HomComfort HCPHTTM Manuel utilisateur

Taper
Manuel utilisateur
Model: HCPHTTM
853162---0802H
United States Stove Company
227 Industrial Park Road South Pittsburg, TN 37380 www.usstove.com
FOR TECHNICAL ASSISTANCE: PHONE: (800) 750-2723
2
WARNING:
The powder coating paint process has become the
most common application in the outdoor furniture
category. Unfortunately powder coating is extremely
sensitive to humidity and moisture. A simple process to
protect your furniture, especially at surfaces is to apply
a simple coat of good quality car wax prior to using. If
this process is done every few months it will protect your
furniture for years to come.
WARNING:
Improper installation, adjustment, alteration, services
or maintenance can cause injury, death, or property
damage. Read the installation, operating and
maintenance instructions thoroughly before installing or
servicing this equipment.
DANGER:
CARBON MONOXIDE HAZARD
This appliance can produce carbon monoxide which
has no odor. Using it in an enclosed space can kill you.
Never use this appliance in a enclosed space such as a
camper, tent, or home.
WARNING:
FOR OUTDOOR USE ONLY
Cylinders to be used must be constructed and marked
in accordance with US DOT specications. Storage
indoors is permissible only if the cylinder is removed.
CAUTION:
The minimum inlet gas supply pressure for the purpose
of input adjustment is 8 inches water column. The
maximum inlet gas supply pressure is 13 inches water
column. The gas manifold supply pressure must be
regulated at 11 inches water column utilizing an
approved regulator.
Note: Use a 1 lb. LPG tank (not included), the CSA
regulator is provided.
Rate 11,000 BTU/hr
Gas Propane, LP
Gas cylinder 16.4 oz
Orice 1.0 mm
Manifold Pressure 11” W.C
Supply Pressure Max. 150PSI, Min. 5PSI
Do not use the heater in an explosive atmosphere.
Keep the heater away from areas where gasoline or other ammable liquids or vapors are stored.
Prior to use, check for damaged parts such as hoses, regulators, pilot, or burner.
Disconnect the LPG bottle before moving the heater.
Do not attempt to alter the unit in any manner. Example: Using the heater without the top canopy reector
or radiant screen.
Do not shorten the burner post assembly.
The appliance shall not be used in basements or below ground level.
It must always be placed on a solid and level surface.
Always ensure there is ample fresh air ventilation.
For outdoor use only.
Maintain at least 50’’ top clearance to combustible materials surfaces.
Never replace or substitute the regulator with any regulator other than the factory suggested replacement.
Do not clean the heater with cleaners that are combustible or corrosive.
Do not paint the radiant screen, control panel or top canopy. Leak tests should be done with a soapy
solution. NEVER USE AN OPEN FLAME TO CHECK FOR LEAKS.
The LP gas cylinder should be turned off when the heater is not in use.
At least once a year, the unit should be inspected for the presence of spiders, spider webs or other insects;
check the heater immediately if any of the following exist:
1. The smell of gas in conjunction with extreme yellow colored tips of the burner ames.
2. The heater does not reach temperature
3. The burner makes popping noises during use ( slight popping noises is normal when the turner is extinguished
after using)
a. Children and adults should be aware of the hazards of high surface temperature and shall stay away
to avoid burns or clothing ignition.
b. Young children should be carefully supervised when they are in the area of the heater.
c. Clothing or other ammable material should not be hung from the heater or placed on or near the
heater.
WARNING: This appliance must only be used
outdoors. Using this product in an enclosed area may
cause injury, death, or property damage. Read the
instructions before use. This appliance must be installed
in accordance with such regulations as are enforced.
Precautions
3
d. Any guard or other protective device removed for servicing the heater must be replaced prior to
operation the heater
e. Installation and repair should be done by a qualied service person. The heater should be inspected
before use and cleaning may be required at least once a year or as necessary. It is imperative that
control compartment burner and circulation air passageways of the heater be kept clean.
Keep the appliance area clear of combustible materials such as gasoline and other ammable vapors and
liquids.
DO NOT obstruct the ow of combustion and ventilation air reector.
Keep the ventilation opening of the cylinder enclosure clear of any obstructions.
NOTE: PLEASE READ THE FOLLOWING SAFETY RULES.
