVERTENCIA: Para reducir el riesgo
de lesiones, el usuario debe leer el
manual de instrucciones.
ADVERTENCIA: RADIACIÓN LÁSER.
NO MIRE FIJAMENTE EL RAYO.
Producto Láser Clase 2.
www.STANLEYTOOLS.com
Complies with 21 CFR 1040.10 and 1040.11
except for deviations pursuant to Laser Notice
No. 50, dated June 24, 2007.
TYPE 1: 3VDC
Made in China
STHT77611
Si el equipo se utiliza de una manera no
especicada por el fabricante, la protección
proporcionada por el equipo puede ser
deteriorada.
No opere el láser en atmósferas explosivas, tal
como en la presencia de líquidos, gases o polvo
inamables. Esta herramienta puede crear chispas
que pueden encender el polvo o vapores.
Guarde un láser que no esté en uso fuera del
alcance de los niños y otras personas sin
capacitación. Los láseres son peligrosos en las
manos de usuarios sin capacitación.
El servicio de la herramienta se DEBE realizar
por personal de reparación calicado. El servicio
o mantenimiento por personal no calicado puede
resultar en lesiones. Para localizar su centro
de servicio Stanley más cercano, visite www.
STANLEYTOOLS.com.
No use herramientas ópticas tales como un
telescopio o tránsito para ver el rayo láser.
Podría resultar en lesiones serias a los ojos.
No coloque el láser en una posición que
pueda causar que alguien observe intencional
o inadvertidamente el rayo láser. Podría resultar
en lesiones serias a los ojos.
No coloque el láser cerca de una supercie
reejante que pueda reejar el rayo láser a los
ojos de alguien. Podría resultar en lesiones serias
a los ojos.
Apague el láser cuando no esté en uso. Dejar
el láser encendido incrementa el riesgo de ver al
rayo láser.
No modique el láser en ninguna manera.
Modicar la herramienta puede resultar en
exposición peligrosa a la radiación de láser.
No opere el láser alrededor de niños ni permita
que niños operen el láser. Puede resultar en
lesiones serias a los ojos.
No retire o elimine las etiquetas de advertencia.
Si se retiran las etiquetas, el usuario u otros pueden
exponerse inadvertidamente a la radiación.
Coloque el láser rmemente sobre una supercie
nivelada. Si el láser cae, podría resultar en daño al
láser o lesiones serias.
Seguridad Personal
Permanezca alerta, observe lo que está haciendo,
y use el sentido común cuando opere el láser.
No use el láser cuando esté cansado o bajo la
inuencia de drogas, alcohol, o medicamentos. Un
momento de falta de atención mientras opera el
láser puede resultar en lesiones personales serias.
Use equipo de protección personal. Siempre use
protección para los ojos. Dependiendo de las
condiciones de trabajo, usar equipo de protección tal
como una máscara de polvo, zapatos de seguridad
anti-deslizantes, casco, y protección auditiva
reducirá las lesiones personales.
18
ES
Uso y Cuidado de la Herramienta
No use el láser si el interruptor de Bloqueo de
energía/Transporte no enciende o apaga el láser.
Cualquier herramienta que no se pueda controlar
con el interruptor es peligrosa y se debe reparar.
Siga las instrucciones en la sección de
Mantenimiento de este manual. El uso de partes no
autorizadas o la falla en seguir las instrucciones de
Mantenimiento puede crear un riesgo de descarga
eléctrica o lesiones.
Declaración de FCC
Este equipo ha sido probado y cumple con los límites
para dispositivos digitales de clase B, de conformidad
con la parte 15 de las normas FCC. Estos límites
han sido diseñados para proporcionar una protección
razonable contra las interferencias nocivas en
instalaciones residenciales. Este equipo genera,
usa e irradia energía de radiofrecuencia y, si no se
instala y se usa de acuerdo con las instrucciones,
puede causar interferencia perjudicial para las
radiocomunicaciones. No obstante, no existe ninguna
garantía de que no se producirá interferencia en
una instalación determinada. Si este equipo causa
interferencias perjudiciales para la recepción de radio
o televisión, que puede determinarse al encender
y apagar el equipo, el usuario puede tratar de corregir
la interferencia tomando una o varias de las siguientes
medidas:
- Reorientar o reubicar la antena receptora.