The valve outlet must be maintained in good condition. All gas connections should be checked for leaks utilizing
a soap solution. Never use a ame to test for leaks. A leak test should be performed with soapy water whenever
connecting a new cylinder. Never use a match to test for leaks. If disassembly is required, a leak test should be
performed with soapy water upon reassembly. The heater is designed to operate with a standard 1 lbs. propane
cylinder with approved cylinder connection. The gas manifold supply pressure must be regulated at 11 inches
water column utilizing an approved regulator. The minimum inlet gas supply pressure for the purpose of input
adjustment is 8 inches water column. The maximum inlet gas supply pressure 13 inches water column.
1. The cylinder supply system must be arranged for vapor withdrawal.
2. The cylinder used must include a collar to protect the cylinder valve only cylinders marked “propane” must
be used.
WARNING:
Do not store a spare LP-gas cylinder under or
near this appliance.
Never ll the cylinder beyond 80% full.
WARNING:
Save these instructions! Retain in a safe place for
future reference.
WARNING:
LP-gas supply cylinder to be used must be:
1. Constructed and marked in accordance with
the specications for LP-gas cylinders of the
U.S. Department of Transportation (DOT); or
the standard for cylinders , spheres, and tubes
for transportation of dangerous goods and
commission, CAN/CSA-B339;
2. Provided with a listed overlling prevention
device;
3. Provided with a cylinder connection device
compatible with the connection for the
appliance.
4
Assembly
WARNING:
Proper assembly is the responsibility of the installer. Place the heater in a well-ventilated space and do not place in
a building, garage, or any other enclosed area.
An appliance must be installed with shelter no more inclusive than:
1. With walls on all sides, but with no overhead cover.
2. Within a partial enclosure which includes an overhead cover and no more than two side walls. These side
walls may be parallel, as in a breezeway, or at right angles to each other.
3. Within a partial enclosure which includes an overhead cover and three side walls, as long as 30% or more of
the horizontal periphery of the enclosure of permanently open.
STEP 1
Use (4) four M6 X 15mm bolts to x the tank housing
to the base & cast iron. Tighten the bolts as shown
above.
STEP 2
Put the burner on the tank housing then x them with
(4) four 3/16” bolts.
STEP 3
Fix the regulator to the tank housing with the M5 X
10mm bolt & M5 nut.
STEP 4
Fix (3) three pins of 60mm length to the emitter screen
with (3) three ange nuts, then tighten them.
5
STEP 5
Put the emitter screen on the burner. Use (4) four 3/16”
bolts to connect the emitter screen to the burner.
Tighten the bolts.
STEP 6
Put the guard on the burner through the emitter
screen. Put the ends of the guard into the holes of the
burner.
STEP 7
Put (3) three washers on each pins of the 60mm
length.
STEP 8
Put the reector through the pins and on the washers.
STEP 9
Fasten the reector with (3) three M6 castle nuts.
6
WARNING:
The cylinder uses must include a collar to protect the cylinder valve. Do not store a spare LP-gas cylinder under or
near this appliance. Never ll the cylinder beyond 80% full.
STEP 10
Turn off the control knob of the burner. Fix the 1 lbs. gas
tank (not included) to the regulator (rotate the gas
tank clockwise toward the regulator until tighten it).
STEP 11
Close the door plate and lock it with the handle
(rotate the handle 90 degrees)
7
WARNING:
DO NOT attempt to operate the heater until you have
read and understood all precautions. Failure to do so
can result in serious personal injury, death, and property
damage.
WARNING:
FOR YOUR SAFETY
DO NOT touch or move heater for at least 45 minutes
after use. Allow emitter and dome to cool before
touching.
WARNING:
FOR YOU SAFETY
If at any time you are unable to light burner and smell
gas, wait 5 minutes to allow gas to dissipate before
attempting to light heater. If after 1 minute, you are
unable to light burner, wait 5 minutes and allow
ammable vapors to dissipate before attempting to
light heater again.
BEFORE TURNING GAS SUPPLY ON
Your heater was designed and approved for OUTDOOR USE ONLY. Do Not use it inside a building, or any other
enclosed area. Make sure surrounding areas are free of combustible materials, gasoline, and other ammable
vapors or liquids. Ensure that there is no obstruction to air ventilation. Be sure all gas connections are tight and
there are no leaks. Be sure that access panels are clear of debris. Be sure any component removed during
assembly or servicing is replaced and fastened prior to starting.
BEFORE LIGHTING
Heater should be thoroughly inspected before each use, and by a qualied service person at least annually.
If relighting a hot heater, always wait at least 5mins. This heater is tested for quality assurance. Ignition attempts
should succeed 8 out of 10 attempts.
LIGHTING INSTRUCTIONS
1. Turn the control knob to “OFF” position
2. Open base assembly door
3. Turn the gas supply on by connecting the propane cylinder to the regulator inlet. Check for leaks by applying
soap solution to cylinder and regulator connection.
4. Push in gas control knobs lightly and turn counterclockwise to “ON” this will light the burner. If needed, keep
depressing and turn control knob counterclockwise until the burner lights.
5. Keep the control knob depressed for at least 30 seconds after lighting the burner. After 30 seconds release
the control knob.
6. If burner does not stay lit, repeat steps 4 to 5
7. When burner is lit, turn gas control knob counterclockwise to desired higher setting.
8. Close the base assembly door.
Note: The ame pattern at the emitter grid should be visually checked whenever heater is operated. Normally
the burner ame is blue, but a little yellow ame is acceptable. If ames extend beyond the emitter grid or there
are black spots that have accumulated on the emitter grid or reector, immediately turn off the heater. The
heater should not be operated again until it has been serviced and repaired by a qualied gas technician.
Operation
P
I
L
O
T
H
I
L
O
O
F
F
P
I
L
O
T
H
I
L
O
O
F
F
8
If you experience any ignition problem, turn off the heater and gas supply, and consult the troubleshooting
section of this manual.
Note: The burner may be noisy when initially turned on. To eliminate excessive noise from the burner, turn the
control knob to the “LOW” position, then turn the knob to the level of heat desired.
WHEN HEAR IS ON
Emitter screen will become bright red due to intense heat. The burner will display tongues of blue ame. These
ames should NOT be yellow or produce thick black smoke. This indicates an obstruction of airow through the
burners.
OPERATION PRESSURE CHECKED
If the ame is very small, this is because the supply pressure is not enough to light.
1. Turn the control knob to the “OFF” position.
2. Wait ve minutes before attempting to relight the pilot.
3. Repeat steps beginning with step 2 in the lighting instruction section of this manual.
BEFORE LEAVING
1. Turn the control knob to the “OFF” position.
2. Never leave the patio heater unattended while in use.
SHUT DOWN INSTRUCTIONS
1. Push in and turn control knob clockwise to “OFF” position.
2. Disconnect the LP cylinder when heater is not in use.
Note: after use, some discoloration of the emitter screen is normal.
THE EVENT OF GAS LEAKAGE
1. Turn the control knob to “OFF” position
2. Wait 5 minutes to allow gas to dissipate
3. If odor continues, immediately call the gas supplier.
CAUTION:
Avoid inhaling fumes emitted form the heater’s rst use. Smoke and odor from the burning of oils used in
manufacturing will appear. Both smoke and odor will dissipate after approximately 30 minutes. The heater
should NOT produce thick black smoke.
WARNING:
Heater will be hot after use; handle with extreme care.
BE CAREFUL! WHEN CERTAIN MATERIALS OR ITEMS ARE LEFT
ABOVE, BESIDE OR UNDER THIS HEATER WHILE IN USE. THEY
WILL BE SUBJECT TO RADIANT HEAT AND COULD BE SERIOUSLY
DAMAGED.
This heater is primarily used for the heating of outdoor patios,
decks, spas, pool and open working areas. Always make sure
that adequate fresh air ventilation is provided. Follow the spacing
tolerances as shown. The minimum clearances must be maintained
at all times. The installation must conform to local codes or in the
absence of local codes, with the standard for the storage and
handling of liquid petroleum gases, ANS/NFPA 58-1986. Or most
recent addition. For Canada, with the current CAN1-B149. The
heater must be placed on level rm ground. Never operate in an
explosive atmosphere. Keep away from areas where gasoline or
other ammable liquids or vapors are stored or used.
9
CHECK YOUR HOSE ASSEMBLY
The installation shall only be carried out by competent persons and be in accordance with the relevant codes
of practice.
Prior to use, check for damaged parts such as regulator, pilot or burner. Never replace or substitute the regulator
with any regulator other than the factory suggested replacement.
CHECK YOU FLAME
The ame pattern at the emitter screen should be visually checked whenever heater is operated. Normally the
burner ame is blue, but little yellow ame is acceptable. If ame extend beyond the emitter grid or there are
black spots that have accumulated on the emitter grid or reector, immediately turn off the patio heater. The
heater should not be operated again until it has been serviced and repaired by a qualied gas technician.
CLEAN
To enjoy years of outstanding performance from your heater make sure you perform the following maintenance
activities on a regular basis:
1. Keep exterior surfaces clean:
Use warm soapy water for cleaning. Never use ammable or corrosive cleaning agents.
• While washing your unit, be sure to keep the area around the burner and pilot assembly dry at all times. If
the gas control is exposed to water in any way: do not try to use it. It must be replaced.