- Aumentar la distancia entre el equipo y el receptor.
- Conectar el equipo en un tomacoriente de otro
circuito diferente (no el circuito al que está conectado
el receptor).
- Consulte al vendedor o a un técnico experto en radio/
TV para solicitar su ayuda.
Seguridad de la batería
ADVERTENCIA:
Las baterías pueden explotar, o tener
fugas, y pueden causar lesiones
personales o incendios. Para reducir este
riesgo:
Siga todas las instrucciones y advertencias
colocadas en las etiquetas y el paquete de las
baterías.
Siempre inserte las baterías correctamente respecto
a la polaridad (+ y –), como está marcado en la
batería y el equipo.
No ponga en corto las terminales de la batería.
No cargue las baterías desechables.
No mezcle baterías nuevas y viejas. Cambie todas
las baterías al mismo tiempo con baterías nuevas
del mismo tipo y marca.
Retire las baterías descargadas de inmediato
y deséchelas conforme a los códigos locales.
No deseche las baterías en fuego.
Mantenga las baterías fuera del alcance de los
niños.
Retire las baterías cuando el dispositivo no esté
en uso.
Instalación de Baterías AA
Cargar las baterías AA nuevas en el láser STHT77611.
1.
Voltee el láser.
2.
En la parte inferior del láser, levante el seguro
para abrir la cubierta del compartimiento de
baterías (Figura
B
1
).
3.
Inserte dos baterías AA de marca de alta calidad
nuevas, asegurándose de colocar los extremos -
y + de cada batería como se indica en el interior
del compartimiento de baterías (Figura
B
2
).
19
ES
4.
Cierre la cubierta del compartimiento de baterías
hasta que se conecte en su lugar (Figura
B
3
).
Cuando el láser no esté en uso, mantenga el
interruptor de Bloqueo de energía/Transporte en
la posición central (Apagado) (Figura
A
2
) para
ahorrar energía de las baterías.
Encendido del láser
1.
Coloque el láser sobre una superficie lisa, plana
y nivelada, con el láser viendo directo al frente
hacia la pared opuesta.
2.
Encienda el láser para mostrar los rayos láser
horizontal y vertical. Ya sea:
• Mueva el interruptor de Bloqueo de energía/
Transporte a la izquierda para mantener el
péndulo bloqueado y mostrar los rayos cruzados
en modo manual (Figura
A
1
).
• Mueva el interruptor de Bloqueo de energía/
Transporte a la derecha para desbloquear el
péndulo y mostrar los rayos cruzados en modo
de nivelación automática (Figura
A
3
).
3.
Revise los rayos láser horizontal y vertical.
• Si el láser está inclinado demasiado de forma
que no se pueda nivelar automáticamente
(> 4°), o el láser no está nivelado en modo
manual, los rayos láser parpadearán.
• Si los rayos láser parpadean, el láser no está
nivelado (o con caída) y NO SE DEBE USAR
para determinar o realizar el nivel o caída.
Intente reubicar el láser sobre una superficie
nivelada.
4.
Si CUALQUIERA de las siguientes declaraciones
es VERDADERA, continúe con las instrucciones
para Vericación de precisión de láser ANTES
DE USAR EL LÁSER para un proyecto.
• Ésta es la primera vez que usa el láser (en
caso de que el láser haya estado expuesto
a temperaturas extremas).
• No se ha verificado la precisión del láser por
un tiempo.
• Se puede haber dejado caer el láser.
Vericación de precisión de
Láser
Las herramientas láser están selladas y calibradas en
la fábrica. Se recomienda que realice una vericación
de precisión antes de usar el láser por primera vez
(en caso que el láser se haya expuesto a temperaturas
extremas) y después regularmente para garantizar la
precisión de su trabajo. Cuando realice cualquiera de
las vericaciones de precisión indicadas en este
manual, siga estas guías:
Use el área/distancia mayor posible, más cerca
a la distancia de operación. Mientras mayor sea
el área/distancia, más fácil será medir la precisión
del láser.
Coloque el láser sobre una supercie lisa,
plana y estable que esté nivelada en ambas
direcciones.