2. Air ow must be unobstructed. Keep controls, burner, and circulating air passageways clean. Signs of possible
blockage include:
Gas odor with extreme yellow tipping of ame.
• Heater does not reach the desired temperature.
• Heater glow is excessively uneven.
• Heater makes popping noises.
3. Spiders and insects can nest in burner or orices. This dangerous condition can damage heater and render
it unsafe for use. Clean burner holes by using a heavy-duty pipe cleaner. Compressed air may help clear
away smaller particles.
4. Carbon deposits may create a re hazard. Clean dome and emitter screen with warm soapy water if any
carbon deposits develop.
WARNING:
This appliance requires regulator. Check with your gas supplier and or products supplier.
WARNING:
FOR YOUR SAFETY
DO NOT touch or move heater for at least 45 minutes after use. Allow all burner elements to cool before
touching.
NOTE: In a salt-air environment (such as near an ocean) corrosion occurs more quickly than normal.
Frequently check for corroded areas and repair them promptly.
Maintenance
10
BETWEEN USES
Turn the control knob to the “OFF” position.
Open the door and disconnect the cylinder.
Store the heater upright in an area sheltered from direct contact with inclement weather (such as rain, sleet,
hail, snow, dust and debris).
To protect the exterior surfaces and help prevent debris in the air passages, cover the heater.
DURING PERIODS OF EXTENDED INACTIVITY OR WHEN TRANSPORTING
Turn the control knob to the “OFF” position.
Disconnect the LP cylinder and move to a secure well-ventilated location outdoors. Do NOT store in a
location that will exceed 125 degrees F.
The propane cylinder must be stored outdoors in a well-ventilated area. It must be out of reach of children,
and not in a building, garage, or any other enclosed area.
Store heater upright in an area sheltered from direct contact with inclement weather (such as rain, sleet,
hail, snow, and debris). If desired, cover the heater to protect surfaces and to help prevent debris in air
passages.
NOTE: Wait until the heater is cool before covering
Storage
Troubleshooting
PROBLEM PROBABLE CAUSE SOLUTION
Pilot will not light
Gas valve may be off Turn the gas valve on
Fuel tank empty Rell the LP gas tank
Orice blocked Clean or replace orice
Air in the supply system Purge air from lines
Loose connection Check all ttings
Pilot will not stay on
Debris around pilot Clean dirty area
Loose connection Tighten connection
Thermocouple is bad Replace thermocouple
Gas leak in line Check connection
Lack of fuel pressure Fuel tank is near empty
Burner will not light
Pressure is low Fuel tank is near empty
Orice blocked Remove, clean, and replace
Control valve is not on Turn valve to the “ON” position
Thermocouple is bad Replace the thermocouple
Pilot light assembly bent or not in correct location Place pilot in proper position and retry
11
1
2
4
5
3
Parts
Key Part No. Description Qty.
1 892958 Reector 1
2 892959 Emitter Screen 1
3 892960 Guard 1
4 81299 Burner Assembly 1
5 81300 Regulator 1
ATTENTION: In order to maintain warranty, components must be replaced using original manufacturers parts
purchased through your dealer or directly from the appliance manufacturer. Use of third party components
will void the warranty.
For technical assistance: phone: (800) 750-2723
12
Notes
13
Service 01 Date:________________________
Engineer Name:_____________________________________
Company:__________________________________________
Telephone No.:______________________________________
Unit Inspected:
Check Gas Lines For Wear Or Leaks
Check Integrity Of Orifice And Gas Ports
Items Replaced:____________________________________
It is recommended that this unit is serviced regularly and that the appropriate Service Interval Record is completed.
Service Provider:
Before completing the appropriate Service Record below, please ensure you have carried out the service as described in the
manufacturer’s instructions. Always use the manufacturer's specified spare part when replacement is necessary.
License No.:________________________________________
Service 03 Date:________________________
Engineer Name:_____________________________________
Company:__________________________________________
Telephone No.:______________________________________
Unit Inspected:
Check Gas Lines For Wear Or Leaks
Check Integrity Of Orifice And Gas Ports
Items Replaced:____________________________________
License No.:________________________________________
Service 05 Date:________________________
Engineer Name:_____________________________________
Company:__________________________________________
Telephone No.:______________________________________
Unit Inspected:
Check Gas Lines For Wear Or Leaks
Check Integrity Of Orifice And Gas Ports
Items Replaced:____________________________________
License No.:________________________________________
Service 02 Date:________________________
Engineer Name:_____________________________________
Company:__________________________________________
Telephone No.:______________________________________
Unit Inspected:
Check Gas Lines For Wear Or Leaks
Check Integrity Of Orifice And Gas Ports
Items Replaced:____________________________________
License No.:________________________________________
Service 04 Date:________________________
Engineer Name:_____________________________________
Company:__________________________________________
Telephone No.:______________________________________
Unit Inspected:
Check Gas Lines For Wear Or Leaks
Check Integrity Of Orifice And Gas Ports
Items Replaced:____________________________________
License No.:________________________________________
Service 06 Date:________________________
Engineer Name:_____________________________________
Company:__________________________________________
Telephone No.:______________________________________
Unit Inspected:
Check Gas Lines For Wear Or Leaks
Check Integrity Of Orifice And Gas Ports
Items Replaced:____________________________________
License No.:________________________________________
Service Record
Distributed By:
United States Stove Company
227 Industrial Park Rd
South Pittsburg, TN 37380
www.usstove.com
(800) 750-2723
1 year limited warranty - Customers in the Continental US
All components are warranted for a period of 1 year after date of purchase by the original owner against defects
in materials and workmanship under normal use. This warranty does not cover normal wear and weathering,
assembly and \or maintenance or use in commercial application if model is not designated as a commercial
mode. At USSC’s sole discretion, products under warranty will be repaired and \or replaced at no charge to
the customer. Any returns sent back to USSC must be sent via prepaid freight and in the original retail packaging.
For warranty service contact USSC at the address, Phone number or web site listed in this owner’s manual. Be sure
to have your sales receipt, date of purchase and catalogue/model number available when calling. All warranty
service will be coordinated by the USSC service center.
This warranty is extended only to the original purchaser. Proof of purchase will be required before warranty
service is rendered. The sales receipt is the only valid proof of purchase. This warranty only covers failures due
to defects in materials or workmanship which occur during normal use. Failures and\or damage which result
from accident, negligence, misuse, abuse, neglect, mishandling alteration or modication, failure to maintain,
improper assembly or maintenance, service by unauthorized agency or use of unauthorized components or
damage that is attributable to acts of god are not covered.
***THERE ARE NO EXPRESS WARRANTIES EXCEPT AS LISTED ABOVE***
***PURCHASER ASSUMES ALL RISK IN THE ASSEMBLY AND OPERATION OF THIS UNIT***
***FAILURE TO FOLLOW WARNINGS AND OPERATIONAL INSTRUCTIONS CONTAINED IN THIS MANUAL CAN RESULT
IN SEVERE PROPERTY DAMAGE AND\OR PERSONAL INJURY***
IN NO EVENT WILL USSC OR ITS DIRECTORS, OFFICERS OR AGENTS BE LIABLE TO THE PURCHASER OR ANY THIRD PARTY,
WHETHER IN CONTRACT, IN TORT, OR ON ANY OTHER BASIS , FOR ANY INDIRECT, SPECIAL, PUNITIVE, EXEMPLARY,
CONSEQUENTIAL, OR INCIDENTAL LOSS, COST, OR DAMAGE ARISING OUT OF OR IN CONNECTION WITH THE SALE,
MAINTENANCE, USE, OR INABILITY TO USE THE PRODUCT, EVEN IF USSC OR ITS DIRECTORS, OFFICERS OR AGENTS
HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH LOSSES, COSTS OR DAMAGES, OR IF SUCH LOSSES, COSTS, OR
DAMAGES ARE FORESEEABLE. IN NO EVENT WILL USSC, OR ITS OFFICER, DIRECTORS, OR AGENTS BE LIABLE FOR ANY
DIRECT LOSSES, COSTS OR DAMAGES THAT EXCEED THE PURCHASE PRICE OF THE PRODUCT.
SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL
DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO THE PURCHASER.;
This limited warranty gives you specic legal rights and you may also have other rights which vary from jurisdiction
to jurisdiction. The provisions of the United Nations Convention on Contracts for the sales of goods shall not apply
to this limited warranty or the sale of products covered by this limited warranty.
***IMPORTANT NOTICE***
-DO NOT return to place of purchase-
For customer service and warranty issues contact customer service
14
Distribué par :
United States Stove Company
227 Industrial Park Rd
South Pittsburg, TN 37380
www.usstove.com
(800) 750-2723
Garantie limitée d'un an - Clients dans la zone continentale des États-Unis
Tous les composants sont garantis pendant 1 an après la date d’achat par le propriétaire original contre les
défauts des matériaux et de fabrication sous une utilisation normale. Cette garantie ne couvre pas l’usure
normale, le vieillissement naturel, l’assemblage et/ou l’entretien ou l’utilisation commerciale si le modèle n’est
pas désigné comme un modèle commercial. À la seule discrétion de l'USSC, les produits sous garantie seront
réparés et / ou remplacés sans frais pour le client. Tous les retours à USSC doivent être effectués par transport
prépayé et dans l’emballage original.