Marque el centro del rayo láser.
Rayo Horizontal - Dirección de Exploración
Vericar la calibración de exploración horizontal del
láser requiere dos paredes a por lo menos 30′ (9m)
de distancia. Es importante realizar una vericación
de calibración utilizando una distancia no más corta
que la distancia de las aplicaciones para las que se
utilizará la herramienta.
1.
Coloque la parte trasera del láser contra una
pared y viendo al frente hacia la pared opuesta.
2.
Mueva el interruptor de Bloqueo de energía/
Transporte a la derecha (Figura
A
3
) para
encender el láser en modo de nivelación
automática y mostrar los rayos láser horizontal
y vertical.
20
ES
3.
Gire el láser 45º en sentido contrario a las
manecillas del reloj de forma que el extremo
derecho de la línea láser se muestre en la pared
(Figura
D
1
).
4.
Marque
a
en el centro del rayo sobre la pared.
5.
Gire el láser 90º en sentido de las manecillas del
reloj de forma que el extremo izquierdo de la línea
láser se muestre cerca
a
(Figura
D
2
).
6.
Marque
b
en el centro del rayo sobre la pared.
7.
Mida la distancia vertical entre
a
y
b
.
8.
Si su medición es mayor a la Distancia
permisible entre
a
y
b
para la Distancia entre
paredes correspondiente en la siguiente tabla, se
debe dar servicio al láser en un centro de servicio
autorizado.
Distancia entre
Paredes
Distancia Permisible
Entre
a
y
b
30 (9m) 7/16” (11.0mm)
40 (12m) 9/16” (14.4mm)
50 (15m) 23/32” (18.0mm)
Rayo Horizontal - Dirección de Inclinación
Vericar la calibración de inclinación horizontal del
láser requiere una sola pared de por lo menos 30
(9m) de largo. Es importante realizar una vericación
de calibración utilizando una distancia no más corta
que la distancia de las aplicaciones para las que se
utilizará la herramienta.
1.
Coloque el láser contra el extremo de la pared
(Figura
E
1
).
2.
Mueva el interruptor de Bloqueo de energía/
Transporte a la derecha (Figura
A
3
) para
encender el láser en modo de nivelación automática
y mostrar los rayos láser horizontal y vertical.
3.
Por lo menos a 30(9m) a lo largo del rayo láser,
marque
a
y
b
.
4.
Mueva el láser al extremo opuesto de la pared
(Figura
E
2
).
5.
Coloque el láser hacia el primer extremo de la
misma pared y paralelo a la pared adyacente.
6.
Ajuste la altura del láser de forma que el centro
del rayo esté alineado con
b
.
7.
Directamente arriba o abajo de
a
, marque
c
a lo
largo del rayo láser (Figura
E
3
).
8.
Mida la distancia entre
a
y
c
.
9.
Si su medición es mayor que la Distancia
permisible entre
a
y
c
para la Distancia
correspondiente entre
a
y
b
en la siguiente
tabla, se debe dar servicio al láser en un centro
de servicio autorizado.
Distancia Entre
a
y
b
Distancia Permisible
Entre
a
y
c
30 (9m) 7/16” (11.0mm)
40 (12m) 9/16” (14.4mm)
50 (15m) 23/32” (18mm)
Rayo Vertical - Caída
Vericar la caída vertical (caída) del láser se puede
realizar con mayor precisión cuando hay una cantidad
substancial de altura vertical disponible, idealmente 30
(9m), con una persona en el piso colocando el láser
y otra persona cerca del techo para marcar la posición
del láser. Es importante realizar una vericación de
calibración utilizando una distancia no más corta que la
distancia de las aplicaciones para las que se utilizará la
herramienta.
1.
En el piso entre dos paredes, marque una línea
de 5 pies (1.5 m) que sea paralela a la pared
adyacente (Figura
F
1
).
2.
Mueva el interruptor de Bloqueo de energía/
Transporte a la derecha (Figura
A
3
) para
encender el láser en modo de nivelación
automática y mostrar los rayos láser horizontal
y vertical.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Stanley STHT77611 Manuel utilisateur

Taper
Manuel utilisateur