Pour un service sur garantie, contactez USSC à l’adresse, le numéro de téléphone ou le site Web inscrit dans le
manuel du propriétaire. Assurez-vous d’avoir en main votre reçu de vente, la date de l’achat et le numéro de
catalogue/modèle lors de votre appel. Tout service sur garantie sera coordonné par le centre de service USSC.
Cette garantie n’est destinée qu’à l’acheteur original. La preuve d’achat sera requise avant que le service sous
garantie ne soit effectué. Le reçu de vente est la seule preuve d’achat valide. Cette garantie ne couvre que
les défaillances en raison des défauts des matériaux ou de la fabrication survenant pendant un usage normal.
Les défaillances et/ou dommages résultant d’un accident, une négligence, une mauvaise utilisation, l’abus, la
négligence, une altération ou des modications sans précautions, le défaut d’entretenir, un mauvais assemblage
ou entretien, une réparation par une agence non autorisée ou l’utilisation de composants non autorisés ou des
dommages attribuables à une force majeur, ne sont pas couverts.
***IL N’Y A AUCUNE GARANTIE EXPRESSE, SAUF COMME IL EST INDIQUÉ CI-DESSOUS***
***L'ACHETEUR ASSUME TOUS LES RISQUES DE L'ASSEMBLAGE ET DU FONCTIONNEMENT DE CETTE UNITÉ***
***NE PAS RESPECTER LES AVERTISSEMENTS ET DIRECTIVES DE FONCTIONNEMENT CONTENUES DANS CE MANUEL
PEUT CAUSER DE SÉVÈRES DOMMAGES À LA PROPRIÉTÉ ET/OU CAUSER DES BLESSURES PERSONNELLES***
EN AUCUN CAS, USSC OU SES DIRIGEANTS, OFFICIERS OU AGENTS, NE SERONT RESPONSABLES DEVANT L’ACHETEUR
OU TOUT AUTRE TIERS, S’IL SURVENAIT DANS LE CONTRAT, UN ACTE DÉLICTUEL, OU SURVENAIT SUR TOUTE AUTRE
BASE, DES PERTES, DES COÛTS OU DES DOMMAGES INDIRECTS, SPÉCIAUX, PUNITIFS, EXEMPLAIRES, CONSÉCUTIFS,
OU FORTUITS, OU RELATIFS À LA VENTE, L’ENTRETIEN, L’UTILISATION, OU L’INCAPACITÉ À UTILISER LE PRODUIT, MÊME
SI USSC, OU SES DIRIGEANTS, OFFICIERS OU AGENTS SONT PRÉVENUS DE LA POSSIBILITÉ DE CES PERTES, COÛTS OU
DOMMAGES, OU SI CES PERTES, COÛTS OU DOMMAGES SONT PRÉVISIBLES. EN AUCUN CAS USSC, OU SES OFFICIERS,
DIRIGEANTS, OU AGENTS NE SERONT RESPONSABLES DE TOUTES PERTES DIRECTES, COÛTS OU DOMMAGES EXCÉDANT
LE PRIX D’ACHAT DU PRODUIT.
CERTAINES JURIDICTIONS N’AUTORISENT PAS L’EXCLUSION OU LA LIMITATION DES DOMMAGES FORTUITS OU
CONSÉCUTIFS, ET LES PRÉCÉDENTES RESTRICTIONS, OU EXCLUSIONS POURRAIENT NE PAS S’APPLIQUER À L’ACHETEUR.
Cette garantie limitée vous donne des droits légaux spéciques et vous pourriez avoir d’autres droits qui
varieront d’une juridiction à l’autre. Les dispositions de la Convention des Nations Unies sur les contrats de vente
de marchandises ne s'appliquent pas à cette garantie limitée ou à la vente de produits couverts par cette
garantie limitée.
***AVIS IMPORTANT***
- NE PAS retourner à l’endroit de l’achat -
Pour les problèmes de service à la clientèle et de garantie, contactez le service client
13
Date________________________
Ingénieur Nom:_____________________________________
Service de 01
Refustratuib No.:____________________________________
Company__________________________________________
N ° de téléphone.___________________________________
Poêle Inspecté: Cheminée Swept:
Arcles Remplacé:__________________________________
Date________________________
Ingénieur Nom:_____________________________________
Service de 02
Refustratuib No.:____________________________________
Company__________________________________________
N ° de téléphone.___________________________________
Poêle Inspecté: Cheminée Swept:
Arcles Remplacé:__________________________________
Date________________________
Ingénieur Nom:_____________________________________
Service de 03
Refustratuib No.:____________________________________
Company__________________________________________
N ° de téléphone.___________________________________
Poêle Inspecté: Cheminée Swept:
Arcles Remplacé:__________________________________
Date________________________
Ingénieur Nom:_____________________________________
Service de 04
Refustratuib No.:____________________________________
Company__________________________________________
N ° de téléphone.___________________________________
Poêle Inspecté: Cheminée Swept:
Arcles Remplacé:__________________________________
Date________________________
Ingénieur Nom:_____________________________________
Service de 05
Refustratuib No.:____________________________________
Company__________________________________________
N ° de téléphone.___________________________________
Poêle Inspecté: Cheminée Swept:
Arcles Remplacé:__________________________________
Date________________________
Ingénieur Nom:_____________________________________
Service de 06
Refustratuib No.:____________________________________
Company__________________________________________
N ° de téléphone.___________________________________
Poêle Inspecté: Cheminée Swept:
Arcles Remplacé:__________________________________
Date________________________
Ingénieur Nom:_____________________________________
Service de 07
Refustratuib No.:____________________________________
Company__________________________________________
N ° de téléphone.___________________________________
Poêle Inspecté: Cheminée Swept:
Arcles Remplacé:__________________________________
Date________________________
Ingénieur Nom:_____________________________________
Service de 08
Refustratuib No.:____________________________________
Company__________________________________________
N ° de téléphone.___________________________________
Poêle Inspecté: Cheminée Swept:
Arcles Remplacé:__________________________________
Il est recommandé que votre système de chauffage est desservi régulièrement et que le Service Interval enregistrement
approprié est terminée.
Fournisseur de services:
Avant de terminer l'enregistrement de service approprié ci-dessous, s'il vous plaît vous assurer que vous avez effectué le service tel
que décrit dans le les instructions du fabricant. Toujours utiliser pièce de rechange indiquée par le fabricant lors de remplacement
est nécessaire.
Fiche d'entretien
12
Remarque
11
1
2
4
5
3
Liste Des Pieces
Clé Partie Description Qté.
1 892958 Réecteur 1
2 892959 Écran d'émetteur 1
3 892960 Garde 1
4 81299 Brûleur 1
5 81300 Régulateur 1
ATTENTION: An de conserver la garantie, les composants doivent être remplacés à l’aide des pièces
d’origine du fabricant achetées auprès de votre revendeur ou directement auprès du fabricant de
l’appareil. L’utilisation de composants tiers annulera la garantie.
Pour l’assistance technique: téléphone: (800) 750-2723
10
ENTRE LES UTILISATIONS
Tournez le bouton de commande sur OFF.
Ouvrez la porte et déconnectez la bouteille.
Entreposez cette unité dans un endroit qui est à l'abri des intempéries (comme la pluie, le grésil, la grêle,
la neige, la poussière et les débris).
Au besoin, couvrez l'unité pour protéger les surfaces extérieures et empêcher les accumulations dans les
conduits d'air.
PENDANT LES PÉRIODES D'INACTIVITÉ PROLONGÉE OU LORS DU TRANSPORT
Tournez le bouton de commande sur OFF.
Débranchez la bouteille de GPL et déplacez-vous dans un endroit sûr et bien ventilé à l'extérieur. NE PAS
stocker dans un endroit qui dépasse 125 degrés F.
La bouteille de propane doit être entreposée à l'extérieur dans un endroit bien ventilé. Il doit être hors de
portée des enfants et non dans un immeuble, un garage ou tout autre endroit fermé.
Entreposez l'appareil de chauffage verticalement dans une zone à l'abri d'un contact direct avec les
intempéries (pluie, grésil, grêle, neige et débris). Au besoin, couvrez l'unité pour protéger les surfaces
extérieures et empêcher les accumulations dans les conduits d'air.
REMARQUE : Attendez jusqu'à ce que l'unité soit froide avant de la recouvrir.
ENTREPOSAGE
Dépannage
PROBLÈME CAUSE PROBABLE SOLUTION
La veilleuse ne
s'allume pas
La valve de gaz peut être fermée Actionner la vanne de gaz
RÉSERVOIR À CARBURANT vide Remplissez le réservoir de GPL
Orice bloqué Nettoyer ou remplacer l'orice
Air dans le système d'alimentation Purger l'air situé des lignes
Connexion lâche Vériez tous les raccords
La veilleuse ne
reste pas allumé
Impuretés autour de la veilleuse Nettoyez les surfaces sales
Connexion lâche Resserrer les connexions
Le thermocouple est mauvais Remplacer le thermocouple
Fuite de gaz dans la ligne Vériez les connexions
Manque de pression de carburant
Le réservoir de carburant est
presque vide
Le brûleur ne
s'allume pas
La pression est faible
Le réservoir de carburant est
presque vide
Orice bloqué Enlever, nettoyer et remplacer
La vanne de contrôle n'est pas allumée Tourner la vanne sur la position "ON"
Le thermocouple est mauvais Remplacer le thermocouple
L'ensemble de la veilleuse est plié ou non au
bon endroit
Placez le pilote dans la bonne position
et réessayez
ATTENTION : An de conserver la garantie, les composants doivent être remplacés à l'aide des pièces d'origine
du fabricant achetées auprès de votre revendeur ou directement auprès du fabricant de l'appareil. L'utilisation
de composantes provenant de tiers annulera la garantie.
Contactez l'assistance au : téléphone : (800) 750-2723
9
VÉRIFIEZ L'ENSEMBLE DES TUYAUX
L'installation doit être effectuée uniquement par des personnes compétentes et doit être conforme aux codes
d'usages pertinents.
Avant l'utilisation, vériez s'il y a des pièces endommagées comme des tuyaux, des régulateurs, une veilleuse ou
un brûleur. Ne remplacez ou ne substituez jamais le régulateur par un autre que celui recommandé par l'usine.
VÉRIFIEZ LA FLAMME
La forme de la amme sur la grille de l'émetteur doit être vériée visuellement chaque fois que le chauffage
est actionné. Normalement, la amme du brûleur est bleue, mais une petite amme jaune est acceptable. Si les
ammes dépassent la grille de l'émetteur ou si des points noirs se sont accumulés sur la grille de l'émetteur ou sur
le réecteur, éteignez immédiatement le radiateur. L'appareil de chauffage ne doit plus être utilisé avant d'avoir
été entretenu et réparé par un technicien du gaz qualié.
NETTOYAGE
Pour proter des années de performance exceptionnelle de votre appareil de chauffage, assurez-vous
d'effectuer régulièrement les activités de maintenance suivantes :
1. Gardez les surfaces extérieures propres :
• Utilisez de l'eau tiède savonneuse pour le nettoyage. N'utilisez jamais des produits de nettoyage
inammables ou corrosifs.
• Pendant le lavage de votre appareil, veillez à ce que la zone autour du brûleur et de la veilleuse soit
toujours sèche. Si le contrôle du gaz est exposé à l'eau de quelque façon que ce soit : n'essayez pas de
l'utiliser. Il doit être remplacé.
2. Le ux d'air ne doit pas être obstrué. Maintenez les commandes, le brûleur et les passages d'air de circulation
propres. Les signes d'une obstruction éventuelle sont :
Une odeur de gaz avec un bout de amme très jaune.
• L'unité n'atteint PAS les températures souhaitées.
• La lueur du chauffage est excessivement inégale.
• Le chauffage fait des bruits de claquement.
3. Les araignées et les insectes peuvent se nicher dans le brûleur ou les orices. Cette situation dangereuse
peut endommager le chauffage et le rendre impropre à l'utilisation. Nettoyez les trous du brûleur à l'aide
d'un cure-pipe robuste. L'air comprimé peut aider à dégager les petites particules.
4. Les dépôts de carbone peuvent provoquer des risques d'incendie. Nettoyez le dôme et le chapeau du
brûleur avec de l'eau tiède savonneuse si des dépôts de carbone se développent.
AVERTISSEMENT :
Cet appareil nécessite un régulateur. Vériez auprès de votre fournisseur de gaz et / ou fournisseur de produits.
AVERTISSEMENT :
POUR VOTRE SÉCURITÉ
NE touchez PAS ou NE déplacez PAS le chauffage pendant au moins 45 minutes après l'utilisation. Laissez
tous les éléments du brûleur refroidir avant de le manipuler.
REMARQUE : Dans un environnement où l'air est salé (comme près de l'océan), la corrosion peut se produire
plus rapidement qu'à la normale.
Recherchez régulièrement des signes de corrosion puis effectuez les retouches nécessaires sans délai.
Entretien
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

HomComfort HCPHTTM Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues